C-FIX 1.6.0.

1925
Database version
2014.9.1.9.30
Date
20/10/2014
Indigo, Bali

Mr. Safety , Bersama Bangun Persada


Perkantoran Mega Sunter D10-D11
14350 Jakarta, Indonesia
info@mrsafetygroup.com
www.mrsafetygroup.com

Comment
Used Anchor: FTRS M20x260mm + FIS VT 380C (170 mm embedment depth)

Design Specications
Anchor
Anchor system
Injection resin
Fixing element
Anchorage depth

scher Injection system FIS VT


FIS VT 300 T
Threaded rod RG M 20 x 260, zinc plated steel,
property class 5.8
170 mm

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including


partial safety factor for the load)

Not drawn to scale

Input data
Design method
Base material
Concrete condition
Temperature range
Reinforcement
Drilling method
Installation type
Annular gap
Type of loading
Base plate location
Base plate geometry

Design method ENSO Bonded


Normal weight concrete, C25/30, EN 206
Non-cracked, dry hole
24 C long term temperature, 40 C short term temperature
Normal or no reinforcement. No edge reinforcement
Carbide drilling
Push-through installation
Annular gap lled
Static or quasi-static
Base plate ush installed on base material
400 mm x 800 mm x 8 mm
The input values and the design results should be checked against local valid standards and approvals.

Page 1

C-FIX 1.6.0.1925
Database version
2014.9.1.9.30
Date
20/10/2014
Indigo, Bali

Prole type

None

Design actions *
NSd
kN

VSd,x
kN

VSd,y
kN

MSd,x
kNm

MSd,y
kNm

MT,Sd
kNm

0.00

75.00

0.00

0.00

0.00

0.00

* The required partial safety factors for actions are included

Resulting anchor forces


Tensile action
kN

Shear Action
kN

Shear Action x
kN

Shear Action y
kN

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

0.00

9.38

9.38

0.00

Anchor no.

Force:

Tension

Compression

max. concrete compressive strain :


max. concrete compressive stress :
Resulting tensile actions :
Resulting compression actions :

N/mm
kN , X/Y position ( / )
kN , X/Y position ( / )

Resistance to shear loads


Proof

Action
kN

Steel failure without lever arm *

Capacity
kN

Utilisation V
%
19.2

9.38

48.80

Concrete pry-out failure

75.00

331.97

22.6

Concrete edge failure

75.00

75.97

98.7

* Most unfavourable anchor

Steel failure without lever arm


(VRd,s)

VRk,s
kN

Ms

VRd,s
kN

VSd
kN

Vs
%

61.00

1.25

48.80

9.38

19.2

Concrete pry-out failure


(VRd,cp)

The input values and the design results should be checked against local valid standards and approvals.

Page 2

C-FIX 1.6.0.1925
Database version
2014.9.1.9.30
Date
20/10/2014
Indigo, Bali

Equation
(5.7a)
Equation (5.3)

Equation
(5.3a)

Equation
(5.3c)

Equation
(5.3d)
Equation
(5.3e)

VRk,cp
kN

Ms

VRd,cp
kN

VSd
kN

V,cp
%

497.95

1.50

331.97

75.00

22.6

Concrete edge failure


(VRd,c)

Equation (5.8)

Equation
(5.8a)

Equation
(5.8b/c)

Equation
(5.8e)

Equation
(5.8f)

Equation
(10.2-5f)

Equation
(5.8h)

The input values and the design results should be checked against local valid standards and approvals.

Page 3

C-FIX 1.6.0.1925
Database version
2014.9.1.9.30
Date
20/10/2014
Indigo, Bali

VRk,c
kN

Mc

VRd,c
kN

VSd
kN

V,c
%

113.96

1.50

75.97

75.00

98.7

Resistance to combined tensile and shear loads


Proof successful

Equation (5.9b)

Information concerning the anchor plate


Base plate details
Plate thickness specied by user without proof
Prole type

t = 8 mm
None

Technical remarks
If the edge distance of an anchor is smaller than the characteristic edge distance Ccr,N=255 mm (design method A),
please see the appropriate sections of the ETA and ETAG.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and the
serviceability limit state; for this purpose, the normal verications shall be carried out under due consideration of the actions
introduced by the anchors. For these verications the additional provisions given in the current design method shall be taken
into account.

The input values and the design results should be checked against local valid standards and approvals.

Page 4

C-FIX 1.6.0.1925
Database version
2014.9.1.9.30
Date
20/10/2014
Indigo, Bali

Installation data
Anchor
Anchor system
Injection resin

scher Injection system FIS VT


FIS VT 300 T (other cartridge sizes
available)
Threaded rod RG M 20 x 260, zinc
plated steel, property class 5.8

Fixing element

Accessory

FIS Easy mixer


Dispenser FIS DM S
Compressed-air cleaning tool
compressed air (oil-free), min. 6 bar
SDS chuck with internal thread
Hammer drill bit SDS Max IV
24/200/320

Art.-No. 518863
Art.-No. 50260

Art.-No. 61223
Art.-No. 511118
Art.-No. 93286
By job site.
Art.-No. 511961
Art.-No. 504228

Installation details
Thread diameter
Drill hole diameter
Drill hole depth
Anchorage depth
Drilling method
Drill hole cleaning

M 20
d0 = 24 mm
h2 = 178 mm
hef = 170 mm
Carbide drilling
4 times blowing,
4 times brushing,
4 times blowing
required activities according the given
instruction in the approval
Installation type
Push-through installation
Annular gap
Annular gap lled
Maximum torque
Tinst,max 120.0 Nm
Socket size
30 mm
Base plate thickness
t = 8 mm
Total xing thickness
tx = 8 mm
Volume of resin per drill hole 28 ml/14 scale divisions

Base plate details


Base plate material
Not available
Base plate thickness
t = 8 mm
Clearance hole in base plate df=26 mm

Attachment
Prole type

None

The input values and the design results should be checked against local valid standards and approvals.

Page 5

C-FIX 1.6.0.1925
Database version
2014.9.1.9.30
Date
20/10/2014
Indigo, Bali

Anchor coordinates
Anchor no.

x
mm

y
mm

-100

275

100

275

-100

75

100

75

-100

-75

100

-75

-100

-275

100

-275