Sie sind auf Seite 1von 2

GSM-Control SMS software

The most easy and low cost way to make your PC application wireless
makes a PC as 2-way communication center with GSMmodem using standard SMS service
interfaces devices with GSM-modems, users with phones
and existing PC applications together
configures, transfers, reports, secures and interfaces the
applications
M2M automation, info systems, field personnel guidance,
customer service etc.
open interfaces to other PC applications: DDE, OPC and
SQL
alarms, reporting, metering etc.
The GSM-Control runs on a PC and accesses HMI and other
Windows applications or directly field devices by using DDE
or OPC interfaces. GSM-Control also supports the reading/
writing of data from/to SQL databases. The remote
control is based on GSM SMS messages twodirection communication, where the GSMmodem is connected to the computers
standard (RS-232) serial port and GSM
cellular phone (remote GSM phone) is
used by remote operator(s). Also the
communication between two GSMmodems is supported, i.e. remote
GSM-modems can be used instead
of remote GSM phone.
n user interfaces
The data exchange through
n PCs, PDAs
GSM-Control can be initiated
n phones
both from GSM and Windows
environments:

1. From GSM environment - by


sending SMS message to GSMControl, where the received
message is checked and
processed according the GSMControl current configuration.
The received SMS message
can contain some data to be
transferred via DDE, OPC or SQL
from GSM-Control to other MS Windows
applications (e.g. to PC operator interface
applications or field devices through appropriate
communication servers) or databases. This
SMS message received can have the corresponding
response message configured (also possibly containing
data values obtained by via DDE, OPC or SQL) - in this case
GSM-Control will respond with SMS message to the sender.
2. From PC Windows environment - when some alarm or
event occurs in MS Windows application (e.g. in PC operator
interface application or directly in the field device) and
the corresponding alarm or event condition is specified
in GSM-Control. In this case GSM-Control will send the
correspondingly configured SMS message (possibly
containing also some data obtained via DDE, OPC or SQL) to
remote GSM operator or device linked to this alarm or event
condition. The receiver of such SMS message can respond to

n customer applications
n Excel, SQL etc.
n SCADA etc.
n info systems

GSM-Control
SMS

PC with GSM-modem

n devices with GSM-modems


n automation, PLCs
n service automates

GSM-Control - for example, send some acknowledgment SMS


message possibly containing some data for delivery via DDE,
OPC or SQL.
Moreover, it is possible to send (manually or automatically
through DDE or OPC) any pre-configured text message
(standard 1-way messages) from GSM-Control to remote
GSM operator or device. The SMS messages also can
be received from any (not configured) phone number (so
called ANYUSER feature) and correspondingly replied with
information depending on contents of received message.
www.klinkmann.com

The GSM-Control can be used on internet - it is possible to


send SMS messages by e-mails from GSM-Control to GSM
network and to receive SMS messages as e-mails from
GSM network. In this case GSM-Control may run without
GSM-modem connected - modem is replaced by e-mail
connection.

DDE or OPC Server (or DDE or OPC Client in case of direct


sending/receiving of SMS Messages via GSM-Control). The
GSM-Control has extended functions and support to SCADA
systems incl. Wonderware InTouch (for HMI) and I/O Servers
(for field interfacing) developed with Wonderware I/O Servers
Development Toolkit.

The GSM-Control may be accessed by any Microsoft


Windows (NT, 2000, XP, 95/98) program working as a

PC
Customer applications
Excel, SQL, SCADA etc.
SMS

DDE/OPC interface

GSM-Control Configuration Program allows quickly and easily


link SMS messages with DDE, OPC and SQL items

I/O
devices

GSM-Control
software
GSM-modem

GSM-Control reports all events and


communication traffic as well as result
of GSM-modem initialization

New features in GSM-Control version 4.0


The new release of GSM-Control (version 4.0) has completely
modified GSM-Control Configuration Program for user
friendly and convenient use. Also the following additional
new features are added:
SMS Messages to be sent from GSM-Control to remote
GSM operator or device now are called SEND messages
SMS messages which can be received by GSM-Control
from remote GSM operator or device now are called
RECEIVE messages
Both DDE and OPC interfaces are supported in the same
GSM-Control Communication Program

Each DDE, OPC or SQL item can have Description field


where item content can be freely described
Users can be configured to receive SMS message only,
SMS message and additional voice call, voice call only
(instead of SMS message)
Days of week added to User Time Shifts
Alarm messages can have corresponding Alarm
Acknowledgment messages
Alarm messages (as well as Alarm Acknowledgment
messages) can contain additional DDE, OPC or SQL items
One SMS message can contain items from several
different SQL connections (queries)

ORDERING INFORMATION
Description

Order Number

GSM-Control v4.14 SMS Center Software for PC,


3phone/modem numbers, sw only

PR000673

GSM-Control v4.14 SMS Center Software for PC,


unlimited, sw only

PR00067

Hardware Kit: TC35T GSM-modem, antenna, power


supply, modem cable to interface PC to GSM network

PC GSM SET

www.klinkmann.com

Other wireless KLINKMANN sofware


GSM-Dial, conventional data connections
with GSM-data
GPRS/WAP-Tool, 2-way queries to SQL
database over WAP

Das könnte Ihnen auch gefallen