Operation Manual
(Java version)
NEC Corporation
Copyright © 2009
ROI-S07012
TABLE OF CONTENTS
-i-
ROI-S07012
- ii -
ROI-S07012
Document Warranty
1. The information contained in this document is subject to change without prior notice.
2. The NetCfgToolj screen figures in this manual are only examples. Screens will vary according to
equipment configuration, operation modes, setting parameters, NetCfgToolj application program
version, etc. Screens contained in this manual are current at publication, however, they may
differ from actual screens on your NetCfgToolj.
- 1-
ROI-S07012
1.1 Purpose
This document illustrates the use of the NetCfgToolj. The explanation focuses on the common
functions of the NetCfgToolj and therefore is for general-purpose operational use. Moreover, the
NEC PNMS is also briefly described to provide users with an overall understanding of the NEC
PASOLINK NMS.
- 2-
ROI-S07012
- 3-
ROI-S07012
2 NetCfgToolj Operation
Common
Menu Bar
Common
Tool Bar
- 4-
ROI-S07012
File
New
Open
Save
Save As Setting
Clear
Print Area
Print
Exit Application
Edit
Undo
Redo
Main Menu
Pasolink V3
File Copy
Paste Pasolink V4
Edit
Delete Pasolink Mx
Network
Pasolink-S
Tools
Highlighting ON MIU (Line Concentrator)
Help
Highlighting OFF MIU (HOP)
Pasolink+ STM-1
Switch to PASOLINK NEO (Hop) mode Pasolink+ STM-0
Pasolink+ PDH
Select All PASOLINK NEO (Hop)
PASOLINK NEO (1NE)
PASOLINK NEO CPV (Hop)
Select
Add Network Element PASOLINK NEO CPV (1NE)
Add BB Line PASOLINK NEO NODAL
PASOLINK NEO/a
Add DSC/SV Link
PASOLINK NEO HP (Hop)
Network Element Type 5000S (Hop)
5000S (1NE)
Properties
Tools
Create Configuration
Create Configuration (All Networks)
Network Element List
Help NetConfigToolj.pdf
Help
About NetConfigToolj
- 5-
ROI-S07012
- 6-
ROI-S07012
- 7-
ROI-S07012
1. Click on Network Æ
Properties from the main menu
or right click anywhere in the
current Network window to
open the Network Properties
window.
2. Enter the desired name for this
workspace/network in the
Network Name box.
3. Click on [OK] button to save the
new setting.
- 8-
ROI-S07012
NOTE: *The maximum number of NE’s per CPMC network is 416 NE’s regardless to whether
more than 416 IP addresses are assigned to the network.
* The maximum number of NE’s per Root NE network is 500.
This number is calculated by following formula.
Maximum number of NE’s per Root NE network
=[Maximum number of subnet per Root NE network] X [Maximum number of
NE’s per subnet]
The ensuing window, Network Address window, allows you to modify the default subnet by
either changing the Network Address or the Subnet mask to be used by the selected
network. You can increase or decrease the allocated IP address on the selected network
by modifying the subnet mask and the network address in this window. (Refer to
Appendix B: Subnets to see the available subnets in the managed network.)
In the example shown below, where the network
address is 172.18.0.64 with subnet mask
255.255.255.192 given to the selected network,
NetCfgToolj will allocate the IP address
172.18.0.65-126 to this network. Note that in this
example 62 IP addresses were assigned. Another
as the network address (172.18.0.64) and
another as the broadcast address (172.18.0.127). Click on [OK] to save the new subnet.
When the [Add] button was clicked in step.3, the
ensuing window enables you to define another
subnet that will be added to the existing subnet.
Click on [Add] button to save the new subnet.
(NOTE: The maximum number of network
addresses and subnet mask settings that can be
registered is 5.)
NOTE: Since IP addresses from 172.17.240.0 thru 172.17.255.255 are internally reserved
IP Addresses, those can not be assigned to any network as its Network Address.
- 9-
ROI-S07012
The NetCfgToolj supports Pasolink V3, Pasolink V4, Pasolink-S, MIU, Pasolink Mx, Pasolink+,
Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge NE), Pasolink+ PDH (Bridge NE), PASOLINK
NEO, PASOLINK NEO CPV, PASOLINK NEO NODAL, PASOLINK NEO/a, PASOLINK NEO HP
and 5000S network configurations. Therefore a network element can either be a Pasolink V3,
Pasolink V4, Pasolink S, MIU, Pasolink Mx, Pasolink+, Pasolink Mx (Bridge NE), Pasolink+
STM-1 (Bridge NE), Pasolink+ PDH (Bridge NE), PASOLINK NEO, PASOLINK NEO CPV,
PASOLINK NEO/a, PASOLINK NEO HP or 5000S. Note that the configuration is the same for
Pasolink-S, Pasolink V3 and Pasolink V4 or Pasolink Mx and Pasolink+.
To add a new NE:
1. Click on icon in the tool bar or click on EditÆ Network Element Type from the
main menu to add a network element. Select the type of NE that you would like to add
from the pull-down list. Pasolink V3 is selected by default.
2. Click on the spot in the current workspace where you wish to add the NE.
3. Arrange the newly added hop according to desired position in the workspace. The NEs
can be moved around the workspace by clicking on it and dragging it to the desired
location in the workspace
- 10-
ROI-S07012
1. Click on the icon in the tool bar or click on EditÆ Add BB Line from the main menu.
2. Click on one of the NE to be connected. Then click on the other NE to be connected by
back-to-back line (cable) to the previously selected NE. Refer to the example given below.
1. Click on the icon in the tool bar or click on EditÆ Add DSC/SV Line from the
main menu.
2. Click on one of the NE to be connected. Then click on the other NE to be connected by
DSC/SV line (radio) to the previously selected NE. Refer to the example given below.
- 11-
ROI-S07012
The NMS back-to-back connection between NE’s varies according to the type of NE’s connected,
speed, synchronization, the port used and the type of protocol used. The NetCfgToolj uses
color-coded lines to allow the network designer to distinguish the various types of connection.
The following lists the color codes used by the NetCfgToolj to represent the different
back-to-back connection types.
Black: represents the common RS-485/RS-232C/9600bps/ASYNC multi-drop line
between Pasolink, Line Concentrator, MIU and Pasolink-S NE’s.
Red: represents the 64kbps/RS-422/SYNC connections between NE1 and NE1 of
Pasolink Mx/Pasolink+/Pasolink Mx (Bridge NE)/Pasolink+ STM-1 (Bridge NE) /Pasolink+
PDH (Bridge NE) NE’s.
Violet: represents the RS485/19200bps/ASYNC connections NE2 and NE1 of Pasolink
Mx/Pasolink+ NE’s or RS485/9600bps/ASYNC connection between Pasolink
V3/PasolinkV4/Pasolink-S/MIU and PASOLINK NEO/PASOLINK NEO CPV/PASOLINK
NEO NODAL/PASOLINK NEO/a /PASOLINK NEO HP/5000S/Pasolink Mx/Pasolink+ NE’s
or RS485/19200bps/ASYNC connection between PASOLINK NEO/PASOLINK NEO
CPV/PASOLINK NEO NODAL/PASOLINK NEO/a /PASOLINK NEO HP/5000S/Pasolink
Mx/Pasolink+ and Pasolink V3/PasolinkV4/Pasolink-S/MIU NE’s.
Blue: represents the LAN (Ethernet) back-to-back connection between Pasolink
Mx/Pasolink+/Pasolink Mx (Bridge NE)/Pasolink+ STM-1 (Bridge NE) /Pasolink+ PDH
(Bridge NE) /PASOLINK NEO/PASOLINK NEO CPV/PASOLINK NEO NODAL/
PASOLINK NEO/a /PASOLINK NEO HP/5000S NE’s.
- 12-
ROI-S07012
To remove an NE:
To remove a line:
- 13-
ROI-S07012
The Pasolink Mx, Pasolink+ STM-1, Pasolink+ PDH NE can be Bridge NE mode enabled.
To enable Bridge NE mode:
NOTE: This changes all Pasolink Mx, Pasolink+STM-1, and Pasolink+PDH that exist in the
workspace to NE for Bridge NE at once. Therefore, it is impossible to only enable some
NEs for Bridge NE mode. Moreover, when Pasolink
V3/PasolinkV4/Pasolink-S/MIU/Pasolink+STM-0 NEs coexist in the workspace, they are
unalterable. Furthermore, the connection status of an NE automatically changes to blue
(from violet) when it is Bridge NE enabled.
- 14-
ROI-S07012
Before After
NOTE: The connection status of an NE automatically changes to blue (from violet) after it is
Bridge NE enabled.
- 15-
ROI-S07012
Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge NE), Pasolink+ PDH (Bridge NE) NEs can be
changed to PASOLINK NEO. There are two ways in which this can be done.
Case 1: to change / enable via Main Menu
To change to PASOLINK NEO type NE:
- 16-
ROI-S07012
Parameter Definition
Equipment Type Specifies the type of equipment of the target NE. (Pasolink V3 or
Pasolink V4 or Pasolink-S)
Network Element Name Defines the name of the NE. Maximum number of characters
possible is 32.
Area Name Defines the name of the area where the NE is located. (Optional).
Maximum number of characters possible is 32.
Note Optional note used to describe the selected NE. Maximum
number of characters possible is 100.
PMC Type Defines the role of the NE in the network. It can either be a CPM,
RPM or Sub-CPM
Name Position Defines the position where the NE Name will be displayed in
relation to the NE bitmap in the workspace
Antenna Direction Defines the direction where the NE is facing in the workspace.
- 17-
ROI-S07012
b) SCPMC Network
- 18-
ROI-S07012
Parameter Definition
Assign IP Address manually By selecting this check box you can change the IP Address
the DPU and NMS ports.
Assign Subnet Mask manually By selecting this check box you can change Subnet Mask of
both DPU and NMS ports.
DPU Port IP Address Defines the assigned IP Address of the selected NE.
Subnet Mask Defines which part of the PMC IP Address will be masked and
defined as subnet. This also, defines what class of IP
addressing is used. (i.e. Class A, Class B, Class C, etc.). Only
3 subnet masks are allowed: 16 (255.255.255.240) default, 8
(255.255.255.248) or 4 (255.255.255.252).
Subnet Name Defines the name of the DPU Port sub-network.
Opposite Network Defines the IP Address of the opposite station
Element
NMS Port IP Address Defines the assigned IP Address of the selected NE.
Subnet Mask Defines which part of the PMC IP Address will be masked and
defined as subnet. This also, defines what class of IP
addressing is used. (i.e. Class A, Class B, Class C, etc.). Only
3 subnet masks are allowed: 16 (255.255.255.240) default, 8
(255.255.255.248) or 4 (255.255.255.252).
Subnet Name Defines the name of the NMS Port sub-network.
- 19-
ROI-S07012
2.9.9.3 Editing HDLC Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S
To change the HDLC Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:
Table 2.3 HDLC Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S
Parameter Definition
Master Timeout The time in seconds after which the PMC will assume that it has lost
the communication link with the master PMC.
Master Interval The interval in seconds at which the PMC will check for the polling
signal from the master PMC
Slave Timeout The time in seconds after which the master PMC will assume that
the link with its slave PMC is lost.
UA Timeout The time period that the master PMC will wait for response for
SNRM.
Auto Role Change If enabled, the PMC will automatically change its function from slave
to master PMC, once it has lost its link with the master PMC in the
upper network. It will also automatically change back to slave once
the link with the master is restored. This is normally set to
"Enable".
Role Change Timeout The elapsed time in seconds that the slave PM card waits for the
polling message from the CPMC before it assumes the role of the
CPMC.
High BER DPU Inhibit If High BER DPU Inhibit is set to Enable, Hi BER alarm is inhibited.
Then it will not be activated even if DPU port receives deficient data.
- 20-
ROI-S07012
2.9.9.4 Editing Port Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S
To change the Port Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:
1. Right click on the selected NE to display the context menu.
(Or double click on the selected NE to open the NE Properties window.)
2. Click on Properties in the context menu to open the NE Properties window.
3. The NE Properties window will appear. Click on Port category to display the Port
Configuration Parameters window.
4. The DPU Port and NMS Port baud rates can be changed via this window. The definitions
of these parameters are listed in Table 2.4
Table 2.4 Port Configuration Parameters of Pasolink V3, Pasolink V4 and Pasolink-S
Parameter Definition
DPU Port Action Mode Defines the role of the DPU Port of NE. * The possible modes
are Master, Slave, and Repeater.
Baud Rate Defines the speed of the DPU Port in bits-per-second (bps).
NMS Port Action Mode Defines the role of the NMS Port of NE. * The possible modes
are Master, Slave, Repeater and Disabled.
Baud Rate Defines the speed of the NMS Port in bits-per-second (bps).
Mode Defines the wiring (interface) protocol used
* This item will not be defined until the Create Configuration process.
- 21-
ROI-S07012
Parameter Definition
Auto Set Time If enabled, the PMC automatically sets its time to match that of the
PNMS or the CPMC.
Set Time Interval The time interval before the PMC periodically synchronizes its time
to the PNMS or CPMC.
Auto Write Back If enabled, the PMC automatically writes the Log data and PM data
to the Flash ROM.
Write Back Interval The time interval at which the PMC saves Log and PM data in the
Flash ROM.
- 22-
ROI-S07012
2.9.9.6 Editing PNMS Parameters (for CPMC only) of Pasolink V3, Pasolink V4 and Pasolink-S
This parameter is relevant only to the NE designated as CPMC.
To change the PNMS Parameters of Pasolink V3, Pasolink V4 and Pasolink-S:
1. Right click on the selected NE to display the context menu.
(Or double click on the selected NE to open the NE Properties window.)
2. Click on Properties in the context menu to open the NE Properties window.
3. The NE Properties window will appear. Click on PNMS category to display the PNMS
Parameters window.
4. In this window, the IP address and subnet mask information of the PNMS port are
defined. LAN or RS232/RS422 is selected as the connection mode and the
corresponding parameters in the ensuing box are activated. These parameters are
defined in Table 2.6.
- 23-
ROI-S07012
Parameter Definition
PNMS Connection Defines the type of connection used by the CPMC to the
PNMS. The CPMC can connect to the PNMS PC /
Workstation either thru RS232C/RS422 (Dial-Up) or LAN (IP)
connection.
Pasolink V3, Pasolink V4: RS232C/RS422/LAN
Pasolink-S: RS232C/RS422
LAN IP Address IP address of LAN port of the target NE.
Subnet Mask Subnet mask of LAN port mentioned above.
Default Gateway IP address of Default Gateway.
Normally the IP address of the PNMS PC.
RS232C/RS422 Connection Type Defines the type of connection used by the CPMC to the
PNMS. The CPMC can connect to the PNMS PC either thru
Direct connection (Dial-Up) or Router connection.
IP Address When the RS232C or RS422 PNMS connection is selected,
the input fields are activated. The IP address is the one that is
used by the RS232C or RS422 port of the Pasolink IDU.
Subnet Mask Subnet Mask of the RS232C or RS422 port mentioned above.
- 24-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: Pasolink Mx, Pasolink+ STM-1,
STM-0 and PDH.
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remark on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE, Branch NE or
Normal NE.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 25-
ROI-S07012
4. In this window, the IP Address information of the Radio/NE1 port is defined. If the CTRL
Type from the General category is set to “Root NE” or “Normal NE”, the IP address under
“Bridge” is used. On the other hand, if set to “Branch NE”, the IP addresses under
“Separate Interface” are used. The definitions of these parameters are listed in Table 2.8.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in “Assign IP
Address manually” check box or “Assign Subnet Mask manually” check box.
- 26-
ROI-S07012
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is
selected, user can modify IP Address (Radio/NE1).
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask (Radio/NE1).
Network Bridge IP Address IP address of the Bridge or LAN port of the selected NE.
Bridge Subnet Mask Subnet mask of the LAN port.
Bridge Subnet Name Defines the name of the Bridge Port sub-network.
IP Address for Radio IP address of the DPU/Radio port.
Subnet Mask for Radio Subnet mask of the DPU/Radio port.
Subnet Name for Radio Defines the name of the Radio port sub-network.
IP Address for NE1 IP address of NE1 port.
Subnet Mask for NE1 Subnet mask of NE1 port.
Subnet Name for NE1 Defines the name of the NE1 port sub-network.
Port Setting Radio /Speed Speed of the DPU port of the selected NE.
Radio /Opposite IP IP address of the opposite NE (DPU port).
Address
NE1 /Speed Speed of the NE1 port of the target NE.
NE1 /Mode The HDLC mode of NE1 port. Enabled only when NE1
(64000 bps is used). The possible modes are Master,
Slave and Disabled.
- 27-
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by NE2. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of NE2.
Subnet Mask Subnet mask of NE2 port.
Speed Speed of NE2 port.
HDLC Mode Specifies if the NE2 port is used in HDLC. The NE2 port can
either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s NE2 port, if it is the last port in
the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the NE2 port
termination can be set to On or Off.
- 28-
ROI-S07012
- 29-
ROI-S07012
2.9.10.5 Editing PNMS Parameters (for Root NE only) of Pasolink Mx and Pasolink+
This parameter is relevant only to NE designated as Root NE.
To change the PNMS Parameters:
1. Right click on the selected
NE to display the context
menu.
(Or double click on the
selected NE to open the
NE Properties window.)
2. Click on Properties in the
context menu to open the
NE Properties window.
3. The NE Properties
window will appear. Click
on the PNMS category to
display the PNMS
parameters.
4. In this window, the IP
Address and subnet
mask information of the
PNMS port are defined.
The definitions of these
parameters are listed in
Table 2.10.
Parameter Definition
PNMS Connection Defines the type of connection to the PNMS used by the
Root NE. The Root NE can connect to the PNMS PC either
thru V.11 (Dial-UP) connection or LAN (IP) connection.
LAN IP Address When the Ethernet connection is selected, the LAN input
fields are activated. The IP address defines that it is used by
the IDU LAN port. However, it is only used when the LAN port
is used for connecting the PNMS
IP address of LAN port of the NE. This is only set if the
selected NE is a Root NE.
Subnet Mask Subnet mask of abovementioned LAN port.
V.11 (Default) IP Address When Dial-Up connection is selected, the V.11 input fields are
activated. The IP address defines that it is used by the V.11
port of the IDU. Note that is only used when the V.11 port is
used for PNMS connection.
Subnet Mask Subnet Mask of the V.11 port mentioned above.
Speed Connection speed for dial-up access.
- 30-
ROI-S07012
- 31-
ROI-S07012
- 32-
ROI-S07012
2.9.11 Setting NE Properties of Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge NE) and
Pasolink+ PDH (Bridge NE)
2.9.11.1 To set or modify the NE properties of Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge
NE) and Pasolink+ PDH (Bridge NE):
1. Right click on the selected NE to display the context
menu (Or double click on the selected NE to open
the NE Properties window.)
2. Click on Properties in the context menu to open the
NE Properties window.
3. The NE Properties window will be displayed as
shown below. The default view is the General category
window, which shows the current configuration.
4. In this window, NE Name, Area Name, Note, CTRL
Type, NE Name Position, and Antenna Direction can
be changed. These parameters are defined in Table
2.11.
- 33-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: Pasolink Mx (Bridge NE), Pasolink+
STM-1 (Bridge NE) and Pasolink+ PDH (Bridge NE).
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remark on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE, Root NE (Bridge),
Branch NE or Normal NE.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 34-
ROI-S07012
2.9.11.2 Editing Radio/NE1 Parameters of Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge NE)
and Pasolink+ PDH (Bridge NE)
To change the Radio/NE1/LAN Parameters:
1. Right click on the selected NE to display the context menu.
(Or double click on the selected NE to open the NE Properties window.)
2. Click on Properties in the context menu to open the NE Properties window.
3. The NE Properties window will appear. Click on the Radio/NE1/LAN category to display
the Radio/NE1/LAN port information.
a) Branch NE
b) Other
4. In this window, the IP Address information of the Radio/NE1/LAN port is defined. The
definitions of these parameters are listed in Table 2.12.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in “Assign IP
Address manually” check box or “Assign Subnet Mask manually” check box.
- 35-
ROI-S07012
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address (Radio/NE1/LAN).
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask (Radio/NE1/LAN).
Network IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
Port Setting Radio /Speed Speed of the DPU port of the selected NE
Radio /Opposite IP IP address of the opposite NE (DPU port).
Address
NE1 /Speed Speed of the NE1 port of the target NE
NE1 /Mode The HDLC mode of NE1 port. Enabled only when NE1 (64000
bps is used). The possible modes are Master, Slave and
Disabled.
- 36-
ROI-S07012
2.9.11.3 Editing PNMS Parameters (for Root NE only) of Pasolink Mx (Bridge NE), Pasolink+
STM-1 (Bridge NE) and Pasolink+ PDH (Bridge NE)
This parameter is relevant only to NE designated as Root NE.
To change the PNMS Parameters:
1. Right click on the selected NE to
display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
Parameter Definition
PNMS Connection Defines the type of connection to the PNMS used by the Root
NE. The Root NE can connect to the PNMS PC either thru
V.11 (Dial-UP) connection or LAN (IP) connection.
LAN IP Address When the Ethernet connection is selected, the LAN input
fields are activated. The IP address defines that it is used by
the IDU LAN port. However, it is only used when the LAN port
is used for connecting the PNMS
IP address of LAN port of the NE. This is only set if the
selected NE is a Root NE.
Subnet Mask Subnet mask of abovementioned LAN port.
V.11 (Default) IP Address When the Dial-Up connection is selected, the V.11 input fields
are activated. The IP address defines that it is used by the
V.11 port of the IDU. Note that is only used when the V.11
port is used for PNMS connection.
Subnet Mask Subnet Mask of the V.11 port mentioned above.
Speed Connection speed for dial-up access.
- 37-
ROI-S07012
2.9.11.4 Editing Routing Parameters of Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge NE)
and Pasolink+ PDH (Bridge NE)
This parameter is relevant only to NE designated as Root NE.
To change the Routing Parameters:
1. Right click on the selected NE to
display the context menu.
(Or double click on the selected
NE to open the NE Properties
window.)
- 38-
ROI-S07012
2.9.11.5 Editing SNTP Parameters of Pasolink Mx (Bridge NE), Pasolink+ STM-1 (Bridge NE) and
Pasolink+ PDH (Bridge NE)
Each NE support Simple Network Time Protocol, used to synchronize its internal clock to a
defined Time-server in the network.
To change the SNTP Parameters:
1. Right click on the selected NE to display the context menu.
(Or double click on the selected NE to open the NE Properties window.)
3. The NE Properties window will appear. Click on the SNTP category to display the SNTP
parameters.
a) Root NE b) Other
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval- (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 39-
ROI-S07012
2.9.11.6 Editing IP Restriction Parameters (for Root NE [Bridge] only) of Pasolink Mx (Bridge NE),
Pasolink+ STM-1 (Bridge NE) and Pasolink+ PDH (Bridge NE)
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
PNMS
Router Root NE Normal NE Normal NE Normal NE
(Bridge)
- 40-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: PASOLINK NEO.
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remarks on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs: None,
2, or 3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 41-
ROI-S07012
- 42-
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.15.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 43-
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 44-
ROI-S07012
2.9.12.4 Editing PNMS (EM1/V11) Parameters (for Root NE only) of PASOLINK NEO
When Root NE is selected as the CTRL Type, the PNMS (EM1/V11) category is displayed in the
Network
Overview:
To change the PNMS (EM1/V11) Parameters:
1. Right click on the selected NE
to display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
2. Click on Properties in the
context menu to open the NE
Properties window.
3. The NE Properties window
will appear. Click on the
PNMS (EM1/V11) category to
display the PNMS (EM1/V11)
parameters.
4. In this window, the IP Address
and subnet mask and default
gateway information of the
PNMS (EM1/V11) port are
defined. The definitions of
these parameters are listed in
Table 2.17.
Parameter Definition
PNMS Connection Defines the type of connection to the PNMS used by the
Root NE. The Root NE can connect to the PNMS PC either
thru V.11 (Dial-UP) connection or LAN (IP) connection.
LAN(Default) IP Address When the Ethernet connection is selected, the LAN input
fields are activated. The IP address defines that it is used by
the IDU LAN port. However, it is only used when the LAN port
is used for connecting the PNMS
IP address of LAN port of the NE. This is only set if the
selected NE is a Root NE.
Subnet Mask Subnet mask of abovementioned LAN port.
V.11 IP Address When the Dial-Up connection is selected, the V.11 input fields
are activated. The IP address defines that it is used by the
V.11 port of the IDU. Note that is only used when the V.11
port is used for PNMS connection.
Subnet Mask Subnet Mask of the V.11 port mentioned above.
Speed Connection speed for dial-up access.
Default Gateway Default Gateway of above mentioned EM1 (NMS) port.
Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 45-
ROI-S07012
- 46-
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 47-
ROI-S07012
2.9.12.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
PNMS
Router Root NE Normal NE Normal NE Normal NE
(Bridge)
- 48-
ROI-S07012
3. The NE Properties window will appear.The default is the General category window,
which shows the current configuration.
4. In this window, Equipment Type, NE Name, Area Name, Note, CTRL Type, Branch
NE Type, NE Name Position, and Antenna Direction can be changed. The
definitions of these parameters are listed in Table 2.18.
- 49-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: PASOLINK NEO (2-WAY) and
PASOLINK NEO (Terminal).
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remarks on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs for PASOLINK NEO (2-WAY):
None, 2, 3 or 4 branches.
The number of Branch NEs for PASOLINK NEO (Terminal):
None, 2 or 3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 50-
ROI-S07012
- 51-
ROI-S07012
e) DIR-A Port / DIR-B Port / EM2/EM1 Port f) DIR-A Port / DIR-B Port / EM2 Port / EM1 Port
--- Branch NE (3Branches) --- Branch NE (4Branches)
Port category
Port category
- 52-
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.19.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 53-
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 54-
ROI-S07012
2.9.13.4 Editing PNMS (EM1/V11) Parameters (for Root NE only) of PASOLINK NEO (1NE)
When Root NE is selected as the CTRL Type, the PNMS (EM1/V11) category is displayed in the
Network overview.
To change the PNMS (EM1/V11) Parameters:
1. Right click on the selected NE
to display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
2. Click on Properties in the
context menu to open the NE
Properties window.
3. The NE Properties window
will appear. Click on the
PNMS (EM1/V11) category to
display the PNMS (EM1/V11)
parameters.
4. In this window, the IP Address
and subnet mask and default
gateway information of the
PNMS (EM1/V11) port are
defined. The definitions of
these parameters are listed in
Table 2.21.
Parameter Definition
PNMS Connection Defines the type of connection to the PNMS used by fthe Root
NE. The Root NE can connect to the PNMS PC either thru
V.11 (Dial-UP) connection or LAN (IP) connection.
LAN (Default) IP Address When the Ethernet connection is selected, the LAN input
fields are activated. The IP address defines that it is used by
the IDU LAN port. However, it is only used when the LAN port
is used for connecting the PNMS
IP address of LAN port of the NE. This is only set if the
selected NE is a Root NE.
Subnet Mask Subnet mask of abovementioned LAN port.
V.11 IP Address When the Dial-Up connection is selected, the V.11 input fields
are activated. The IP address defines that it is used by the
V.11 port of the IDU. Note that is only used when the V.11
port is used for PNMS connection.
Subnet Mask Subnet Mask of the V.11 port mentioned above.
Speed Connection speed for dial-up access.
Default Gateway Default Gateway of above mentioned EM1 (NMS) port.
Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 55-
ROI-S07012
- 56-
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 57-
ROI-S07012
2.9.13.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO (1NE)
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
- 58-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: PASOLINK NEO CPV.
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remarks on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs: None,,
2, or 3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 59-
ROI-S07012
- 60-
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.23.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 61-
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 62-
ROI-S07012
2.9.14.4 Editing PNMS (EM1) Parameters (for Root NE only) of PASOLINK NEO CPV
When Root NE is selected as the CTRL Type, the PNMS (EM1) category is displayed in the
Network overview.
To change the PNMS (EM1) Parameters:
1. Right click on the selected NE to
display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
2. Click on Properties in the
context menu to open the NE
Properties window.
3. The NE Properties window will
appear. Click on the PNMS
(EM1) category to display the
PNMS (EM1) parameters.
4. In this window, the IP Address
and subnet mask and default
gateway information of the
PNMS (EM1) port are defined.
The definitions of these
parameters are listed in Table
2.25.
Parameter Definition
LAN IP Address The IP address defines the usage by the IDU EM1 (NMS)
port. However, it is only used when the EM1 (NMS) port is
used for connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default Gateway IP Address Default Gateway of above mentioned EM1 (NMS) port.
Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 63-
ROI-S07012
- 64-
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 65-
ROI-S07012
2.9.14.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO CPV
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
PNMS
Router Root NE Normal NE Normal NE Normal NE
(Bridge)
- 66-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment:
PASOLINK NEO CPV (Terminal).
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remarks on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs for PASOLINK NEO CPV
(Terminal): None, 2 or 3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 67-
ROI-S07012
- 68-
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.27.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 69-
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 70-
ROI-S07012
2.9.15.4 Editing PNMS (EM1) Parameters (for Root NE only) of PASOLINK NEO CPV (1NE)
When Root NE is selected as the CTRL Type, the PNMS (EM1) category is displayed in the
Network overview.
To change the PNMS (EM1) Parameters:
1. Right click on the selected NE to
display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
2. Click on Properties in the
context menu to open the NE
Properties window.
3. The NE Properties window will
appear. Click on the PNMS
(EM1) category to display the
PNMS (EM1) parameters.
4. In this window, the IP Address
and subnet mask and default
gateway information of the
PNMS (EM1) port are defined.
The definitions of these
parameters are listed in Table
2.29.
Table 2.29 PNMS (EM1) Parameters for PASOLINK NEO CPV (1NE)
Parameter Definition
LAN IP Address The IP address defines the usage by the IDU EM1 (NMS)
port. However, it is only used when the EM1 (NMS) port is
used for connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default IP Address Default Gateway of above mentioned EM1 (NMS) port.
Gateway Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 71-
ROI-S07012
- 72-
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 73-
ROI-S07012
2.9.15.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO CPV
(1NE)
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
- 74-
ROI-S07012
Parameter Definition
System Number of IDUs Defines the number of IDUs in the NODAL Group (1-4)
IP Address - Is only displayed for the respective Number of IDUs; specifically
for only those NEs in use (within the group)
- 0.0.0.0. is displayed for NEs to which an IP Address has not been
allocated yet (i.e. prior to "Create Configuration" process)
Symbol Name The name of the NODAL Group in the network. Maximum
number of characters possible is 32.
Name Position The position of the text in the workspace can be customized
here.
- 75-
ROI-S07012
5. Clicking the button (a) and keeping it depressed (with the mouse) displays all the
parameter settings for the respective NEs. Proceeding to (b) click General.
(a) (b)
The NODAL Group comprises a maximum of four (4) IDUs. Each IDUs functions differ
according to its position within the group: top, intermediate or bottom (end); as illustrated
below:
top
intermediate
IDU #2 in a three IDU configuration
IDUs #2 / #3 in a four IDU configuration
bottom
IDU #2 in a two IDU configuration
IDU #3 in a three IDU configuration
IDU #4 in a four IDU configuration
- 76-
ROI-S07012
- 77-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: PASOLINK NEO NODAL
(2-WAY), PASOLINK NEO NODAL (Terminal)
and PASOLINK NEO NODAL (Tributary Only).
Network Element Name The name of the NE in the network. Maximum
number of characters possible is 32.
Area Name The area where the NE is located (optional).
Maximum number of characters possible is 80.
Note Additional description, or remarks on the NE
(optional). Maximum number of characters
possible is 100.
CTRL CTRL Type Role of the CTRL in the network. Root NE,
Type Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs: None,
2, 3 or 4 branches.
Position/ Name Position The position of the text in the workspace can be
Direction customized here.
Antenna 2-WAY top
Direction Inter-mediate Not displayed
bottom
Terminal top
The antenna icon in the workspace can be
Inter-mediate customized to face either Right or Left.
bottom
Tributary top
Only Inter-mediate Not displayed
bottom
Line 2-WAY top The antenna icon in the workspace can be
Direction customized to face either Upper , Right or Left.
Inter-mediate Not displayed
bottom The antenna icon in the workspace can be
customized to face either Lower, Right or Left.
Terminal top
Inter-mediate Not displayed
bottom
Tributary top The antenna icon in the workspace can be
Only customized to face either Upper , Right or Left.
Inter-mediate Not displayed
bottom The antenna icon in the workspace can be
customized to face either Lower, Right or Left.
Port Information This provides the IP information of the available
port in the selected NE. The IP address that the
port uses and its subnet mask can be viewed in
this section.
- 78-
ROI-S07012
An example for the General settings in the right and window (above) is as follows:
Equipment Type: PASOLINK NEO NODAL (2-WAY)
CTRL Type: Root NE
Branch NE Type: Disable
- 79-
ROI-S07012
The Port display differs according to Equipment Type, Branch NE Type, IDU configuration.
NOTE:
- When Tributary Only is “E1 Tributary Only“, it is configured so that the modem can
only be connected to the power supply in/out (no ODU connections).
- When a Tributary Only IDU is in the intermediate position, there is no Port
combination available. Please refer to Appendix L 1.
- 80-
ROI-S07012
- 81-
ROI-S07012
*Terminal
- 82-
ROI-S07012
*Tributary Only
6. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.32.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
- 83-
ROI-S07012
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 84-
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 85-
ROI-S07012
2.9.16.5 Editing PNMS (EM1) Parameters (for Root NE only) of PASOLINK NEO NODAL
When Root NE is selected as the CTRL Type, the PNMS (EM1) category is displayed in the
Network overview.
To change the PNMS (EM1) Parameters:
1. Right click on the selected
NODAL Group to display
the context menu.
(Or double click on the
selected NODAL Group to
open the NODAL Group
Properties window.)
2. Click on Properties in the
context menu to open the
NODAL Group Properties
window.
3. The NODAL Group
Properties window will
appear.
4. Select the NE to be
modified.
5. The NE Properties window
will appear. Click on the PNMS (EM1) category to display the PNMS (EM1) parameters.
6. In this window, the IP Address and subnet mask and default gateway information of the
PNMS (EM1) port are defined. The definitions of these parameters are listed in Table 2.34.
Parameter Definition
LAN IP Address The IP address defines the usage by the IDU EM1 (NMS)
port. However, it is only used when the EM1 (NMS) port is
used for connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default IP Address Default Gateway of above mentioned EM1 (NMS) port.
Gateway Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 86-
ROI-S07012
- 87-
ROI-S07012
6. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 88-
ROI-S07012
2.9.16.8 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO NODAL
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Router
Root NE
(Bridge) No.01
No.02 No.03
#1
No.04 No.01
#2 No.05
No.01
No.06 No.07
#3
No.08 No.01
#4 No.09
Normal NE Normal NE
- 89-
ROI-S07012
- 90-
ROI-S07012
- 91-
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: PASOLINK NEO/a
Redundancy SW Group 1 The SW Group 1: Not Used, 1+0(1),1+0(2), 1+0(1 2),
1+1(Hot Standby), 1+1(Twin Path)
SW Group 2 The SW Group 1: Not Used, 1+0(1),1+0(2), 1+0(1 2),
1+1(Hot Standby), 1+1(Twin Path)
SW Group 3 The SW Group 1: Not Used, 1+0(1),1+0(2), 1+0(1 2),
1+1(Hot Standby), 1+1(Twin Path)
Network Element Name The name of the NE in the network. Maximum number
of characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 32.
Note Additional description, or remarks on the NE (optional).
Maximum number of characters possible is 100.
RCP Type RCP Type Role of the RCP in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs: None,
2, 3, 4, 5, 6, 7 or 8 branches.
Position/ Name Position The position of the text in the workspace can be
Direction customized here.
Line Direction The antenna icon in the workspace can be customized
to face either Upper, Right or Left.
Port Information This provides the IP information of the available port in
the selected NE. The IP address that the port uses and
its subnet mask can be viewed in this section.
- 92-
ROI-S07012
2. Click on Properties in
the context menu to
open the NEO/a
Properties window.
3. The NEO/a Properties
window will appear.
4. Click on the respective
Port category to display
the corresponding port
information.
An example for the General settings in the right and window (above) is as follows:
SW Group1: 1+0(1 2)
SW Group2: 1+0(1 2)
SW Group3: 1+0(1 2)
RCP Type : Root NE
Branch NE Type : Disable
- 93-
ROI-S07012
The Port display differs according to SW Group, RCP Type, Branch NE Type.
- 94-
ROI-S07012
- 95-
ROI-S07012
- 96-
ROI-S07012
- 97-
ROI-S07012
- 98-
ROI-S07012
- 99-
ROI-S07012
- 100-
ROI-S07012
- 101-
ROI-S07012
- 102-
ROI-S07012
- 103-
ROI-S07012
5. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.36.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that port’s
IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 104 -
ROI-S07012
- 105 -
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfg Toolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
2.9.17.4 Editing PNMS (EM1) Parameters (for Root NE only) of PASOLINK NEO/a
When Root NE is selected as the RCP Type, the PNMS (EM1) category is displayed in the
Network overview.
To change the PNMS (EM1)
Parameters:
1. Right click on the selected
NEO/a to display the
context menu.
(Or double click on the
selected NEO/a to open
the NEO/a Properties
window.)
2. Click on Properties in the
context menu to open the
NEO/a Properties window.
3. The NEO/a Properties
window will appear.
4. Click on the PNMS (EM1)
category to display the
PNMS (EM1) parameters.
5. In this window, the IP
Address and subnet mask
and default gateway information of the PNMS (EM1) port are defined. The definitions of
these parameters are listed in Table 2.38.
- 106 -
ROI-S07012
Parameter Definition
LAN IP Address The IP address defines the usage by the IDU EM1 (NMS) port.
However, it is only used when the EM1 (NMS) port is used for
connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default Gateway IP Address Default Gateway of above mentioned EM1 (NMS) port.
Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 107 -
ROI-S07012
5. The Time Synchronization mode can be set in this window. The time on the RCP module
can either be synchronized to a time-server with SNTP in the network or set to None (no
time synchronization). The IP address of the time-server as well as the Refresh Interval
(the time in seconds that elapses before the NE will try to synchronize its internal clock to
a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the RCP Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 108 -
ROI-S07012
2.9.17.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO/a
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfg Toolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
RCP Type, the IP Restriction category is displayed in the Network overview.
PNMS
Router
No.06 No.07
No.04 No.05
No.01
No.02 No.03
Root NE
(Bridge)
Normal NE Normal NE
- 109 -
ROI-S07012
- 110 -
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: PASOLINK NEO HP.
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 80.
Note Additional description, or remarks on the NE (optional).
Maximum number of characters possible is 100.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs: None,,
2, or 3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna Direction The antenna icon in the workspace can be customized to face
either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 111 -
ROI-S07012
Port category
Port category
- 112 -
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.40.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that port’s
IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 113 -
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 114 -
ROI-S07012
2.9.18.4 Editing PNMS (EM1) Parameters (for Root NE only) of PASOLINK NEO HP
When Root NE is selected as the CTRL Type, the PNMS (EM1) category is displayed in the
Network
overview.
To change the PNMS (EM1) Parameters:
1. Right click on the selected NE
to display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
2. Click on Properties in the
context menu to open the NE
Properties window.
3. The NE Properties window
will appear. Click on the
PNMS (EM1) category to
display the PNMS (EM1)
parameters.
4. In this window, the IP Address
and subnet mask and default
gateway information of the
PNMS (EM1) port are
defined. The definitions of
these parameters are listed
in Table 2.42.
Parameter Definition
LAN IP Address The IP address defines the usage by the IDU EM1 (NMS) port.
However, it is only used when the EM1 (NMS) port is used for
connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default Gateway IP Address Default Gateway of above mentioned EM1 (NMS) port.
Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 115 -
ROI-S07012
- 116 -
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CRTL module
can either be synchronized to a time-server with SNTP in the network or set to None (no
time synchronization). The IP address of the time-server as well as the Refresh Interval
(the time in seconds that elapses before the NE will try to synchronize its internal clock to
a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 117 -
ROI-S07012
2.9.18.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of PASOLINK NEO HP
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
PNMS
Router
Root NE Normal NE Normal NE Normal NE
(Bridge)
- 118 -
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: 5000S
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs: None, 2, or 3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 119 -
ROI-S07012
- 120 -
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.44.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 121 -
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 122 -
ROI-S07012
Parameter Definition
LAN IP Address The IP address defines the usage by the IDU EM1 (NMS)
port. However, it is only used when the EM1 (NMS) port is
used for connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default IP Address Default Gateway of above mentioned EM1 (NMS) port.
Gateway Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 123 -
ROI-S07012
- 124 -
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 125 -
ROI-S07012
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
PNMS
Router Root NE Normal NE Normal NE Normal NE
(Bridge)
- 126 -
ROI-S07012
Parameter Definition
System Equipment Type The type of equipment: 5000S (Terminal), 5000S
(2xTerminal) and 5000S (Repeater).
Network Element The name of the NE in the network. Maximum number of
Name characters possible is 32.
CTRL Type CTRL Type Role of the CTRL in the network. Root NE,
Root NE (Bridge), Branch NE or Normal NE.
Branch NE Type The number of Branch NEs for 5000S (2xTerminal) and
5000S (Repeater): None, 2, 3 or 4 branches.
The number of Branch NEs for 5000S (Terminal): None, 2 or
3 branches.
Position/ Name Position The position of the text in the workspace can be customized
Direction here.
Antenna The antenna icon in the workspace can be customized to face
Direction either Right or Left.
Port Information This provides the IP information of the available port in the
selected NE. The IP address that the port uses and its subnet
mask can be viewed in this section.
- 127 -
ROI-S07012
<5000S (2xTerminal)>
a) EAST/WEST/EM2 Port b) EAST/WEST/EM2/EM1 Port
---- Root NE --- Root NE (Bridge), Normal NE, Branch NE (No
Branch)
Port category
- 128 -
ROI-S07012
d) EAST Port / WEST Port / EM2/EM1 Port e) EAST Port / WEST Port / EM2 Port / EM1 Port
--- Branch NE (3Branches) --- Branch NE (4Branches)
<5000S (Repeater)>
a) DIR-A/DIR-B/EM2 Port b) DIR-A/DIR-B/EM2/EM1 Port
---- Root NE --- Root NE (Bridge), Normal NE, Branch NE (No Branch)
- 129 -
ROI-S07012
Port category
d) DIR-A Port / DIR-B Port / EM2/EM1 Port e) DIR-A Port / DIR-B Port / EM2 Port / EM1 Port
--- Branch NE (3Branches) --- Branch NE (4Branches)
- 130 -
ROI-S07012
<5000S (Terminal)>
a) Radio/EM2 Port b) Radio/EM2/EM1 Port
---- Root NE -- Root NE (Bridge), Normal NE, Branch NE
(No branch)
c) EM2/EM1 Port / Radio Port d) Radio Port / EM2 Port / EM1 Port
--- Branch NE (2Brances) --- Branch NE (3Branches)
- 131 -
ROI-S07012
4. In this window, the IP Address for the respective port is defined. These parameters are
defined in Table 2.48.
NOTE: The IP addresses, Subnet Masks can only be manually set if selected in the “Assign
IP Address manually” or “Assign Subnet Mask manually” check box.
Parameter Definition
Assign IP Address manually When “Assign IP Address manually” check box is selected,
user can modify IP Address.
Assign Subnet Mask manually When “Assign Subnet Mask manually” check box is
selected, user can modify Subnet Mask.
Network Primary When the “Primary” check box of a port is selected, that
port’s IP address becomes detectable by the PNMS.
IP Address IP address of the respective port.
Subnet Mask Subnet mask of the respective port.
Subnet Name Defines the name of the respective port sub-network.
- 132 -
ROI-S07012
Parameter Definition
Common Data Link Type of data link protocol used by Async. This is always set at
HDLC when connected in multi-drop with another NE. The
data link will be set to PPP when connected to a Pasolink
V3/Pasolink V4/Pasolink-S/MIU CPMC.
IP Address IP address of Async port.
Subnet Mask Subnet mask of Async port.
Speed Speed of Async port.
HDLC Mode Specifies if the Async port is used in HDLC. The Async port
can either be Master, Slave or blank.
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s Async port, if it is the last port
in the HDLC line. (Recommended)
Terminate If “Terminal Auto Assign” is set to Manual, the Async port
termination can be set to On or Off.
- 133 -
ROI-S07012
2.9.20.4 Editing PNMS (EM1) Parameters (for Root NE only) of 5000S (1NE)
When Root NE is selected as the CTRL Type, the PNMS (EM1) category is displayed in the
Network overview.
To change the PNMS (EM1) Parameters:
1. Right click on the selected NE
to display the context menu.
(Or double click on the
selected NE to open the NE
Properties window.)
2. Click on Properties in the
context menu to open the NE
Properties window.
3. The NE Properties window
will appear. Click on the
PNMS (EM1) category to
display the PNMS (EM1)
parameters.
4. In this window, the IP Address
and subnet mask and default
gateway information of the
PNMS (EM1) port are defined.
The definitions of these
parameters are listed in Table
2.50.
Parameter Definition
NMS IP Address The IP address defines the usage by the IDU EM1 (NMS)
port. However, it is only used when the EM1 (NMS) port is
used for connecting to the PNMS
IP address. This is only set if the selected NE is a Root NE.
Subnet Mask Subnet mask of above mentioned EM1 (NMS) port.
Default Default Gateway of above mentioned EM1 (NMS) port.
Gateway Normally the IP address of the PNMS PC / Workstation or the
router associated with the PNMS.
- 134 -
ROI-S07012
- 135 -
ROI-S07012
4. The Time Synchronization mode can be set in this window. The time on the CTRL
module can either be synchronized to a time-server with SNTP in the network or set to
None (no time synchronization). The IP address of the time-server as well as the Refresh
Interval (the time in seconds that elapses before the NE will try to synchronize its internal
clock to a specified time-server) can be set in this window.
NOTE: Please reenter the correct SNTP IP Address, when the CTRL Type in the General
category window is changed from Root NE to Root NE (Bridge) or vice- versa.
- 136 -
ROI-S07012
2.9.20.7 Editing IP Restriction Parameters (for Root NE [Bridge] only) of 5000S (1NE)
In network configurations where the Subnet is not supposed to be disconnected at the Root NE,
IP addresses can be preset for devices connected ahead of the Root NE in the IP Restriction
Category window (for instance: IP addresses for the PNMS computer or the router). When
configuring (Create Configuration) with NetCfgToolj, IP addresses (apart from any preregistered
ones) are automatically assigned to other devices. When Root NE (Bridge) is selected as the
CTRL Type, the IP Restriction category is displayed in the Network overview.
PNMS
Root NE Normal NE Normal NE Normal NE
(Bridge)
Subnet
- 137 -
ROI-S07012
A Line Concentrator is a Stand-alone MIU that is used as a CPMC to poll other NE’s in its
sub-network.
To modify the properties of MIU (Line Concentrator):
- 138 -
ROI-S07012
Parameter Definition
System Equipment In Line Concentrator this field will display “Line Concentrator”
and will not be selectable (appears gray).
Redundancy Not Applicable.
Total PMC The total number of PMC’s needed to monitor the selected
equipment.
NOTE: In case of Line concentrator, ONLY 1 PMC is possible.
DO NOT set the Total PMC to a value greater than 1.
Type Not Applicable.
Repeater Type Not Applicable.
Bit Rate ID Not Applicable.
FASYNC Alarm Not Applicable.
Active
Symbol Name The name that will be associated with the selected Line
concentrator symbol. Maximum number of characters
possible is 29.
NOTE: This is the primary name NE in the workspace. This
name will NOT be associated to the configuration file for this
NE. To set the name for the configuration file see section
2.9.9.1) Editing General Parameters of MIU (Line
Concentrator), Table 2.16)
Name Position The position where the name of the selected Line
concentrator will be displayed.
Line Direction Defines on which side the NMS line will be added to the Line
concentrator.
MIU CPMC Normal This button contains the NE properties of the Line
concentrator. This contains the network, HDLC, port and
other parameters connected to the NMS setting of the MIU.
(See Appendix A: MIU Setting)
- 139 -
ROI-S07012
Parameter Definition
System NetworkElement The name that will be associated with the target NE. This
Name name will be applied in the configuration files. Maximum
number of characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 32.
Note Additional description of the NE (optional). Maximum number
of characters possible is 100.
PMC Usage Not Available
Equipment Type Displayed as Line Concentrator (not selectable).
Performance Not Available.
Monitor Input
A/D Convert Type The number of Analog-to-Digital conversions used in the MIU.
The MIU is capable of processing a maximum of two (2) A/D
conversions.
PMC Type Set as CPMC for line concentrators – cannot be modified.
- 140 -
ROI-S07012
Parameter Definition
HDLC Timer Master Timeout The time in seconds after which the PMC will assume
that it has lost the communication link with the master
PMC.
Master Interval The interval in seconds at which the PMC will check for
the polling signal from the master PMC
Slave Timeout The time in seconds after which the master PMC will
assume that the link with its slave PMC is lost.
Role Change Auto Role Change If enabled, the PMC will automatically change its
function from slave to master PMC, once it has lost its
link with the master PMC in the upper network. It will
also automatically change back to slave once the link
with the master is restored. This is normally set to
"Enable".
Role Change Timeout The elapsed time in seconds that the slave PM card
waits for the polling message from the CPMC before it
changes over to assume the role of the CPMC.
HDLC Relay High BER DPU Inhibit If High BER DPU Inhibit is set to Enable, Hi BER alarm
is inhibited. This means that it will not be activated even
if the DPU port receives deficient data.
- 141 -
ROI-S07012
Parameters Definition
DPU Port* Action Mode Defines the role of the DPU Port of MIU.
Disabled for Line Concentrator.
Baud Rate Not applicable.
Mode Not applicable.
NMS Port Action Mode Defines the role of the NMS Port of MIU.
Set to Master for Line concentrators.
Baud Rate Defines the speed of the NMS Port in bits-per-second
(bps).
Mode Auto Assign If Mode Auto Assign is set to Manual, the mode on the
NMS port can be set to RS485_TX or RS485_RX.
Mode Defines the wiring (interface) protocol used
Terminal Auto Assign Automatically allow the NetCfgToolj to terminate the
HDLC connection of the selected NE’s NMS port, if it is
the last port in the HDLC line. (Recommended)
Terminate If Terminal Auto Assign is set to Manual, the termination
on the NMS port can be set to Enable or Disable.
Terminates the RS485 protocol line when enabled.
- 142 -
ROI-S07012
Parameter Definition
Set Time Auto Set Time If enabled, the PMC automatically synchronizes its time to
that of the PNMS or the CPMC.
Set Time Interval The time interval before the PMC periodically
synchronizes its time to that of the PNMS or CPMC.
Flash ROM Auto Write Back If enabled, the PMC automatically writes the Log data and
PM data to the Flash ROM.
Write Back Interval The time interval before the PMC writes the Log data and
PM data to the Flash ROM.
- 143 -
ROI-S07012
- 144 -
ROI-S07012
Parameter Definition
PNMS Connection Defines the type of connection that the PMC in the Line
concentrator has the PNMS. There are three (3) possible
PNMS connections allowed by the PMC namely:
RS-232C: PNMS connects to the PMC using
RS-232C/19.2kbps Asynchronous interface.
RS-422: PNMS connects to the PMC using
RS422/19.2kbps/V.11 Asynchronous Interface
LAN: PMC connects directly to an Ethernet network using
10BaseT/10Mbps interface.
LAN* IP Address Defines the IP address that will be assigned to the
LAN-PNMS port of the PMC.
Subnet Mask Defines the subnet mask used by the LAN port of the PMC.
Default Defines the IP address of the machine where the traps from
Gateway the PMC will be forwarded.
In cases where the PNMS PC/WS is in the same network
(LAN) as the PMC, this will normally be the IP address of the
PNMS PC/WS.
In case of WAN or networks wherein the PNMS is located in
another network, this will be the IP address of the nearest
router.
RS232C/RS422 Connection Specifies whether the RS232C/RS422 connection is Direct or
Type through Router.
Direct - connection means the PNMS PC connects to the
CPMC using its local COM ports.
Router – means that the CPMC is connected to the PNMS
through a router. In this case the IP address must be in the
same subnet as the router’s serial port.
IP Address Defines the IP address that will be assigned to the PNMS port
of the PMC.
Subnet Mask Defines the subnet mask used by the PNMS port of the PMC.
*Option –only available if the PMC used in the Line Concentrator supports LAN connection
- 145 -
ROI-S07012
This is a type of MIU that is equipped with microwave radio and can be used as CPMC, SCPMC
or RPMC. To modify MIU (Hop) properties:
1. Right click on the selected MIU (Hop) to display the context menu.
(Or double click on the selected MIU to open the Properties window of the selected
MIU.)
2. Click on Properties in the context menu to open the Properties window of the selected
MIU (Hop).
3. The Properties window of the MIU contains the parameters shown and defined in Table
2.57.
- 146 -
ROI-S07012
Parameter Definition
System Equipment Specifies the type of equipment monitored by the MIU. They
are 2000S or 2300S or 2500S or 2600S or 3000S or 3500S or
Other equipment.
Redundancy The redundancy of the selected equipment. (1+0, 1+ 1, or
N+1 system.)
Total PMC The total number of PMC’s needed to monitor the selected
equipment.
Type When the selected equipment is 2000S or 2500S or 2600S,
the termination type is specified in this parameter. The
equipment type specified above can either be Repeater or
Terminal type.
Repeater Type The repeater type specifies the mode of repeating the signal
at the 2600S radio. The 2600S can function as either a
“Drop-In” or “Through” repeater. This is only available for
2600S radio with the repeater function enabled. (See also
Type.)
Bit Rate ID This parameter specifies the bit rate of the 2500S radio
(32MB, 8x2MB or 4x2MB). When Other Equipment is
selected the bit rate selection is (34MB, 17MB, or 8MB). This
parameter is not available for other equipment types. This
data is used for the Block Error Counter (BEC) of the
Performance Monitor function.
FASYNC Alarm Active Specifies when the FASYNC alarm is active for the selected
equipment. (Low Active or High Active) This data is used in
UAS measurement of the Performance Monitor.
Symbol Name The primary name that will be associated with the target
MIU’s symbol in the workspace. This name will be the one
displayed in the NetCfgToolj workspace and will NOT be
associated with the configuration files. Maximum possible
number of characters is 29.
To set the NE name for the configuration files, please go to
section 2.9.10.1 1) Editing General Parameters of MIU (Hop),
Table 2.22) and set the PMC’s individually –if more than one
PMC is installed in the target MIU.
Name Position The position where the name of the target MIU will be
displayed.
Line Direction Defines which side the NMS line will be added to the MIU.
MIU PMC Button This button contains the NE properties of the MIU. This
[CMPC/SCPCM/RPMC contains the network, HDLC, port and other parameters
Normal/Additional/etc] connected to the NMS setting of the MIU. It also describes the
PMC type (CPMC, SCPMC, or RPMC) and the PMC Usage
(Normal, Additional PC, Regular CH, or Protection CH). (See
Appendix A: MIU Setting)
- 147 -
ROI-S07012
- 148 -
ROI-S07012
Parameter Definition
System NetworkElement The name that will be assigned to the target NE. This name
Name will be applied in the configuration files. Maximum number of
characters possible is 32.
Area Name The area where the NE is located (optional). Maximum
number of characters possible is 32.
Note Additional description of the NE (optional). Maximum number
of characters possible is 100.
PMC Usage If the selected MIU contains more than one PMC, the
following PMC usage will apply:
1. ) For 1+0/1+1/Line Concentrator/Other Equipment system:
a.) 1st PMC is used as Normal. b.) and the other PMC's are
used as Additional PMCs.
2.) For N+1 system: a) 1st PMC is used as Protection CH. b.)
and the other PMC's are used as Regular CH or Additional
PMC.
Equipment Type The type of equipment monitored by the target MIU.
Performance The number of MIU channels used for performance
Monitor Input monitoring functions. The MIU can accommodate up to 2 CH
for performance monitoring purposes.
A/D Convert Type The number of Analog-to-Digital conversions used in the MIU.
The MIU is capable of processing a maximum of two (2) A/D
conversions.
PMC Type The role of the PMC in the target MIU NE in the HDLC chain.
- 149 -
ROI-S07012
Parameters Definition
HDLC Timer Master The time in seconds wherein the PMC will assume that it has
Timeout lost communication link with the master PMC.
Master Interval The time in seconds where in the PMC will check for the
polling signal from the master PMC.
Slave Timeout The time in seconds wherein the master PMC will assume
that the link with its slave PMC is lost.
Role Change Auto Role If enabled, the PMC will automatically change its function from
Change slave to master PMC, once it has lost its link with the master
PMC in the upper network. It will also automatically change
back to slave once the link with the master is restored. This
is normally set to "Enable".
Role Change The elapsed time in seconds that the slave PM card waits for
Timeout the polling message from the CPMC before it adopts the
function of the CPMC.
HDLC Relay High BER DPU If High BER DPU Inhibit is set to Enable, Hi BER alarm is
Inhibit inhibited. This means that it will not be activated even if the
DPU port receives degraded data.
- 150 -
ROI-S07012
Parameters Definition
DPU Port Action Mode Defines the role of the DPU Port of MIU.
Baud Rate Defines the speed of the DPU Port in bits-per-second (bps).
Mode Defines the protocol used in the DPU port. RS-422/RS232
and G.703 can be used in the MIU’s DPU port.
NMS Port Action Mode Defines the role of the NMS Port of MIU.
Baud Rate Defines the speed of the NMS Port in bits-per-second (bps).
Mode Auto If Mode Auto Assign is set to Manual, the mode on the NMS
Assign port can be set to RS485_TX or RS485_RX.
Mode Defines the wiring (interface) protocol used
Terminal Auto Automatically allow the NetCfgToolj to terminate the HDLC
Assign connection of the selected NE’s NMS port, if it is the last port
in the HDLC line. (Recommended)
Terminate If Terminal Auto Assign is set to Manual, the termination on
the NMS port can be set to Enable or Disable.
Terminates the RS485 protocol line when enabled
- 151 -
ROI-S07012
Parameter Definition
Set Time Auto Set Time If enabled, the PMC automatically sets it time to match that of
the PNMS or the CPMC.
Set Time Interval The time interval before the PMC periodically synchronizes its
time to the PNMS or CMPMC.
Flash ROM Auto Write Back If enabled, the PMC automatically writes the Log data and PM
data to the Flash ROM.
Write Back Interval The time interval before the PMC writes the Log data and PM
data to the Flash ROM.
- 152 -
ROI-S07012
- 153 -
ROI-S07012
Parameter Definition
PNMS Connection Defines the type of connection that the PMC in the Line
concentrator has with the PNMS. There are three (3) possible
PNMS connections allowed by the PMC namely:
RS-232C: PNMS connects to the PMC using
RS-232C/19.2kbps Asynchronous interface.
RS-422: PNMS connects to the PMC using
RS422/19.2kbps/V.11 Asynchronous Interface
LAN: PMC connects directly to an Ethernet network using
10BaseT/10Mbps interface.
LAN* IP Address Defines the IP address that will be assigned to the
LAN-PNMS port of the PMC.
Subnet Mask Defines the subnet mask used by the LAN port of the PMC.
Default Defines the IP address of the machine where the traps from
Gateway the PMC will be forwarded.
In cases where the PNMS PC/WS is in the same network
(LAN) as the PMC, this will be normally the IP address of the
PNMS PC/WS.
In case of WAN or networks wherein the PNMS is located in
another network, this will be the IP address of the nearest
router.
RS232C/RS422 Connection Specifies whether the RS232C/RS422 connection is Direct or
Type through Router.
Direct – connection means the PNMS PC connects to the
CPMC using its local COM ports.
Router – means that the CPMC is connected to the PNMS
through a router. In this case the IP address must be in the
same subnet as the router’s serial port.
IP Address Defines the IP address that will be assigned to the PNMS port
of the PMC.
Subnet Mask Defines the subnet mask used by the PNMS port of the PMC.
*Option –only available if the PMC used in the MIU supports LAN connection.
- 154 -
ROI-S07012
3. The Line Properties window will appear. The Connect Mode (e.g. RS-485 or RS-232C)
of any two NEs connected via back-to-back connection can be changed. Connect Port
specifies the Pasolink Mx/Pasolink+ port where line (back-to-back) is to be connected –
this is only available for Pasolink Mx/Pasolink+ NE’s. Pasolink Mx/Pasolink+ can have
back-to-back connections on NE1, NE2 or LAN ports. PASOLINK NEO/PASOLINK NEO
CPV/PASOLINK NEO NODAL/PASOLINK NEO/a /PASOLINK NEO HP/5000S can have
back-to-back connections on EM1 (NMS), EM2 (NE) or ASYNC ports. Any two NEs
connected back-to-back can be assigned a Line Name.
- 155 -
ROI-S07012
4. After user modifies Line Name in the Line Properties window, Line Name will be
displayed on the Network window as follows.
- 156 -
ROI-S07012
3. The create configuration window wizard will be displayed. Click on [Next] button to
continue.
4. Check the “Automatically set PMC type” box if necessary on the ensuing window. By
ticking this box, NetCfgToolj will automatically set PMC type and allocate NE's according
to the maximum number of NE's that can be contained in a sub-network. Click on [Next]
button to continue.
- 157 -
ROI-S07012
5. A message box, stating the status of the configuration will appear. If no errors are
encountered during the network configuration, this message will just prompt the user that
process was “Completed successfully". Click on [Next] button to continue.
7. Glide the pointer over the NE’s displayed in the workspace to verify if all the NE’s have
been assigned with appropriate IP address and names.
- 158 -
ROI-S07012
When “Create Configuration (All Networks)" is executed, the progress bar will be displayed.
Clicking the Cancel button of the progress bar window immediately terminates the network
configuration process, whereby any partially completed Network Configurations will be retained
in the state they were in at the time the button was clicked.
Moreover, if during the "Create Configuration (All Networks)" procedure, the in-process
configuring of any of the networks were disrupted, an error message would be issued for the
affected network; whereby, configuring for any remaining networks would be aborted.
- 159 -
ROI-S07012
To display this window, click on File Æ Changed NEs List in the main menu.
[Close] button can be used to close the window.
[Save] button can be used to save the listing to a csv file.
Item Definition
Selected Network Selected Network (Default):
The Changed NEs List window displays only the NE information for
the Network that has been selected.
All Networks:
The Changed NEs List window displays the entire NE information
for all NEs in all Networks.
- 160 -
ROI-S07012
The Network Element List contains the following information about the selected (or all) networks:
Item Definition
Highlighting Highlighted NEs are denoted by checkmark
Network Name Network Name
Subnet Name Subnet Name
Network Element Name Network Element Name
Equipment Type The type of equipment:
Pasolink V3, Pasolink V4, Pasolink-S
MIU (LineConcentrator), MIU
Pasolink Mx, Pasolink+ STM-1, Pasolink+ STM-0, Pasolink+ PDH
PASOLINK NEO, PASOLINK NEO (2-WAY), PASOLINK NEO (Terminal)
PASOLINK NEO CPV, PASOLINK NEO CPV (Terminal)
PASOLINK NEO NODAL (2-WAY), PASOLINK NEO NODAL (Terminal)
PASOLINK NEO NODAL (Tributary Only), PASOLINK NEO/a
PASOLINK NEO HP
5000S, 5000S (Terminal), 5000S (2xTerminal), 5000S (Repeater)
Pasolink Mx (Bridge NE), Pasolink+ SMT-1 (Bridge NE)
Pasolink+ PDH (Bridge NE)
PMC Type CPMC/SCPMC/RPMC
(for Pasolink V3/Pasolink V4/Pasolink-S/MIU only)
Root NE/Branch NE/Normal NE
(for Pasolink Mx/Pasolink+ only)
Root NE/Root NE (Bridge)/Branch NE/Normal NE
(for PASOLINK NEO/PASOLINK NEO CPV/
PASOLINK NEO NODAL/ PASOLINK NEO/a /
PASOLINK NEO HP 5000S )
Primary An asterisk (*) denotes that that the IP Address is the Primary IP Address
IP Address IP Address of the respective port
Network Address Network Address of the respective port
Subnet Mask Subnet mask of the respective port
- 161 -
ROI-S07012
Item Definition
Selected Network Selected Network (Default):
The Network Element List window displays only the NE information for
the Network that has been selected.
All Networks:
The Network Element List window displays the entire NE information
for all NEs in all Networks.
Select Element Type The Network Element List window displays only information for the selected
Equipment Type.
The match condition is partial agreement with the character string entered
in the input field.
* Combo box (The following items can be selected):
Network Name/Subnet Name/Network Element Name/
IP Address/Network Address
*Text input field
A maximum of 32 characters may be inputted.
*Up/Down Radio-button
Up: searches bottom to top
Down: searches top to bottom
[Close] button can be used to exit (i.e. close) the Network Element List window.
[Save] button can be used to store (i.e. save) the listing in a csv file.
[Print] button can be used to print a hard copy of the list using a printer.
Note: Highlighted item column names or Primary item column names to be saved or printed out
are shortened; because, during [Save] and [Print] processing, the Mark designations (data
portion) for the highlighted item (#) and Primary Item (*) are outputted together.
- 162 -
ROI-S07012
As illustrated here; when a line is selected and right-clicked, the Highlighting ON/Highlighting
OFF menu is displayed. When the Highlighting function is executed from the Highlighting
ON/Highlighting OFF menu, this will be reflected in real time in the respective NE symbol for
the Network Element Name displayed in the Highlighting column and the corresponding
Network screen in the Network Element List window.
- 163 -
ROI-S07012
2. Specify the directory of the folder where the PM Card network configuration file is to be
exported. The exported file should be config (*.cfg) format. The file will be stored in
/../PM-Card/Network-x folder.
- 164 -
ROI-S07012
8. Verify that the file has been saved in the designated folder.
- 165 -
ROI-S07012
2. Specify the Folder and File Name where the current workspace is to be saved.
3. Click on [Save] button.
4. Verify that the workspace was saved in the selected folder.
- 166 -
ROI-S07012
1. Click on File Æ Print Area Æ Setting from the main menu of the main window.
2. The default printing area (extending over the entire window) is outlined by a light-blue
dotted line as shown below.
- 167 -
ROI-S07012
3. To define a different printing area (Print Area), depress the left button of the mouse and
draw a box around the desired area as shown below.
4. Click on File Æ Print from the main menu of the main window to start printing.
- 168 -
ROI-S07012
2. Specify the Folder and File Name where the Network Address is to be saved.
- 169 -
ROI-S07012
2. Select the *.csv file of the Network Address from the list
- 170 -
ROI-S07012
5. Verify that the correct Network Address File is added to the Network Properties window.
NOTE:
*Network Address file format is as shown below.
Network Id, Network Name, Network Address, Subnet Mask
- 171 -
ROI-S07012
1. Click on Help Æ About NetCfgToolj from the main menu of the main window.
- 172 -
ROI-S07012
- 173 -
ROI-S07012
- 174 -
ROI-S07012
The name of the PMC button is comprised of two distinct parts: (1) PMC type, (2) PMC Usage. The
PMC type can either be RPMC, CPMC or SCPMC depending on the role of the PMC in the HLDC
polling.
The PMC Usage depends on the order of the PMC in the MIU and the redundancy. The table
below illustrates the PMC usage convention used in the MIU.
- 175 -
ROI-S07012
Appendix B: Subnets
Table B1 Available IP Address and Subnet for Managed Network
- 176 -
ROI-S07012
- 177 -
ROI-S07012
- 178 -
ROI-S07012
- 179 -
ROI-S07012
NMS DPU
Multi-Drop Connection
2. The configuration below is prohibited. Create Configuration will result in error, since MIU
(No.007) may not be set to DPU Port on the Slave side of the Multi-Drop connection.
NMS
DPU
- 180 -
ROI-S07012
HDLC
19.2 kbps
PPP
19.2 kbps
- 181 -
ROI-S07012
2. To change the connection of No.005 and No.007 from ASYNC to SYNC, please use the
Line Properties dialog box. Please change the port for No.005 from NE2 to NE1.
3. After the line properties are modified, the configuration will be shown as below and
configuring (Create Configuration) will then be possible.
HDLC
64 kbps
PPP
19.2 kbps
- 182 -
ROI-S07012
NMS
NMS
2. Confirm that “Connect Port” of each MIU is set to “NMS” by opening “Line Properties”
between No.003 and No.004 in Pattern 1 or between No.003 and No.005 in Pattern 2.
- 183 -
ROI-S07012
3. In the above example, please confirm that both MIU’s do not have the same “NMS Port”
setting, by opening the “Port” category in “NE Properties”. If they are set to the same mode
please reset the “NMS Port” mode for the CPM by selecting the “Manual” mode in the
“Mode Auto Assign” setting from the “Port” category in “NE Properties”, so that the “NMS
Ports” of both MIUs can communicate by connecting them with a straight cable.
Note: When a 2 system (NE) type MIU is used in the above configuration, please be sure that
the “Connect Port” setting for both NEs is “NMS” and that the “Mode” setting of one “NMS
Port” is “RS485_TX” and the other is “RS485_RX” or vice versa. If the same mode is set
to both NMS Ports, the NMS Ports cannot communicate, because the NMS Ports for
both NEs are internally connected by straight cable.
- 184 -
ROI-S07012
The dotted square in the following figures shows examples of usage for 2 system (NE) type MIU.
NMS NMS
NMS
NMS
NMS NMS
- 185 -
ROI-S07012
The following diagram shows such a case: No.005 (Pasolink NEO) is connected to No.003
(Pasolink Mx [Bridge NE]), and No.007 (Pasolink Mx [Bridge NE]). Since No. 003 is
connected to No. 005 via the EM1 connecting port and No. 007 is connected via the EM2, if
a hub were not used, a LAN connection with cross-cables would be necessary. Since, this is
not technically possible there is no other alternative to using a hub.
SYNC connection
Mx Mx Mx Mx
No.003
connecting port:
NEO NEO EM1
LAN connection
(cross cable)
Mx Mx
No.007
connecting port:
EM2
2. To change the port with which No.005 is connected to No.007, use the Line Properties
dialog box. Please change the port of No.005 from (“EM2") to ("EM1").
- 186 -
ROI-S07012
3. After changing the line setting, configuring (Create Configuration) will be possible (however,
the display on the screen does not change) because interconnection between NEs will now
be via hub.
SYNC connection
Mx Mx Mx Mx
H NEO NEO
U
B
No.003
Mx Mx connecting port:
EM1
LAN connection
No.007
connecting port:
EM1
- 187 -
ROI-S07012
When a hub is used as in the following example linking No.002, (Pasolink NEO), No.004,
(Pasolink NEO) and No.005 (Pasolink NEO), it is not possible to extend two or more
connected lines from No.002 (Pasolink NEO).
Instead, it is necessary to change the connection mode shown on the screen (case 1) or to
change to a hub-less connection (case 2).
LAN connection
No.002 connecting
port: EM1
1. To remove the connecting line between No.002 andNo.004, select Line Delete
No.005
connecting port:
EM1
- 188 -
ROI-S07012
3. After changing the line setting, interconnection between NEs will not be changed; but,
the screen will change (as shown below) and configuring (Create Configuration)
will be possible.
LAN connection
1. Use the Line Properties dialog box to change the port via which No.002 is connected
with No.004. Please change the port of No.002 from (“EM1") to ("EM2").
2. After changing the line setting, configuring (Create Configuration) will be possible
(however, the display on the screen does not change) because interconnection
between NEs will not be via hub.
No.002
connecting port:
EM1
LAN connection
NEO NEO NEO NEO
- 189 -
ROI-S07012
2. Use the Line Properties dialog box to change the port via which No.001 is connected with
No.003. Please change the port of No.001 from (“EM1") to ("EM2").
- 190 -
ROI-S07012
(1) From the menu, select and execute File-Open to open the network configuration file
(*.nct) already existing in PNMSj.
(2) Change the Paso+/Mx to Bridge NE mode. (pls. refer to section 2.9.7)
Note: Subnet mask and IP address are automatically reset.
(3) From the menu, select and execute Tools-Create Configuration to update the network
configuration file (*.nct).
(4) From the menu, select and execute File-Save or File-Save As to save the updated
network configuration file (*.nct).
(5) From the menu, select and execute File-Export-Configuration Files for PM Card to
update the PMC network configuration files (*.cfg).
- 191 -
ROI-S07012
(1) Using the PNMTj Download feature, download the Bridge NE mode PMC Program file to
each respective NE.
Note: Use only program files that correspond to
one of the following versions (or newer).
(a) STM-1 : version 1.6.2
(b) PDH : version 1.2.2
(c) Mx : version 1.2.4
(2) Using the PNMTj Reset feature reset the CPU for each of the respective NE from step
(1).
Note: When resetting, be sure that the ROM (Program) switching checkbox is checked.
(3) Using the PNMTj Version display feature, verify that the Pasolink versions of the
downloaded NE are correct.
(4) Using the PNMTj Download feature, download the PMC network configuration file (*.cfg)
that was updated using NetConfigToolj.
- 192 -
ROI-S07012
(5) Rewire the actual connections for each respective actual NE wherever Async cable is
replaced by LAN cable in Tools-Create Configuration of NetConfigToolj.
In the following examples, when changing NEs to Bridge NE mode, the back-to-back
connecting cables between the NEs in the red circle (No.003, No.005, and No.007) are
automatically changed from Async to LAN cable and the connecting port is changed
from NE1/NE2 to LAN.
Proceed to the respective NE locations and change the connecting line from Async to
LAN cable and the connecting port to LAN.
Note: Since the LAN port only has one outlet, a repeater hub should be used for
Back-to-Back connection to two or more NEs.
Since, the Sync cable can be used as is, there is no need to change to LAN cable.
Before After
Sync Sync
Mx Mx Mx Mx Mx Mx Mx Mx
Async H
U
Mx Mx Mx Mx
B
Async
Mx Mx Mx Mx
(6) Using the PNMTj Search for Network Element feature, verify that all NEs are properly
displayed.
Note: Using this feature requires a license.
- 193 -
ROI-S07012
(1) From the menu, select and execute NetworkConfiguration-Update to import the
network configuration file (*.nct) that was updated using NetConfigToolj.
- 194 -
ROI-S07012
Appendix K: How to change Pasolink Mx (Bridge NE) / Pasolink+ STM-1 (Bridge NE)
/ Pasolink+ PDH (Bridge NE) to NEO
1. With NetConfigToolj execute the following procedure:
(1) From the menu, select and execute File-Open to open the network configuration file
(*.nct) already existing in PNMSj.
(2) Change from Paso+/Mx Bridge NE mode to PASOLINK NEO (HOP) mode.
(pls. refer to section 2.9.8)
Note: As regards subnet mask and IP address, the preset values are given priority.
(3) From the menu, select and execute Tools-Create Configuration...and update network
configuration file (*.nct).
(4) From the menu, select and execute File-Save or File-Save As to save the updated
network configuration file (*.nct).
(5) From the menu, select and execute File-Export-Configuration Files for PM Card to
update the PMC network configuration files (*.cfg).
- 195 -
ROI-S07012
Before After
Sync
Mx Mx Mx Mx Mx Mx H NEO NEO
H U
U B Mx Mx
Mx Mx
B
Mx Mx Mx Mx
(3) Using the PNMTj Download feature, download the Bridge NE mode NEO (PMC)
Program file to each respective NE.
Note: Use only program files that correspond to the following version (or newer).
(a) NEO: version 2.0.9
- 196 -
ROI-S07012
(4) Using the PNMTj Reset feature, reset the CPU for each of the respective NE from step
(3).
Note: When resetting, be sure that the ROM (Program) switching checkbox is checked.
(5) Using the PNMTj Version display feature, verify that the Pasolink versions of the
downloaded NE are correct.
(6) Using the PNMTj Download feature, download the PMC network configuration file (*.cfg)
that was updated using NetConfigToolj.
Note: Every NE whose file name is displayed in the Changed Configuration file (s)
column of the NetConfigToolj Changed NEs List is subject to said downloading of
Network configuration file (*.cfg).
- 197 -
ROI-S07012
(7) Using the PNMTj Search for Network Element feature, verify that all NEs are properly
displayed.
Note: Using this feature requires a license.
(1) From the menu, select and execute NetworkConfiguration-Update to import the
network configuration file (*.nct) that was updated using NetConfigToolj.
- 198 -
ROI-S07012
available
available
- 199 -
ROI-S07012
- The PNMS Line can only be connected to IDU#1for the Create Configuration tool to
function properly (in-feed only possible via top IDU).
- 200 -
ROI-S07012
Because the PNMS Line would be connected to the NODAL EM2, the Create Configuration
tool will not function properly
- 201 -
ROI-S07012