Beruflich Dokumente
Kultur Dokumente
14.07.2009
Notes:
Copyright 2009 QuantityWare GmbH. All rights reserved.
SAP, R/3, mySAP, mySAP.com, xApps, xApp, SAP NetWeaver, and other SAP products and services
mentioned herein as well as their respective logos are trademarks or registered trademarks of SAP AG in
Germany and in several other countries all over the world. All other product and service names mentioned
are the trademarks of their respective companies.
Microsoft, Windows, SQL-Server, Powerpoint and Outlook are registered trademarks of Microsoft
Corporation.
These materials and the information therein are subject to change without notice. These materials are
provided by the company QuantityWare GmbH for informational purposes only. There is no implied
representation or warranty of any kind, and QuantityWare GmbH shall not be liable for errors or omissions
with respect to the materials provided. The only warranties for the products and services of QuantityWare
GmbH are those set forth in the express warranty statements accompanying such products and services, if
any. No statement within this document should be construed as constituting an additional warranty.
2/18
Contents
BCP 10A ........................................................................................................................................ 1
Notes: ............................................................................................................................... 2
Contents ........................................................................................................................... 3
Introduction ....................................................................................................................... 4
1. Installation..................................................................................................................... 5
3/18
Introduction
This is a short description of a major standard within the BCP 10A suite - the Standard API
Chapter 11.1 - Physical Properties Data, adjunct to: ASTM D 1250-04 and IP 200/04.
The solution runs only in an SAP ABAP environment in which SAP Oil & Gas has been
implemented.
This solution can be accessed by the SAP Quantity Conversion Interface (QCI) or the
QuantityWare MQCI (Model based QCI) and is controlled by the provided conversion groups.
4/18
1. Installation
The technical implementation is provided as a part of a CSP package.
Please follow the standard SAP instructions for importing service packages into your system via
transaction SPAM.
Customizing settings, which are needed in every client in which this standard will be used, are
included in the delivery package.
On releases based upon SAP 4.72 and below, the related customizing transport must be
imported into all necessary clients, or distributed to them from client 000.
On releases based upon SAP ERP 2005 (ECC 6.00) or newer, BC Set /QTYW/BCP_10A must
be activated in the relevant clients.
Please refer to the QuantityWare BCP 10A Installation Guide for more information.
WARNING: If you import the customizing template into a pre-existing client, any
pre-existing entries listed within the template (transport or BC-Set) will be
OVERWRITTEN!
Changes within the SAP Oil&Gas QCI are delivered by SAP with notes 954553 and 958296.
You have to ensure that the enhancements within these notes are applied to your system
before testing of BCP 1.0A can be performed, as a basis for later use in production of BCP
1.0A.
5/18
Read the API Manual of Petroleum Measurement Standards (MPMS) Chapter 11.1 manual
carefully.
This standards implementation requires a 64-bit based floating point arithmetic system. SAP
has implemented 64-bit floating point Arithmetic since at least the R/3 3.1H Kernels.
Instead of the formerly known tables, six main procedures have been defined representing the
calculation types responsible for the table values calculation.
Since all calculations are internally based on 60 F, the metric based procedures always result
in a Type 3 calculation at 60 F.
We have defined new conversion groups based on the existing groups, which in turn are based
on the old API tables; this is important to note as the SAP QCI as well as the QuantityWare
Model based QCI (MQCI) is controlled by conversion groups.
6/18
There are several notable changes within the ASTM D1250-04 standard such as:
Density of water at 60 F
Temperature scale of 1990
Rounding and precision
Glass Hydrometer corrections
Pressure correction (0 PSI -> no pressure correction)
Temperature:
Pressure:
PSI
Density:
kg/m
1/F
7/18
Choose Thermal expansion factors and select F8 (Execute) to access the calculation tool:
8/18
Using different activities, you can create/copy material data for which you can enter laboratory
measurement results (densities at various temperatures) and then calculate the thermal
expansion factor.
9/18
4. Test Report
The ASTM D1250-04 test report can be easily accessed via the Petroleum Measurement
Cockpit:
Main Functions
1. Installation Test.
This is the default function when the report is called.
No further input is necessary.
All necessary functions will be checked, see (2), (3) and (4).
The report tests all calculation logic as defined by the standard and in addition, quantity
10/18
Report Details:
Selection Screen: Run installation test
11/18
12/18
13/18
14/18
If the results are correct, the example is marked with O.k., if an error is returned - with Error.
The total number of examples and errors is listed too.
If a protocol line is selected, all input and output data is shown, as well as the expected
results.
Diagram 2.2
15/18
16/18
The result is shown in a list (see Diagram 3.2). If any errors occur, all messages will be listed.
17/18
18/18