Sie sind auf Seite 1von 4

Smart Gas Meter Series

Reliable, tamper safe optical detection of measuring unit with Gray-Code


M-bus, wired or wireless, Zigbee RF and GSM data communication
Built-in valve for remote closing and safe opening of gas ow
Excellent accuracy, using error curve correction
Data logger for readings, alarms and events
Firmware updating Over The Air (OTA)
Secure AMR, using AES encryption
Built-in, temperature conversion
Battery lifetime up to 20 years

Display menu
COMMUNICATION

Exchangeable communication
module
Wired M-Bus EN13757-2
Wireless M-Bus 868 MHz og 169
MHz EN13757-3/4
ZigBee RF SAP 1,2
GSM / GPRS
Pulse out
Communication available in 2 versions:
o DSMR (Dutch Smart Meter
Requirement)
o OMS (Open Metering System)

OPTIONS

Wired M-Bus
Wireless M-Bus 169MHz
Wireless M-Bus 868MHz
ZigBee (2,4GHz)
GSM/GPRS
Pulse out

www.onidan.dk

Gray-Code detection system


The movement of the gas measuring unit is
detected by a unique, High Frequent optical
detection system, based on Gray-Code and 3
optical sensors on the PCB. This system offers
high resolution and a tamperproof and failsafe
detection, fit for instant flow calculation and error

Excellent accuracy

Error curve correction.

The initial error curve of the diaphragm gas meter is


programmed into the micro-processor in the index at 3
flows: Qmin, 0.2 Qmax and Qmax.
With the High Frequency Gray-Code detection, flow is
calculated and actual error calculated by linear
interpolation. The final error is hereby corrected to
approx. 0.1%.

Temperature conversion (option)


Temperature conversion may be performed for read out of base volume or energy.
A unique temperature measurement system ensures a precise determination of gas temperature inside the
measuring unit. This technique improves the accuracy with up to 3%, compared to conventional methods.

Logs

Security

Uniflo G4S electronic index have various logs,


depending on model:
Interval log (hourly, half hourly)
Daily log
Monthly log
Yearly log
Alarm log (several logs)
Event log
Configuration log
Billing log

Tamper alarm
Mechanical tampering of the index is not possible, as
moving parts in the index are reduced to a minimum.
Removal of front cover will activate tamper alarm. The
gas meter is not sensitive to normal magnetic fields. In
case of extremely powerful magnets, a magnetic tamper
alarm will be issued.
Safe communication
Communication is secured by encryption (AES) with
individual encryption keys, and by detection of invalid
communication format, an alarm is issued.
Reverse flow
Reverse gas flow will be stopped by mechanical lock in
measuring unit, and reverse rotation will be detected by
the Gray-Code and immediately activate an alarm.

Integrated valve (option)


The meter may be supplied with built-in valve, offering remote closing of the gas flow after receiving the signal from
back office.
The valve control system includes Safe Open, with customer intervention and flow control. Parameters for safe
opening are configurable.
Command for safe opening without customer intervention is also available.

AMR (Automatic Meter Reading)


The meter may be supplied with M-bus, wired (EN13757-2) (standard with 2m cable) or wireless (EN13757-4, short
distance radio frequency, 868 or 169 MHz), ZigBee radio (2.4 Ghz) or GSM/GPRS modem, for remote reading.

Upgradable rmware
The meter support remote upgrade of application firmware (OTA = Over The Air). If transfer of new firmware fails, or
self diagnostic function report failure, roll back to previous firmware version is supported. Metrologic (legal) firmware
will not be affected.

Multi function display


The meter support several multi function readings, such
as actual or converted volume read out switchable from
back office, and auto scroll between total, monthly,
weekly and daily consumption (EDL). For more
advanced read out possibilities, we offer a full menu
driven graphic display, with back light.

Standard index

Messages
The meter allows sending messages from Utility to Consumer.
The text will scroll over the display, until it is acknowledged.
Advanced index

Smart Gas Meter Series

TECHNICAL SPECIFICATIONS:
G1.6
G2.5
G4
G4
G6
G10
G16
G25

1)
2)

Vc
3
dm

Qmax
3
m /h
2.5
4
6
6
10
16
25
40

1.2
2.2
5
20

1)

Qmin
3
m /h
0.016
0.025
0.040
0.04
0.06
0.10
0.16
0.25

2)

Pmax
bar

P
mbar
0.8
1.1
1.4
1.4
2.0
1.7
3.0
2.8

0.5
0.5
1.0

Pmax.without valve / Pmax with valve 0.2 bar


Air, at Qmax.,without valve

Vc
3
dm

H
mm

W
mm

D
mm

d
mm

C
mm

1.2

206

214

157

66

110

1.2

229

200

159

67

1.2
1.2

267
220

235
282

169
168

2.2

225

327

2.2

265

G6

2.2

G6

G1.6
G2.5
G4
G1.6
G2.5
G4
G4
G4
G2.5
G4
G2.5
G4

G10
G16
G10
G16

T
mm
GM3/4"
G5/4
G7/8

M
kg

Mono

G2

2.1

72
72

152
220

BS1
GM3/4"

3.1
2.5

175

74

250

G5/4

3.2

237

172

73

Mono

G2"

3.2

281
276

326
326

182
182

79
79

220
250

GM3/4"
G5/4"

3.4

2.2

289

231

179

78

Mono

G2"

3.6

5.0

345

396

214

93

280
300

G2"

6.8

5.0

370

382

207

84

Mono

G2

5.6

20

443
481
469

457
547
457

289
330
289

138
158
138

335
400
Mono

G2"
G2"
DN50 .

13.3
13.6
14.2

G25

Ret til ndringer forbeholdes / Subject to change

Temperature range:
Tamb: -25+55C

Tgas: -25+55C

Type denition:

Battery lifetime:

15 years, calculated 20 years

Display:

Graphical display, menu driven


9 digits, 0, 3 or 4 decimals (congurable)

Approvals:
MID:
ATEX:

DK-0200-MI002-013-017
II 1/2G Ex ia/ib IIB T3
0044 10 ATEX 377834X

Conformity with:

EN14236:2007
SMETS:2013/2014 (UK)
EN12405-1:2006 (electronic index)
OIML D11(EMC) (electronic index)
Directive 94/9/EC (ATEX)

FLONIDAN A/S
Islandsvej 29 DK-8700 Horsens Tlf./Phone +45 75 61 88 88 Fax +45 75 62 60 88 www.flonidan.com

Flonidan A/S QM-System is ISO 9001:2008 certified by FORCE certification A/S


The information contained in this document is subject to change without notice.

M/0618000/03
Rev. 20.02.2014