TYPE 4860

WHEN QUALITY IS AN ISSUE, THE CHOICE IS TETTEX

ELECTRONIC HIGH PRECISION


S TA N D A R D V O LTA G E D I V I D E R S

I N S T R U M E N T S

TYPE 4860

ELECTRONIC HIGH PRECISION


S TA N D A R D V O LTA G E D I V I D E R S

GENERAL

A D VA N TA G E S

The electronic high precision standard voltage


divider is designed for use as a variable comparison
standard instead of an inductive standard transformer
for testing high-voltage instrument transformers. It
comprises a capacitive high voltage divider (compressed gas and air capacitors) and an electronic
device.

A universal comparison standard for setting any


transformer ratios within a wide voltage range.
Many instrument transformer types only require a
single standard voltage divider.
Very accurate ( 50 ppm 0.1 min) voltage divider
ratio settings.
Max. measurement voltage only depends on
compressed gas capacitor rated voltage.
Where voltage is less than 1000 V the electronic
device can be used without the capacitive voltage
divider.
Simple use.
A suitable standard for voltage instrument transformer measurement with all Tettex transformer
test sets (2767, 2765, 2711/22 and 2711/23) and
for test sets of many other makers.
The electronic device of series 4860 can directly
replace the earlier electronic device of series 4850
system.
Existing compressed gas capacitors can generally
be equipped to form a complete system.
The complete 4860 system voltage divider is
certifiable.
Remote control possibility via IEEE 488 or
RS 232C interface (optional).
The standard can be combined with a type 2767
transformer test set to form an automatic voltage
instrument transformer test system.
A more cost-effective solution than inductive
standard voltage transformers, especially for high
rated voltage systems.

S TA N D A R D
V O LTA G E D I V I D E R
ARRANGEMENT
High voltage divider unit
The high voltage divider unit comprises
a capacitive high voltage divider (compressed gas standard capacitor C1 and
air capacitor C2) and an electronic device in series, constituting a variable electronic divider (see system diagram).
Capacitive voltage divider C1/C2 divides
the primary voltage Uprim to voltage
U1, which the electronic device matches
to the required secondary voltage Usec.
Voltage instrument transformers of less
than 1 kV primary voltage can be
connected directly to the electronic
system via the adaptor box supplied
with the divider.

Electronic device
The main components of this system are
an input amplifier and a guard-potential
control (up to 1010 V), an electronic
divider and a power amplifier with the
output stage. The instrument is protected against setting errors, overvoltages
and short-circuits. Message errors are
indicated in the dot matrix.

Type 4861 standard version


This version has up to two fixed voltage
divider ratios set by TETTEX Instruments,
which the user cannot change. The
complete standard voltage divider is
therefore certifiable.

Type 4862 customized version


The user can set two different ratios
and change them whenever he likes.
This standard divider is not certifiable.

T E C H N I C A L S P E C I F I C AT I O N
Electronic system
type 4861 (4862)

General data
Power supply

230/115 V,

Input

50/60 Hz

Max. input voltage U1

1010 V

Power requirement

approx. 100 VA

Input resistance

> 10 G

Storage and transport

Input capacitance

< 0.1 pF

temperature

Measurement signal

20...+70 C

Dimensions

frequency

45...65 Hz

(W x H x D)

16 2/3 Hz on request

500 x 310 x 470 mm


(19.7 x 12.2 x 18.5)

Max. guard capacitance

10 nF

Weight

34 kg (74.8 lb)

(for guard potential control)

Error limits

Output
Max. output voltage Usec

250 V

Max. power output

Intrinsic error (electronic device)


In operating range 20...200 % U/UR

5 VA

Test frequency

0.4 A

At reference

50 or 60 Hz 1%

for U/UR = 100%


Max. output current
for Usec 50 V

conditions F = 50 ppm 0.1 min

Max. load capacitance

10 nF

System parameters
Rated primary voltage PV

At rated operating
conditions F = 100 ppm 0.2 min
Reference and rated operating conditions according to IEC 359, class I.

Input ranges:
Direct input

0.010...1.010 kV

With capacitive
divider

(0.010...1.010) x 1/CR [kV]

adjustment factors

x1, x1/3, x1/3

Important!
Max. measurement voltage = max.
permissible rated voltage of compressed gas capacitor.

Rated secondary voltage SV


Input range
Adjustment factors

5 ... 250 V
x1, x1/3, x1/3

Capacitive divider ratio CR


Input range
Resolution

1:1...1:10 4
110 -6

Additional errors
With extended operating range
5...20% U/UR
50 ppm; 0.1 min
1...5% U/UR

100 ppm; 0.2 min

With extended frequency range


45...65 Hz
50 ppm; 0.1 min
With capacitive divider
C-divider calibrated and supplied by
TETTEX Instruments as per standard
system table: no additional errors.
Existing type 4850 electronic device
replaced by type 4861: no additional
errors.
System calibrated and commissioned
by TETTEX Instruments on customers
premises: additional errors on enquiry.

B A S I C T E S T S E T- U P

series 3370 NK/ D


C1

type 4861
electronic device

Uprim

uN
vN

mains ground

Legend for abbreviations used

U/UR

Capacitive divider ratio


CR = 1 :

C1 + C2
C1

= 1 :

PV
SV
CR

200%

Uprim
U1

Excitation

UR

Uprim
PV

Usec
SV

Rated primary voltage


Rated secondary voltage
Capacitive divider
ratio (C-Ratio)
Primary voltage
Secondary voltage
Electronic divider
input voltage
Test voltage
(primary or secondary)
Rated voltage
(primary or secondary)
Excitation

Uprim
Usec
U1

100%

to instrument
transformer
test set

U1

series
3330/

C2

Usec

0
0

50%

100%

UR (PV, SV)

U
UR
U/UR

Series 3370 compressed gas standard


capacitors (C1)

Series 3330 air capacitors (C2)

Technical specification as in leaflets 3370 NK.


The low-voltage connection is provided with a triaxial
socket for use of the capacitor as a capacitive voltage
divider (series 3370/...D.

Max. operating voltage (rms)


Capacitance values

Triaxial/coaxial adapter no. 008140-72


enables C/tan measurements.

Dimensions
(L x W x H)
Weight

1000 V
1900...10,000 pF

360 x 360 x 450 mm


(14.2 x 14.2 x 17.7 in)
2000 pF 24 kg (52.8 lb)
4000 pF 27 kg (59.4 lb)
5000 pF 29 kg (63.8 lb)
10000 pF 35 kg (77.0 lb)

E L E C T R O N I C S TA N D A R D V O LTA G E D I V I D E R
S E R I E S 4 8 0 0 S TA N D A R D S Y S T E M S
Standard system

Measurement range
(Primary HV)

Compressed gas
standard capacitor C1

Air capacitor C2

C divider ratio CR

Type
[Series/pF/kV]

Type
[Serie/pF]

CR = 1: (C1 + C2)/C1

3370NK/100/100 D

3330/9900

1:100

without

without

1:1

2 200 kV

3370NK/100/200 D
3330/9900

3330/10000 +

1:200

1 100 kV

3370NK/100/200 D

3330/9900

1:100

without

without

1:1

3 300 kV

3370NK/50/300
3330/4950

3330/10000 +

1:300

1 100 kV

3370/50/300 D

3330/4950

1:100

without

without

1:1

3370NK/50/400 D
3330/9950

3330/10000 +

1:400

without

without

1:1

3370NK/50/400 D
3330/9950
3370NK/50/400 D

3330/10000 +

1:400

3330/4950

1:100

without

without

1:1

3370NK/50/600 D
3330/9950

3330/10000 (2x) +

1:600

without

without

1:1

6 600 kV

3370NK/50/600 D
3330/9950

3330/10000 (2x) +

1:600

1 100 kV

3370NK/50/600 D

3330/4950

1:100

without

without

1:1

3370NK/50/800 D
3330/9950

3330/10000 (3x) +

1:800

without

without

1:1

8 800 kV

3370NK/50/800 D
3330/9950

3330/10000 (3x) +

1:800

1 100 kV

3370NK/50/800 D

3330/4950

1:100

without

without

1:1

Type

4861/100

1 100 kV
10 1010 V

4861/200

10 1010 V
4861/300

10 1010 V
4861/400a

4 400 kV

10 1010 V
4861/400b

4 400 kV
100 kV
10 1010 V

4861/600a

6 600 kV

10 1010 V
4861/600b

10 1010 V
4861/800a

8 800 kV

10 1010 V
4861/800b

10 1010 V

O R D E R S P E C I F I C AT I O N
Options

Standard voltage divider as per standard


system type series 4860, comprising:

IEEE 488 interface


Cable data-links for:
-IEEE 488 interface, 4m
-RS 232C interface, 3m
-RS 232C interface, 30 m
(fibre optic data-link)

Electronic device
Type 4861
Compressed gas standard
capacitor
series 3370*
Air capacitors
series 3330
Adaptor box for direct
connection,
no. 014235-00
Measuring cable, 10 m
no. 014107-00
Measuring cable, 1.5 m no. 013685-00
Measuring cable, 0.5 m no. 014108-00
Ground cable,
16 mm2, 10 m
no. 016351-00
Power cable
Triax/coax adapter
no. 008140-72
for compressed gas standard capacitor
(for C/tan measurement)
RS 232C interface
type 4861/2
Power voltage
(please specify with order)

type 4861/1
type 5993
type 5991
type 5992

Replacement of series 4850


electronic device by type 4861
The connections are compatible with the
existing unit. Determine and set the capacitive divider ratio.

Important!
Adaption and comissioning of the standard voltage divider by TETTEX Instruments
is essential to ensure its required accuracy.

230 or 115 V,
50/60 Hz

*) The compressed gaz capacitor has to be


ordered separatly.

TYPE 4860

Standard supply

E191.90
Subject to change
without notice 03.00

Haefely Test AG
Tettex & Haefely EMC Division
Bernstrasse 90, P.O. Box
CH-8953 Dietikon - Zurich
Switzerland

www.tettex.com

Phone: +41.1.744 74 74
Fax.:
+41.1.744 74 84
e-mail: sales@tettex.com