Sie sind auf Seite 1von 62

Emirates Lime Factory

Tangshan Tianheng Automation Institute


Tangshan Institute of Automation of balanced
Packing controller
Technical Manual
Tangshan Institute of Automation of balanced
Note: The manual using bold italic and underlined parameters or
instructions need to be carefully read
Reading, according to the actual situation in the commissioning
appropriate modifications to adjust.
Tang Dynasty

1, the main features


l Small size based on DIN specifications

As XK3201 (F701D) is DIN200 X 100 size, XK3201 (F701B) is DIN166 X


88 size, suitable for embedded Into the instrument box.
References: Chapter 4 instrument setup.
l High maneuverability
Using a high frequency of use and purpose of six function keys, 10 keys
preferred form, with good operability.
l Data Calibration
Operate only on the front panel with a button you can easily perform
the digital calibration function.
l timing control function
The controller can control many forms of quantitative scale, as with the
feeding, fast feed, in feed, fine feed, discharge, clip loose bags,
Shoot bags motion control, with a bucket packaging scales, no bucket
packaging scales, cumulative scales with flow control valve orifice
scales, quantitative reduction scale, dual combination of scale,
Filling scales and other timing control function, no external program
generator.
l Supply voltage range
The power supply voltage can be in the range of 187 ~ 242V choose to
use.
l External Interface rich (with selected when ordering)
Through Communication output, RS-232C or RS-485, D / A converters
can be easily loaded with a PC or a program generator
Ministry device.
Please refer to: Serial interface RS-232C, RS-485, D / A
converter.
l self-test function
Internal self-test function with the instrument, a warning of abnormal
self-test function and self-test on the input and output, greatly facilitate
the instrument
Operation and maintenance.
See also: self-test function.
l filtering
With a filtration mechanical vibration filtering (digital filter).
l debug parameter save
Protected with an area code debugging parameter save. And can be
carried out in the time needed to restore a saved debugging
parameters for recovery.
l production process prompts
The instrument has in the production process through the character
and the cursor tips can know the current state of the device.
l alternate output switching function
Output port switching the instrument with more and more powerful
features, and to improve the instrument's high reliability guarantee.
l cumulative function

Instrument has a pair of batch classes cumulative production, total


production accumulated power-down protection.
Tangshan day value since
2, before use
l Please check whether there is damage during transportation.
After receiving the product, please open the package check whether
there had been in transit damage.
l Please confirm specifications
Affixed in front of the contents of the specified record label, make sure
the label record.
l Please confirm Accessories
(1) Terminals (7) ----------------------------------------- ------------------------------ 1
set
(2) XK3201 (F701B / D) -------------------------------------- manual or CD-ROM
-------------- 1
(3) Packing List -------------------------------------------------------------------------------------- 1
(4) certificate -------------------------------------------------------------------------------------- 1
XK3201 (F701B / D) in the Company's factory stringent checks carried
out to ensure the mechanical and electrical
Sexual functioning normally. If external damage or can not complete
the required specifications as specified action,
Please contact the company or purchased at the contact of the
company or agency.
l transporting the instrument or to return it to the company for repair,
please click the following methods for packaging.
* If you save the time of delivery of the company's packaging materials
(A) the instrument with the same state as the original packaging
placed into cardboard box.
(2) Close the lid of the carton, closed the lid with a wide adhesive tape
seams.
* If you use the packaging materials.
(A) in the use of the instrument into the box before the strong
Loading paper or plastic paper wrapped.
(2) To use the cardboard box, from its size to ensure that the
instrument
There are about 10 cm each side of the gap.
(3) in a gap between the box and the instrument to be inserted into the
adequate
Cushioning foam, and then close the box cover,
Closed the lid with a wide seam tape
3, the safety precautions
Using this instrument, please note the following:

l instrument ground
To prevent electric shock and static electricity damage, be sure to put
on the rear panel of the E terminal is grounded.
E terminal with access to the internal AC power noise filter ground
terminal and the chassis are connected.
l use in hazardous locations
Do not use in flammable gas or dust not use this instrument, posing a
fire hazard. Being considered dangerous place to use this
Instrument, please contact the company.
l Power
The instrument's power in AC187 ~ 242V (respectively, 50/60Hz) range
transformed. Maximum power consumption is 20VA. In Power
Use on an unstable state, it is recommended to use the regulator.
l Operating temperature, storage temperature
The instrument's operating temperature range is -10 ~ +400 C.
During storage, -40 ~ +800 C in the range of custody.
4, the instrument installation
Follow these steps to XK3201 (F701B / D) mounted to the instrument
box.
(A) a hole in the installation instrument case.
Instrument box hole size: XK3201 (F701B): 150 WX 75H (mm)
XK3201 (F701D): 186WX 92H (mm)
(2) Remove the gauge mounting rails on both sides, the gauge into the
instrument box.
Pressure self-tapping screw chassis
Tight rail
Top tight rail into
Slot chassis
Screws
Top tight rail
Top tight rail
(3) from the back of the gauge into the gauge mounting rails on both
sides.
(4) supplied with the instrument, 3mm screws firmly fixed on both
sides of the mounting tabs.
Note that
Handling equipment box after installation, please be careful not to
apply excessive shock and vibration.
Tangshan
5.2, XK3201 (F701B) instrument shape and hole size
XK3201 (701B) Dimensions

6, the names and functions of each part (front panel)

6.1, weighing several display instructions


Section 1: The instrument operating status prompt.
Section 2: No display sign bit positive number indicates the number of
weighing. Sign bit display - indicates a negative number for weighing.
Figure: No display indicates the number of positive weight. The
weighing number is negative.
No. 34567: For weighing display numbers and error messages prompt.
6.2, the status display block
Display block
There are 7 Table 3 shows the block its function
6.3, zero offset Indication (d indexing the minimum display value)
6.3.1, when the display weight deviation: Display Weight | d | lights
when O (d for the division value)
6.3.2, when the display weight deviation: d 0, weight display
indicator flashes.
6.3.3, when the display weight deviation in:-d display weight 0,
indicator flashes.
6.4, backup battery power display description (not used)
Backup battery level indicator, low battery symbol is flashing, you need
a new battery.
The display symbol has three states: off, put out, blinking.
6.5, weight unit display (there are five)
Select the weight unit t t, Kg kg, g g, Ib lb, N cattle

t t g g Ib lbs Kg kg N Newton
6.6, F1 ~ F16 displays the Run status indicator
Operational status indicator light indicates the working status of the
meaning of Table
Status display (bright) Meaning status display (bright) Meaning
F1 shutdown state F9 OUT3 fast charging status
F2 emergency stop feeding status in F10 OUT4
F3 IN4 (there is material on the material level state) F11 OUT5 slow
charging status
F4 IN5 (scales door closed position) F12 feeding state compensation
F5 IN6 (cut valve open position) F13 finished feeding
F6 IN7 (folder bag request) F14 OUT7 enjoys door status
F7 IN8 (folder bag in place) F15 racket bags state
F8 OUT1 state F16 OUT8 on feeding tolerance alarm status
6.7, the menu display types and functions (a total of 16 digital display
as shown below)
6.7.1, the initial standby
Before 4 Show "PPon" (rear is an arbitrary number) as shown below;
Tang Dynasty
6.7.2 runtime menu display
There are five types, as shown below; (the first one is the serial
number)
1, species number, the actual target amount, duty batch accumulated
error value. As shown below;
2, the flow rate, the cumulative yield on duty. As shown below; (the
first one is the serial number)
3, the actual target volume, total accumulated value. As shown below;
(the first one is the serial number)
4, the zero range, the upper limit, lower limit. As shown below; (the
first one is the serial number)
5, the date and time. As shown below; (the first one is the serial
number)
6.8, set the key features introduced
6.8.1, setting key
Variety No. 0 to 9 for setting the number of quantitative key.
F conversion setting mode with the function key.
Confirm / Enter for determining the setting items and setting values
confirm / enter key.
6.8.2, the function keys
Print this key to print and to set up parameters for the scroll key;
Cumulative
To view this key clears accumulated and set parameters in a
downward scroll key;
School scale calibration scales

This key is key, zero and full-scale calibration, the set parameters
can be used for right shift key;
Tare / cancel state in a non-set tare key; in a set operation of the key is
"Cancel" button.
Tang Dynasty
7, rear panel and wiring
7.1, XK3201 (701D) names and functions of the rear panel;
8, wiring methods
8.1, serial communication port and D / A output socket
Serial communication port (see Figure)
RS232C/RS485 output using standard interfaces.
(Ordering please specify yes RS232C or RS485)
3 Feet: RS232C Data (TXD) or RS485 output terminal A;
4 Foot: RS232C command data (RXD) input or RS485 B side;
Pin 1: RS232C COM terminal to ground
Communication port analog output jack number
7 foot: Analog + Output
9-pin: Analog outputs
Analog output (optional) Technical Specifications
Resolution: 1/4000
Output: 0 ~ 5V / 4 ~ 20mA
Maximum load resistance: 5K
Accuracy: 0.1%
When the display value is zero, then the output: The voltage is 0V or
4mA (specify when ordering is voltage-or current).
When the display value is the maximum range, the output: The voltage
of 5V or 20 mA.
When the negative, then the output remains, the voltage is 0V or
current is 4mA.
8.2, the sensor input signal wiring instructions
Pin Terminal Name Meaning
SIG +: Signal Input +
SIG-: Signal input SEN +: excitation feedback voltage input +
SEN-: excitation feedback voltage input EXC +: excitation voltage output +
EXC-: excitation voltage output SHLD: shielded cable
Sensor Connection
XK3201 (F701B) instrument is supplied to the sensor supply voltage
10V, current up to 120mA, up to four parallel
350 load sensor wiring are summarized as follows;
6-core shielded cable connection method.

Connect the sensor cable to try to avoid strong interference signal


source, such as a strong electric power lines, power equipment, wiring,
electromagnetic interference
Sources.
4-wire connection method generally used in the sensor connection is
shorter, less interference sources occasions. Wiring method is as
follows;
Note: You must put the same polarity, short Exc and Sen met the
following figure.
Sensor parallel method
In industrial measurement references, often composed of several
sensors in parallel hopper scales, truck scales, with its connection
Mode as shown below.
Cable shield
1
4
2
3
8.3, then plug the AC power supply wiring instructions
L-phase line, then AC 220V phase.
N zero line, power transformer centerline (commonly known as the
220V "ground").
E grounding resistance should be less than 4 ohms (To prevent
lightning accidents and electrostatic interference
Caused the accident, please be sure that E terminal grounded). Usually
three wiring lines
Yellow and green color line.
8.4, chassis ground
Chassis ground terminal. To prevent electric shock and static electricity
damage
Make sure the rack is grounded. Grounding resistance is less than 4
Grounding conductor should be greater than 0.75mm2 multi-strand
copper wire.
Right is connection diagram
8.5, the input port
Input port of 13 (input plug) shown below;
Input from an external power supply, connected with the CPU through
the optocoupler, external input a variety of methods,
1 switch 2. Relay contacts 3. Lock button 4. Transistor emitter follower
5. TTL level
Five Ways connection method as shown below; optocoupler input
current 6ma between 4.5 ~ 6ma actual selection.
Often used in a total of 13 inputs IN1 ~ IN10 features below; IN11 ~
IN13 an alternate port.

8.6, an output port


A total of 25 output ports are arranged below shows the position;
[XK3201 (701B)] is only 13 outputs.
OUT1 ~ OUT9 as outputs, OUT10 ~ OUT25 an alternate port, arranged
location shown below;
Actual use of the instrument of nine, the remaining 16 as a backup.
Output port with relay contact output, contact current is not too large
(Controlled at less than 1A), in order to avoid interference or contact
sparks burned contacts. Must be used with an external device
connected to the intermediate relay bridging. External
Device driver is supplied by an external power supply. Driven
equipment should be connected to the spark controller. The equivalent
circuit is as follows;
For ease of installation, the connector of the rear panel connectors are
used the way. As long as all the plugs connected into the rear panel of
eleven
To socket connection method if pressed with a small screwdriver
unscrew the screw clamp firmly on the line. See below;
9, keys on the
XK3201 (F701B / D) There are two key setting function, one for special
features dedicated keys set; another set for the parameter setting
keys.
9.1, the use of dedicated keys
9.1.1 Print print and scroll function keys.
This key has two operating functions
1: Set in the non-state press Print button, you can turn look at
the single-screen display of 1 to 5 kinds of content (by increasing order
scroll);
2: You can enter the set state, press Print button, select the
desired species and print content. [See print method of operation]
9.1.2 Cumulative accrued and scroll function keys.
This key has two operating functions
1: In non-set state accumulated by ] key, you can turn look at the
single-screen display of 1 to 5 kinds of content (press minus ordering
scroll);
2: You can enter the set state accumulated by ] key, you can view
the contents of all varieties accumulated, and through a password
clear the selected content.
[See View and clear the cumulative method of operation]
9.1.3, u school scale calibration scales and shift function keys.
This key has two operating functions
1: In non-school scale state by setting parameters school scale u
key to select the desired setting parameter data bits;
2: You can enter the set state press school scale u] key, and can be
set via a password to enter the school scale functions. [See school
scale method of operation]

9.1.4, peeled / Cancel] key has two functions:


1 In standby mode, press the key role played peeled.
2 in the command operation, as the exit the function key.
By * F2-5 * Function keys to disable the setting, the setting can be
prohibited dedicated key
9.2, setting key usage
Setting key is mainly used for parameter settings, at work can easily
and quickly set up a direct key people required data.
9.2.1, the setup process
Changing the parameter setting process:
[F] [[OK / Enter] [mode numbers 0 to 9 [[OK / Enter] [item number
from 0 to 9 [[confirm / enter
Entry] [parameter settings
Mode is set, then set item number (0 to 9) combined list is as follows;
Mode 0 Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 Mode 6 Mode 7 Mode 9
1
0-1
Upper limit
1-1
Compare ban
Time
2-1
Weighing Function 1
3-1
School scales password
4-1
D / A output
Mode
5-1
Alternate Function
6-1
Feeding on
Delay time
7-1
Shoot the feed bags
Start weight
9-1
Clock Set
2
0-2
Lower limit
1-2
Stability determination
Time
2-2

Weighing function 2
3-2
Range
4-2
D / A Zero
Weight
5-2
Output options
6-2
Discharge delay
Lockup
7-2
Shoot the feed bags
Stop Weight
9-2
Print Settings
3
0-3
Zero range
1-3
Weighing completion signal
Output time
2-3
Weighing function 3
3-3
Smallest scale
(D)
4-3
D / A full-scale value
5-3
A / D sampling
6-3
Discharge door
Off time
7-3
The default batch
4
0-4
PCWORD amount
1-4
Compensation to invest time
2-4
Continuous (Sequence)
Mode
3-4
NW overweight

4-5
RS-485
Mode setting
5-4
Display test
6-4
Auto Tare
Time
7-4
Loose bags Views
5
0-5
Jog volume
1-5
Auto Tare
Detection times
2-5
Function keys disabled
3-5
Total weight overweight
5-5
ID number
5-5
Keyboard detection
6-5
Folder bag time
6
0-6
Air volume
1-6
Determine the ultra-poor
Frequency
2-6
Digital filtering
Frequency
3-6
Digital Zero Fan
Around the specified value
(Go Pifan
Wai)
4-6
RS-232C
Mode setting
5-6
Input Detection
6-6

Delay start
Racket bags Time
7-6
Traffic Views
7
0-7
Tolerance
1-7
Determine the number of stable
Automatic fall slowly into compliance
Set limits
2-7
Motion detection
3-7
Function selection
4-7
External functions
Choose
5-7
Output detection
6-7
Delay loose bags
Time
8
0-8
Flow value
1-8
Analog filtering
2-8
Zero tracking
3-8
PCWORD automatic loading
Provided extremely poor
Limits
6-8
Loose bags Output
Time
9-8
Save debug parameters
And restore parameters
9
0-9
Target amount
1-9
Weight of the container
Tolerance

2-9
Setting LOCK
3-9
Fast forward automatic loading
Provided extremely poor
Limits
6-9
Racket bags parameters
9-9
SMB Select
00-0
Variety No.
1-0
Tare function selection
9.2.2 Example (prohibition compare time = 1.0 seconds) set-up
process:
1, enter the parameter setting, press F] key, the menu screen
display:
2, according to Confirm / Enter] key, the menu screen display:
3, select Mode 1, press 1 key, menu screen display:
4, press Confirm / Enter] key, the menu screen display:
5, select Settings prohibit compare Time Item 1, according 1 key,
menu screen display:
6, press Confirm / Enter] key, the menu screen display:
7, set the time to 1.0 seconds compared prohibited by 1 key, menu
screen display:
8, according 0] key, the menu screen display:
9, press Confirm / Enter] key to save the set parameters, the menu
screen display:
10, then select Mode 1 setting of other parameters, such as the exit
ban compare time setting state press peeled / Cancel] key, the menu
screen
Show:
11, then re-select any mode, such as exiting the parameter setting
state press peeled / Cancel] key, the display returns to the menu
screen before setting state.
Comparing steps above prohibition time setting value of the input.
Other settings can also use the same method to enter.
Tangshan automation of balanced
10, the setting table
Set the form 0
F OK to enter 0 OK to enter
Settings
Project

Children
Eye
Name Initial Value debugging values LOCK1 LOCK2 LOCK3 display only
Show
A cap 50000
2 limit 00000
3 Near Zero 0.5
4, into the amount of 10.00
5 the amount of 5.00 jog
6 air volume 0.3
7 Tolerance 0.05
8 flow value 0000000
9 target amount 25.00
0 0 No. varieties
Setting form a
F OK OK to enter into a
Settings
Project
Children
Eye
Name Initial Value debugging values LOCK1 LOCK2 LOCK3 display only
Show
1 Comparison Inhibit Time 0.8
2 air volume down 0.8 given time
3 Weighing completion signal output
Between
1.0
4:00 immobility time 0.0
5 peeled cycle 01
6 times 01 ultra-poor judgment
7 Slow automatically fall into the specified
Limits
1.00
8 analog filtering 2
9 container weight tolerances 00%
Tare function 00
D2 accept keys peeled condition 0
0
D1 peeled range 0
Tangshan automation of balanced
Set the form 2
F OK to enter two OK to enter
Settings
Project
Children

Eye
Name Initial Value debugging values LOCK1 LOCK2 LOCK3 display only
Show
Weighing Function 1 01010
D5 canned known as Weight and Tare choice 0
D4 control the scale body type Mode 1
D3 actual target volume and tolerance comparison 0
D2 upper / lower limit compare mode 1
1
Comparison of zero range D1 0
Weighing Function 2 00011101
D8 Level Level Select 0
D7 operating mode selection 0
D6 folder bag in place of the level selection 0
D5 anxious Song selection 0
D4 cumulative command to select a
D3 racket bags mode selection 0
D2 feed mode selection 0
2
D1 weighing complete output mode 1
Weighing function 3 0011
D4 air volume automatically trimmed amplitude 0
D3 whether to allow air volume automatically trimmed 0
D2 air volume automatically trim the number one
3
D1 peeled whether to allow a
Continuous (sequence) pattern 111000
D6 whether to allow empty enjoys Door 1
D5-tolerance whether to allow a discharge
D4 mode selection 1
D3 jog compensation input is allowed 0
D2 jog just at the beginning of the end point detection whether weight
0
4
D1 starting point is detected zero range 0
Function keys disabled 1110
D4 peeled Clear key is valid one
D3 school scale key is valid one
D2 key is valid a cumulative view
5
D1 print key function is active 0
6 times 32 digital filtering
7 Dynamic detection 0.5-02
Eight zero tracking 0.5-02
Setting LOCK 011
D3 LOCK1 0

D2 LOCK2 1
9
D1 LOCK3 1
Set the form 3
F OK to enter into the three identified
Settings
Project
Children
Eye
Name Initial Value debugging
Value
LOCK1 LOCK2 LOCK3 display only
Show
A school scales password 1234
2 Maximum Range 99.99
3 smallest scale 001
4 NW overweight 99.99
5 Gross weight overweight 99.99
6 digit zero range specified value (zero range) 2.50
Function select 13203
D5 auxiliary display content selection 1
D4 display refresh frequency 3
D3 decimal place 2
D2 1/10 scale body-resolution display is valid 0
7
D1 Weight Unit 3
8 automatically drop into the limits specified in 5.00
9 Fast forward automatically drop the limits specified 8.00
Set the form 4
F OK to enter 4 OK to enter
Settings
Project
Children
Eye
Name Initial Value debugging values LOCK1 LOCK2 LOCK3 show only
1 D / A output mode 3
2 D / A Zero Weight 0.00
3 D / A full-scale value 25.00
4 D / A spacing adjustment 0000
5 ID No. 01
6 RS-232, RS-485 mode setting 31011
D5 Baud Rate Selection 3
D4 Data Bit 1
D3 parity bit 0
D2 1 stop bit

D1
7 External function selection 1120
D4 sentenced filtering times when a steady
D3 sentenced steady motion detection mode 1
D2 peeled switch mode 2
D1 hand loose bags automatically select 0
8
9
Set the form 5
F OK to enter five OK to enter
Settings
Project
Children
Eye
Name Initial Value debugging
Value
LOCK1 LOCK2 LOCK3 show only
An alternate function 00
Output Selection 6498
D4 OUT13 output line feature set 6
D3 OUT12 output line feature set 4
D2 OUT11 output line feature set 9
2
D1 OUT10 output line feature set 8
3 A / D sampling
4 shows the detection
5 keyboard detection
6 input detection
7 output detection
8
9
Set the form 6
F OK to enter six OK to enter
Settings
Project
Children
Eye
Name Initial Value debugging
Value
LOCK1 LOCK2 LOCK3 show only
A delay time of 5.0 feeding on
2 discharge delay closing time 1.0
3 discharge doors closing time 0.5
4 automatic tare time 2.0
5 Time 0.3 folder bag

6 hours delay start shooting bags 0.5


7 Delay Time 0.5 loose bags
8 output time 0.0 loose bags
Shoot bags parameters 00-0.2-0.5
D3 racket bags Hits 00
D2 racket bag pulse time 0.2
9
D1 racket bags inflated Time 0.5
Set the form 7
F OK to enter seven OK to enter
Settings
Project
Children
Eye
Name Initial Value debugging values LOCK1 LOCK2 LOCK3 display only
Show
A feed bag starts shoot weight 0.00
2 bags of feed end of shoot weight 0.00
3 Preset Batch 0000
4 times 00 loose bags
5
6 times 00 average flow
7
8
Set the form 9
F OK to enter 9 OK to enter
Settings
Project
Children
Eye
Name Initial Value debugging values LOCK1 LOCK2 LOCK3 display only
Show
A clock setting
2 print mode setting 1-1-00-00
D4 choose a printer
D3 select a print mode
D2 Print hour setting: 00 to 2300
D1 Print minute setting: 00 to 5900
3
4
5
6
7
8 Save the debugging parameters and restore parameters 0
9 Select backup board
* Initial value: factory setting

* LOCK1: through the soft switch (setting) prohibits setting changes.


(Stored in the backup RAM)
* LOCK2: through the soft switch (setting) prohibits setting changes.
(Stored in the NOV.RAM)
* LOCK 3: through the soft switch (setting) prohibits setting changes.
(Stored in the NOV.RAM)
* Only: You can not make configuration changes.
Tangshan days
10.1 Setting Mode 0 [setpoints Detailed]
Setting mode 0 is used to set quantitative feed / discharge control
setting mode.
l For example: take cap is set to "8000."
F Confirm / entry 0 confirm / enter the selection mode 0
1 confirm 0 8 0 0 0 confirm / enter
Weight data (5)
Press TARE / Cancel key exit the setup, complete the operation.
1, the upper limit F-0 -1 (00000 ~ 99999)
Upper limit setting, the direct number buttons to enter the weight
2, the lower F-0-2 (00000 ~ 99999)
Set the lower limit, the direct number buttons to enter the weight
3, the zero range F-0-3 (00000 ~ 99999)
Zero range setting, the direct number buttons to enter the weight
4, the feed amount F-0-4 (00000 ~ 99999)
PCWORD volume settings, direct numeric keys to enter the weight
5, a jog volume F-0-5 (00000 ~ 99999)
Jog volume settings, direct numeric keys to enter the weight
6, the air volume F-0-6 (00000 ~ 99999)
Headspace volume settings, direct numeric keys to enter the weight
7, tolerance F-0-7 (00000 ~ 99999)
Tolerance setting, direct numeric keys to enter the weight
8, the flow value F-0-8 (0000000 ~ 9999999)
Flow rate setting, direct numeric keys to enter the weight
9, the target amount of F-0-9 (00000 ~ 99999)
Target volume set, direct digital key input weight
0, Variety No. F-0-0 (0 ~ 9)
No. varieties set, direct digital key input weight
10.2 Setting Mode 1
Setting Mode 1 is to set the quantitative feed / discharge control timing
mode and the output signal of the parameters in the mode.
l For example: take off the air quantity given time to 0.5 seconds.
F Confirm / Enter 1 confirm / enter the selection mode 1
2 confirm 0. 5 confirm / enter
Air volume settled time (2)
Press TARE / Cancel key exit the setup, complete the operation.

1, prohibits compare time


F -1 - 1 0.8
Current time is 0.8 seconds compared ban
Compare time prohibited the range of 0.0-9.9 seconds, when OUT3,
OUT5 output when there is a period of time to make any comparison
prohibit weight data,
Press the number keys to directly modify the parameter. When the
storage bin hopper to said initial supply of materials and end the
supply of materials, due to the impact of the material and arrest,
Said hopper will thus produce jitter oscillation of the instrument display
is unstable, especially in light of weighing hopper design, when the
initial material into said hopper,
The role of the gravitational acceleration, said hopper receiving the
signal will be greater than the weight of the actual weight of the
material, so during this time, can be taken to stop the
Sampling time prohibited comparative methods to improve the
accuracy of the displayed value.
2, the amount of air time settled
F -1 - 2 0.5
Air volume settled time, ranging from 0.0-9.9 seconds, press the
number keys to directly modify the parameter.
3, Weighing complete signal output time
F -1 - 3 1.0
Weighing completion signal output time: in the range 0.0-9.9 seconds,
the signal output time; 0.0 no signal output
4, jog time
F -1 - 4 0.0
Jog time, ranging from 0.0-9.9 seconds, press the number keys to
directly modify the parameter.
5, automatic return to zero frequency (peeled cycle)
F -1 - 5
Auto-zero frequency (valid only for continuous mode), the number of
auto-zero time scales (peeled cycle). The range of 00-99 times
6, check the number of ultra-poor (depending on whether you need to
have tolerance function setting)
F -1-6 01
Check the tolerance number (valid only for continuous mode), which
checks the number of ultra-poor. Ranging from 00-99 times.
Determine the number of "00": When the jog after skipping air volume
stability judgment time, the contractor steady, ultra-poor compared to
cumulative production (packet times to be tired
Meter), slow forward compensation, the amount of compensation the
air and sentenced to a folder bag in place enjoys a door marked
immediately discharge.

Determine the number of "01": after the end of each scale jog be
sentenced - air volume stabilization time, the contractor steady, ultrapoor comparison, cumulative output, Slow Forward
Compensation, the amount of compensation the air and sentenced to a
folder bag in place enjoys a door marked discharge.
Determine the number "02" is: Every two scales slowly into the end
shall be sentenced - air volume stabilization time, the contractor
steady, ultra-poor comparison, cumulative output, Slow Forward
Compensation, the amount of compensation the air and sentenced to a
folder bag in place enjoys a door marked discharge.
And so on.
7, Slow automatically fall into the limits specified
F -1-7
Slow automatically fall into the limits specified in the range 0-99999,
when the final weight value compared with the target amount, the
difference is greater than this value can not be
Basis for the correction.
8, analog filtering
F -1-8
Analog filtering in the range 0-3, select the corresponding 0,1,2,3
2,4,6,8 Hz frequency interference method for selecting analog filtering.
9, the container weight tolerance
F -1 - 9
Container weight tolerances in the range 0-99, the percentage weight
of the container allowable error in filling scales used, after a container
is placed on the scale,
In this setting the percentage range of error allowed to continue
working.
0, peeled function selection: Tare function parameter limit of 2, D2, D1,
respectively:
F -1 - 0
D2: accept a key condition peeled D1: Tare Range
1: Only in stabilization time before accepting a: 0 < zero range tare
0: Normal accepts 0: all ranges
10.3 Setting Mode 2
Set Mode 2 is used for tuning XK3201 (F701B / D) and the internal
functions of the display setting mode.
For example: take digital filter is set to 32 times.
F Confirm / entry 2 confirm / enter the selection mode 2
Press 6 confirm 0 3 2 confirm / enter
Digital filtering (3)
Press TARE / Cancel key exit the setup, complete the operation.
1, weighing function 1
F -2 - 1
D5: In filling scales in Weight and Tare choice

1: Gross weight scales


0: Weight Scales
D4: control scale body type pattern D1: Comparison of zero range
9: Control valve port Scale 1: do not compare
8: t packing scale 0: | Current weight | zero range
7: Quantitative reduction scale
6: Two-scale B D2: upper / lower limit comparisons
5: Double Scale A 1: do not compare
4: Flow Cumulative Scale 0: Comparison with the current weight
3: Filling Scales
2: No bucket packaging scales
1: bucket packaging scales
0: Normal input scales
D3: quantitative and ERRORS (tolerance) Comparison
1: do not compare
0: Compare
D1: Zero range comparison (explanation)
1: Do not compare (mainly used for electric scales Door Program
control: When the output enjoys the door after the first sentence
discharge delay closing time, and then
Sentenced to closed position signal (closed position signal judged
longer than 50ms) after the withdrawal enjoys a gate output, delay
discharge doors closing time sentenced to
Leather cycle backward material);
0: | Current weight | zero range (mainly for pneumatic scales Door
Program control: When the output enjoys the door, the first sentence is
less than zero range
, Then delay the discharge delay time withdraw enjoys close the gate
output and sentenced closed position signal is valid, discharge doors
closing time delay period after contracting peeled
Feed.
Note: you will need after a work stoppage scale body type switching
control mode to be effective.
2, weighing function 2
F -2 - 2
D8: Level Level Select
1: active high
0: Active low
D7: operating mode selection
2: folder bag and bag clip into place automatically after the start (valve
port scales used)
1: level starts (ie after receipt of IN1 started; receive IN1 downtime)
0: pulse level started (ie, IN1 started; IN2 downtime)
D6: folder bag in place of the level selection
2: Pulse active low (folder bag in place once the signal to be effective,

Valid once, to enter the second judgment).


1: active high
0: Active low
D5: Urgent loose selection
1: No discharge before the two-time folder bag request emergency
loose bags feature
0: No discharge before the two-time folder bag request without
emergency function loose bags
D4: Cumulative command selection
1: Allow the cumulative
0: not cumulative
D3: shoot Bag Mode Selection
2: There are bats feed bags
1: After the shooting said the finished material bags
0: No bats bags
D2: Feeding Options
3: Fast speed in slow three separate feed
2: The speed of two separate feed speed
1: slow and fast in speed while feeding
0: speed two-speed feed simultaneously
D1: Weighing complete output mode
1: withdrawal enjoys a door, said output of finished material
0: Delay time to withdraw said the finished material output
3, weighing function 3
F -2 - 3
D4: Automatic trimming range air volume
3:1 / 4
2:2 / 4
1:3 / 4
0:1
D3: whether to allow air volume automatically trimmed
2: Allow the whole process of correction (to trim fast forward air
volume,
In the amount of intake air, slowly into the air volume - temporarily
use)
1: allow normal correction (only trimmed jog air volume)
0: Not allowed
D2: air volume automatically trim the number (1-9)
D1: whether to allow peeled
2: Power Digital peeled and peeled allowed
1: Allow peeled
0: Do not allow peeled
D8 D7 D6 D5 D4 D3 D2 D1
D4 D3 D2 D1
Tangshan automation of balanced

4, continuous (sequence) feeding mode


F -2 - 4
D6: continuous feeding mode whether to allow empty enjoys a door
1: Enable
0: Not allowed
D5: continuous feeding mode Super Bad whether to allow the
discharge under the circumstances set
1: Enable
0: Not allowed
D4: Mode Selection
1: continuous feeding mode
0: Simple Compare Mode
D3: Jog compensation input whether to allow
1: Enable
0: Not allowed
D2: continuous feed to the air volume is just at the beginning of the
end point detection by weight (as determined over
Difference frequency is zero, there is no cumulative weight; does not
compensate the work) ----- determine tolerance times
Set to zero if the number allowed.
1: Enable
0: Not allowed
D1: continuous feed to the start point is detected zero range,
Peeled detection times (peeled cycle) is allowed to set to zero.
1: Enable
0: Not allowed
5, the function keys disabled
F -2 - 5
D4: print key function is valid
1: Effective
0: Invalid
D3: Accumulated View key is valid
1: Effective
0: Invalid
D2: school scale key is valid
1: Effective
0: Invalid
D1: Peel Clear key is valid
1: Effective
0: Invalid
6, the digital filter
Set a filter between 0-250 times: vibration settings according to the
scene
Moving the internal balance the A / D conversion over the data of the
clutter suppressing weight value. Balancing mobile number from 2 to
128 times the norm

Around the selection. The more balanced the number of moves to


increase the display more stable, but talks about the slow response.
The smaller the number the faster the response the contrary, it shows
myself are
Easy to clutter. According to the type of weighing select the most
suitable values.
7, the dynamic testing
In this time, the weight value is changed if the change is greater than
the value range is unstable, then re-evaluated to compare.
F -2 -7
Detection time: 2.0s
Range: 5
Detection time (0.0-9.9) range (0-99)
D6 D5 D4 D3 D2 D1
D4 D3 D2 D1
D4 D3 D2 D1
Tangshan day value
Eight, zero tracking
F -2-8
Detection time: 2S
Range: 05
Detection time (0.0-9.9) range (0-99)
9, the set value lock
F -2 - 9
D3: LOCK1
1: ON
0: OFF
D2: LOCK2
1: ON
0: OFF
D1: LOCK3
1: ON
0: OFF
10.4, setting mode 3
Set Mode 3 is to set the initial value of the calibration setting mode.
For example: take the maximum range is set to 9999.
F Confirm / entry 3 confirm / enter the selection mode 3
Press 2 confirm 0 9 9 9 9 confirm / enter
Weight data (5)
Press TARE / Cancel key exit the setup, complete the operation.
1, school scales password
F-3-1 0000 ~ 9999)
2, the maximum range
F-3-2 00000 ~ 99999
3, the smallest scale

F-3-3 001 ~ 100


4, NW overweight
F-3-4 00000 ~ 99999)
5, the total weight of overweight
F-3-5 00000 ~ 99999
Six, numbers zero range specified value (zero range)
F-3-6 0000 ~ 9999
D4 D3 D2 D1
D3 D2 D1
Tangshan days
7, the function selection
F-3-7
D4: Display refresh rate D1: weight unit
3:25 times / sec 5: N
2:13 times / sec 4: pound
1:6 times / sec 3: kg
0-3 times / sec 2: g
D3: decimal place 1: t
3:3 decimal 0: No
2:2 decimals (Bulk Package 2, small package 3, according to the
resolution may be)
1:1 decimals
0: No
D2: 1/10 scale body resolution display is valid
1: Effective
0: Invalid
8, automatic drop in intake limits specified (should be set to not
automatically fall Amendment)
F-3-8
The range 0-99999 to ban them into stopping time compared to the
weight of the value of the specified limits into the automatic drop
compared, the difference is greater than the value
Can not be used as the basis for correcting.
9, fast forward automatically drop the limits specified (should be set to
not automatically fall Amendment)
F-3-9
Fast forward limits specified automatically fall in the range 0-99999,
when stopping to prohibit fast-forward compared to the weight of the
value and the fast-forward automatically drop
Compared with predetermined limit values, the difference is greater
than this value can not be used as the basis for correcting.
10.6, set the Mode 5
Setup Mode 5 is used for debugging XK3201 (F701B / D) of the display,
keyboard, sensors and input-output detection.
For example: To make input detection settings.

F Confirm / entry 5 confirm / enter the selection mode 5


Press 6 confirm InPUt 0000000000000 confirm / enter
IN1-IN13 valid response indicator is a F1-F13
Press TARE / Cancel key exit the setup, complete the operation.
1, the alternate function: F-5 - 1
Alternate functions.
2, the output selection: F -5 - 2
A total of 4, D4, D3, D2, D1, respectively:
D4: OUT13 output line feature set D1: OUT10 output line feature set
7: Two-Scale Contact 9: Weighing finished
6: Loose bags 8: shoot Bag
D4 D3 D2 D1
D4 D3 D2 D1
Tangshan automation of balanced
5: 7: Ultra Poor
4: Run Output 6: Discharge
3: Near Zero Output 5: folder bag
2: Upper limit output 4: Slow Feed
1: Lower Output 3: Medium Feeding
0: Continuous Weighing weight or error 2: Fast feed
D3: OUT12 output line feature set 1: Cut the Door
7: Two-Scale Contact 0: Feed
6: Loose bags D2: OUT11 output line feature set
5: 9: Weighing finished
4: Run Output 8: shoot Bag
3: near zero output 7: Ultra Poor
2: Upper limit output 6: Discharge
1: Lower Output 5: folder bag
0: Continuous Weighing weight or error 4: Slow Feed
3: the feed
2: Fast feed
1: Cut the Door
0: Feed
When you need more than a few output terminal is used to set
Note: 1, Run Output: When the instrument into the automatic
operation, the output of the operation output is active when the meter
stops working, remove the run
Output.
2, the weight of said material error or continuous output: When the
instrument displays an error symbol (see P45), the error output valid
output, when the instrument display
Showed no error symbol, remove the error output.
3, A / D sampling
F-5-3

AD sample testing, on-screen display to enter this parameter AD


values; used to judge the quality of the sensor signal.
4, the display
F-5-4
Good or bad for the detection instrument display section
5, the keyboard scan detection
F-5-5
Instrumentation keyboard part is good or bad for "0-F"
6, the input detection
F-5-6
Input Detection: IN1-IN12 effective response F4-F16 when the single
display changes from "0" to "1." (See P41)
7, the output detection
F-5-7
Output detection: Type 1-13 valid response OUT1-OUT13 output. (See
P42)
10.7, setting mode 6
Setting mode 6 is about time parameter set mode.
For example: should discharge doors off time is set to 0.5 seconds.
F Confirm / entry 6 confirm / enter the selected setting mode 6
Tangshan
Press 3 confirm 0. 5 confirm / enter
Time parameters (2)
Press TARE / Cancel key exit the setup, complete the operation.
1, the delay time on the material level
F-6 - 1
Feeding on delay time: The setting range is 00 to 99 seconds to
determine when to feed hopper without feeding, feed motor open,
there is expected to determine the feed hopper
When feeding feeding motor delay after delay time stop feeding.
2, the discharge delay closing time
F -6 -2 0.5
Discharge delay closing time: The setting range is 0.0 to 9.9 seconds,
the range of discharge is less than zero, the delay time to shut the
door scales;
3, the discharge gate closing time
F-6-3
Discharge doors off time: The setting range is 0.0 to 9.9 seconds, do
shut the door cylinder scales required action time;
4, automatic peeling time
F-6-4 0.5
Auto Tare Time: The setting range is 0.0 to 9.9 seconds, in the
production process, automatic tare stabilization time is required; when
the discharge door is closed,

Due to mechanical role in said hopper will shake so that the displayed
value is near zero movements, can now automatically peeled time to
ensure that there is sufficient
Of time for the discharge door closed, to improve the stability of zero.
Select 0.0 = no automatic tare time, 0.1 to 9.9 = automatic tare time
is set to 0.1 to 9.9
Seconds in the automatic tare detection times (F1-5) is in effect, first
join this automatic tare time to ensure stability before making peeled
scale body movements, where the sub-feeding
No peeling action, the delay time will be valid peeling.
5, folder bag time
F-6-5
Folder bag Time: The setting range is 0.0 to 9.9 seconds, perform the
action folder bag cylinder needs time;
6, the time delay start shooting bags
F-6-6
Delay start shooting bags Time: The setting range is 0.0 to 9.9
seconds, the time delay after unloading bags of procedures performed
after shooting;
7, the delay time loose bags
F-6-7
Delay loose bags Time: bucket weighing in at a shoot bags after the
door has been sentenced to scale into the closed state, the time delay
loose bags;
In the absence of scale in shot bags bucket after the time delay loose
bags.
8, loose bags output time
F-6 -8
Loose bags Output Time: Set the range of 0.0-9.9 seconds, loose bags
signal output time; 0.00 no loose bags output.
9, shot bags parameters
F-6-9
Clap clap bags bags frequency pulse beat bags inflation time
D3: shoot Bag Views: 00 ~ 99 times, pneumatic shooting bags, the
cylinder stretching times.
D2: shoot bag pulse time: 0.0 to 9.9 seconds, pneumatic shooting
bags, the cylinder telescopic interval.
D1: shoot bags inflation time, 0.0 to 9.9 seconds, a time full stroke
cylinder introduced; (in tons of packaging for this time of 00-99
seconds)
10.9, setting mode 9
7 is the clock setting mode, parameter save and restore, spare palette
settings.
For example: Parameter reset to factory operations.
F Confirm / entry 9 confirm / enter the selection mode 9
0 0 - 0.2 - 0.5

Tangshan days Balance Auto


Press 8 confirm / enter 1 confirm / enter
Select Data (1)
Press TARE / Cancel key exit the setup, complete the operation.
1, the clock setting
F-9 - 1
Clock Set: You can set the year, month, day, hour, minute.
1, print mode settings
F-9 - 2
D4 D3 D2 D1
D4: Printer selection
1: Wide play a
2: Width play 2
3: Narrow playing a
4: Narrow play 2
D3: Print Mode Selection
1: Manual Print
2: Automatic printing; automatic continuous printing
3: Automatic printing; printing at a set time
D2: Print hours setting: 00 to 23
D1: Print minute setting: 00 to 59
8, preservation and restoration parameter tuning parameters
F -9 - 8
Save debug parameters and restore parameters: Optional 1,2,3. 1:
Indicates restore the factory parameters; 2: indicates that the recovery
has been saved debugging parameters (such as
Debug parameters are not saved, then restore the factory with the
same parameters); 3: Save the current parameters have been
debugged; into a good save debugging parameters
Password: 7582, set a password basis having the Enter key, wait 5
seconds saved.
9, alternate board selection
Alternate Board Selection: A total of 3, D3D2D1, showing the
instrument three alternative peripheral devices are installed
F -9 - 9
D3: RS-485 is installed
1: Yes
0: No
D2: D / A converter is installed
1: Yes
0: No
D1: RS-232 is installed
1: Yes
0: No

Note: RS-485 and RS-232 can only select one of the valid (required
before ordering specified).
11, the actual calibration methods
The actual load applied (weight) to the load sensor (scales), the
displayed value is replaced when any indication value (weight by
weight values)
The actual operation is called calibration.
11.1, need to pay attention before calibration
(1), determine the maximum weight value, minimum scale value, and
be set separately.
Within the rated load of the sensor determines the maximum weight
value scale (full scale).
Max weighing minimum scale value becomes the scale of the display
resolution.
--D3 D2 D1
Tangshan days
Press 8 confirm / enter 1 confirm / enter
Select Data (1)
Press TARE / Cancel key exit the setup, complete the operation.
1, the clock setting
F-9 - 1
Clock Set: You can set the year, month, day, hour, minute.
1, print mode settings
F-9 - 2
D4 D3 D2 D1
D4: Printer selection
1: Wide play a
2: Width play 2
3: Narrow playing a
4: Narrow play 2
D3: Print Mode Selection
1: Manual Print
2: Automatic printing; automatic continuous printing
3: Automatic printing; printing at a set time
D2: Print hours setting: 00 to 23
D1: Print minute setting: 00 to 59
8, preservation and restoration parameter tuning parameters
F -9 - 8
Save debug parameters and restore parameters: Optional 1,2,3. 1:
Indicates restore the factory parameters; 2: indicates that the recovery
has been saved debugging parameters (such as
Debug parameters are not saved, then restore the factory with the
same parameters); 3: Save the current parameters have been
debugged; into a good save debugging parameters

Password: 7582, set a password basis having the Enter key, wait 5
seconds saved.
9, alternate board selection
Alternate Board Selection: A total of 3, D3D2D1, showing the
instrument three alternative peripheral devices are installed
F -9 - 9
D3: RS-485 is installed
1: Yes
0: No
D2: D / A converter is installed
1: Yes
0: No
D1: RS-232 is installed
1: Yes
0: No
Note: RS-485 and RS-232 can only select one of the valid (required
before ordering specified).
11, the actual calibration methods
The actual load applied (weight) to the load sensor (scales), the
displayed value is replaced when any indication value (weight by
weight values)
The actual operation is called calibration.
11.1, need to pay attention before calibration
(1), determine the maximum weight value, minimum scale value, and
be set separately.
Within the rated load of the sensor determines the maximum weight
value scale (full scale).
Max weighing minimum scale value becomes the scale of the display
resolution.
--D3 D2 D1
Tangshan days...
The maximum weight value minimum scale value 10000 decisions
within the scope of the value. (Internal resolution of this instrument is
1/40000).
Max weighing 100.00kg 50.00kg 50.000kg 500.00kg
Minimum scale value 0.01kg 0.01kg 0.005kg 0.10kg
Display resolution 1/10000 1/5000 1/10000 1/5000
F Confirm / entry 3 Confirm / Enter Select setting mode 3
Max weighing 2 confirm enter
Minimum scale value 3 confirm enter
(2), the decision unit display: 5: N 4: Ib 3: kg 2: g 1: t 0: No
Function Select 7 confirm enter
(3), and the sensor body in order to ensure a suitable temperature,
switch on the power for 30 minutes.

11.2, the calibration procedure


a, zeroing operation
(1) Check the load sensor (scales) around the periphery confirmed with
and without contact with the machine or foreign, unnecessary load is
not placed
And so on.
F Press OK / ENTER confirmed by school scales / entry
Instrumentation required to enter the password: Press number keys to
enter the password meter "F3-1" setting and press OK / Enter button
after 15 seconds countdown meter
Complete zero adjustment, if only need to press the zero adjustment
peeled / Cancel button to complete the zero adjustment exit.
b, full scale (full scale) Tuning:
After completion of the zero adjustment press the number key "1",
press OK / Enter button to display the instrument under F - CAL-0500.0:
(A) less than the maximum weight value of the weights into a load
sensor (scales) inside. (Max weighing more than 50% of the weight of
its linear
Etc. better)
(2) to be the same as the zero calibration, make sure the load is not
placed unnecessarily.
0500.0 for the school in which the weight scale weight, enter the
current school scale weight weight after the weight placed on the
carrier (hopper) and press the enter / input
Into the key instrument countdown 15 seconds after completion of the
weight adjustment, press TARE / Cancel key to exit calibration is
finished
12, manual printing operation (optional feature)
12.1, enter the manual print operation and display method:
Press F confirm / enter Print confirm / enter
into a variety print selection; Menu screen display:
The blinking digit number for the species, you can choose "0 ~ 9" No.
varieties, so when you press the Print key to print all the content
of all varieties;
So when you select "1" for a variety of press Confirm / Enter]
key; Menu screen display:
Bit is 1, the scintillator varieties "0" bit; indicates total batch No. 1
species; the scintillator bits select the "0 to 3"
"0": Indicates the 1st batch varieties cumulative; "1": Indicates the 1st
class varieties produce cumulative; "2": Indicates the 1st varieties
cumulative total production;
So when you select "2" means print the 1st species cumulative total
production, according to 2 Print confirm / enter] key to
print

No. 1, the cumulative total yield varieties, when the instrument into
the background printing, display returns to normal power-on state.
Note: The above method only in print does not enter automatic mode
printing.
12.2, into the automatic printing methods
In the course of printing, the system will set the parameters within the
instrument performs printing (printing parameters: F-9-2)
13, the cumulative data viewing and removal
13.1, enter the accumulated data view and display method:
Press F confirm / enter the cumulative confirm
/ enter to enter a variety of cumulative selection; Menu screen
display:
The blinking digit number for the species, you can choose "0 ~ 9" No.
varieties, so when you select "1" for a variety of press Confirm
/ Enter] key;
Menu screen display:
Bit is 1, the scintillator varieties "0" bit; indicates total batch No. 1
species; the scintillator bits select the "0 to 3"
"0": Indicates the 1st batch varieties cumulative; "1": Indicates the 1st
class varieties produce cumulative; "2": Indicates the 1st varieties
cumulative total production;
So when you select "2" indicates See the 1st species cumulative total
production by 2 Confirm / Enter] key to view the No. 1 overall
species
Cumulative production, the menu screen display:
13.2, enter the accumulated data removal and display method:
This time as press Confirm / Enter] key, enter the total removal of the
instrument state, the menu screen display:
Enter the total removal of the state, the instrument displays PASSXXXX, enter the correct password (F3-1) is set, enter the clear
cumulative total production
Operation.
Meter clear cumulative total production, the menu screen returns to
display:
Cumulative data purge settings choose 3:00, you can clear the current
batch varieties, middle classes, the cumulative total production.
Then you can re-select the content you want to view or clear, press
Confirm / Enter] key repeat the above operation. To return to the
press
Leather / Cancel] key to return to normal power-on state.
Note: The above method can only be accumulated in clear view and
did not enter the automatic start mode operation.
14, tare
Front panel operation tare

Press the front panel peeled / Cancel button, the display immediately
becomes 0, and "TARE" lights up.
Tare range can range from full or 0 <tare weight value max
choosing.
* Even with tare operation display value does not become zero, may be
caused by the following reasons: Indicates the value is outside the
range of tare.
According to the set requirements (F1-0-D1, F2-3-D1, F3-6) in the press
settings tare tare operation.
15, the digital filter
Moving the internal balance the A / D conversion over the data of the
clutter suppressing weight value. Balancing mobile number from 2 to
128 times a second
Range selection. The more balanced the number of moves to increase
the display more stable, but talks about the slow response. The smaller
the number the faster the response the contrary, it shows myself are
Easy to clutter.
According to the type of weighing select the most suitable values.
Tangshan...
Analog filtering
From the input signal from the load cell to remove the interference
component, but also on the average of the analog signal processing, is
used to stabilize weight
Value of the low-pass filtering rate. From 2Hz, 4Hz, 6Hz, 8Hz four types
of cut-off frequency to choose. Lower cut-off frequency is displayed
more growth
The more stable, but acknowledge it worse. Conversely higher the
frequency response is better, but the show myself are not stable.
17, ultra poor judgment and handling
Ultra-poor judgment on the following parameters:
Tolerance F-0-7 00.050 numeric keys to set the tolerance range
Check the number of ultra-poor tolerance checking F -1-6 times (valid
only for continuous mode), which checks the number of ultra-poor
How many scales inspected once per ultra-poor, usually set to 01
scales are checked every ultra-poor.
Weighing function 1 F -2 - 1 D3: quantitative and (tolerance) a
comparison of whether discrimination tolerance.
1: do not compare
0: Compare
Tolerance is allowed discharge F-2-4 D5: continuous feeding mode
Super Bad whether to allow discharge, that is, whether you want to
receive IN10 (ultra-poor pine Bag input port)
Signal after discharge.
1: Enable
0: Not allowed

Example: F-0-7 tolerance to: 0.050


Check the number of F -1-6 tolerance is set to: 01.
Weighing function 1 F -2 - 1-D3: set to: 0: Compare
Tolerance is allowed discharge F-2-4-D5: set to: 0: Not allowed
After setting the parameters Function: This combination parameter
settings, the final weighing error of 0.050 kg, each said volume to
compare the error, if it is determined that the weighing
Packet times as required to receive IN10 error signal before allowing
discharge or loose bags.
18, automatic drop correction
Automatic drop correction processing was transferred after the weight
value stored in the buffer register and the counter value is
incremented by +1. Then, taking into account the
The value becomes the set number, the average number of times, the
average of the stored data, and the corrected counter value drop to 0.
Access to electricity
Source and changing the difference of the set value, the counter value
becomes 0.
(Example): Quantitative 20.000
Slow automatically fall into the limits specified in F-1-7 0.100
F-2-3 D2: air volume automatically trim the number (1-9) is set to: 4
F-2-3 D3: whether to allow air volume automatic trimming: set to: "1"
to allow normal correction (only slowly into the air volume trim)
F-2-3 D4: Automatic trimming air volume range: set to: "2" 2/4
The number of actual weight value weighing weighing error correction
counter drop drop
0 0 power on
1 1 0.500 20.050 +0.050
2 2 0.500 20.040 +0.040
3 20.070 +0.070 3 0.500
4 20.080 +0.080 4 0 0.500
+0.240 / 4 = 0.060
0.060x2 / 4 = 0.030 correction value calculation
5 20.020 +0.020 1 0.530
6 20.000 0.000 2 0.530
7 20.010 +0.010 3 0.530
8 20.110 (+0.110) x 3 0.530
9 20.010 +0.010 4 0 0.530
0.010x2 / 4 = 0.005 correction calculation value
10 19.880 (-0.120) x 1 0.535
11 19.990 -0.010 1 0.535
12 20.010 +0.010 2 0.535
13 20.000 0.000 3 0.535
14 19.980 0.020 4 0 0.535
Tangshan...

-0.020 / 4 = -0.005
-0.005 X 2/4 = -0.0025
Rounding
-0.003 correction value calculation
19, the output switching operation
Enter "F-5-2", the instrument alternate output function can be selected
for other functions to replace output ports
D4: OUT13 output line feature set D1: OUT10 output line feature set
7: Two-Scale Contact 9: Weighing finished
6: Loose bags 8: shoot Bag
5: 7: Ultra Poor
4: Run 6: Discharge
3: 5: folder bag
2: Upper limit output 4: Slow Feed
1: Lower Output 3: Medium Feeding
0: Continuous Weighing weight or error 2: Fast feed
D3: OUT12 output line feature set 1: Cut the Door
7: Two-Scale Contact 0: Feed
6: Loose bags D2: OUT11 output line feature set
5: 9: Weighing finished
4: Run 8: shoot Bag
3: 7: Ultra Poor
2: Upper limit output 6: Discharge
1: Lower Output 5: folder bag
0: Continuous Weighing weight or error 4: Slow Feed
3: the feed
2: Fast feed
1: Cut the Door
0: Feed
20, input IN port detection
XK3201 (F701B / D) input port of selfInto the instrument input F-5-6 self-test, you must first check the input
port IN1 ~ IN13 and COM and V + is wired correctly. See all
Scale body input wiring table, only the external wiring of the
instrument under the right circumstances can detect the quality of the
instrument input port.
Into the instrument input F-5-6 self-test function
Press F confirmation / entry 5 confirm / enter 6
The menu screen display:
Press Confirm / Enter] key, the menu screen display:
At this time, when the input port IN1 ~ IN13 and COM terminal
Daotong connected, the menu screen display:
Exit input detection by peeled / Cancel] key to return to normal
power-on state.
21, the output OUT port detection
Tangshan...

XK3201 (F701B / D) output port of selfEnter the instrument output F-5-7 POST, you must first check the
output port OUT1 ~ OUT16 and COM is wired correctly. See all scales
Body output wiring table, only the external wiring of the instrument
under the right circumstances can be detected in the quality of the
instrument output port.
Press F confirmation / entry 5 Confirmation / 7
access The menu screen display:
Press Confirm / Enter] key, the menu screen display:
Print available at this time, the cumulative select required
to detect OUT "01 ~ 16" output number, press Confirm / Enter] key,
the menu screen display:
Then press 1 key, OUT1 and COM connected, OUT1 effective
output, press 0 key, OUT1 is disconnected from COM, OUT1 stop
output;
To switch detects another output channel press peeled / Cancel] key,
the menu screen display:
Repeat the above steps can detect any output channel, press
peeled / Cancel] key, then exit the output detector returns to normal
power-on state.
22, A / D conversion data detection
XK3201 (F701B / D) of the A / D analog to digital converter channel
mouth POST
Enter the instrument A / D analog to digital converter channel mouth F5-3 POST, you must first check the output port sensor wiring is correct.
(See P12)
Press F confirmation / entry 5 confirm / enter
3 The menu screen display:
The data for the sensor voltage signal by the analog channel by the A /
D converter into a corresponding number, the number without units,
with the sensor signal
Increases, decreases.
23, over-range display, error display
ADOL (A / D converter overflow)
Sensor signal input over XK3201 (F701B / D) signal range.
No. Error alarm false alarm Meaning
1 ADOL A / D converter overflow
2 ADNO A / D converter negative overflow
3 Error1 current value> value range +9 points
4 Error2 started simultaneously with effective suspension
5 Error3 started simultaneously with effective emergency
6 Error4 Enter the weight value exceeds the maximum range
7 Error5 enter weight value of "0"

8 Error6 scale sequence settings: Maximum span> Target> PCWORD


value> slowly into the value of> air volume
9 Error7 write E2rom wrong
10 Error8 read E2rom wrong
11 Error9 write clock error
12 Error10 read clock error
Tangshan...
Make sure that the load does not exceed 20mV output voltage or
XK3201 (F701B / D) and the load cell cable is connected or
disconnected
Load sensor cable for errors. Also a load sensor on the rear panel
connector is not connected to any device, the display will appear
Shown.
ADNO (A / D converter negative overflow)
Sensor signal input below XK3201 (F701B / D) the minimum input
signal range.
Make sure that the load sensor output voltage is lower than 0mV or
XK3201 (F701B / D) and the load sensor connection cable is broken
Line. Also a load sensor on the rear panel connector is not connected
to any device, the display will appear.
Error1 (GW> Max weighing +9 scale value)
Gross value exceeds the maximum weight value +9 scale value. The
over-range display should return to normal weight display when the
load sensor
Input signal drops to over-range display disappears.
Error2 (timing errors)
Weighing the start signal is ON, the stop signal goes ON.
Please stop signal is set to OFF, the start signal is input again begin
weighing.
(Timing errors)
The weighing is set to ON when the start signal, emergency stop signal
becomes ON.
Please stop signal is set to OFF, the start signal is input again begin
weighing.
Error4 (calibration error)
Weight calibration weight value or interval value is set to be larger
than the maximum weight value. Please re-set weight weight value or
the maximum value and once again called into
Line spacing calibration.
Max weighing and weight Weight value of the relationship
Load
+9 Scale value
Maximum weight value
Weight weight value
50%

If you want to be spaced properly calibrated, the value at the


maximum recommended weight weight weight value of 50% to a
maximum weight value between the calibration.
Error5 (calibration error)
Eliminate the initial amount in the negative tare (-) side. Make sure
that the load is applied to the load cell or load cell on the right
direction of + SIG
And-SIG's wires are reversed.
Error6 (setting error)
When XK3201 (F701B / D) can not meet the preset parameters
(maximum range> Target> PCWORD value> slowly into the value of>
air volume) when.
Please preset parameters satisfy the condition, eliminating errors.
24, the use of shortcut keys
The instrument features 10 shortcut keys, operation and function are
described below;
(A) The role of shortcut keys: You can directly modify the shortcut keys
corresponding to the parameters, without entering a password or
instrument downtime
Setting.
(B) the use of shortcuts: for example modified (increased from 25.00
kg to 30 kg)
(A) directly press "9" under the instrument screen displays "F-0-9025.00".
(2) Press Confirm / Enter] key changes directly enter the required data,
quantitative value to "F-0-9-030.00"
(3) Press Confirm / Enter] key to save the settings, press peeled /
Cancel] key to exit the settings.
Meaning shortcut menu display format (for example to two decimal
places)
0 Variety No. F-0-0-X
1 upper limit F-0-1-XXX.XX
Lower limit value F-0-2-XXX.XX
Tangshan
3 Zero range F-0-3-XXX.XX
4, into the amount of F-0-4-XXX.XX
5 jog volume F-0-5-XXX.XX
6 advance the amount of F-0-6-XXX.XX
7 tolerance F-0-7-XXX.XX
8 Flow control value F-0-8-XXXXXXX
9 quantitative value of F-0-9-XXX.XX
25 scale body model with bucket packing scale 1 ------ timing control
process and manner
25.1, XK3201-F701B / D Meter has bucket packaging scales workflow
table (to 25.00kg for example)

Numbered sequentially by job


No. Process Name parameter position input port output port
Show
Attach
Judgment process
Instrument is powered up, initialization AD, the AD for zero calibration;
displays scan, sentenced the boot is cleared. Column shows the weight
on the lower bar shows: species number, scale body type:
PPON-0-1; sentenced clip loose bag program. Press " " key to
display the next screen species number, the actual target amount,
duty batch accumulated error value, flow value, cumulative output
And so on.
A sentence starts after power is receiving the letter
Number
IN1
2 start (start mode selection) F2-2-D7 U
Three species transferred when the second set parameters F0-0
4 sentenced to weighing mode;
1: bucket packaging scales.
F2-1-D4
5 sentenced the need empty enjoys doors F2-4-D6
6 sub-folder bag is clamped Mark K
7 scales doors open output OUT7
Eight sub-scales doors are shut in place IN6 b
9 sentenced peeled cycle F1-5
10 sentenced automatic tare range F3-6
11 Time delay automatic tare F6-4
12 peeled A
Sentenced clip loose bags and bags of emergency:
Judge whether there is folder bag request (IN7);
Show: J
Output folder bag signal (OUT6);
Time delay folder bag (F6-5);
Sentenced folder bag in place (IN8); Show: K
Home folder bag in place marker;
Judge whether there is folder bag request (IN7);
Withdrawal output folder bag signal (OUT6);
Withdraw folder bag in place marker;
Loose bags signal output (OUT13 choose 6);
Loose bags output time delay (F6-8) retreat
Loose bags output.
13 judgment on whether there is material level hopper feed;
No material shortage subroutine is started
IN4 C
14 entered the feed gate OUT2 D
15 feed gate is opened in place; IN5 E

16 contracting feed mode is selected; F2-2-D2


Lack of material subroutine
Judgment on the material level is valid (IN4)
On feeding motor action (OUT1)
Judgment on the material level is valid (IN4)
Sentenced to closing time delay on the feed (F6-1)
Feeding on the motor stops (OUT1)
17 start fast, medium and slow output OUT3, OUT4,
OUT5
18 sentenced to whether the amount of fast-forward to; F0-9-F0-4
19 stop fast forward; OUT3
20 prohibit comparative delay time; F1-1 F
21 sentenced feeding points speed selection; F2-2-D2
22 to enter into the judgment of whether the amount of feed to the F09-F0-5
23 stop in progress; OUT4
24 prohibit comparative delay time - F1-1 G
25 into a jog to judge whether the amount of slow forward F0-9-F0-6
26 stop jog OUT5
27 closing hopper OUT2
28
Sentenced to compare the number of detections ----- not detect
Skip directly to the ultimate reality show
Target weight
F1-6
29 air volume stability judgment time; F1-2 H
30 sentenced to dynamically detect the stability of the F2-7
31 sentenced slowly into the air amount correction value method F3
32 sentenced error F0-7
33
Sentenced to append mode, the error is less than the set
Target amount allowable negative error for
c
Said the finished material bags loose bags after shooting procedures:
Judge whether there started shooting bags labeled
Shot output time delay bags (F6-6-D1)
Beat signal output Bag (OUT9)
Delay beat inflation time (F6-6-D2)
Undo bags beat signal output (OUT9)
Judge whether there beat frequency (F6-6-D4)
(No jumps to the end of the racket bags)
Time delay beat amplitude (F6-6-D3)
Beat signal output Bag (OUT9)
Time delay beat amplitude (F6-6-D3)
Repeat sub beat frequency (F6-6-D4)
The end of the shoot Bag (OUT9)

Set the end of the shoot Bag tag


Song Bag Procedure:
Judge whether the end of the shoot bags
Judge whether the output of said door is closed
Loose bags delay time (F6-0)
Tangshan...
Jog added compensation until less than allowed
Slight error;
34 sentenced error (difference signal output Ultra) F0-7 o
35 shows the final actual target weight; said
After the amount of signal output
OUT9
Undo folder bag output (OUT6)
Loose bags signal output (OUT13 choose 6)
Loose bags output time delay (F1-2) evacuation
Loose bags Output
36 sentenced said the finished material output mode F2-2-D1 delay
(F1-1) signal withdrawal said the finished material
37 The total value added, total duty preset
Number of packages
L sentenced to transmit communications;
38 sub-folder bag J
39 ultra-poor judgment whether to allow the discharge F2-4-D5
40 ultra-poor judgment whether to allow the discharge signal IN10
Discharge gate 41 outputs enjoys OUT7
42 home starts shooting bags labeled
43 sub-zero range comparison mode F2-1-D1
44 sub-zero range
45 sub-scales doors off delay time F6-2
46 Off scales doors OUT7
47 sub-scales gate delay shut off gate time scales
48 Back to 8
49 sentenced to whether there lockout tag
50 P sentenced emergency shutdown
25.2, XK3201-F701B / D Meter has bucket packaging scales workflow
parameter table
User parameter set default parameters default user parameters set
parameters
F0 Mode 0: preset parameters F4 Mode 4: Optional Parameters
F-0-1 cap 50000 Invalid F-4-1 D / A output mode 3
F-0-2 00000 Invalid lower F-4-2 D / A Zero Weight 0.00
F-0-3 near zero 0.5 F-4-3 D / A full-scale value 25.00
F-0-4 in the feed amount of 10.00 F-4-4 D / A spacing adjustment 8004000
F-0-5 volume slowly into 5.00 F-4-5 ID No. 01

F-0-6 air volume 0.3 F-4-6 RS-232, RS-485


Mode setting
31011
F-0-7 tolerance 0.05 F-4-7 external function selection 1120
F-0-8 flow value 0000000 Invalid F5 Mode 5: Instrument Self Test
F-0-9 target amount 25.00 F-5-1 alternate function 00 is invalid
F-0-0 breed No. 0 F-5-2 output selection 6498
F1 Mode 1: operating parameters F-5-3 A / D sampling
F-1-1 Comparison Inhibit Time 0.8 F-5-4 display test
F-1-2 air volume down given time 0.8 F-5-5 keyboard detection
F-1-3 Weighing completion signal
Output time
1.0 F-5-6 input detection
F-1-4 Jog Time 0.0 F-5-7 output detection
F-1-5 peeled cycles 01 F-5-8
F-1-6-tolerance Analyzing frequency 01 F-5-9
F-1-7 Slow automatically fall into
Specified limits
1.00 F-5-0
F-1-8 analog filter 2 F6 Mode 6: Time Parameter
F-1-9 permitted weight of the container
Error
00 (%) invalid F-6-1 feed on delay time
Between
50
F-1-0 Tare function 00 F-6-2 discharge delay closing time 1.0
F2 Mode 2: Run mode F-6-3 discharge door is closed
Between
0.5
F-2-1 weighing function 1 01010 F-6-4 automatic tare Time 2.0
F-2-2 weighing function 2 00011101 F-6-5 clip bag Time 0.3
F-2-3 weighing function 3 0011 F-6-6 delay start shooting bags
Time
0.5
F-2-4 successive (serial)
Mode
111000 F-6-7 loose bags delay time 0.5
F-2-5 function keys ban 1110 F-6-8 loose bags Output Time 0.0
Tangshan
F-2-6 digital filter frequency 32 F-6-9 shooting bags parameters
F-2-7 Dynamic Detection 0.5-02 F7 Mode 7: Supplementary parameters
F-2-8 zero tracking 0.5-02 F-7-1 feed bag shot
Start Weight
0.00 Invalid
F-2-9 setpoint LOCK 011 F-7-2 in the feed end of the bag shot

Weight
0.00 Invalid
F3 Mode 3: school scale parameter F-7-3 Preset Batch 0000
F-3-1 school scales password 1234 F-7-4 times 00 loose bags
F-3-2 maximum range 99.99
F-3-3 smallest scale 001 F-7-6 Flow Hits 00
F-3-4 NW overweight 99.99 invalid F9 Mode 9: Special Parameters
F-3-5 99.99 total weight overweight invalid F-9-1 clock settings
F-3-6 digit zero range
Specified value (zero
Range)
2.50 F-9-2 print mode setting 1-1-00-00
F-3-7 function select 13203 F-9-8 save debugging parameters
And restore parameters
F-3-8 into the automatic drop in
Specified limits
5.00 invalid F-9-9 board selected when ordering spare optional)
F-3-9 Fast Forward Automatic Free Fall
Specified limits
8.00 Invalid
25.3, there fighting packing scale input port selection table
External signal input signal, the input circuitry separated by the optical
coupler.
Pin terminals
Name
Pin Meaning Function Description
IN1 startup / shutdown
This input signal with F2-2-D7 related to the setting, when the F2-2-D7
is set to 0, this input pulse input -IN1 port level transient from high level to low level, the work program
will run automatically; When F2-2-D7 settings
Is 1, this input level input - IN1 port level is low (the common terminal
communicating state), the working
The program will run automatically. IN1 port level is high (and the
common terminal disconnected state), the current one working cycle
Loop controller stopped working after the end of the state, the program
enters manual mode.
IN2 downtime
This input signal only when the F F2-2-D7 is set to 0 is valid, IN2 port
level transient from high to low
Normally, the current one working cycle controller stopped working
after the end of the state, the program enters manual mode.
IN3 stop
When this input is low, the work went into emergency shutdown
procedures. Emergency stop when the first closed fast, medium and
slow feed input

Exports, waiting to exit automatically after allowing discharge status.


IN4 digital signal feeding this input signal is active low. (No, COM
terminal should be shorted)
IN5 input material cutting doors open place
Signal
When this input is low, the controller is allowed to start fast, medium
and slow feed. (No, COM terminal should be
Shorted)
IN6 input discharge door closed in place
Signal
In automatic, when this input is low, the controller is recognized as
scales doors have been closed in place, this time allowing peeled
Or feed. (No, COM terminal should be shorted)
IN7 folder bag request input signal
When this input is active low pulse, folder bag request input signal is
active. Controller output signal folder bag
OUT6.
IN8 input folder bag in place
This input signal with F2-2-D6-related settings, when the F2-2-D6 is set
to 0, IN8 the mouth, such as low
Controllers folder bag in place recognized as valid (unused, COM
terminal should be shorted); When F2-2-D6 is set to 1,
IN8 mouth, such as the high level controller is recognized as an
effective folder bag in place; when F2-2-D6 is set to 2:00, IN8 mouth
like
Is high then the controller is recognized as valid folder bag in place.
IN9 empty
IN10 ultra-poor pine Bag input port
When weighing the actual target times exceeds F0-7 set tolerance, the
controller will not discharge, need to get IN10
Mouth (is low) and the common terminal is turned on, before allowing
discharge. (No, COM terminal should be shorted)
IN11 spare a
IN12 external peeled when F4-7-D2 is set to 1, the input port is active
low peeled.
IN13 empty
V + External DC +24 V power supply, 2 ~ 5A current (with external
DC24V + power connection)
COM1 input common (with external DC24V-connection)
Tangshan...
25.4, there fighting packing scale output port selection table (standby
control signal output when ordering optional)
30.4.1, the output control signal connectors, internal relays for small
passive contact.
Pin end

Subnamespaces
Pin Meaning Function Description
Feeding on the output port OUT1
(Optional)
In automatic operation, the controller sentenced to no material on
material level signal, this points to the common terminal is turned on.
And sentenced to a material on the material level
Signal, the delay F6-1 feeding time and common disconnected.
Cut material gate output port OUT2
(Optional)
When sentenced to a material on the material level signal and allows
the feed, this points to the common terminal is turned on.
Fast feed output port OUT3 sentenced to cut material when doors open
position IN6 input signal is valid, this points to the common terminal
turned into fast-forward.
OUT4 the feed output port
(Optional)
When the controller sentence to the end of the fast-forward amount
(target amount - the amount of feed), this points to the common
terminal conduction into the inlet.
OUT5 slow feed output when the controller is sentenced to the end of
the intake amount (target amount - the amount of slow forward), this
points to the common terminal turned into a jog.
OUT6 folder bag when the controller output folder bag request IN7
signal obtained after this point and the common terminal conduction,
perform folder bag.
When the scale again to IN7 received signal, loose bags perform
emergency procedures. (Applicable to single-head solenoid valves)
OUT7 discharge outlet when the controller said material is completed,
the received signal IN8 folder bag in place, this points to the common
terminal conduction, enjoys a door into the discharge state.
OUT8 ultra-poor material output port when the controller said after the
sentence to more than tolerance, this points to the common terminal
conduction, enjoys the door after discharge, this points to the common
terminal
Disconnected.
OUT9 racket bags outlet when the controller said material shot bags,
this points to the common terminal is turned on. After this point and
shoot bags common terminal is disconnected.
OUT10 spare a usage see output switching operation * P38 *
OUT11 use alternate 2 See output switching operation * P38 *
OUT12 spare 3 (Optional) Use method please refer to the output
switching operation * P38 *
4 Use alternate method OUT13 output switching operations, see * P38
*
COM2 output common

29.4.2, XK3201 (F701D) standby control signal output (when ordering


optional)
Standby output control signal connectors, internal relays for small
passive contacts.
Pin end
Subnamespaces
Pin Function Descriptions Pin Terminal name meaning
Pin Included
Righteousness
Functional Description
OUT14 OUT20 Empty Empty
Empty empty OUT21 OUT15
OUT16 OUT22 Empty Empty
OUT17 OUT23 Empty Empty
Empty empty OUT24 OUT18
OUT19 OUT25 Empty Empty
COM3 output common
25.5, there fighting packing scale operation status prompt
No. Description No. graphic character graphic character description
1 U started, the instrument waits for normal operation 11 H air volume
stability judgment time
2 t wait to enter the shutdown state 12 h steady state judge
3 O enters shutdown mode 13 o determine tolerance
4 A peeled state 14 c are added compensation
5 b Wait 15 L scale door closed position, said material discharge end of
the waiting state
6 C Wait material level there is expected to state 16 K folder bag in
place waiting for the signal
7 d open cut material valve status 17 J Wait folder bag request signal
8 E Wait valve opening cut material in place 18 P did not enter the
running state
9 F Fast forward prohibit comparative waiting time
10 G waiting time into the comparator is disabled
Tangshan...
26 scale body mode 2 ------ No bucket packing scale and method of
timing control process
26.1, XK3201-F701B / D instrument no bucket packaging scales
workflow table
Numbered sequentially by job
No. Process Name parameter position input port output port
Show
Attach
Judgment process

Instrument is powered up, initialization AD, the AD for zero calibration;


displays scan, sentenced the boot is cleared. Column shows the weight
on the lower bar shows: species number, scale body type
Type: PPON-0-2; sentenced clip loose bag program. Press " " key to
display the next screen species number, the actual target amount,
duty batch accumulated error value, flow value, yield
Accumulated other content.
A sentence is receiving start after boot
Signal
IN1
2 start (start mode selection) F2-2-D7 U
Three species transferred when the second set parameters F0-0
4 sentenced to weighing mode;
2: No bucket packaging scales.
F2-1-D4
5 sub-folder bag is clamped Mark K
6 sentenced peeled cycle F1-5
7 sentenced automatic tare range F3-6
8 skinless A
9
Judgment on whether there is material level hopper
Material; no material shortage subroutine is started
Sequence
IN4 C
Sentenced clip loose bags and bags of emergency:
Judge whether there is folder bag request (IN7); Show
J;
Output folder bag signal (OUT6);
Time delay folder bag (F6-5);
Sentenced folder bag in place (IN8); Show K;
Home folder bag in place marker;
Judge whether there is folder bag request (IN7);
Withdrawal output folder bag signal (OUT6);
Withdraw folder bag in place marker;
Loose bags signal output (OUT13 choose 6);
Loose bags output time delay (F6-8) retreat
Loose bags output.
10 entered the feed gate OUT2 D
11 feed gate is opened in place; IN5 E
12 contracting feed mode is selected; F2-2-D2
13 start fast, medium and slow output OUT3, OUT4,
OUT5
14 sentenced to whether the amount of fast-forward to; F0-9-F0-4
15 stop fast forward; OUT3
Lack of material subroutine
Judgment on the material level is valid (IN4)

On feeding motor action (OUT1)


Judgment on the material level is valid (IN4)
Sentenced to closing time delay on the feed (F6-1)
Feeding on the motor stops (OUT1)
16 prohibit comparative delay time; F1-1 F
17 points sentenced feeding speed selection; F2-2-D2
Sentenced to beat bags starting weight (F7-1), sub-shot bags
End Weight (F7-2) and marking
18 stop in progress; OUT4
19 prohibit comparative delay time F1-1 G
20 stop feeding program OUT9 shot bags
21 into a jog to judge whether the amount of slow forward F0-9-F0-6
22 stop jog OUT5
23 closing hopper OUT2
24
Sentenced to compare the number of detections ----- disorderly
Skip directly measured ultimate display
International target weight
F1-6
25 air volume stability judgment time; F1-2 H
26 sentenced to dynamically detect the stability of the F2-7
27 sentenced slowly into the air amount correction value of the square
Law
F3
28 sentenced error F0-7
29
Sentenced to append mode, the error is less than the set
Given target amount allowable negative error,
Jog add compensation until
Less than the allowable error;
c
30 sentenced error (difference signal output Ultra) F0-7 o
31 shows the final actual target weight;
Weighed signal output
OUT11 Select 8
When feeding fluff Bag Procedure:
Weight is to start shooting bags (F7-1)
Beat signal output Bag (OUT9)
Delay beat inflation time (F6-7)
Undo bags beat signal output (OUT9)
Judge whether there beat frequency (F6-9)
(No jumps to the end of the racket bags)
Time delay beat amplitude (F6-8)
Beat signal output Bag (OUT9)
Time delay beat amplitude (F6-8)
Repeat beat

Judge whether to stop shooting bags Weight (F7-2);


Judge whether to stop the intake (OUT4)
The end of the shoot Bag (OUT9)
32 sentenced said the finished material output mode F2-2-D1 delay
(F1-1) signal withdrawal said the finished material
33 Join the cumulative value, taking into account the pre-shift
Set the number of packages
L sentenced to transmit communications;
34 ultra-poor judgment whether to allow the discharge F2-4-D5 IN10 o
35 withdrawal of the output signal OUT8 OUT8 tolerance
36 shot output time delay bags F6-6
37 output signal OUT9 beat bags
38 Delay beat inflation time F6-9-D1
Tangshan...
39 Undo the output signal shot bags
40 judge whether there beat frequency F6-9-D3
41 beat amplitude delay time F6-9-D2
Beat frequency sub repeated 42 F6-9-D3
43 end of the racket bags OUT9
44 bags of loose delay time F6-7
45 Undo folder bag output OUT6
46 output signal OUT13 select six loose bags
47 output time delay loose bags F1-2
48 loose bags withdrawal output OUT13 select 6
49 Back to 5
50 sentenced to whether there lockout tag
51 sentenced emergency shutdown

26.2, XK3201-F701B / D instrument no bucket packaging scales


workflow parameter table
User parameter set default parameters default user parameters set
parameters
F0 Mode 0: preset parameters F4 Mode 4: Optional Parameters
F-0-1 cap 50000 Invalid F-4-1 D / A output mode 0
F-0-2 00000 Invalid lower F-4-2 D / A Zero Weight 0.00
F-0-3 near zero 0.5 F-4-3 D / A full-scale value 999.99
F-0-4 in the feed amount of 10.00 F-4-4 D / A spacing adjustment 0000
F-0-5 volume slowly into 5.00 F-4-5 ID No. 01
F-0-6 air volume 0.3 F-4-6 RS-232, RS-485
Mode setting
31011
F-0-7 tolerance 0.05 F-4-7 external function selection 1120
F-0-8 flow value 0000000 Invalid F5 Mode 5: Instrument Self Test
F-0-9 target amount 25.00 F-5-1 alternate function 00 is invalid
F-0-0 breed No. 0 F-5-2 output selection 6498
F1 Mode 1: operating parameters F-5-3 A / D sampling
F-1-1 Comparison Inhibit Time 0.8 F-5-4 display test
F-1-2 air volume down given time 0.8 F-5-5 keyboard detection
F-1-3 Weighing completion signal
Output time
1.0 F-5-6 input detection
F-1-4 Jog Time 0.0 F-5-7 output detection
F-1-5 peeled cycles 01 F-5-8
F-1-6-tolerance Analyzing frequency 01 F-5-9
F-1-7 Slow automatically fall into
Specified limits
1.00 F-5-0
F-1-8 analog filter 2 F6 Mode 6: Time Parameter
F-1-9 permitted weight of the container
Error
00 (%) invalid F-6-1 feed on delay time
Between
5.0
F-1-0 Tare function 00 F-6-2 discharge delay closing time 1.0 Invalid
F2 Mode 2: Run mode F-6-3 discharge door is closed
Between
0.5 Invalid
F-2-1 weighing function 1 02010 F-6-4 automatic tare Time 2.0
F-2-2 weighing function 2 00011101 F-6-5 clip bag Time 0.3
F-2-3 weighing function 3 0011 F-6-6 delay start shooting bags
Time
0.5

F-2-4 successive (serial)


Mode
111000 F-6-7 loose bags delay time 0.5
F-2-5 function keys ban 1110 F-6-8 loose bags Output Time 0.0
F-2-6 digital filter frequency 32 F-6-9 shooting bags parameters
F-2-7 Dynamic Detection 0.5-02 F7 Mode 7: Supplementary parameters
F-2-8 zero tracking 0.5-02 F-7-1 feed bag shot
Start Weight
0.00
F-2-9 setting LOCK 011 F-7-2 in the feed shoot bags
End Weight
0.00
F3 Mode 3: school scale parameter F-7-3 Preset Batch 0000
F-3-1 school scales password 1234 F9 Mode 9: Special Parameters
Tangshan
F-3-2 maximum range 99.99 F-9-1 clock settings
F-3-3 smallest scale 001 F-9-2 print mode setting 1-1-00 00
F-3-4 NW overweight 99.99 invalid F-9-8 save debugging parameters
And restore parameters
F-3-5 99.99 total weight overweight invalid F-9-9 backup board options
(order-matching)
F-3-6 digit zero range
Specified value (zero
Range)
2.50
F-3-7 function select 13203
F-3-8 into the automatic drop in

Specified limits

5.00
F-3-9 Fast Forward Automatic Free Fall
Specified limits
8.00 Invalid
26.3, no bucket packing scale input port selection table
External signal input signal, the input circuitry separated by the optical
coupler.
Pin terminals
Name
Pin Meaning Function Description
IN1 startup / shutdown
This input signal with F2-2-D7 related to the setting, when the F2-2-D7
is set to 0, this input pulse input -IN1 port level transient from high level to low level, the work program
will run automatically; When F2-2-D7 settings
Is 1, this input level input - IN1 port level is low (the common terminal
communicating state), the working
The program will run automatically. IN1 port level is high (and the
common terminal disconnected state), the current one working cycle
Loop controller stopped working after the end of the state, the program
enters manual mode.
IN2 downtime
This input signal only when the F F2-2-D7 is set to 0 is valid, IN2 port
level transient from high to low
Normally, the current one working cycle controller stopped working
after the end of the state, the program enters manual mode.
IN3 stop
When this input is low, the work went into emergency shutdown
procedures. Emergency stop when the first closed fast, medium and
slow feed input
Exports, waiting to exit automatically after allowing discharge status.
IN4 digital signal feeding this input signal is active low. (No, COM
terminal should be shorted)
IN5 input material cutting doors open place
Signal
When this input is low, the controller is allowed to start fast, medium
and slow feed. (No, COM terminal should be
Shorted)
IN6 empty
IN7 folder bag request input signal
When this input is active low pulse, folder bag request input signal is
active. Controller output signal folder bag
OUT6.
IN8 input folder bag in place
This input signal with F2-2-D6-related settings, when the F2-2-D6 is set
to 0, IN8 the mouth, such as low

Controllers folder bag in place recognized as valid (unused, COM


terminal should be shorted); When F2-2-D6 is set to 1,
IN8 mouth, such as the high level controller is recognized as an
effective folder bag in place; when F2-2-D6 is set to 2:00, IN8 mouth
like
Is high then the controller is recognized as valid folder bag in place.
IN9 empty
IN10 ultra-poor pine Bag input port
When weighing the actual target times exceeds F0-7 set tolerance, the
controller will not discharge, need to get IN10
Mouth (is low) and the common terminal is turned on, before allowing
discharge. (No, COM terminal should be shorted)
IN11 spare a
IN12 external peeled when F4-7-D2 is set to 1, the input port is active
low peeled.
IN13 empty
V + External DC +24 V power supply, 2 ~ 5A current (with external
DC24V + power connection)
COM1 input common (with external DC24V-connection)
Tangshan...
26.4, no bucket packing scale output port selection table (standby
control signal output when ordering optional)
30.4.1, the output control signal connectors, internal relays for small
passive contact.
Pin end
Subnamespaces
Pin Meaning Function Description
Feeding on the output port OUT1
(Optional)
In automatic operation, the controller sentenced to no material on
material level signal, this points to the common terminal is turned on.
And sentenced to a material on the material level
Signal, the delay F6-1 feeding time and common disconnected.
Cut material gate output port OUT2
(Optional)
When sentenced to a material on the material level signal and allows
the feed, this points to the common terminal is turned on.
Fast feed output port OUT3 sentenced to cut material when doors open
position IN6 input signal is valid, this points to the common terminal
turned into fast-forward.
OUT4 the feed output port
(Optional)
When the controller sentence to the end of the fast-forward amount
(target amount - the amount of feed), this points to the common
terminal conduction into the inlet.

OUT5 slow feed output when the controller is sentenced to the end of
the intake amount (target amount - the amount of slow forward), this
points to the common terminal turned into a jog.
OUT6 folder bag when the controller output folder bag request IN7
signal obtained after this point and the common terminal conduction,
perform folder bag.
When the scale again to IN7 received signal, loose bags perform
emergency procedures. (Applicable to single-head solenoid valves)
OUT7 empty
OUT8 ultra-poor material output port when the controller said after the
sentence to more than tolerance, this points to the common terminal
conduction, enjoys the door after discharge, this points to the common
terminal
Disconnected.
OUT9 racket bags outlet when the controller said material shot bags,
this points to the common terminal is turned on. After this point and
shoot bags common terminal is disconnected.
OUT10 spare a usage see output switching operation * P38 *
OUT11 use alternate 2 See output switching operation * P38 *
OUT12 spare 3 (Optional) Use method please refer to the output
switching operation * P38 *
4 Use alternate method OUT13 output switching operations, see * P38
*
COM2 output common
30.4.2, XK3201 (F701D) standby control signal output (when ordering
optional)
Standby output control signal connectors, internal relays for small
passive contacts.
Pin end
Subnamespaces
Pin Function Descriptions Pin Terminal name meaning
Pin Included
Righteousness
Functional Description
OUT14 OUT20 Empty Empty
Empty empty OUT21 OUT15
OUT16 OUT22 Empty Empty
OUT17 OUT23 Empty Empty
Empty empty OUT24 OUT18
OUT19 OUT25 Empty Empty
COM3 output common
26.5, no bucket packing scale operation status prompt
No. Description No. graphic character graphic character description
1 U starts the meter to normal operation 11 h wait determine the
steady state
2 t judge enters shutdown mode 12 o Tolerance

3 O enter the shutdown state is compensated add 13 c


4 A peeled state 14 L said material discharge end of the wait state
5 C Wait material level there is expected to state 15 K folder bag in
place waiting for the signal
6 d open cut material valve status 16 J Wait folder bag request signal
7 E Wait valve opening cut material in place 17 P did not enter the
running state
Fast forward 8 F wait time prohibited compare
9 G waiting time into the comparator is disabled
10 H waiting for air volume stability judgment time
Tangshan...
27 Frequently Asked Questions and handling
Symptom Cause Remedy
Discharge door switch
Abnormal
1, the zero range is set too high
2, the material relatively sticky, slow discharge
1, set the correct zero range, try to lower than 1 kg
2, to extend the F6-2 delay closing time for unloading
Set parameters without
France saved
1, the flash EEPROM damage
2, set the parameters when pressed the Enter key to save
3, set the state power without exiting
1, the replacement of flash EEPROM
2, set the parameters, press the Enter key to save
3, parameter settings after exiting the parameter setting state
No boot
Show
1, a power failure
2, instrument failure
1, check the 220V power line is connected properly, and check the fuse
Is blown;
2, the instrument within the power board or motherboard is faulty and
should be repaired or
Exchange
Show "ADoL"
Or "ADNo"
1, the sensor wiring error or connection failure
2, the sensor is damaged
1, check the wiring and correct
2, the sensor installation problem or damaged and need replacing
Keyboard failure 1, parameter lock
2, the key damage
An unlock method: Refer to F2-9 set.

2, repair or replace the keyboard


Poor dynamic accuracy
1, the connection is not good
2, static accuracy difference
3, the material does not meet the requirements of the state
4, no action or slow-slow feeding feeding time is too short
5, the air volume is set incorrectly
6, the sensor is damaged
7, the air pressure on the load-bearing body
1, appropriate to relax the soft connection part
2, re-calibration scales
3, check the material conditions, does not allow fast knot, moisture
content is too high or twining
Impurities
4, increase the slow feeding quantity setting
5, the material exceeds a set value, should increase the air volume
setting value, and vice versa to reduce
6, the repair or replacement
7, the lifting of the air pressure on the load-bearing body
After the ultra-poor can not
Discharge
Not to the signal input IN10 IN10 input port and COM port shorted.
Parameter setting error can not be started
Need to set the correct parameters:
Parameters required to meet the "maximum range> target volume>
PCWORD amount> slow forward rate> empty
In the amount of "relationship
Work suddenly
Down, down menu
F5 bright screen
1, the door did not open cut material
2, the cut material door is opened, but IN6 input signal line
Disconnect
1, check whether there is a gate signal cut material and whether there
is gas pressure;
2, check the lines and restore the line to normal.
No communication 1, communication line failure connection
2, the communication parameters set incorrectly
1, check the communication line connection is working to ensure that
no circuit, and
TXD and RXD cross-connect
2, check the parameter settings, see RS232/RS485 parameter setting
method
Flow Balance End
After the hold material
1, flow control value is set too

2, the flow control unit is not clear


3, cutting bit signal, wait for the next release after silo
Before discharge
1, check and set the flow control values to meet process requirements
2, set to meet the requirements of the control value (in kilograms)
3, check the material level is normal, the error signal or wait exclude
material discharged.
Discharge is not clean
More than expected
Zero Zero range setting range is set too large decreases
Tangshan days...
Appendix 2
Instrument failure analysis
One, no sensor signal (lower display ADOL or ADNO)
A: Check the sensor wiring is correct;
B: Replace the sensor.
Second, overload (on display Error1)
A: weight bearing on the> maximum range; set a reasonable
maximum range;
B: recalibrated scales.
Four weight data flip
A: Re-calibration scales;
B: Check that the sensor is intact, the wiring is correct;
C: Check whether the carrier collide with the outside world.
Five, school scale, you can not enter the school scale weight back to
the original settings
A: Input school weighing> maximum range, correct setting school
scale weight should be <maximum range.
Six, you can not start (boot)
A: Parameter setting unreasonable, should meet: Maximum span>
target volume (PCWORD amount) advance the amount of the
amount of slow progress;
B: Target volume setting is too large, the target volume <maximum
range, set the appropriate target amount;
C: Check whether the inputs IN1 and COM terminal start signal has
been provided;
D: instrument display weight is greater than zero range, "RTSO Z." on
the LED is not lit,
Instrument can not be zero. Handling exceptions tare;
E: In filling scales, the instrument used to set within the container and
container weight range (container weight, container tolerance) is
inconsistent, resulting in not
Zero into the automatic weighing.
Seven, after weighing not discharge

A: No folder bag request, folder bag-position signal. Check IN7, IN8


between the COM terminal signal has been provided;
B: tolerance; Waits IN10 signal is active, which means that when the
scales weighing tolerance allowed discharge;
C: No Discharge output; checking the discharge outlet and discharge
the output line.
Eight, no, the slow feed status
A: medium and slow feed rate is set too small, and increase (in) the
amount of slow progress
B: prohibited compare time setting is too long, set a reasonable time
prohibiting comparison, typically 0.3 to 1.5 seconds;
C: fast-forward amount is too large feed opening, in a wide range of
weighing scale, weighing less weight should be appropriate to slow
down the fast-added feed.
Tangshan...