DIN mount
(grey body)
Dual mount
(black body)
Dual mount
parallel
(black body)
Features
Applications
DC Circuit Breaker
Hydraulic-Magnetic technology
100% rating capability, independent of ambient temperature
VDE and CCC approved, CE certified
UL listed (UL 489 A)
Ratings 0.1 to 63 A (1 & 2 pole), 3 pole parallel
(150 A maximum), 4 pole parallel (200 A maximum)
Optional Auxiliary Switch / Trip Alarm - factory fitted
(6.5 mm wide)
Optional Shunt Trip (no approvals)
Wide range of time delays and operating currents
Precision tripping characteristics
Ultra compact 13 mm wide module
Trip indication with mid-trip handle
Reset immediately after overload
DIN mount product in grey shells
Dual mount product in black shells
80 V devices are reverse feedable
125 / 250 / 600 V devices are polarity sensitive
Suitable to use for electrical isolation
Dual mount
series
(black body)
Optional Accessories
AC and DC voltages
UL 489 listed (Auxiliary Switch: 6 A 250 V AC,
0.5 A 80 V DC)
IEC 60947-5-1 approved (Auxiliary Switch: 6 A 240 V AC,
0.5 A 110 V DC; Trip Alarm: 6 A 240 V AC, 0.5 A 110 V DC)
Factory fitted
Attached to right hand side of Circuit Breaker
Auxiliary Switch
Auxiliary Switch + Trip Alarm
Trip Alarm
Handle lock
Surface mounting clips
Busbar
57 mm Escutcheon blank
57 mm Safety blank
Data Sheet
Page 1 of 8
low voltage
Number of Poles
Operating Voltages
Minimum Current Rating
Maximum Current Rating
Interrupting Capacity
Operating Temperature
Range
Mounting Options
Time Delay Curves
80 V DC, 125 V DC
0.1 A
0.1 A
63 A
50 A
2 parallel
2 parallel
80 V DC
60 A
100 A
125 V DC
80 V DC
30 A
110 A
200 A
100 A
150 A
200 A
10 kA
Approvals
Number of Poles
Operating Voltages
Minimum Current Rating
Maximum Current Rating
Interrupting Capacity
Operating Temperature
Range
Mounting Options
Time Delay Curves
Breaker QY
2
parallel
80 V DC, 125 V DC 80 V DC
2 series
250 V DC
0.1 A
50 A
1 pole
plug-in
80 V DC
0.1 A
50 A
DIN Rail, Dual mounting (DIN & Mini), surface mounting clip, plug-in terminal
1, 9, U2, U3, OP
Operating Voltages
4 parallel
-40oC to +85oC
Approvals
Number of Poles
3 parallel
0.1 A
63 A
0.1 A
50 A
30 A
100 A
2
parallel
125 V
DC
20 A
100 A
UL 489A
3
4
parallel parallel
80 / 125
80 V DC
V DC
110 A
200 A
150 A
200 A
10 kA
2 series
4 series
250 V
DC
0.1 A
50 A
600 V
DC
0.1 A
20 A
1 pole
plug-in
80 V DC
0.1 A
50 A
-40oC to +85oC
DIN Rail, Dual mounting (DIN & Mini), surface mounting clip, plug-in terminal
1, 9, U2, U3, OP
CCC
1
0.1 A
63 A
0.1 A
50 A
2 parallel
3 parallel
80 V DC
30 A
110 A
100 A
150 A
10 kA
4 parallel
1 pole plug-in
200 A
200 A
0.1 A
50 A
-40oC to +85oC
DIN Rail, Dual mounting (DIN & Mini), surface mounting clip, plug-in terminal
1, 9, U2, U3, OP
Torque (IEC)
Torque (UL)
0.75 - 35 mm
18 2 AWG
2.5 Nm
20 in-lb
2 Pole Parallel
3 Pole Parallel
50 mm
95 mm
14 1/0 AWG
14 5/0 AWG
3.2 Nm
5.6 Nm
28 in-lb
50 in-lb
Comments
Pozidriv #2
Combi head
Bridge Terminal
Bridge Terminal
4 Pole Parallel
95 mm
14 5/0 AWG
5.6 Nm
50 in-lb
Bridge Terminal
Data Sheet
Page 2 of 8
QY-SERIES-DAT
DEC 2014
low voltage
10
11
12
QY
Frame
Switch /
Neutral
Auxiliary
Triple
pole
13 mm
module
width
DIN Rail
Medium
delay
curve U2
150 A
80 V DC
No Shunt
Trip
Future
use
Parallel
bridged
(by
customer)
Long Code
QY
(13)
U2
150A
B0
Group 1:
Frame Type
Code
Description
Comments
QY
Requirement
Group 2:
Code
Switch/Neutral
Group 3:
Code
Auxiliary
-
Group 4:
No of Poles
Description
Comments
Not applicable
Description
Comments
Not applicable
AT
Code
Description
Comments
Single pole
Double pole
Triple pole
Four pole
Group 5:
Module Width
Code
Description
Comments
(13)
13 mm module width
13 mm per pole
Group 6:
Mounting
Code
Description
Comments
DM
Group 7:
Time Delays
Code
Description
Comments
10 20
Orange handle
Group 8:
Current
Ratings
Group 9:
Voltage
(see diagram
on page 7)
7 12
White handle
U2
6 11
White handle
OP
Instantaneous
None
White handle
U3
35
White handle
Code / Description
0.1, 0.2, 0.3, 0.5, 1, 2, 3, 4, 5, 6, 7, 8 ,9, 10, 12, 15, 16, 20, 25, 30, 32, 35, 40, 45,
50, 60, 63, 70, 80, 90, 100, 120, 125, 150, 200 A
Code
Voltage
Description
B0
80 V DC
B1
125 V DC
B2
250 V DC
B3
250 V DC
B4
600 V DC
T1
125 V DC
T2
250 V DC
T3
250 V DC
T4
600 V DC
Comments
Ratings available vary depending on certification, bridging
configuration and voltage. (See comments in Group 9)
* Other ratings are available as special orders. Check availability.
Comments
0.1 - 63 A 1 pole, 0.1 - 50 A 2 pole, 60 - 100 A 2 pole parallel
(80 V DC), 30 - 100 A 2 pole parallel (125 V DC),
110 - 150 A 3 pole parallel, 200 A 4 pole parallel
(ratings available vary depending on certification)
0.1 - 50 A 2 pole series bridged at the top (by customer)
pole 1 (-) to pole 2 (+)
0.1 - 50 A 2 pole series bridged at the top (factory fitted)
pole 1 (-) to pole 2 (+)
0.1 - 20 A 4 pole series bridged (factory fitted)
As per wiring diagram printed on unit
0.1 - 63 A 1 pole, 0.1 - 50 A 2 pole, 30 - 100 A 2 pole parallel,
110 - 150 A 3 pole parallel, 200 A 4 pole parallel
0.1 - 50 A 2 pole series bridged at the bottom (by customer)
pole 1 (-) to pole 2 (+)
0.1 - 50 A 2 pole series bridged at the bottom (factory fitted)
pole 1 (-) to pole 2 (+)
0.1 - 20 A 4 pole series bridged (factory fitted)
As per wiring diagram printed on unit
Continues on page 4
QY-SERIES-DAT
DEC 2014
Data Sheet
Page 3 of 8
low voltage
Code
Description
Comments
Not applicable
V0
100 480 V
V5
100 480 V
Internally connected
Group 11
Code
Group 12:
Special
Termination
Code
Description
Comments
Not applicable
Plug-in
ZL
100000
OPERATING
CHARACTERISTICS
10000
CURVE 1
1000
100
10
Maximum
0.01
1500
100000
0.1
OPERATING
CHARACTERISTICS
10000
CURVE 9
4000
5000
3000
2500
2000
1500
1000
500
400
300
200
130
100
105
1000
% Rated Current
100
10
0.1
Maximum
0.01
Data Sheet
Page 4 of 8
QY-SERIES-DAT
DEC 2014
% Rated Current
4000
5000
3000
2500
2000
1500
1000
500
400
300
200
100
105
0.001
130
Maximum
150
0.001
150
Maximum
low voltage
100000
OPERATING
CHARACTERISTICS
10000
CURVE U2
1000
100
10
0.1
Maximum
0.01
4000
5000
3000
2000
2500
1500
1000
500
400
300
200
130
100
105
0.001
150
Maximum
% Rated Current
1500
100000
OPERATING
CHARACTERISTICS
10000
CURVE U3
1000
100
10
0.1
Maximum
0.01
4000
5000
3000
2000
1500
1000
500
400
300
200
130
100
105
0.001
150
Maximum
% Rated Current
QY-SERIES-DAT
DEC 2014
Data Sheet
Page 5 of 8
low voltage
100000
OPERATING
CHARACTERISTICS
10000
CURVE OP
1000
100
10
0.1
Maximum
0.01
5000
4000
3000
2000
2500
1500
1000
500
400
300
200
130
100
105
0.001
150
Maximum
% Rated Current
* The published time delay curves are generated at 30 C ambient temperature with the Circuit Breaker mounted in the up-right position. The must hold, must trip and instantaneous
trip current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which
is available on request.
o
10,000
Resistance (m )
1,000
100
10
Maximum
0.1
Data Sheet
Page 6 of 8
Maximum
10
15
QY-SERIES-DAT
DEC 2014
20
25
30
35
Amp rating
40
45
50
55
60
65
low voltage
45
16
18
11
12
15
16
V
D E
11
12
14
A005438
Q-AUX
57.0
97.2
TEST BUTTON
(not on Auxiliary)
15
14
18
12
15
6.0
Uimp = 2.5kV
Icw = 0.1kA
UTIL. CAT. AC12/DC12
POLLUTION DEGREE 3
18
18.0
RoHS
11
19.3
Auxiliary Switch
16
CONNECTING TERMINALS
DETAIL (COMMON TO ALL)
35.5
Circuit Diagrams
Trip Alarm Switch
0.5
All dimensions in mm
Tolerance 0.2 unless otherwise specified
All widths are maximum
2.3
0.8
1.4
6.8
2.80
Typical outline for an Auxiliary module
attached to a Dual mount single pole
Circuit Breaker
14
11.7
69.8
6.5
18.0
37.8
Polarity identification
Diagram identifying the polarity of 125 V DC products in reference to Group 9 on page 3. Devices are shown viewed from the
front. Series devices (standard) - each pole is opposite polarity from the next pole on the left (bridged - to +). Parallel devices
- each pole has the same polarity (bridged + to +, - to -).
Series Bridged
Parallel Bridged
Positive Top
4 Poles
Pole 1
(Positive Bottom)
2 Poles
Pole 1
(Positive Top)
1 Pole
1 Pole
Positive Bottom
Polarity
Marking
Bottom (Load
side)
QY-SERIES-DAT
DEC 2014
Data Sheet
Page 7 of 8
low voltage
6.186
157.1 (Ref)
6.071
154.2 (Ref)
142.0 (Ref)
1.024
2.801
71.2
3.827
97.2 (Ref)
2.244
57.0
3.244
0.772
82.4
26.0
0.512
5.591
2.400
19.6
52.0
2.048
39.0
1.536
26.0
1.024
19.6
13.0
0.772
5.0
0.512
45.0
0.197
Maximum cable
50 mm2
1.772
All dimensions in mm [ inch ]
Tolerance 0.2 [ 0.008 ] unless otherwise specified
All widths are maximum
64.8
2.551
Maximum cable
95 mm2
Maximum cable
95 mm2
6.186
157.1 (Ref)
6.071
142.0 (Ref)
2.803
71.2
3.827
97.2 (Ref)
1.772
45.0
154.2 (Ref)
1.024
0.512
3.244
82.4
26.0
13.0
0.732
5.591
2.362
18.6
52.0
2.048
39.0
1.536
26.0
1.024
18.6
13.0
0.732
5.0
0.512
44.0
0.197
1.732
63.8
2.512
Maximum cable
50 mm2
Maximum cable
95 mm2
Maximum cable
95 mm2
AUSTRALIA
CBI-electric: Australia
90 Fairbank Road Clayton South
Melbourne Victoria 3169 Australia
Tel: + 61 39590 3500
Fax: +61 3 9551 1051
Email: sales@cbi-electric.com.au
Website: www.cbi-electric.com.au
Data Sheet
Page 8 of 8
QY-SERIES-DAT
DEC 2014
SOUTH AFRICA
USA
Group