Signal Fitness-For-Service Report

Input Data
Assessment Information:
Assessment Type: General Metal Loss
Design Code: ASME Section VIII Div 1
FFS Code: June 2007 API 579-1/ASME FFS-1
Units: lbs - in - psi
RSFa: 0.9
Analysis By: MZW
Project Information: D-8133

Equipment Inputs:
Equipment: Pressure Vessel
Nominal Thickness: 0.785 in
Inside Radius: 9.21 in
Circumferential Weld Joint Factor: 1
Longitudinal Weld Joint Factor: 1
Minimum Thickness
Minimum thickness = 0.397

Material Properties:
Material: ASME Section VIII Div 1
Design Temperature: 200F

Operating Condition Inputs:


Pressure Type: Internal Pressure
Pressure: 1350 psi
Internal Uniform Metal Loss: 0.388 in
External Uniform Metal Loss: 0 in
Internal Future Corrosion Allowance: 0 in
External Future Corrosion Allowance: 0 in

Results Summary
Part 4 Level 1
MAWPr must be greater than Design Pressure.
Does not satisfy June 2007 API 579-1/ASME FFS-1 Level 1 assessment.
(Refer To: June 2007 API 579-1/ASME FFS-1 )

Part 4 Level 2
MAWPr must be greater than Design Pressure.
Does not satisfy June 2007 API 579-1/ASME FFS-1 Level 2 Assessment.
(Refer To: June 2007 API 579-1/ASME FFS-1 )

Step By Step Results


Part 4 Level 1
MAWPr must be greater than Design Pressure.
Does not satisfy June 2007 API 579-1/ASME FFS-1 Level 1 assessment.
(Refer To: June 2007 API 579-1/ASME FFS-1 )
Analysis done according to June 2007 API 579-1/ASME FFS-1

Step 1: Determine the minimum required thickness.


TminL = 0.320 in
TminC = 0.675 in
Tsl = 0.000 in
Tmin = 0.675 in

Step 2: Evaluate the thickness data.


Tmm = 0.397 in

Step 3: Determine the wall thickness to be used.


Tc = 0.397 in

Step 4: Determine the remaining thickness ratio.


Rt = 1.000 in

Step 5: Determine the length for thickness averaging.


Q = 50.000
L = 138.029 in

Step 6: Determine thickness averages.


Date: 1/22/2015
Generated By:SignalFitnessForServiceStandardEdition,Version2014.0902
Signal FFS is written and maintained by Quest Integrity Group, a Team Industrial Services company

Page 1 of 2

TamC = 0.397 in
TamS = 0.397 in

Step 7: Determine the acceptability for continued operation.


TamS - FCA >= TminC ? No: 0.397 < 0.675
Averaged longitudinal thickness must be greater than t_minC.
TamC - FCA >= TminL ? Yes: 0.397 >= 0.320
Tmm - FCA >= 0.338 ? Yes: 0.397 >= 0.338
MAWPr = 807.222 psi
MAWPr >= MAWP ? No: 807.222 < 1350.000
MAWPr must be greater than Design Pressure.

Part 4 Level 2
MAWPr must be greater than Design Pressure.
Does not satisfy June 2007 API 579-1/ASME FFS-1 Level 2 Assessment.
(Refer To: June 2007 API 579-1/ASME FFS-1 )
Analysis done according to June 2007 API 579-1/ASME FFS-1

Step 1: Determine the minimum required thickness.


TminL = 0.320 in
TminC = 0.675 in
Tsl = 0.000 in
Tmin = 0.675 in

Step 2: Evaluate the thickness data.


Tmm = 0.397 in

Step 3: Determine the wall thickness to be used.


Tc = 0.397 in

Step 4: Determine the remaining thickness ratio.


Rt = 1.000 in

Step 5: Determine the length for thickness averaging.


Q = 50.000
L = 138.029 in

Step 6: Determine thickness averages.


TamC = 0.397 in
TamS = 0.397 in

Step 7: Determine the acceptability for continued operation.


TamS - FCA >= TminC*RSFa ? No: 0.397 < 0.608
Averaged longitudinal thickness must be greater than t_minC*RSFa.
TamC - FCA >= TminL*RSFa ? Yes: 0.397 >= 0.288
Tmm - FCA >= 0.338 ? Yes: 0.397 >= 0.338
MAWPr = 894.507 psi
MAWPr >= MAWP ? No: 894.507 < 1350.000
MAWPr must be greater than Design Pressure.

Figures

Date: 1/22/2015
Generated By:SignalFitnessForServiceStandardEdition,Version2014.0902
Signal FFS is written and maintained by Quest Integrity Group, a Team Industrial Services company

Page 2 of 2