1. MASTER ELEMENT
2 . T I M E D E L AY S TA RT I N G O R C L O S I N G R E L AY
3 . C H E C K I N G O R I N T E R L O C K I N G R E L AY
4 . M A S T E R C O N TA C T O R
5. STOPPING DEVICE
Top
6 . S TA RT I N G C I RC U I T B R E A K E R
7 . A N O D E C I RC U I T B R E A K E R
1 0 . U N I T S E Q U E N C E S W I TC H
Top
1 1 . R E S E RV E D F O R F U T U R E A P P L I C AT I O N
1 2 . OV E R- S P E E D D E V I C E
1 4 . U N D E R- S P E E D D E V I C E
is a device that functions when the speed of a machine fall below a pre
-determined value.
1 5 . S P E E D O R F R E Q U E N C Y M ATC H I N G D E V I C E
Top
1 6 . R E S E RV E D F O R F U T U R E A P P L I C AT I O N
1 7 . S H U N T I N G O R D I S C H A R G E S W I TC H
1 9 . S TA RT I N G -T O - R U N N I N G T R A N S I T I O N C O N TA C T O R
2 0 . VA LV E
Top
2 1 . D I S TA N C E R E L AY
2 2 . E Q U A L I Z E R C I RC U I T B R E A K E R
2 3 . T E M P E R AT U R E C O N T R O L D E V I C E
is a device that operates when two a-c circuits are within the desired
limits of frequency, phase angle, or voltage, to permit or to cause the
paralleling of these two circuits
Top
2 6 . A P PA R AT U S T H E R M A L D E V I C E
2 7 . U N D E RV O LTA G E R E L AY
2 9 . I S O L AT I N G C O N TA C T O R
3 0 . A N N U N C I AT O R R E L AY
Top
3 1 . S E PA R AT E E XC I TAT I O N D E V I C E
3 2 . D I R E C T I O N A L P O W E R R E L AY
3 3 . P O S I T I O N S W I TC H
3 5 . B R U S H - O P E R AT I N G O R S L I P P I N G S H O RT- C I RC U I T I N G
DEVICE
Top
3 6 . P O L A R I T Y O R P O L A R I Z I N G V O LTA G E D E V I C E
3 7 . U N D E RC U R R E N T O R U N D E R P O W E R R E L AY
4 0 . F I E L D R E L AY
Top
4 1 . F I E L D C I RC U I T B R E A K E R
4 2 . R U N N I N G C I RC U I T B R E A K E R
4 3 . M A N U A L T RA N S F E R O R S E L E C T O R D E V I C E
4 4 . U N I T S E Q U E N C E S TA RT I N G R E L AY
is a relay that function to start the next available unit in a multipleunitequipment upon the failure or non-availability of the normally
preceding unit.
4 5 . AT M O S P H E R I C C O N D I T I O N M O N I T O R
Top
4 6 . R E V E R S E P H A S E O R P H A S E B A L A N C E C U R R E N T R E L AY
is a relay that functions when the polyphase currents are of reversephase sequence, or when the polyphase currents are unbalanced or
contain negative phase-sequence components above a given amount.
4 7 . P H A S E - S E Q U E N C E V O LTA G E R E L AY
4 8 . I N C O M P L E T E S E Q U E N C E R E L AY
4 9 . M A C H I N E O R T R A N S F O R M E R T H E R M A L R E L AY
Top
5 1 . A - C T I M E O V E RC U R R E N T R E L AY
5 2 . A - C C I RC U I T B R E A K E R
5 3 . E XC I T E R O R D - C G E N E R AT O R R E L AY
is a relay that forces the d-c machine field excitation to build up during
starting or which functions when the machine voltage has been built
up to a given value.
5 4 . H I G H - S P E E D D - C C I RC U I T B R E A K E R
5 5 . P O W E R FA C T O R R E L AY
is a relay that operates when the power factor in an a-c circuit rises
above or falls below a predetermined value.
Top
5 6 . F I E L D A P P L I C AT I O N R E L AY
5 7 . S H O RT- C I RC U I T I N G O R G R O U N D I N G D E V I C E
5 8 . R E C T I F I C AT I O N FA I LU R E R E L AY
5 9 . O V E RV O LTA G E R E L AY
6 0 . V O LTA G E O R C U R R E N T B A L A N C E R E L AY
Top
6 1 . R E S E RV E D F O R F U T U R E A P P L I C AT I O N .
6 2 . T I M E - D E L AY S T O P P I N G O R O P E N I N G R E L AY
6 3 . L I Q U I D O R G A S P R E S S U R E O R VA C U U M R E L AY
6 4 . G R O U N D P R O T E C T I V E R E L AY
Note: This function is assigned only to a relay that detects the flow of
current from the frame of a machine or enclosing case or structure of
piece of apparatus to ground, or detects a ground on a normally
ungrounded winding or circuit. It is not applied to a device connected
in the secondary circuit of current transformer, in the secondary
neutral of current transformers, connected in the power circuit of a
normally grounded system.
65. GOVERNOR
Top
6 6 . N O TC H I N G O R J O G G I N G D E V I C E
6 7 . A - C D I R E C T I O N A L O V E RC U R R E N T R E L AY
6 8 . B L O C K I N G R E L AY
7 0 . R H E O S TAT
Top
7 1 . L I Q U I D O R G A S - L E V E L R E L AY
7 2 . D - C C I RC U I T B R E A K E R
7 3 . L O A D - R E S I S T O R C O N TA C T O R
7 4 . A L A R M R E L AY
Top
7 6 . D - C O V E RC U R R E N T R E L AY
7 7 . P U L S E T RA N S M I TT E R
is used to generate and transmit pulses over a telemetering or pilotwire circuit to the remote indicating or receiving device.
7 8 . P H A S E - A N G L E M E A S U R I N G O R O U T- O F - S T E P
P R O T E C T I V E R E L AY
7 9 . A - C R E C L O S I N G R E L AY
is a relay that controls the automatic reclosing and locking out of an ac circuit interrupter.
8 0 . L I Q U I D O R G A S F L O W R E L AY
Top
8 1 . F R E Q U E N C Y R E L AY
8 2 . D - C R E C L O S I N G R E L AY
8 3 . A U T O M AT I C S E L E C T I V E C O N T R O L O R T R A N S F E R R E L AY
8 4 . O P E R AT I N G M E C H A N I S M
8 5 . C A R R I E R O R P I L O T- W I R E R E C E I V E R R E L AY
Top
8 6 . L O C K I N G - O U T R E L AY
8 7 . D I F F E R E N T I A L P R O T E C T I V E R E L AY
8 8 . A U X I L I A RY M O T O R O R M O T O R G E N E R AT O R
8 9 . L I N E S W I TC H
9 0 . R E G U L AT I N G D E V I C E
Top
9 1 . V O LTA G E D I R E C T I O N A L R E L AY
9 2 . V O LTA G E A N D P O W E R D I R E C T I O N A L R E L AY
disconnected from each other when the power flowing between them
exceeds a given value in the opposite direction.
9 3 . F I E L D - C H A N G I N G C O N TA C T O R
9 4 . T R I P P I N G O R T R I P - F R E E R E L AY
9 5 . * ( U S B R A S S I G N E D C L O S I N G R E L AY O R C O N TA C T O R )
Top
96.*
97.*
9 8 . * ( U S B R A S S I G N E D L O S S O F E XC I TAT I O N R E L AY )
9 9 . * ( U S B R A S S I G N E D A RC D E T E C T O R )
Auxiliary Devices
CS Control Switch
L Lowering Relay
1. Opening Relay
PB Push Button
R Raising Relay
X Auxiliary Relay
Y Auxiliary Relay
Z Auxiliary Relay