Multisim features a comprehensive suite of SPICE analyses for examining circuit behavior. These analyses range from the basic to sophisticated. Each analysis helps you to obtain valuable
information such as the effects of component tolerances and sensitivities. For each analysis you need to set settings that will inform Multisim exactly what to analyze, and how.
Multisim simplifies the procedure for an advanced analysis by providing a configuration window. This abstracts away the complexities associated with SPICE syntax and configuration of an
analysis. With this window you merely need to specify the parameter values and output nodes of interest.
This tutorial is part of the National Instruments SPICE Analysis Fundamentals Series. Each tutorial in this series provides you with step-by-step instructions on how to configure and run the
different SPICE analyses available in Multisim.powerful simulation and analysis while abstracting the complexity of SPICE syntax.
Table of Contents
1. Introduction
2. Running DC Operating Point Analysis
3. Additional Resources
1. Introduction
DC Operating Point Analysis calculates the behavior of a circuit when a DC voltage or current is applied to it. The result of this analysis is generally referred as the bias point or quiescent point,
Q-point. In most cases, the results of the DC Operating Point Analysis are intermediate values for further analysis. For example, in AC Analysis, the DC operating point is first calculated to obtain
linear, small-signal models for all nonlinear components (such a diodes and transistors).
Assumptions: AC sources are zeroed out, capacitors are open, inductors are shorted, digital components are treated as a large resistor to ground.
1/3
www.ni.com
(a)
2/3
www.ni.com
(b)
Figure 4. Reduced circuit to calculate the DC operating point.
Use the following expressions to calculate the collector voltage, VC:
Divider current:
Base voltage:
Emitter voltage:
Emitter current:
Collector current:
Collector voltage:
Note that this calculation (VC = 4.81 V) matches the result obtained by the DC Operating Point Analysis in Multisim.
Since the DC Operating Point Analysis is often performed as the first step of other analyses, it is important to know how to solve convergence problems and analysis failures. Refer to the
Troubleshooting DC Operating Point Analysis Failures article to learn more about it.