Sie sind auf Seite 1von 4

INSTRUMENT DATASHEET FOR

COMPUTER

FLOW

DOCUMENT NO.

GENERAL

BASIC

OPERATOR INTERFACE
SECURITY
CPU MODULE

I/O MODULE

1
2
3
4
5
6
7
8
9
10
11
12
13

Tag No
P&ID No
Service
Line No
Description
Operation Temperature
Relative Humidity
Storage Temperature
Safety Class
Dimension
Weight
Installation Type
Supply Voltage

14
15
16
17
18

Display
Indicator
Data Entry
Software
Hardware

19
20

Processor
Memory

21
22
23
24

Real Time Clock Built-in


Battery Backup
Battery Life Span
Analog Input
- Current Input 4-20mA
- Voltage Input 1 - 5 VDC
- RTD Input
- Resolusition
- Accuracy
Analog Ouput
- Current Input 4-20mA
- Voltage Input 1 - 5 VDC
- Resolusition
- Accuracy
Digital I/O
- Pulse Input
- Frequency Input
Serial Communication
- RS 232C
- RS 485
- Speed
- Protocol support
Ethernet Communication
- Speed
- Connection
- Protocol support

25

26

27

28

CALCULATION

29
30

Hart Communication Support


Gas Partial

31

Liquid

D
C
B
A
REV

DATE

Deg.F
RH
Deg.F
In
lbs
VAC
VDC

VDC
Years

ISSUED FOR REVIEW


DESCRIPTION

FQI-100B
RSS-PEP-M100-PID-01
Natural Gas
Stream-2
Flow Computer
14 to 140
90% non-condensing
-4 to 158
EMC, EN55022-B, EN61000-4, IEC
8.25 x 4.75 x 8.75
9
Panel Mount
90 to 264 V
22 to 26 V
LCD display with 4-Lines of 20 alp
4 Led, dual color (Red, Green)
34-key, domed, membrane, with
Multi-level password control
Optional lock/seal on housing plu
lockout switch
32-bit, 150 MHz Maximum
Flash RAM : 4 MB
Fast RAM : 4 MB
Storage : 2 MB with battery backu
YES
3.6 NiMH
5-7
Up to 8 Input per CPU
YES, up to 8 input
YES, up to 8 input
YES, up to 4 input
14 bits
0.025% of reading at 41 to 122
Up to 4 Output per CPU
YES
YES
12-bits
10 ppm (Frequency)
Up to 12 I/O per Module
YES
YES, 0 - 15 kHz
Up to 4 Port per CPU
YES, isolated
YES, isolated
Up to 38400 kbps
OMNI Modbus, Serial Modbus
Up to 1 port per CPU
10 MBps
Up to 8 simulaneous connection
OMNI Modbus, Serial Modbus, Mo
TCP, UDP
YES
AGA 3 (US & Metric), AGA 5, AGA
Modified AGA NX19, GPA 2172, IS
S-GERG, NIST14, Steam NIST & A
ASTM D1250(1952) Tables 5/6, 23
API MPMS Ch.11.1 (1980) & (2004
(1983),11.2.2, 11.2.1M, 11.2.2 M

CALCULATION

APROVAL
PURCHASE

Notes:

32
33

Prover
Approval & Compliance

30
31
32
33
34

Manufacture
Model No
Manufacture
Firmware
Config

Unidirectional, Bi-directional pipe


UL, CSA, CE, MID, European Dire
OIML D031, EN12405 Part 1; WEL
Indian W&M, LNE
OMNI Flow Computer
3000
Omni
23.75
1D-1S-2A

PT. REXAUDIA SASADA SENTOSA

SUED FOR REVIEW


DESCRIPTION

CHK

ENG

RSS

QI-100B
SS-PEP-M100-PID-01
atural Gas
ream-2
ow Computer
4 to 140
0% non-condensing
to 158
MC, EN55022-B, EN61000-4, IEC-EN 61000-6-2
25 x 4.75 x 8.75

anel Mount
0 to 264 V
2 to 26 V
CD display with 4-Lines of 20 alphanumeric
Led, dual color (Red, Green)
4-key, domed, membrane, with tactile and audia feedback
ulti-level password control
ptional lock/seal on housing plus internal keyboard program
ckout switch
2-bit, 150 MHz Maximum
ash RAM : 4 MB
ast RAM : 4 MB
orage : 2 MB with battery backup
ES
6 NiMH
-7
p to 8 Input per CPU
ES, up to 8 input
ES, up to 8 input
ES, up to 4 input
4 bits
0.025% of reading at 41 to 122 Deg.F
p to 4 Output per CPU
ES
ES
2-bits
0 ppm (Frequency)
p to 12 I/O per Module
ES
ES, 0 - 15 kHz
p to 4 Port per CPU
ES, isolated
ES, isolated
p to 38400 kbps
MNI Modbus, Serial Modbus
p to 1 port per CPU
0 MBps
p to 8 simulaneous connection
MNI Modbus, Serial Modbus, Modbus TCP, LDP, Syslog, Telnet,
CP, UDP
ES
GA 3 (US & Metric), AGA 5, AGA 7, AGA 8, AGA 10, AGA 11,
odified AGA NX19, GPA 2172, ISO 5167, ISO 6976, ISO12213-3,
GERG, NIST14, Steam NIST & ASME, Redlich-Kwong
STM D1250(1952) Tables 5/6, 23/24, 53/54, 59/60;
PI MPMS Ch.11.1 (1980) & (2004-2007) , API MPMS Ch.11.2.1
1983),11.2.2, 11.2.1M, 11.2.2 M,

PEP

nidirectional, Bi-directional pipe, Master Meter


L, CSA, CE, MID, European Directive 2004/22/EC, OIML R117-1,
IML D031, EN12405 Part 1; WELMEC 7.2 & 8.8, NMi, GOST, PAC,
dian W&M, LNE
MNI Flow Computer
000
mni
3.75
D-1S-2A

Das könnte Ihnen auch gefallen