WARRANTY
The Product MP - Series ( Micro - Controller
based Annunciator) is backed up by Alan's warranty
against all manufacturing defects at our works for 18
months from the date of supply or 12 months from the
date of installation, which ever is earlier.
CONTENTS
Topic
Sr.No.
Page No.
1.
General
2.
Features
3.
Technical Specifications
4.
Construction
5.
6.
7.
13
8.
14
9.
Dimensional Details
15
10.
Ordering Information
20
GENERAL
The world is going through automation in each
and every field. Any manufacturing controlling system
requires centralized monitoring. Annunciator is one of
the equipments among these systems. After studying
numerous site requirements, Alan Electronic Systems
Pvt. Ltd, have developed and perfected the Annunciator
with latest technology. The user friendly design fulfills
the expectations and demands of the customer.
FEATURES
SALIENT FEATURES
1. Micro-controller based logic.
2. Built in watchdog monitoring design to ensure failsafe
working.
3. Asthetically designed light in weight, with compact
enclosure.
4. Facia windows with long life super bright LEDs.
5. Three operating sequences in single card.
6. Synchronisation of window flashing in group Annun
-ciation.
7. Reliable Membrane type push buttons for Test,
Silence, Accept, and Reset functions.
8. Standard Modules :- 1, 2 ,4, 6, 8, 11, 15, 19 and 23
Windows and any custom built Systems.
9. NO / NC, T / NT , M / N / S Sequence Selection by
DIP Switch at site.
1
OPTIONAL FEATURES
TECHNICAL SPECIFICATION
Supply Voltage
Number of windows
Power consumption
Response time
Flashing rate
Standard sequences
Optional sequences
Legends
Push buttons
Type tests
CONSTRUCTION
FRONT FACIA
Customer has choice of two sizes of windows
depending upon their facia description. It is made of
ABS plastic and illuminated by group of super bright
LEDs. LEDs have long life ( 108 hours ). Thus reduces
replacement cost of bulbs and also maintenance.
CONTROL CARD
All type of selections and Micro - Controller are
situated on this card. Sequence selection, NO/NC fault
contacts selection, Trip and Non-Trip audible selection
are provided by DIP Switch selection.
POWER SUPPLY UNITE
Power Supply Unit is available in two ranges.
A) 88-320 V AC/DC
B) 18-90V DC. These power supplies are designed
to work in extreme conditions.
FAULT SENSING TERMINEL
The fault or event sensing terminals provided,
depending upon number of channels at rear side.
PUSH BUTTONS
The built in membrane type Push buttons is
applicable only for Single Module. In multi-module Ann
-unciation the external push buttons are made common
to control whole annunciation system. Terminals for exte
-rnal Push buttons are provided on rear side.
5
AUDIO ALARM
One NO type potential free relay contacts each
for actuating the external hooter for Trip and Non Trip
audible alarm. For Trip AT-AT and for Non-Trip AN-AN
legend is marked. NO type potential free relay contacts
for Ring back (R) and Dome light facility are optional.
Operation Test
Silence
Accept
Reset
7
-------
Open
Close
Close
Close
Close
Open
----------------Silence
Accept
Reset
Reset
OFF
Flashing
Flashing
Steady ON
Steady ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
Open
Close
------------Close
------------Open
--------OFF
--------Flashing
Silence
Flashing
Accept Steady ON
Reset
Flashing
Silence & Flashing
Accept Steady ON
Reset
OFF
8
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
Open
---------
OFF
OFF
Abnormal
--------
Close
-------
---------
Flashing
ON
Silence
Flashing
OFF
--------
Close
Accept
Steady ON
OFF
-------
Open
-------
OFF
OFF
---------
OFF
OFF
Close
Close
---------
Flashing
ON
Silence
Flashing
OFF
--------
Close
Accept
Steady ON
OFF
-------
Open
-------
Slow
Flashing
ON
-------
-------
Reset
OFF
OFF
Normal
Abnormal
--------
Facia
(Window)
Audio
Alarm
Normal
Open
------
OFF
OFF
Abnormal
------
------
------
------
First Fault
Close
------
Fast Flashing
ON
Subsequent
Fault
Close
Slow Flashing
(F1)
------
Steady ON
(F2)
------
OFF Condition
(F3)
------
------
Silence
Same As
Above
OFF
------
------
Accept
Steady ON
OFF
Subsequent
------
-------
------
Accept
Both
Steady ON
OFF
-------
Both Open
Reset
OFF
OFF
Fast Flashing
10
11
Push
Up
Pull
Towards
BU
C
HH
TR OLZ
IP
12
Press Test PB
No No
Audio
relay
Closed
Press Mute PB
All
Windows
Flashing
Is
Fuse
O.K
No No
Alarm
OFF
Yes
No
Switch
OFF the
Supply
and
replace
the Fuse
with same
Rating
Press Accept PB
All
Windows
Steady
ON
No
Consult Alan
Yes
Press Reset PB
All
Windows
Off
Yes
End
Assumption
NO - Fault Contacts
Manual Reset (M) Seq.
No
14
DIMENSIONAL DETAILS
MP 03 SERIES
1 WAY
92
96
W1
96
92
PWR
ON
ALAN
ALARM ANNUNCIATOR
CUTOUT
ELEVATION
2 WAY 1CX2R
92
96
W1
W2
96
92
PWR
R
ON
CUTOUT
ELEVATION
4 WAY (2CX2R)
92
96
MP- 03
W1
ALAN
W3
W2
92
PWR ON
W4
CUTOUT
ELEVATION
15
96
8 WAY (2CX4R)
138
144
MP-SERIES
ALAN
W1
W2
W3
W4
W5
W6
W7
W8
138
144
CUTOUT
ELEVATION
12 WAY (3CX4R)
168
172
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
138
144
ELEVATION
CUTOUT
16
DIMENSIONAL DETAILS
MP 02 SERIES
6 WAY (3CX3R)
265
230
MP- SERIES
165
W1
W2
W3
W4
W5
W6
135
PWR
MUTE AKN
RST TEST
ON
ALAN Alan
CUTOUT
ELEVATION
8 WAY (3CX3R)
230
265
MP- SERIES
165
W1
W2
W3
W4
W5
W6
W7
W8
ALAN Alan
135
PWR
MUTE AKN
RST TEST
ON
CUTOUT
ELEVATION
11 WAY (3CX4R)
MP- SERIES
W1
W2
W3
W4
W5
W6
W7
W8
W10
W11
ALAN Alan
W9
PWR
MUTE AKN
RST TEST
ON
ELEVATION
17
CUTOUT
15 WAY (4CX4R)
307
342
MP- SERIES
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W13
W14
W15
ALAN Alan
W12
205
175
PWR
MUTE AKN
RST TEST
ON
CUTOUT
ELEVATION
19 WAY (5CX4R)
307
342
MP- SERIES
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
W13
W14
W15
W16
W19
PWR
W17
ALAN Alan
W18
MUTE AKN
215
245
RST TEST
ON
CUTOUT
ELEVATION
23 WAY (6Cx4R)
342
307
MP- SERIES
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W21
W22
W23
ALAN Alan
255
285
W20
PWR
MUTE AKN
RST TEST
ON
CUTOUT
ELEVATION
16
29 WAY (6CX5R)
500
ALAN
235
MP- SERIES
W1
W2
W3
W4
W5
W6
W7
W8
W9
W10
W11
W12
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
PWR
MUTE AKN
ON
RES TEST
CUTOUT
ELEVATION
35 WAY (6CX6R)
500
467
MP- SERIES
W1
275
W2
W3
W4
W5
W10
W11
W6
W7
W8
W13
W14
W15
W16
W17
W18
W19
W20
W21
W22
W23
W24
W26
W27
W28
W29
W30
W35
PWR
W25
W31
ALAN Alan
W9
W32
W33
W34
W12
MUTE AKN
250
RST TEST
ON
ELEVATION
CUTOUT
47 WAY (8CX6R)
651
621
MP- SERIES
275
W1
W2
W3
W5
W6
W7
W12
W13
W14
W15
W8
W9
W10
W17
W18
W19
W20
W21
W22
W23
W24
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W41
W42
W43
W44
W45
W46
W47
ALAN Alan
W11
W4
W16
W40
PWR
MUTE AKN
RST TEST
ON
CUTOUT
ELEVATION
63 WAY (8CX8R)
651
MP- SERIES
355
W1
W2
W3
W11
W4
W5
W6
W7
W8
W12
W13
W14
W15
W16
W9
W10
W17
W18
W19
W20
W21
W22
W23
W25
W26
W27
W28
W29
W30
W31
W32
W33
W34
W35
W36
W37
W38
W39
W40
W42
W43
W44
W45
W46
W47
W49
W50
W51
W52
W53
W54
W55
W57
W58
W59
W60
W61
W62
W63
W41
ALAN Alan
621
W24
W48
W56
PWR
RST TEST
MUTE AKN
ON
ELEVATION
19
CUTOUT