MODEL - 1005/1005A

DIAL TYPE THERMOMETER

STANDARD OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches

1005/1005A

Specifications
Temperature Range

Model : 1005
0 -1500C, 0 -1600C, 30 -1500C,
-20 to 1400C
150mm (6) Round
2700
10C
1% of FSD
5
15% - 85%

Model : 1005A
0 -1500C, 0 -1600C, 30 -1500C,
-20 to 1400C
150mm (6) Round
2700
10C
1% of FSD
5
15% - 85%

3A @ 250V AC/DC
Magnetic Blowout Micro switch

15A @ 250V AC
0.5A @ 250V DC
Standard Micro switch

S1 & S2: 3C to 9C (630C)Fixed


S3 to S5: 8C to 400C Adjustable.
2.5 0C of Set Value
Available (Potentiometer Output)
Up to 25 Mtrs
Available
Press Fit Wago Type
IP 55(IEC - 60529)
2.5 KV AC, 50Hz/60Hz for
1 minute; all Terminals to ground

S1 & S2: 3C to 90C (630C)Fixed


S3 to S5: 80C to 400C Adjustable.
2.50C of Set Value
Available (Potentiometer Output)
Up to 25 Mtrs
Available
Press Fit Wago Type
IP 55(IEC - 60529)
2.5 KV AC, 50Hz/60Hz for
1 minute; all Terminals to ground

Electrical entry

M20 - 3Nos

M20 - 3Nos

Cable Gland

Optional

Optional

Thermometer Pocket

Optional

Optional

Dial Size
Dial angular Sweep
Dial Graduation
Accuracy Class
Max. No. of Switches
Switching Range
Contact Rating
Switch Differential
Switching Accuracy
Remote Repeater
Max. Capillary Length
Switch Test Knob
Electrical Connection
Degree of Protection
High Voltage Test

Remote Repeater 96 Sq
Specifications
Type

4 digits, 0.5 Seven Segments LEDs

Auxillary Supply

90 260V AC/DC

Resolution

0.10C

Degree of protection of enclosure

IP 20

Operating Temperature Range

00C to 600C

Signal output

4 sets of 4 - 20mA DC
Optional RS 485

Cutout dimension

92 Sq. mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Cold and Dry Test :


-40C to +70C

3.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

4.

Salt Spray Test :


For polyester powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

5.

Micro Switch rating Test :


a) ML - 1005:
3A @ 250V AC &
3A @ 250V DC

b) ML - 1005A:
15A @250V AC &
0.5A @250V DC

Ordering Information
Model
Type of Instrument
Range

No. of Switches

Switch Configuration
Capillary Length
Union Type

Repeater
If WTI please specify

1005 /1005A
OTI / WTI
R1. 0 - 150C
R2. 0 - 160C
R3. 30 - 150C
R4. -20 to140C
(other ranges on request)
S2 - 2switches
S3 - 3switches
S4 - 4switches
S5 - 5switches
L - Normally open contact
L2 - Changeover contact
C1 - 1mts
C2 - 2mts....... upto C25 - 25mts
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
Y - Requried
N - Not Required
Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)

Note: WTI Gradient is factory set. If required customer can adjust as per requirement.
Sample Ordering Information :1005\WTI\R3\S2\L2\C2\U1\Y\........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1005H/1005AH
DIAL TYPE THERMOMETER

Hybrid OTI / WTI

General Features

The fully sealed liquid expansion in the system provides a self powered indication and operation to
the instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master
indication.
Current Converter Unit (CCU) is mounted inside the Local OTI/WTI, The output from which can be
connected to remote indicator or SCADA are a combination of both.
For the WTIs additional Winding temperature simulator is provided
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches
ML : 1005H/1005AH

Specifications
Temperature Range

Model : 1005H
0-1500C, 0-1600C, 30-1500C,
-20 to 1400C
150mm (6) Round
2700
10C
1% of FSD
5
15% - 85%

Model : 1005AH
0-1500C, 0-1600C, 30-1500C,
-20 to1400C
150mm (6) Round
2700
10C
1% of FSD
5
15% - 85%

3A @ 250V AC/DC
Magnetic Blowout Micro switch

15A @ 250V AC
0.5A @ 250V DC
Standard Micro switch

Electrical entry

S1 & S2: 3C to 9C (630C) Fixed


S3 to S5: 8C to 400C Adjustable.
2.5 0C of Set Value
Available / 4 - 20mA / RS - 485
Up to 25 Mtrs.
Available
Press Fit Wago Type
IP 55(IEC-60529)
2.5 KV AC, 50Hz/60Hz for 1
minute; Switch connection & C.T.
Terminal to ground.
CCU output 0.5 Kv Ac
50Hz / 60Hz for 1 minute
M20 - 3Nos

S1 & S2: 3C to 90C (630C)Fixed


S3 to S5: 80C to 400C Adjustable.
2.50C of Set Value
Available / 4-20mA / RS - 485
Up to 25 Mtrs.
Available
Press Fit Wago Type
IP 55(IEC-60529)
2.5 KV AC, 50Hz/60Hz for 1
minute; Switch connection & C.T.
Terminal to ground.
CCU output 0.5 Kv Ac
50Hz / 60Hz for 1 minute
M20 - 3Nos

Cable Gland

Optional

Optional

Thermometer Pocket

Optional

Optional

Dial Size
Dial angular Sweep
Dial Graduation
Accuracy Class
Max.No. of Switches
Switching Range
Contact Rating
Switch Differential
Switching Accuracy
Remote indicator
Max. Capillary Length
Switch Test Knob
Electrical Connection
Degree of Protection
High Voltage Test

Remote indicator 96 Sq

SPECIFICATIONs
Type

4 digits, 0.5 Seven Segments LEDs

Auxillary Supply

90 260V AC/DC

Resolution

0.10C

Degree of protection of enclosure

IP 20

Operating Temperature Range

00C to 600C

Signal output

4 sets of 4 - 20mA DC
Optional RS 485

Cutout dimension

92 Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Cold and Dry Test :


-40C to +70C

3.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

4.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

5.

Micro Switch rating Test :


a) ML - 1005H:
3A @ 250V AC &
3A @ 250V DC

b) ML - 1005AH:
15A @250V AC &
0.5A @250V DC

Ordering Information
Model
Type of Instrument
Range

No. of Switches

Switch Configuration
Capillary Length
Union Type

CCU Output for


indication / Scada
If WTI please
specify

1005H/1005AH
OTI / WTI
R1. 0 - 150C
R2. 0 - 160C
R3. 30 - 150C
R4. -20 to140C
(other ranges on request)
S2 - 2switches
S3 - 3switches
S4 - 4switches
S5 - 5switches
L - Normally open contact
L2 - Changeover contact
C1 - 1mts
C2 - 2mts....... upto C25 - 25mts
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
RI - Remote indicator - T1/T2/T3/T4 (for types, Refer Drawing)
PSU - External power supply with 2 Nos. of 4-20mA output
Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)

Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1005AH\OTI\R4\S4\L\C6\U4\RI-T2 ........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1005HX / 1005AHX


DIAL TYPE THERMOMETER

Duplex Hybrid OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Embedded Duplex PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a
master indication.
Current Converter Units (CCUs) are mounted inside the Local OTI/WTI, The output from which can be
connected to remote indicator and SCADA through external power supply units (PSUs).
For the WTIs additional Winding temperature simulator is provided
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches
ML: 1005 HX/1005 AHX

Specifications
Temperature Range

Model : 1005HX
0-1500C, 0-1600C, 30-1500C,
-20 to 1400C
150mm (6) Round
2700
10C
1% of FSD
5
15% - 85%

Model : 1005AHX
0-1500C, 0-1600C, 30-1500C,
-20 to1400C
150mm (6) Round
2700
10C
1% of FSD
5
15% - 85%

3A @ 250V AC/DC
Magnetic Blowout Micro switch

15A @ 250V AC
0.5A @ 250V DC
Standard Micro switch

Electrical entry

S1 & S2: 3C to 9C (630C) Fixed


S3 to S5: 8C to 400C Adjustable.
2.5 0C of Set Value
Available / 4-20mA / RS - 485
Up to 25 Mtrs.
Available
Press Fit Wago Type
IP 55(IEC-60529)
2.5 KV AC, 50Hz/60Hz for 1
minute; Switch connection & C.T.
Terminal to ground.
CCU output 0.5 Kv Ac
50Hz / 60Hz for 1 minute
M20 - 3Nos

S1 & S2: 3C to 90C (630C)Fixed


S3 to S5: 80C to 400C Adjustable.
2.50C of Set Value
Available / 4-20mA / RS - 485
Up to 25 Mtrs.
Available
Press Fit Wago Type
IP 55(IEC-60529)
2.5 KV AC, 50Hz/60Hz for 1
minute; Switch connection & C.T.
Terminal to ground.
CCU output 0.5 Kv Ac
50Hz / 60Hz for 1 minute
M20 - 3Nos

Cable Gland

Optional

Optional

Thermometer pocket

Optional

Optional

Dial Size
Dial angular Sweep
Dial Graduation
Accuracy Class
Max.No. of Switches
Switching Range
Contact Rating
Switch Differential

PSU

Switching Accuracy
Remote indicator
Max. Capillary Length
Switch Test Knob
Electrical Connection
Degree of Protection
High Voltage Test

Remote Indicator 96 Sq
Power Supply Unit - (PSU)

a.

Output Voltage: 24V

b.

Output Signal: Analogue output


2nos. 4-20mA DC
(Output - 1, Burden 250 Ohms)
(Output- 2, Burden 600 Ohms)

c.

Auxiliary supply: 90-260V AC/DC

REMOTE INDICATOR

a
b
d
e
f
g
h

Type : 4 digits, 0.5 Seven Segment LEDs


Auxiliary Supply : 90 260V AC/DC
Resolution : 0.10C
Degree of protection of enclosure : IP-20
Operating Temperature Range : 0C to 60C
Signal output: 4sets of 4-20mA DC, Optional
RS 485
Cutout Dimension: 92Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For

Ordering Information

1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Cold and Dry Test :


-40C to +70C

Model
Type of Instrument
Range

3.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

4.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

5.

Micro Switchrating Test :


a) ML - 1005HX:
3A @ 250V AC &
3A @ 250V DC

b) ML - 1005AHX:
15A @250V AC &
0.5A @250V DC

1005HX/1005AHX
OTI / WTI
R1. 0 - 150C
R2. 0 - 160C
R3. 30 - 150C
R4. -20 to140C
(other ranges on request)
No. of Switches
S2 - 2switches
S3 - 3switches
S4 - 4switches
S5 - 5switches
Switch Configuration L - Normally open contact
L2 - Changeover contact
Capillary Length
C1 - 1mts
C2 - 2mts....... upto C25 - 25mts
Union Type
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
CCU Output for
RI - Remote indicator - T1/T2/T3/T4 (For Types, Refer Drawing)
indication / Scada
(Connected through external powersupply PSUs)
If WTI please specify Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)
Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1005AHX\OTI\R4\S4\L\C6\U4\RI-T1........... Amps.............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1007

DIAL TYPE THERMOMETER

Standard OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches
ML : 1007
Specifications
Temperature Range
Dial Size
Dial angular Sweep
Dial Graduation
Accuracy Class
Max.No. of Switches
Switching Range
Contact Rating

Switch Differential
Switching Accuracy
Remote Repeater
Max. Capillary Length
Electrical Connection
Degree of Protection
High Voltage Test

PSU

Model : 1007
0-1500C, 0-1600C, 30-1500C,-20 to 1400C
115mm, Segment Dial
600
20C
1.5% of FSD
4
15% - 85%
15A @ 250V AC
0.5A @ 250V DC
Standard Micro switch
S1 & S2: 3C to 9C (630C) Fixed
S3 & S4: 8C to 400C Adjustable.
2.5 0C of Set Value
Available (Potentiometer Output)
Up to 25 Mtrs.
Press Fit Wago Type
IP 55 (IEC-60529)
2.5 KV AC, 50Hz/60Hz for 1 minute; all Terminals
to ground

Electrical entry

M20 - 3Nos

Cable Gland

Optional

Thermometer Pocket

Optional

Remote Repeater 96 Sq
Power Supply Unit - (PSU)

a.

Output Voltage: 24V

b.

Output Signal: Analogue output


2nos. 4-20mA DC
(Output - 1, Burden 250 Ohms)
(Output- 2, Burden 600 Ohms)

c.

Auxiliary supply: 90-260V AC/DC

REMOTE INDICATOR

a
b
d
e
f
g
h

Type : 4 digits, 0.5 Seven Segment LEDs


Auxiliary Supply : 90 260V AC/DC
Resolution : 0.10C
Degree of protection of enclosure : IP-20
Operating Temperature Range : 0C to 60C
Signal output: 4sets of 4-20mA DC, Optional
RS 485
Cutout Dimension: 92Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Cold and Dry Test :


-40C to +70C

3.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

4.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

5.

Micro Switch rating Test :


15A @250V AC &
0.5A @250V DC

Ordering Information
Model
Type of Instrument
Range

1007
OTI / WTI
R1. 0 - 150C
R2. 0 - 160C
R3. 30 - 150C
R4. -20 to140C
(other ranges on request)
No. of Switches
S2 - 2switches
S3 - 3switches
S4 - 4switches
Switch Configuration L - Normally open contact
L2 - Changeover contact
Capillary Length
C1 - 1mts
C2 - 2mts....... upto C25 - 25mts
Union Type
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
Repeater
Y - Requried,
N - Not Required
If WTI please specify Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)
Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1007\OTI\R3\S2\L2\C8\U5\Y\........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1007H
DIAL TYPE THERMOMETER

Hybrid OTI / WTI

General Features

The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and
does not require any trimming or other periodic adjustments.

Instruments are fully compensated for ambient temperature.

The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.

The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).

Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication.

Current Converter Unit (CCU) is mounted inside the Local OTI/WTI, The output from which can be connected to remote
indicator or SCADA are a combination of both.

For the WTIs additional Winding temperature simulator is provided

Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings
and are provided with projection mounting clamps.

A maximum pointer facility is provided, can be reset from outside.

All switch contacts are potential free micro switches

ML : 1007H

PSU

Specifications
Temperature Range
Dial Size
Dial angular Sweep
Dial Graduation
Accuracy Class

Model : 1007H
0-1500C, 0-1600C, 30-1500C,-20 to 1400C
115mm, Segment Dial
600
20C
1.5% of FSD

Max.No. of Switches
Switching Range
Contact Rating

4
15% - 85%
15A @ 250V AC
0.5A @ 250V DC
Standard Micro switch

Switch Differential

S1 & S2: 3C to 9C (630C) Fixed


S3 & S4: 8C to 400C Adjustable.

Switching Accuracy
Remote Indicator
Max. Capillary Length
Electrical Connection
Degree of Protection
High Voltage Test

Electrical entry

2.5 0C of Set Value


Available / 4-20mA / RS - 485
Up to 25 Mtrs
Press Fit Wago Type
IP 55(IEC-60529)
2.5 KV AC, 50Hz/60Hz for 1 minute; Switch
connection & C.T. Terminal to ground.
CCU output 0.5 Kv Ac
50Hz / 60Hz for 1 minute
M20 - 3Nos

Cable Gland

Optional

Thermometer Packet

Optional

Remote Repeater 96 Sq
Power Supply Unit - (PSU)

a.

Output Voltage: 24V

b.

Output Signal: Analogue output


2nos. 4-20mA DC
(Output - 1, Burden 250 Ohms)
(Output- 2, Burden 600 Ohms)

c.

Auxiliary supply: 90-260V AC/DC

REMOTE INDICATOR

a
b
d
e
f
g
h

Type : 4 digits, 0.5 Seven Segment LEDs


Auxiliary Supply : 90 260V AC/DC
Resolution : 0.10C
Degree of protection of enclosure : IP-20
Operating Temperature Range : 0C to 60C
Signal output: 4sets of 4-20mA DC, Optional
RS 485
Cutout Dimension: 92Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Cold and Dry Test :


-40C to +70C

3.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

4.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

5.

Micro Switch rating Test :


15A @250V AC &
0.5A @250V DC

Ordering Information
Model
Type of Instrument
Range

1007H
OTI / WTI
R1. 0 - 150C
R2. 0 - 160C
R3. 30 - 150C
R4. -20 to140C
(other ranges on request)
No. of Switches
S2 - 2switches
S3 - 3switches
S4 - 4switches
Switch Configuration L - Normally open contact
L2 - Changeover contact
Capillary Length
C1 - 1mts
C2 - 2mts....... upto C25 - 25mts
Union Type
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
CCU Output for
RI - Remote indicator - T1/T2/T3/T4 (For types, refer Drawing)
indication / Scada
PSU - External power supply with 2 Nos. of 4-20mA output
If WTI please specify Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)
Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1007H\OTI\R3\S2\L2\C8\U5\RI-T4........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1006

DIAL TYPE THERMOMETER

Standard OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches.
ML : 1006

Specifications

Model : 1006

Temperature Range

0-1500C, 0-2400C

Dial angular Sweep

2700

Dial Graduation

20C

Accuracy Class

1.5% of FSD

Max.No. of Switches

Switching Range

15% - 85%

Contact Rating

5A @ 250V AC,
0.5A @ 220V DC

Switch Differential

10C to 50C (30C20C) Fixed

Switching Accuracy

2.50C of Set Value

Max. Capillary Length

Up to 6 Mtrs.

Switch Test Knob

Available

Electrical Connection

1Sq mm. Copper Cable, 1mtr Length

Degree of Protection

IP 55(IEC-60529)

High Voltage Test

2.5 KV AC, 50Hz / 60Hz for 1 minute ; all Terminal to ground

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1. Protection class :
IP55 as per IEC 60529 CAT 2.
2. Vibration Test :
Amplitude 1mm,
frequency 50Hz, 1Hr / X,Y,Z axis
3. Salt Spray Test :
For polyster powder coating
and SS 304 Armour for 500 Hrs
as per DIN 50021Standard
4. Micro Switch rating Test :
5A @ 250V AC,
0.5A @ 220V DC

Ordering Information
Model
Type of Instrument
Range

1006
OTI / WTI
R1. 0 - 150C.
R2. 0 - 240C
No. of Switches
S2 - 2switches
Switch Configuration L - Normally open contact
L2 - Changeover contact
Capillary Length
C1 - 1mts
C2 - 2mts....... upto C6 - 6mts
Union Type
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1 BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
If WTI please specify Transformer CT Secondary output
..................(1A to 5A)
Simulated Temperature rise over top oil
........... (5C to 30C)
Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1006\WTI\R1\S2\L2\C5\U5 ........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1006H

DIAL TYPE THERMOMETER

Hybrid OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication.

Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches.
ML : 1006H

Specifications

Model : 1006H

Temperature Range

0-1500C, 0-2400C

Dial angular Sweep

2700

Dial Graduation

20C

Accuracy Class

1.5% of FSD

Max.No. of Switches

Switching Range

15% - 85%
5A @ 250V AC,

Contact Rating

ML : 2220-R2 (CCU)

0.5A @ 220V DC

Switch Differential

10C to 50C (30C20C) Fixed

Switching Accuracy

2.50C of Set Value

Remote Indicator

Availbale

Max. Capillary Length

Up to 6 Mtrs.

Switch Test Knob

Available

Electrical Connection

1Sq mm. Copper Cable, 1mtr Length

Degree of Protection

IP 55(IEC-60529)

High Voltage Test Test Voltage

Terminals Details

(a) Local OTI / WTI 2.5 KV AC, 50Hz / 60Hz

Switch connection / CT Connection

(b) Local OTI / WTI 500 V AC, 50Hz / 60Hz

Pt 100 sensor output

(c) CCU

500 V AC, 50Hz / 60Hz

Pt 100 sensor input +4-20mA Output

(d) CCU

2.5 KV AC, 50Hz / 60Hz

CT connection with power supply

Remote Indicator 96 Sq
SPECIFICATION
Type

4 digits, 0.5 Seven Segments LEDs

Auxillary Supply

90 260V AC/DC

Resolution

0.10C

Degree of protection of enclosure

IP 20

Operating Temperature Range

00C to 600C

Signal output

4 sets of 4 - 20mA DC, Optional RS 485

Cutout dimension

92 Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

3.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

4.

Micro Switch rating Test :


5A @ 250V AC,

0.5A @ 220V DC

Ordering Information
Model
Type of Instrument
Range

1006H
OTI / WTI
R1. 0 - 150C.

R2. 0 - 240C
No. of Switches
S2 - 2switches
Switch Configuration L - Normally open contact
L2 - Changeover contact
Capillary Length
C1 - 1mts
C2 - 2mts....... upto C6 - 6mts
Union Type
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1 BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
If WTI please specify Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)
Note: 1) WTI Gradient is factory set. If required customer can adjust as per requirment.

2) External CCU and Remote Indicator is Part of the scheme.
Sample Ordering Information :1006H\WTI\R1\S2\L\C3\U2 ........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1006DH

DIAL TYPE THERMOMETER for


DRY TYPE TRANSFORMER

Winding temperatures Indicator & Controller for Dry Type Transformers / Cast-Resin Transformers with built-in
RTD scheme for Independent Remote indication and 4-20mA DC output for SCADA connection.

Hybrid Instrument
This is a high performance temperature Monitoring instrument with built-in PT-100 Sensor (RTD) & Current
Converter Unit and external Remote indicator with built-in power supply unit

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches
ML : 1006DH

Specifications

Model : 1006DH

Temperature Range

0-2400C

Dial angular Sweep

2700

Dial Graduation

20C

Accuracy Class

1.5% of FSD

Max.No. of Switches

Switching Range

15% - 85%

Contact Rating

5A @ 250V AC,
0.5A @ 220V DC

Switch Differential

10C to 50C (30C20C) Fixed

Switching Accuracy

40C of Set Value

Remote Indicator

Availbale

Max. Capillary Length

Up to 6 mtrs

Electrical Connection

1Sq mm. Copper Cable, 1mtr Length

Degree of Protection

IP 55 (IEC-60529)

High Voltage Test

Switch Contact - 2.5KV AC,50Hz/60Hz for 1 Minute


between Switch Terminals to ground
CCU- 500V AC,50Hz/60Hz for 1 Minute between CCU
Terminals to ground

Power Supply Unit


PSU

Signal out put

2 nos 4-20 mA DC

Aux Supply voltage

90-260V AC/DC

Burden on signal output

600 max including loop resistance

Temperature range

0-240C

Degree of protection

IP-40

Digital Remote indicator


Remote Indicator 96 Sq

Temperature range

0-240C

Signal input

4-20 mA DC

Aux Supply voltage

90-260V AC/DC

Communication

RS-485MODBUS RTU Communication


(Optional)

Degree of protection

IP 20

Cutout Dimension

92 sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

3.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

4.

Micro Switch rating Test :


5A @ 250V AC,

0.5A @ 220V DC

Ordering Information
Model
Type of Instrument
Range
No. of Switches
Switch Configuration
Capillary Length

1006DH
WTI
R1. 0 - 240C
S2 - 2switches
L - Normally open contact
L2 - Changeover contact
C1 - 1mts
C2 - 2mts....... upto C6 - 6mts

Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1006DH\WTI\R1\S2\L\C4

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1006HX
DIAL TYPE THERMOMETER

Duplex Hybrid OTI / WTI

General Features

The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Embedded Duplex PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a
master indication.
This output can be connected to Remote Indicator or SCADA or combination of both.
WTI additional Winding temperature simulator is provided.
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches.

ML : 1006HX

Specifications

Model : 1006HX

Temperature Range

0-1500C, 0-2400C

Dial angular Sweep

2700

Dial Graduation

20C

Accuracy Class

1.5% of FSD

Max.No. of Switches

Switching Range

15% - 85%
5A @ 250V AC,

Contact Rating

PSU

0.5A @ 220V DC

Switch Differential

10C to 50C (30C20C) Fixed

Switching Accuracy

2.50C of Set Value

Remote Indicator

Availbale

Max. Capillary Length

Up to 6 Mtrs.

Switch Test Knob

Available

Electrical Connection

1Sq mm. Copper Cable, 1mtr length

Degree of Protection

IP 55(IEC-60529)

High Voltage Test

Test Voltage

Terminals Details

(a) Local OTI / WTI

2.5 KV AC, 50Hz / 60Hz

Switch connection / CT Connection

(b) Local OTI / WTI

500 V AC, 50Hz / 60Hz

Pt 100 sensor output

(c) CCU

500 V AC, 50Hz / 60Hz

Pt 100 sensor input +4-20mA Output

(d) CCU

2.5 KV AC, 50Hz / 60Hz

CT connection with power supply

Power Supply Unit - (PSU)

a.

Output Voltage: 24V

b.

Output Signal: Analogue output


2nos. 4-20mA DC
(Maximum burden 600 Ohms
Including Loop resistantance)

c.

Auxiliary supply: 90-260V AC/DC

Remote Indicator 96 Sq

REMOTE INDICATOR

a
b
d
e
f
g
h

Type : 4 digits, 0.5 Seven Segment LEDs


Auxiliary Supply : 90 260V AC/DC
Resolution : 0.10C
Degree of protection of enclosure : IP-20
Operating Temperature Range : 0C to 60C
Signal output: 4sets of 4-20mA DC, Optional
RS 485
Cutout Dimension: 92Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

3.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

4.

Micro Switch rating Test :


a) ML - 1006HX:
5A @ 250V AC,

0.5A @ 220V DC

Ordering Information
Model
Type of Instrument
Range

1006HX
OTI / WTI
R1. 0 - 150C.

R2. 0 - 240C
No. of Switches
S2 - 2switches
Switch Configuration L - Normally open contact
L2 - Changeover contact
Capillary Length
C1 - 1mts
C2 - 2mts....... upto C6 - 6mts
Union Type
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1 BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
CCU Output for
RI - Remote indicator - T1/T2/T3/T4 (For types, Refer Drawing
indication / Scada
(Connected through external powersupply PSUs)
If WTI please specify Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)
Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1006HX\OTI\R2\S2\L\C4\U1\RI-T3 ........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1031

DIAL TYPE THERMOMETER

Standard OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti
vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches.
ML : 1031

Specifications

Model : 1031

Temperature Range

0-1500C

Dial size

115mm, Segment Dial

Dial angular Sweep

600

Dial Graduation

20C

Accuracy Class

1.5% of FSD

Max.No. of Switches

Switching Range

15% - 85%

Contact Rating

5A @ 250V AC
0.5A @ 220V DC

Switch Differential

10C to 50C (30C20C) Fixed

Switching Accuracy

2.50C of Set Value

Max. Capillary Length

Up to 6 Mtrs.

Electrical Connection

1Sq mm. Copper Cable, 1mtr Length

Degree of Protection

IP 55(IEC-60529)

High Voltage Test

2.5KV AC, 50Hz/60Hz for 1 minute; All terminal to ground

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For

Ordering Information

1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

3.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

4.

Micro Switch rating Test :


5A @ 250V AC,

0.5A @ 220V DC

Model
Type of Instrument
Range
No. of Switches
Switch Configuration
Capillary Length
Union Type

If WTI please specify

1031
OTI / WTI
R1. 0 - 150C.
S2 - 2switches
L - Normally open contact
L2 - Changeover contact
C1 - 1mts
C2 - 2mts....... upto C6 - 6mts
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1 BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
Transformer CT Secondary output
..................(1A to 5A)
Simulated Temperature rise over top oil
........... (5C to 30C)

Note: WTI Gradient is factory set. If required customer can adjust as per requirment.
Sample Ordering Information :1031\OTI\R1\S2\L2\C6\U2 ........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MODEL - 1031H

DIAL TYPE THERMOMETER

Hybrid OTI / WTI

General Features
The fully sealed liquid expansion in the system provides a self powered indication and operation to the
instruments, and does not require any trimming or other periodic adjustments.
Instruments are fully compensated for ambient temperature.
The WTI instruments have a built in Thermal imaging system for transformers hot spot indication.
The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A).
Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication.

Instrument cases are aluminium die casted and polyester powder coated. Each instrument has
anti vibration mountings and are provided with projection mounting clamps.
A maximum pointer facility is provided, can be reset from outside.
All switch contacts are potential free micro switches.

ML : 1031H

Specifications

Model : 1031H

Temperature Range

0-1500C

Dial Size

115mm, Segment Dial

Dial angular Sweep

600

Dial Graduation

20C

Accuracy Class

1.5% of FSD

Max.No. of Switches

Switching Range

15% - 85%
5A @ 250V AC,

Contact Rating

ML : 2220-R2 (CCU)

0.5A @ 220V DC

Switch Differential

10C to 50C (30C20C) Fixed

Switching Accuracy

2.50C of Set Value

Remote Indicator

Availbale

Max. Capillary Length

Up to 6 Mtrs.

Electrical Connection

1Sq mm. Copper Cable, 1mtr Lenght

Degree of Protection

IP 55(IEC-60529)

High Voltage Test

Test Voltage

Terminals Details

(a) Local OTI / WTI

2.5 KV AC, 50Hz / 60Hz

Switch connection / CT Connection

(b) Local OTI / WTI

500 V AC, 50Hz / 60Hz

Pt 100 sensor output

(c) CCU

500 V AC, 50Hz / 60Hz

Pt 100 sensor input +4-20mA Output

(d) CCU

2.5 KV AC, 50Hz / 60Hz

CT connection with power supply

SPECIFICATIONs

Remote Indicator

Type

4 digits, 0.5 Seven Segments LEDs

Auxillary Supply

90 260V AC/DC

Resolution

0.10C

Degree of protection of enclosure

IP 20

Operating Temperature Range

00C to 600C

Signal output

4 sets of 4 - 20mA DC, Optional RS 485

Cutout dimension

92 Sq.mm

www.precimeasure.com

DIAL TYPE

Precimeasure

Type Tested For


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

3.

Salt Spray Test :


For polyster powder coating and
SS 304 Armour for 500 Hrs as per
DIN 50021 Standard

4.

Micro Switch rating Test :


5A @ 250V AC,

0.5A @ 220V DC

Ordering Information
Model
Type of Instrument
Range
No. of Switches
Switch Configuration
Capillary Length
Union Type

If WTI please specify

1031H
OTI / WTI
R1. 0 - 150C.
S2 - 2switches
L - Normally open contact
L2 - Changeover contact
C1 - 1mts
C2 - 2mts....... upto C6 - 6mts
U1 - 1/2 BSP Male
U2 - 3/4 BSP Male
U3 - 1 BSP Male
U4 - 1/2 BSP Female
U5 - 3/4 BSP Female
Transformer CT Secondary output..................(1A to 5A)
Simulated Temperature rise over top oil........... (5C to 30C)

Note: 1) WTI Gradient is factory set. If required customer can adjust as per requirment.

2) External CCU and Remote Indicator is Part of the scheme.

Sample Ordering Information :1031H\WTI\R1\S2\L\C3\U2 ........... Amps ...............C

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

Precimeasure

DIAL TYPE BI - METALLIC


THERMOMETER

BI-METALLIC

Bi-metallic type thermometer consists of Helical Bimetal Coil, which will expand or contract according to the
temperature changes, which in turn operates indicating pointer.

General Features
a
a
a
a
a

No external power supply required for indication or operation.


Sealed system which requires no trimming or periodic site adjustments
Directly mounted on the Transformer & Other Process Control Equipments.
A maximum pointer facility is provided, can be reset from outside.
The instruments are capable of working at an ambient temperature range of 00C to +600C.
ML :1070

Model 1070 (Thermometer Without Contact, Top Mounting)

SPECIFICATIONs
Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Segment Dial
1050
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division
PDC Aluminum Casting with Polyester Powder Coated.

Model 1071 (Thermometer With 2 Contact, Top Mounting)

SPECIFICATIONs
Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Segment Dial
1050
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division
PDC Aluminum Casting with Polyester Powder Coated.

Max. Number of Switches


Switch Type
Switch Rating
Switches
Adjustable Range
Accuracy of switch setting
Switch Differential Range
Contact Type
Cable Gland (Polyamide / Brass)
High Voltage Test

ML :1071

2
Micro Switch
5A at 240V AC
Normally Open Type or Changeover Type
200C 1050C
40C of Set Value
60C30C
Potential Free
Cable Gland Size PG16
2KV AC, 50/60 Hz for 1 Minute, All terminals to ground

www.precimeasure.com

* The WTI instruments have a built in Thermal imaging system for transformers hot
spot indication.
* WTI Gradient calibration is factory set as per customer specification. If required, a
provision is made for small adjustment at site.

Model 1071 WTI (Thermometer With 2 Contact, Top Mounting)


Winding Temperature Indicator :
SPECIFICATIONs

ML :1071-WTI

Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Segment Dial
1050
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division
PDC Aluminum Casting with Polyester Powder Coated

Max. Number of Switches


Switch Type
Switch Rating
Switches
Adjustable Range
Switching Accuracy
Switch Differential
Contact Type
Cable Gland (Polyamide / Brass)
High Voltage Test

2
Micro Switch
5A at 240V AC
Normally Open Type or Changeover Type
200C 1050C
40C of Set Value
60C30C
Potential Free
Cable Gland Size PG11-2Nos
2KV AC, 50Hz for 1 Minute, All terminals to ground

ML :1068
Model 1068 (4" Dial Thermometer With 2 Contact, Horizontal Mounting)

SPECIFICATIONs
Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Round Dial 4
1350
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division
PDC Aluminum Casting with Polyester Powder Coated

Max. Number of Switches


Switch Type
Switch Rating
Switches
Adjustable Range
Accuracy of switch setting
Switch Differential Range
Contact Type
Cable Gland (Polyamide / Brass)
High Voltage Test

2
Micro Switch
5A at 240V AC
Normally Open Type or Changeover Type
400C 1050C
40C of Set Value
60C30C
Potential Free
Cable Gland Size PG16
2KV AC, 50/60 Hz for 1 Minute, All terminals to ground

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

Precimeasure

ML :1075

Model 1075 (3 Dial Horiozontal Mounting with


Maximum Pointer)
Specifications
Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Round Dial 3
2400
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division
SS-304 Case (Natural Finish).

ML :1073 / 1074

Model 1073 (4 Dial Top Mounting with Maximum Pointer)


Specifications
Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Round Dial 4
2400
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division
SS-304 Case (Natural Finish)

Model 1074 (6 Dial Top Mounting with Maximum Pointer)


Specifications

Dial
Angular Sweep
Range
Graduation

Round Dial 6
2400
0-1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division

Instrument Case

SS-304 Case (Natural Finish).

Accuracy

www.precimeasure.com

BI-METALLIC

DIAL TYPE BI - METALLIC


THERMOMETER

ML :1078

Model 1078 (3 Dial Top Mounting with Maximum Pointer)


Specifications
Dial
Angular Sweep
Range
Accuracy
Graduation

Round Dial 3
2400
0 -1200C (Other ranges on request)
40C Between 400C & 1100C
20C per division

Instrument Case

SS-304 Case (Natural Finish).

ML :1079

Model 1079 (3 Dial Entry at Angle 450 with Maximum Pointer)


Specifications
Dial
Angular Sweep
Range
Accuracy
Graduation
Instrument Case

Round Dial 3
2400
0 -1200C ( Other ranges on request)
40C Between 400C & 1100C
20C per division
SS-304 Case (Natural Finish).

All the Models Type Tested For :


1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Salt Spray Test :


Model-1068 / 1070 / 1071
For polyster powder coating
500 Hrs as per DIN 50021Standard

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

Precimeasure

Electronic Temperature
Controllers

MODEL 2241B & 2242 WINDING TEMPERATURE INDICATOR / CONTROLLER FOR DRY TYPE TRANSFORMERS
APPLICATION :
MODEL 2241B/2242/2244T3 is designed for monitoring the temperatures of L.V. windings of the Dry-Type Transformer / Cast Resin
Transformers. It will display winding temperatures and take necessary control action as per set and differential values programmed
by the user. The protection system also records maximum temperatures and will display the same along with corresponding channel
number whenever relevant push button is pressed.

SALIENT FEATURES :

Power line filter with Fuse is incorporated in the input of the power supply to protect the equipment from High Energy Surge
and Electrical Fast Transient.
High Scanning Speed
Remote Indication & Data Acquisition facility with burden upto 600 ohms.
Optional RS-485 MODBUS RTU Communication
Specifications
Temperature Sensor
input
No. of Sensor inputs
No. of Set-points

ML :2241B

Model 2241B
RTD (Pt-100 DIN 43760)

Model 2242
K Type thermocouples

Three
Four (Alarm, Trip, Fan1,
Fan2)
00C 2500C
Range
00C -3000C
10C
Resolution
0.10C
0
0.8%, one count under
Accuracy
1 C
normal conditions.
Display Speed
User Settable (1-99 Seconds)
5 Seconds
Display
Six Nos. 0.5 Seven Segment LEDs Four nos 0.5 Seven Segment LEDs
Auxiliary Supply Voltage 90-260 V AC/DC
0-20V AC or 0-240V AC
Output
Analogue output DC 4-20mA
Analogue O/P DC
(Maximum burden 600 Ohms)
0-1mA (10000 Ohms)
4-20mA(600 Ohms
burden)
Communication
Isolated RS-485 MODBUS RTU
RS-485 & RS-232
Communication (Optional).
Communication
Contact Rating @
5A @ 220 VAC / 5A @ 30 DC
Alarm & Trip 10A@120
Resistive Load
VAC & 8A@240 VAC, Fan1
& Fan2 30A@120/240VAC
Power Consumption
5 Watts
8 Watts
Weight
2Kgs. Approx without packing box 2kgs Approx. without
packing box
Enclosure
Aluminium Pressure Diecasting
Panel Mount thru Cutout
enclosure, powder coated all sides Indoor Mounting only
with acrylic viewing window, IP-55
Temp : -300C to 550C
Operating conditions
Temp:-300C to 700C

ML :2242

Four, Eight & Twelve


Three (Fan, Alarm and Trip)

Type Tested For


Model: 2241B

Model: 2242

1.

Cold and Dry Test :


-30C to +70C

1.

2.

Vibration Test :
2.
Amplitude 1mm,
frequency 50Hz, 1Hr / X,Y,Z axis

Shock Test :
11ms/15g Procedure as per the
IS: 13779 (12 shots)
Vibration Test :
Amplitude 0.5mm,
Frequency 05 to 50Hz,
02 sweeps / X,Y,Z axis

www.precimeasure.com

ELECTRONIC

a
a
a

Electronic Temperature
Controllers
MODEL 2244T3 & 2253 WINDING TEMPERATURE INDICATOR / CONTROLLER FOR DRY TYPE TRANSFORMERS
APPLICATION :
MODEL 2244T3 & 2253 is designed for monitoring the temperatures of L.V. windings of the Dry-Type Transformer / Cast Resin
Transformers. It will display winding temperatures and take necessary control action as per set and differential values programmed
by the user. The protection system also records maximum temperatures and will display the same along with corresponding
channel number whenever relevant push button is pressed.

SALIENT FEATURES :

Power line filter with Fuse is incorporated in the input of the power supply to protect the equipment from High Energy Surge
and Electrical Fast Transient.

a
a
a

High Scanning Speed


Remote Indication & Data Acquisition facility with burden upto 600 ohms.
Optional RS-485 MODBUS RTU Communication

ML : 2244T3

specifications
Temperature Sensor input
No. of Sensor inputs
No. of Set-points
Range
Resolution
Accuracy
Display Speed
Display
Auxiliary Supply Voltage
Output
Communication
Contact Rating @ Resistive Load
Power Consumption
Weight
Enclosure
Operating conditions

specifications
Temperature Sensor input
No. of Sensor inputs
No. of Set-points
Range
Resolution
Accuracy
Display Speed
Display
Auxiliary Supply Voltage
Output
Communication
Contact Rating @ Resistive Load
Power Consumption
Weight
Enclosure
Operating conditions

RTD (PT-100 DIN 43760)


one
Two (Alarm,Trip)
00C 2000C (Other Ranges on Request)
10C
1%
Three nos 0.5 Seven Segment LEDs
90-260V AC/DC (Other voltages on Request)
Analogue output DC 4-20mA (Maximum burden 600 Ohms)
5A@220 VAC / 5A@30 VDC
2 Watts
0.5kgs Approx. without packing box.
96 Sq mm ABS Box Enclosure Panel Mount through Cutout,
IP-20
Temp : 00C to 600C

RTD (PT-100 DIN 43760)


Four
Three (Fan, Alarm and Trip)
-20 to+3000C / 0 - 3000C
10C
20C
User Settable (1- 30 Seconds)
4 Nos. 0.5 Seven Segment LEDs
90-260 V AC/DC
Analogue output DC 4-20mA (Maximum burden 600 Ohms)
RS-485 MODBUS RTU Communication (Optional)
5A @ 220 VAC / 5A @ 30 VDC
5 Watts
0.5Kgs Approx without packing
96 Sq mm ABS Box Enclosure Panel Mount through Cutout,
IP-20
Temp: 00C to 600C

ML : 2253

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

Electronic Temperature
Controllers

Precimeasure

MODEL 2243A OTI / WTI TEMPERATURE INDICATOR / CONTROLLER


APPLICATION :
This scheme is used to Indicate Oil & Winding Temperature of the oil immersed transformers. Relays are provided for Alarm, Trip
and Cooler Duties, are operated as per the set value. 4-20mA DC signal outputs are provided separately for OTI & WTI for Remote
Indication or SCADA Purpose. The System has the facility to store the maximum temperature attained.

SCHEME CONSISTS OF :

1. PT -100 Sensor 1 No. 2. Electronic Temperature Controller 1 No. 3. Thermometer Pocket 1 No. (Optional)

ML : 2243A

Description
Temperature Sensor input
No. of sensor inputs
CT Sec Current Input
Temperature Rise
No. of Set-points OTI
No. of Set-points WTI
Contact Rating
Range
Resolution
Accuracy
Display
Auxiliary Supply Voltage
Signal Outputs

Type Tested For


1.

Cold and Dry Test :


-30C to +70C

Power Consumption
Weight
Enclosure

2.

Vibration Test :
Amplitude 1mm,
frequency 50Hz, 1Hr / X,Y,Z axis

Communication
Operating Temperature

Model: 2243A

MODEL 2246 TAP Position Indicator


SPECIFICATIONs

Model 2246

Signal Input
Range
Display
Auxiliary Supply Voltage
Out put

Resistance (1Kohms per step)


1-39 Position (User settable)
3 nos. 0.5 7 Segment Leds
90-260 V AC/DC
Four sets of 4-20 mA DC ( Maximum
Burndon 600 Ohms)
RS - 485 Modbus RTU Communication
(Optional)
5 Watts (Max.)
0.5Kgs Approx. without packing
96 sq mm ABS Box Enclousure Panel
Mount through cutout IP-20
00C to 600C

Communication
Power Consumption
Weight
Enclosure
Operating Temperature

Details
RTD (Pt 100 DIN 43760)
ONE
1.0A to 5.0A (User Selectable)
10C to 450C (User Selectable)
Two Relays for Alarm and Trip (1C/O SPDT Relay
contacts)
Four Relays for Alarm, Trip, Fan 1 and Fan 2
(1C/O SPDT Relay contacts)
5A @ 220 VAC / 5A @ 30 VDC Resistive Load
0-1500C
0.10C
10C
0.5 Seven Segment LED Display
90-260 V AC/DC
Two analogue Outputs (4-20mA Suitable for 600
Ohms Burdon) Each 1 No.
5 Watts (Max.)
2 Kgs Approx. without packing
Aluminium Pressure Die Casting enclosure,
powder coated with acrylic viewing window, IP-55
RS-485 MODBUS RTU (Optional)
-300C to 700C

ML : 2246

www.precimeasure.com

ELECTRONIC

SPECIFICATION :

Electronic Temperature
Controllers
ELECTRONIC TYPE
MODEL 2220-R1 & 2220-R2 TEMPERATURE INDICATOR
APPLICATION : PRECIMEASURE Electronic Instruments are designed to indicate
the Top Oil Temperature / Winding Temperature of the oil-immersed transformers
in remote control room. This scheme has 2 Nos of 4-20 mA DC Signal outputs
proportional to the temperature range. Signal OUTPUT 1 is connected to an
indicator for indicating temperature at remote and OUTPUT 2 can be connected
to Recorder or Data Acquisition System.

SCHEME CONSISTS OF :

1.

PT -100 Sensor 1 No.

2.

Current Converter Unit 1 No.

3.

Remote Indicator 1 No.

4.

Thermometer Pocket 1 No. (Optional)

SPECIFICATIONs :
SL.
1
a.
b.
2

Description

Model 2220 R1

Model 2220 R2

PT 100 SENSOR ASSEMBLY


Element : Simplex, 3 wire system / Duplex, 6 Wire System
Tolerance : DIN 43760, Class B

CURRENT CONVERTER UNIT WITH POWER SUPPLY UNIT

IP-55
Aluminium Casting.

IP-40
ABS, DIN Enclosure Box.

a
b
c
d
e
f
g

Signal Input : PT 100 RTD, Simplex 3 wire


Auxiliary Supply : 90 260V AC/DC
Signal Outputs : 4 20mA DC corresponding to temperature range
Burden on Output Signal : 600 Ohms maximum including loop resistance
Accuracy of Signal Output : 1% of F.S.D.
Degree of protection of enclosure
Casing
3
REMOTE INDICATOR
a
Type : 4 digits, 0.5 Seven Segment LEDs
b
Auxiliary Supply : 90 260V AC/DC
c
Temperature indicator range : 0-1500C (Other ranges on request)
d
Resolution : 0.10C
e
Degree of protection of enclosure : IP-20

Type Tested For


Model: 2220-R1& 2220-R2
1. 2220-R1, Protection class :
IP55 as per IEC 60529 CAT 2.
2. 2220-R2, Protection class:
IP40 as per IEC 60529 CAT 2
3.Cold and Dry Teast :
-30C to +70C
4.Vibration Test :
Amplitude 1mm, frequency
50Hz,1Hr / X,Y,Z axis

5. EMI / EMC Test :


a) Electrostatic Discharge
Immunity Test as per
IEC61000-4-2, 2001
b) Electrical Fast Transient
Immunity Test as per
IEC61000-4-4, 2004
c) High Energy Surge
Immunity Test as per
IEC61000-45, 2005

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

MAGNETIC OIL LEVEL


GUAGE

Precimeasure
Model 1080 - 4" & 6"

APPLICATION:
Magnetic Oil Level Gauge (MOG) is used to Measure Oil Level of oil filled Transformers & Oil filled Tanks.
SPECIFICATIONS :
Liquid in Tank

Transformer oil to IS 335 and or any other Oil

Working Temperature

-30 to 100C of oil

Working Pressure

0 to 4 Kg / Cm2

Working Environment

Indoor or Outdoor

INDICATION :
Dial size

4" & 6" Round


Color Black marking on white background or
any other combination as required. Standard
Red Line Indication for Min. to Empty Level

Angular Sweep

300

FLOAT (SENSOR) AND ARM :


Material

Float :Polyurethane Foam/Brass


Float Arm : Brass

Float-Arm Length

Fixed Length as given by Customer

Travel

Max. 45 Below & Above from the centre

Margin

Leave Min. 40 mm beyond lower & higher


limit markings to avoid striking of float to
bottom & top of conservator.

Type

Micro switch

Contact Rating

5A @ 240V AC, 0.25A 220V DC

Type Tested For

OTHERS

SWITCH :

Ordering Information

1.

Protection class :
IP55 as per IEC 60529 CAT 2.

Model No

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

Conservator Diameter

1080/4

Float Arm Length


Mounting Vertical/Inclined
If Inclined Mention Angle
And other Specifications if any

MODEL: 1090
SIZE: 1 B.S.P MALE

PRESSURE RELIEF DEVICE

Application:
PRD is a safety device for the distribution transformer up to 5000KVA, OLTC and other similar
equipments. This PRD is used to prevent heavy damages of the tank in case of sudden rise of
internal pressure.

operating Pressure :
Operating Pressure range available from 0.2 to 0.7 kg/sq.cm with tolerance
0.05 kg/sq.cm.

General Features




Safe spring loaded design that does not require external power supply for operation
Positive downward directional flow limits horizontal spraying of hot oil on adjacent equipment
Large diameter top cover with improved operating force providing better protection
Transport safety clip to prevent oil spillage during transportation of oil filled transformers
Available in brass or Zamak body construction

www.precimeasure.com

BEARING / AIR
TEMPERATURE INDICATOR /
CONTROLLER

Precimeasure
Model 1006 - BTD/ATD
APPLICATION :

This Instruments is used for monitoring and controlling the Bearing/ Air Temperature of the Motor and Generators

Type Tested For

SPECIFICATIONS :
Temperature Range

0-150C (Other Ranges


on request)

Dial Size

150mm (6") Round

Dial Angular Sweep

270

Dial Graduations

2C per Division

Accuracy Class

1.5% of F.S.D

Max. No. of Switches

Switch Setting

15% to 85%

Switch Contact Rating

5A at 250 V AC & 0.5A


at 220V DC

Switch Differential

3 C 2 C (Fixed)

Accuracy of Switch Setting

2.5C of Set Value

Max. Capillary Length

Up to 15 Meters

Mounting

Flush / Projection

1.

Protection class :
IP55 as per IEC 60529 CAT 2.

2.

Vibration Test :
Amplitude 1mm, frequency 50Hz,
1Hr / X,Y,Z axis

3.

Micro Switch rating Test :

5A @ 250V AC &
0.5A @ 220V DC

PORTABLE OIL BATH


Model HOB -180

For OTI & WTI Caliberation

Display Specification
Range

Ambient +5C To 180C

Display

Dual 4 Digit Display

Disply Resolution

0.1C

Temp-Setting

With Push Button Data Entry

General Specification
System Acuracy

Better Then 0.5% Of Reading Or 0.5%C


(Which Ever Is Higher)

Stability

Better Then 0.5%C

Set Point Archive Time

Approx. 30 Minutes

Stabilization Time

Approx. 20 Minutes After Reaching Set Value

Electrical Specification
Power Consumption

300 Watts Approx.

Power Supply

230Vac, 50Hz

Physical Specification
Dimensions

6 (W) X 14 (H) X 9(L)

Weight

5.5 Kgs Approx.

Heating Media

Silicon Oil / Transformer Oil

Oil Volume

1.5 Ltr Approx

Well Depth

160 mm

Accessories

Drain Locking O Ring

Stirring

By Mechanical Stirrer Of Ig Motor

Precimeasure Controls Pvt. Ltd.


Registered Office & Works :

Branch Office & Works :

Phone : + 91-80-4260 2705 / 08


Fax : + 91-80-4155 2205
E-Mail : salesbng@precimeasure.com

Phone : + 91-44-2250 0191 / 2250 0175


Fax : + 91-44-2250 0175
E-Mail : saleschn@precimeasure.com

No. 168/C Industrial Suburb,


Peenya 3rd Phase, Bangalore - 560058. India

No. 27,28,30, Block-II, 2nd Floor,


Sidco Electronics Complex, Guindy, Chennai - 600032. India

Western India Region Office :


Mobile : 09377561070
E-Mail : sanjay@precimeasure.com

www.precimeasure.com

SCHEME

Scheme drawing
Precimeasure

www.precimeasure.com

Scheme drawing
Precimeasure

www.precimeasure.com

Das könnte Ihnen auch gefallen