Sie sind auf Seite 1von 77

TOLCO Fire Protection Support Systems

Pipe Hangers
Supports
Seismic Bracing
UL Listed
FM Approved
for Fire Sprinkler
Installations

www.tolco.com
Revision 12/06/2007

Catalog Forward

Warning

This catalog has been created with an acute awareness of the field problems of the piping contractor.
We have sought and received input from engineers,
installers, field inspectors and others closely involved
with the installation of piping systems. This is where
needs are discovered, and where products and services are genuinely tested.

Pipe hanger products included in this catalog are


intended for installation and service only as described
herein.

TOLCO is proud to present a complete and versatile line of pipe hangers and related products. The
TOLCO line has been methodically developed to
effectively address support problems in the commercial and industrial piping fields.
A thorough knowledge of our customers needs and
problems was no less important than the development of our manufacturing skills in the emergency of
TOLCO as a leader in the pipe hanger industry. Our
people are equipped to respond quickly to your product and service needs on both standard items and
specialized metal fabrication.

We are aware that these products have been used


(often without incident) for purposes and in ways other
than those for which they were designed and manufactured. Examples of which are: use of products
as erection tools; use of beam clamps on a beam
not specified for them; use of concrete inserts as an
anchor for pulling pipe to proper elevation; suspension
of one clevis hanger under another resulting in cumulative load greater than specified capability. In such
cases of misapplication or improper use, we cannot
be held responsible for injuries or property damage.
TOLCO pipe hanger products are carefully designed
and manufactured to industry standards. Care should
be exercised by installers and end users to install, use
and maintain these products properly to avoid any
possible on-the-job accidents.

Custom Fabrication

Designs

We have expanded our manufacturing capacity in


response to the growing demand for customized
metal fabrication and special hangers. When some
detail of construction or piping arrangement makes it
necessary to deviate from standard types of hangers,
TOLCO is equipped to furnish hangers and supports
of any required type. These products combine proven
designs and standards with new innovations that
enhance their utility.

Product design and specifications are subject to


change without notice.

Approvals and Specifications


TOLCO, as a member of the American Pipe Fittings
Association, is cooperating with engineers and architects in the preparation of specifications covering
hanger requirements and the interpretation of applicable piping safety codes.
All TOLCO products are carefully manufactured
to meed the highest standards in the industry. All
products, as a minimum conform to Manufacturers
Standardization Society MSS-SP-58, and to the allowable stresses specified in the ANSI B31.1 code for
pressure piping.

Finishes
Most hangers are available in: stainless steel, electro-galvanized or hot-dipped galvanized. Other
special finishes are available upon request. Items
ordered hot-dip galvanized may be supplied with electro-galvanized threaded components unless otherwise
specified. If you require a finish not listed in the
product data of a specific hanger, please consult
our factory.

Index
Figure numbers in this catalog are in numerical order.

Terms and Conditions of Sale


For conditions and terms of sale, please consult our
current price guide.

Many TOLCO Products are also listed, approved or


conform to:
Underwriters Laboratories UL-203
Factory Mutual Engineering
National Fire Protection Association NFPA-13,
NFPA-13R, NFPA-13D and NFPA-24
Federal Specification WW-H-171EE

Main Office/Manufacturing Facility 1375 Sampson Ave. Corona, CA 92870 Ph: 951.737.5599 Fax: 951.737.0330
Customer Service 800.786.5266
www.tolco.com

www.tolco.com
Revision 6/9/2008

Index

Pipe Hangers and Straps

Fig. 1
Fig. 1F
Standard Clevis Hanger Standard Clevis Hanger
MSS-SP-69, Type 1
with Felt Lining
WW-H-171E, Type 1
Page 7
Page 5

Fig. 1CBS
Cross Bolt Spacer
Page 6

Fig. 2
Adjustable Band Hanger
MSS-SP-69, Type 10
WW-H-171E, Type 10
Page 8
Fig. 2NFPA
Trimline Band Hanger
with Reducer Rod Size
MSS-SP-69, Type 10
WW-H-171E, Type 10
Page 8

Fig. 24
Hanger for
CPVC Plastic Pipe,
Double Fastener Strap
Type Side Mount
Page 19

Fig. 200
Trimline Band Hanger
MSS-SP-69, Type 10
WW-H-171E, Type 10
Page 40

Fig. 1PVC
PVC Coated
Clevis Hanger
MSS-SP-69, Type 1
WW-H-171E, Type 1
Page 7

Fig. 3
J-Hanger for
Pipe or Conduit
MSS-SP-69, Type 5
Page 11

Fig. 22
Hanger for CPVC
Plastic Pipe
Single Fastener Type
Page 17

Fig. 2F
Adjustable Band Hanger
with Felt Lining
MSS-SP-69, Type 10
WW-H-171E, Type 10
Page 9

Fig. 3F
J-Hanger with Felt Lining
MSS-SP-69, Type 5
Page 11

Fig. 23
Hanger for CPVC
Plastic Pipe, Double
Fastener Strap Type
Page 18

Fig. 2WON
Fig. 2FWON
Adjustable Band Hanger
Adjustable Band
w/o Swivel Nut
Hanger
MSS-SP-69, Type 7
w/o Swivel Nut
WW-H-171E, Type 7
with Felt Lining
Page 10
MSS-SP-69, Type 10
WW-H-171E, Type 10
Fig. 200WON
Page 10
Trimline Band Hanger
w/o Swivel Nut
MSS-SP-69, Type 7
WW-H-171E, Type 7
Page 43

Fig. 3PVC
J-Hanger
with PVC Coating
MSS-SP-69, Type 5
Page 11

Fig. 120
U-Hanger
Page 37

Fig. 28
Standoff Hanger and
Restrainer for CPVC
Plastic Pipe
Page 22

Fig. 200
Trimline Band Hanger
MSS-SP-69, Type 10
WW-H-171E, Type 10
Page 41
Fig. 200F
Heavy Duty Band
Hanger (for Trapeze)
MSS-SP-69, Type 10
WW-H-171E, Type 10
Page 42

Fig. 120RWA (B)


Retrofit Wrap Around
U-Hanger Clamp
MSS-SP-69, Type 4
WW-H-171E, Type 4
Page 38

Fig. 29
CPVC Double Offset
Page 23

NOTE: For more information on TOLCO products, please see TOLCO Pipe Hangers and Support Systems Catalog.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 3/1/2008

Index

Pipe Clamps

Fig. 4B
Seismic
Pipe Clamp
Page 14

Fig. 4
Standard Pipe Clamp
MSS-SP-69, Type 4
WW-H-171E, Type 4
Page 12

Fig. 4F
Standard Pipe Clamp
with Felt Lining
MSS-SP-69, Type 4
WW-H-171E, Type 4
Page 12

Fig. 4A
Pipe Clamp for
Sway Bracing
Page 13

Fig. 4PVC
PVC Coated
Pipe Clamp
Page 12

Fig. 6
Riser Clamp
MSS-SP-69, Type 8
WW-H-171E, Type 8
Page 16

Fig. 6F
Riser Clamp
with Felt Lining
MSS-SP-69, Type 8
Ww-H-171E, Type 8
Page 16

Fig. 6PVC
PVC Coated
Riser Clamp
MSS-SP-69, Type 8
WW-H-171E, Type 8
Page 16

Beam Clamps and Accessories

Fig. 61T
Threaded Top Hook
Page 27

Fig. 65
Steel Reversible
"C" Type Beam Clamp
with Lock Nut
3/4" Opening
MSS-SP-69,
Type 19 & 23
WW-H-171E, Type 23
Page 28

Fig. 66
Steel Reversible
"C" Type Beam Clamp
with Lock Nut
11/4" Opening
MSS-SP-69,
Type 19 & 23
WW-H-171E, Type 23
Page 28

Fig. 69
Beam Clamp
Retaining Strap
Page 31

Fig. 69R
Retrofit Capable
Beam Clamp
Retaining Strap
Page 31

Fig. 130
Beam Clamp with
Bolt and Nut
Page 39

Upper Attachments

Fig. 42
Angle Bracket
Page 24

Fig. 50
Side Beam Bracket
Page 24
Fig. 51
Side Beam Bracket
for NFPA Pipe Sizing
Page 25

Fig. 58
Threaded Side
Beam Bracket
Page 26

Fig. 75
Swivel
Page 32

Fig. 78
All Steel
Ceiling Plate
Page 33

NOTE: For more information on TOLCO products, please see TOLCO Pipe Hangers and Support Systems Catalog.
OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 6/9/2008

Index

Concrete Inserts

Fig. 109A
Concrete Deck Insert
Page 35

Fig. 109AF
Concrete Insert
Page 36

Fig. 150
"Wing-It" Concrete Deck Insert
Page 41

Threaded Products & Accessories

Fig. 98
Rod Stiffener
Page 34

Seismic Brace Attachments

Fig. 4L
Longitudinal In-Line
Sway Brace Attachment
Page 15

Fig. 907
4-Way Longitudinal
Sway Brace Attachment
Page 48

Fig. 981
Retrofit Universal Sway
Brace Attachment
Page 53

Fig. 25
Surge Restrainer
Page 20

Fig. 800
Adjustable Sway Brace
Attachment to Steel
Page 44

Fig. 909
No-Thread Swivel
Sway Brace Attachment
Page 49

Fig. 990
Cable Sway Brace
Attachment
Page 54

Fig. 910
Swivel
Sway Brace Fitting
Page 50

Fig. 991
Cable Sway Brace
Attachment
Page 55

Fig. 825
Bar Joist Sway
Brace Attachment
Page 45

Fig. 825A
Bar Joist Sway
Brace Attachment
Page 46

Fig. 975
Straight
Sway Brace Fitting
Page 51

Fig. 906
Sway Brace
Multi-Fastener Adapter
Page 47

Fig. 980
Universal Swivel
Sway Brace Attachment
Page 52

Fig. 1000
Fig. 1001
"Fast Clamp"
Sway Brace Attachment
Sway Brace Attachment
Page 57
Page 56

Fig. 2002
Sway Brace Attachment
Page 58

NOTE: For more information on TOLCO products, please see TOLCO Pipe Hangers and Support Systems Catalog.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007
Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 1 - Standard Clevis Hanger


Size Range Size 1/2" thru 36" pipe.
Material Carbon Steel
Function Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield.
Note When an oversized clevis is used, a pipe spacer should
be placed over the cross bolt to assure that the lower U-strap
will not move in on the bolt. When attaching seismic bracing
to clevis hangers, a Fig. 1 CBS (cross bolt spacer) must be
installed. See TOLCO Seismic Restraint Approval Guidelines.
Approvals Underwriters Laboratories Listed in the USA (UL),
Canada (cUL) 3/4" thru 8". Conforms to Federal Specification
WW-H-171E, Type 1, and Manufacturers Standardization
Society SP-69, Type 1. Also available to accommodate rod
schedule per National Fire Protection Association (NFPA)
Pamphlet 13. Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide Health
Planning and Development (OSHPD). For additonal load,
spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems
Guidelines.
Maximum Temperature 650F
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless Steel.

Dimensions Weights
Pipe
Size

Rod Size A
STD
NFPA

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1

3/8
3/8
3/8

3/8
3/8
3/8

2116
278
314

1316
178
2116

1
1
1

610
610
610

36
38
42

114
112
2

3/8
3/8
3/8

3/8
3/8
3/8

3916
378
4716

214
238
234

1
1
1

610
610
610

46
49
55

212
3
312

1/2
1/2
1/2

3/8
3/8
3/8

5516
51516
6716

314
312
334

1
114
114

1130
1130
1130

124
140
152

4
5
6

5/8
5/8
3/4

3/8
1/2
1/2

738
81516
91316

414
514
512

112
112
112

1430
1430
1940

190
235
317

8
10
12

3/4
7/8
7/8

1/2
5/8
5/8

12916
1614
18916

718
958
101316

2
314
318

2000
3600
3800

428
918
1086

14
16
18

1
1
1

2034
2278
2534

1238
13316
15932

4
334
4716

4200
4600
4800

1267
1930
2264

20
*24
*30
*36

114
114
114
112

281316
3218
3878
48

17116
1814
2178
2734

5316
4716
5
534

4800
4800
6000
9500

3531
4431
6940
18103

*Furnished with pipe spacer to support maximum load rating

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Fig. 1CBS - Clevis Bolt Spacer

Component of State of
California OSHPD Approved
Seismic Restraints System

Size Range Size 1" thru 20" clevis hanger


Material Carbon Steel
Function Used as a spacer at a seismic brace location to
keep clevis hanger from collapsing during seismic event.
Approvals Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide Health
Planning and Development (OSHPD). For additional load,
spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems
Guidelines.
Installation Note Fig. 1CBS fits easily over the cross bolt
and attaches by pinching tabs down.
Finish Mil Galvanized
Note Available in HDG finish or Stainless Steel materials.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Fig. 1F Felt Lined Standard Clevis Hanger


Fig. 1PVC PVC Coated Standard Clevis Hanger
Size Range Size 1/2" thru 8" pipe.
Material Carbon Steel
Insulation Material 3/16" felt
Function The Fig. 1F is designed for the suspension of copper
tube so as to prevent electrolysis between tube and hanger. The
Fig. 1PVC is designed for steel or other pipe types of same O.D.
Both Fig. 1F and Fig. 1PVC act to reduce noise and vibration in
pipe or tube system.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL).
Maximum Temperature 650F
Finish Plain
Note When Fig. 1F is used for steel or other pipe types, consult
factory for proper size hanger. Available in Electro-Galvanized and
HDG finish or Stainless Steel.
Order By Figure number, nominal tube size and finish

Fig. 1F

Fig. 1PVC
Dimensions Weights
Pipe
Size

Rod Size A
STD
NFPA

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1

3/8
3/8
3/8

3/8
3/8
3/8

27/8
31/16
33/8

1
111/16
17/8

1
1
1

610
610
610

36
38
43

114
112
2

3/8
3/8
3/8

3/8
3/8
3/8

33/4
41/16
412

21/16
23/16
29/16

1
1
1

610
610
610

47
50
56

212
3
312

1/2
1/2
1/2

3/8
3/8
3/8

512
61/8
63/4

31/16
35/16
39/16

1
114
114

1130
1130
1130

125
141
153

4
5
6
8

5/8
5/8
3/4
3/4

3/8
1/2
1/2
1/2

75/8
87/8
10
123/4

41/16
51/16
55/16
615/16

112
112
112
2

1430
1430
1940
2000

191
236
318
429

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 2 Adjustable Band Hanger


Fig. 2NFPA Adjustable Band Hanger with Reduced Rod
Size Range Size 21/2" thru 6" pipe.
Material Carbon Steel, Pre-Galvanized
Function Recommended for the suspension of non-insulated pipe or
insulated pipe with Fig. 220 shield.
Fig. 2NFPA accommodates the reduced rod schedule of the National Fire
Protection Association Pamphlet 13.
Approvals Factory Mutual Engineering approved. Underwriters
Laboratories Listed. Conforms to Federal Specification WW-H-171E,
Type 10 and Manufacturers Standardization Society SP-69, Type 10.
Finish Pre-Galvanized
Note Available in Stainless Steel materials.
Order By Figure number, pipe size and material

Dimensions Weights

*
**

Pipe
Size

Rod Size

Max. Rec.
Load Lbs.

212
3
312
4
5
6

1/2*
1/2*
1/2*
5/8*
5/8**
3/4**

53/4
6
73/8
73/8
9
93/8

414
41/8
514
5
61/8
612

15/8
114
21/8
15/8
214
17/8

600
600
600
1000
1250
1250

Approx Wt./100
Fig. 2
Fig. 2NFPA
41
45
52
59
97
139

3/8" nut is used when NFPA rod sizing is requested.


1/2" nut is used when NFPA rod sizing is requested.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

40
43
50
56
95
105

www.tolco.com
Revision 9/1/2006

Fig. 2F - Adjustable Band Hanger with Felt Lining


Size Range 1/2" thru 6" copper tubing
Material Carbon Steel, Pre-Galvanized
Function Recommended for the suspension of copper tube so
as to prevent electrolysis. The felt lining also acts to reduce noise in
copper or other pipe types.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL). Conforms to Federal
Specification WW-H-171E, Type 10 and Manufacturers
Standardization Society SP-69, Type 10.
Finish Pre-Galvanized
Note When used for steel or other pipe types, consult factory
for proper size. Available in Stainless Steel materials.
Order By Figure number and copper tube size

Dimensions Weights
Copper Tube
Size

Rod Size

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1

3/8
3/8
3/8

31/8
31/8
33/8

25/8
212
25/8

13/8
11/8
11/8

400
400
400

12
12
13

114
112
2

3/8
3/8
3/8

33/4
37/8
414

27/8
27/8
3

114
11/8
1

400
400
400

14
15
16

212*
3*
312*

1/2
1/2
1/2

53/4
6
73/8

41/8
4
514

13/4
112
13/8

600
600
600

41
46
53

4*
5**
6**

5/8
5/8
3/4

73/8
9
93/8

5
61/8
612

17/8
212
214

1000
1250
1250

60
98
140

* 3/8" nut is used when requested.


** 1/2" nut is used when requested.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 3/1/2007
Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 2WON - Adjustable Band Hanger w/o Swivel Nut


Fig. 2FWON - Felt Lined Band Hanger w/o Swivel Nut
Size Range (Fig. 2WON) Size 2" thru 8" pipe.
(Fig. 2F WON) 1/2" thru 8" copper tube
Material Pre-Galvanized Steel
Function Recommended for the suspension of non-insulated
pipe or insulated pipe with Fig. 220 shield.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Conforms to Federal Specification WW-H-171E,
Type 7, and Manufacturers Standardization Society SP-69, Type
7, 3/4" thru 6". Figure 2WON is included in our Seismic Restraints
catalog approved by the state of California.
Finish Pre-Galvanized
Note Available in Stainless Steel materials.
Order By Figure number and pipe size

Fig. 2WON

Fig. 2F WON
Dimensions Weights
Pipe
Size

Rod Size
A

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1

3/8
3/8
3/8

25/8
25/8
27/8

21/8
2
21/8

114
1
1

400
400
400

14
14
16

114
112
2

3/8
3/8
3/8

33/8
312
33/4

212
212
212

114
1
7/8

400
400
400

17
18
20

212
3
312

1/2*
1/2*
1/2*

5
512
63/4

312
35/8
45/8

112
114
2

600
600
600

27
40
48

4
5
6
8

5/8*
5/8**
3/4**
3/4**

63/4
812
914
1214

43/8
55/8
57/8
77/8

112
21/8
15/8
25/8

1000
1250
1250
1250

53
91
99
120

* 3/8" nut is used when NFPA rod sizing is requested.


** 1/2" nut is used when NFPA rod sizing is requested.

10

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Component of State of

Fig. 3 - J-Hanger for Pipe or Conduit


California OSHPD Approved
Seismic Restraints System
Fig. 3F - Felt Lined J-Hanger for Copper Tubing
Fig. 3PVC - PVC Coated J-Hanger for Pipe or Conduit
Size Range 1/2" thru 12" pipe size
Material Carbon Steel
Function Recommended for the suspension of non-insulated pipe, or
insulated pipe with Fig. 220 shield. Side hole allows for wall mounting.
Fig. 3F and Fig. 3PVC are designed to reduce noise and vibration and/or
prevent electrolysis between pipe and hanger.
Approvals Conforms to Manufacturers Standardization Society SP69, Type 5. Included in our Seismic Restraints Catalog approved by the
State of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating
to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems
Guidelines.
Finish Electro-Galvanized
Note Available in HDG finish or Stainless Steel materials.
Order By Figure number, pipe size and finish

Fig. 3

Fig. 3PVC

Fig. 3F

Dimensions Weights
Copper Tube
Size

Rod Size
A

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1

3/8
3/8
3/8

258
278
21516

134
178
11516

7/16
7/16
7/16

112
11116
11316

11516
218
2516

400
400
400

18
21
22

114
112
2

3/8
3/8
3/8

314
3916
31116

2
2316
218

7/16
7/16
7/16

2116
2716
2916

258
278
3116

400
400
400

25
27
29

212
3
312

1/2
1/2
1/2

4716
41316
518

2716
2916
258

9/16
9/16
9/16

3316
312
334

358
4116
438

500
500
500

64
72
84

4
5
6

5/8
5/8
3/4

618
634
734

3316
314
3916

9/16
9/16
9/16

458
5116
51316

5316
534
658

550
550
600

138
162
249

8
10

7/8
7/8

9316
1034

31516
378

9/16
9/16

61516
758

8
918

760
760

291
315

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

11

www.tolco.com
Revision 3/7/2007

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 4 - Standard Pipe Clamp


Fig. 4F - Standard Pipe Clamp Felt Lined
Fig. 4PVC - Standard Pipe Clamp PVC Coated

Size Range (Fig. 4) Size 1/2" thru 30" pipe.


Size Range (Fig. 4F) Size 1/2" thru 212" copper tubing
Material Carbon Steel
Function Recommended for the suspension of non-insulated pipe or insulated pipe with
Fig. 220 shields. (Use Fig. 330 Weldless Eye Nut, Fig. 102 Eye Rod or Fig. 101 Welded Eye
Rod.) Also recommended for attachment of sway bracing up to 31/2" pipe size, for larger
pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce noise and vibration
and/or prevent electrolysis.
Approvals Underwriters Laboratories Listed in the USA (UL), Canada (cUL) 1/2" - 8",
and approved by Factory Mutual Engineering, 3/4" - 8". Federal Specification WW-H-171E,
Type 4, 112" thru 24" and Manufacturers Standardization Society SP-69, Type 4. Included
in our Seismic Restraints Catalog approved by the State of California Office of Statewide
Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer
to the TOLCO Seismic Restraint Systems Guidelines.
Note When the Fig. 4 is used as a sway brace, to ensure performance, the UL Listing requires that it must be used with other
TOLCO brace products.
Maximum Temperature 750F
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless
Steel materials.
Order By Figure number, pipe size and finish.
Fig. 4F
Order Note When ordering Fig. 4F allow for 3/16" felt on each half of clamp.

Fig. 4

Fig. 4PVC

Dimensions Weights
Max. Design Load Lbs.
For Service Temp.
650
750F

Pipe
Size

Bolt Size

1/2
3/4
1

3716
3916
3916

1/4
1/4
1/4

118
114
114

118
114
1516

5/16
5/16
5/16

500
500
500

445
445
445

29
31
35

114
112
2*

4316
4916
5916

3/8
3/8
3/8

138
158
2

11116
178
214

5/16
5/16
3/8

500
800
1040

445
715
930

40
42
93

212*
3*
312*

6716
7
71116

3/8
3/8
3/8

212
234
318

234
3116
338

1/2
1/2
1/2

1040
1040
1040

930
930
930

126
141
154

4
5
6

812
934
1158

5/8
3/4
3/4

3516
378
478

31116
438
518

1/2
5/8
3/4

1040
1040
1615

930
930
1440

229
261
537

8
10
12

13516
1612
1812

1
1
1

558
714
814

6
714
814

3/4
7/8
7/8

1615
2490
2490

1440
2220
2220

625
1378
1574

14
16
18

20
23
2578

118
118
114

9
1014
1112

9
1014
1112

7/8
7/8
1

2490
2490
3060

2220
2220
2730

2103
2314
3276

20
24
30

28
3312
4178

138
158
2

1212
1514
19

1212
1514
19

118
114
134

3060
3060
3500

2730
2730
3360

3863
5222
10511

*Meets UL 203A requirements for attachment of sway bracing. Horizontal design load for 1/2"-2" - 380#, 212" - 395#, 3" - 435#, 312" - 540#

12

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

Approx.
Wt./100

www.tolco.com
Revision 3/1/2008

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 4A - Pipe Clamp for Sway Bracing


Size Range 4" thru 8" pipe. For sizes smaller than 4" use TOLCO Fig. 4.
Material Carbon Steel
Function For bracing pipe against sway and seismic disturbance.
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada
(cUL) 4" thru 8". Included in our Seismic Restraints Catalog approved by
the State of California Office of Statewide Health Planning and Development
(OSHPD).
Installation Instructions The Fig. 4A is the "braced pipe" attachment
component of a longitudinal, lateral or riser brace assembly. It is intended to
be combined with the "bracing pipe" and TOLCO transitional and structural
attachment component(s) to form a complete bracing assembly. NFPA 13
and/or OSHPD guidelines should be followed.
To Install Place the Fig. 4A over the pipe to be braced. Attach TOLCO
transitional fitting, either Fig. 980, 910 or 909, to the clamp ears. Tighten bolts
and nuts; torque requirement is a minimum of 50 ft. lbs. Transitional fitting
attachment can pivot for adjustment to proper brace angle.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless Steel
materials.
Order By Figure number, pipe size and finish

Fig. 4A - Longitudinal Brace


TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind,
including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

Dimensions Weights
Pipe
Sizes

Bolt Size

Max. Horizontal
Design Load

Approx.
Wt./100

4
5
6
8

812
934
1112
1314

9/16
9/16
5/8
3/4

338
378
5
61116

31116
438
518
618

1/2
1/2
1/2
1/2

2015
2015
2015
2015

221
253
513
601

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

13

www.tolco.com
Revision 9/1/2006

Fig. 4B - Pipe Clamp for Sway Bracing

Component of State of
California OSHPD Approved
Seismic Restraints System

Size Range 3/4" thru 8" pipe.


Material Carbon Steel
Function For bracing pipe against sway and seismic disturbance.
Features This product's design incorporates concentric loading of the "brace pipe",
connection components and fasteners which is critical to the performance of seismic
bracing assemblies.
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).
Included in our Seismic Restrains Catalog approved by the State of California Office of
Statewide Health Planning and Development (OSHPD).
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless Steel materials.
Order By Figure number, pipe size and finish.
Installation Instructions The Fig. 4B is the "braced
pipe" attachment component of a longitudinal or lateral
sway brace assembly. It is intended to be combined with
the "bracing pipe" and TOLCO transitional and structural
attachment component(s) to form a complete bracing
assembly. NFPA 13 and/or OSHPD guidelines should be
Shown with two TOLCO
followed.
Fig. 980s and Schedule 40
brace pipe.
To Install Place the Fig. 4B over the pipe to be braced.
Attach other TOLCO transitional fitting, Fig. 909, 910
or 980. Tighten bolts and nuts. Transitional fitting attachment can pivot for adjustment to proper brace angle.

Fig. 4B - Hanger/Longitudinal Brace

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind,
including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

Dimensions Weights

14

Pipe
Sizes

Rod Size
A

Bolt Size

Max. Design
Load Lbs.

Approx.
Wt./100

3/4
1
114

3/8
3/8
3/8

1
1
1

278
314
3916

258
21516
314

5/16
5/16
5/16

330
330
330

56
60
74

112
2
212

3/8
3/8
1/2

1
112
134

31316
518
558

3716
458
538

5/16
5/16
3/8

330
440
440

79
156
176

3
312
4

1/2
1/2
5/8

178
2
2

634
714
858

618
634
714

3/8
3/8
1/2

660
660
800

198
219
288

5
6
8

5/8
3/4
7/8

2
218
218

978
101516
13716

8516
912
1112

5/8
5/8
3/4

980
980
1200

390
448
691

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/27/2008

Fig. 4L
Longitudinal In-Line Sway Brace Attachment
Size Range 2" through 8" IPS.
Material Carbon Steel
Function For bracing pipe against sway and seismic disturbance.
Approvals Underwriter's Laboratories Listed in the USA (UL) and
Canada (cUL) 2" - 8". Approved by Factory Mutual Engineering (FM),
2" - 8" pipe.
Installation Instructions The Fig. 4L is the "braced pipe" attachment
component of a longitudinal sway brace assembly. It is intended to be
combined with the "bracing pipe" and TOLCO structural attachment
component to form a complete bracing assembly. NFPA 13 and/or
OSHPD guidelines should be followed.
To Install Place the Fig. 4L over the pipe to be braced and tighten
bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt
until hex head snaps off. Jaw attachment can pivot for adjustment to
proper brace angle.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, pipe size and finish.

4-Way Riser Brace


(Plan view)

Dimensions Weights
Sizes
Longitudinal Brace

212
3
4
5
6
8

6716
7
812
934
1112
1314

212
234
338
378
5
61116

234
3116
31116
438
518
618

Bolt
Size
1/2
1/2
1/2
1/2
1/2
1/2

Max. Rec.
Load Lbs.

*Max Rec.

(cULus)

(FM)

Approx.
Wt./100

2015
2015
2015
2015
2015
2015

3000
1550
1550
1450
1450
1450

253
268
348
380
640
728

Load Lbs.

Load shown is allowable with brace installed, between 30 - 90. No reduction of load
*based
on brace angle is required.
FM approved when used with 1", 114", 112" or 2" Sch. 40 brace pipe.
TOLCO brand bracing components are designed to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed seismic
bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance that such
TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind,
including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

15

www.tolco.com
Revision 9/1/2006

Fig. 6 - Riser Clamp


Fig. 6F - Felt Lined Riser Clamp
Fig. 6PVC - PVC Coated Riser Clamp
Size Range (Fig. 6) 1/2" thru 20" pipe
(Fig. 6F) 1/2" thru 212" copper tubing
(Fig. 6PVC) 1/2" thru 6" pipe
Material Carbon Steel
Insulation Material (Fig. 6F) 3/16" felt.
Function Used for supporting vertical piping.
Approvals Underwriters Laboratories Listed in the USA (UL), Canada
(cUL) 1/2" - 8". Factory Mutual Engineering Approved, 3/4" thru 8".
Conforms to Federal Specification WW-H-171E, Type 8, 3/4" thru 20" and
Manufacturers Standardization Society SP-69, Type 8.
Maximum Temperature 650F
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless Steel
materials.
Order By (Fig. 6 and Fig. 6PVC) pipe size and finish. (Fig. 6F) copper
tube size and finish. (Fig. 6F is available for Iron Pipe Size, consult factory.

Fig. 6

Fig. 6PVC

Fig. 6F

Dimensions Weights

16

Pipe
Size

Bolt Size

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1

914
914
9916

1/2
1/2
1/2

118
118
114

3/8
3/8
3/8

255
255
255

144
144
147

114
112
2

91116
1038
1034

1/2
1/2
1/2

138
112
2

3/8
3/8
3/8

255
255
255

150
153
165

212
3
312

11
12
13

5/8
5/8
5/8

214
3
314

3/8
3/8
1/2

390
530
670

228
246
264

4
5
6

1312
1412
1518

3/4
3/4
7/8

338
438
478

1/2
1/2
1/2

810
1160
1570

347
385
564

8
10

1812
2014

1
1

534
714

5/8
5/8

2500
2500

1017
1138

12
14
16
18
20

2234
24
26
28
30

1
118
118
114
138

814
9
1014
1112
1212

5/8
5/8
3/4
3/4
3/4

2700
2700
2900
2900
2900

1759
1922
3245
3372
3499

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 10/24/2007

Fig. 22 - Hanger for CPVC Plastic Pipe


Single Fastener Strap Type
Size Range 3/4" thru 2" CPVC pipe
Material Pre-Galvanized Steel
Function Intended to perform as a hanger to support CPVC piping used
in automatic fire sprinkler systems. The product acts as a hanger when tab
is upward and the fastener screw is in the horizontal position. Figure 22 can
be installed on the top of a beam, but in this situation acts as a guide to
the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. For
this type of installation, use the TOLCO Fig. 23, Double Fastener Strap for
CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can
function as a restrainer to prevent the upward movement of the sprinkler
head during activation.
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada
(cUL) to support fire sprinkler piping. May be installed in wood using
fasteners supplied with product, or into minimum 20 gauge steel using (1)
1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13,
13R and 13D.
Features Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed
hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No
impact tools (such as a hammer) are allowed. Damage has been know to result from installations using impact type
tools. No pre-drilling of a pilot hole in wood is required.
Finish Pre-Galvanized
Order By Figure number and CPVC pipe size.

Dimensions Weights
CPVC
Pipe Size

Max. Hanger
Spacing (Ft.)

Fastener Hex
Head Size

Approx.
Wt./100

3/4
1
114
112
2

2716
21116
3116
3516
334

1516
1716
158
134
218

1316
1316
1316
1316
1316

512
6
612
7
8

5/16
5/16
5/16
5/16
5/16

9
9
11
12
15

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

17

www.tolco.com
Revision 12/10/2007

Fig. 23 - Hanger for CPVC Plastic Pipe


Double Fastener Strap Type
Size Range 3/4" thru 3" CPVC pipe
Material Pre-Galvanized Steel
Function Intended to perform as a hanger/restrainer to support
CPVC piping used in automatic fire sprinkler systems. Fig. 23 can
be installed on the top, bottom or side of a beam. The Fig. 23 also
functions as a restrainer to prevent the upward movement of the
sprinkler head during activation.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL) to support fire sprinkler piping. May be installed
in wood using fasteners supplied with product, or into minimum 20
gauge steel using (2) 1/4" x 1" tek type screw. Meets and exceeds
the requirements of NFPA 13, 13R and 13D.
Features Fig. 23 incorporates features which protect the pipe
and ease installation. The flared edge design protects the CPVC
pipe from any rough surface. It also incorporates snap restrainers
allowing easier and faster installation. Easily attaches to the building
structure using the two UL Listed hex head self threading screws*
furnished with the product. It is recommended that rechargeable
electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed.
Damage has been known
to result from installations using impact type tools.
No pre-drilling of a pilot hole in wood is required.
Finish Pre-Galvanized
Order By Figure number and pipe size
* Hardened hex head self threading screw is furnished with the
product and is the minimum fastener size acceptable.

Dimensions Weights

18

CPVC
Pipe Size

Max. Hanger
Spacing (Ft.)

Fastener Hex
Head Size

Approx.
Wt./100

3/4
1
114
112
2
21/2
3

318
338
4316
4716
478
109/32
117/8

1916
11116
2332
2732
2716
211/16
3

1316
1316
1316
1316
1316
13/16
13/16

512
6
612
7
8
9
10

5/16
5/16
5/16
5/16
5/16
5/16
5/16

9
9
11
12
15
22
25

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 24 - Hanger for CPVC Plastic Pipe


Double Fastener Strap Type - Side Mount
Size Range 3/4" thru 2" CPVC pipe
Material Pre-Galvanized Steel
Function Intended to perform as a hanger/restrainer to support
CPVC piping used in automatic fire sprinkler systems. Can be installed
on the top or on the bottom of a beam. The Fig. 24 can also function
as a restrainer to prevent the upward movement of the sprinkler head
during activation.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL) to support fire sprinkler piping. May be installed in wood using
fasteners supplied with product, or into minimum 20 gauge steel using (2)
1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13,
13R and 13D.
Features Fig. 24 incorporates features which protect the pipe and
ease installation. The flared edge design protects the CPVC pipe from
any rough surface. Easily attaches to the building structure using the two
UL Listed hex head self threading screws* furnished with the product. It
is recommended that rechargeable electric drills fitted with a hex socket
attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using
impact type tools. No pre-drilling of a pilot hole in wood is required.
Finish Pre-Galvanized
Order By Figure number and pipe size
* Hardened hex head self threading screw is furnished with the
product and is the minimum fastener size acceptable.

Dimensions Weights
CPVC
Pipe Size

Max. Hanger
Spacing (Ft.)

Fastener Hex
Head Size

Approx.
Wt./100

3/4
1
114
112
2

2516
258
3
314
31116

1532
1516
112
158
12732

1316
1316
1316
1316
1316

512
6
612
7
8

5/16
5/16
5/16
5/16
5/16

9
9
11
12
15

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

19

www.tolco.com
Revision 3/1/2008

Fig. 25 - Surge Restrainer


Size Range One size fits 3/4" thru 2" pipe.
Material Pre-Galvanized Steel
Function Designed to be used in conjunction with TOLCO Band Hangers to
restrict the upward movement of piping as it occurs during sprinkler head
activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product
is intended to satisfy the requirements as indicated in the National Fire Protection
Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to
restrain either steel pipe or CPVC plastic Pipe.
Approvals Underwriters Laboratories Listed only when used with TOLCO
band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and
Canada (cUL).
Finish Pre-Galvanized
Order By Figure number and TOLCO band hanger, size from 3/4"
thru 2".
Patent #5,344,108

20

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Fig. 28
"Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe
Size Range " through 2"
Material Carbon Steel, Pre-Galvanized
Function Designed to be used as a hanger and restrainer for CPVC piping where
the "stand-off" design will ease installation by eliminating the need for wood blocking.
Features:
Flared edge design protects CPVC pipe from any rough or abrasive surfaces.
Unique twist and lock design holds pipe firmly in place and allows retrofit type
of installation.
The "Stand-Off" design eliminates the need for wood block extension.
Can be installed on horizontal or vertical piping regardless of mounting
surface orientation.
Attaches easily to wood structure with two hex head self-threading screws
furnished with product.
Installs easily using rechargeable electrical driver with 5/16" extension socket
eliminating impact tool damage to pipe.
Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling
tapping screws.
U.L. Listed as a hanger and a restrainer for fire sprinkler piping.
Approvals Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to
support automatic fire sprinkler systems. May be installed into wood using fasteners
supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws.
Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL
vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint
when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when
used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed
screw when used as a hanger only.
Order by Figure number and pipe size.
PATENT # 10446292

Dimensions Weights
Pipe
Size

3/4
1
114
112
2

3132
3516
358
4
412

Approx.
Wt.

2
2316
238
212
21116

312
312
312
312
358

.180
.210
.225
.310
.340

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

21

www.tolco.com
Revision 6/9/2008

Fig. 29 - Double Offset Hanger & Restrainer for CPVC


Plastic Pipe
Size Range Available in 3/4" and 1" pipe sizes
Material Pre-Galvanized Steel
Function Intended to perform as a hanger and restrainer for
CPVC, plastic fire sprinkler pipe. Provides double offset 1 x
1 from mounting surface. This design will ease installation by
eliminating the need for wood block extension and allow retro-fit
attachment of hanger to sprinkler pipe.
Features
Thumb tab provides protection to restrain pipe in rough job site
conditions. Tab is not required to be bent for listed installation.
Offset edge eliminates abrasion.
Attaches easily to wood structure with two special #10 x 1 hex
head self-threading screws furnished with product.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL) as a hanger and restrainer to support fire
sprinkler systems. Meets and exceeds requirements of NFPA 13,
13R and 13D.
Finish Pre-Galvanized
Order By Figure number and pipe size.

1.500

1.500

PATENT PENDING

Double Offset

Single Offset

Install using a rechargeable electric drill fitted with a 5/16 socket attachment with the special hex head self-tapping
screws provided. Install screws until they bottom out. Pipe can be snapped into hanger before or after installation of
the screws to the mounting surface. Thumb tab may be bent up to provide additional protection to the pipe, but is not
required for performance of the hanger / restrainer function.

22

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Fig. 42 - Angle Bracket


Material Carbon Steel
Function Recommended for supporting pipe at various
distances from wall or column.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or
Stainless Steel materials.
Order By Figure number, size and finish

Dimensions Weights
Size

Hole
Size

Max. Rec.
Load Lbs.

1
2
3
4

3
4
3
4

2
3
2
3

7/16
7/16
9/16
9/16

180
180
390
390

Approx.
Wt./100
46
65
85
115

Fig. 50 - Side Beam Bracket


Size Range 3/8" thru 7/8" rod
Material Carbon Steel
Function Recommended for attaching hanger rod to side
of beams or walls.
Approvals 3/8", Underwriters Laboratories Listed in
the USA (UL) and Canada (cUL), and Factory Mutual
Engineering approved.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or
Stainless Steel materials.
Order By Figure number, rod size and finish

Dimensions Weights
Rod
Size

Hole
Size

Max. Rec.
Load Lbs.

3/8
1/2
5/8
3/4
7/8

2
2
2
212
212

3/4
3/4
3/4
3/4
3/4

2
2
2
212
212

7/16
9/16
11/16
13/16
15/16

700
700
700
1250
1250

Approx.
Wt./100
35
35
32
110
100

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

23

www.tolco.com
Revision 9/1/2006

Fig. 51 - Side Beam Bracket for


NFPA Rod and Fastener Sizing
Size Range 3/8" and 1/2" rod, 1/2" thru 8" pipe
Material Carbon Steel
Function Recommended for attaching hanger rod to side of
beams or walls. Designed to accommodate current rod schedule and fastener requirements per National Fire Protection
Association (NFPA) Pamphlet 13.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL), and Factory Mutual Engineering approved.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or
Stainless Steel materials.
Order By Figure number, rod size and finish

Dimensions Weights
Pipe

Rod

Size

Size

1/2 - 2
212 - 4
5-6
8

24

3/8
3/8
1/2
1/2

Hole Size
A

H-1

H-2

Max. Rec.
Load Lbs.

2
2
212
212

3/4
3/4
3/4
3/4

2
2
212
212

7/16
9/16
9/16
11/16

7/16
7/16
9/16
9/16

700
700
1250
1250

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

Approx.
Wt./100
35
34
71
70

www.tolco.com
Revision 12/10/2007

Fig. 58 - Threaded Side Beam Bracket


Size Range 3/8" rod, pipe sizes 1/2" thru 4"
Material Carbon Steel
Function Practical and economical bracket used to support
piping from wood, concrete or steel beams.
Features Unique design allows rod to be easily threaded into
bracket. Offset design permits unlimited rod adjustment. Center
mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA
13: 1/2" thru 2" pipe requires 3/8" fastener, 212" thru 4" pipe
requires 1/2" fastener.*
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL), and Factory Mutual Engineering approved thru
4" pipe.
*Note Additionally UL has listed the Fig. 58 with fasteners as
shown in table below.
Finish Plain
Note Available in Electro-Galvanized finish.
Order By Figure number and finish

UL Listed Fastener Table


Pipe Size

Qty.

2
2
212 - 4
312
4
4
4

2
1
1
2
2
2
2

Fastener Type

Material

#16 x 2 Drive Screws


Wood
3/8 Lag Bolt
Wood
1/2 Lag Bolt
Wood
1/4 x 112 Lag Bolt
Wood
1/4 x 2 Lag Bolts*
Wood
1/4 x 1 tek screws
14 gauge
1/4 x 1 tek screws
16 gauge

* No pre-drilling required

Dimensions Weights
Pipe
Size

Rod
Size

1/2 thru 4

3/8

234

112

118

Max. Rec. Approx.


Load Lbs.* Wt./100
300

14

* With safety factor of 5.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

25

www.tolco.com
Revision 9/1/2006

Fig. 61T - Bar Joist Hanger


Size Range 3/8" thru 1/2" rod sizes
Material Carbon Steel
Function Designed to hook on top chord of metal bar joist.
Hanger rod is threaded into product and secured with a washer
and nut.
Approvals Underwriters Laboratories Listed in the USA
(UL) and Canada (cUL) for up to 4" pipe with 3/8" rod, up to 6"
pipe with 1/2" rod.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or
Stainless Steel materials.
Order By Figure number, rod size, width and thickness of
bar joist. Threaded hole will be center of that width.

Dimensions
Pipe

26

Size

Rod
Size

Max. Rec.
Load Lbs.

Up to 4
6

3/8
1/2

300
600

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Fig. 65 and Fig. 66


Reversible C-Type Beam Clamps 3/4" and 114" Throat Openings
Size Range (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod
Material Carbon Steel with hardened cup point set screw and
jam nut
Function Recommended for hanging from steel beam where flange
thickness does not exceed 3/4" (Fig. 65) or 114" (Fig. 66).
Features All steel construction eliminates structural deficiencies
associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange
where clearance is limited.) May be installed with set screw in up
or down position. Offset design permits unlimited rod adjustment by
allowing the rod to be threaded completely through the clamp. Open
design permits inspection of thread engagement.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL). Exceeds requirements of the National Fire Protection
Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4"
pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic
Restraints Catalog approved by the State of California Office of
Statewide Health Planning and Development (OSHPD). For additional
load, spacing and placement relating to OSHPD projects, please refer
to the TOLCO Seismic Restraint Systems Guidelines.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, rod size and finish

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 65 Patent #4,570,885

Fig. 65

Dimensions Weights
Rod Size
A

3/8
1/2
5/8

1316
112
112

3/4
3/4
3/4

1
1
1

7/16
9/16
9/16

1
114
114

Max. Rec. Approx.


Load Lbs.* Wt./100
610
1130
1130

28
55
55

* Max. loads for clamp with set screw in up or down position.

Fig. 66

Dimensions Weights
Rod Size
A

3/8
1/2
5/8

1316
112
112

114
114
114

1
1
1

7/16
9/16
9/16

1
114
114

Max. Rec. Approx.


Load Lbs.* Wt./100
610
1130
1130

28
55
55

* Max. loads for clamp with set screw in up or down position.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

27

www.tolco.com
Revision 12/10/2007

Fig. 67SS and Fig. 68SS Stainless Steel Reversible


C-Type Beam Clamps 3/4" Throat Opening/Wide Mouth
Stainless Steel
Size Range 3/8" and 1/2" rod sizes
Material All Stainless Steel (T-316 or T-304)
Function Recommended for hanging from steel beams where
flange thickness does not exceed 3/4" (Fig. 67SS) or 114" (Fig.
68SS).
Features All steel construction eliminates structural deficiencies
associated with casting type beam clamps. May be used on top
or bottom flange of the beam. May be installed with the set screw
in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the
clamp.
Approvals Underwriters Laboratories LIsted in the USA (UL)
and Canada (cUL). Conforms to Manufacturers Standardization
Society SP-69, Type 19. Meets or exceeds requirements of the
National Fire Protection Association (NFPA), pamphlet 13, 3/8"
rod will support 1/2" through 4" pipe, 1/2" rod will support 1/2"
through 8" pipe.
Order By Figure number and rod size

Fig. 67SS
Dimensions Weights
Pipe
Size

Stock
Size

Test
Load

Approx.
Wt./100

1/2 - 4
5, 6, 8

3/8
1/2

3
3

7/8
7/8

1
1

158
158

158
158

118
118

5/16 x 1
3/8 x 112

1500 lbs.
4050 lbs.

68
107

Fig. 67SS
Fig. 68SS
Dimensions Weights
Pipe
Size

Stock
Size

Test
Load

Approx.
Wt./100

1/2 - 4
5, 6, 8

3/8
1/2

2116
214

2
214

3/4
13/16

114
114

118
114

3/8 x 112
1/2 x 2

1500 lbs.
4050 lbs.

84
170

28

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 3/1/2008

Fig. 69 - Beam Clamp Retaining Strap


Size Range 3/8" thru 7/8" rod by 4" thru 16" length.*
Material Pre-Galvanized Steel
Function To offer more secure fastening of various types
of beam clamps to beam where danger of movement might
be expected. NFPA 13 requires the use of retaining straps
with all beam clamps installed in earthquake areas. Satisfies
requirements of NFPA 13 (1999) 6-4.7.1.
Important Note Good installation practice of a retaining
strap requires that the strap be held tightly and securely to all
component parts of the assembly. Therefore a locking mechanism of some kind such as a hex nut or the beveled locking
slot on the TOLCO Fig. 69R will provide a more secure
reliable installation.
Approvals Underwriters Laboratories listed in the
USA (UL) and Canada (cUL). Approved for use with any
listed beam clamp. Included in our Seismic Restraints
Catalog approved by the State of California Office of
Statewide Health Planning and Development (OSHPD). For
additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic
Restraint Systems Guidelines.
Finish Pre-Galvanized
Order By Figure number, type, length B and rod size
being used with beam clamp
Note Minimum return on Strap: 1".

Component of State of
California OSHPD Approved
Seismic Restraints System

Dimensions
Type

Rod Size A

Hole Size

3/8
1/2
5/8
3/4
3/8 - 7/8

7/16
9/16
11/16
13/16
Specify

Specify
Specify
Specify
Specify
Specify

2
3

* Longer lengths are available, consult factory.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

29

www.tolco.com
Revision 9/1/2006

Fig. 69R - Retrofit Capable Beam Clamp


Retaining Strap

Component of State of
California OSHPD Approved
Seismic Restraints System

Size Range 3/8" and 1/2" rod; 4" thru 16" length.**
Material Pre-Galvanized Steel
Function To offer more secure fastening of various types
of beam clamps to beam where danger of movement might
be expected. NFPA 13 requires the use of retaining straps
with all beam clamps installed in earthquake areas. Satisfies
requirements of NFPA 13 (1999) 6-4.7.1.
Features Beveled locking slot* is precisely formed to align
with the threaded section of a hanger rod or set screw and
engage the unit securely. May be used as shown in section
A-A or inverted. Allows easy installation for new construction
or retrofit applications.
Important Note Good installation practice of a retaining
strap requires that the strap be held tightly and securely to all
component parts of the assembly. Therefore a locking mechanism of some kind, such as the beveled locking slot of the Fig.
69R or a hex nut tightened against other types of retaining
straps will provide a more secure and reliable installation.
Approvals Underwriters Laboratories listed in the
USA (UL) and Canada (cUL). Approved for use with any
listed beam clamp. Included in our Seismic Restraints
Catalog approved by the State of California Office of
Statewide Health Planning and Development (OSHPD). For
additional load, spacing and placement information relating to
OSHPD projects, please refer to the TOLCO Seismic Restraint
Systems Guidelines.
Finish Pre-Galvanized
Order By Figure number, rod or set screw size and length
Note Minimum return on Strap: 1".
* Patent #5,947,424

Dimensions
Rod Size A
3/8"
1/2"

30

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

Length
Specify
Specify

www.tolco.com
Revision 3/1/2008

Fig. 75 - Swivel Attachment


Size Range 3/8" Rod Attachment
Material Carbon Steel
Function There are three recommended applications for
this product: May be used as a Branch Line Restraint for
structural attachment to anchor bolt, beam clamp, etc. May
be used in a pitched or sloped roof application, to meet
requirements of NFPA 13 (2002) Sec 9.1.2.5. May be used as
an upper attachment with short hanger rod to omit seismic
bracing (per UBC97).
Approvals Underwriters Laboratories Listed in the USA
(UL) and Canada (cUL) to support up to 4" pipe. Meets
requirements of Uniform Building Code (UBC) 1997 Table O,
Section 3.B.
Finish Electro-Galvanized
Order By Figure number

May be used as a structural attachment component of a


branch line restraint

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

31

www.tolco.com
Revision 1/24/2007

Fig. 78 - All Steel Ceiling Plate


Size Range 3/8" rod
Material Carbon Steel
Features Attachment to wood beams, ceilings, metal decks or
walls. Can also be welded to steel beams.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Additionally, (UL) has listed the Fig. 78 with
fasteners as shown in the table below.
Finish Plain and Electro-Galvanized
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, rod size and finish

C
B

Patent #5,702,077

D(2)

UL Listed Fastener Table


Pipe Size
1/2 - 2
212 - 4
1/2 - 2
1/2 - 2
1/2 - 2

Qty
2
2
2
2
2

Fastener Type

Material

A-point hex-washer-head sheet metal screw


1/4 x 112 wood screws*
1/4 x 1 tek screws
#14 x 114 A-point hex-washer-head sheet metal screw
#14 x 2 A-point-hex-washer-head sheet metal screw

Wood
Wood
Metal (18 gauge)
Wood
Wood thru 5/8" gyp board

#14 x

114

* No pre-drilling

Dimensions Weights
Pipe Size

1/2 - 2
5-6

218

118

5/16
3/8
Consult factory for data

Max. Rec.
Load Lbs.*

Approx.
Wt./100

150

15

* Minimum safety factor of 5

32

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 3/26/2008

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 98 - Rod Stiffener


Size Range Secures 3/8" thru 7/8" hanger rod
Material Carbon Steel
Function Secures channel to hanger rod for vertical seismic bracing.
Approvals Included in our Seismic Restraints Catalog approved
by the State of California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and placement
information relating to OSHPD projects, please refer to the TOLCO
Seismic Restraint Systems Guidelines
Finish Electro Galvanized
Note Available in HDG finish or Stainless Steel materials.
Order By Figure number

Fig. 99 - All Thread Rod Cut to Length


Size Range Secures 3/8" thru 7/8" rod in
1" increments
Material Carbon Steel
Maximum Temperature 750F
Finish Plain
Note Available in Electro-Galvanized and
HDG finish or Stainless Steel materials.
Order By Figure number, rod diameter, rod
length and finish

Dimensions
Rod
Size

Max. Rec. Load Lbs.


For Service Temp
650F

3/8
1/2
5/8
3/4
7/8

730
1350
2160
3230
4480

Fig. 100 - All Thread Rod Full Lengths


Size Range Secures 3/8" thru 112" rod in
10 lengths
Material Carbon Steel
Maximum Temperature 750F
Finish Plain
Note Available in Electro-Galvanized and
HDG finish or Stainless Steel materials.
Order By Figure number, rod diameter
and finish

Dimensions Weights
Rod
Size
1/4
3/8
1/2
5/8
3/4
7/8
1
114
112

Max Rec. Load Lbs.


For Service Temps
650F
240
730
1350
2160
3230
4480
5900
9500
13800

Approx.
Wt./100
12
29
53
84
123
169
222
360
510

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

33

www.tolco.com
Revision 6/11/2008

Fig. 109A - "NFPA" Concrete Deck Insert


Size Range 3/8" thru 7/8" rod
Material Carbon Steel
Function For use in metal deck formed concrete to attach hanger rods.
Allows for pre-positioning of hanger rods in poured concrete decks.
Approvals 3/8" - 5/8" rod size is Underwriters Laboratories listed in the
USA (UL) and Canada (cUL). Hangers certified by a registered professional
engineer to conform to Section 6-1.1 of NFPA #13 (1999) and Section
9.1.1.2 of NFPA 13 (2002).
Finish Plate: Plain Steel. Rod: Electro-Galvanized.
Note Available in HDG finish or Stainless Steel materials.
Order By Figure number, rod size and finish. Custom rod lengths are
available. Consult factory.

Spacing/Load Chart for 3000 PSI


Light Weight Concrete over 20 GA Steel Deck
Rod
Size

Max.
Pipe Size

Max. Hanger
Spacing

Max. Rec
Loads

3/8
1/2
5/8

4"
15'-0"
8"
15'-0"
Consult Factory Consult Factory

1144
1158
1430

3/4
7/8

Consult Factory Consult Factory


Consult Factory Consult Factory

2000
2000

NOTES:
1. Mounting holes are standard. If the plate is not
mechanically secured to the deck ribs, a jam nut is
required to prevent the anchor bolt from laying over
when concrete is poured.
2. Minimum spacing between inserts shall be not less
than 412" for 3/8" and 6" for 1/2"

Max. Rec. Loads shown include safety factory of 5.


3/8" - 4" Schedule 40 pipe incl. water wt. = 16.4 lb./ft. x 15 ft. - 246
x 5 (safety factor) + 250 = 1480 lbs.
1/2" - 8" Schedule 40 pipe incl. water wt. - 50.15 lb./ft. x 15 ft. 752.25 x 5 (safety factor) + 250 = 4011.25 lbs.

34

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 3/1/2008

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 109AF - Concrete Insert


Size Range 3/8" thru 7/8" rod
Material Carbon Steel
Function Designed to be embedded in concrete to provide a point of
attachment for hanger or seismic bracing.
Approvals Underwriters Laboratories listed in the USA (UL) and
Canada (cUL) for 3/8" and 1/2". Included in our Seismic Restraints
Catalog approved by the State of California Office of Statewide Health
Planning and Development (OSHPD). For additional load, spacing and
placement information relating to OSHPD projects, please refer to the
TOLCO Seismic Restraint Systems Guidelines.
Finish Plain anchor bolt with Electro-Galvanized hardware and plate.
Note For rod sizes 5/8" - 112" refer to Fig. 107F. Available in Stainless
Steel or HDG finish on request.
Order By Figure number, rod size and finish.
Note The Hex or Jam Nut has NO value in determining the loads. Their
function is to assist in locking the Coupling snug to the bottom of the deck
form preventing the concrete from leaking into the coupling threads. Any
other suitable locking device may be substituted if desired.

Dimensions
Rod
Size
3/8
1/2
5/8
3/4
7/8

Design Load Vertical

Design Load Shear

Hard Rock

Lt. Wt.

Hard Rock

Lt. Wt.

Hard Rock

Design Load 45
Lt. Wt.

E Embedment
Depth

De
min. (in.)

1255
2321
780
1346
2321

735
1392
468
806
1392

978
978
1278
1278
1278

733
733
958
958
958

777
980
688
927
1166

525
679
445
619
803

312
312
4
4
4

2
2
2
212
6

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

35

www.tolco.com
Revision 9/1/2006

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 120 - U Hanger


Size Range Size 3/4" thru 8" pipe
Material Carbon Steel
Function Used to support piping from wood beams where no
contraction is expected. Used extensively in automatic fire sprinkler systems.
Approvals Meets or exceeds the requirements of National
Fire Protection Association (NFPA), Pamphlet 13. Underwriters
Laboratories Listed in the USA (UL) and Canada (cUL). Included
in our Seismic Restraints Catalog approved by the State of
California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information
relating to OSHPD projects, please refer to the TOLCO Seismic
Restraint Systems Guidelines.
Maximum Temperature 750F
Finish Plain
Note Available in Electro-Galvanized and HDG finish or
Stainless Steel materials.
Order By Figure number, pipe size, length and finish

Dimensions
Pipe
Size

3/4
1
114
112
2
212
3
312
4
5
6
8

5/16
5/16
5/16
5/16
5/16
3/8
3/8
3/8
3/8
1/2
1/2
1/2

Fastener
Size
16 x 2*
16 x 2*
16 x 2*
16 x 2*
16 x 2*
3/8 x 212**
3/8 x 212**
3/8 x 212**
1/2 x 3**
1/2 x 3**
1/2 x 3**
5/8 X 3**

Max Rec.
Load Lbs.***
250
250
250
250
250
320
320
560
560
560
760

*
Drive screw
** Lag bolt
*** With minimum safety factor of 5
Fastener schedule per NFPA

36

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 9/1/2006

Fig. 120MJ - Mutt & Jeff U Hanger


Size Range Size 3/4" thru 8" pipe
Material Carbon Steel
Function Used to support piping from wood beams where no
contraction is expected. Used extensively in automatic fire sprinkler
systems. The Mutt & Jeff is used when the wood beam is on a
diagonal.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless
Steel materials.
Order By Figure number, pipe size, side length and finish

Fig. 120W - Wrap Around U Hanger


Size Range Size 3/4" thru 2" pipe
Material Carbon Steel
Function Required for automatic fire protection agencies
to be used on the end of branch lines to prevent pipe from whipping
vertical and striking ceiling or beam
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless
Steel materials.
Order By Figure number, pipe size, length and finish

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

37

www.tolco.com
Revision 6/9/2008

Fig. 120RWA (Model B)


Retrofit Wrap Around U-Hanger Clamp

Component of State of
California OSHPD Approved
Seismic Restraints System

Size Range 1" thru 8" pipe


Material Carbon Steel
Function Clamp Model B is designed to restrain movement
of the pipe within standard U-hangers as is required by NFPA
13. Where retrofit capability is crucial, the Fig. 120RWA is a
labor efficient alternative to the standard TOLCO Fig. 120W
Wrap Around U-Hanger.
Features Installs easily by tightening two hex nuts. Features
a unique bracing slot that locks onto a standard U-hanger to
become a solid unit that will stabilize the pipe during seismic
activity or sprinkler head activation. Designed to be used in retrofit or new construction applications. Will clamp to existing
U-Hangers without restriction to leg angle
Approvals Underwriters' Laboratories listed in the USA (UL)
and Canada (cUL) as a restrainer. Included in our Seismic
Restraints Catalog approved by the State of California Office
of Statewide Health Planning and Development (OSHPD). For
additional load, spacing and placement information relating to
OSHPD projects, please refer to the TOLCO Seismic Restraint
Systems Guidelines. NFPA 13 (1999) A-6-2.3.3.
Finish Plain and Galvanized. Consult factory for Stainless
Steel material.
Order By Figure number, type numbers and pipe size
Ordering Note Order by the following type and pipe size:
Type 1 (1" and 114" pipe size)
Type 2 (112" and 2" pipe size)
Type 3 (212" and 3" pipe size)
Type 4 (4" pipe size)
Type 6 (5" and 6" pipe size)
Type 8 (8" pipe size)
Important Note The bracing slot feature is sized to fit the UHanger rod schedule as required by NFPA 13 as follows:
5/16" rod for up to 2" pipe
3/8" rod for 212" - 6" pipe
1/2" rod for 8" pipe
For other rod size requirements consult factory.

38

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 130 - Beam Clamp with Bolt and Nut


Size Range Fig. 130-1 = TJI 35
Fig. 130-2 =
Fig. 130-3 = TJI 25
Fig. 130-4 = TJI 55 & 65
Fig. 130-5 = TJI 75
Fig. 130-6 = TJI 96
Material Carbon Steel
Function Effective and economical method of hanging from
Trus Joist type beams. Use with Fig. 102 Eye Rod.
Approvals Sizes 1, 2, 3 and 4 Underwriters Laboratories
listed in the USA (UL) and Canada (cUL) listed through 4"
pipe. All Fig. 130 Beam Clamps meet requirements of Factory
Mutual Engineering and NFPA 13, through 4" pipe.
Finish Electro-Galvanized
Note Available in HDG finish or Stainless Steel materials.
Order By Figure number with dash designation and finish or
by height and width of beam and finish.

Dimensions Weights
Size
130-

1
2
3
4
5
6

314
312
314
312
358
412

Beam Dimensions
H
W
112
134
112
112
134
212

2516
212
134
312
312
378

Approx.
Wt./100
65
70
58
83
86
101

* Max. Rec. Load 500 lbs.


**Safety Factor of 5
Larger bolts and I-rods are required for 5" and 6" pipe sizes

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

39

www.tolco.com
Revision 3/1/2008

Fig. 150 - Wing-It Concrete Deck Insert


Size Range 3/8" through 7/8".
Material Carbon Steel with plastic vinyl thread protector.
Function For use in metal deck formed concrete, to attach hanger
rods or seismic bracing attachments; Allows for pre-positioning of
anchor in poured concrete decks.
Features Fast attach to various size and shaped holes, all steel solid
secure attachment, narrow diameter allows closer placement, can be
converted to steel stud for flush mount applications such as seismic
bracing attachments.
Approvals Included in our (OSHPD) Pre-Approved Seismic Bracing
Guidelines for 2008, U.L. Listed; 3/8" up to 4" pipe size, 1/2" up to 8"
pipe size. Factory Mutual Approved; 3/8" up to 4" pipe size, 1/2" up to
8" pipe size.
Finish Electro-Galvanized.
Order By Figure number and size.

Dimensions Loads
Anchor
Size

Anchor
Location
On Flute

Embed.
Depth

Min.
Insert
Spacing

Min.
Edge
Distance

Tension
Load
T allow*

Shear
Load
V allow*

8"
8"
1
2"
1
2"
5
8"
5
8"
3
4"
3
4"
7
8"
7
8"

Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower

2"
2"
2"
2"
2"
2"
2"
2"
2"
2"

412"
412"
6"
6"
712"
712"
9"
9"
1012"
1012"

12"
12"
12"
12"
12"
12"
12"
12"
12"
12"

935
705
980
705
1030
705
1080
705
1135
705

940
940
1330
1330
1330
1330
1330
1330
1330
1330

3
3

* T actual + V actual < 1.2


T allow
V allow

40

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 3/1/2008

Fig. 200 - Trimline Adjustable Band Hanger


Size Range 1/2" thru 8" pipe
Material Carbon Steel, Mil. Galvanized to G90
specifications
Function For fire sprinkler and other general piping
purposes. Knurled swivel nut design permits hanger
adjustment after installation.
Features
(1/2" thru 2") Flared edges ease installation for
all pipe types and protect CPVC plastic pipe from
abrasion. Captured design keeps adjusting nut
from separating with hanger. Hanger is easily
installed around pipe.
(212" thru 8") Spring tension on nut holds it
securely in hanger before installation. Adjusting
nut is easily removed.
Approvals Underwriters Laboratories listed (1/2"
thru 8") in the USA (UL) and Canada (cUL) for steel
and CPVC plastic pipe and Factory Mutual Engineering
Approved (3/4" thru 8"). Conforms to Federal
Specifications WW-H-171E, Type 10 and Manufacturers
Standardization Society SP-69, Type 10.
Maximum Temperature 650F
Finish Mil. Galvanized. For Stainless Steel materials, order TOLCO Fig. 200WON.
Order By Figure number and pipe size
Note For removable nut feature, order Fig. 200 S

Dimensions Weights
Pipe
Size
1/2
3/4
1
114
112
2
212
3
312
4
5
6
8

Rod Size
Inch
Metric
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
1/2
1/2
1/2

8mm
8mm
8mm
8mm
8mm
8mm

or
or
or
or
or
or

10mm
10mm
10mm
10mm
10mm
10mm
10mm
10mm
10mm
10mm
12mm
12mm
12mm

318
318
338
334
378
412
558
578
738
738
918
1018
1318

258
212
258
278
278
3
418
4
514
5
614
634
834

Max. Rec.
Load Lbs.
400
400
400
400
400
400
600
600
600
1000
1250
1250
1250

Approx.
Wt./100
11
11
12
13
14
15
27
29
34
35
66
73
136

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

41

www.tolco.com
Revision 4/30/2008

Fig. 200H - Heavy Duty Band Hanger (for Trapeze)


Size Range 2" thru 4" trapeze pipe size.
Used to support up to 8" pipe. For 6" and 8"
trapeze pipe, consult factory.
Material Carbon Steel Pre-Galvanized to
G40 Spec
Function Designed primarily to support
substantially heavier loads than is normally
intended for the nominal hanger size. Used
extensively to support trapeze installations
and the increased loads from both above and
below the trapeze assembly.
Features Furnished with 3/8" or 1/2"
adjusting threaded ring nut.
Approvals Underwriters Laboratories
listed in the USA (UL) and Canada
(cUL). Conforms to Federal Specification
WW-H-171E, Type 10 and Manufacturers
Standardization Society SP-69, Type 10.
Maximum Temperature 650F
Finish Pre-Galvanized
Order By Figure number, pipe size and rod
size.
Important Design Note Because of the
increased loads applied to the trapeze assembly, both the upper trapeze supports as well
as the lower hanging unit must be able to hold
the maximum loads intended.
B

Dimensions Weights
Trapeze
Pipe Size

Rod Size
Size

Max. Rec.
Load Lbs.

2
2
212
212
3
3
4
4

3/8
1/2
3/8
1/2
3/8
1/2
3/8
1/2

4916
42332
5516
51532
534
578
678
7132

3732
338
32332
378
32732
33132
4716
41932

1250
1250
1250
1250
1250
1250
1250
1250

* Select trapeze pipe size based on section modulus required for span of
trapeze per information provided in NFPA 13 (2002) Table 9.1.1.6.1 (a and b).
** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13.

42

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 1/24/2007

Fig. 200WON - Trimline Adjustable Band Hanger w/o Swivel Nut


Size Range 1/2" thru 8" pipe
Material Carbon Steel
Function Recommended for the suspension of fire
sprinkler and non-insulated pipe or insulated pipe with
Fig. 220 shield. Generally installed with two hex nuts.
Features Flared edges on sizes 1/2" thru 2". Eases
installation and protects CPVC pipe from any abrasion.
Approvals Underwriters Laboratories listed
(1/2" thru 8") in the USA (UL) and Canada (cUL) for
steel and CPVC plastic pipe. Conforms to Federal
Specifications WW-171E, Type 7 and Manufacturers
Standardization Society SP-69, Type 7
Maximum Temperature 650F
Finish Mil. Galvanized to G-90
Note Available in Stainless Steel materials
Order By Figure number and pipe size

Dimensions Weights
Pipe
Size

Rod Size
A

Max. Rec.
Load Lbs.

Approx.
Wt./100

1/2
3/4
1
114
112
2
212
3
312
4
5
6
8

3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
1/2
1/2
1/2

212
212
278
338
312
334
518
538
634
634
838
938
1238

2
2
218
212
212
212
358
312
458
412
512
6
8

400
400
400
400
400
400
600
600
600
1000
1250
1250
1250

8
8
9
10
11
12
24
27
32
33
60
68
130

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

43

www.tolco.com
Revision 5/5/2008

Fig. 800 - Adjustable Sway Brace Attachment to Steel


Size Range 4" thru 18" beam width
Material Carbon Steel
Function Seismic brace attachment to steel.
Features This products design incorporates a concentric attachment
point which is critical to the performance of structural seismic connections.
NFPA 13 indicates the importance of concentric loading of connections
and fasteners. Permits secure connection to steel where drilling and/or
welding of brace connection could present structural issues.
Installation Instructions The Fig. 800 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to
be combined with a TOLCO transitional attachment, "bracing pipe" and a
TOLCO "braced pipe" attachment to form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install Place the Fig. 800 on the steel beam, tighten the cone point
set bolts on flange until bolt heads break off. Tighten hex head bolts into
clamp body until lock washers are fully flat. Attach other TOLCO transitional attachment fittings, Fig. 909, 910 or 980. Transitional fitting attachment can pivot for adjustment to proper brace angle.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in
our Seismic Restraints Catalog approved by the State of California Office
of Statewide Health Planning and Development (OSHPD). For additional
load, spacing and placement information relating to OSHPD projects,
please refer to the TOLCO Seismic Restraint Systems Guidelines.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, type number and size number.

Component of State of
California OSHPD Approved
Seismic Restraints System

Dimensions Weights
Max. Design Loads/Lbs. (cULus)

*Max. Design Loads/Lbs. (FM)

Size

Fits Beam
Range (In.)

Along
Beam

Across
Beam

Along
Beam

Across
Beam

1
2
3
4
5
6
7

4-6
6-8
8 - 10
10 - 12
12 - 14
14 - 16
16 - 18

1265
1265
1265
1265
1265
1265
1265

2015
2015
2015
2015
2015
2015
2015

2800
2800
2800
2800
2800
2800
2800

2800
2800
2800
2800
2800
2800
2800

Dimensions Weights
Max. Design Loads/Lbs. (cULus)

Flange Thickness
Type
Max. (In.)
1
2

3/4
114

*Max. Design Loads/Lbs. (FM)

Along
Beam

Across
Beam

Along
Beam

Across
Beam

1265
1265

2015
2015

2800
2800

2800
2800

* Load shown is allowable with brace installed, between 30 - 90. No reduction of load based
on brace angle is required.
TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind,
including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

44

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/22/2008

Fig. 825 - Bar Joist Sway Brace Attachment

Component of State of
California OSHPD Approved
Seismic Restraints System

Size Range One size accommodates all TOLCO Fig. 900 Series sway brace
attachments. Maximum Horizontal Design Load 2015 lbs.
Material Carbon Steel
Function To attach sway bracing and hanger assemblies to steel open web
structural members.
Features This products design incorporates a concentric attachment point which
is critical to the performance of structural seismic connections. NFPA 13 indicates
the importance of concentric loading of connections and fasteners. Permits secure
non-friction connection without drilling or welding. Unique design reinforces point of
connection to joist. Break off head bolt design assures verification of proper installation torque (min. 31 ft.-lbs.).
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).
Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints
Catalog approved by the State of California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and placement information
relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems
Guidelines.
Maximum Design Load 2015 Lbs.
Installation Instructions The Fig. 825 is the structural attachment component
Weight/100 237.5 Lbs.
of a longitudinal or lateral sway brace assembly. It is intended to be combined
UL Listed as Hanger Attachment
with a TOLCO transitional attachment, "bracing pipe" and a TOLCO "braced pipe"
attachment, to form a complete bracing assembly. NFPA 13 and/or OSHPD guide6" Pipe Max.
lines should be followed.
FM Approved Design Loads*
To Install Place the Fig. 825 on the steel beam, tighten the cone point set bolts
2900 - Across Beam
until bolt heads break off. Attach other TOLCO transitional attachment fitting, Fig.
1350 - Along Beam
909, 910 or 980. Transitional fitting attachment can pivot for adjustment to proper
brace angle.
Important Structural Note:
The TOLCO Fig. 825 has significant UL
established design loads, however, structural issues related to the steel joist member
require restricted location installation for all
bracing. Steel Joist Manufacturers require
that all earthquake bracing connections be
within 6" of the cord panel point. Installation
of the Fig. 825 must be limited to the outer
third sections of the joist span. For installations within the center third section of the
joist span, use UL Listed TOLCO Fig. 825A.
Finish Plain, Electro-Galvanized and HDG
Order By Figure number and finish
US Patent #6,098,942, Canada Patent
#2,286,659

* Load shown is allowable with brace installed,


between 30 - 90. No reduction of load based
on brace angle is required.

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind,
including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.
OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

45

www.tolco.com
Revision 12/10/2007

Fig. 825A - Bar Joist Sway Brace Attachment


Size Range One size accommodates all TOLCO Fig. 900 Series sway
brace attachments. Maximum Horizontal Design Load 1265 lbs.
Material Carbon Steel
Function To attach sway bracing to steel open web structural members.
Features This products design incorporates a concentric attachment
point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without
drilling or welding. Unique design reinforces point of connection to joist.
Break off head bolt design assures verification of proper installation.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL). For additional load, spacing and placement information
relating to OSHPD projects, please refer to the TOLCO Seismic Restraint
Systems Guidelines.
Installation Instructions The Fig. 825A is the structural attachment
component of a longitudinal or lateral sway brace assembly. It is intended
to be combined with a TOLCO transitional attachment, "bracing pipe"
and a TOLCO "braced pipe" attachment to form a complete bracing assembly.
NFPA 13 and/or OSHPD guidelines should be followed.
To Install Place the Fig. 825A
on the steel beam, tighten the cone
point set bolts until bolt heads break
off. Attach other TOLCO transitional
attachment fitting, Fig. 909, 910 or 980.
Transitional fitting attachment can pivot
for adjustment to proper brace angle.
Important Structural Note:
The TOLCO Fig. 825A has significant
UL established design loads, however,
structural issues related to the steel
joist member require restricted location
installation for all bracing. Steel Joist
Manufacturers require that all earthquake bracing connections be within
6" of the cord panel point. Installation
of the Fig. 825A is not restricted to
the two outer third sections of the
joist. For greater design loads, refer to
TOLCO Fig. 825.
Finish Plain
Order By Figure number and finish

Maximum Design Load 1265 Lbs.

Patent #6,098,942

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

46

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 906 - Sway Brace Multi-Fastener Adapter

Size Range Use with 1" and 114" TOLCO UL listed Fig. 900 Series Earthquake Brace Attachments.
Material Carbon Steel
Application Allows sway brace fittings to develop greater load carrying ability by providing multiple fastener
attachments. The National Fire Protection (NFPA) provides
information on fastener loads to various structures. Refer to
NFPA 13 (2002), Figure 9.3.5.9.1.
Approvals Underwriters Laboratories Listed in the USA
(UL) and Canada (cUL) only when used with TOLCO 900
Series Earthquake Brace Attachments. Included in our
Seismic Restraints Catalog approved by the State of California
Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO
Seismic Restraint Systems Guidelines.
Installation Instructions The Fig. 906 is a multiple fastener
structural attachment component of a longitudinal or lateral
sway brace assembly. It is intended to be combined with a
TOLCO transitional attachment, "bracing pipe" and a TOLCO
"braced pipe" attachment to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed.
To Install Attach the Fig. 906 to the structural surface as
per fastener design guidelines. Attach other TOLCO transitional attachment fitting Fig. 909, 910 or 980. Transitional
fitting attachment can pivot for adjustment to proper brace
angle.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless Steel materials.
Order By Figure number and specify dimensions H1 and H2.

Dimensions Weights
A

H1

H2

Approx.
Wt./100

12

1/4

Specify

Specify

Varies

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

47

www.tolco.com
Revision 12/10/2007

Fig. 907 - 4-Way Longitudinal Sway Brace Attachment


Size Range 1" x 1", 1" x 114" and 114" x 114" bracing pipe.
Material Carbon Steel, hardened cone (or cup) point engaging screw
Function For bracing pipe against sway and seismic disturbances, Functions as
a longitudinal brace connection when attached to a lateral brace pipe. Bracing connection must be positioned as close as physically possible to the braced pipe (No
more than 3" away). Must be used only with TOLCO bracing components. When
used in conjunction with TOLCO Fig. 1000, this combination bracing restricts piping
movement in tension and compression both laterally and longitudinally.
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).
Included in our Seismic Restraints Catalog approved by the State of California Office
of Statewide Health Planning and Development (OSHPD). For additional load,
spacing and placement information relating to OSHPD projects, please refer to the
TOLCO Seismic Restraint Systems Guidelines.
Installation Instructions The Fig. 907 is a transitional component of a longitudinal 4-way sway brace assembly. It is intended to be installed with the longitudinal
and lateral "bracing pipes", TOLCO structural attachment fittings, Fig. 909, 910 and
980 and the Fig. 1000 TOLCO "braced pipe" fitting, to form a complete bracing
assembly. NFPA 13 and/or OSHPD guidelines should be followed.
To Install Attach the Fig. 907 over the lateral "bracing pipe" to within 3" of its
position relative to the "braced pipe" connection. Adjust brace angle and tighten
bolts until heads bottom out on surface.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, bracing pipe sizes and finish.

Component of State of
California OSHPD Approved
Seismic Restraints System

Dimensions Weights
Pipe Size

Max. Design
Load Lbs.*

Approx.
Wt./100

1x1
1 x 114
114 x 114

434
5116
538

434
41316
514

655*
655*
655*

103
107
109

* Load will accommodate up to 4" pipe at maximum spacing.

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

48

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 909 - No-Thread Swivel Sway Brace Attachment


Component of State of
Size Range 1" bracing pipe. For brace pipe sizes larger than 1",
California OSHPD Approved
use TOLCO Fig. 980.
Seismic Restraints System
Material Carbon Steel, hardened cone point engaging screw
Function The structural component of a sway and seismic bracing
system.
Features This products design incorporates a concentric
attachment opening which is critical to the performance of structural
seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clearly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows
for easy inspection of pipe engagement.
Application Note The Fig. 909 is used in conjunction with the
TOLCO Fig. 1000, Fig. 1001, or Fig. 4 (A) pipe clamp, and joined
together with bracing pipe. Sway brace assemblies are intended to
be installed in accordance with NFPA 13 (or TOLCO State of California
OSHPD Approved Seismic Restraint Manual) and the manufacturers installation instructions. The required type, number and size of
fasteners used for the structure attachment fitting shall be in accordance with NFPA 13 and/or OSHPD.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Included in our Seismic Restraints Catalog
approved by the State of California Office of Statewide Health
Planning and Development (OSHPD). For additional load, spacing
and placement information relating to OSHPD projects, please refer
to the TOLCO Seismic Restraint Systems Guidelines.
Installation Instructions The Fig. 909 is the structural or transitional attachment component of a longitudinal or lateral sway brace
assembly. It is intended to be combined with the "bracing pipe"
and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 4B or
4L to form a complete bracing assembly. NFPA 13 and/or OSHPD
guidelines should be followed.
To Install Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface.
Attachment can pivot for adjustment to proper brace angle.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, pipe size and finish.

Dimensions Weights
Pipe Size

Hole Size Max. Design.


B
H*
Load Lbs.
158

17/32

Max. Design Load


Lbs. w/Washer

Approx.
Wt./100

2765

91

2015

* Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory.

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.
OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

49

www.tolco.com
Revision 12/10/2007

Fig. 910 - Swivel Sway Brace Fitting


Size Range 1" and 114" bracing pipe. For brace pipe sizes larger than 11/4", use
TOLCO Fig. 980.
Material Carbon Steel
Function For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; the
Fig. 910 is used in conjunction with the Fig. 1001, Fig. 1000 or with a Fig.
4A Pipe Clamp and joined together with a brace pipe per NFPA 13.
Features This products design incorporates a concentric attachment
opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates that fastener table load
values are based only on concentric loading. Universal swivel design
allows Fig. 910 to be attached at any surface angle.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL). Included in our Seismic Restraints Catalog approved by
the State of California Office of Statewide Health Planning and
Development (OSHPD). For additional load, spacing and placement
information relating to OSHPD projects, please refer to the TOLCO
Seismic Restraint Systems Guidelines.
Installation Instructions The Fig. 910 is a structural or transitional
attachment component of a longitudinal or lateral sway brace assembly. It
is intended to be combined with the "bracing pipe", and TOLCO "braced
pipe" attachment, Fig. 1000, 1001, 4A, 4B or 4L to form a complete
bracing assembly. Follow NFPA 13 and/or OSHPD guidelines.
To Install Thread the pipe into the Fig. 910 until pipe threads
are visible through inspection site hole. Attachment can pivot for
adjustment to proper brace angle.
Note The Fig. 910 Swivel Attachment and the Fig. 1001, Fig.
1000, or Fig. 4A Pipe Clamp make up a sway brace system of
(UL) Listed attachments and bracing materials which satisfies
the requirements of Underwriters Laboratories and the National
Fire Protection Association (NFPA).
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, pipe size and finish.

Component of State of
California OSHPD Approved
Seismic Restraints System

Lateral Brace

Dimensions Weights
Pipe Size

Hole Size
D

Max. Design
Load Lbs.

Approx.
Wt./100

1
114

2
1316

112
1516

3
3

9/16
9/16

2516
2516

2
2516

2015
2015

88
99

NOTE - Available with hole sizes to accommondate up to 3/4" fastener. Consult factory.

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

50

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 975 - Straight Sway Brace Fitting


Size Range 1" bracing pipe. For brace pipe sizes larger than 1", use
TOLCO Fig. 980.
Material Carbon Steel
Function For bracing pipe against sway and seismic disturbances. The
building attachment component of a sway brace system; the
Fig. 975 is used in conjunction with the Fig. 1000, Fig. 1001 or with
a Fig. 4A Pipe Clamp and joined together with a brace pipe per
NFPA 13.
Features Open design allows for easy checking of thread engagement.
Approvals Underwriters Laboratories Listed in the USA (UL) and
Canada (cUL).
Installation The Fig. 975 is the structural or transitional attachment component of a longitudinal or lateral sway bace assembly. It is intended to be
combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig.
1000, 1001, 4A, 4B or 4L to form a complete bracing assembly. NFPA 13 and/
or OSHPD guidelines should be followed.
To Install Thread the Fig. 975 onto the threaded bracing pipe.
Attachment can pivot for adjustment to proper brace angle. (Bending of plate
not permitted.)
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless
Steel materials.
Order By Figure number and finish.
Note Bending of this fitting alters the material strength. Use Fig.
909 or Fig. 910 when angle fitting is required.

Lateral Brace
Dimensions Weights
Pipe Size

Hole
Size

Max. Design
Load Lbs.

Approx.
Wt./100

312

112

9/16

2015

88

NOTE - Available with hole sizes to accommondate up to 3/4" fastener. Consult factory.

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

51

www.tolco.com
Revision 6/13/2008

Fig. 980 - Universal Swivel Sway Brace Attachment


Size Range One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all
structural steel up to 1/4" thick.
Component of State of
Material Carbon Steel
California OSHPD Approved
Function Multi-functional attachment to structure or
Seismic Restraints System
braced pipe fitting.
Features This products design incorporates a concentric attachment opening which is critical to the performance
H
of structural seismic connections. NFPA 13 (2002) Figure
9.3.5.9.1 indicates clearly that fastener table load values are
based only on concentric loading. Mounts to any surface
angle. Break off bolt head assures verification of proper
installation.
Installation The Fig.980 is the structural or transitional
A
attachment component of a longitudinal or lateral sway
brace assembly. It is intended to be combined with the
B
"bracing pipe" and TOLCO "braced pipe" attachment, Fig.
1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing
assembly. NFPA 13 and/or OSHPD guidelines should be
followed.
To Install Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off.
Attachment can pivot for adjustment to proper brace angle.
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual
Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office
of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information
relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines.
Note The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000 , Fig. 2001 or Fig. 4A Pipe Clamp make up a
sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters
Laboratories and the National Fire Protection Association (NFPA)
Finish Plain
Note Available in Electro-Galvanized finish.
Order By Figure number and finish.
PATENT #6,273,372

Lateral Brace

Dimensions Weights
A

H*

Max. Design
Load Lbs.
(cULus)

**Max. Design
Load Lbs.
(FM)

Approx.
Wt./100

514

178

17/32

2765

2800

132

* Available with hole sizes to accommodate up to 3/4" fastener. Consult factory.


** Load shown is allowable with brace installed, between 30 - 90. No reduction of load based on
brace angle is required.

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

52

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 981 - Fast Attach Universal Swivel Sway Brace Attachment


Component of State of

Size Range One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel,
California OSHPD Approved
Seismic Restraints System
and all structural steel up to 1/4" thick.
Material Carbon Steel
Function Multi-functional attachment to hanger rod, trapeze rod,
structure or braced pipe fitting.
Features Fits multiple sizes of bracing pipe, strut or structural
steel. Swivel allows adjustment to various surface angles. Breakaway bolt head assures verification of proper installation torque.
Unique fast attach yoke design allows Fig. 981 to be installed using
hanger rods 3/8" through 3/4" in size. Stackable design allows
installation of both lateral and longitudinal braces, as well as opposing
braces, to be easily installed on a single hanger rod, with no disassembly. The retrofit yoke has a visual verification of proper installation
torque. Tighten existing hex nut down until the slight gap in the yoke assembly closes completely.
Installation The Fig. 981 is the braced pipe attachment component of a lateral or longitudinal brace assembly.
It is intended to be combined with the pipe hanger, all-thread rod, bracing pipe and TOLCO transitional and
structural attachment component(s) to form a complete bracing assembly. NFPA 13 and or OSHPD guidelines
should be followed.
To Install Spin nut on top of hanger counterclockwise to loosen the nut and raise it above the top of the hanger.
Attach Fig. 981 by slipping the open side of the 981 yoke onto the all thread rod above the top of the hanger. Be
sure that the concave indented side of the Fig. 981 yoke is facing upward away from the top of the hanger toward
the loosened hex net. Spin the hex nut clockwise and tighten securely. Insert brace pipe into the jaw of the 981 and
tighten the cone point set bolt until the hex head breaks off ensuring proper installation torque. Pivot brace pipe to
proper angle and attach to structure using a TOLCO swivel structural attachment
Approvals Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) for steel and CPVC pipe.
Included in our Seismic Restraint Systems Guidelines, approved by the California Office of Statewide Health Planning
and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO
Seismic Restraint Systems Guidelines.
Finish Electro-Galvanized
Order By Figure number, rod size 3/8" thru 3/4" and finish.
Pat. # 6,273,372, Pat. # 7,097,141

Dimensions Weights
A

Max. Design
Load Lbs.

Approx.
Wt./100

518

418

114

214

2015

88

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

53

www.tolco.com
Revision 12/10/2007

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 990 - Cable Sway Brace Attachment


Size Range 1/8", 3/16" and 1/4" pre-stretched cable. 3/8" thru 114"
hanger rod bolt or fastener.
Material Carbon Steel
Function Cable attachment for sway bracing. Attaches sway brace to
structure or to hanger. To be used with 7 x 19 strand core pre-stretched
galvanized aircraft cable.
Features Cable easily slides into oversized front arch opening.
Breakaway hex nuts assure verification of proper installation. Will mount
to any surface angle.
Approvals Included in our Seismic Restraints Catalog approved by the
State of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating
to OSHPD projects, please refer to the TOLCO Seismic Restraint System
Guidelines.
Finish Electro-Galvanized
Order By Figure number, cable size and mounting hole size.
Note Order 990H for hanger rod, bolt or fastener hole size 1" thru 114".

Dimensions Weights
Cable
Diameter

1/8"
3/16"
1/4"

4516
5
5

2
214
258

Maximum Design
Load Lbs.
975*
2050*
3150*

* Maximum load rating controlled by cable breaking strength.

54

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 12/10/2007

Fig. 991 - Fast Attach Cable Sway Brace Attachment


Size Range 1/8", 3/16" and 1/4" pre-stretched cable. Fits rod size 3/8" thru
3/4".
Material Carbon Steel
Function Cable attachment for sway bracing. Attaches sway brace to hanger
rod. To be used with 7 x 19 strand core pre-stretched galvanized aircraft cable.
Features Fits multiple sizes of cable. Cable easily slides into
oversized front arch opening. Swivel allows adjustment to various
surface angles. Break-away hex nuts assure verification of proper
installation torque. Unique Fast-Attach yoke design allows Fig. 991 to be
installed using hanger rods 3/8" through 3/4" in size. Stackable design allows
installation of both lateral and longitudinal braces, as well as opposing braces, to
be easily installed on a single hanger rod, with no disassembly. The retrofit yoke
has a visual verification of proper installation torque. Tighten existing hex nut down
until the slight gap in the yoke assembly closes completely.
Approvals Included in our Seismic Restraints Catalog approved by the State
of California Office of Statewide Health Planning and Development (OSHPD). For
additional load, spacing and placement information relating to OSHPD projects,
please refer to the TOLCO Seismic Restraint System Guidelines.
Finish Electro-Galvanized
Order By Figure number, rod size 3/8" through 3/4"
Pat. # 7,097,141

Component of State of
California OSHPD Approved
Seismic Restraints System

Dimensions Weights
Cable
Diameter

1/8
3/16
1/4

534
634
634

218
212
212

Maximum Design
Load Lbs.
975*
2050*
3150*

* Maximum load rating controlled by cable breaking strength.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

55

www.tolco.com
Revision 5/27/2008

Component of State of
California OSHPD Approved
Seismic Restraints System

Fig. 1000 - Fast Clamp Sway Brace Attachment


Size Range Pipe size to be braced: 1" thru 6" Schedule
10 thru 40 IPS.* Pipe size used for bracing: 1" and 114" Schedule 40
IPS.
* Additionally (UL) approved for use to brace Schedule 7
sprinkler pipe up to 4" (maximum horizontal design load
655 lbs.) Torque requirement 6 8 ft. lbs.
Material Carbon Steel
Function For bracing pipe against sway and seismic
disturbance. The pipe attachment component of a sway brace system: Fig. 1000 is used in conjunction with a TOLCO
Fig. 900 Series Fitting and joined together with bracing pipe per
NFPA 13* or TOLCO OSHPD Approved Seismic Manual,
forming a complete sway brace assembly.
Features Field adjustable, making critical pre-engineering of
bracing pipe unnecessary. Unique design requires no threading of
bracing pipe. Can be used as a component of a 4-way riser brace.
Can be used as longitudinal brace with Fig. 907. Comes assembled
and individually packaged with illustrated installation instructions
sizes are clearly marked. Steel leaf spring insert provided to
assure installer and inspector necessary minimum torque has been
achieved.
Installation The Fig. 1000 is the "braced pipe" attachment
component of a lateral sway brace assembly. It is intended to be
combined with the "bracing pipe" and TOLCO structural attachment component, Fig. 980, 910 or 909 to form a complete bracing
assembly. Follow NFPA 13 and/or OSHPD guidelines.
To Install Place the Fig. 1000 over the pipe to be braced, insert
bracing pipe through opening leaving a minimum of 1" extension.
Brace pipe can be installed on top or bottom of pipe to be braced.
Tighten hex nuts until leaf spring is flat. It is recommended that the
brace angle be adjusted before hex nuts are fully tightened.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Approved by Factory Mutual Engineering (FM).
Included in our Seismic Restraints Catalog approved by the State
of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic
Restraint Systems Guidelines.
Application Note Position Fast Clamp and tighten two hex nuts
until leaf spring flattens. A minimum of 1" pipe extension beyond
the Fig. 1000 is recommended.
Finish Plain
Note Available in Electro-Galvanized and HDG finish or Stainless
Steel materials.
Order By Order first by pipe size to be braced, followed by pipe
size used for bracing, figure number and finish.

Maximum Design Load


1" thru 4" pipe size 2015 lbs.
6" size 1265 lbs.
FM Approved Design Loads*
1" - 2" - 600 lbs.
3" - 4" - 700 lbs.

Lateral Brace

TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance
that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.

56

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/22/2008

Fig. 1001 - Sway Brace Attachment


Size Range Pipe size to be braced: 212" thru 8" IPS.* Pipe size
used for bracing: 1" and 114" Schedule 40 IPS.
Material Carbon Steel
Function For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system:
The Fig. 1001 is used in conjunction with a TOLCO 900 Series fitting
and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly.
Features Can be used to brace schedules 7 through 40 IPS.
Field adjustable, making critical pre-engineering of bracing pipe
length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace.
Comes assembled and ready for installation. Fig. 1001 has built-in
visual verification of correct installation. See installation note below.
Installation Note Position Fig. 1001 over the pipe to be braced
and tighten two hex head cone point set bolts until heads bottom
out. A minimum of 1" pipe extension is recommended. Brace pipe
can be installed on top or bottom of pipe to be braced.
Approvals Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Approved by Factory Mutual Engineering (FM).
Included in our Seismic Restraints Catalog approved by the State
of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement information
relating to OSHPD projects, please refer to the TOLCO Seismic
Restraint Systems Guidelines.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Indicate pipe size to be braced followed by pipe size
used for bracing, figure number and finish.
Important Note The Fig. 1001 is precision manufactured to
perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires
that the Fig. 1001 must be used only with other TOLCO bracing
products. The Fig 1001 is not intended for use with the Fig. 907
4-Way Longitudinal Brace Attachment.
US AND INTERNATIONAL PATENT APPLICATION IN PROCESS

Component of State of
California OSHPD Approved
Seismic Restraints System

Maximum Design Load


Sch. 7 - 1600 lbs.
Sch. 10 & 40 w/1" Brace Pipe - 2015 lbs.
Sch. 10 & 40 w/114" Brace Pipe - 2765 lbs.
FM Approved Design Loads*
2" - 2400 lbs.
3" - 4" - 2500 lbs.
5" - 8" - 1500 lbs.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

57

www.tolco.com
Revision 12/10/2007

Fig. 2002 - Sway Brace Attachment


Size Range Pipe size to be braced: 212" thru 8" all steel
schedules, copper, plastic, FRP, cast iron and ductile iron.
Consult factory when bracing other than steel. The Fig. 2002
accepts brace pipes sizes 112" and 2" steel schedule 100
through schedule 40.
Material Carbon Steel
Function For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: The Fig. 2002 is used in conjunction with a TOLCO 900
Series sway brace attachments and joined together with bracing pipe. Install per NFPA 13 and/or TOLCO State of California
OSHPD Approved Seismic Restrain Manual.
Features Unique design will not damage thin wall, plastic,
copper or ductile iron pipe. Easy verification of proper installation by tightening bolts until ears touch.
Installation Place Fig. 2002 over pipe to be braced. Slide
bracing pipe through attachment and tighten hex nuts until ears
touch.
Approvals Underwriters Laboratories Listed in the USA
(UL) and Canada (cUL). Included in our Seismic Restraints
Catalog approved by the State of California Office of Statewide
Health Planning and Developoment (OSHPD). For additional
load, spacing and placement information relating to OSHPD
projects, please refer to the TOLCO Seismic Restraint Systems
Guidelines.
Finish Plain
Note Available in Electro-Galvanized and HDG finish.
Order By Figure number, pipe size to be braced, pipe size
used for bracing (112" or 2") and finish.
Important Note The Fig. 2002 is precision manufactured
to perform its function as a critical component of a complete
bracing assembly. To ensure performance, the UL Listing
requires that the Fig. 2002 must be used only with other
TOLCO bracing products.

58

Component of State of
California OSHPD Approved
Seismic Restraints System

Maximum Design Load 2015 Lbs.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/24/2001

Reference
Material
Included in our Seismic Restraints Catalog
approved by the State of California Office of
Statewide Health Planning and Development
(OSHPD). For additional load, spacing and
placement information relating to OSHPD
projects, please refer to the TOLCO Seismic
Restraint Systems Guidelines.

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

59

www.tolco.com
Revision 1/24/2007

TOLCO Cross Reference Chart

60

TOLCO

GRINNELL
& ANVIL

B-LINE

ERICO

PHD

SUPER STRUT

CARPENTER
& PATERSON

EMPIRE
INDUSTRIES

1
1A
1CBS
1C.I.
1F
1LD
1LDF
1PVC
1LDPVC
1V
2
2F
2FWON
2WON
3
3F
4
4A
4B
4C.I.
4F
4H
4L
4PVC
5
6
6F
6PVC
7
8
9
9X
14
14X
20
20S
21
21F
22
23
24
25
28
30
30L
30M
30H
31-M
31-O
32
33
34
35
40
41
42

260
300

590

65

67

212
212FP

216

295
261

103
100
600
599
595
594
262

194

195
199

47
49
52

B3100
B3108

B3102
B3100F
B3104
B3104F
B3100C
B3104C
B3106
B3170
B3170NFF
B3172F
B3172
B3690
B3690F
B3140

B3142

B3144
B3373

B3373C
B3148
B3149
B3132
B3132W
B3134
B3134W
B3180
B3256

B3068

B3066
B3067

B3147
B3084
B3086
B3085
B3190
B3191

400
415

405
400FL
410
410FL
420

100
100FL

105
418
418FL
450

451

452
510

520
700
705
517
516

8EG

107
108
109

348
351
352
353

712
373
374
374A
457
458
319

450
430

420
450F
440
440F
453

450V
151
151F
180F
180
970
97-F
520

522

525
550

553
535
545
580
585
590
595
825
830

850
855
860

840

904
903
820
810
910

C710
CX710

CI1710
C710F
CL710

C710P

C727
C727F
C725
C727
C711
C711F
C725

C726
C720

C720P
C720L
CX725
C724
W724

164

C736

C739M
C739H

RCS

C704A
C704

100
100EL

100C.I.

200

100PVC

200VT
800

175

298

304
126

126PVC
179
267
159
258
158DB
260
114

69

84
139

127

227
227S
152

11
11X

11CI

110

110PC

11V
31

212

216

189
50

49PC
95
97
97
599
595
75
231
180

820

801
802

67
68
146
145
53

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 1/24/2007

TOLCO Cross Reference Chart


TOLCO

GRINNELL
& ANVIL

B-LINE

ERICO

PHD

SUPER STRUT

CARPENTER
& PATERSON

EMPIRE
INDUSTRIES

50
51
52
58
60
61
61T
62
64
65
66
68
69
69R
70
70R
70S
71
78
81
81PVC
82
82PVC
83
84
99
100
101
101L
102
102L
103
104
105
106
107
107F
108
109A
109F
110
111
113
114
115
116
117
118
119
120
120MJ
120RWAA
120RWAB
120W
122
123
124

202
206

227

133-134
95
92
93
93
89, 87

135
136R

135
128R
CT65

CT121

146
278
278X
248
248X
140

142

137
120

60

B3060

B3070

B3042

B3050
B351L

B3033
B3033
B3367

B655
B656

B3220
B3199
B3104CT
B3104CTC
B3373CT
B3373CTC
B3195CT
B3195CT

B3211
B3211X
B3210
B3210X
B3205
B3212
B3213

B3019
B2501
B3188
B3501

B3234

B3248

325

326

359

361
200
300
310

255C

25
25R
26S

402

511

51
50
40W

40

46

370A

150

10
10H
11

13
340
12

925

610, 620
250
350

360
359

100
105
104

940
442

552
554
982
980
10
20
55

50

15
60
40

70

885

90
95, 110
110
110H
130
135
134
960
136
80

540
AB201
542

C755T-C757T
C775L
C777
C778
M778
U568

H119
H119R

M742R
CTL710

CT720

C716

H104
E157

E156

E151

C745

H115
HL115
E145

E147

E148
C781
EF147

303

45
6

15
238
192

18

123
123R

123W
95
100CT
100PVC
126CT

94

93
341
22
306
133
31
28

177

283
222
165
103
103
706
176
102

44

59

202

159
158

218
21L
62
61

22R

51
51R

110CT
110PC
50CT
50CTI or 59PC

54

26W

26

57

55

77

81

137

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

56
52
52
72
52L
75
52F

83
84

61

www.tolco.com
Revision 1/24/2007

TOLCO Cross Reference Chart

62

TOLCO

GRINNELL
& ANVIL

B-LINE

ERICO

PHD

SUPER STRUT

CARPENTER
& PATERSON

EMPIRE
INDUSTRIES

125
126
130
200
200WON
202
203
207
209
210
219
220
244H
244HR
244C
244CR
260-1
261-1
262-2
263-2
264-3
265-4
301CT
302
304
305
306
307
309
309N
310
310N
312
313
315
316
316T
317
317A
318A
318
322
323
324
325
326
327
328
329
330
331
332
333
335
336
337

69

CT69

168
167

160
161
162
163
164
165
CT138R
138R
66
66
114
110R
181

282
285N
102
191

264

259
171

181
175
177
271
274
218, 229
290
230
299
157
217
14

DS16
B3228

B3170NF
105
B3170CT
B3170CTC

B3151

B3160
B3161
B3162
B3163
B3164
B3165
B3198HCT
B3198H
B3083WO
B3083WO
B3224
B3222
B3014
B3014N
B2500
N2500
B3096
B3092
B3093
B3088
B3088T
B3095
B3093
B3092
B3090
B3114R
B3121
B3110
B3120
B3122
B3117SL
B3118SL
B3054
B3200
B3202
B3201
B3203
B3045
B3040
B3082

43
42
356
130

101
102

125
126

127

630
631
632
633
634
635
456
455
320L
320W

47
282
282N
355
355N

724
722

720

721
605
621
610
615
620
617
619
360
35
30
31
26
369
363
321

48
45

E151D
E150S

CT727
CT727P

C790

C789
C789A
C789B
C789C
C789D
C789E
MT718
M718
C789W/O
C780W/HW

E120

452
AB102

C786

C786

C785

C729-2
C729-2
CR729A
RC729
C730C
C730D
M732
E120A
F112
F111
M129
C769

C747

166

800
1A
800CT
800PVC

265P

351
352
353
354
355
356
81CT

38
12

650-266-75

137

137

125

110
140
39
109

53
293

132
276

92
14

59

31
310
C10CTI

167

1900
1901
1902
1903
1904
1905
41HCT
41H

114
47

422

425 or 427

420
426
427
427
277
271
272
275
274
279S
280S
229
131
320
909
157
156
155

153

47W
47D
160
170
165

165

651
653
654
655
656
658
512H
508
900-1
900
44
32
950
950N

875
880
882

871
880
875
876
882
490

470
460
480
486
487
630
35
960
38
25

635

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 1/24/2007

TOLCO Cross Reference Chart


TOLCO

GRINNELL
& ANVIL

343
405
406
420
421
421C
422
425
426
427
428
429
430
431
432
500
505
506
568
580
581
582
598
650
800
825
825A
906
907
909
910
975
980
981
990
991
1000
1001
2002

55

256

255

280
436
437
438-1
438-2
438-3

178
247

B268
80-V
81H
82A-G
98A-G
296

112

B-LINE

ERICO

PHD

SUPER STRUT

CARPENTER
& PATERSON

EMPIRE
INDUSTRIES

B3080
B3256
B3257

B3281

B3891

B3891
B3892
B3893

371

650
651

640

640-1
640-2
640-3

625

335AB
335A

936

670-678

690

690-1
690-2
690-3

890

PG794

220

478

568

69

4000 Series

4100 Series

35

B3264

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

63

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - Grinnell to TOLCO

64

GRINNELL

TOLCO

GRINNELL

TOLCO

GRINNELL

TOLCO

GRINNELL

TOLCO

14
47
49
52
55
60
65
CT65
66
67
69
CT69
80-V
81H
82A-G
89, 87
92
93
95
98A-G
100
103
108
110R
112
114
120
CT121
CT138R
128R
133-134
135
136R
137
138R
140
142
146
157
160
161
162
163
164

336
33
34
35
343
118
1LD
81
305
3
200
202
580
581
582
69
65
66
64
598
8
7
303
307
910
306
111
82
301CT
78
62
70, 71
70R
110
302
103
105
100
333
260-1
261-11/2
262-2
263-21/2
264-3

178
181
191
192
194
195
199
202
206
212
212FP
216
217
227
230
247
248
248X
255
256
257
259
260
261
262
264
B268
271
274
278
278X
280
282
285N
290
295
296
299
300
436
437
438-1
438-2
438-3

500
324
313
312
30
30M
30H
50
51
4
4A
4H
335
60
331
505
102
102L
422
421
426
318
1
6
20
317/319
568
327
328
101
101L
426
309, 309N
310N
330
5
650
332
1A
427
428
429
430
431

1CBS
1F
1LDF
2
2F
2FWON
2WON
3F
4B
4C.I.
4F
6F
20S
21
21F
22
23
24
25
30L
31M
31O
32
40
41
42
52
58
61
69R
70S
83
84
99
104
106
107
107F
108
109
109F
113
114
115

120W
122
123
124
125
126
130
200WON
203
207
209
210
244H
244HR
244C
244CR
315
316
317
316T
318/319
323
337
405
406
420
421
425
432
506
800
825
825A
906
907
909
975
980
981
990
991
1000
1001
2002

165
167
168
171
175
177

265-4
220
219
322
325
326

590
594
595
599
600
218, 229

1C.I.
14X
14
9X
9
329

116
117
119
120
120MJ
120RWA

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - B-Line to TOLCO


B-LINE

TOLCO

B-LINE

TOLCO

B-LINE

TOLCO

B-LINE

TOLCO

DS16
B351L
B655
B656
B2500
N2500
B2501
B3014
B3014N
B3019
B3033
B3040
B3042
B3045
B3050
B3054
B3060
B3066
B3067
B3068
B3070
B3080
B3082
B3083WO
B3083
B3084
B3085
B3086
B3088
B3088T
B3090
B3092
B3093
B3095
B3096
B3100
B3100C
B3100F
B3102
B3104
B3104C
B3104CT
B3104CTC
B3104F
B3106
B3108
B3110
B3114
B3117SL
B3118SL

125
64
70
70R
310
310N
109F
309
309N
109
68
336
61
335
62
329
50
30M
30H
30
52
343
337
304
305
33
35
34
316
316T
318
318/319
317/319
317
312
1
1PVC
1F
1C.I.
1LD
1LDPVC
81
81PVC
1LDF
1V
1A
324
322
327
328

B3121
B3122
B3132
B3132W
B3134
B3134W
B3140
B3142
B3144
B3147
B3148
B3149
B3151
B3160
B3161
B3162
B3163
B3164
B3165
B3170
B3170CT
B3170CTC
B3170NFF
B3172
B3172F
B3173
B3180
B3188
B3190
B3191
B3195CT
B3198H
B3198HCT
B3199
B3200
B3201
B3202
B3203
B3205
B3210
B3210X
B3211
B3211X
B3212
B3213
B3220
B3224
B3228
B3234
B3248

323
326
9
9X
14
14X
4
4H
5
32
7
8
220
260-1
216-11/2
262-2
263-21/2
264-3
265-4
2
202
203
2F
2WON
2FWON
303
20
110
40
41
83
302
301CT
78
330
332
331
333
103
102
102L
101
101L
104
105
71
306
126
116
118

B3256
B3257
B3264
B3281
B3367
B3373
B3373C
B3373CT
B3373CTC
B3501
B3690
B3690F
B3891
B3892
B3893

405
406
500
421
69
6
6PVC
82
82PVC
111
3
3F
426
430
431
1CBS
4A
4B
4C.I.
4F
6F
20S
21
21F
22
23
24
25
30L
31M
31O
42
51
58
60
65
66
69R
70S
84
99
100
106
107
107F
108
113
114
115
117

120
120MJ
120RWA
120W
122
123
124
130
200
200WON
207
209
210
219
244H
244HR
244C
244CR
420
421C
422
425
427
428
432
505
506
568
580
581
582
598
650
800
825
825A
906
907
909
910
975
980
981
990
991
1000
1001
2002

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

65

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - MCO to TOLCO

66

MCO

TOLCO

MCO

TOLCO

MCO

TOLCO

MCO

TOLCO

8EG
10
10H
11
12
13
25
25R
25S
26
30
31
35
40
40W
42
43
46
47
50
51
100
100FL
102
105
125
126
127
130
150
200
255C
282
282N
300
310
319
320L
320W
321
325
326
335A
335AB
340
348
351
352
353
355
355N

21
113
114
115
119
117
70
70R
70S
333
331
332
330
102
101
126
125
106
307
100
99
2
2F
203
200WON
220
244H
244C
200
110
64
69
309
309N
64
66
42
304
305
337
50
52
975
910
118
30
30L
30M
30H
310
310N

356
359
360
361
363
367
370A
371
373
374
374A
400
400FL
402
40
410
410FL
41
418
418FL
450
451
452
455
456
457
458
470
510
511
516
517
605
610
615
617
619
620
621
625
630
631
632
633
634
635
640
640-1
640-2
640-3
651

130
61
329
62
336
335
109
343
33
34
35
1
1F
81
1C.I.
1LD
1LDF
1A
3
3F
4
4H
5
302
301CT
40
41
20
6
82
9X
9
322
324
325
327
328
326
323
500
260-1
261-11/2
262-2
263-21/2
264-3
265-4
426
429
430
431
421

651
700
705
712
720
721
722
724

420

520

107
108
109

421
7
8
32
317
318
315
313
1CBS
1PVC
1LDPVC
1V
2FWON
4A
4B
4C.I.
4F
6F
6PVC
14
14X
20S
21F
22
23
24
25
31M
31O
51
58
60
68
69R
71
78
81PVC
82PVC
83
84
101l
102L
103
104
107
107F
108
109F
111
116
120

101

120MJ
120RWAA
120RWAB
120W
122
123
124
202
207
209
210
219
244HR
244CR
303
306
312
316
316T
317/319
318/319
405
406
421C
422
425
427
428
432
505
506
568
580
581
582
598
650
800
825A
906
907
909
980
981
990
991
1000
1001
2001

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - PHD to TOLCO


PHD

TOLCO

PHD

TOLCO

PHD

TOLCO

PHD

TOLCO

10
15
20
25
32
35
38
40
44
45
47D
47W
48
50
55
60
70
80
90
95, 110
100
104
105
110
110H
130
134
135
136
151
151F
153
160
165
170
180
180F
250
350
359
360
420
430
440
440F
450
450F
450V
453
460
470

99
103
100
333
307
330
332
105
306
126
210
209
125
102
101
104
107
120
110
111
70
70S
70R
113
114
115
117
116
119
2
2F
203
219
244H/244C
220
2WON
2FWON
64
65
69
69
1C.I.
1A
1LD
1LDF
1
1F
1V
1PVC
325
324

480
486
487
490
500
508
512H
520
522
525
535
545
550
552
553
554
580
585
590
595
610, 620
630
635
651
653
654
655
656
658
670-678
690
810
820
825
830
840
850
855
860
871
875
876
880
882
885
890
900
900-1
903
904
910

326
327
328
322
303
302
301CT
4
4H
5
7
8
6
82
6PVC
82PVC
9
9X
14
14X
62
329
336
260-1
261-11/2
262-2
263-21/2
264-3
265-4
421
426
41
40
20
20S
32
30L
30M
30H
316T
317/319
318/319
317
318
109
975
305
304
35
34
42

925
930
936
940
950
950N
960
970
970F
980
982

52
118
343
78
309
309N
331
3
3F
84
83
1CBS
1LDPVC
4A
4B
4PVC
4C.I.
4F
4L
6F
21
21F
22
23
24
25
28
30
31M
31O
33
50
51
58
60
61
61T
66
69R
71
81PVC
101L
102L
106
107F
108
109F
120MJ
120RWAA
120RWAB
120W

690-1
690-2
690-3

122
124
130
200
200WON
202
207
244HB
244CR
310
310N
316
323
335
337
405
406
420
421C
422
425
427
428
429
430
431
432
500
505
506
568
580
581
582
598
650
800
825
825A
906
907
909
910
980
981
990
1000
1001
2002

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

67

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - Super Strut to TOLCO

68

SUPER
STRUT

TOLCO

SUPER
STRUT

TOLCO

SUPER
STRUT

TOLCO

AB102
F111
F112
H104
H115
H119
H119R
HL115
E120
E120A
M129
E145
E147
EF147
E148
E150S
E151
E151D
E156
E157
164
AB201
C475
452
540
542
U568
C704
C704A
C710
C710F
C710P
CI710
CL710
CTL710
CX710
C711
C711F
C716
M718
C720
C720L
C720P
CT720
C724
W724
C725
C725
C726
C727
C727

310N
332
331
100
110
70
70R
111
307
330
333
113
115
119
117
126
105
125
102
101
20
51
109
310
50
52
69
41
40
1
1F
1PVC
1C.I.
1LD
81
1A
3
3F
83
302
6
7
6PVC
82
9
9X
2FWON
4
5
2
2WON

C727F
CT727
CT727P
C729-2
C729-2
CF729A
RC729
C730C
C730D
M732
C736
C739H
C739M
M742R
C747
C755T-C757T
C777
C769
C775L
C778
M778
C780W/HW
C780W/O
C781
C785
C786
C789
C789A
C789B
C789C
C789D
C789E
C790
PG794
RCS

2F
202
203
324
323
325
326
327
328
329
30
30H
30M
78
337
62
65
335
64
66
68
305
304
118
318
317/319
260-1
260-11/2
262-2
263-21/2
264-3
265-4
220
421
32
1CBS
1LDF
1LDPVC
1V
4B
4C.I.
4F
4H
4L
4PVC
6F
14
20S
21
21F
22

23
24
25
28
30L
31M
31O
33
34
35
42
58
60
61
61T
69R
70S
71
81PVC
82PVC
84
89
101L
102L
103
104
106
107
107F
108
109F
114
116
120
120MJ
120RWA
120W
122
123
124
130
200
200WON
207
209
210
219
244HR
244C
244CR
303

SUPER
STRUT

TOLCO

306
309
309N
312
313
316
316T
317
318/319
322
336
343
405
406
420
421C
422
425
426
427
428
429
430
431
432
500
505
506
568
580
581
582
598
650
800
825
825A
906
907
909
910
975
980
981
990
991
1000
1001
2002

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - Carpenter & Paterson to


TOLCO
CARPENTER &
CARPENTER &
CARPENTER &
CARPENTER &
TOLCO
TOLCO
TOLCO
PATERSON
PATERSON
PATERSON
PATERSON
6
12
14
15
18
28
31
33
38
39
44
45
53
59
69
84
85
92
93
94
100
102
103
109
110
114
123
125
126
127
132
133
137
137
139
140
152
158
165
166
175
176
177
179
192
200
220
222
227
258
260

61
307
336
62
69
105
104
102
306
325
120
60
328
123
30
30M
78
335
101
99
1
118
115
326
323
20
70
318
6
32
331
103
312
315
30H
324
42
9
113
125
4
117
107
7
65
1LD
343
111
40
9X
14X

267
276
283
293
298
303
304
306
341
351
352
353
354
355
356
399
478
706
800
800
100C.I.
100CT
100EL
100PVC
100PVC
123R
123W
126CT
126PVC
158DB
1A
200VT
227S
265P
650-266-75
800CT
800PVC
81CT

8
332
110
329
4H
50
5
102L
101L
260-1
260-11/2
262-2
263-21/2
264-3
265-4
568
500
116
2
200
1C.I.
81
1A
1PVC
81PVC
70R
71
82
6PVC
14
200WON
1V
41
220
309N
202
203
301CT
1CBS
1F
1LDF
1LDPVC
2F
2FWON
3
3F
4A
4B
4C.I.
4F
4L

4PVC
6F
20S
21
21F
22
23
24
25
27
27A
28
30L
31-M
31-O
33
34
35
51
52
58
61T
66
68
69R
70S
82PVC
83
84
100
106
107F
108
109
114
119
120MJ
120RWAA
120W
122
124
126
130
207
209
210
219
244H
244HR
244C
244CR

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

TOLCO
302
303
304
305
309
310
310N
313
316
316T
317
317/319
318/319
322
327
330
333
337
405
406
421
421C
422
425
426
427
428
429
430
431
432
505
506
580
581
582
598
650
800
825A
906
907
910
975
980
981
990
991
1000
1001
2002

69

www.tolco.com
Revision 5/24/2001

Cross Reference Chart - Empire Industries to TOLCO

70

EMPIRE
INDUSTRIES

TOLCO

EMPIRE
INDUSTRIES

TOLCO

EMPIRE
INDUSTRIES

TOLCO

11
26
31
31
35
47
50
51
52
53
54
55
56
57
59
61
62
67
68
69
72
75
75
77
80
81
83
84
95
97
110
114
137
145
146
150
155
156
157
158
159
167
180
189
202
212
216
218
229
231
255
256

1
102
2
200
506
307
6
70
115
42
99
105
113
103
125
66
65
34
35
343
116
14X
118
107
209
108
123
124
7
8
1LD
306
110
41
40
130
336
335
333
61
60
220
20S
5
50
4
4H
62
329
20
421C
421

271
272
273
275
277
310
320
420
422
426
427
427
595
599
600
801
802
320
909
1900
1901
1902
1903
1904
1905
110CT
110PC
110PC
11CI
11V
11X
131
21L
22R
26W
279S
280S
310CTI
4000 Series
4100 Series
41H
41HCT
425 or 427
49PC
50CT
50CTI or 49PC
51R
52F
52L
81N

323
324
326
325
322
200WON
331
317
312
317/319
318/319
318
14
9X
9
30M
30H
30
332
260-1
260-11/2
262-2
263-21/2
264-3
265-4
81
1PVC
81PVC
1C.I.
1V
1A
330
64
69
101
327
328
202
426
429
302
301CT
313
6PVD
82
82PVC
70R
119
117
309N
1CBS
1F

1LDF
1LDPVC
2F
2FWON
3
3F
4A
4B
4C.I.
4F
4L
4PVC
6F
21
21F
22
23
24
25
27
27A
28
30L
31-M
31-O
33
51
52
58
61T
68
69R
70S
71
78
83
84
100
101L
102L
104
106
107F
109
109F
111
114
120
120MJ
120RWAA
120W
122

EMPIRE
INDUSTRIES

TOLCO

126
203
307
210
219
244H
244HR
244C
244CR
303
304
305
309
310
310N
315
316
316T
337
405
406
422
425
427
428
430
431
432
500
505
568
580
581
582
598
650
800
825A
906
907
909
910
975
980
981
990
991
1000
1001
2002

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

www.tolco.com
Revision 5/24/2001

TOLCO to MSS and Federal Specification Cross Reference


TOLCO
1
1A
1LD
2
2NFPA
2WON
3
4
4 CI
4H
5
6
20
20S
30L
30M
30H
62
64
65
66
68
81
82
110
200
200WON
202
203
220
260-1
261-112

MSS-SP-69

Federal Spec.
Ww-H-171E

Type 1
Type 1

Type 10
Type 10
Type 7
Type 5
Type 4
Type 4
Type 4
Type 3
Type 8
Type 26
Type 26
Type 31
Type 32
Type 33
Type 21
Type 23
Type 19
Type 19
Type 19

Type 8
Type 24
Type 10
Type 7
Type 10
Type 10
Type 40
Type 39
Type 39

Type 1
Type 1
Type 12
Type 10
Type 10
Type 7

Type 4
Type 4
Type 4
Type 3
Type 8
Type 26
Type 26
Type 32
Type 33
Type34
Type 21
Type 23
Type 23
Type 23
Type 23
Type 12
Type 8
Type 24
Type 10
Type 7
Type 10
Type 10
Type 41
Type 40A & 40B
Type 40A & 40B

TOLCO

MSS-SP-69

Federal Spec.
Ww-H-171E

262-2
263-212
264-3
265-4
301CT
302
303
304
305
306
307
309
310
317
318
317A
322
324
327
328
329
330
331
332
335
336
343
499
500
568
580
582
598
650

Type 39
Type 39
Type 39
Type 39
Type 12
Type 12
Type 11
Type 22
Type 22
Type 15
Type 16
Type 18
Type 18
Type 36
Type 37
Type 38
Type 41
Type 43
Type 44
Type 46
Type 30
Type 17
Type 13
Type 14
Type 25
Type 27
Type 57
Type 58
Type 49
Type 51
Type 54 & 55
Type 51
Type 51
Type 50

Type 40A & 40B


Type 40A & 40B
Type 40A & 40B
Type 40A & 40B
Type 25
Type 25
Type 11
Type 22
Type 22
Type 15
Type 16
Type 18
Type 19
Type 37
Type 38
Type 39
Type 42
Type 44
Type 45
Type 47
Type 30
Type 17
Type 13
Type 14
Type 53
Type 54

Type 50
Type 51
Type 52
Type 51
Type 51

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

71

www.tolco.com
Revision 5/24/2001

Beam Dimensions
American Standard
Channels C Shapes

Designation Flange
Depth & Wt. Width
"x" Lbs.
"Y"
C3
C3
C3
C4
C4
C5
C5
C6
C6
C6
C7
C7
C7
C8
C8
C8
C9
C9
C9
C10
C10
C10
C10
C12
C12
C12
C15
C15
C15
C18
C18
C18
C18

72

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

4.1
5.0
6.0
5.4
7.25
6.7
9.0
8.2
10.5
13.0
9.8
12.25
14.75
11.5
13.75
18.75
13.4
15.0
20.0
15.3
20.0
25.0
30.0
20.7
25.0
30.0
33.9
40.0
50.0
42.7
45.8
51.9
58.0

138
112
158
158
134
134
178
178
2
218
218
214
214
214
238
212
212
212
258
258
234
278
3
3
3
318
338
312
334
4
4
418
414

Ave.
Thickness
"Z"
.250
.313
.313
.375

.375

.375

.438

.438

.500

.625

.625

American Standard
I Beams S Shapes

Designation Flange
Depth & Wt. Width
"x" Lbs.
"Y"
S3
S3
S4
S4
S5
S5
S6
S6
S7
S7
S8
S8
S10
S10
S12
S12
S12
S12
S15
S15
S18
S18
S20
S20
S20.3
S20.3
S24
S24
S24

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

5.7
238
7.5
212
7.7
258
9.5
234
10.0
3
14.75 314
12.5
338
17.25 358
15.3
358
20.0
378
18.4
4
23.0
418
25.4
458
35.0
5
31.8
5
35.0
518
40.8
514
50.0
512
42.9
512
50.0
558
54.7
6
70.0
614
66.0
614
75.0
638
86.0
7
96.0
714
80.0
7
90.0
718
100.0 714

Ave.
Thickness
"Z"
.250
.313
.313
.375
.375
.438
.500
.563
.688
.625
.688
.813
.938
.875

American Standard Wide Flange W Shapes

Designation Flange
Depth & Wt. Width
"x" Lbs.
"Y"
W4
W5
W6
W8
W8
W8
W8
W8
W8
W8
W8
W8
W8
W10
W10
W10
W10
W10
W10
W10
W10
W10
W10
W10
W12
W12
W12
W12
W12
W12
W12
W12
W12
W12
W12
W12
W12
W12
W14
W14
W14
W14
W14
W14
W14
W14
W14
W14
W14

x 13
x 19
x 25
x 18
x 21
x 24
x 28
x 31
x 35
x 40
x 48
x 58
x 67
x 22
x 26
x 33
x 39
x 45
x 49
x 54
x 60
x 68
x 77
x 88
x 26
x 30
x 35
x 40
x 45
x 50
x 53
x 58
x 65
x 72
x79
x 87
x 96
x 106
x 30
x 34
x 38
x 43
x 48
x 53
x 61
x 68
x 74
x 82
x 90

4
5
518
514
514
612
612
8
8
818
818
814
814
534
534
8
8
8
10
10
1018
1018
1014
1014
612
612
612
8
8
818
10
10
12
12
1218
1218
1218
1214
634
634
634
8
8
8
10
10
1018
1018
1412

Ave.
Thickness
"Z"
.375
.430
.455
.330
.400
.400
.465
.435
.495
.560
.685
.810
.935
.360
.440
.435
.530
.620
.560
.615
.680
.770
.870
.990
.380
.440
.520
.515
.575
.640
.575
.640
.605
.670
.735
.810
.900
.990
.385
.455
.515
.530
.595
.660
.645
.720
.785
.855
.710

Designation Flange
Depth & Wt. Width
"x" Lbs.
"Y"
W14
W14
W14
W14
W16
W16
W16
W16
W16
W16
W16
W16
W16
W18
W18
W18
W18
W18
W18
W18
W18
W18
W21
W21
W21
W21
W21
W21
W21
W21
W24
W24
W24
W24
W24
W24
W27
W27
W27
W27
W30
W30
W30
W30
W33
W33
W33
W36
W36
W36

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

99
109
120
132
36
40
45
50
57
67
77
89
100
50
55
60
65
71
76
86
97
106
62
68
73
83
93
101
111
122
76
84
94
104
117
131
94
102
114
146
108
116
134
132
118
130
141
135
150
160

1458
1458
1458
1434
7
7
7
718
718
1014
1014
1038
1038
712
712
712
758
758
11
1118
1118
1114
814
814
814
838
838
1214
1238
1238
9
9
918
1234
1234
1278
10
10
1018
14
1012
1012
1012
1012
1112
1112
1112
12
12
12

Ave.
Thickness
"Z"
.780
.860
.940
1.030
.630
.505
.565
.630
.715
.665
.760
.875
.985
.570
.630
.695
.750
.810
.680
.770
.870
.940
.615
.685
.740
.835
.930
.800
.875
.960
.680
.770
.875
.750
.850
.960
.745
.830
.930
.975
.760
.850
.930
1.000
.740
.855
.960
.790
.940
1.020

www.tolco.com
Revision 5/24/2001

Decimals of a Foot
Inch

0"

0
1/16
1/8
3/16
1/4
5/16
3/8
7/16
1/2
9/16
5/8
11/16
3/4
13/16
7/8
15/16

0
.0052
.0104
.0156
.0208
.0260
.0313
.0365
.0417
.0469
.0521
.0573
.0625
.0677
.0729
.0781

1"

2"

3"

4"

5"

6"

7"

8"

9"

10"

11"

.0833
.0085
.0938
.0990
.1042
.1094
.1146
.1198
.1250
.1302
.1354
.1406
.1458
.1510
.1563
.1615

.1667
.1719
.1771
.1823
.1875
.1927
.1979
.2031
.2083
.2135
.2188
.2240
.2292
.2344
.2396
.2448

.2500
.2552
.2604
.2656
.2708
.2760
.2812
.2891
.2917
.2969
.3021
.3073
.3125
.3177
.3229
.3281

.3330
.3385
.3438
.3490
.3542
.3594
.3646
.3724
.3750
.3802
.3854
.3906
.3958
.4010
.4063
.4118

.4167
.4219
.4271
.4323
.4375
.4427
.4479
.4557
.4583
.4635
.4688
.4740
.4792
.4844
.4896
.4948

.5000
.5052
.5104
.5156
.5208
.5260
.5313
.5391
.5417
.5469
.5521
.5573
.5625
.5677
.5729
.5781

.5833
.5885
.5938
.5990
.6042
.6094
.6146
.6224
.6250
.6302
.6354
.6406
.6458
.6510
.6563
.6615

.6667
.6719
.6771
.6823
.6875
.6927
.6979
.7057
.7083
.7135
.7188
.7240
.7292
.7344
.7396
.7448

.7500
.7552
.7604
.7656
.7708
.7760
.7813
.7891
.7917
.7969
.8021
.8073
.8125
.8177
.8229
.8221

.8333
.8385
.8438
.8490
.8542
.8594
.8646
.8724
.8750
.8802
.8854
.8906
.8958
.9010
.9063
.9115

.9167
.9219
.9271
.9323
.9375
.9427
.9479
.9557
.9583
.9635
.9688
.9740
.9792
.9844
.9896
.9948

Decimals of an Inch
Fraction

Decimal
1/32

1/16
3/32
1/8
5/32
3/16
7/32
1/4
9/32
5/16
11/32
3/8
13/32
7/16
15/32
1/2

.0312
.0625
.0937
.1250
.1562
.1875
.2187
.2500
.2812
.3125
.3437
.3750
.4062
.4375
.4687
.500

Fraction

Decimal
17/32

9/16
19/32
5/8
21/32
11/16
23/32
3/4
25/32
13/16
27/32
7/8
29/32
15/16
31/32

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

.5312
.5625
.5937
.6250
.6562
.6875
.7187
.7500
.7812
.8125
.8437
.8750
.9062
.9375
.9687

73

www.tolco.com
Revision 5/24/2001

Steel Pipe Data


Schedule 40 & 80
Pipe
Size

Sched.
No.

3/8

40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80

1/2
3/4
1
114
112
2
212
3
312
4

Wall
Wt. Per Water Weight
Thickness Foot
per Ft./Lbs

O.D.
.675
.840
1.050
1.315
1.660
1.900
2.375
2.875
3.500
4.000
4.500

.091
.126
.109
.147
.113
.154
.133
.179
.104
.191
.145
.200
.154
.218
.203
.276
.216
.300
.226
.318
.237
.337

.567
.738
.850
1.087
1.130
1.473
1.678
2.171
2.272
2.996
2.717
3.631
3.652
5.022
5.790
7.660
7.570
10.250
9.110
12.510
10.790
14.980

.083
.061
.132
.101
.230
.186
.374
.311
.647
.555
.882
.765
1.452
1.279
2.072
1.834
3.200
2.860
4.280
3.850
5.510
4.980

Pipe
Size

Sched.
No.

40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80
40
80
20
API

6
8
10
12
14
16
18
20
24
30
36

O.D.
5.563
6.625
8.625
10.750
12.750
14.000
16.000
18.000
20.000
24.000
30.000
36.000

Wall
Wt. Per Water Weight
Thickness Foot
per Ft. Lbs.
.258
.375
.280
.432
.322
.500
.365
.593
.406
.687
.437
.750
.500
.843
.563
.937
.593
1.031
.687
1.218
.500
.500

14.620
20.780
18.970
28.570
28.550
43.390
40.480
64.400
53.600
88.60
63.00
107.000
83.000
137.000
105.000
171.000
123.000
209.000
171.000
297.000
158.000
190.000

8.660
7.870
12.510
11.290
21.600
19.800
34.100
31.100
48.500
44.000
58.500
51.200
76.500
69.700
97.200
88.500
120.400
109.400
174.200
158.200
286.000
417.000

Copper Tube Data


Type L

74

Type K

Nom.
Tube
Size

O.D.
Tubing

O.D.

1/4
3/8
1/2
5/8
3/4
1
114
112
2
212
3
312
4
5
6

3/8
1/3
5/8
3/4
7/8
118
138
158
218
258
318
358
418
518
618

.375
.500
.625
.750
.875
1.125
1.375
1.625
2.125
2.625
3.125
3.625
4.125
5.125
6.125

Wall
Wt. Per Water Weight
Thickness Foot
per Ft./Lbs
.030
.035
.040
.042
.045
.050
.055
.060
.070
.080
.090
.100
.110
.125
.140

.126
.198
.285
.362
.455
.655
.884
1.140
1.75
2.480
3.330
4.290
5.380
7.610
10.200

.034
.062
.100
.151
.209
.357
.546
.767
1.341
2.064
2.949
3.989
5.188
8.081
11.616

Nom.
Tube
Size

O.D.
Tubing

O.D.

1/4
3/8
1/2
5/8
3/4
1
114
112
2
212
3
312
4
5
6

3/8
1/2
5/8
3/4
7/8
118
138
158
218
258
318
358
418
518
618

.375
.500
.625
.750
.875
1.125
1.375
1.625
2.125
2.625
3.125
3.625
4.125
5.125
6.125

Wall
Wt. Per Water Weight
Thickness Foot
per Ft. Lbs.
.035
.049
.049
.049
.065
.065
.065
.072
.083
.095
.109
.120
.134
.160
.192

OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 PH: 951.737.5599 FAX: 951.737.0330
CUSTOMER SERVICE 800.786.5266
www.tolco.com

.145
.269
.344
.418
.641
.839
1.040
1.360
2.050
2.920
4.000
5.120
6.510
9.670
13.870

.032
.055
.094
.144
.188
.337
.527
.743
1.310
2.000
2.960
3.900
5.060
8.000
11.200

www.tolco.com
Revision 5/24/2001

Cast Iron Pipe Data


American Water Works Assn. (AWWA)
Mechanical Joint Pipe Class 150. Approximately same weight for Bell & Spigot. Flanged cast iron pipe add weight of flanges

Pipe Size
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

O.D.
C.I. Pipe
3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30
44.50
50.80

Wall
Thickness
.32
.35
.38
.41
.44
.48
.51
.54
.58
.62
.73
.85
.94
1.05
1.14

Wt. Per
Foot
12.2
16.4
25.7
36.7
48.7
62.9
78.8
95.0
114.7
135.9
190.4
277.3
368.9
479.1
595.2

Standard No Hub Soil Pipe


Pipe Size
2
3
4
5
6
8
10

O.D.

I.D.

2.25
3.25
4.25
5.25
6.25
8.38
10.50

1.89
2.89
3.89
4.87
5.85
7.94
9.98

Wt. of Water
per Ft./Lbs.
3.73
5.72
12.80
23.10
35.50
51.00
69.30
90.30
114.00
141.50
201.00
312.00
449.00
612.00
803.00

Extra Heavy Soil Pipe


Pipe Size
2
3
4
5
6
8
10

O.D.

I.D.

2.38
3.50
4.50
5.50
6.50
8.62
10.75

2.00
3.00
4.00
5.00
6.00
8.00
10.00

Load Carrying Capacities of Threaded Steel Rod


Rod
Diameter In.
3/8
1/2
5/8
3/4
7/8
1
11/8
11/4
11/2
13/4
2
21/2
21/2
*

Root Area
Thread Sq. In.
.068
.126
.202
.302
.419
.552
.693
.889
1.293
1.744
2.300
3.023
3.719

Max. Safe Load


in Lbs. @650F*
610
1130
1810
2710
3770
4960
6230
8000
11630
15700
20700
27200
33500

Max. Rec. Load


in Lbs. @ 750F*
540
1010
1610
2420
3360
4420
5560
7140
10370
14000
18460
24260
29800

Weight per
Ft./Lbs.
.376
.668
1.040
1.500
2.400
2.670
3.380
4.170
6.010
8.180
10.680
13.520
16.960

Maximum recommended load based on minimum safety factor of 5.

Main Office/Manufacturing Facility 1375 Sampson Ave. Corona, CA 92870 Ph: 951.737.5599 Fax: 951.737.0330
Customer Service 800.786.5266
www.tolco.com

Fittings
Wrot and cast copper pressure fittings Wrot and cast copper drainage fittings
Cast copper alloy flared fittings Cast copper alloy flanges ABS and PVC DWV
fittings Schedule 40 PVC pressure fittings CPVC CTS fittings CPVC CTS-tometal transition fittings Schedule 80 PVC and CPVC systems CPVC metric piping
systems CPVC BlazeMaster fire protection fittings
BlazeMaster is a registered trademark of The Lubrizol Corporation.

Valves & Actuation


Pressure-rated bronze, iron and alloy-iron gate, globe and check valves Pressurerated bronze ball valves Boiler specialty valves Commercial and industrial butterfly
valves Circuit balancing valves Carbon and stainless steel ball valves ANSI flanged
steel ball valves Pneumatic and electric actuators and controls Grooved ball and
butterfly valves High performance butterfly valves UL/FM fire protection valves
Low-pressure gate, globe, check and ball valves Bronze specialty valves Frostproof
sillcocks Quarter-turn supply stops MSS specification valves PVC ball valves
CPVC CTS ball valves Just Right recirculating valves
Chemtrol
Thermoplastic pipe, valves and fittings in PVC, Corzan CPVC, polypropylene and
PVDF Kynar Pneumatic and electric actuation systems
Corzan is a registered trademark of The Lubrizol Corporation.
Kynar is a registered trademark of Arkema Inc.

Supporting
the Flow.

eNIBCO
A suite of services designed to make customers more efficient More cost-effective
More informed EDIElectronic Data Interchange VMIVendor Managed Inventory
NIBCO.com NIBCOpartner.com eNIBCO will continuously develop new products to
deliver the competitive advantage

Every solution
begins with
TOLCO.

TOLCO
Office / Manufacturing
1375 Sampson Avenue
Corona, California 92879
USA
Phone:
Fax:

951.737.5599
951.737.0330

We're committed to

supporting all of your flow

Customer Service:
Phone: 800.786. 5266

control needs. We can provide


Pipe Hangers Pipe Supports
TOL-Strut Channel Seismic Bracing

creative solutions for your


most challenging bracing and
support applications. Solutions
that make your installations
easier, safer and more
cost-effective.
For solutions that will support
your flow-control applications,
call on us. We're TOLCO, a
product line committed to
quality, service and innovation
Supporting the Flow.

C-TOLFP-0708

www.tolco.com
NIBCO INC.
World Headquarters
1516 Middlebury Street
Elkhart, IN 46515-1167
USA
Customer Service:
Phone: 800.234.0227
Fax: 800.234.0557
Technical Service:
Phone: 888.446.4226
www.nibco.com

Das könnte Ihnen auch gefallen