Beruflich Dokumente
Kultur Dokumente
MECHANICALEQUIPMENTCATEGORYAHUFAMILIES
ThisdocumentincludesAutodeskspecificationsforthecreationofRevitAirHandlingUnitfamilieswithintheRevit
MechanicalEquipmentcategory.FollowingthecriteriasuggestedbyboththisguideandtheRevitModelContent
StyleGuidewillenablemanufacturersandothercontentcreatorstocreateAirHandlingfamiliesthatadhereto
AutodeskandAutodeskSeekstandardsforRevitMechanicalEquipmentfamilies.
Whilethisdocumentcontainsspecificairhandlingunitfamilycreationguidelines,itisnotintendedtoprovide
specificationsforeverykindofairhandlingunit.Asampleairhandlingunitfamilyisprovidedasanexampleto
conveythestandardsoutlinedwithinthisdocument,butmanyotherairhandlingunittypesmaybecreatedusing
theseresourcesasareference.
RMCSG2.1page1
AIRHANDLINGUNITS
Category:MechanicalEquipment
Behavior:Nonhosted
FamilyTemplate(s):
ImperialTemplates
MechanicalEquipment.rft
Metric(generic)Templates
MetricMechanicalEquipment.rft
NOTE:DonotusethewallorceilinghostedfamilytemplatesastheywillnotworkinaMEPfilewithalinked
architecturalmodel.
NAMINGCONVENTIONS
Usethefollowingguidelineswhennaminganewairhandlingunitfamily:
Format:
<FunctionalType><Subtype><Manufacturer><Descriptor1><Descriptor2>
Note:RefertotheRevitMasterPartTypeList(includedinthedownloadpackage)forinformationonapproved
FunctionTypesandSubtypes.
Guidelines:
Createuniquenamesforeachairhandlingunitfamily.
Usenaturallanguagetonamethefamily.
Thefamilynameshoulddescribehowthefamilyisidentifiedintherealworld(forexample,incatalogsor
bymanufacturer).
Ifpossible,donotincludethefamilycategoryinthefamilyname.
UseaDescriptorparametertoincludeamodelnumber,coolingorflowrate,ifappropriate.
Capitalizetheleadinglettersineachportionofthefamilyname.
Keepfilenamesasshortaspossible.
FamilynamesmustdisplayindialogsandinTypeSelector.
Do not use spaces between words in file names. To separate words within a syntax element (e.g.,
ManufacturerorDescriptor),usetheunderscorecharacter(_).
Ifatypecatalogistobeusedwithafamily,namethetypecatalog(.txtfile)withthesamenameasthe
family.
RMCSG2.1page2
Examples:
Air_Handling_UnitPackagedAcme_MechanicalSeries_I(3050Ton)
Air_Handling_UnitModularAcme_MechanicalSeries_3(7501200CFM)
RMCSG2.1page3
SUBCATEGORIES
Themechanicalequipmentfamilytemplate(mechanicalequipment.rft)thatisprovidedwiththeRevitsoftware
createssubcategoriesthatyoucanusetocontrolthedisplayofairhandlingunitgeometry(seeTable1below).
Youmaynotneedtousethedefaultsubcategorythatisprovidedbythemechanicalequipmentfamilytemplate.
Youmayalsoneedtoaddsubcategories.Table2belowcontainsalistofAutodeskapprovedsubcategoriesthat
youcanaddtomechanicalequipmentfamilies.IfyouneedtoaddsubcategoriesthatarenotlistedinTable2,use
thesubcategorynamingconventionsandapprovalproceduredescribedintheRevitModelContentStyleGuide.
Table1DefaultsubcategoriesandsettingsprovidedbytheMechanicalEquipment.rfttemplate:
Category/Subcategory
MechanicalEquipment
HiddenLines
LineWeight
Projection
Cut
1
LineColor
Black
Black
LinePattern
Solid
Dash
Material
LinePattern
Solid
Material
Table2Createtheseadditionalsubcategoriesasneeded:
Category/Subcategory
AirHandlingUnit
RMCSG2.1page4
LineWeight
Projection
Cut
1
LineColor
Black
CONNECTORSETTINGS
ThissectionincludestheparametersfortypicalconnectorsusedinAirHandlingUnits.Itisimportanttoverifythe
connectorsettingsbeforetestingthefamily.
TypicalAHUConnectors
ID
1
2
3
4
5
6
7
8
ConnectorDescription
EquipmentPower
ChilledWaterConnectionInlet
ChilledWaterConnectionOutlet
HeatingWaterConnectionInlet
HeatingWaterConnectionOutlet
SupplyAir
ReturnAir
CondensateDrain
Discipline
Electrical
Piping
Piping
Piping
Piping
HVAC
HVAC
Piping
Placement
Face
Face
Face
Face
Face
Face
Face
Face
Shape/Type
Power
Round
Round
Round
Round
Rectangular
Rectangular
Round
HVACConnectorParameters:
ID
FlowDirection
SystemType
FlowConfiguration
Flow
LossMethod
PressureDrop
PipeConnectorParameters:
ID
Connector
Description
2
ChilledWater
ConnectionInlet
FlowDirection
SystemType
AllowSlope
Adjustments
Flow
Configuration
Flow
6
Out
Supply Air
Calculated
ActualSupplyAirflow
NotDefined
N/A
7
In
Return Air
Calculated
ActualReturn Airflow
NotDefined
N/A
4
Heating Water
ConnectionInlet
In
HydronicSupply
No
3
ChilledWater
Connection
Outlet
Out
HydronicReturn
No
8
Condensate
Drain
In
HydronicSupply
No
5
HeatingWater
Connection
Outlet
Out
HydronicReturn
No
Preset
Preset
Preset
Preset
Preset
Family Actual
ChilledWater
Flow
Family Actual
ChilledWater
Flow
Family Actual
HeatingWater
Flow
Family Actual
HeatingWater
Flow
Family Actual
Condensate
DrainFlow
Out
Sanitary
Yes
RMCSG2.1page5
ID
LossMethod
PressureDrop
2
NotDefined
0
Radius
Family Chilled
Water
ConnectionInlet
Radius
ElectricalConnectorParameters:
ID
PowerFactor
ApparentLoad
Voltage
SystemType
LoadClassification
PowerFactorState
BalancedLoad
NumberofPoles
RMCSG2.1page6
3
SpecificLoss
Family Cooling
CoilWater
PressureDrop
Family Chilled
Water
Connection
OutletRadius
4
NotDefined
0
Family Heating
Water
ConnectionInlet
Radius
1
1.0
Family ApparentLoad
Family Voltage
Power Balanced
HVAC
Lagging
Yes
Family NumberofPoles
5
SpecificLoss
Family Heating
CoilWater
PressureDrop
Family Heating
Water
Connection
OutletRadius
8
NotDefined
N/A
Family
Condensate
Drain
Connection
Radius
REFERENCEPLANES
Usereferenceplanesinairhandlingunitfamiliestocontroldimensioningandsnapping.Anumberofpredefined
andnamedreferenceplanesareprovidedbythetemplateusedwhencreatinganairhandlingunitfamily.(See
Table1below)
Table1ReferencePlanesprovidedbytheMechanicalEquipment.rfttemplate:
Name
Center(Left/Right)
Center(Front/Back)
IsReference(strength)
Center(Left/Right)(Strong)
Center(Front/Back)(Strong)
NotaReference
DefinesOrigin?
Yes
Yes
Yes
Table2ReferencePlanestobeaddedtotheMechanicalEquipmentfamilyfile:
Name
RenametoBottom
Top
Front
Back
Left
Right
IsReference(strength)
Bottom
Top
Front
Back
Left
Right
DefinesOrigin?
Yes
No
No
No
No
No
Whenyouneedtoaddreferenceplanestoanairhandlingunitfamily:
Anyreferenceplanesthatyoudonotneedtodimensionorsnapto,shouldbesettoanIsReferencevalue
ofNotaReference.
Keepreferenceplanenamingconsistentwiththoseprovidedbythetemplate.
RMCSG2.1page7
PARAMETERUSAGE
AlistthatcontainsallAutodeskapprovedparameters,RevitMasterParameterList.xls,isprovidedinthedownload
package.TheMechanicalEquipmentsectionofthislistcontainsalloftheapprovedparametersforAirHandling
Unitfamilies.Inthefollowingimage,asmallsampleofthesharedparametersforMechanicalEquipmentisshown.
IMPORTANT:RefertotheRevitMasterParameterListforcompleteinformation.
Inaddition,amastersharedparameter.txtfilewhichincludingstandardAutodesksharedparametersisalso
includedinthedownloadpackage.
MakesurethatanyparametersaddedtoanairhandlingunitfamilyareincludedintheRevitMasterParameter
List.Ifnewunlistedparametersareneeded,usetheparameternamingconventionsandapprovalprocedure
describedintheRevitModelContentStyleGuide.
Thenextsectionsdescribesomeoftheparametersthatshouldbeconsidered,orpossiblyincludedwhencreating
anairhandlingunitfamilyfordistribution.
RMCSG2.1page8
DIMENSIONPARAMETERS
Themaindimensionparametersforairhandlingunitfamiliesare:
Width
SupplyAirConnectionWidth
SupplyAirConnectionHeight
ReturnAirConnectionWidth
ReturnAirConnectionHeight
Length
Height
TheHeightandWidthparametersdeterminethebasicdimensionsoftheairhandlingunitfamily.TheSupplyand
ReturnAirConnectionWidthandHeightparameterscontrolthedimensionsfortheairconnectionsandgeometry.
Whenthefamilyisloadedintoaprojectandanairhandlingunitiscreated,height,lengthandwidthdimensions
willdisplaytheHeight,LengthandWidthparametervalues.
CSIOMNICLASS1.0,MASTERFORMAT2004,ANDUNIFORMATIIPARAMETERS
OnAutodeskSeek,airhandlingunitfamiliescanbelocatedbytheappropriateCSIOmniclass1.0,MasterFormat
2004,andUniFormatIIcodes.WhensharingcontentwithAutodeskSeek,indicatethecodewithinthe
classificationthatshouldbeassignedtothecontent.
RefertotheRevitModelContentStyleGuideforinformationonincludingCSIClassificationCodeswithRevit
families.
AUTODESKSEEKSPECIFICSHAREDPARAMETERS
Inadditiontothesystemparameters,thereareanumberofsharedparametersthatcanbeaddedtoairhandling
unitfamilies.Manyoftheseparameterscanbeusedtofilterresultswhensearchingforairhandlingunitfamilies
onAutodeskSeek.Itisrecommendedtoaddtheseparameterstomanufacturedairhandlingunitsintendedfor
distributiononAutodeskSeek.
RefertotheRevitMasterSharedParameterFile.txt(includedinthedownloadpackage)foralistoftheAutodesk
approvedsharedparameters.
COSTPARAMETER
When creating a manufactured air handling unit for distribution on Autodesk Seek, it is recommended to not
specifyactualdatafortheCostparameterasthevaluewillchangewithtimeand/orconfigurationofthespecified
product.(TolocatetheCostparameter,opentheFamilyTypesdialogforthefamily,andscrolltotheIdentityData
section.)
RMCSG2.1page9
TYPES
NAMINGCONVENTIONS
All air handling unit families must include one predefined type. Predefined types should be generated for
familiesthatareavailableinstandardsizes.Unlesstheyrepresentnominalsizes,typenamesshouldinclude
unitsorcapacityandincludeaunitindicator.
Format:
Formanufacturerspecificairhandlingunitcontent:
Useadescriptive,catalogcodefortheairhandlingunitnameandsize:
<size>Ton<value>BTU<descriptor1><descriptor2>
Ifthefamilynameincludesanyspecificproperty,excludethatvaluefromthetypename.
Example:
Family: Air_Handling_UnitPackagedAcme_MechanicalSeries_I(3050Ton)
Types: 30TonElectricHeat208V/60Hz/3Ph
40TonNoHeat230V/60Hz/3Ph
RMCSG2.1page10
AIRHANDLINGUNITREPRESENTATIONSINSTANDARDVIEWS
TYPICALELEVATIONVIEW
ViewScale:
1/2=1=0(Imperial)
1:20(Metric)
Representationfeatures:
Minimaldetail,optimizedforperformance
TYPICALPLANVIEWCOARSE/MEDIUMDETAIL
ViewScale:
1/2=1=0(Imperial)
1:20(Metric)
Representationfeatures:
Minimaldetail,optimizedforperformance
RMCSG2.1page11
TYPICALPLANVIEWFINEDETAIL
ViewScale:
1/2=1=0(Imperial)
1:20(Metric)
Representationfeatures:
Moredetail
ModelLinesrepresentingadditionalunitfeatures
Origin:
InsertionPoint:LeftandBackCorner
RMCSG2.1page12
PREVIEWVIEW
Representationfeatures:
A3Dviewoftheairhandlingunit
TurnoffvisibilityofannotationcategoriesinVisibility/Graphics
SettheModelGraphicsStyletoShadingwithEdges
SetDetailLeveltoFine
UseaTemporaryHide/Isolatetohideanyconnectionobjects
NOTE:SeetheRevitModelContentStyleGuideforPreviewviewcreationguidelines.
RMCSG2.1page13
BESTPRACTICES
InadditiontotheguidelinespublishedintheRevitModelContentStyleGuide,usetheseMechanicalEquipment
specificbestpractices:
T YPE C ATALOGS
CreateatypecatalogforMechanicalEquipmentfamiliesthatcontainmorethansixtypes(sizes).
P ERFORMANCE
Donotmodelhiddenfacesorinternalcomponents.
Avoidmodelingcurvedsurfaceswherepossible.Onlymodelcurvedsurfaceswhereessentialtodepictthe
partdesign.
Avoidexcessiveuseofvoids,formulas,andarrays.
C ONNECTORS
Addadescriptionforeachconnector.Thedescriptionshoulddetailtheintentoftheconnector(for
example,HeatingWaterSupplyIn,HeatingWaterReturnOut,ChilledWaterSupplyIn,SupplyAir,Return
Air,etc).
RMCSG2.1page14
TESTINGGUIDELINES
UsetheseMechanicalEquipmentspecifictestingguidelinesasasupplementtothegeneraltestingguidelinesin
theRevitModelContentStyleGuide.
1.
Openatestproject:
Totestanimperialfamily,usetheMEP_AHU_Testing_Template_Imperialproject(includedinthe
downloadpackage).
Thetestprojectincludespredefinedsystems,rooms,andspacestotestthefamilysabilitytointerface
witheachkindofelement.Eachoftheviewsissettothecorrespondinglevelofdetail.Theprojectalso
includesCoarse,Fine,andMediumversionsofcertainviews.Theviewsaresetthiswaysoyoucanaddan
elementtooneview,andthenopenthetwootherviewstoinspecttheelementthedifferentlevelsof
detail.
RMCSG2.1page15
2.
Loadtheairhandlingunitfamilyinthetestproject:
Ifthefamilyusesatypecatalog,selectandloadallthefamilytypestoverifythattheyloadcorrectly.(To
selectalltypes,selectthefirsttype,pressandholdShift,andselectthelasttype.)
Inaplanview(Level1MechCoarse):
3.
Usingthedefaulttype(size)thatdisplaysintheTypeSelectorwhenyoustarttheMechanicalEquipment
command,placeanairhandlingunitintotheproject.
4. Testeachairhandlingunitinstance:
Checktheinsertionpointoftheairhandlingunit.
Verifythattheairhandlingunitconnectorobjectsfunctioncorrectlyformechanical,electricaland
piping.
Drawpipeorductofappropriateduct/pipetypefromeachconnector.
o Verifyappropriatephysicalconnectivityforeachpipe/duct.
o Verifythatallfiltersinthetestingenvironmentapplytoeachdrawnpipe/duct.
Createmechanical,piping,andelectricalsystemsandverifytheproperfunctionoftheunitineach
system.
EditelementpropertiesandverifythattheAHUupdatescorrectly.
5. RepeatSteps34,placingairhandlingunitsofthelargestandsmallesttypesinthefamilyintotheproject
space,andverifythattheconnectionsandsystemsareretained.
6. Forallairhandlingunitsinthetestproject:
OpentheCoarse,Fine,andMediumplanviews,andverifythateachairhandlingunitplan
representationdisplayscorrectlyinthedifferentlevelsofdetail.
Dimensiontoallexpectedreferencesandverifycorrectsnappingbehavior.
RMCSG2.1page16
Intheremainingviews(elevations,sections,3Dviews,preview):
7.
8.
InspecttheairhandlingunitineachviewinCoarse,Medium,andFinedetaillevels.
In3DView,inspecttheairhandlingunitgeometry:
SpintheairhandlingunitswiththeSteeringWheel,andverifythatallgeometryisconstrainedas
expected.
Checkforunconnectedgeometryand/orplanrepresentationsthatmaybedisconnectedfromthe
geometry.
ApplythefollowingModelGraphicsStyletotheview,andverifythatanymaterialsappliedtotheair
handlingunitdisplaycorrectly:
HiddenLine
ShadingwithEdges
Modifythematerialparameters,reapplytheHiddenLineandShadingwithEdgesgraphics
styles,andverifythechangeofmaterialsisrepresented.
9. Inelevationviews(North/South/East/West)andinthe3Dviews,verifythattheairhandlingunit
geometrydisplaysasexpected.
10. ThePreviewviewissettothecurrentview.
o
o
o
Inanyview:
11. Createamechanicalequipmentscheduleandverifytheairhandlingunitparameters(includingany
sharedparametersthatwereapplied)schedulecorrectly.
12. Selectanairhandlingunitinthetestproject,and:
Verifytheairhandlingunittypeproperties.
Checkallparameternamestoensuretheyadheretonamingconventionsanddonotcontainerrors.
Foreachmechanicalconnection:
13. EnsureproperconnectionofappropriateHVACcomponentstotheAHU.
Connectsupply,return,exhaustandoutsideairducttoairterminalsandVAVboxes.
Connecthydronicsupplyandreturnpipefortheheatingandchilledconnectionstopumps,chillers
andboilers.
o Forchilledwaterandheatingwaterconnections,createthelogicalhydronicsystem
separatelyfromthetestAHU,andthenconnecttheconnectionswithpipe.
o Forcondensatedrainconnections,createthelogicalsystemsfromthetestAHUassystem
typeSanitary,andthenconnecttheconnectionwithpipe.
RMCSG2.1page17
VerifythatairflowdataupdatesattheappropriateAHUconnector.
Theimperialtemplateincludes1diffuserforareturnairsystemat500CFMand2diffusersfora
supplyairsystemat500CFM/ea.
Modifytheairflowforatleastonecomponentconnectedtoeachmajorductrun.
Reverifytheairflowdata.
VerifythatflowdataupdatesattheappropriateAHUconnector.
Modifytheflowforatleastonecomponentconnectedtoeachmajorpiperun.
Reverifytheflowdata.
14. Ensurepropertransferofelectricaldatatoacircuitandpanel.
CreateapowercircuitforeachelectricalconnectorontheAHU.
Connectthecircuittoanappropriatepowerpanel.
Verifythatthenumberofpolesandapparentloadvaluesareproperlyreflectedinthepanelcircuit
manager.
ChangetheAHUpropertiestoanalternatetype.
Verifythattheelectricaldataupdatesasexpectedinthepowerpanel.
RMCSG2.1page18