Refrigerant
Cooling
Heat Exchanger
Location
IP Rating
Dew point indication
Condensate drain
Power supply
Compressed Air
Steel
RAL 9001 (white) powder-coated
RAL 5010 powder-coated
On the right side panel (inlet) & rear (outlet)
On the left side panel
On rear
Bypass
R134a
R404
R407c
Air-cooled
Water-cooled
Cooper tubes
Stainless steel plates
Indoors
IP 23
IP 44
Analogue gauge
Digital LED
Digital with alarm lamp
Digital with potential free alarm contact
Time-controlled condensate drain
R-DRAIN: Electronic level-controlled condensate drain
230V 1 Phase 50 Hz
400V 3 Phase 50 Hz
Other power supplies on request
315-820
1000-1200 1700
Design data*
Inlet pressure
Inlet temprature
Ambient temprature
Min.
2 bar(g)
+4C
+7C
Design
7 bar(g)
+35C
+25C
Max.
16 bar(g)
+49C
+43C
21-101
140-160
240-820 1000-1200
1700
max +55C max +55C
max +45C max +45C
* Please use the correction factors in the table on the back side of this page if the conditions are different from the design conditions.
Remeza refrigerant compressed air dryers are best used with a Remeza PF prefilter and a HF afterfilter.
Standard
www.remeza.com
Model
Capacity Connection
m3/h
" BSP
Height
Width
mm
Depth
Weight
kg
el. Connection
V/ph/hz
Power Consumption
kW
RFD 21
20
3/8
382
320
320
15
230/1/50
0.24
RFD 31
30
3/8
382
320
320
19
230/1/50
0.24
RFD 61
60
3/4
568
368
394
28
230/1/50
0.34
RFD 81
80
3/4
568
368
394
30
230/1/50
0.4
RFD 101
100
3/4
568
368
394
42
230/1/50
0.4
RFD 140
140
601
363
861
50
230/1/50
0.55
RFD 160
160
601
363
861
53
230/1/50
0.60
RFD 240
240
601
363
921
58
230/1/50
1.04
RFD 315
315
761
443
971
72
230/1/50
1.33
RFD 360
360
761
443
971
78
230/1/50
1.59
RFD 470
470
761
443
971
85
230/1/50
1.81
RFD 580
580
811
493
1151
100
230/1/50
2.32
RFD 680
680
811
493
1151
112
230/1/50
2.80
RFD 820
820
811
493
1251
134
230/1/50
2.95
RFD 100
1.000
2 1/2
1510
1129
857
266
400/3/50
2.55
RFD 1200
1.200
2 1/2
1510
1129
857
285
400/3/50
2.95
RFD 1700
1.700
1510
1129
857
335
400/3/50
5.70
The factors below need to be used to convert the actual operating conditions to the required dryer capacities.
Correction factors for different inlet pressure in bar(g) F1
bar(g)
3
4
5
6
7
8
9
10
11
12
13
14
RFD 21 - RFD 1700
0.79 0.87 0.92 0.96 1.00 1.03 1.07 1.10 1.13 1.16 1.18 1.21
Correction factors for different inlet temperatures in C (F2)
C
+35
+40
+45
RFD 21 - RFD 1700
1.00
0.84
0.71
+50
0.63
+55
0.55
+40
1.00
0.83
+45
1.00
0.78
Selection example:
Air volume at dryer inlet (V1)
Inlet pressure (F1)
Inlet temperature (F2)
Ambient temperature (F3)
V2
www.remeza.com
Calculation
:
:
:
:
: 850 m3/h
10 bar(g)
+45C
+35C
Required dryer capacity
V1
850
V2 =
=
= 1223m3/h
F1* F2* F3
1,1* 0,71* 0,89
Selected: RFD 1200
- 1635
2150 - 3500
656 - 1635
2150 - 3500
Design conditions
Min.
Operating pressure
2 bar (g)
Inlet air temperature
+4C
Ambient/cooling water temperature +7C
Design
7 bar (g)
+35C
+25C
Max.
16 bar (g)
+55C
+45C
In case the actual operating conditions vary from the design conditions, please use the correction factors on the
reverse side if this data sheet, for the right selection of your dryer.
Remeza refrigerant compressed air dryers are preferably installed with a Remeza PF (1 micron) dirt filter filter at
the inlet and a Remeza HF (0.01 micron) oil fine filter at the outlet of the dryer.
Standard
www.remeza.com
Model
Capacity
m3/h
Connection
" BSP
Height
Width
mm
Depth
Weight
kg
el. Connection
V/ph/hz
Power Consumption
kW
RFDx 656
1.750
DN 80
2162
1232
1030
520
400/3/50
4.90
RFDx 680
2.300
DN 100
2162
1243
1301
690
400/3/50
5.50
RFDx 818
2.600
DN 100
2162
1243
1301
690
400/3/50
7.00
RFDx 950
3.200
DN 150
2162
1400
1510
880
400/3/50
8.70
RFDx 1090
3.500
DN 150
2162
1400
1510
880
400/3/50
9.20
RFDx1365
4.650
DN 150
2162
1400
1510
1050
400/3/50
10.80
RFDx 1635
5.250
DN 150
2162
1400
1510
1200
400/3/50
13.40
RFDx 2150
7.400
DN 150
2462
1590
3245
1850
400/3/50
11.50
RFDx 2500
8.200
DN 200
2462
1590
3245
2000
400/3/50
13.80
RFDx 2800
9.500
DN 200
2462
1590
3245
2200
400/3/50
15.30
RFDx 3500
12.200
DN 200
2462
1590
3245
2600
400/3/50
17.70
+40
0.84
+45
0.71
+50
0.63
+55
0.55
+40
0.83
+45
0.78
Important: Correction factors marked with a * can result in increased pressure drop over the dryer.
All data are subject to alteration without prior notice. Please confirm factory for confirmation.
www.remeza.com
55-72
Design Data
Inlet pressure*
Inlet temperature*
Pressure dew point*
Ambient temperature
Relative humidity inlet air
Regeneration need
Minimum
4 bar g*
+5C*
-70C*
+2C
Design
7 bar g
+35C
-40C
+25C
100%
15%
Maximum
10 bar g*
+50C*
-20C*
+50C
2-36
55-72
* Please use the correction factors on the back if conditions are different from standard.
Maximum Operating pressure 16 bar: on request.
Standard
www.remeza.com
Model
Capacity
Dimensions
Weight
Filters ConnectionPressure drop Power cons.
m3/h*
A
B
C
Kg
HF/DF
BSP
bar
W
REDC 2
5.8
137
237
653
13
9/9
W
0.1
47
REDC 3
9.7
137
237
653
13
9/9
W
0.1
47
REDC 5
17.5
137
237
653
17
9/9
W
0.1
47
REDC 7
22.4
137
237
941
19
18/18
W
0.1
47
REDC 10
33.4
137
237
941
24
18/18
W
0.3
47
REDC 17
56.1
198
368
824
37
36/36
X
0.1
47
REDC 23
77.4
198
368
824
43
36/36
X
0.1
47
REDC 36
120.9
198
368
1325
64
54/54
X
0.3
47
REDC 55
183.1
477
415
1326
110
90/90
1W
0.2
64
REDC 72
241.4
477
415
1326
130
90/90
1W
0.3
64
*Nominal dryer capacity according to DIN ISO 7183, pressure dew point -40C
** Dimensions without filters
The capacity of the dryer is based on the intake volume of the compressor at 20C, 1 bar(a)
Subject to alteration without prior notice
The suitable desiccant dryer for non-standard operating conditions can be found
using the following correction factors.
Correction factor for different operating pressures in bar g (F1)
bar (g)
4
5
6
7
8
9
10
Correction factor (F1) 0.47 0.65 0.88 1.00 1.08 1.14 1.20
11
12
13
14
15
16
butor
+40
0.88
Selection example:
: 40 m3/h
: 10 bar (g)
: +40C
www.remeza.com
+50
0.60
-70
For a selection consult your distributor
Calculation
V2
+45
0.70
: -40C
V2=
V1
F1* F2* F3*
40
1,20* 0,88* 1,00
= 37,9m3/h
Selected: REDC17
For optimum performance, Remeza pre and after filters should be used.
Design Data
Inlet pressure*
Inlet temperature*
Pressure dew point*
Ambient temperature
Relative humidity inlet air
Purge air consumption
Minimum
4 bar g
+5C
-70C
+2C
Design
7 bar g
+35C
-40C
100%
15%
Maximum
10/16 bar g
+50C
-20C
+50C
Standard
www.remeza.com
Model
RED
RED
RED
RED
RED
RED
48
81
129
183
220
288
Capacity
m3/h *
160
270
430
610
735
960
A
750
750
750
750
750
750
Dimensions
B
750
1150
1150
1150
1150
1150
C
1955
1970
1980
1990
1990
2000
Weight Connection
Power cons.
kg
BSP
DIN Flange
kW
190
1
0.06
310
1 1/2
0.06
425
1 1/2
0.06
585
1 1/2
0.06
685
2
0.06
755
2
0.06
RED 360
1200
1300
1500
1930
1000
RED 445
1490
1400
1500
1950
1225
RED 540
1800
1450
1500
2070
1475
RED 635
2120
1500
1500
2090
1700
RED 750
2500
1700
1500
2190
1930
RED 865
2880
1750
1700
2220
2180
RED 1135
3790
1900
1950
2250
2315
RED 1785
5950
2120
2400
2390
3860
*Nominal dryer capacity according to DIN ISO 7183, pressure dew point -40C
80
80
80
80
100
100
100
150
0.06
0.06
0.06
0.06
0.06
0.06
0.06
0.06
The capacity of the dryer is based on the intake volume of the compressor at 20C, 1 bar(a)
Subject to alteration without prior notice
7 bar (g)
35C
Pressure
dewpoint
Drucktaupunkt
To calculate the capacity under the worst case operating conditions (lowest inlet pressure, highest inlet temperature, lowest required pressure dewpoint) please use the correction graph.
Deviations from these operating conditions might affect the performance of the dryer.
Inlet temperature(C)
0,78
www.remeza.com
- 308
385 - 1284
74 - 308
385 - 1284
For optimum performance, Remeza pre- and after filters should be used
Design data
inlet pressure
Inlet temperature
Pressure dew point
Ambient temperature
Relative humidity inlet air
Purge air consumption
minimum
4 bar (g)
design*
7 bar (g)
+5C
+35C
-40C
100%
2,2%
+5C
maximum
10 bar (g)*
16 bar (g)*
+50C
+50C
10
Standard
www.remeza.com
Model
Capacity
m3/h*
Dimensions (mm)
A
B
C
Weight
kg
RMWE 250
250
450
760
2170
300
1.7
3.6
RMWE 390
390
500
1000
2280
450
1 1/2
2.7
5.4
RMWE 655
655
550
1050
2620
670
1 1/2
3.6
7.2
RMWE 770
770
600
1200
2750
800
4.5
9.0
RMWE 1050
1050
650
1250
2750
950
5.4
10.8
RMWE 1295
1295
700
1400
3050
1300
80
7.2
14.4
RMWE 2020
2020
800
1550
3050
1900
80
10.8
21.6
RMWE 2300
2300
900
1650
3050
2110
80
12.6
25.2
RMWE 2600
2600
950
1850
3175
2400
100
14.4
28.8
RMWE 3650
3650 1050
1950
3175
3100
100
18.9
37.8
RMWE 4190
4190 1100
2000
3175
3400
100
22.5
45.0
*Nominal dryer capacity according to DIN ISO 7183, pressure dew point -40C
The capacity of the dryer is based on the intake volume of the compressor at 20C. 1 bar(a)
The following data can be used to convert the inlet conditions to the required dryer capacities:
Muliplier for different inlet pressures in bar (g) (F1)
bar (g)
4
5
6
7
8
9
10
Multiplier (F1)
0.63 0.75 0.88 1.00 1.12 1.15 1.37
Example
: 900 m3/h
: 10 bar (g)
: +40C
www.remeza.com
12
13
14
15
16
+35
1.00
+40
0.60
+45
0.38
+50
0.25
Calculation
V2
11
V2=
V1
F1* F2*
900
1,37* 0,60
= 1095m3/h
11
12
Minimum
5 bar (g)
+5C
+0C
Design
7 bar (g)
+35C
+25C
Maximum
10 bar (g)
+45C
+40C
www.remeza.com
Model
RDB
Capacity
Dimensions (mm)
(m3/h)*
Width ( A ) Depth ( B )
Height ( C )
Weight
(kg)
Connection
Power consumption
(Flange) Fan kW Heater kW Average kW
RDB-22
710
2160
1590
2925
1400
DN 80
6,6
RDB-23
985
2230
1590
2925
1500
DN 80
13,2
9,0
RDB-24
1675
2230
1590
2925
2000
DN 80
21,3
15,0
RDB-25
2180
2420
1590
2925
2400
DN 80
25,5
19,3
RDB-26
2595
2730
1890
2985
2900
DN 100
5,5
32,4
23,0
RDB-27
3385
2830
1890
2985
3500
DN 100
5,5
40,8
29,8
RDB-28
4620
3640
2550
3270
4700
DN 150
7,5
53,7
40,6
RDB-29
5540
3840
2450
3270
5900
DN 150
7,5
66,3
49,1
RDB-30
6860
3940
2520
3270
6900
DN 150
11
80,1
60,4
RDB-31
8310
4040
2520
3270
7700
DN 150
11
96,9
74,8
RDB-32
9370
5380
2425
3035
10500
DN 200
11
114
84,1
RDB-33
10885
5380
2425
3085
11500
DN 200
11
132
98,1
RDB-34
11915
5580
2545
3085
12500
DN 200
15
144
107,3
RDB-35
13550
5625
2595
3085
13500
DN 200
15
162
121,4
www.remeza.com
13
14
www.remeza.com
Sculpted Design
Covers flow ranges 34 to 2549 nm3/h
Flanged inlet and outlet connections make
installation easy
Thirteen flow models, with multiple port sizes
1/4 to 3 BSP, allow for greater application flexibility
Sculpted housing designs, with large unrestricted
flow paths, reduce pressure drop
Safety Built-In
Die cast aluminium housings provide a cost effective
solution in the 1750 to 2549 nm3/h flow range
Chromated housings, with a polyester epoxy powder
coating for corrosion resistance
Internally ribbed bowls facilitate condensate draining
Audible alarm when attempting bowl removal under
pressure
15
www.remeza.com
www.remeza.com
15
International Standards
for Test and Measuremet
ISO 12500
ISO 12500 defines a universal method for manufacturers to test and rate compressed air filters.
Critical performance parameters are specified for inlet
oil challenge and solid particulate size distribution.
ISO 12500-1 defines the testing of coalescing filters
for oil aerosol removal performance.
ISO 12500-2 quantifies vapor removal capacity of
adsorption filters.
Optional 02-17
Filter Clamps,
Wall Mount Brackets,
Gauges and
Condensate Drains
Available to maximize
performance!
ISO 8573.1:2009
Air QualIty Standard
R-DRAIN please
refer to page 18
Element Grade
Class Solids
ISO Quality
Class Oil
ISO Quality
S3
P3
H3
U3
C3
Wetted p
0,07 bar
0,10 bar
0,12 bar
0,14 bar
-
S3
1
3,0m
Remaining
Oil Content2 mg/m3
1
U3
C3
1,0m
0,01m
0,01m
0,01m
99,999+%
99,999+%
99,999+%
50%
80%
99,9+%
99,99+%
5,0
2,0
16
H3
99,999+%
P3
<
0,01
<
0,001
<
0,004
www.remeza.com
Inlet
Outlet
Model ConfIguration
R3 - - -
Housing-connection-Flow
Element Grade
Model Connection*
02
03
04
06
07
08
10
11
12
14
15
16
17
/8
1,0
1,5
1,5
2,0
2,5
2,5
3,0
3,0
Model
Flow
@ 7 bar g
34 m3/h
59 m3/h
85 m3/h
127 m3/h
175 m3/h
267 m3/h
437 m3/h
612 m3/h
681 m3/h
1317 m3/h
1750 m3/h
2039 m3/h
2549 m3/h
Flow capacity
S3
P3
H3
U3
C3
Optionens
T
D
P1
G1
M
X
Z1
Z2
Z3
W
Example: R3 02-S3-DP1
Flow and Connection:
34 m/h; R
Element Grade: SF - bulk liquid removal
Optionen:
Manual Drain
Internal Automatic Drain
Differential Pressure Slide Indicator
Differential Pressure Gauge
Electronic Filter Monitor
External Drain Adapter (02-12)
Electric Demand Drain SXD-1
Electric Demand Drain SXD-3
Electric Demand Drain SXD-10
External Mechanical Drain (14-17)
max. operating
pressure
[bar g]
Weight
Dimensions
B
[mm]
Connection
[kg]
A
[mm]
R302
34
16,0
0,8
113,6
205,5
171,4
102,0
1/4"
R303
59
16,0
0,8
113,6
205,5
171,4
102,0
3/8"
R304
85
16,0
0,9
113,6
252,0
216,4
102,0
1/2"
R306
127
16,0
1,4
132,0
262,1
219,8
127,0
3/4"
R307
175
16,0
1,4
132,0
262,1
219,8
127,0
3/4"
R308
267
16,0
1,6
132,0
326,1
283,8
127,0
1"
R310
437
16,0
3,8
200,0
336,7
276,1
178,0
1 1/2"
R311
612
16,0
4,5
200,0
433,7
373,1
178,0
1 1/2"
R312
681
16,0
5,3
200,0
566,0
505,4
178,0
2"
R314
1317
11,0
8,4
230,8
634,4
550,0
204,0
2 1/2"
R315
1750
11,0
8,4
230,8
634,4
550,0
204,0
2 1/2"
R316
2030
11,0
12,6
230,8
817,1
732,7
204,0
3"
R317
2549
11,0
28,7
230,8
1085,1
1000,7
204,0
3"
[ m/h*]
C
[mm]
D
[mm]
R / DN
Correction Factor
Operating Pressure
Multiplier
10
12
14
17
19
21
0,38
0,52
0,63
0,75
0,88
1,00
1,13
1,38
1,65
1,87
2,28
2,54
2,74
www.remeza.com
17
R-DRAIN
Capacitive Sensor
This monitors the level of condensate received from the
compressed air system and manages its effective discharge.
Durability (Hard-Wearing)
Rigid housing material, typically used in the aircraft industry
and semiconductor industry
Corrosion and abrasion resistant for a long life in
an industrial environment
Efficient design available for 7 models
Cast moulded and anodized housing design
Two sensors (low-level and high-level ) control the discharge of the condensate. The discharge valve closes
the outlet before there is any loss of the costly-produced
compressed air.
18
www.remeza.com
Model
RXD- 1
RXD- 3
RXD- 10
RXD- 30
RXD- 100
RXD- 300
RXD- 3 HP
Compressor Capacity
(m/min)
4 - 5,5
12 - 16,5
40 - 55
120 - 165
400 - 550
1200 - 1700
12 - 16,5
Refrigerated dryer*1
(m/min)
8,0- 11
24 - 33
80 - 115
240 - 330
800 - 1150
2300 -3250
24 - 33
Filter-downstream*2
(m/min)
40 - 55
120 - 165
400 - 550
1200 - 1600
Min. / Max.
Operating Pressure (bar)
0,8 - 16
0,8 - 16
0,8 - 16
0,8 - 16
0,8 - 16
0,8 - 16
0,8 - 50
Min. /Max.
Operating Temperature (C)
+ 1 - + 80
+ 1 - + 80
+ 1 - + 80
+ 1 - + 80
+ 1 - + 80
+ 1 - + 80
+ 1 - + 80
Voltage (V AC)
90 - 250
90 - 250
90 - 250
90 - 250
90 - 250
90 - 250
90 - 250
Frequency (Hz)
50 - 60
50 - 60
50 - 60
50 - 60
50 - 60
50 - 60
50 - 60
Condensate
oil-contaminated + oil-free
Capacity
Housing
Aluminium, hard-coated
Condensate inlet
2 x "
2 x "
Condensate outlet
Weight (Kg)
3 x "
120 - 16
1 x 1" + 2 x "
2 x "
1x"
1,10
1,45
2,10
1x "
2,40
4,10
6,50
1,85
*1 referred to 1 bar(a) and 20C at 7 bar working pressure, compressor inlet 25C at 60% r.H.,
compressor discharge temperature 35C, dew-point dryer 3C
*2 Condesate aftercooler or fridge dryer already removed.
Capacity depends on different climate zones
Options on request
Technical Alterations reserved
Piping
www.remeza.com
Receiver / Tank
Air Dryer
Compressor
19
Oil
5
H3
HIT
COMPRESSOR
Moisture
6
Solids
1
Moisture
6
Oil
1
H3
Moisture
4
Oil
1
S3
RFD
Solids
1
Moisture
4
Oil
1
Food packaging,
cosmetics, photo labs,
textile looms
P3 & H3
Solids Moisture
1
2-5
Thelephone cable,
printing, photo labs, spray
painting, dental, laboratory
instrumets
RMD
RED
Oil
1
Solids
2
P3
Moisture
1-3
Oil
1
Moisture
2-3
Oil
1
RDB