MANUAL CODE HDBK P/N 3AL 97279 ABAA Ed.01 TQCVA

1642 Edge Multiplexer Rel.


INSTALLATION HANDBOOK

ORIGINAL MSWORD: FILE ARCHIVE: cod ANV (PD1PD2)


-

Total number of pages for archivage: 2+50=52

ASSEMBLY INSTRUCTIONS
-

RECTO VERSO PRINTING


HANDBOOK COMPOSITION AND ASSEMBLY:
step

1
2
3

No pages
LABELS
FRONT
HANDBOOK

2
48
TOTAL A4 PAGES:
TOTAL A4 SHEETS:

50
25

WARNING FOR AUNITS OTHER THAN AITALY

Labels are done according to AItaly binder format.

Source file: MSWORD-OFFICE PROFESSIONAL 2000


The data below will be used for the labels:

1642 Edge Multiplexer Rel.3.0


.
STM-4/1 Multi-Service Edge Multiplexer
for Customer Premises
.
INSTALLATION HANDBOOK

3AL 97279 ABAA Ed.01 TQCVA

VOL. 1/1

1/2
3AL 97279 ABAA Ed.01 TQCVA

numbered
from
to

1/48

48/48

1642 Edge Multiplexer Rel.


.
STM-4/1 Multi-Service Edge Multiplexer
for Customer Premises
.

INSTALLATION HANDBOOK
3AL 97279 ABAA Ed.01 TQCVA

VOL. 1/1
1642 Edge Multiplexer Rel.0
.
STM-4/1 Multi-Service Edge Multiplexer
for Customer Premises

INSTALLATION HANDBOOK
3AL 97279 ABAA Ed.01 TQCVA

VOL. 1/1
1642 Edge Multiplexer Rel.
STM-4/1 Multi-Service Edge Multiplexer
for Customer Premises
.
3AL 97279 ABAA Ed.01 TQCVA - INSTALLATION HANDBOOK VOL. 1/1

1642 Edge Multiplexer Rel.


STM-4/1 Multi-Service Edge Multiplexer
for Customer Premises
3AL 97279 ABAA Ed.01 TQCVA - INSTALLATION HANDBOOK VOL. 1/1

1642 Edge Multiplexer Rel.


.
STM-4/1 Multi-Service Edge Multiplexer
for Customer Premises
.
3AL 97279 ABAA Ed.01 TQCVA - INSTALLATION HANDBOOK VOL. 1/1

END OF INTERNAL DOCUMENT1

2/2
3AL 97279 ABAA Ed.01 TQCVA

Installation Handbook

Alcatel 1642 Edge


Multiplexer
STM 4-1 Multi-Service Edge Multiplexer for Customer Premises

1642 Edge Multiplexer Rel.3.0

3AL 97279 ABAA Ed.01 TQCVA

RELATED TECHNICAL HANDBOOK:


HANDBOOK
1642 Edge Multiplexer Rel. 3.0 Technical Handbook

ANV Part No.


3AL 97279 ABAA Ed.01 TQCVA

SAFETY RULES
Before carrying out any installation, turn-on, tests & operation and maintenance operations, read
carefully the Safety Rules described in Technical Handbooks section HANDBOOK GUIDE.

HANDBOOK COMPOSITION (present edition)


part
1

No pages
48

HANDBOOK

3AL 97279 ABAA Ed.01 TQCVA

Numbered
From
1/48

to
48/48

ALCATEL 1642 EDGE MULTIPLEXER


INSTALLATION GUIDE

01

2006-04-05

First Edition

Wu Jie, Chang HaiYan


Lennart Priester

Tian Zhaoyong, Liang Min

ED

DATE

CHANGE NOTE

APPRAISAL AUTHORITY

ORIGINATOR

Rel 3.0
1642EDGE MULTIPLEXER INSTALLATION GUIDE
ED

01
3AL 97279 ABAA TQCVA

1/48

TABLE OF CONTENTS
1

UNPACKING AND WAREHOUSING .......................................................................................................5


1.1 General..................................................................................................................................................5
1.2 Unpacking..............................................................................................................................................6
1.2.1 Preliminary checks........................................................................................................................6
1.2.2 Unpacking.....................................................................................................................................6
1.3 Warehousing .........................................................................................................................................7

MECHANICAL INSTALLATION ...............................................................................................................7


2.1 Installation kits for 1642 Edge Multiplexer.............................................................................................7
2.2 Installation on a 19 inches-width rack (600mm deep)...........................................................................7
2.3 Installation on a 21 inches-width rack (600mm deep)...........................................................................9
2.4 Installation on a 21 inches-width rack (300mm deep horizontal) ........................................................10
2.5 Installation on a 21 inches-width rack (300mm deep angle)...............................................................11
2.6 Installation on a wall ............................................................................................................................13
2.7 Installation of kit cable support............................................................................................................15
2.8 Installation and rinsing of filter.............................................................................................................16

ELECTRICAL AND OPTICAL INSTALLATION.....................................................................................17


3.1 Power supply connection ....................................................................................................................20
3.1.1 Feeding main 24V/-48V DC power from DC48B......................................................................20
3.1.2 Feeding backup 24V/-48V DC power from Fan Board (-24V/-48V) .........................................20
3.1.3 Feeding 220V~240V AC power from AC220B ...........................................................................22
3.1.4 Take away the 220V~240V AC power from AC220B.................................................................23
3.1.5 Power supply typical configuration .............................................................................................24
3.2 F interface connection for local/remote Craft Terminal .......................................................................25
3.3 STM-1 Optical fiber connection ...........................................................................................................26
3.4 STM-1 Electrical interface connection.................................................................................................27
3.5 2Mbit/s tributary connections...............................................................................................................28
3.5.1 2MBit/s interface connection of E1RCB8 board .........................................................................29
3.5.2 2MBit/s interface connection of E1B28 and SE1B28 boards .....................................................31
3.5.3 2MBit/s interface connection of E1B8 and SE1B8 boards .........................................................32
3.5.4 2MBit/s interface connection of DE1B28 and SDE1B28 boards................................................33
3.5.5 2MBit/s interface connection of DE1B8 and SDE1B8 panels ....................................................34
3.5.6 2MBit/s interface connection of DE1JB8 and panels .................................................................35
3.5.7 2MBit/s interface connection of DE1B32 boards........................................................................36
3.6 34MBit/s and 45MBit/s tributary connections ......................................................................................37
3.7 Ethernet interface connection..............................................................................................................38
3.7.1 Ethernet electrical interface ........................................................................................................38
3.7.2 Ethernet optical interface............................................................................................................39
3.8 2048Kbit/s, 75 Ohm clock connection.................................................................................................40
3.9 Auxiliary data and houseKeeping connections on Main Board...........................................................41
3.10 Debug interface connection.................................................................................................................42
3.11 Q interface connection ........................................................................................................................43
3.12 OW Interface .......................................................................................................................................44
3.12.1 Assembly and disassembly the EOW board ..............................................................................44
3.12.2 OW Interface connection ............................................................................................................45

ANNEXES ...............................................................................................................................................46
4.1 Annex 1 - Parts making up the Installation set....................................................................................46
4.2 Annex 2 - Installation Cables...............................................................................................................47
4.3 Annex 3 - Suggested cabling ..............................................................................................................48

ED

01
3AL 97279 ABAA TQCVA

2/48

LIST OF TABLES AND FIGURES


Tables
Table 1 - Front View LEDs............................................................................................................................... 18
Table 2 - Slot numbers and use....................................................................................................................... 18
Table 3 - Power supply typical configuration ................................................................................................... 24

Figures
Figure 1 - Installation on a 19 inches-width rack (600mm deep)....................................................................... 8
Figure 2 - Path for electrical and optical cabling (600mm deep) ....................................................................... 8
Figure 3 - Installation on a 21 inches-width rack (600mm deep)....................................................................... 9
Figure 4 - Installation on a 21 inches-width rack (300mm deep horizontal) .................................................... 10
Figure 5 - Path for electrical and optical cabling (300mm deep horizontal) .................................................... 11
Figure 6 - Installation on a 21 inches-width rack (300mm deep angle) ........................................................... 12
Figure 7 - Path for electrical and optical cabling (300mm deep angle) ........................................................... 12
Figure 8 - Holes position on a wall .................................................................................................................. 13
Figure 9 - Installation on a wall ........................................................................................................................ 14
Figure 10 - Installation of kit cable support ...................................................................................................... 15
Figure 11 - Installation of filter.......................................................................................................................... 16
Figure 12 - Rinse the filter................................................................................................................................ 16
Figure 13 - Front View of 1642 Edge Multiplexer ............................................................................................ 18
Figure 14 - 1642 Edge Multiplexer slot numbers (Rear).................................................................................. 18
Figure 15 - Connection Points on the rear of 1642 Edge Multiplexer.............................................................. 19
Figure 16 - DC -24V/-48V Power supply connection through DC48B ............................................................. 20
Figure 17 - DC -24V/-48V Power supply connection through FB .................................................................... 21
Figure 18 - 220V~240V AC Power supply connection through AC220B......................................................... 22
Figure 19 - Install the magnetic ring on the power supply cable ..................................................................... 22
Figure 20 - AC220B Plug out ........................................................................................................................... 23
Figure 21 - F management interface connection ............................................................................................. 25
Figure 22 - STM-1 optical fiber connection...................................................................................................... 26
Figure 23 - EMC COVER (STM1 ELECTRICAL INTERFACE)....................................................................... 27
Figure 24 - E1 signal connection of E1RCB8 board ........................................................................................ 29
Figure 25 - 2Mbit/s extended signal connection .............................................................................................. 30
Figure 26 - 2Mbit/s interface definition of E1B28 and SE1B28 boards ........................................................... 31
Figure 27 - 2Mbit/s interface definition of E1B8 and SE1B8 boards ............................................................... 32
Figure 28 - 2Mbit/s interface definition of DE1B28 and SDE1B28 boards ...................................................... 33
Figure 29 - 2Mbit/s interface definition of DE1B8 and SDE1B8 boards .......................................................... 34
Figure 30 - 2Mbit/s interface definition of DE1JB8 boards .............................................................................. 35
Figure 31 - 2Mbit/s interface definition of DE1B32 board................................................................................ 36
Figure 32 - 34Mbit/s and 45Mbit/s interfaces connection ................................................................................ 37
Figure 33 - Ethernet electrical interface connection ........................................................................................ 38
Figure 34 - Ethernet optical interface connection ............................................................................................ 39
Figure 35 - 2Mbit/s, 75 Ohm clock interface connection ................................................................................. 40
Figure 36 - Auxiliary Data and HouseKeeping connections on MB................................................................. 41
Figure 37 - Connection of DBGL interface....................................................................................................... 42
Figure 38 - Connection of Q interface.............................................................................................................. 43
Figure 39 - Assembly and disassembly the EOW board ................................................................................. 44
Figure 40 - Connection of OW interface .......................................................................................................... 45

ED

01
3AL 97279 ABAA TQCVA

3/48

INSTALLATION
This document is available for 1642EM R3.0.

ATTENTION

EMC NORMS

WHEN CARRYING OUT THE GIVEN OPERATIONS OBSERVE THE NORMS STATED
in the Handbook Guide section of Technical Handbook.
1642EM product all meet with ETSI EN 300386 V1.3.3 Class B qualification (Other than
Telecommunication Center) except the PartNumber list following:
3AL97083BDAA (STM1 ELECTRICAL UNIT board) can meet with and Class A
qualification (Telecommunication Center) only.

SAFETY RULES

1642EM product is CLASS I LASER PRODUCT compliant with IEC 60825.


Carefully observe the front-panel warning labels prior to working on optical
connections while the equipment is in-service.
220V~240V parts of the power supply AC 220B are free accessible on the
solder side, as well on the component side (top of charging capacitor). For
protection against electric shock of the service personell, the service
personell is directed to remove the 220V~240V power supply cord before
removing the power supply AC 220B, or removing the board next left from
the AC 220B". For details about the removing of the power supply AC220B
see 3.1.4

ED

01
3AL 97279 ABAA TQCVA

4/48

UNPACKING AND WAREHOUSING

1.1 General
The following procedures have been issued and must be observed when unpacking the equipment.
The reciprocal operation must be done for repacking. In such case it is recommended to use the original
packing material.
The following sturdy outer packing material is utilized in order to protect the equipment against mechanical
and climatic stresses to which they are subjected:
wooden crates

for transport by ship, air, on road for periods longer than 60 days

ply-wood crates

for transport by ship, air, on road for periods of 30 to 60 days

cardboard boxes

for transport by air or on road for periods of less than 30 days

The 1642EMUX equipment meet with the following CE specification:


ETSI EN 300386
ETSI EN 300019
IEC 60950/60825

for
for
for

EMC/EMI Class B**


Environment
Safety

N.B. **STM-1 electrical interface meet to EMC/EMI Class A qualification only.

ED

01
3AL 97279 ABAA TQCVA

5/48

1.2 Unpacking
1.2.1 Preliminary checks
The following information should be printed on the outer crate:

International symbols
side up :

keep dry

fragile

layers

trade mark/address of the manufacturing company;


labels (or templated marks) indicating information on the contract and destination site of the
product;
an envelope holding among others the packing list

Upon receipt check:

that the final destination of the crates is that indicated on the label;
that no damage was made to the cases

Report any shipping damages to the Companys representative or the Shipping Agent.
1.2.2 Unpacking
When having to unpack proceed as follows:

symbol
make sure that the packing has been properly positioned, refer to the
open the case;
remove the shockproof material;
remove the goods from the case;
remove prepacking, the polyethylene bag and any other protection;
remove the plastic bags cellotaped to the rack and containing accessories;
remove the dehydrating bags;
ascertain that the goods are not damaged and that they correspond to those indicated on the
packing list enclosed in the envelope. Conversely, contact the agencys representative.

N.B.

ED

When unpacking it is advisable to handle the packing material with care; it might be reused
for packing again if it must be reshipped.

01
3AL 97279 ABAA TQCVA

6/48

1.3 Warehousing
If having to store the packed material, the following requirements must be met:

the cardboard boxes must be placed indoors in airy rooms;


the wooden or plywood cases can be placed outdoors, provided they are protected against rain
and direct sunlight.

Mechanical installation

FIXING THE UNITS (AND MODULES) INTO THE SUBRACK


(caution to avoid equipment damage)
The screw tightening torque for fixing the units (and modules, if any and if fixed by screws) into the
subrack must be:

2.8 kg x cm (0.28 Newton x m) 10 %


Exceeding this value may result in screw breaking.

2.1 Installation kits for 1642 Edge Multiplexer


Annex 1. - Parts making up the Installation set on page 46 shows all the installation kits and their
composition related to the expected installation types.
The number in column ref. Are the reference number used in the following paragraphs.

2.2 Installation on a 19 inches-width rack (600mm deep)


(See Figure 1 and Figure 2 on page 8).
The items to be used for this installation are included in the Adapter for 19 Rack: 3AL 97102 ABAA (Annex
1. - Parts making up the Installation set on page 46).
This installation allows to place the 1642 Edge Multiplexer on a 19 rack (600mm deep). The 1642 Edge
Multiplexer is housed in this rack with rear access of electrical and optical cabling, which is illustrated in
Figure 2.

ED

Fix the two 19 adapters (2) to the 1642 Edge Multiplexer (1) by four stainless screws (3).
Fix the equipment to the 19 rack through four screws, plastic washers (4) and four nuts (5).

01
3AL 97279 ABAA TQCVA

7/48

Figure 1 - Installation on a 19 inches-width rack (600mm deep)

Figure 2 - Path for electrical and optical cabling (600mm deep)

ED

01
3AL 97279 ABAA TQCVA

8/48

2.3 Installation on a 21 inches-width rack (600mm deep)


(See Figure 3 on page 9)
The items to be used for this installation are included in the Adapter for 21 Rack: 3AL 97102 AAAA (Annex
1. - Parts making up the Installation set on page 46).
This installation allows to place the 1642 Edge Multiplexer on a 21 rack (600mm deep). The 1642 Edge
Multiplexer is housed in this rack with rear access of electrical and optical cabling, which is illustrated in
Figure 2.

Fix the two 21 adapters (2) to the 1642 Edge Multiplexer (1) by four stainless screws (3).

Fix the equipment to the 21 rack through four screws, plastic washers (4) and four nuts (5).

Figure 3 - Installation on a 21 inches-width rack (600mm deep)

ED

01
3AL 97279 ABAA TQCVA

9/48

2.4 Installation on a 21 inches-width rack (300mm deep horizontal)

(See Figure 4 on page 10 and Figure 5 on page 11)


The items to be used for this installation are included in the Adapter for 21 Rack: 3AL 97102 AAAA (Annex
1. - Parts making up the Installation set on page 46).
This installation allows to place the 1642 Edge Multiplexer on a 21 rack (300mm deep horizontal). The 1642
Edge Multiplexer is housed in this rack with front access of electrical and optical cabling, which is illustrated
in Figure 7.

Fix the two 21 adapters (2) to the 1642 Edge Multiplexer (1) by four stainless screws (3).
Fix the equipment to the 21 rack through four screws, plastic washers (4) and four nuts (5).

Figure 4 - Installation on a 21 inches-width rack (300mm deep horizontal)

ED

01
3AL 97279 ABAA TQCVA

10/48

Figure 5 - Path for electrical and optical cabling (300mm deep horizontal)

2.5 Installation on a 21 inches-width rack (300mm deep angle)


(See Figure 6 and Figure 7 on page 12)
If to install the rack refer to Figue6-7, a vertical height of 300mm will be needed.
The items to be used for this installation (45)are included in the Angle adapter for 21 Rack (30mm width),
3AL 97142 AAAA (Annex 1. - Parts making up the Installation set on page 46).
This installation allows to place the 1642 Edge Multiplexer on a 21 rack (300mm deep angle). The 1642
Edge Multiplexer is housed in this rack with front access of electrical and optical cabling, which is illustrated
in Figure 7.

ED

Fix the Angle adapter for 21 Rack (300mm width) (2) to the 1642 Edge Multiplexer (1) by four
stainless screws (3).
Fix the equipment to the 21 rack through four screws, plastic washers (4) and four nuts (5).

01
3AL 97279 ABAA TQCVA

11/48

Figure 6 - Installation on a 21 inches-width rack (300mm deep angle)

Figure 7 - Path for electrical and optical cabling (300mm deep angle)

ED

01
3AL 97279 ABAA TQCVA

12/48

2.6 Installation on a wall


(See Figure 8 on page 13 and Figure 9 on page 14)
The items to be used for this installation are included in the Adapter for Wall Mount: 3AL 97102 ACAA
(Annex 1. - Parts making up the Installation set on page 46).
This installation allows to place the 1642 Edge Multiplexer on a wall.

Fix the two wall kit adapters (2) to the 1642 Edge Multiplexer (1) by four stainless screws (3).
Fix four M6 expansion bolts (4) on the wall. Refer to Figure 8 for the positions for hole drilling.
Fix the equipment to the wall through four lock washers (6), four plain washers (7) and four M6
nuts (5).

Figure 8 - Holes position on a wall

ED

01
3AL 97279 ABAA TQCVA

13/48

Figure 9 - Installation on a wall

N.B. Installation on a wall in 90 degree rotated is not the recommended method because of the safety
consideration.

ED

01
3AL 97279 ABAA TQCVA

14/48

2.7 Installation of kit cable support


(See Figure 8 on page 13)
The items to be used for this installation are included in the Kit Installation cable support: 3AL 97169 AAAA
(Annex 1. - Parts making up the Installation set on page 46).
The kit cable support (3AL97169AAAA) is installation parts separateness ,it can be installed into 21 inch rack
directly. And the installation mode must reference the installation mode of 1642EMUX equipment ,keep the
install face of the cable support same as the ware export face of 1642EMUX equipment.
The items to be used for this installation are included into kit cable support (3AL97169 AAAA),
Fix four pack nuts (1) (specific rack installation) to rack
Fix the cable support (3) to rack by four stainless steel screws M6 .(2).

N.B. The cable support has been smoothed without burr.

2
3

Figure 10 - Installation of kit cable support

ED

01
3AL 97279 ABAA TQCVA

15/48

2.8 Installation and rinsing of filter


Remove the filter from the shelf according to Figure 11

Figure 11 - Installation of filter

Unscrew the screw(1) and take out the net of filter (2), see Figure 12
Rinse and dry the net of filter (2)
Put the net of filter(2) back and fix the screw
Insert the filter back to the shelf according to Figure 11
N.B. It is required to clean the filter every 3 month; this period can be shorter depending on the
location environmental conditions.

Figure 12 - Rinse the filter

ED

01
3AL 97279 ABAA TQCVA

16/48

Electrical and optical installation

SAFETY RULES

The whole installation must be executed without powering the equipment.


Protection ground connection must be the first operation
Power Supply connection must be the last to be executed.
FIXING THE UNITS (AND MODULES) INTO THE SUBRACK
(caution to avoid equipment damage)
The screw tightening torque for fixing the units (and modules, if any and if fixed by screws) into the
subrack must be:

2.8 kg x cm (0.28 Newton x m) 10 %


Exceeding this value may result in screw breaking.
The electrical and optical connections are directly wired on the rear side of 1642 Edge Multiplexer through
connectors on the Main Control Board and the tributary boards.
Figure 13 on page 18 illustrates the LEDs on the front panel of 1642 Edge Multiplexer.
Table 1 on page 18 explains each LED on the front panel.
Figure 14 on page 18 and Figure 15 on page 19 illustrate the connection points and slot numbering of 1642
Edge Multiplexer.
Table 2 on page 18 reports the number of each slot and which boards the slot can contain.
Each paragraph also indicates:

pin assignment table

information on the adaptors/connectors supplied with the equipment to be mounted on the relevant
terminal tagblocks.
Annex 1. - Parts making up the Installation set on page 46 shows the parts making up the installation sets.
Annex 2 - Installation cables on page 47 shows the standard cables provided by the factory.
Annex 3 - Suggested cabling on page 48 shows the cables suggested to set-up the connections.
The tables associated to each terminal tagblock also refer to these cables.

ATTENTION:
The equipment is supplied with several connectors. The installer must respect the ESD
precautions presented in the Technical Handbook.
The final equipment configuration can result with empty slots. In this case it is recommended to
cover the empty slots with the DUMMY PLATE 3AL 97082 AAAA. This is necessary for correct
EMI-EMC performances.

ED

01
3AL 97279 ABAA TQCVA

17/48

N.B. Please ensured all boards plug in the subrack has been fixed by two fix-screws use screwdriver.

Figure 13 - Front View of 1642 Edge Multiplexer

LED
1
2
3

Color
Green
Yellow
Red

Meaning
Power on
Normal Alarm
Severe Alarm

Table 1 - Front View LEDs

Figure 14 - 1642 Edge Multiplexer slot numbers (Rear)

Slot number
1
2-5
6
7
8

Unit
Main Board
Tributary board*
-24V/-48V DC Power Interface Board, 220V~240V AC Power Interface Board
Fan Board (-24V/-48V access), Standard Fan Board
Air filter

Table 2 - Slot numbers and use

ED

01
3AL 97279 ABAA TQCVA

18/48

ISA-ES1 3FE/8FE
Slots 2,3,4,5
E3B1 or DS3B1
Slots 2,3,4,5

E1B28 or DE1B28
Slots 2,3,4,5

DE1B32
Slots 2,3,4,5

E1B8 or DE1B8
Slots 2,3,4,5

E1RCB8
Slots 2,3,4,5

OT1B1/ET1B1
Slots 2,3,4,5

As alternative

Figure 15 - Connection Points on the rear of 1642 Edge Multiplexer

ED

01
3AL 97279 ABAA TQCVA

19/48

3.1 Power supply connection


The 1642 Edge Multiplexer equipment can host two different types of power interface boards that are
inserted in slot 6 to meet different power requirements. One is DC48B board for the main DC 24V/-48V
power supply. The other is AC220B board for AC 220B power supply.
Additionally, a special FAN board (FB) can provide a backup 24V/-48V DC power supply interface.
N.B. Please ensured the power switch has been turned off and power supply cable has been moved if
you want to plug in and plug out the AC220B, DC48B and FB board.
N.B. Please ensured all boards plug in the subrack has been fixed by two fix-screws use screwdriver.
N.B. Only the -24V box 3AL97081ADAA can support 24V power supply.
N.B. The -24V box 3AL97081ADAAcan not support AC220B power supply.
3.1.1 Feeding main 24V/-48V DC power from DC48B
(See Figure 16)

Insert DC48B (4) into slot 6


Fix DC48B through the two screws (5).
Connect the power supply cable 3AL97109A* (ref 18-21, Annex2 installation cable) to the power
module and fix it.
Insert the connectors into the terminal tagblocks. Make sure that the cable is fixed correctly to the
DC48B.

a.
Figure 16 - DC -24V/-48V Power supply connection through DC48B

3.1.2 Feeding backup 24V/-48V DC power from Fan Board (-24V/-48V)


There is an additional choice to feed from -24V/-48V DC station battery through the Fan Board -24V/-48V
(FB) see Figure 17.

ED

Insert Fan Board (4) into slot 7


Fix Fan Board to the shelf through the two screws (5)
Connect the power supply cable 3AL97109A* (ref 18-21, Annex2 installation cable) to the power
module and fix it.
Insert the connectors into the terminal tagblocks. Make sure that the cable is fixed correctly to the
Fan Board (-24V/-48V).

01
3AL 97279 ABAA TQCVA

20/48

Figure 17 - DC -24V/-48V Power supply connection through FB

ED

01
3AL 97279 ABAA TQCVA

21/48

3.1.3 Feeding 220V~240V AC power from AC220B


(See Figure 18)

Insert AC220B (1) into slot 6

Fix AC220B through the two screws (2) with a crossed screwdriver

Install the magnetic ring (with AC board 3AL97077ABAA and 3AL97077ACAA) on the power
supply cable as Figure 19

Insert the power supply cable 3AL97087AAAA (ref 1, Annex2 installation cable) to the supply
socket.

Connect the other side of power supply cable to the power module and fix it well.

Turn on the switch.

Figure 18 - 220V~240V AC Power supply connection through AC220B

Figure 19 - Install the magnetic ring on the power supply cable

ED

01
3AL 97279 ABAA TQCVA

22/48

SAFETY RULES

In general:
Due to possible very high currents in case of short-circuit at the power input, it is
essential that the power distribution line shall be provided with a short circuit backup protection with adequate breaking capacity.
Make sure that the screws on the power modules (DC48B, FB (-48V) and AC220B)
are not loose when you insert or remove the cable from the power modules.

3.1.4 Take away the 220V~240V AC power from AC220B


(See Figure 20)

Turn off the switch.

Put away the power supply cable 3AL97087AAAA (ref 1, Annex2 installation cable) from the
supply socket.

Screw off two screws with a crossed screwdriver

Plug in an extractor (with AC board 3AL97077ABAA and 3AL97077ACAA) into the hole beside the
socket, rotate 90 degree, and then pull out the AC220B.

Figure 20 - AC220B Plug out

ED

01
3AL 97279 ABAA TQCVA

23/48

3.1.5 Power supply typical configuration


Power supply
Only -48V or -24V DC
feeding
Only
220V~240V
AC
feeding
Two -48V or -24V DC
feeding

Board
DC48B
SFB
AC220B
SFB
DC48B
FB

Slot
6
7
6
7
6
7

220V~240V AC and -48V


DC feeding

AC220B
FB

6
7

Description
-48V or -24V DC power supply
Fan board
220V~240V AC power supply
Fan board
-48V or -24V DC power supply (main)
Fan board with -48V or -24V DC power supply
(backup)
220V~240V AC power supply (main)
Fan board with -48V DC power supply (backup)

N.B. Only the -24V box 3AL97081ADAA can support 24V power supply.
N.B. The -24V box 3AL97081ADAAcan not support AC220B power supply.
Table 3 - Power supply typical configuration

ED

01
3AL 97279 ABAA TQCVA

24/48

3.2 F interface connection for local/remote Craft Terminal


The F management interface is located on the front panel of the main control board (inserted in slot 1). Its a
DB9 female connector, marked F.
The F management interface and the PC serial interface are connected via a serial cable 3AL97090A*
(Annex2 installation cable). The cable has a connector DB9 male (connected to the F interface) and a
connector DB9 female (connected with PC serial interface), as shown in Figure 21 (including pin-layout).

F
1

F interface
signals
(refer to NE)
CD
RXD
TXD
DTR
GND

DB9 connected
to main board
(male)
1
2
3
4
5

DB9 connected
to PC (female)
1
2
3
4
5

Figure 21 - F management interface connection

ED

01
3AL 97279 ABAA TQCVA

25/48

3.3 STM-1 Optical fiber connection


The SC/PC optical fiber connector is used for the connection of the STM-1 optical fiber interface, as shown in
Figure 22:

(1)

(2)

(3)

(4)

(5)

On the OT1B1 board:


(1) Panel LED
(2) RJ11 connector for accessing the transparent channel using the F1 byte
(3) RJ11 connector for accessing the transparent channel using the E2 byte
The overhead bytes can be accessed via the data cable 3AL97089A* (annex 2 installation cables).
One end of the cable has a RJ11 connector. The other end is a DB9 female connector.
N.B. RJ11 here are dedicate ports for E2/F1 function, DO NOT CONNECT THEM TO PSTN NETWORK.
1
6

Signal
name
RXD
TXD
GND

RJ11
connector
2
3
5

DB9
connector
3
2
5

(4) SC/PC optical fiber connectors, RX = receiving side


(5) SC/PC optical fiber connectors, TX = transmitting side

Figure 22 - STM-1 optical fiber connection

ED

01
3AL 97279 ABAA TQCVA

26/48

3.4 STM-1 Electrical interface connection


The 1.0/2.3 coaxial cable is used for the connection of the STM-1 electrical interface, as shown in Figure 23:

(1)

(2)

(3)

(4)

(5)

On the ET1B1 board:


(1) Panel LED
(2) RJ11 connector for accessing the transparent channel using the F1 byte
(3) RJ11 connector for accessing the transparent channel using the E2 byte
The overhead bytes can be accessed via the auxiliary data cable 3AL97089A* (annex 2
installation cables). One end of the cable has a RJ11 connector. The other end is a DB9 female
connector.
N.B. RJ11 here are dedicate ports for E2/F1 function, DO NOT CONNECT THEM TO PSTN NETWORK.
1
6

Signal
name
RXD
TXD
GND

RJ11
connector
2
3
5

DB9
connector
3
2
5

(4) 1.0/2.3 coaxial connector, RX = receiving side


(5) 1.0/2.3 coaxial connector, TX = transmitting side

In order to get better EMC performance, additional shield cover (3AL97220ABAA) for coaxial
cable is required.

Figure 23 - EMC COVER (STM1 ELECTRICAL INTERFACE)


ED

01
3AL 97279 ABAA TQCVA

27/48

3.5 2Mbit/s tributary connections


1642 Edge Multiplexer equipment provides 9 types of E1 service interface boards to meet different user
requirements. The board types are the following:

E1RCB8
8-channel E1 (2MBit/s) coaxial interface (75 Ohm), with 2M clock retiming function
E1B8
8-channel E1 (2MBit/s) 2mm pin interface (75 Ohm) with K20 (protection against lightning)
SE1B8
8-channel E1 (2MBit/s) 2mm pin interface (75 Ohm)
E1B28
28-channel E1 (2MBit/s) 2mm pin interface (75 Ohm) with K20 (protection against lightning)
SE1B28
28-channel E1 (2MBit/s) 2mm pin interface (75 Ohm)
DE1B8
8-channel E1 (2MBit/s) 2mm pin interface (120 Ohm) with K20 (protection against lightning)
SDE1B8
8-channel E1 (2MBit/s) 2mm pin interface (120 Ohm)
DE1JB8
8-channel E1 (2MBit/s) RJ45 interface (120 Ohm)
DE1B28
28-channel E1 (2MBit/s) 2mm pin interface (120 Ohm) with K20 (protection against lightning)
SDE1B28
28-channel E1 (2MBit/s) 2mm pin interface (120 Ohm)
SDE1B32
32-channel E1 (2MBit/s) 2mm pin interface (120 Ohm)

The E1 signals can be accessed via the E1 cables specified in Annex 2 installation cable.

ED

01
3AL 97279 ABAA TQCVA

28/48

3.5.1 2MBit/s interface connection of E1RCB8 board


The panel structure and connection mode of E1RCB8 are shown in Figure 24.
Suggested the cable of COAX. 75ohm (ref 1, Annex 3 suggested cabling)

(3)

(1)

(2)

Figure 24 - E1 signal connection of E1RCB8 board

(1) 8 x 2MBit/s service signal interfaces:


The upper row labeled TX contains the output of every 2Mbit/s channel. Each output channel can
be configured through the network management to provide a retimed 2Mbit/s service signal. The
lower row labeled RX contains the input of every 2Mbit/s channel that can be connected with the
2Mbit/s service signals of the exchange or access equipments.
(2) 2MBit/s extended signal interface:
The connector labeled with TX is the output side, the one labeled with RX is the input side. The
interface provides a channel for transmitting QECC (network management) through 2Mbit/s
signals. There are two connection modes for this channel: I) connecting to the 2Mbit/s extended
signal interface of another 1642 Edge Multiplexers E1RCB8 board through coaxial cable. II)
connecting directly to 2Mbit/s service port through coaxial cable, i.e. to map the 2Mbit/s extended
signal into the service signal and then connect through optical fiber with another transmission
equipment. The signal should be terminated on another remote 1642 Edge Multiplexer equipment
configured with the E1RCB8 board, as shown in Figure 255 on page 309.
(3) 2MBit/s clock input:
The input of the first 2Mbit/s port can be used to receive a 2MBit/s timing signal with data. The
input of the extended signal port can be used to receive a 2MHz timing signal without data.

ED

01
3AL 97279 ABAA TQCVA

29/48

Optical fiber
Mode II

Optical fiber

Mode I
Mode I

Mode II

Mode I

Figure 25 - 2Mbit/s extended signal connection

ED

01
3AL 97279 ABAA TQCVA

30/48

3.5.2 2MBit/s interface connection of E1B28 and SE1B28 boards

The E1B28 and SE1B28 boards have the following panel structure and interface layout (see Figure 26).
Suggested the cable of 75ohm (ref 4-8, Annex2 installation cable).

9 10 11 12

D
C
B
A

Pin definitions of E1B28 and SE1B28 (75) interface


Pin
1
2
3
4
5
6
7
8
9
10
11
12

A
Not used
Not used
I1
I2
I3
I4
I5
I6
I7
Not used
Not used
Not used

B
Not used
Not used
GND-I1
GND-I2
GND-I3
GND-I4
GND-I5
GND-I6
GND-I7
Not used
Not used
Not used

C
Not used
Not used
O1
O2
O3
O4
O5
O6
O7
Not used
Not used
Not used

D
Not used
Not used
GND-O1
GND-O2
GND-O3
GND-O4
GND-O5
GND-O6
GND-O7
Not used
Not used
Not used

Note: In the above tables and figures, I indicates input, O indicates output, P indicates the positive pole
of the signal and N indicates the negative pole of the signal. Gnd indicates shielded ground. For
example, I1 indicates the input signal of the first channel; GND-I1 indicates the input signal shielded
ground of the first channel; P-I1 indicates the positive pole of the input signal of the first channel and NI1 indicates the negative pole of the input signal of the first channel.

Figure 26 - 2Mbit/s interface definition of E1B28 and SE1B28 boards

ED

01
3AL 97279 ABAA TQCVA

31/48

3.5.3 2MBit/s interface connection of E1B8 and SE1B8 boards

The E1B8 and SE1B8 boards have the following panel structure and interface layout (see Figure 27).
Suggested the cable of 75ohm (ref 4-8, Annex2 installation cable)

9 10 11 12

D
C
B
A

Pin definitions of E1B8 and SE1B8 (75)


Pin
1
2
3
4
5
6
7
8
9
10
11
12

A
Not used
Not used
I1
I2
I3
I4
I5
I6
I7
I8
Not used
Not used

B
Not used
Not used
GND-I1
GND-I2
GND-I3
GND-I4
GND-I5
GND-I6
GND-I7
GND-I8
Not used
Not used

C
Not used
Not used
O1
O2
O3
O4
O5
O6
O7
O8
Not used
Not used

D
Not used
Not used
GND-O1
GND-O2
GND-O3
GND-O4
GND-O5
GND-O6
GND-O7
GND-O8
Not used
Not used

Note: In the above tables and figures, I indicates input, O indicates output, P indicates the positive pole
of the signal and N indicates the negative pole of the signal. Gnd indicates shielded ground. For
example, I1 indicates the input signal of the first channel; GND-I1 indicates the input signal shielded
ground of the first channel; P-I1 indicates the positive pole of the input signal of the first channel and NI1 indicates the negative pole of the input signal of the first channel.

Figure 27 - 2Mbit/s interface definition of E1B8 and SE1B8 boards

ED

01
3AL 97279 ABAA TQCVA

32/48

3.5.4 2MBit/s interface connection of DE1B28 and SDE1B28 boards

The DE1B28 and SDE1B28 boards have the following panel structure and interface layout (see Figure
28). Suggested the cable of 120ohm (ref 9-13, Annex2 installation cable)

9 10 11 12

D
C
B
A

Pin definitions of DE1B28 and SDE1B28 (120)


Pin
1
2
3
4
5
6
7
8
9
10
11
12

A
Not used
Not used
P-I1
P-I2
P-I3
P-I4
P-I5
P-I6
P-I7
Not used
Not used
Not used

B
Not used
Not used
N-I1
N-I2
N-I3
N-I4
N-I5
N-I6
N-I7
Not used
Not used
Not used

C
Not used
Not used
P-O1
P-O2
P-O3
P-O4
P-O5
P-O6
P-O7
Not used
Not used
Not used

D
Not used
Not used
N-O1
N-O2
N-O3
N-O4
N-O5
N-O6
N-O7
Not used
Not used
Not used

Note: In the above tables and figures, I indicates input, O indicates output, P indicates the positive pole
of the signal and N indicates the negative pole of the signal. Gnd indicates shielded ground. For
example, I1 indicates the input signal of the first channel; GND-I1 indicates the input signal shielded
ground of the first channel; P-I1 indicates the positive pole of the input signal of the first channel and NI1 indicates the negative pole of the input signal of the first channel.

Figure 28 - 2Mbit/s interface definition of DE1B28 and SDE1B28 boards

ED

01
3AL 97279 ABAA TQCVA

33/48

3.5.5 2MBit/s interface connection of DE1B8 and SDE1B8 panels

The DE1B8 and SDE1B8 boards have the following panel structure and interface layout (see Figure 29).
Suggested the cable of 120ohm (ref 9-13, Annex2 installation cable)

9 10 11 12

D
C
B
A

Pin definitions of DE1B8 and SDE1B8 (120)


Pin
1
2
3
4
5
6
7
8
9
10
11
12

A
Not used
Not used
P-I1
P-I2
P-I3
P-I4
P-I5
P-I6
P-I7
P-I8
Not used
Not used

B
Not used
Not used
N-I1
N-I2
N-I3
N-I4
N-I5
N-I6
N-I7
N-I8
Not used
Not used

C
Not used
Not used
P-O1
P-O2
P-O3
P-O4
P-O5
P-O6
P-O7
P-O8
Not used
Not used

D
Not used
Not used
N-O1
N-O2
N-O3
N-O4
N-O5
N-O6
N-O7
N-O8
Not used
Not used

Note: In the above tables and figures, I indicates input, O indicates output, P indicates the positive pole
of the signal and N indicates the negative pole of the signal. Gnd indicates shielded ground. For
example, I1 indicates the input signal of the first channel; GND-I1 indicates the input signal shielded
ground of the first channel; P-I1 indicates the positive pole of the input signal of the first channel and NI1 indicates the negative pole of the input signal of the first channel.

Figure 29 - 2Mbit/s interface definition of DE1B8 and SDE1B8 boards

ED

01
3AL 97279 ABAA TQCVA

34/48

3.5.6 2MBit/s interface connection of DE1JB8 and panels

The DE1JB8 boards have the following panel structure and interface layout .
The physical interfaces are standard RJ45 as shown in Figure 30. Customer could specify the installation
cable.

Pin definitions of DE1JB8 and (120)

Figure 30 - 2Mbit/s interface definition of DE1JB8 boards

ED

01
3AL 97279 ABAA TQCVA

35/48

3.5.7 2MBit/s interface connection of DE1B32 boards

The DE1B32 board have the following panel structure and interface layout (see Figure 31).
Suggested the cable of 120ohm (ref 9-13, Annex2 installation cable)

9 10 11 12

D
C
B
A

Pin definitions of DE1B32 (120)


Pin
1
2
3
4
5
6
7
8
9
10
11
12

A
Not used
Not used
P-I1
P-I2
P-I3
P-I4
P-I5
P-I6
P-I7
P-I8
Not used
Not used

B
Not used
Not used
N-I1
N-I2
N-I3
N-I4
N-I5
N-I6
N-I7
N-I8
Not used
Not used

C
Not used
Not used
P-O1
P-O2
P-O3
P-O4
P-O5
P-O6
P-O7
P-O8
Not used
Not used

D
Not used
Not used
N-O1
N-O2
N-O3
N-O4
N-O5
N-O6
N-O7
N-O8
Not used
Not used

Note: In the above tables and figures, I indicates input, O indicates output, P indicates the positive pole
of the signal and N indicates the negative pole of the signal. Gnd indicates shielded ground. For
example, I1 indicates the input signal of the first channel; GND-I1 indicates the input signal shielded
ground of the first channel; P-I1 indicates the positive pole of the input signal of the first channel and NI1 indicates the negative pole of the input signal of the first channel.

Figure 31 - 2Mbit/s interface definition of DE1B32 board

ED

01
3AL 97279 ABAA TQCVA

36/48

3.6 34MBit/s and 45MBit/s tributary connections


The E3 and DS3 tributary boards provide 34MBit/s and 45MBit/s interfaces respectively. Both use 75
coaxial connectors (1.0/2.3) and have the same panel structure and connection mode, as shown in Figure
32. The E3 and DS3 signals use the suggested cable of COAX. 75ohm (ref 2, Annex 3 suggested cabling)

(1)

(2) (3)

(1)

(2) (3)

(1) Panel LED


(4) 75Ohm (1.0/2.3) coaxial interface output
(5) 75Ohm (1.0/2.3) coaxial interface input

Figure 32 - 34Mbit/s and 45Mbit/s interfaces connection

ED

01
3AL 97279 ABAA TQCVA

37/48

3.7 Ethernet interface connection


3.7.1 Ethernet electrical interface
All Ethernet/Fast Ethernet tributary board provides 10/100 Base-T interface. The physical interfaces are
RJ45 and standard UTP-5 wire, as shown in Figure 33. The Ethernet signals can be accessed via cross
Ethernet cables (ref 23-24, Annex2 installation cable)

8 76 54321

RJ45 Pin definitions

Signal
name
RXP

RXN

TXP

TXN

4, 5, 7, 8

NC

Pin

Signal
description
Receiving data
differential pair
(from cable)
N-I2
Transmitting
data differential
pair (to cable)
Not used

Description

Cat 5 UTP/STP

Figure 33 - Ethernet electrical interface connection

ED

01
3AL 97279 ABAA TQCVA

38/48

3.7.2 Ethernet optical interface


For ISA-ES1 3FE board,it use Small Form Pluggable (SFP) module for Ethernet optical interface,its type is
LC. The user can purchase and install it according your application. Connect as shown in Figure 34. It is
suggested to use SC/PC--LC tail fiber.
Note: The SFP module removing needs dedicate removing tools(ref 13, annex1).
Alarm

SFP

2*RJ45

TX RX

LC optical fiber connectors, RX = receiving side


LC optical fiber connectors, TX = transmitting side

Figure 34 - Ethernet optical interface connection

ED

01
3AL 97279 ABAA TQCVA

39/48

3.8 2048Kbit/s, 75 Ohm clock connection


1642 Edge Multiplexer provides one input and one output 2Mbit/s channel for synchronization. It is an
unbalanced 75ohm coaxial 1.0/2.3 interface. The interface connectors are located on the main board,
marked as 2MI and 2MO, as shown in Figure 35. The cables to be used the suggested cable of COAX.
75ohm (ref 1, Annex 3 suggested cabling)

Figure 35 - 2Mbit/s, 75 Ohm clock interface connection

ED

01
3AL 97279 ABAA TQCVA

40/48

3.9 Auxiliary data and houseKeeping connections on Main Board


1642 Edge Multiplexer provides 4 user channels for auxiliary data on the Main Board. They can be accessed
through the DB25 interface on the Main Boards front panel. It also provide housekeeping interface.They can
be used for providing external environment monitor, alarm and access control, etc.The connection of the
auxiliary is shown in Figure 36.
The overhead bytes E2, F1, SI and SO connection can be made use cable (ref 8, Annex3 suggested
cabling). One end of the cable is a DB25 male connector. The other end can be a DB9 female connector or
as user like.
Definition of E2, F1 auxiliary data cables
Port 1
F1
Signal
Name
F1TXD
F1RXD
GND
E2
Signal
Name
E2TXD
E2RXD
GND

DB-25
Connector
Pin
21
20
22
DB-25
Connector
Pin
24
23
25

Port 2
F1
Signal
Name
F1TXD
F1RXD
GND
E2
Signal
Name
E2TXD
E2RXD
GND

DB-25
Connector
Pin
15
14
16
DB-25
Connector
Pin
18
17
19

Definition of SI cables
input
DB-25
House
Connector
keeping
pin
Signal
name
Input[1]+
12
Input[1]11
Input[2]+
10
Input[2]9
Input[3]+
8
Input[3]7

DB9
(Female)
3
2
5
DB9
(Female)
3
2
5
DB9
(Female)
3
2
5
DB9
(Female)
3
2
5

Definition of SO cables
output
DB-25
House
Connector
keeping
pin
Signal
name
Output[1]+
6
Output[1]5
Output[2]+
4
Output[2]3
Output[3]+
2
Output[3]1

Figure 36 - Auxiliary Data and HouseKeeping connections on MB

ED

01
3AL 97279 ABAA TQCVA

41/48

3.10 Debug interface connection


Debug interface is the six one of the eight adjacent RJ11 interfaces on the main board panel, marked as
DBGL and its connection is shown in Figure 37. The suggested cable is 3AL97089A* (annex 2 installation
cables).
N.B.

This interface is only supplied for field engineer of commissioning or test engineer in manufactory.

1
DBG_L
Signal name

RJ11
pin

DB9
pin

RXD
TXD
DTR
GND

3
2
4
5

2
3
4
5

RJ11 male connector


(Pins are at the top)

Figure 37 - Connection of DBGL interface

ED

01
3AL 97279 ABAA TQCVA

42/48

3.11 Q interface connection


Q interface is the RJ45 interfaces on the main board panel, marked as Q and its connection is shown in
Figure 38. Suggested the cable of management connected with PC (ref 23-24, Annex2 installation cable)
N.B.

This interface is only supplied for field engineer of commissioning or test engineer in manufactory.

Q
1
RJ45 Pin definitions

Signal
name
TXP

TXN

RXP

RXN

4, 5, 7, 8

NC

Pin

Signal
description
Transmitting
data differential
pair (to cable)
Receiving data
differential pair
(from cable)
N-I2
Not used

cabl
e

Cat 5
UTP

Figure 38 - Connection of Q interface

ED

01
3AL 97279 ABAA TQCVA

43/48

3.12 OW Interface

3.12.1

Assembly and disassembly the EOW board

EOW module is an optional configuration, It could been fixed on the main board separately, show as Figure
39.
Assembly:
Install EOW module(2) with two spacer supports(1) on the main board. Ensure the nether clips of
spacer supports pass through the two holes on the main board, the corresponding connectors on main board
and EOW module are connected tightly. make sure EOW module and main board contacted well,
Disassembly:
Disconnect EOW module from the lower clips of spacer supports carefully.
Lift EOW module.

Figure 39 - Assembly and disassembly the EOW board

ED

01
3AL 97279 ABAA TQCVA

44/48

3.12.2 OW Interface connection


OW interface is a phone jack on the main board panel, marked as OW, connect with Order Wire phone set.
Labled as OW, show as Figure 40 . The cables to be used are specified in Annex1 Parts making up the
Installation set, ref 12.

Figure 40 - Connection of OW interface

ED

01
3AL 97279 ABAA TQCVA

45/48

ANNEXES

4.1 Annex 1. - Parts making up the Installation set


Ref

NAME

1642EMUX INSTALLATION KIT PACKAGE MADE UP OF


1
Kit Installation 21(for horizontal)
1.1
21 Adapter
1.2
Stainless Screw M4*6
1.3
Stainless Screw M6*16
1.4
Plastic Washer 6
1.5
Square Nut M6
Kit Installation 19
2
2.1
19 Adapter
2.2
Stainless Screw M4*6
2.3
Stainless Screw M6*16
2.4
Plastic Washer 6
2.5
Square Nut M6
3
Kit Installation Wall
3.1
Adapter Wall
3.2
Stainless Screw M3*8
3.3
Expansion Bolt M6
3.4
Washer Locker6
3.5
Plastic Washer 6
3.6
Hex Nut M6
4
Kit Installation 21(for 300mm deep angle)
4.1
Left Angle adapter
4.2
Right Angle adapter
4.3
Stainless Screw M4*6
4.4
Stainless Screw M6*16
4.5
Plastic Washer 6
4.6
Square Nut M6
5
Kit Installation cable support
5.1
Square Nut M6
5.2
Stainless Screw M6*16
5.3
Cable support
6
EOW module package
6.1
Spacer supports
6.2
EOW module
1642EMUX ELECTRICAL SIGNALS CONNECTORS
7
1.0-2.3 75ohm COAX CONN.(3MM)
8
1.0-2.3 75ohm COAX CONN.(4.4MM)
9
RJ45 8P CONNECTOR
10
HM 2MM 4*8 CONNECTOR ASSEMBLY
1642EMUX MISCELLANEOUS
11
DUMMY PLATE
12
Alcatel OW phone (with attachment)
13
Dedicated SFP removing tool

ED

PART No.

MAX.QTY

3AL97127AAAA
3AL 97102 AAAA
N/A
GB819-86
GB818-86
GB/T 848
N/A
3AL 97102 ABAA
N/A
GB819-86
GB818-86
GB/T 848
N/A
3AL 97102 ACAA
N/A
GB6074
N/A
GB93-87
GB/T 848
GB6170-86
3AL 97142 AAAA
N/A
N/A
GB819-86
GB818-86
GB/T 848
N/A
3AL97169 AAAA
N/A
GB818-86
N/A
3AL97161 AAAA
1AD048740001
3AL97161AAAA

1
2
4
4
4
4
1
2
4
4
4
4
1
2
4
4
4
4
4
1
1
1
4
4
4
4
1
4
4
1
1
2
1

1AB061220003
1AB061220008
1AB074610008
85348-5005

74
8
25
16

3AL97082AAAA
1AF00398AAZE
3AL81424AAAA

4
1
1

01
3AL 97279 ABAA TQCVA

46/48

4.2 Annex 2. - Installation Cables


Ref
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

NAME
CA-Power supply AC220V
CA-F interface Cable
CA-Terminal Cable
CA-HM 2MM 8*2M*75ohm*5M
CA-HM 2MM 8*2M*75ohm*10M
CA-HM 2MM 8*2M*75ohm*20M
CA-HM 2MM 8*2M*75ohm*30M
CA-HM 2MM 8*2M*75ohm*40M
CA-HM 2MM 8*2M*120ohm*5M
CA-HM 2MM 8*2M*120ohm*10M
CA-HM 2MM 8*2M*120ohm*20M
CA-HM 2MM 8*2M*120ohm*30M
CA-HM 2MM 8*2M*120ohm*40M
CA-Power cable.DC48V.3M
CA-Power cable.DC48V.5M
CA-Power cable.DC48V.10M
CA-Power cable.DC48V.20M
CA-Power.EMC.DC48V.3M
CA-Power.EMC.DC48V.5M
CA-Power.EMC.DC48V.10M
CA-Power.EMC.DC48V.20M
Management Cable. 30MthroughRJ45RJ45
Management Cable. 30McrossRJ45RJ45
Management Cable. 5McrossRJ45RJ45

PART No.
3AL 97087 AAAA
3AL 97090 AAAA
3AL 97089 AAAA
3AL 97093 AAAA
3AL 97093 ABAA
3AL 97093 ACAA
3AL 97093 ADAA
3AL 97093 AQAA
3AL 97093 AEAA
3AL 97093 AFAA
3AL 97093 AGAA
3AL 97093 AHAA
3AL 97093 ARAA
3AL 97109 AAAA
3AL 97109 ABAA
3AL 97109 ACAA
3AL 97109 ADAA
3AL 97147 AAAA
3AL 97147 ABAA
3AL 97147 ACAA
3AL 97147 ADAA
S3520301DAAA
S3510323DAAA
S3510323AFAA

NOTES
1,6
2
2
3
3
3
3
3
4
4
4
4
4
1
1
1
1
5
5
5
5
2
2
2

NOTES:
1. Ref.1, 14~17 power supply cable all adopt the suggest cable, see Annex3 ref.6 for more details
2. Ref.2~3, 22~24 cable all adopt the suggest cable, see Annex3 ref.7 for more details
3. Ref.4~9 E1 75ohm cable all adopt the suggest cable, see Annex3 ref.3 for more details
4. Ref.10~14 E1 120ohm cable all adopt the suggest cable, see Annex3 ref.5 for more details
5. Ref.18~21 is the double shield cable of DC48V/24V power when EMC Class B qualification is
needed.
6. Ref.1 power supply cable is triangle dedicate for chinese power socket.

ED

01
3AL 97279 ABAA TQCVA

47/48

4.3 Annex 3. - Suggested cabling

REF

CABLE TYPE

CONNECTION
TYPE

COAX. cable
75 ohm (3 mm)
COAX. cable
75 ohm (4.4 mm)
8-pairs coax cable
75 ohm
7-pairs coax cable
75 ohm
8-pairs twisted pair
cable 120 ohm
power supply
cable
4-pairs shielded
(FTP or STP
4*2*24AWG)
16 pairs shielded
wire-wrap cable

2
3
4
5
6
7
8

DIA (mm) or SECT.


(mm2)

FACTORY P/N.
(NV / PN)

NOTES

1AC 00110 0013


(049.475.400 Y)
1AC 00110 0023
(049.475.403 P)
SYFE -75-1.5-1*8

SOLDER/CRIMP

INT.
0.5

EXT.
3.1 max

SOLDER/CRIMP

0.5

4.8 max

Special

0.32

8.2 max

Special

0.40

10.0 max

Special

0.40

7.5 max

SOLDER

1.5

9.2 max

Crimp0

0.5

5.1 max

FTP or STP
4*2*AWG24

Wire-Wrap

0.4

8.5 max

1AC 01487 0009


(049.720.404Z)

SYFE -75-2-1*7
(3AL 98086)
SEYEP-120
4*4*0.32
RVV 3*1.5mm2

b
c
c
c
d

NOTES :
a - terminate with supplied 75ohm coax connector 3mm(1AB 06122 0003)
b - terminate with supplied 75ohm coax connector 4.4mm(1AB 06122 0008)
c - terminate with supplied HM 2MM 4*8 CONNECTOR. (85348-5005)
d - terminate with supplied 3p SUB-D power connector
e - terminate with supplied RJ45 connectors (1AB 07461 0008) for Ethernet interface connection;
terminate with supplied 9p SUB-D (DB9) male and female connectors for F interface connection;
terminate with supplied 6p RJ11 connector and 9p SUB-D (DB9) female connector for debug
interface connection.
f - terminate with supplied 25p SUB-D (DB25) male connector set(3AL97255AAAA) on one end for
auxiliary data and houseKeeping connections

END OF DOCUMENT