Sie sind auf Seite 1von 479

ADC is now TE Connectivity

TrueNet structured cabling solutions

TrueNet

Structured Cabling Solutions

4th Edition

4th Edition

Catalog

www.te.com/adc

tE Connectivity, tE connectivity (logo), tyco Electronics, and tE (logo) are trademarks of the tE Connectivity ltd. family of companies
and its licensors.
While tE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, tEConnectivity does
not guarantee that it is error-free, nor does tE Connectivity make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. tE Connectivity reserves the right to make any adjustments to the information contained herein at
any time without notice. tE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including,
but not limited to, any implied warranties of merchantability or fitness for a particular purpose. the dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult
tEConnectivity for the latest dimensions and design specifications.

www.te.com/adc

ADC is now TE Connectivity

contact us:
P.o. Box 1101
Minneapolis, Minnesota
USa 55440-1101
tel: 1-800-366-3891
tel: 1-952-938-8080
Fax: 1-952-917-3237

ADC and Tyco Electronics


are now TE Connectivity

tyco Electronics Corporation, a tE Connectivity ltd. Company. all Rights Reserved.


102094aE8/11Revision 2011, 2008, 2006, 2005

truenet cover.indd 1

8/29/11 3:26 PM

Table of Contents

11/11

102094AE

TrueNet Structured Cabling

Introduction .......................................................................................................................................... 1
Technical Reference
Designing the Optimized Data Center .............................................................................................. 18
Industry Standards ............................................................................................................................ 23
How to Choose the Right Cabling Infrastructure .............................................................................. 36
10Gigabit Ethernet over UTP ............................................................................................................ 39
Choosing the Right Ethernet Patch Panels ........................................................................................ 43
Key Fiber Optic Cable Management Concepts.................................................................................. 48
Copper Cable Solutions
Introduction ...................................................................................................................................... 52
CopperTen Augmented Category 6 Horizontal Cable ..................................................................... 53
CopperTen Category 6a Plenum Data Cable ................................................................................ 53
CopperTen Category 6a Riser Data Cable..................................................................................... 54
CopperTen Augmented Category 6 F/UTP Horizontal Cable ............................................................. 55
CopperTen Four Pair F/UTP Plenum Cable .................................................................................... 55
CopperTen Four Pair F/UTP Riser Cable......................................................................................... 58
Category 6 Horizontal Cable ............................................................................................................. 61
Category 6 Plenum Cable ............................................................................................................ 61
Category 6 Riser Cable ................................................................................................................. 64
Category 6 Bundled Plenum Cable............................................................................................... 67
Category 6 Bundled Riser Cable ................................................................................................... 70
Category 6 Limited Combustible Cable............................................................................................. 73
Category 6 Outdoor Cable................................................................................................................ 76
Category 5e Horizontal Cable ........................................................................................................... 79
Category 5e Plenum Cable........................................................................................................... 79
Category 5e Riser Cable .............................................................................................................. 82
Category 5e Bundled Riser Cable ................................................................................................ 85
Category 5e Outdoor Cable ......................................................................................................... 88
Category 5e Backbone Cable ....................................................................................................... 90
25-Pair Category 5e Plenum Cable............................................................................................... 90
25-Pair Category 5e Riser Cable ................................................................................................... 92
Category 3 Horizontal and Backbone Cable ..................................................................................... 94
Category 3 Plenum Cable ............................................................................................................ 94
Category 3 Riser Cable ................................................................................................................. 96
Category 1 Horizontal and Backbone Cable ..................................................................................... 98
UTP Plenum Cable........................................................................................................................ 98
UTP Riser Cable .......................................................................................................................... 100
Copper Connectivity Solutions Category 6a UTP
Introduction .................................................................................................................................... 104
CopperTen UTP Horizontal Cable .................................................................................................... 105
CopperTen Category 6a Plenum Data Cable .............................................................................. 105
CopperTen Category 6a Riser Data Cable ................................................................................. 106
CopperTen UTP Patch Panels........................................................................................................... 107
CopperTen UTP Termination Blocks ................................................................................................. 109
CopperTen Augmented Category 6 8-Pair Block ........................................................................ 110
CopperTen UTP Modular Jack ......................................................................................................... 112

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Table of Contents

TrueNet Structured Cabling


102094AE

11/11

Table of Contents

CopperTen UTP Patch Cords .............................................................................................................. 113


Augmented Category 6 Patch Cords
For CopperTen 8-Pair and 20-Pair Termination Blocks ............................................................... 114
CopperTen UTP Faceplate ............................................................................................................... 116
CopperTen UTP Surface Mount Box ................................................................................................ 117
Copper Connectivity Solutions Category 6a F/UTP
Introduction .................................................................................................................................... 120
CopperTen F/UTP Horizontal Cable ................................................................................................. 121
CopperTen Four-Pair F/UTP Plenum Cable .................................................................................. 121
CopperTen Four-Pair F/UTP Riser Cable ....................................................................................... 125
CopperTen F/UTP Patch Panels ........................................................................................................ 129
CopperTen F/UTP Modular Jack....................................................................................................... 130
CopperTen F/UTP Patch Cords ......................................................................................................... 131
Copper Connectivity Solutions Category 6
Introduction .................................................................................................................................... 134
Category 6 Copper Cable ............................................................................................................... 135
Category 6 Plenum Cable .......................................................................................................... 135
Category 6 Riser Cable ............................................................................................................... 138
Category 6 Bundled Plenum Cable............................................................................................. 141
Category 6 Pair Outdoor Cable .................................................................................................. 144
Patch Panels .................................................................................................................................... 147
TrueNet Patch Panels ................................................................................................................ 147
24-Port ................................................................................................................................... 147
48-Port ................................................................................................................................... 147
Dynamic Angle Right/Left Patch Panels ...................................................................................... 149
UMS/Mini Patch Panels............................................................................................................... 150
Plug-and-Play Patch Panels ......................................................................................................... 151
Patch Plus 24-Port .................................................................................................................. 151
48-Port High Density .............................................................................................................. 151
24-Port High Density .............................................................................................................. 151
12-Port Mini ........................................................................................................................... 151
Termination Blocks .......................................................................................................................... 153
Ultim8 Termination Blocks ........................................................................................................ 153
Ultim8 Field Assembly Kits.......................................................................................................... 154
HighBand 25 Termination Blocks .............................................................................................. 155
300-Pair Basic System ............................................................................................................. 156
900-Pair Basic System ............................................................................................................. 156
300-Pair Cable Management Kit ............................................................................................ 156
900-Pair Cable Management Kit ............................................................................................ 156
HighBand 25 Block with Rear Cable Manager........................................................................ 156
HighBand 25 25-Pair Voice Module........................................................................................ 156
Modular Jacks ................................................................................................................................. 158
Patch Cords..................................................................................................................................... 159
Patch Cords for Ultim8 Blocks .................................................................................................... 160
Ultim8 1- and 2-Pair Patch Cords ............................................................................................... 161
HighBand 25 Patch Cords .......................................................................................................... 162
Category 6 Specialty Patch Cords ............................................................................................... 163

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11/11

102094AE

TrueNet Structured Cabling

Table of Contents
Copper Connectivity Solutions Category 5e
Introduction .................................................................................................................................... 166
Category 5e Copper Cable ............................................................................................................. 168
Category 5e Plenum Cable......................................................................................................... 168
Category 5e Riser Cable ............................................................................................................ 171
Category 5e Bundled Riser Cable ............................................................................................... 174
Category 5e The Outback Outdoor Cable ................................................................................ 177
Patch Panels .................................................................................................................................... 180
TrueNet Patch Panels ................................................................................................................ 180
24-Port ................................................................................................................................... 180
48-Port ................................................................................................................................... 180
Dynamic Angle Right/Left Patch Panels ...................................................................................... 181
Plug-and-Play Patch Panels ......................................................................................................... 182
Patch Plus 24-Port, ................................................................................................................. 182
12-Port Mini Patch Panel ........................................................................................................ 182
UMS/Mini Patch Panels............................................................................................................... 183
Modular Jacks ................................................................................................................................. 184
Patch Cords..................................................................................................................................... 185
Category 5e Specialty Patch Cords ............................................................................................. 186
Copper Connectivity Solutions Specialty Products
Ethernet Test Access Panel .............................................................................................................. 190
T1 Demarcation Modular Patch Panels............................................................................................ 191
RJ45 Coupler Panel ......................................................................................................................... 192
Fast Ethernet Patch Panels .............................................................................................................. 193
25-Pair Cable Assemblies ................................................................................................................ 194
RJ21x/RJ21x................................................................................................................................ 194
RJ21x/Hydra ............................................................................................................................... 194
Highband 10 Collocation Block Systems ....................................................................................... 195
100-Pair...................................................................................................................................... 195
200-Pair...................................................................................................................................... 195
300-Pair...................................................................................................................................... 195
Feed-Thru (FT) Termination Block Systems ....................................................................................... 197
5-Pair Color-Coded..................................................................................................................... 198
4-Pair Color-Coded..................................................................................................................... 198
Type 160 Hinged Label Holder ................................................................................................... 198
Label Sheets for Type 160 Hinged Label Holder ........................................................................ 198
Feed-Thru (FT) Field Assembly Kits .................................................................................................. 199
100-Pair, 4-Pair Color-Coded Kit................................................................................................. 200
100-Pair, 5-Pair Color-Coded Kit................................................................................................. 200
300-Pair, 4-Pair Color-Coded Kit................................................................................................. 200
300-Pair, 5-Pair Color-Coded Kit................................................................................................. 200
Patch Cords for Feed-Thru (FT) Blocks ............................................................................................. 201
4-Pair FT Plug to RJ45 (8P8C) Plug ............................................................................................. 202
1-Pair FT Plug to FT Plug............................................................................................................. 202
2-Pair FT Plug to FT Plug............................................................................................................. 202
Feed-Thru (FT) Block Test Shoe Harness .......................................................................................... 203
Feed-Thru (FT) Block Test Cord ........................................................................................................ 203

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling


102094AE

Copper Cable Management Solutions


Ethernet Distribution Frame ............................................................................................................ 206
Vertical and Horizontal Cable Management.................................................................................... 207
Glide Cable Manager ................................................................................................................. 207
Finger Duct Front Managers ....................................................................................................... 210
Finger Duct Front and Rear Managers ........................................................................................ 210
Vertical Cable Manager for 7 Equipment Racks......................................................................... 211
Termination Block Mounting Hardware ........................................................................................... 212
Introduction................................................................................................................................ 212
Universal Mounting System ........................................................................................................ 213
Universal Mounting System (UMS) Cable and Wire Managers ................................................... 214
Universal Mounting System (UMS) Backboards .......................................................................... 216
Universal Mounting System (UMS) High Volume Cable Managers ............................................. 217
Back Mount Frames ........................................................................................................................ 218
Type 85 Back Mount Frames ...................................................................................................... 218
Type 105 Back Mount Frames .................................................................................................... 219
Type 105 Back Mount Frames with Ground Lug ........................................................................ 220
Rod Mount Frames ......................................................................................................................... 221
Type 85 Rod Mount Brackets ..................................................................................................... 221
Type 105 Rod Mount Brackets ................................................................................................... 222
Rod Mount Bracket Spacer......................................................................................................... 222
Rod Mount Bracket Spacer......................................................................................................... 222
Mounting Frames............................................................................................................................ 223
19 Mounting Frame ................................................................................................................ 223
23 Mounting Frame ................................................................................................................ 223
35.5 Mounting Frame .............................................................................................................. 223
Wall or Rack Mount Support Bars ................................................................................................... 224
19 Support Bar ......................................................................................................................... 224
23 Support Bar ......................................................................................................................... 224
35.5 Support Bar...................................................................................................................... 224
Type 85 and Type 105 Inverted Support Bars ............................................................................. 225
Jumper Ring Bars ............................................................................................................................ 226
19 Jumper Ring Bars ............................................................................................................... 226
23 Jumper Ring Bars ............................................................................................................... 226
35.5 Jumper Ring Bars ............................................................................................................. 226
Accessories...................................................................................................................................... 227
Vertical Cable Organizer ............................................................................................................ 227
High-Density Cable Manager ..................................................................................................... 227
Horizontal Cable Organizer ........................................................................................................ 227
High-Density Cable Manager ..................................................................................................... 227
Rear Wire Management Guide................................................................................................... 227
Ring Wire Manager .................................................................................................................... 227

11/11

Table of Contents

Table of Contents

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11/11

102094AE

TrueNet Structured Cabling

Table of Contents
Copper Connectivity Solutions Accessories and Labels
Accessories...................................................................................................................................... 230
HighBand to Series 2 Adapter .................................................................................................. 230
HighBand Dummy Plug .............................................................................................................. 230
HighBand Marking Cap .............................................................................................................. 230
HighBand Bridging Test Cord ..................................................................................................... 230
HighBand Look-Both-Ways Test Cord ..................................................................................... 230
HighBand Winged West Adapter ............................................................................................... 230
HighBand Disconnect Plug ......................................................................................................... 230
Labeling .......................................................................................................................................... 231
Type 105 Label Strip ................................................................................................................... 231
Type 105 Label Holder ................................................................................................................ 231
Type 105 Hinged Label Holder ................................................................................................... 232
Side-Mount Label Holder............................................................................................................ 232
Paper Labels ............................................................................................................................... 233
Copper and Fiber Labeling Software and Labeling Sheets .......................................................... 235
Work Area Solutions
Introduction .................................................................................................................................... 240
Category 6a Modular Jacks ............................................................................................................. 241
Category 6 Modular Jacks............................................................................................................... 242
Category 5e Modular Jacks ............................................................................................................. 243
Modular Adapters ........................................................................................................................... 244
F-81 Adapter .............................................................................................................................. 245
SC Multimode/Singlemode Adapter ........................................................................................... 245
ST Multimode/Singlemode Adapter .......................................................................................... 245
LC Multimode/Singlemode Adapter ........................................................................................... 245
BNC Adapter .............................................................................................................................. 245
S-Video Adapter ......................................................................................................................... 245
RCA Adapter .............................................................................................................................. 245
Blank Modular Insert .................................................................................................................. 245
Angled Port Faceplates.................................................................................................................... 246
4-Port ......................................................................................................................................... 246
8-Port ......................................................................................................................................... 246
Extender ..................................................................................................................................... 246
Flush Mount Faceplates................................................................................................................... 247
Single-Gang
2-Port ..................................................................................................................................... 248
4-Port ..................................................................................................................................... 248
CopperTen 4-Port Staggered Faceplate ................................................................................. 248
6-Port Faceplate ..................................................................................................................... 248
Dual-Gang
4-Port Faceplate ..................................................................................................................... 248
8-Port Faceplate ..................................................................................................................... 248
12-Port Faceplate ................................................................................................................... 248

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling


102094AE

11/11

Table of Contents

Table of Contents
Specialty Faceplates......................................................................................................................... 249
Stainless Steel Faceplate ............................................................................................................. 250
Stainless Steel Wall Phone Plate ................................................................................................. 250
4-Port Walker Monument Faceplate ........................................................................................... 250
Drywall Faceplate Adapter.......................................................................................................... 250
Electrical Faceplate 106 Adapters ............................................................................................... 250
2-Port ......................................................................................................................................... 250
4-Port ......................................................................................................................................... 250
Dual-Gang Surface Mount Box .................................................................................................. 250
Modular Furniture Faceplates .......................................................................................................... 251
CopperTen 3-Port ....................................................................................................................... 252
3-Port ......................................................................................................................................... 252
4-Port ......................................................................................................................................... 252
4-Port Beltline Adapter ............................................................................................................... 252
2-Port ......................................................................................................................................... 252
Surface Mount Boxes ...................................................................................................................... 253
2-Port ......................................................................................................................................... 253
4-Port ......................................................................................................................................... 253
6-Port ......................................................................................................................................... 253
CopperTen 6-Port ..................................................................................................................... 253
Surface Box for Modular Furniture .................................................................................................. 254
12-Port ....................................................................................................................................... 254
Mounting Accessories ................................................................................................................ 254
Specialty Boxes................................................................................................................................ 255
Multimedia Box .......................................................................................................................... 255
Empty Multimedia Bezels ........................................................................................................... 255
All-Fit Specialty Box
6-Port ..................................................................................................................................... 256
4-Port ..................................................................................................................................... 256
Steel Cover ............................................................................................................................. 256
Duplex SC Bezel ..................................................................................................................... 256
All-Fit Surface Mount Box....................................................................................................... 256
Magnet Strip .......................................................................................................................... 256
Accessories...................................................................................................................................... 258
Termination Puck ........................................................................................................................ 258
ID Tabs with Icons Numbered 16 .............................................................................................. 258
Paper Labels for Faceplates......................................................................................................... 258
Data Center Optical Distribution Frame Solutions
Introduction .................................................................................................................................... 259
Fiber Main Distribution Frame ......................................................................................................... 262
Frame Accessories ...................................................................................................................... 263
Fiber Optic Terminal Jumper Storage Panel................................................................................. 263
End Guard .................................................................................................................................. 264
Fiber Termination Blocks (FTBs)........................................................................................................ 265

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11/11

102094AE

TrueNet Structured Cabling

Table of Contents
Fiber Termination Blocks (FTBs) Factory Terminated Stubs ........................................................ 265
SC Style FTBs with Factory Terminated Stubs .......................................................................... 266
LC Style FTBs with Factory Terminated Stubs .......................................................................... 266
Fiber Termination Blocks (FTBs) Unterminated (Adapter Only) ................................................. 268
Cable Clamping/Block Conversion Kits ....................................................................................... 271
Sliding Adapter Packs...................................................................................................................... 272
Data Center Splice Cabinet ............................................................................................................. 273
Accessories...................................................................................................................................... 274
Splice Wheel............................................................................................................................... 274
Cable Clamps ............................................................................................................................. 274
Cable Clamp Kit ......................................................................................................................... 275
Frame Installation Kit .................................................................................................................. 276
Fiber Connectivity Solutions
Introduction .................................................................................................................................... 278
TFP System ...................................................................................................................................... 280
Introduction................................................................................................................................ 280
Product Overview ....................................................................................................................... 281
Panel Configurations .................................................................................................................. 282
Chassis Dimensions .................................................................................................................... 283
TFP Series Empty Chassis ............................................................................................................ 285
TFP Series Standard Adapter Packs ............................................................................................. 286
TFP Series Standard Adapter Packs with Pigtails ......................................................................... 287
TFP Series Custom Adapter Packs............................................................................................... 288
Pre-Configured TFP Series Custom Termination/Splice Fiber Panels............................................. 289
Fiber Management Tray .................................................................................................................. 290
Introduction................................................................................................................................ 290
Product Overview ............................................................................................................................ 292
1 Rack Unit Specifications ............................................................................................................... 293
1 Rack Unit Slack Storage .......................................................................................................... 294
1 RU Adapter-Only Fiber Termination Drawers ........................................................................... 295
1 Rack Unit Termination / Splice Drawer with Adapters and Pigtails........................................... 296
2 Rack Unit Termination with Adapters Only .............................................................................. 297
2 Rack Unit Termination and Splice ............................................................................................ 298
1 Rack Unit Mini Splice Tray ....................................................................................................... 299
1 Rack Unit Wall Mount Kit, Cable Clamp Kit and Vertical Cable Guide .................................... 299
2 Rack Unit Mini Splice Tray ....................................................................................................... 300
2 Rack Unit Cable Clamp Kit and Vertical Cable Guide .............................................................. 300
FL2000 System ................................................................................................................................ 301
Product Overview ....................................................................................................................... 302
Empty Termination/Splice Panels................................................................................................. 303
Empty Termination Panels........................................................................................................... 304
Empty Splice Panels .................................................................................................................... 305
6pak Connector Plug-Ins ............................................................................................................ 306
6pak Connector Plug-Ins with Adapters and Pigtails .................................................................. 307
Preconfigured Termination/Splice Panels ..................................................................................... 308
Custom Preconfigured Termination/Splice Panels with
Two Adapter Styles..................................................................................................................... 309

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling


102094AE

11/11

Table of Contents

Table of Contents
Mounting Options ...................................................................................................................... 310
19 (48.26cm) Rack Mounting: Standard and Flush Mount ................................................... 310
19 (48.26cm) Rack Maximum Mounting .............................................................................. 311
RMG Series Fiber Enclosures ........................................................................................................... 312
Product Overview ....................................................................................................................... 313
Specifications ............................................................................................................................. 314
RMG Empty Panels ..................................................................................................................... 316
RMG Standard Adapter Packs .................................................................................................... 317
Custom Modular Adapter Packs................................................................................................. 318
RMG Pre-Configured Panels with Adapters Only or with Pigtails................................................ 319
FL1000 System ................................................................................................................................ 320
Introduction................................................................................................................................ 320
Product Overview ....................................................................................................................... 320
Wall Mount Boxes ...................................................................................................................... 320
One Door Wall Mount Chassis ................................................................................................... 321
Two Door Wall Mount Chassis ................................................................................................... 323
6pak Connector Plug-Ins and Accessories .................................................................................. 324
6pak Adapter Adapters and Pigtails ...................................................................................... 325
WMG Series Wall Mount Enclosures ............................................................................................... 326
Product Overview ....................................................................................................................... 326
WMG Empty Wall Box................................................................................................................ 327
Modular Adapter Packs .............................................................................................................. 328
WMG Standard Adapter Packs ................................................................................................... 329
Custom Modular Adapter Packs................................................................................................. 330
Fiber Optic Specifications ................................................................................................................ 331
Optical Performance ................................................................................................................... 331
Mechanical and Environmental Characteristics ........................................................................... 331
Patch Cords ................................................................................................................................ 332
Connector Dimensions ............................................................................................................... 332
Fiber Optic Patch Cords................................................................................................................... 333
Fiber Optic Connectors ................................................................................................................... 335
Accessories ................................................................................................................................. 337
Field Termination Kit ............................................................................................................... 337
Field Termination Consumables Kit ......................................................................................... 338
Fiber Connector/Adapter Cleaning Kit .................................................................................... 339
Field Installation Connectors................................................................................................... 340
Field Installation Tool Kit ......................................................................................................... 341
Fiber Plug-and-Play Solutions
Introduction .................................................................................................................................... 344
Polarity Made Simple ...................................................................................................................... 345
Data Center Optical Distribution Frame with Plug-and-Play Cassettes............................................. 346
TFP Plug-and-Play Cassettes ............................................................................................................ 349
TFP MPO Pack ................................................................................................................................. 352
RMG Plug-and-Play Cassettes ......................................................................................................... 353
Plug-and-Play Microcable Trunk Assemblies .................................................................................... 355
High Fiber Count Plug-and-Play Trunks ........................................................................................... 358
12 Fiber Plug-and-Play Array Cables................................................................................................ 361
MPO Cleaning Kit ........................................................................................................................... 364

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11/11

102094AE

TrueNet Structured Cabling

Table of Contents
Fiber Cable Raceway Systems
Introduction .................................................................................................................................... 366
Features and Benefits ...................................................................................................................... 367
Recommended and Maximum Patch Cord Densities ....................................................................... 368
FiberGuide Fiber Management System .......................................................................................... 369
Express Exits Units .................................................................................................................... 369
2x2 System ................................................................................................................................. 369
2x6 System ................................................................................................................................. 370
4x4 System ................................................................................................................................. 371
2x6, 4x4 and 4x6 Support Kits ................................................................................................... 372
4x6 System ................................................................................................................................. 373
4x12 System ............................................................................................................................... 374
Vertical Duct Systems ................................................................................................................. 375
Accessories ................................................................................................................................. 375
4x24 System .............................................................................................................................. 376
Plenum FiberGuide System.............................................................................................................. 380
System Description ..................................................................................................................... 380
Fiber Optic Cable Solutions
Introduction .................................................................................................................................... 382
Indoor/Outdoor Cable .................................................................................................................... 383
Dry Loose Tube Cables ............................................................................................................... 384
Armored Dry Loose Tube Cables: Plenum................................................................................... 385
Armored Dry Loose Tube Cables: Riser ....................................................................................... 389
Compact Building Plenum Cable .................................................................................................. 393
Plenum Cable ............................................................................................................................. 394
Armored Plenum Cable .............................................................................................................. 395
Riser Cable ................................................................................................................................. 399
Armored Riser Cable .................................................................................................................. 401
Complementary Products
Voice Grade Solutions ..................................................................................................................... 406
Series 2 Wired Termination Block System ................................................................................... 406
8-Pair...................................................................................................................................... 406
10-Pair Series 2 K110 Disconnect Block ................................................................................. 406
10-Pair Series 10 Block ........................................................................................................... 406
Series 2 Field Assembly Kits ........................................................................................................ 407
160-Pair.................................................................................................................................. 408
200-Pair.................................................................................................................................. 408
300-Pair.................................................................................................................................. 408
Series 2 Preterminated Assemblies ............................................................................................. 409
160-Pair.................................................................................................................................. 410
168-Pair.................................................................................................................................. 410
200-Pair.................................................................................................................................. 410
300-Pair.................................................................................................................................. 411
Series 2 Preterminated Blocks ..................................................................................................... 412
200-Pair.................................................................................................................................. 412
300-Pair.................................................................................................................................. 412

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling


102094AE

11/11

Table of Contents

Table of Contents
Series 2 Stubbed Disconnect Blocks ........................................................................................... 413
100-Pair.................................................................................................................................. 413
200-Pair.................................................................................................................................. 413
Series 2 8-Pair Termination Block Systems .................................................................................. 414
Grounding Blocks ................................................................................................................... 416
Type 105 Grounding block ..................................................................................................... 416
Ground Clips .......................................................................................................................... 416
Series 2 Rod Mount/Back Mount Frame Ground Kit............................................................... 416
Category 5 Patch Cords ......................................................................................................... 417
Labeling for Series 2 Blocks ........................................................................................................ 418
Type 85 Label Holder .............................................................................................................. 419
Type 85 Rod Mount Label Holder ........................................................................................... 419
Type 85 Hinged Label Holder.................................................................................................. 419
Side-Mount Label Holder........................................................................................................ 419
Type 105 Label Holder ............................................................................................................ 419
Type 105 Hinged Label Holder................................................................................................ 419
Type 105 Slotted Label Strip ................................................................................................... 419
Label Sheet for Type 85 Rod Mount Label Holder .................................................................. 421
Label Sheet for Type 85 Label Holder, Hinged Label Holder or Label Strip .............................. 421
Label Sheets in TIA/EIA-606 Colors for Type 85 Label Holder,
Hinged Label Holder or Label Strip ......................................................................................... 421
Label Sheet for Type 105 Hinged Label Holder ....................................................................... 421
Label Sheets in TIA/EIA-606 Colors for Type 105 Hinged Label Holder ................................... 421
Label Sheet for Type 105 Label Holder ................................................................................... 421
Label Sheet for Type 105 Label Strip ...................................................................................... 421
Series 2 Accessories .................................................................................................................... 422
Disconnect Plug ...................................................................................................................... 423
Flat-Top Dummy Plugs ............................................................................................................ 423
Marking Caps ......................................................................................................................... 423
Ground Clips .......................................................................................................................... 423
Cable Clamp .......................................................................................................................... 423
Disconnect Bars ...................................................................................................................... 423
8-Pair Disconnect Bar ............................................................................................................. 423
200-Pair Dust Cover ............................................................................................................... 424
Winged Test Adapter.............................................................................................................. 424
Signature Device..................................................................................................................... 424
Test Cords............................................................................................................................... 424
Series 2 Bridging Test Cord, 1-Pair with 2 Banana Plugs......................................................... 424
Series 2 Look-Both-Ways Test Cord .................................................................................... 424
Series 2 1-Pair Site-Mounted Test Cord .................................................................................. 424
NT System ....................................................................................................................................... 425
NT Termination Block System ..................................................................................................... 425
Disconnect Block .................................................................................................................... 426
Ground Block ......................................................................................................................... 426
NT to Series 2 Adapter ........................................................................................................... 426
Dummy Plug........................................................................................................................... 426
Marking Caps ......................................................................................................................... 426
Disconnect Plug ...................................................................................................................... 426
Hinged Label Holder ............................................................................................................... 426

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11/11

102094AE

TrueNet Structured Cabling

Table of Contents
Label Holder .......................................................................................................................... 426
NT 1-Pair Site Mounted Test Cord .......................................................................................... 426
NT 1-Pair Look-Both-Ways Test Cord .................................................................................. 426
NT Changeover Adapter......................................................................................................... 426
5-Position NT Back Mount Frame ........................................................................................... 427
10-Position NT Back Mount Frame ......................................................................................... 472
20-Position NT Back Mount Frame ......................................................................................... 427
30-Position NT Back Mount Frame ......................................................................................... 427
LSA Plus Insertion Tool................................................................................................................ 428
89D Style 25-Pair and 50-Pair Termination Blocks and Assemblies ............................................. 429
25-Pair Disconnect Block Assembly ........................................................................................ 429
50-Pair Disconnect Block Assembly ........................................................................................ 429
5-Pair Disconnect Block .......................................................................................................... 429
25-Pair Disconnect Block RJ-21X Connector........................................................................... 430
25-Pair Disconnect Block with RJ-71C .................................................................................... 430
25-Pair Disconnect Block with 8 RJ48X Connectors ............................................................... 431
25-Pair Disconnect Block with 12 RJ48S Connectors.............................................................. 432
25-Pair Disconnect Block with 12 RJ48S and RJ-21X Connector ............................................ 433
25-Pair Disconnect Block with 12 RJ14C and RJ-21X Connector............................................ 433
50-Pair Disconnect Block with RJ-21X Connectors ................................................................. 434
50-Pair Disconnect Block with 16 RJ48X Connectors ............................................................. 435
50-Pair Disconnect Block with 16 RJ48X Connectors Modified for Shielded Applications ..... 435
50-Pair Disconnect Block with 16 RJ48C Connectors ............................................................. 436
50-Pair Disconnect Block with 12 RJ45 Connectors................................................................ 436
50-Pair Disconnect Block with ARMM Stub ............................................................................ 437
50-Pair Disconnect Block with ARMM Stub and (2) 25-Pair Male Telco (RJ-21X)
Connectors ............................................................................................................................. 437
Disconnect Frame with ARMM Stub....................................................................................... 438
89D Style Mounting Frames ....................................................................................................... 439
19 Mounting Frame ............................................................................................................. 439
23 Mounting Frame ............................................................................................................. 439
35.5 Mounting Frame .......................................................................................................... 439
89D Style Termination Block Accessories .................................................................................... 440
50-Pair Block Center Mount Label Holder .............................................................................. 440
Clear Dust Cover .................................................................................................................... 440
Paper Labeling Strip for 50-Pair Dust Cover............................................................................ 440
Hinged Dust Cover ................................................................................................................. 440
89D Bracket for 25- and 50-Pair Blocks.................................................................................. 440
Disconnect Plug ...................................................................................................................... 441
Flat-Top Dummy Plugs ............................................................................................................ 441
Building Entrance Terminals
Fiber Wall Boxes .............................................................................................................................. 442
Indoor Fiber Distribution Terminal........................................................................................... 442
Outdoor Fiber Distribution Terminal 24 .................................................................................. 446
Outdoor Fiber Distribution Terminal 48 .................................................................................. 448
Fiber Splitter Box (FSB) ............................................................................................................ 450
FSB-16 - Indoor/Outdoor Enclosure ........................................................................................ 450
FSB-32 - Indoor Enclosure ...................................................................................................... 451
FSB-72 - Outdoor Enclosure ................................................................................................... 451

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Index .................................................................................................................................................. 465

102094AE

TrueNet Structured Cabling

Protection Devices ........................................................................................................................... 453


High-Density 5-Pin Protection ..................................................................................................... 454
25-Pair.................................................................................................................................... 454
50-Pair.................................................................................................................................... 454
100-Pair.................................................................................................................................. 454
5-Pin Indoor and Outdoor Enclosed Building Entrance Terminals ............................................... 455
25-Pair Indoor ........................................................................................................................ 456
25-Pair Outdoor ..................................................................................................................... 456
50-Pair Indoor ........................................................................................................................ 456
50-Pair Outdoor ..................................................................................................................... 456
100-Pair Indoor ...................................................................................................................... 456
100-Pair Outdoor ................................................................................................................... 456
10-Pair Magazine Protection .................................................................................................. 456
25-Pair Outdoor ..................................................................................................................... 458
50-Pair Indoor ........................................................................................................................ 458
100-Pair Indoor ...................................................................................................................... 458
10-Pair Magazine Protection Indoor and Outdoor Enclosed Building Entrance Terminals ........... 459
100-Pair Indoor ...................................................................................................................... 460
10-Pair Protection Magazine with Fail-Safe ................................................................................ 461
10-Pair Solid State Magazine with Fail-Safe............................................................................ 461
Solid-State Protector with Fail-Safe ......................................................................................... 461
Single-Pair Protectors .................................................................................................................. 462
Single-Pair System Building Entrance Terminals ..................................................................... 463
25-Pair Building Entrance Terminal, Single-Pair System ........................................................... 463
50-Pair Building Entrance Terminal, Single-Pair System ........................................................... 463
100-Pair Building Entrance Terminal, Single-Pair System ......................................................... 463

11/11

Table of Contents

Table of Contents

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling Solutions


TEs TrueNet Structured Cabling System is the integrated portfolio of high-performance copper and
fiber cable, connectivity, and cable management products from TE. The precisely tuned TrueNet system
exceeds TIA/EIA standards and provides a clear path for uninterrupted data throughput within the entire
network.

True End-to-End Solutions


The TrueNet system delivers proven cable, connectivity, and cable management solutions for fiber,
Augmented Category 6, and Category 6/5e from the data center to the desktop.

Whats TrueNet? Premier Infrastructure Solutions:


Copper solutions
Fiber solutions
Connectivity solutions
Cable management solutions
All optimized to maximize system uptime
Category 6 & 5e Ethernet

Augmented Category 6

TE's TrueNet Category 6 & 5e patch


panels, patch cords, and cable are
impedance matched to deliver extra
bandwidth and better attenuation
with zero bit errors.

TEs patent-pending CopperTen


Solution is the world's first
complete system to meet the IEEE
requirements for 10G Ethernet
over 100 meters of the UTP cable.

Fiber Connectivity
In the backbone or to the desk,
optical networks achieve peak
performance with TEs high
density frames, fiber connectors,
patch cords, raceways, and
panels featuring integrated
cable management and bend
radius protection.

Work Area Solutions


TEs high-performance modular
jacks are field-configurable for
flush, surface, and furniture
mounting applications.

Copper Cables
TEs high-performance riser and
plenum cable supports backbone
and horizontal applications. TrueNet
copper cables feature patented
AirES technology to enhance
signal speed and strength while
minimizing cable size and crosstalk.

Cable Management
Protect, route, and manage
network cables for optimized
signal integrity with TEs portfolio
of cable management, labeling,
and racking solutions.

Fiber Cables
Fiber cables including: cost
saving interlocked armored
versions, plenum rated dry
loose tube small diameter
Indoor/outdoor cables, single
mode reduced water peak, and
standard or laser optimized
multimode configurations.

www.TE.com

Applications Solutions
A global network infrastructure
leader, TE offers complete
solutions for data centers,
storage area networks, central
offices, campuses, wireless and
Wi-Fi networks, and other highperformance applications.

+1-952-938-8080

1-800-366-3891

Introduction

Introduction

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling

The typical data center is a high-performance machine constructed of thousands of components.


And like the spot welds in the frame of a car, the data center is held together and cannot function
reliably without the spot welds of structured cabling and connectivity equipment.

11/11 102094AE

Introduction

Your data center and network is the epicenter of the organization.

TIA-942 sets the data center standard.


The Telecommunications Industry Association (TIA) has published design guidelines for data center
designers in a standard known as TIA-942. Shown here, the standard breaks down the data center into
distinct sections. TE equipment depicted is typical of the equipment youll find in each of
these areas.

Horizontal
Distribution Area
LAN, SAN, and
KVM switches

Equipment
Distribution Area
Racks and Cabinets

Main Distribution
Area
Routers, Backbone
LAN/SAN Switches,
PBX, M13 Muxes

Entrance Room
Carrier Equipment
and Demarcation

Backbone Cabling
Horizontal Cabling

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling Solutions


Introduction

AirES Technology

11/11 102094AE

Introduction

TrueNet Structured Cabling

Cables for Cat 5e, Cat 6 and Cat 6a over UTP feature the patented AirES technology. AirES (Air
Enhanced System) uses air as part of the conductor insulation, which enhances signal speed and
strength while minimizing cable size and crosstalk.
AirES Cable Technology deployed in the data center: 22% smaller than typical
Augmented Category 6 cable.

TEs Plenum
CopperTen with AirES

Competitors
Augmented Category 6

Increased Uptime
Crush resistance surpasses UL 444 requirements by factor of 4
Improved electrical and physical properties
Improved airflow increases reliability and lifespan of electronics
Increased reliability by providing better circuit access

Improved Scalability
Reduced diameter yields 16-22% increase in conduit fill rates versus competitors
22% less fuel to be burned in case of fire
Better utilization of floor space
Decreased cable size
Fewer and smaller pathways

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling

Air channels within the FEP insulation are distributed evenly along the entire conductor, forming a
unified system of arched channels to strengthen the construction.

AirES cable improves attenuation due


to lower dielectric lossresulting in
smaller gauge copper than other cable.
The choice of
conductor insulation
is critical to cable
performance.
I n AirES technology, air channels
are used in the traditional FEP
insulation, which results in a 17%
better dielectric constant over
conventional FEP cables
The result: Improved data
communications in a smaller
diameter cable
22% smaller than typical
Augmented Category 6 Cable

11/11 102094AE

Introduction

Hard to Crush an AirES Cable

www.te.com/adc

+1-952-938-8080

1-800-366-3891

TrueNet Structured Cabling Solutions


Introduction

11/11 102094AE

Silver-plated contact tags at 45-degree angles across the axis of the wire make a solid, gas-tight
connection with TE's patented LSA-PLUS connectors. Insulation clamping ribs hold the wire securely and
isolate the contact area from vibration and mechanical stress. In addition, positioning contacts
at a 45-degree angle leave more wire between contact points and provides a more reliable, stress
resistant connection.

7
0 percent of network downtime is attributed to the physical layer, or cables and
connectivity equipment
The patented LSA-Plus Insulation Displacement Contact (IDC) is the highest performing, most reliable
IDC in the industry
LSA Plus technology is used throughout TEs TrueNet line in jacks, panels and termination blocks

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Introduction

TrueNet Structured Cabling

LSA-Plus

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling


11/11 102094AE

Introduction

LSA-Plus silver-plated angled contacts are the securest


available, anywhere.

Insulation clamping ribs hold the wire


securely isolating the contact area from
vibration and mechanical stress.

Silver-plated contact tags at 45-degree


angles across the wires axis make a solid,
gas-tight connection.

Axial and torsional restoring forces make a


solid, gas-tight connection.

3
1
3
2

Billions of Connections
LSA-Plus technology has been used in billions of
connections worldwide, and continues to set the
pace for others to follow.

TE leaves more wire between contact points; provides


a more reliable stress resistant connection.

Accepts 26-22 AWG insulated conductors


A
ccepts solid or stranded insulated
conductors
A
ccepts two insulated conductors of the
same type (solid or stranded) and size
(26-22 AWG)
Can be re-terminated 200 or more times

Typical primary wire after being punched into a 110


IDC; positioning contacts at a 90-degree angle results
in a weaker connection, which is prone to breakage.

LSA-Plus IDC versus 110 and 66 Block IDCs


LSA-Plus Contacts
Split beam technology
(F1=F2) = no movement
Balancing of forces eliminates the
tendency for a conductor to be forced out of
the contact over time

F1

F1

F2

F2

110-Plus IDC versus 110 and 66


Block IDCs
Wedge technology
(F2>F1) = wire movement
Unequal forces at top and bottom cause
conductor movement over time

www.te.com/adc

+1-952-938-8080

F1

1-800-366-3891

F1

TrueNet Structured Cabling Solutions


Introduction

11/11 102094AE

TrueNet Structured Cabling

TE is the only manufacturer to offer a termination block with a disconnect feature. Competitors typically
offer one solution: Closed.

T Es UL certified blocks exceed all TIA and EIA requirements. Not all of our blocks are Cat 6. Some are
Cat 3 or 5, some are Cat 5e, some are Cat 6a
Available in 5-, 8-, 10-, 20 -, 25- and 50-pair blocks
Enables a path from the cable to the jumper side of the block, which can be used to either temporarily
or permanently disconnect the circuit from cable side (top) to jumper side (bottom) via the built-in
test/disconnect port

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Introduction

Termination Blocks

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling


11/11 102094AE

Introduction

Cross-section view of TEs Ultim8 terminal block.

Normally Closed

Patching Capability
When a patch cord is inserted, the cable-side circuit
may be redirected to another location.

When a look-both-ways Test Cord is inserted, both


sides of the circuit may be tested independently.

Disconnect Feature
W
hen a disconnect plug is inserted, the
circuit is broken, either temporarily or
permanently
Disconnect port provides fault isolation,
testing and monitoring without removing
any wires

www.te.com/adc

+1-952-938-8080

Testing Feature
A
ccelerates fault isolation
Eliminates finger pointing in collocation
applications

1-800-366-3891

TrueNet Structured Cabling Solutions


Introduction

T Es Managed Density approach takes the long view of LAN, SAN and data center design with cable
management features that ensure maximum density and growth without disrupting service or adding
unneeded floor space
Managed Density ensures the network can grow today and be managed tomorrow

Active network equipment can only perform if the cables performa gigabit port is of no value if
attenuation from a damaged cable impedes performance or if restricted access delays fiber end
face maintenance.

11/11 102094AE

TrueNet Structured Cabling

The day-one savings of solutions that do not consider how to manage and grow the network
infrastructure are quickly eclipsed by outages, as well as open chassis slots and stranded network
capacity, which require new floor space.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

Introduction

Simple Density Solutions are Costly

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling

TEs Data Center Optical Distribution Frame easily scales to make the best use of expensive
floor space.

Manages up to 2,304 fiber terminations


Uses industrys highest count MPO plug-and-play cassettes
Slack storage included in each rack allows for the use of a single jumper length
MPO trunks enter rack from under-the-floor or overhead
On-frame jumper routing provides bend radius and physical protection for
easily managing slack

With Managed Density honed from


years of experience designing the
worlds largest data centers, you earn
significant benefits:
I mproved Reliability. Thorough cable management
avoids cable pile-up, mishaps in handling fibers and
other forces that damage cables and jumpers
Lowest Capital Costs. Enables efficient use of floor
space, such as fiber frames that scale to 2,304 fibers
per frame and not stranding ports on active equipment
Decreased Operating Costs. Plug-and-play cassettes,
tracing jumpers in seconds, proper technician access
add-up to fewer man hours for managing the network

11/11 102094AE

Introduction

Data Center Optical Distribution Frames

The TracerLight jumper reduces system turnup


time and improves accuracy.

FiberGuide incorporates bend-radius


protection; installs with tool-less components.
Angled left and right TFP MPO cassettes can
provide up to 24 fiber terminations.

The Optical Distribution Frame Plug-and-Play


cassette is available in 144- and 192-position
blocks.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

10

CAT 6 ALIEN CROSSTALK SAMPLE W/CLASS F LIMIT

TrueNet Structured Cabling Solutions


Introduction

AUGMENTED CAT 6 ALIEN NEXT SAMPLE W/CLASS F LIMIT

The patented star filler used for TEs


Augmented Category 6 cable, CopperTen.

FREQUENCY

Creates an oblong cable shape that produces


distance between cable pairs. In a bundle, the
oblong-shaped cable also creates natural
separation between adjacent cables.

11/11 102094AE

TrueNet Structured Cabling

FREQUENCY
TEs quest to lead the industry in innovation has resulted in an impressive record of scientific firsts. One
such first is the Augmented Category 6 cable, CopperTen.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

11

Introduction

The Worlds First Augmented Category 6 Cable

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling


11/11 102094AE

Introduction

Minimizing Alien Crosstalk


B
y effectively maintaining the distance
between the same twisted pairs, alien
crosstalk is negated in a six around
one bundle. The result: Outstanding
electrical performance in a compact,
unshielded twisted pair cable
TE designed and built the worlds first 10Gbps
solution to run over a full 100 meters, and
still leads the industry today. All of TEs
Augmented Category 6 channel solutions met
the strict performance requirements of IEEE
802.3an and ANSI/TIA/EIA-568-B.2-10

The weakest link in any channel is the patch cord.


This is especially true under the high-frequency
operation of Augmented Category 6 systems.

Your infrastructure must last 10-15 years


so should your patch cords
TE patch cords are made with stranded conductors for improved mechanical
durability
Solid conductor patch cords break when
they are over flexed
With its patch cords, TE uses a machine die
to compact individual strands in a
form that resembles a solid conductor. The
result: Electrical performance of a solid
conductor combined with the flexibility and
durability of a stranded cord

Typical Stranded
Conductor

CopperTen Stranded
Conductor

CopperTen Patch Panels


Offset jack positioning and a composite
(not metal) frame reduces alien crosstalk.

Laser tuning

CopperTen Modular Jacks


Each modular jack is laser-tuned using
an automated process performed in
Berlin, Germany. Trimming each board
guarantees performance to 500 MHz.

Laser tuning

www.te.com/adc

+1-952-938-8080

1-800-366-3891

12

TrueNet Structured Cabling Solutions


In high-bandwidth applications, signal throughput is imperative for
maintaining signal integrity.

11/11 102094AE

TrueNet Structured Cabling

True impedance matching guarantees extraordinary performance with the TrueNet cabling system.

A
ll TE systems are impedance matched to operate at tolerances of 100 3. The industry standard
is 100 15
Impedance matching allows systems to run at the highest possible performance levels
Optimizing impedance minimizes return loss and greatly reduces Bit Error Rates (BER)

TE manufactures each component of the TrueNet cabling system.


As a result, we manufacture component compliant products that are specifically tuned to maximum
throughput when used as a part of a system.
By tightly controlling the impedance of each component in the channel, the effects of Return Loss are
minimized and the Bit Error Rates (BER) plummet.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

13

Introduction

Introduction

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling

With TrueNet, you can push networks to the performance edge. Innovative products that exceed
industry standards support advanced applications such as 10GigE over UTP, VoIP, and Wi-Fi today and
tomorrow. Building upon a high-performance TrueNet infrastructure foundation, network managers and
designers are assured a flexible evolution path to next-generation technologies and services.

11/11 102094AE

Introduction

True Performance

A Tradition of Innovation
With thousands of patents worldwide, TE continually invests in innovation to support emerging
technologies and to enhance our customers network operations. In fiscal 2000 to 2003, TE invested
approximately 13% of net sales to fuel research and development.
For example, TEs innovative CopperTen solution is the worlds first Augmented Category 6 system. To
achieve high-performance specifications, CopperTen incorporates patent-pending features including a
unique oblique filler that minimizes alien crosstalk (interference from adjacent cables).
The companys patent-pending AirES technology is a critical element in the TrueNet CopperTen,
Category 6, and Category 5e solutions and results in the first and only cable design to increase
signal speed and strength while simultaneously minimizing crosstalk. AirES technology utilizes air as a
conductor insulator, eliminating the bulky fillers and extra bonding that increase cable weight, reduce
flexibility, and require extra space.

Setting the Standards


TEs TrueNet solutions meet or exceed all major cabling standards. We are actively establishing and
advocating next-generation technologies and standards worldwide through work with these leading
industry organizations:
TIA: Telecommunications Industry Association
EIA: Electronic Industries Alliance
IEEE: Institute of Electrical and Electronic Engineers
BICSI: Building Industry Consulting Service International
MEF: Metro Ethernet Forum
ISO: International Organization for Standardization
IEC: International Electrotechnical Commission
ANSI: American National Standards Institute

Training and Certification


Studies show that over 70% of network downtime can be directly attributed to physical layer problems,
specifically cabling faults. TE recognizes that proper installation of structured cabling solutions is
a critical success factor for high-performance networks. TEs network of more than 400 TrueNet
System Certified contractors and installers undergoes extensive training to ensure that TrueNet system
installations meet the most stringent industry standards.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

14

TrueNet Structured Cabling Solutions


Introduction

11/11 102094AE

TrueNet Structured Cabling

Mission-critical networks rely upon trusted TrueNet infrastructure. Built and tested in TEs world-class
facilities, TrueNet is backed by the industrys only true Zero Bit-Error Warranty that guarantees signal
integrity and throughput.

World-Class Manufacturing Expertise


TE is committed to consistently delivering the highest possible quality in all that we do. A registered
TL9000 and ISO9001:2000 manufacturer, TE is certified in 21 categoriesthe largest number of
registrations of any ISO-certified company. Additionally, TE facilities are approved to self-certify products
for compliance with UL Safety Standards.
A best-in-class manufacturer, TE operates more than 385,000 square feet of manufacturing space
in the Americas.

Backed by the TrueNet Warranty


TEs TrueNet system is backed by an industry-leading warranty that not only addresses physical
component performance, but also data throughput. Cable and connectivity solutions are tuned to
eliminate impedance mismatches to standards five times more rigorous than industry specifications.
As a result, TrueNet optimizes network speed by eliminating data retransmissions.
The TrueNet warranty covers all aspects of the structured cabling system for horizontal and backbone
networks that support voice and data. A 20-year all-inclusive industry standards compliance warranty
addresses all parts, labor, and technical support. In addition, TrueNet CopperTen Augmented Category
6 solutions carry an additional 20 year throughput warranty and the Category 6/5e and Fiber solutions
carry and additional 5 year throughput warranty that guarantees zero bit-error performance for the
entire TrueNet structured cabling channel.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

15

Introduction

True Reliability

TrueNet Structured Cabling Solutions


Introduction

TrueNet Structured Cabling

Founded in 1935, TE has served the communications industry for more than half a century and today
is a leading supplier of global network infrastructure products and services. In 2004, TE acquired the
KRONE Group, a leading global supplier of copper and fiber-based connectivity solutions and cabling
products. The integration of these two companies positions TE with annual sales exceeding $1 Billion
and an employee base exceeding 9000 professionals worldwide.
The company conducts business in more than 100 countries and operates primary facilities in
Minneapolis, Minnesota; Denver, Colorado; Sidney, Nebraska; Bennington, Vermont; Santa Teresa, New
Mexico; Delicias and Mexico City, Mexico; Berlin, Germany; Glenrothes, Scotland; Chelthanham and
Richmond, Great Britain; Shanghai, China; Berkley Vale, Australia; Cotia, Brazil; and Bangalore, India.
Customers around the world include leading communications service providers and enterprises of all
types including Bank of England, BellSouth, Bloomberg, British Telecom, Chase Manhattan, Cingular,
CitiBank, Deutsche Telekom, Glaxo Smith Kline, Hong Kong Telecom, Morgan Stanley, Nextel, Reliance
Telecom (India), Qwest, T-Mobile, SBC, Seagrams, Sprint, Verizon, and many others.

Learn More About TrueNet Structured Cabling Solutions


Within this catalog, youll find complete descriptions and ordering information for the most popular
TrueNet Structured Cabling Solutions. Because we continually enhance our product portfolio and our
specifications, we encourage you to visit our web site or contact an TE representative to keep pace with
the latest innovations.

11/11 102094AE

Introduction

About TE

www.te.com/adc

+1-952-938-8080

1-800-366-3891

16

Industry Standards ........................................................... 23


How to Choose the Right Cabling Infrastructure.............. 36
10Gigabit Ethernet over UTP ........................................... 39
Choosing the Right Ethernet Patch Panels ....................... 43
Key Fiber Optic Cable Management Concepts ................. 48

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

17

Technical Reference

Designing the Optimized Data Center.............................. 18

102094AE

TrueNet Structured Cabling

Technical Reference

Technical Reference

Designing the Optimized Data Center

Many critical decisions must be made in order to arrive at an overall data center design that
maximizes flexibility and minimizes costs. These decisions include:
Planning for the space you need today, and the space required to accommodate future growth
Establishing a well-deployed cabling setup to reduce cable congestion and confusion,
and to increase network uptime
Creating an architecture within the data center that allows for moves, adds and changes
without service disruption
Space and Layout
Data center real estate is valuable, so designers need to ensure that there is a sufficient amount
of it and that it is used wisely. This must include the following:
Ensuring that future growth is included in the assessment of how much space the data center requires
Ensuring that the layout includes ample areas of flexible white space, i.e., empty spaces within
the center that can be easily reallocated to a particular function, such as a new equipment area
Ensuring that there is room to expand the data center if it outgrows its current confines.
This is typically done by ensuring that the space that surrounds the data center can be easily
and inexpensively annexed

102094AE

TrueNet Structured Cabling

According to recent surveys, the utilization of the physical and power infrastructure in many data
centers is much less than 50 percent. This unused capacity is an avoidable capital cost, and one that
contributes significantly to unreliability and lack of flexibility in the data network.

11/11

Technical Reference

The data center is a pivotal resource in any enterprise. Most organizations simply shut down when
employees and customers are unable to access servers, storage systems and networking devices.
Businesses can lose millions of dollars in a single hour of downtime.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

18

Technical Reference

Designing the Optimized Data Center


Layout
In a well-designed data center, functional areas are laid out in a way that ensures that

Cable can be easily managed so that cable runs do not exceed recommended distances
and changes are not unnecessarily difficult
Layout Help: TIA-942

Technical Reference

TrueNet Structured Cabling

Space can be reallocated easily to respond to changing requirements, particularly growth

TIA-942, Telecommunications Infrastructure Standard for Data Centers, offers guidance


on data center layout. According to the standard, a data center should include the following key
functional areas:
One or more entrance rooms
A main distribution area (MDA)
One or more horizontal distribution areas (HDA)
A zone distribution area (ZDA)
An equipment distribution area (EDA)
Carriers

Carriers

Entrance Room
(Carrier Equip &
Demarcation)

Offices,
Operations Center,
Support Rooms

Backbone Cabling

Horizontal Cabling

Main Dist Area

Telecom Room

Backbone
Cabling

(Office & Operations


Center LAN Switches)

Computer
Room

(Routers Backbone
LAN/SAN Switches,
PBX, M13 Muxes)

11/11

102094AE

Horiz Dist Area


(LAN/SAN/KVM
Switches)

Backbone Cabling

Horizontal Cabling

Zone Dist Area

Horiz Dist Area

Horiz Dist Area

(LAN/SAN/KVM
Switches)

(LAN/SAN/KVM
Switches)

Horizontal Cabling

Horizontal Cabling

Horizontal Cabling

Equip Dist Area

Equip Dist Area

Equip Dist Area

(Rack/Cabinet)

(Rack/Cabinet)

(Rack/Cabinet)

TIA-942 Compliant Data Center

Entrance Room
The entrance room houses carrier equipment and the demarcation point. It may be inside the
computer room, but the standard recommends a separate room for security reasons. If it is housed
in the computer room, it should be consolidated within the main distribution area.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

19

Technical Reference

Designing the Optimized Data Center


Main Distribution Area

The HDA is the location of the horizontal cross-connects, the distribution point for cabling to equipment
distribution areas. There can be one or more HDAs, depending on the size of the data center and cabling
requirements. A guideline for a single HDA is a maximum of 2,000 4-pair UTP or coaxial terminations.
Like the MDA, the standard specifies separate racks for fiber, UTP and coaxial cable.
Zone Distribution Area
This is the structured cabling area for floor-standing equipment that cannot accept patch panels.
Examples include some mainframes and servers.
Equipment Distribution Area
This is the location of equipment cabinets and racks. The standard specifies that cabinets and racks
be arranged in a hot aisle/cold aisle configuration to effectively dissipate heat from electronics.

102094AE

TrueNet Structured Cabling

Horizontal Distribution Area

Data center with flexible white space

11/11

Technical Reference

The MDA houses the main cross-connect, the central distribution point for the data centers structured
cabling system. This area should be centrally located to prevent exceeding recommended cabling distances
and may include a horizontal cross-connect for an adjacent equipment distribution area. The standard
specifies separate racks for fiber, UTP and coaxial cable.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

20

Technical Reference

Designing the Optimized Data Center

Common rack frames are used throughout the main distribution and horizontal distribution areas
to simplify rack assembly and provide unified cable management.
Common and ample vertical and horizontal cable management is installed both within and between
rack frames to ensure effective cable management and provide for orderly growth.
Ample overhead and under-floor cable pathways are installedagain, to ensure effective cable
management and provide for orderly growth.
UTP and coaxial cable are separated from fiber in horizontal pathways to avoid crushing fiber
electrical cables in cable trays and fiber in troughs mounted on trays.
Fiber is routed using a trough pathway system to protect it from damage.
Racks and Cabinets
Cable management begins with racks and cabinets, which should provide ample vertical and horizontal
cable management. Proper management not only keeps cabling organized, it also helps keep equipment
cool by removing obstacles to air movement. These cable management features should protect the cable,
ensure that bend radius limits are not exceeded and manage cable slack efficiently.

11/11

Cable racks

Its worth doing a little math to ensure that any rack or cabinet provides adequate cable management
capacity. The formula for Category 6 UTP is shown below. The last calculation (multiplying by 1.30)
is done to ensure that the cable management system is no more than 70 percent full.

Formula

Cables x 0.0625 square inches (cable diameter) x 1.30 = Cable Management


Requirement.

Example

350 cables x 0.0625 x 1.30 = 28.44 square inches (minimum cable


management of 6" x 6" or 4" x 8")

www.te.com/adc

+1-952-938-8080

1-800-366-3891

21

Technical Reference

The key to cable management in the optimized data center is an understanding that the cabling
system is permanent and generic. Its like the electrical system, a highly reliable and flexible utility
that you can plug any new applications into. When its designed with this vision in mind, additions
and changes arent difficult or disruptive. Highly reliable and resilient cabling systems adhere to the
following principles:

102094AE

TrueNet Structured Cabling

Key Principles of Cable Management

Technical Reference

Designing the Optimized Data Center


Cable Routing Systems

TrueNet Structured Cabling

Ideal Rack and Cable Routing System


What is an ideal rack and cable routing system? TEs vision is illustrated below. Here are some
of the key features:
1. The FiberGuide assembly is mounted to the overhead cable racking and protects fiber optic cabling.
2. Express Exits units are mounted where they are needed, allowing flexible expansion
or turn-up of new network elements.
3. Upper and lower cable troughs are used for patch cords and jumpers, and an overhead cable
rack is used for connection to equipment located throughout the data center.
4. Eight-inch Glide Cable Manager with integrated cable management organizes cables and aids
in accurate cable routing and tracing.
5. Racks are equipped with 3.5-inch upper troughs (2RUs) and 7-inch lower troughs (4RUs), providing
adequate space for cable routing.
6. Eight-inch vertical cable managers are shown. Six-, ten-, and 12-inch cable managers are also options
to best meet the specific requirements of the data center installation and applications.
1
2

7'-0"

DSX-1
DSX-3
FIBER
ETHERNET

24"

6
5

102094AE

11/11

Technical Reference

A key to optimized cable routing is ample overhead and under-floor cable pathways. Use the underfloor pathways for permanent cabling and the overhead for temporary cabling. Separate fiber from
UTP and coaxial cables to ensure that the weight of other cables doesnt crush the more fragile fiber. For
more information on fiber cable and its proper management, see page 20.

Raised Floor
Supports Not
Shown for
Clarity

Raised Floor

Structural Floor

Fully-populated, fully-integrated lineup

www.te.com/adc

+1-952-938-8080

1-800-366-3891

22

Technical Reference
Industry Standards

The Benefits of Standards

TrueNet Structured Cabling


102094AE

11/11

Backbone Cabling
(Interbuilding)
Intermediate
Cross-Connects

Horizontal Cabling
Backbone Cabling
(Intrabuilding)

Work Area

Telecommunications
Rooms
Main Cross-Connect

The TIA/EIA-568-B Series standard defines a typical,


generic telecommunications cabling system.

Imagine trying to link railroads together that are based on different gauges, to build anything with
a combination of metric and American parts, to type a letter on something other than a QWERTY
keyboard, or to wire a building for voice, data and video if all the components had different requirements.
The key to simplifying all these tasks is standardization. Bringing standards to the wiring and cabling
segments of the building industry has enabled the industry to define a common infrastructure that allows
many companies to provide common components. Strict adherence to these standards benefits everyone.
TEs Position on Standards
TE is a strong proponent of standards-based design for structured cabling systems. A strictly
defined set of standards helps ensure uniform application of physical layer networking products
and creates a usable infrastructure for communications networks.
However, TE also believes that by nature, the standards evolve into a lowest-common denominator
indicator of performance. In order to accommodate various competing interests, a significant amount
of flexibility gets built into the allowable tolerances. The cumulative effect of these tolerances can
result in structured cabling channels in which different components can have radically different electrical
performance characteristics.
Consequently, when various standards-compliant components from randomly selected vendors are used,
the net result could be conformance to the standards, but not efficient performance.
The research undertaken by TE for the TrueNet structured cabling system revealed that only
an impedance-matched structured cabling channel that conforms to a tightly defined subset of the
performance standards is capable of flawless data transmission.
TE, as a full system supplier, is able to deliver a complete system of impedance-matched components
so there is no guesswork. Choosing standards-compliant components randomly from unrelated vendors
will yield a standards-compliant channel, but may not result in optimum network performance.
Therefore, use the standards as a design guide, then make sure that you purchase standards-compliant
matched components.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

23

Technical Reference

Entrance Facilities
and Equipment Rooms

Telecommunications
Rooms

Technical Reference
Industry Standards

TrueNet Structured Cabling


102094AE

11/11

Technical Reference

Entrance Facilities
The entrance facility provides a connection point between the outside plant facilitieswhether it is
public network services, private network customer premises or a combination of bothand the interior
premises cabling. Products used in this area include cables, connecting hardware, special protection
devices and other connecting hardware.
The demarcation point separating the service providers cabling and the customers cabling may be
part of the entrance facilities. Because the location of the demarcation point is determined by state
and federal regulations, the local regulated carrier (telephone service provider) or competitive access
provider should be contacted for detailed information.
The primary standards for this area are outlined in TIA/EIA-569-A, Commercial Building Standard
for Telecommunications Pathways and Spaces, and J-STD-607-A, Commercial Building Grounding/
Bonding Requirements.
TE manufactures special overvoltage blocks, protection devices and building entrance terminals
for both fiber and copper cabling for use in this area.
Equipment Rooms
The TIA/EIA-568-B Series standard makes a distinction between equipment rooms and telecommunications rooms because of the nature of complexity of the equipment they contain. However, an
equipment room may alternately provide any or all of the functions of a telecommunications room.
Equipment rooms provide a controlled environment to house telecommunications equipment.
This equipment may include connecting hardware, splice closures, grounding and bonding facilities
and protection devices, where applicable. Switches, routers and other active equipment may reside
in the same rack or cabinet space as the passive cabling infrastructure.
In the premises cabling backbone hierarchy, an equipment room may contain either the main
cross-connect or the intermediate cross-connect. The equipment room may also contain network trunk
terminations and auxiliary terminations that are under the control of the premises cabling administrator.
The primary standards for this area are outlined in TIA/EIA-569-A, Commercial Building Standard
for Telecommunications Pathways and Spaces.
TE manufactures a wide variety of fiber and copper patch panels, termination blocks and cable
management solutions that are well suited for this area.
Telecommunications Rooms
Telecommunications rooms may provide various functions for the cabling system and because of this
they are treated as a distinct subset in the cabling system hierarchy.
The primary function of a telecommunications room is to provide a termination point for horizontal
cable distribution, that supports all voice, data, video and other applications requiring structured
cabling. The telecommunications room also serves as a termination point for backbone cable.
The cross-connection of these two parts of the premises cabling is an important function of the
telecommunications room. Cross-connections may be accomplished using jumper wires or patch cords,
and TE products handle both methods equally well.
Telecommunications rooms may also house cross-connects for different portions of the backbone
cabling system. These cross-connects are sometimes used to tie different rooms together in a ring, bus
or tree configuration.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

24

Technical Reference
Industry Standards

Additional standards for this area are outlined in TIA/EIA-569-A, Commercial Building Standard for
Telecommunications Pathways and Spaces.
TE manufactures a wide variety of blocks and patch panels capable of providing termination and cable
management for a wide range of wire sizes and cable types found in telecommunications rooms.
For More Information
Although this catalog presents a brief overview of information contained in the standard, persons
involved with the installation and maintenance of structured cabling systems should obtain a copy of
the complete standard and/or related standards.
TIA/EIA-568-B Series Horizontal Channel/Link Model
Patch Cord

Work Area
Work Area
Cable
Telcom
Outlet

Station
Field

Equipment
Field

Data Hub

FUSE
ON

Transition
Point
(Optional)

3M (Max)

Station Cable

OFF

Equipment Cable

90M (Max)

7M

B
A + B < 10M

ISO/IEC 11801 Horizontal Channel/Link Model


Patch Cord

Work Area
Work Area
Cable

11/11

Telcom
Outlet

Station
Field

Equipment
Field

Data Hub

FUSE

ON

Transition
Point
(Optional)

Station Cable

90M (Max)

OFF

Equipment Cable

5M (Max)

A + B + E < 10M

www.te.com/adc

+1-952-938-8080

1-800-366-3891

25

Technical Reference

The TIA/EIA-568-B Series standard details cable routing and installation practices for telecommunications
rooms to prevent cable stress and to properly organize and manage cables.

102094AE

TrueNet Structured Cabling

Telecommunications rooms also provide a controlled environment for specific areas of a building. These
rooms may house telecommunications equipment, connecting hardware and splice closures as well as
devices such as routers and hubs. In some instances, the demarcation point and protection devices may
be located in a telecommunications room.

Technical Reference
Industry Standards

Technical standards that address various aspects of commercial cabling include:


TIA/EIA-568-B Series, Commercial Building Telecommunications Cabling Standard
TIA/EIA-569-A, Commercial Building Standard for Telecommunications Pathways and Spaces

J-STD-607A, Commercial Building Grounding/Bonding Requirements


For information on obtaining copies of any of these standards, please contact:
Global Engineering Documents
800.854.7179 or 303.397.7956
www.global.ihs.com
ISO 11801 (International Standard)
www.iso.ch
NEC (National Electrical Code),
written and distributed by the National Fire Protection Association (NFPA)
www.NFPA.org
A discussion of standards affecting the design and layout of a standards-based data center, as well as
TEs recommendations for assuring that your data center supports the demands of, and grows with,
your network, follows on page 45.

102094AE

TrueNet Structured Cabling

TIA/EIA-606-A, Administration Standard for the Telecommunications Infrastructure


of Commercial Buildings

11/11

Technical Reference

TIA/EIA-570-A, Residential Telecommunications Cabling Standard

www.te.com/adc

+1-952-938-8080

1-800-366-3891

26

Technical Reference
Industry Standards

Interconnection vs. Cross-Connection

11/11

102094AE

Cross-Connection

Technical Reference

TrueNet Structured Cabling

Interconnection

The TIA/EIA-568-B Series standard addresses two basic wiring schemes for the telecommunications
room: interconnection and cross-connection.
Both the backbone and the horizontal cabling are terminated on connecting hardware that meets
the requirements of the TIA/EIA-568-B Series standard. However, the standard prohibits the use of these
terminations for moves, adds and changes. Any connection between the backbone and horizontal
cabling must be accomplished through the use of a horizontal cross-connect between the common
equipment and the connecting hardware to which the horizontal cabling is terminated. This connection
may be made using an interconnection or a cross-connection cabling scheme.
An interconnection is a cabling scheme that provides for a direct connection between two cables
without the use of patch cords or jumper wires.
A cross-connection is a cabling scheme between cabling runs, subsystems and equipment using
patch cords or jumper wires that attach to connecting hardware on each end.
Common equipment that utilizes cables that extend an individual port may be permanently terminated
or interconnected to the connecting hardware for the horizontal cabling. Direct interconnections such as
this reduce the number of connections in a channel, but may also reduce the flexibility, especially as the
volume of moves, adds and changes increases.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

27

Technical Reference
Industry Standards
Backbone Cabling

TrueNet Structured Cabling

The TIA/EIA-568-B Series standard requires that backbone cabling use a hierarchical star topology.
Each horizontal cross-connect in a telecommunications room is cabled to an intermediate crossconnect and then to a main cross-connect (or directly to a main cross-connect), with no more than two
hierarchical levels of cross-connect in the backbone cabling. These cross-connects may be located in
telecommunications rooms, equipment rooms or entrance facilities.
Recognized cables for use in backbone
cabling include the following:

100 Ohm UTP (unshielded twisted pair)


cable (four or more pairs)

150 Ohm STP-A (shielded twisted pair) cable

62.5/125m, multimode optical fiber cable


Backbone cabling uses a hierarchical star topology.
50m, multimode optical fiber cable

102094AE

Singlemode optical fiber cable

50m, laser optimized multimode fiber optic cable


(300m & 550m)

11/11

Technical Reference

Backbone cabling provides interconnections between the telecommunications rooms, equipment


rooms and entrance facilities. Backbone cabling consists of cables, main and intermediate cross-connects,
mechanical terminations and patch cords or jumper wires. Backbone cabling can be within buildings
(intrabuilding) or between buildings (interbuilding).

Intermediate
Cross-Connects
Telecommunications
Rooms
Main Cross-Connect

www.te.com/adc

+1-952-938-8080

1-800-366-3891

28

Technical Reference
Industry Standards
Horizontal Cabling

11/11

102094AE

Voice service
Internet service
Video and conferencing services
Premises switches, routers and hubs
Data communications to support fax,
storage servers, network printers
Local area networks (LANs)
Life safety systems such as security,
fire alarm and door entrance
Automation systems such as lighting
and HVAC control
Other building signaling systems,
such as CCTV, nurse call, paging,
audio and others

Technical Reference

TrueNet Structured Cabling

Horizontal cabling extends from the work area telecommunications outlet to the horizontal cross-connect
in the telecommunications room. Horizontal cabling includes the cables, the telecommunications outlet
in the work area, the mechanical termination and patch cords or jumper wires and cable management
solutions located in the telecommunications room.

Intermediate
Cross-Connects
Telecommunications
Rooms
Main Cross-Connect

Relocation of offices is a common occurrence in enterprises. Horizontal cabling is often one of the
more dynamic areas of the premises system. However, after installation, horizontal cabling is often much
less accessible than backbone cabling, and the time, effort and skills required to change or modify it
can be extremely high. Horizontal cabling should be designed with the intention of minimizing ongoing
maintenance and relocation so that moves, adds and changes can be accomplished from the telecommunications and equipment rooms. Additional consideration should be given to accommodating a wide
range of applications in order to reduce the necessity of changes to the cabling as users needs evolve.
Care should be given to separate telecommunications cabling from electrical facilities that generate
high levels of electromagnetic interference (EMI). Fluorescent lights, copy machines, heating/cooling devices,
motors and transformers that support the buildings mechanical requirements all contribute to EMI. TIA/
EIA-569-A specifies separation of horizontal cabling pathways from common sources of EMI.
Horizontal cabling is required to use a star topology. Each work area telecommunications outlet is to be
connected to a horizontal cross-connect in the telecommunications room. Each work area is to be served
by a telecommunications room.
Maximum Distances
The maximum distance of a copper horizontal cabling run is 90 meters (approximately 295 feet) from
the mechanical termination at the horizontal cross-connect in the telecommunications room to the
telecommunications outlet in the work area.
Cross-connect jumper wires and patch cords used in the cross-connect facilities should not exceed
six meters in length (approximately 20 feet).

www.te.com/adc

+1-952-938-8080

1-800-366-3891

29

Technical Reference
Industry Standards
Horizontal Cables

TrueNet Structured Cabling

100 Ohm UTP (unshielded twisted pair)


cable (four or more pairs)

150 Ohm STP-A (shielded twisted pair) cable

62.5/125m, multimode optical fiber cable

50m, multimode optical fiber cable

50m, laser optimized multimode fiber optic cable


(300m & 550m)
Color Codes for Horizontal 100 Ohm
UTP Cable or for Patch Cords

Pair 1 = White-Blue/Blue

Pair 3 = White-Green/Green

Pair 4 = White-Brown/Brown

102094AE

Pair 2 = White-Orange/Orange

11/11

Technical Reference

Recognized cables for use in horizontal


cabling include the following:

www.te.com/adc

+1-952-938-8080

1-800-366-3891

30

Technical Reference
Industry Standards
Work Area

The length of cords used in the work area are assumed to be no longer than three meters (approximately
9.8 feet) in establishing the maximum length for the horizontal cabling of 100 meters total, and the cords
should meet or exceed the requirements for patch cords outlined in the standard.
Common patch cords used in the work area have identical connectors on both ends, but cords may
vary widely in design depending on the application. Often adapters are required to accommodate
specific equipment.
Types of adapters include:
Special adapters to mate an equipment connector
to the telecommunications outlet when they are different
styles (e.g. baluns)
A Y adapter to branch two services
off of a single cable
Adapter which transpose pairs for compatibility
Adapters for equipment that requires
termination resistors

Intermediate
Cross-Connects
Telecommunications
Room

11/11

102094AE

Main Cross-Connect

These and other types of adapters can have a detrimental effect on the transmission performance
of the telecommunications cabling system. It is important to consider the compatibility of these adapters
to premises cabling equipment before connecting them to the network.
A successful, high-performance premises wiring system requires more than simply purchasing the proper
standards-compliant cables and hardware. Care must be taken to ensure that the components are
installed properly according to industry-recognized practices.
Performance specifications called out in the TIA/EIA-568-B Series standard are based on the assumption
that proper installation techniques and management practices have been followed. If recommended cabling
precautions and installation methods are not observed, specified transmission capabilities of cabling
components may not be achieved.
Installation should be performed by trained, certified installers such as the authorized TE Cabling System
Certifiers who are authorized to provide an TE product and performance warranty.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

31

Technical Reference

TrueNet Structured Cabling

The work area components of a premises cabling system are the most visible to office workers. Work
area components extend from the telecommunications outlet to the station equipment, such as traditional
telephones, VolP devices, networked computers, fax machines and shared devices such as network printers.

Technical Reference
Industry Standards

TrueNet Structured Cabling

DONT

Do pull cables to minimize the distance


of the run and eliminate large loops.

Dont exceed 110 Newton's (25 lb/f)


of pulling forces when running cables.

Do bundle cables in a neat, orderly


fashion, and use hook-and-loop ties.

Dont cinch cable bundles too tightly,


or use plastic cable ties.

Cable Diameter + d

Radius = 4 x d

Do follow recommendations for cable


bend radius. In spaces with UTP terminations,
cable bend radius should not be less than
four-times the cable diameter for horizontal
cable, and should not be less than ten times
the cable diameter for multipair cable.

Dont ever bend or kink cable too sharply.

Do make sure that pair twists are maintained within 1/2" (12mm) or less of the
termination point.

Dont untwist pairs when terminating.

102094AE

DO

11/11

Technical Reference

Cable Installation

www.te.com/adc

+1-952-938-8080

1-800-366-3891

32

Technical Reference
Industry Standards

R1 T1
R3
T3
R2
T4
R4
T2

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

T568A RJ45

T568B RJ45

R1
T1

R2

R1 T1
T2
R2

12345678

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

10Base-T

Token Ring

TP-PMD

R1 T1

R1 T1
T2
R2

R1 T1
T2
R2
T3
R3

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

USOC RJ11

USOC RJ14

USOC RJ25

R1

T2

11/11

R1
T1

T2
R2

R1 T1
T2
R2
T3
R3
T4
R4

1 2 3 4 5 6 7 8

Position 1
Shorts to
Position 4

USOC RJ61

www.te.com/adc

Position 2
Shorts to
Position 5

USOC RJ48X

+1-952-938-8080

1-800-366-3891

33

Technical Reference

R1 T1
T2
R2
R3
T4
T3
R4

102094AE

TrueNet Structured Cabling

Jack Pin-Outs

Technical Reference
Industry Standards

25-Pair Cable Color-Coding

TrueNet Structured Cabling


102094AE

11/11

Technical Reference

Pair
Number

Cable
Color

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

www.te.com/adc

Color
Coding

Tip &
Ring

50-Pin
Positions

66 or 110
Positions

White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
Brown/White
White/Slate
Slate/White
Red/Blue
Blue/Red
Red/Orange
Orange/Red
Red/Green
Green/Red
Red/Brown
Brown/Red
Red/Slate
Slate/Red
Black/Blue
Blue/Black
Black/Orange
Orange/Black
Black/Green
Green/Black
Black/Brown
Brown/Black
Black/Slate
Slate/Black
Yellow/Blue
Blue/Yellow
Yellow/Orange
Orange/Yellow
Yellow/Green
Green/Yellow
Yellow/Brown
Brown/Yellow
Yellow/Slate
Slate/Yellow
Violet/Blue
Blue/Violet
Violet/Orange
Orange/Violet
Violet/Green
Green/Violet
Violet/Brown
Brown/Violet
Violet/Slate
Slate/Violet

Tip 1
Ring 1
Tip 2
Ring 2
Tip 3
Ring 3
Tip 4
Ring 4
Tip 5
Ring 5
Tip 6
Ring 6
Tip 7
Ring 7
Tip 8
Ring 8
Tip 9
Ring 9
Tip 10
Ring 10
Tip 11
Ring 11
Tip 12
Ring 12
Tip 13
Ring 13
Tip 14
Ring 14
Tip 15
Ring 15
Tip 16
Ring 16
Tip 17
Ring 17
Tip 18
Ring 18
Tip 19
Ring 19
Tip 20
Ring 20
Tip 21
Ring 21
Tip 22
Ring 22
Tip 23
Ring 23
Tip 24
Ring 24
Tip 25
Ring 25

26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
50
25

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

+1-952-938-8080

1-800-366-3891

34

Technical Reference
Industry Standards
Wiring to Standards

TIA/EIA T568B
TIA/EIA T568A
TIA/EIA T568B
TIA/EIA T568A
Standard StandardStandard Standard

TrueNet Structured Cabling


102094AE

11/11

Pair 3

Pair 1

1 2

3 4 5

Pair
34
Pair

Pair 3

Pair 3

PairPair
1 2 PairPair
4 1

6 17 2 8 3 4 51 62 73 84 5

Pair
Pair2 4

Pair 1

6 17 2 8 3 4 5

Pair 4

6 7

BLO OOW-WBRGBR
W-G G W-O BL W-BL OWW-GBRG BRW-O BL W-WBL W-BL GWW-OBROBRW-G BL W-BL G W-BR BR

RJ45 Jack PositionsRJ45 Jack Positions


RJ45 Jack PositionsRJ45 Jack Positions
T568A
T568B
T568A
T568B

The TIA/EIA-568-B Series Commercial Building Telecommunications Wiring Standard defines pin/pair
assignments for eight-position modular jacks in the work area. The preferred wiring configuration is
T568A. A second, optional configuration, T568B, is allowed to accommodate certain eight-pin wiring
systems already in use (specifically AT&T 258A or WECO wiring).
For modular RJ45 patch cords, 568A or 568B wiring are both usable, regardless of which wiring scheme
is used in the horizontal cabling.
A crossover cord is wired T568A on one end and T568B on the other, and is typically used for peer
to peer networking or to connect stacked hubs or switches. Many active devices now have a switch that
crosses one port, negating the need for a crossover cable.
Wiring schemes also raise a variety of questions:
Q:
A.

Whats the difference between T568A and T568B?


The only difference is the positioning of the Green and
Orange pairs of wires.

Q:
A:

Is there a performance difference between T568A and T568B?


No. Both wiring schemes have to meet the same
performance criteria.

Q:
A:

Why two schemes?


The reason is outside of the scope of this discussion but it is related
to old telephone legacy issues. All you really need to know is that
there are two schemes, and how to deal with them.

The solution really is fairly simple: Just pick one wiring scheme and use it consistently throughout
your network. The only problem you would ever encounter would be if the two wiring schemes were
accidentally mixed in an installation. T568B is the predominate scheme in the United States; T568A
is popular in Canada and in many other countries. The safest way to determine which to use is to
check with the network equipment provider to determine the predominant wiring scheme used in the
equipment. The reason for this check is quite simple: you can change the wiring scheme used in the
network but you cannot change the wiring scheme used in the network equipment.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

35

Technical Reference

Pair 2

Pair 2

Technical Reference

How to Choose the Right Cabling Infrastructure

TrueNet Structured Cabling


102094AE

Over the past 30 years there have been unprecedented advances in networking technology. Since the
early 1970s with the development of Ethernet, rates for point-to-point data transfer have increased by
a factor of ten thousand. From one Mb/s StarLan to 10 Gb/s Ethernet, the steady increase in bandwidth
has been fueled by an ever increasing demand for more; more speed, more applications, more memory
and more devices.
Demand for faster speed comes from continual increases in processor capability and advanced
operating systems that enable development of new applications. These applications and their associated
devices create more network usage and congestion, driving demand for more bandwidth. The need for
this additional bandwidth is seen first at network bottlenecks. When a section of the network becomes
a bottleneck, network equipment, such as Ethernet switches and servers, are replaced with the next
generation of equipment with faster processors, more memory, improved operating systems and the
inherent ability to run more complex applications.
Over time, network equipment speeds outpace the infrastructure that connects the devices; In the
transition of 10Base-T to 100Base-TX, for example. Networks with category 3 cabling systems could
support the first few generations of switches and computers that supported 10 Mb/s Ethernet over 100
meters. With the introduction of the 100Base-TX protocol, bandwidth limitations between devices were
removed. However, category 3 cabling was insufficient to support the 10x increase in data rate, which
led to the development of category 5 cabling to support 100 Mb/s over 100 meters.
Ignoring category 4, which came and went quickly, network planners faced a decision on which cabling
system to install. At that time, the majority of networks operated with 10Base-T network devices. Yet
category 3 cabling would not support the emerging 100Base-TX protocol. The good news, however,
was that category 5 would run 100Base-TX and was backward compatible with category 3. In other
words, any application designed for category 3 (10Base-T) would run just as well, if not better, on
category 5 cabling systems. The logical choice was to install category 5 in anticipation of applications
requiring 100Base-TX.
Selecting the Infrastructure: Follow the Lead of IEEE
The same scenario faces network planners today as cabling systems are designed to withstand
multiple replacements of active equipment. Most active network equipmentincluding computers,
servers, Ethernet switches, routers and hubshave a maximum useful life of three to five years before
they become obsolete. In contrast, structured cabling historically has a useful life of 10 to 15 years.
Therefore, the structured cabling you install today must outlive at least three generations of networking
equipment upgrades.
The challenge is how to determine what types of active equipment will exist in three product
generations; the answer can be found with IEEE. This organization consists of networking, equipment
manufacturers such as Cisco, Nortel, Juniper and others that look at the future of networking, and
develop solutions for future product generations. Using IEEE standards as a guide, it is possible to see
the direction for both active equipment and cabling requirements for the next few generations.

11/11

Technical Reference

A Brief History of Cabling

IEEE has already released standards for 10GbE over optical fiber, over short range copper (CX4), and
twisted pair copper.
With the advent of these
new standards it is clear
that the IEEE has set a
direction that 10GbE

www.te.com/adc

IEEE Standards Activity


IEEE 802.3z

Gigabit Ethernet over Fiber

Released 1998

IEEE 802.3ab

1000Base-T (Gigabit Ethernet over UTP)

Released 1999

IEEE 802.3ae

10GbE over Fiber

Released 2002

IEEE 802.3ak

10GbE over short range Copper (CX4)

Released 2003

IEEE 802.3an

10Gbase-T (10GbE over Copper)

Released 2006

+1-952-938-8080

1-800-366-3891

36

Technical Reference

How to Choose the Right Cabling Infrastructure


over UTP is going to be a reality in upcoming generations of network equipment and this is fully
supported by the standards making bodies, TIA and ISO.

11/11

102094AE

The questions remain: with all the fiber and copper cabling choices at your disposal, which do you
install today? There is no simple answer, because each network is unique. Beware of one-size-fits-all
solutions as they cannot possibly account for the infinite numbers of variables you must consider when
selecting your cabling infrastructure.
As you make your cabling infrastructure decisions, keep in mind your bandwidth requirements and the
timing of your implementation. The following are just three possible scenarios based upon very different
network requirements:
Scenario 1: You need 10 GbE right now. If this is the case, choose Augmented category 6 cable
or 10GbE over fiber. Fiber can be more expensive than copper, due to media conversion and more
expensive ports on equipment, but. 10GbE fiber ports are readily available today from most major
switch manufacturers. 10GBASE-T products for Augmented Category 6 products are in their infancy, as
of this publication, but will become more main stream in the coming years..
Scenario 2: You are occupying the space for the short-term only. Your plan is to move in the next two
to three years. In this case, the logical choice is a category 6 cabling solution. You will not be in the
building long and category 6 will support 10GbE at the shorter distance of 37 meters, just in case you
do require 10GbE in the near term.
Why is category 5e not a good choice in this scenario? Back in 2005, the dominant UTP cabling
standard for new installations shifted from category 5e to category 6. In addition, category 5e is not
recognized by IEEE or TIA to support 10GBASE-T because category 5e cannot support 10GbE for any
practical distance.
Scenario 3: Building space is on a long-term lease or the building is owned; bandwidth requirements
are substantial. Choose Augmented category 6. History says your upfront investment will pay off in the
long-term. Augmented category 6 will be more expensive than category 6, however, the installation
time and cost will be virtually the same. In this scenario, Augmented category 6 offers a cabling
system that will be in service for at least three generations of active network gear. In the scope of any
networking project, the infrastructure is a relatively small expense. Adding the small capital expense for
Augmented category 6 cabling will defer or eliminate future costs of cabling system upgrades as new
applications require replacement of active networking gear.
Building For Bandwidth in the Future
Technology advancements in networking will continue. New processor technology, coupled with new
operating systems, will allow the creation of advanced applications and services. These new applications
will demand more and more bandwidth, driving the need for higher speed protocols and cabling to
support these protocols. Your situation may dictate a fiber or a category 6 solution. Yet if you own your
space, or have a long term lease, a good rule of thumb is to design your passive cabling infrastructure
to endure at least three generations of active networking gear with an Augmented category 6 solution.
To design for three generations, look to the IEEE and educate yourself on the applications being
developed for the future. This offers an invaluable guide toward building for bandwidth in the future.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

37

Technical Reference

TrueNet Structured Cabling

Focus on the Critical Decision Criteria

Technical Reference

Choosing the Right Cabling Infrastructure

The chart below shows just a few of the TE cable solutions used to support common enterprise
applications. Integral to each solution are the TrueNet patch panels, fiber frames, connectors, cable
management, termination/splice/storage panels and other products for every unique requirement in the
passive portion of your network.

IEEE
Standard

Designation

Data
Rate

Distance
Limitation

Common
Applications

TE TrueNet Solutions

802.3ab

1000Base-T

1000 Mb/s

100 meters

Desktop Computing

Category 5e and 6
CopperTen Augmented
Category 6

802.3z

1000Base-SX

1000 Mb/s

550 meters

Enterprise backbone
WAN, MAN

Laser Optimized
Multimode Fiber
Singlemode Fiber

1000Base-LX

1000 Mb/s

5 Kilometers

802.3an

10GBase-T

10 Gb/s

100 meters (Cat 6a), Data Center, R&D Computing,


55 meters (Cat 6)
High Resolution Video,
Advanced Desktop Computing

CopperTen Augmented
Category 6
Category 6

802.3ae

10GBase-SR/SW 10 Gb/s

300 meters

10GBase-LR/LW 10 Gb/s
10GBase-ER/EW 10 Gb/s
10GBase-LX-4
10 Gb/s

10 Kilometers
40 Kilometers
300 meters

10GBase-LX-4

10 Gb/s

10 Kilometers

Data Center and Enterprise


Backbone Cabling
WAN, MAN
WAN
Data Center and Enterprise
Backbone Cabling
WAN, MAN

Laser Optimized
Multimode Fiber
Singlemode Fiber
Singlemode Fiber
Standard Grade
Multimode Fiber
Singlemode Fiber

Power over
Ethernet

10/100/
1000 Mb/s

100 meters

VoIP, WiFi, RFID, IP Security

Midspan PoE

802.3af

102094AE

TrueNet Structured Cabling

TE manufactures and distributes a complete portfolio of standards-based, technologically superior


solutions that support voice, data, security, audio, video, controls and other building and campus
systems. The TrueNet Structured Cabling Solution provides a complete copper and fiber cable,
connectivity and cable management solution from the entrance facility to the desktop and across the
campus. Supported by an exceptional warranty, TrueNet is the choice of network managers worldwide
who operate high-value and mission-critical networks.

11/11

Technical Reference

TE Infrastructure Solutions

www.te.com/adc

+1-952-938-8080

1-800-366-3891

38

Technical Reference

10Gigabit Ethernet over UTP: CopperTen Cabling Solution

If Fiber is always one step ahead, why doesnt it replace copper as the preferred medium for networks?
The answer is simple: The cost of the active electronics. The process of converting electrons to photons
and then photons back to electrons adds cost. This added cost translates into higher cost for active
electronics. In traditionally wired networks, the cost of the fiber active hardware is as much as three times
greater than copper active hardware. The cost of deploying fiber versus copper structured cabling is quite
similar, depending on the grade of cable selected.
The IEEE 802.3 develops the electrical parameters need to run Ethernet applications. The IEEE then
passes on the requirements to the Telecommunications Industry Association (TIA) and the International
Standards Organization (ISO) for developing measurable parameters for cabling infrastructure.
For 10GBASE-T (10 Gigabit Ethernet over Twisted Pair cabling), the IEEE published IEEE 802.3an in
September of 2006. The TIA and ISO organizations followed suit by ratifying TIA-568-B.2-10 and ISO
11801:2002 amendment 1 in February of 2008. With the committees having ratified their documents,
all the rules are in place to properly install a structured cabling infrastructure for any 10 Gigabit Ethernet
environment.
Augmented Category 6 (Cat 6a)
The frequencies needed to support the encoding schemes for 10GBASE-T now extend to 500MHz.
Signal-to-noise ratio within a cabling solution is easily predicted, and therefore cancelled out within the
active electronics. A random noise source, cable-to-cable (alien crosstalk), now needs to be measured and
reduced for 10GBASE-T to run properly.
To prevent the effects of crosstalk within cables, pairs within a single cable are twisted at different rates
(as the different colors in the cable would indicate). These different rates are used to minimize the
crosstalk between pairs along parallel runs. While this works well within the cable, it doesnt do much
for alien crosstalk.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

39

Technical Reference

Fiber typically leads the Ethernet industry into the next generation of products. Currently, IEEE is
working on the proposed IEEE 802.3ba standard: 40Gbps for local server applications and 100Gbps
for Internet backbones. The proposed standard includes LASER Optimized multimode fiber (LoMM),
single-mode fiber and copper as mediums over which the application must operate. This is the first time
that copper has been included with fiber in the progression of port speed. The document is anticipated
to be ratified by 2010.

102094AE

TrueNet Structured Cabling

For years, copper Unshielded Twisted Pair (UTP) solutions have been the preferred medium over which
most networks communicate. During this same period, a debate raged over the time frame fiber optic
cabling would replace copper cabling as the preferred medium for network infrastructure.

Technical Reference

10Gigabit Ethernet over UTP: CopperTen Cabling Solution

TrueNet Structured Cabling


102094AE

11/11

Technical Reference

Alien crosstalk is quite simply the amount of noise measured on a pair within a cable induced from
an adjacent cable. This is not only a concern for different twist lay pairs between cables, but more so
between same twist lay pairs between adjacent cables.

Example of a center cable being impacted


by the adjacent 6 cables in the bundle.

Example of how cables with same twist


lays impact one another.

The star filler used within several Cat 6


cable designs increases and controls the
distance between pairs.

While the distance between pairs within the same


cable is maintained, the distance between same lay
lengths on adjacent cables is still compromised.

Initial testing on existing Category 6 UTP cable designs quickly showed that the rationale behind reducing
the impact of crosstalk between pairs within a cable could not support alien crosstalk requirements. Twist
lay variation and controlled distances between the pairs have been standard design practice for achieving
Category 6 compliance. While the distance between pairs can be controlled within a cable jacket,
it could not be controlled between same lay length pairs on adjacent cables.
Testing to Shannons capacity on existing Category 6 UTP solutions only yielded results in the 5Gbps
range. The results achieved previously did not provide the needed additional throughput to allow for
active electronic anomalies. This was a far cry from the desired 18Gbps. Therefore the question was
asked: Is there a UTP solution capable of achieving the needed alien crosstalk requirements or would
fiber finally rule the day? The August 2003, meeting of the working group would yield three main
proposals:
1. Lower the data rates to 2.5Gbps for Category 6 UTP. This would be the first time fiber would
not be matched in speed and that a tenfold increase in speed would not be achieved.
2. Reduce the length of the supported channel to 55 meters from the industry standard 100 meters
for Category 6 UTP. This would greatly impact the flexibility of the cabling plant, considering most
facilities are designed with the 100 meter distance incorporated into the floor plans.
3. Use shielded solutions and abandon UTP as a transport medium for 10GBASE-T. This would mean
returning to F/UTP or S/FTP type solutions, requiring additional labor, product cost and grounding,
as well as space.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

40

Technical Reference

10Gigabit Ethernet over UTP: CopperTen Cabling Solution


TE's CopperTen Solution: A 100 Meter Solution for 10GBASE-T

In CopperTen, the pairs are now kept apart by creating


a higher degree of separation through a unique oblique star filler design. Crowned high points are
designed into the filler to push the cables away from one another within the bundle. This is very similar
to rotating a cam lobe.
Due to the oblique shape of the star, the pairs remain close to the center, while remaining off-center
as the cable rotates, creating a random oscillating separation effect. The bundled cables now have
sufficient separation between same lay length (same color) pairs to prevent alien crosstalk.

Oblique, elliptical,
offset filler, which
rotates along its
length to create an
air gap between
the cables within
a bundle.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

41

Technical Reference

The often-used star filler pushed the pairs within


the cable as close to the jacket as possible leaving
same pair combinations between cables susceptible
to high levels of crosstalk.

102094AE

TrueNet Structured Cabling

With standard Category 6 cable construction, the


pair separation within the cable is counter-productive
for pair separation between cables.

Technical Reference

10Gigabit Ethernet over UTP: CopperTen Cabling Solution


FREQUENCY

TrueNet Structured Cabling

This effect is even more dramatic when viewed


from the side of a cable bundle. The peaks of the
oblique, elliptical filler (red arrows) are used as
the contact points along the length of the run.
These provide the greatest distance between the
actual pairs by vaulting the sides of the ellipse
(yellow arrows) where the pairs are housed.

CAT 6 ALIEN CROSSTALK SAMPLE W/CLASS F LIMIT

The reduction of alien crosstalk is now greatly improved over the standard Category 6 cable with
the new CopperTen cable. The improvements are approximately 20dB better on CopperTen cable than
standard Category 6 cable. To put this in perspective: for every 3dB of extra noise theres a doubling
effect resulting in standard Category 6 cable being more than six times noisier than CopperTen cable.
FREQUENCY

102094AE

CAT 6 ALIEN CROSSTALK SAMPLE W/CLASS F LIMIT

AUGMENTED CAT 6 ALIEN NEXT SAMPLE W/CLASS F LIMIT

FREQUENCY

FREQUENCY

11/11

Technical Reference

The separation can be better understood through the actual cross section below. The unique design
keeps cable pairs of the same twist rate within different cables at a greater distance from one another
than in the past. Similar to the patented AirES technology cable design, air is used between these pairs.

For the purpose of comparison, the Category 7 limit line was used to show the dramatic improvement
in preventing alien crosstalk.
AUGMENTED CAT 6 ALIEN NEXT SAMPLE W/CLASS F LIMIT

The industry now has taken the next leap. Copper UTP has been given another lease on life to support
the next future proofing step in extending ethernet applications.

FREQUENCY

www.te.com/adc

+1-952-938-8080

1-800-366-3891

42

Technical Reference

Choosing the Right Ethernet Patch Panels


Category 5e, 6, or Augmented Category 6? IDC punchdown or modular? T568A or T568B?
Shielded or unshielded?

With all the choices you face as you design your network and select equipment, including available
Ethernet patch panels, its easy to become confused and frustrated. Ultimately your choice of Ethernet
panels should fit the applications you plan to run. TE has written this short tutorial to guide
you through these decisions, to make them as painless as possible and offer you the best solution
for your network.
First, lets ask a few key questions. Your answers will help guide you in the decision process.
Next, we will briefly discuss each of the most popular options available so you can draw conclusions
based on your network needs.
Discovery Questions
What applications are you or do you plan to run in this facility? Take into account not only
what you are doing today, but what you probably will be doing tomorrow i.e. 10/100Base-T?
1000Base-T? 10GBase-T?
What type of LAN network are you designing? Data center? Data backbone? Workstation?
Is the project a new network installation or an addition to an existing network?
Is the installation being built to expand existing capacity with current data capabilities or is it
for new, faster data applications?
Answers to these questions will guide you to a particular cable type, a particular data patch panel,
and the means to terminate the cable into the patch panelwhether the terminations into the patch
panel involve punchdown cable terminations, pre-made telco-type multi-pair cable ends, or standard
RJ45 cable ends.
The general guidelines for network transmission capabilities segment the data network; data center
and data network backbone system applications require the highest level of transmission capabilities,
while feeds to work areas generally require a bit less. However, all network connectivity should be
designed with only the highest network engineering standards available.

Category 5e, 6 and 6a Cabling


The Telecommunications Industry Association (TIA) standards group consists of a variety of industry
experts including connectivity and cable manufacturers, distributors, installers, and end customers.
The TIA determines certain transmission characteristics that must be met to qualify a cable for certain
network applications.
Category 5e is currently the minimum TIA recommended category of wiring for new installations.
Electrical characteristics for NEXT, FEXT, ELFEXT, PSNEXT, PSELFEXT, delay skew, propagation delay,
attenuation, and return loss are specified to 100MHz. Category 5e was developed with the specific
intent of supporting Gigabit Ethernet. Because all TIA standards require backwards compatibility,
Category 5e will also support all lower-rated categories and protocols such as 10/100 Base-T.
Category 6 is gaining popularity for new installations. Electrical characteristics for NEXT, FEXT, ELFEXT,
PSNEXT, PSELFEXT, delay skew, propagation delay, attenuation, and return loss are specified to 250MHz.
Improvements in all electrical parameters are part of the higher TIA Category 6 standard. Category 6,
while providing a bigger pipe for improved throughput, also has a maximum 100 meters of support
for Gigabit Ethernet transmission.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

43

Technical Reference

How do I ensure the integrity of my network? Can the infrastructure grow and change without
service disruptions?

11/11

102094AE

TrueNet Structured Cabling

Will I choose the right Ethernet patch panel for my application? Will this choice work with future
applications? Am I getting the best overall value?

Technical Reference

Choosing the Right Ethernet Patch Panels

TrueNet Structured Cabling


102094AE

Category 7 is a proposed standard for a fully shielded, 4-pair cabling system with transmission
specifications referenced to 600MHz. The cable end interface will probably be something other than
the familiar RJ45 connector, mainly to differentiate the Category 7 installation from existing lowerbandwidth infrastructure. Because of the higher costs associated with manufacturing and installing
these shielded products, their scope of usability is extremely limited in North America (<1%).
So, which should you use? There is quite a bit of misleading information in the industry on this subject,
the biggest myth being that Category 6 is required to run Gigabit Ethernet over copper (1000Base-T).
However, as of this writing, the TIA recommends Category 6 or Category 5e as the minimum cabling
for new network infrastructure installations.
When do I use Category 6 or 6a? Does the application standard (i.e., Gigabit Ethernet, 10G, etc.)
specify Category 6 as a minimal requirement? As of this writing, the TIA and IEEE 802.3an committee
have ratified standards for 10 Gigabit Ethernet over UTP. This standard requires an Augmented
Category 6 system to run the standard 100 meters length. The good news is that Augmented Category
6, as is the case with all TIA standards, is backward compatible and will have no trouble running
existing applications such as 10/100Base-T and 1000Base-T.
The CopperTen System is TEs version of Augmented Category 6. It provides not only support for
the transmission protocols of today, such as 10/100/1000Mbps, but also that of 10GBASE-T.
It is worth noting that the complexity of Category 6a is transparent to the end user and installer.
The products have simply been modified to overcome the shortcomings of standard Cat 6 to achieve
the desired signal to noise ratios, taking into account bundled crosstalk, to achieve all of the current
IEEE 802.3an (10GBASE-T) requirements.
Cable Type Summary
The chart below summarizes the industry standard UTP cable types used in current networking
installations.
Category
Cat 5e
Cat 6
Cat 6a
Cat 7

Test
Frequency
100MHz
250MHz
500MHz
600MHz

10/100BaseT

1000BaseT

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

10 GBASE-T
To 100m

Relative Cost

No
No
Yes
Yes

$
$$
$$$
$$$$

In addition to the UTP cabling described above, you should understand the issues of cable shielding,
and stranded versus solid cable.

11/11

Technical Reference

Augmented Category 6 is the cutting edge of UTP cabling. It is similar to Cat 6, but is characterized
to 500MHz and is also capable of running 10GBASE-T. Testing parameters are similar to that of Cat 5e
and Cat 6, with the added benefit of compliance to Alien (Bundled) Crosstalk requirements: ANEXT,
AACRF, PSANEXT and PSAACRF.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

44

Technical Reference

Choosing the Right Ethernet Patch Panels


Shielded vs. Unshielded Twisted Pair

There are actually two methods of shielding a twisted pair cable. Foiled twisted pair cable (F/UTP)
provides an overall screen or metal foil around the four pairs of conductors, but each individual twisted
pair is unshielded. Shielded twisted pair cable (S/FTP) has each individual pair shielded, plus an
overall screen around the four individually shielded pairs. The legacy token ring IBM Type 1 cable and
Category 7 are examples of STP cable. STP cable requires metal encapsulated connectors that bond
the cable shield to the telecommunications ground, in order to carry the interfering signals safely away
from the signal conducting pairs. Failure to properly connect the cable shield to ground results in the
shield coupling the interfering noise to the conductors, providing very poor transmission performance
and possibly allowing for damage to equipment and people. In fact, there is much debate whether to
ground both the ends of an STP channel, or not. Because of this and the added costs, most of the world
uses UTP cabling, with some exceptions located in a few countries in Europe.
Stranded vs. Solid Conductor Cable
Stranded cable is flexible and often used for patch panel jumpers and work area connections.
Stranded cabling is used for shorter patching applications for its flexible cable construction, but also
exhibits higher attenuation due to the smaller diameter conductors, and as such should not be used for
long, permanent installations. Solid conductor cable is used for the horizontal cable runs. The typical
gauge for Category 5e cable is 24 AWG. Category 6/6a is 23 AWGthe larger conductor diameter
improves attenuation characteristics and signal-to-noise ratio versus the smaller conductor diameter of
Category 5e.
Patch Panel Rear Termination Options
Popular choices for patch panel rear terminations include insulation displacement contact (IDC)
punchdown termination, and connectorized cable end terminations (RJ45 and RJ-21X).
Many popular data patch panels are designed using IDCs, requiring the manual punchdown termination
of each individual wire. A typical 24-port panel requires 192 individual punchdown terminations.
With this many manual terminations, installation mistakes are common, including incorrect wire mapping
(cross-wiring), opens, shorts, and excessive untwisting of the wire pairs. Terminating the horizontal
cabling room typically uses IDC punchdown panels.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

45

Technical Reference

Standard Category 5e, 6 and 6a cables contain four unshielded twisted pairs of conductors.
For 10BASE-T and 100BASE-TX applications, only two pairs are used, one for the transmit circuit
and one for receive circuit. For 1000BASE-T and 10GBASE-T all four pairs are required.

102094AE

TrueNet Structured Cabling

Unshielded twisted pair (UTP) cabling provides immunity to electromagnetic interference (EMI) with
the properties of the two conductors that make up a transmission pair being twisted together. When
UTP cabling encounters electrical interference, the noise crossing the twisted pairs is cancelled by the
twists in the cable (called Common Mode Rejection, a subject outside the scope of this discussion).

Technical Reference

Choosing the Right Ethernet Patch Panels

RJ45-to-RJ45 and RJ45-to-RJ-21X panels are


the two most popular preconnectorized systems.
The RJ-21X, also known as 50-pin telco or
25-pair Amphenol connectors, is popular because
six 4-pair Ethernet (1000BaseT) or twelve 2pair Ethernet (10/100BaseT) circuits can be
terminated at one time on a panel using the
correct multi-pair cable assembly. The main
requirement for 25-pair cable and connectors is
the PowerSum NEXT or PSNEXT requirement.

The LSA-PLUS Contact Difference

Insulation clamping ribs hold the wire


securely isolating the contact area from
vibration and mechanical stress.

Silver-plated contact tags at 45-degree


angles across the wires axis make a solid,
gas-tight connection.

Axial and torsional restoring forces make a


solid, gas-tight connection.

3
1
3
2

Effects of LSA-PLUS contact on wire:

102094AE

TrueNet Structured Cabling

For patch-panel-to-patch-panel connections


in a data center or telecommunications room,
preterminated cable assemblies and connectorized
patch panels can improve installation time and
connectivity success. A preconnectorized solution
dramatically decreases the assembly time and
increases the quality of the termination, as the
contacts points are typically gold-on-gold with
high contact forces. Preconnectorized solutions
do require up-front planningthe distances
between panels must be determined so the
correct cable assembly length can be ordered.

TE leaves more wire between contact


points; provides a more reliable stress
resistant connection.
Effects of other traditional contacts on wire:

11/11

Technical Reference

There are two predominant types of IDCs on the market today, the 110 and the LSA-PLUS 45 IDC.
Many manufacturers have now started to migrate to a 45 IDC due to its superior technical advantages,
such as lower resistance, torsional forces, better stability when vibrated and the ability to accept multiple
and stranded conductors. It is worth noting that TE still has the advantage of not only having 45 IDC,
but also using silver plating versus tin.

Typical primary wire after being


punched into a 110 IDC; positioning
contacts at a 90-degree angle results
in a weak connection, which is prone
to breakage.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

46

Technical Reference

Choosing the Right Ethernet Patch Panels


Cable Management

11/11

102094AE

Ideally, all Ethernet equipment is permanently terminated in a cross-connect field so that moves,
adds, and changes (MACs) are done using semi-permanent patch cords. This enables circuit rerouting,
upgrades for Ethernet equipment, and routine maintenance with less downtimeand less chance
for damaging active equipment ports and cables.
At a minimum, the Ethernet network should include the following characteristics:
Access to cables. Especially as rack density increases, it is important that cables can be easily
identified and traced for MACs. Otherwise, simple rearrangements turn into hours of technician
time and downtime.
Cable routing. Establishing defined cable routing paths within racks, between racks, and between
equipment rooms ensures that patch cords and cables remain organized and neat. This increases
both the service life of cables and the availability of Ethernet services for users.
Physical protection and storage. Cables dangling from overhead or laying the floor invite problems.
The proper method is to provide storage within each rack so that inadvertent damage and downtime
is avoided.
TE Solutions
Listed below are some of TEs panel solutions that meet the recommendations given above. Please
contact TEs Technical Assistance Center for more information on these or any other solutions.

Catalog
Number

Category

TEPP24505
TEPP24606
TEPP245800BTEL
TEPP245100TEL
6653 1 585-24
6653 1 585-48
PP24AC5ET
PP48AC5ET
6653 1 587-24
6653 1 587-48
6653 1 677-24
6653 1 677-48
6653 1 679-24
6653 1 679-48
PP24AC6T
PP48AC6T
TPNP-24NC10-BK
TPNP-24APC10-BK

www.te.com/adc

5e
6
5e
5
5e
5e
5e
5e
5e
5e
6
6
6
6
6
6
6a
6a

Wiring
Scheme
Universal T568A/B
Universal T568A/B
T568B
10/100Base-T Specific
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B
Universal T568A/B

+1-952-938-8080

Rear
Termination

Applications
Supported

RJ45
RJ45
RJ21X
RJ21X
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC
RJ45 LSA-PLUS IDC

All except for 10 Gigabit


All except for 10 Gigabit
All except for 10 Gigabit
10/100Base-T
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All except for 10 Gigabit
All
All

1-800-366-3891

47

Technical Reference

TrueNet Structured Cabling

Of course, youll never achieve zero bit errors or 500MHz from your 6a Ethernet system if cables are
difficult to manage and easily damaged. Careful attention should be paid to the cable management
scheme that surrounds patch panels and Ethernet equipment.

Technical Reference

Key Fiber Optic Cable Management Concepts


Proper cable management practices make fiber networks less susceptible to accidental damage, quicker
to install, less expensive to own and operate over the long haul and easier to expand as needs grow.

TrueNet Structured Cabling


102094AE

Bend radius: At turns in fiber runs, maintain a 1.5-inch bend radius. Tighter bends may cause
macro-bending of individual fibers that allow light to escape the signal path, resulting in signal
attenuation. More severe bends can break fiber strands completely, resulting in signal loss.
Cable troughing: Used to route fiber optic cable, troughing systems provide a protected pathway
for fiber to traverse spans between rooms and equipment racks. Good troughing systems will keep
fiber separate from copper cable, protect it from out-of-tolerance bends and promote neat, easily
accessible runs.
Vertical cable protection: Allowing fiber to hang unprotected from the back of equipment can
be a recipe for disaster. Exposed cables are easy to snag accidentally with a hand or foot, which can
result in damage to the connector or fiber itself. Additionally, over time the weight of hanging fiber
can cause bends outside the acceptable limit and consequently, damage to the fiber. Proper vertical
cable management in panels or equipment bays provides adequate support, cable protection and
a transition from the vertical run to the back of the equipment that does not damage the fiber.
Cable pile-up: In horizontal fiber runs, it is unacceptable to allow a pile of fiber cable to exceed two
inches. Beyond that point, the weight of the bundle will surpass the crush tolerance limit of the fiber
at the bottom of the stack, resulting in microscopic damage and signal attenuation.
Cable segregation: Keep fiber runs separate from legacy copper cable. Copper cable is relatively
heavy and can crush fiber cables. Additionally, segregating coax from fiber ensures that technicians
repairing coax do not accidentally damage the fiber cable while working on the copper.
Labeling: As you would in a legacy copper environment, develop good labeling practices. Know
where fibers originate and terminate. Doing so will reduce maintenance time and the likelihood that
a maintenance tech will make hasty decisions on fiber routing that can lead to a rats nest of cable
and patch cords.
Density: When selecting products for a fiber network, remember future maintenance. The more
densely connectors are packed onto a panel, the more difficult it will be for even the most dexterous
technicians to maintain. Remember, inevitably cables will be moved, so the ability to trace and re-route
them is critical to working efficiently.
Future proofing: When planning rack configurations with a given number of terminations to
accommodate a relatively low number of fibers for todays requirements, dont forget the future.
A fiber path that easily supports 12 fibers today may be inadequate to support the 200 fibers needed
in a few years. Planning up front for the future can save the expense of ripping out outgrown
capacity down the road.
Proper cable management is extremely important to the success of an evolving high-performance
communications network. The fact that a single fiber may transmit mission-critical signals underlies the
importance of taking the steps necessary to manage fibers installation and use.

11/11

Technical Reference

Key cable management concepts include:

www.te.com/adc

+1-952-938-8080

1-800-366-3891

48

Technical Reference

Key Fiber Optic Cable Management Concepts


Singlemode versus Multimode Fiber

11/11

102094AE

Multimode fiber optic cable carries multiple light rays with different reflection angles within the fiber
core. With a fiber core thats thicker than singlemode fiber, multimode cable is better suited for short
runs, such as those between equipment and panels. Multimode should be used to connect devices
such as optical routers and servers.
Fiber optic cable offers a level of security that exceeds copper or microwave transmission
because it is difficult to tap without breaking.
Ultra Physical Contact Connectors and Angled Physical Contact Connectors
Attaching a connector to a fiber optic cable will cause some of the light traversing that fiber to be
lost. Regardless of whether the connector was installed in the factory or the field, its presence will be
responsible for some light being reflected back towards its source, the laser. Commonly known as return
loss (RL), these reflections can damage the laser and degrade the signals performance. The degree
of signal degradation caused by RL depends on the lasers specifications; some lasers are more sensitive
to RL than others.
The amount of optical return loss generated is related to the type of polish that is used
on the connector.
The angled physical contact (APC) connector is best for high bandwidth applications and long haul
links since it offers the lowest return loss characteristics of connectors currently available. In an APC
connector, the endface of a termination is polished precisely at an 8-degree angle to the fiber cladding
so that most RL is reflected into the cladding where it cannot interfere with the transmitted signal or
damage the laser source. As a result, APC connectors offer a superior RL performance of -65dB.
However, it is extremely difficult to field terminate an angled physical contact connector at 8 degrees
with any consistent level of success. Therefore, if an APC connector is damaged in the field it should
be replaced with a factory-terminated APC connector.
The ultra physical contact (UPC) connectorwhile not offering the superior optical return loss
performance of an APC connectorhas RL characteristics that are acceptable for data transmissions.
When using UPC connectors, make sure your lasers specifications can handle the return loss your
UPC connectors will generate.
Offering 57dB RL, ultra physical contact connectors rely on machine polishing to deliver their low
optical return loss characteristics. Ultra physical contact polishing refers to the radius of the endface
polishing administered to the ferrule, the precision tube used to hold a fiber in place for alignment.
The rounded finish created during the polishing process allows fibers to touch on a high point near the
fiber core where light travels. Unlike APC connectors, UPC connectors can, with the proper tools and
training, be repaired in the field.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

49

Technical Reference

TrueNet Structured Cabling

Fiber optic cable comes in two varieties: singlemode and multimode. Both have applications in
structured cabling applications. Singlemode fiber optic cables transmit a single ray of light used to carry
modulated signals. It is normally used in applications requiring the transmission of signals over a long
distance, for example, between separate facilities on a campus.

Technical Reference

Key Fiber Optic Cable Management Concepts


Connector Styles
SC: The SC style offers excellent loss characteristics and comes in a standard footprint. It is easy to
snap in and remove. The SC is pull-proof and is available in UPC and APC.

Duplex SC: Offers the same features as the SC style but supports two-way communication.
When designing a fiber network for routing signals through a facility, standardizing on a single
connector type will make network repairs and technician training faster and less expensive. However,
despite efforts to standardize on a single connector style, it may be necessary to use a hybrid cable in
some applications.

102094AE

TrueNet Structured Cabling

ST: Very similar in appearance to a BNC connector, the ST is a screw-on type connector. It does
not offer the pull-proof resiliency of SC and LC connectors. ST connectors, which are made of metal
components, are only available with UPC polishing. In recent years, the popularity of ST connectors
has waned as the use of SC and LC connectors has grown.

11/11

Technical Reference

LC: The most popular of all connectors, the LC is a small-form-factor connector. The LC features are
similar to SC, but its size allows double the density. Available in UPC and APC.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

50

CopperTen Augmented Category 6 Horizontal Cable ..... 53


CopperTen Augmented Category 6 F/UTP
Horizontal Cable .............................................................. 55
Category 6 Horizontal Cable ............................................ 61
Category 6 Limited Combustible Cable ............................ 73
Category 6 Outdoor Cable .............................................. 76
Category 5e Horizontal Cable .......................................... 79
Category 5e Outdoor Cable ............................................. 88
Category 5e Backbone Cable ........................................... 90
Category 3 Horizontal and Backbone Cable ..................... 94
Category 1 Horizontal and Backbone Cable ..................... 98

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

51

Copper Cable Solutions

Introduction ..................................................................... 52

102094AE

TrueNet Structured Cabling

Copper Cable Solutions

Copper Cable Solutions


Introduction

TrueNet Structured Cabling

TE offers a wide variety of copper cable for transmission of the most critical
data transmissions. The cable portfolio includes CopperTen Augmented
Category 6 cable for the 10 Gpbs Ethernet over UTP standard, as well as
standards-compliant cable for Category 3, Category 5, Category 5e and
Category 6 applications. Our high performance copper riser and Plenum
data cables for backbone and horizontal applications are produced by highly
automated manufacturing processes that ensure consistent quality and
dependability with superior electrical performance.
TEs patented AirES (Air Enhanced System) is the cable technology that
improves data thoughput, saves space, eases installation and reduces the
danger of fire and smoke. Through a unique design and advanced manufacturing techniques we are
able to build AirES cable using air as a conductor insulator. This groundbreaking process results in a
cable that incorporates superior performance while reducing overall size up to 32 percent.
CopperTen Augmented Category 6 Cable with AirES Technology
The worlds first UTP structured cable to enable 10 gigabit Ethernet transmission over a full
100 meters
Patented inside out filler provides the necessary air pockets to minimize alien crosstalk between
cables in a bundle
Rotates along its length
Creates a large air footprint
Generates more separation between cables
Unsurpassed electrical performance parameters
Increased signal to noise ratio (ACR) through performance increase in crosstalk and attenuation
Decreased crosstalk through reduced capacitive effects, with the introduction of air as
an insulator
Increased signal strength through less attenuation (Insertion Loss), a by-product of reduced
dielectric loss and twist rate
TrueNet Category 6 and Category 5e Cables with AirES Technology
Improved physical and mechanical design attributes

102094AE

Increased signal speed and strength

11/11

Copper Cable Solutions

TrueNet Structured Cabling System With AirES Technology

Unsurpassed electrical performance parameters


Increased signal to noise ratio (ACR) through performance increase in crosstalk and attenuation
Decreased crosstalk through reduced capacitive effects, with the introduction of air as
an insulator
Increased signal strength through less attenuation (Insertion Loss), a by-product of reduced
dielectric loss and twist rate
Cross-sectional area reduction of 28 percent for TrueNet Category 5e and 32 percent for TrueNet
Category 6 provide multiple benefits
Increases fill rates by an average of 28 to 32 percent, decreasing installation costs
Increases fill rates
Decreases access-way space required
Improves safety in event of fire due to decrease of 32 percent in amount of fuel present
Provides four times greater crush resistance compared to UL 444 requirements
Decreases installation time
Allows more cables to be pulled at the same time
Promotes faster terminations

www.te.com/adc

+1-952-938-8080

1-800-366-3891

52

Copper Cable Solutions

CopperTen Augmented Category 6 Horizontal Cable


CopperTen Category 6a Plenum Data Cable

Unique oblique elliptical offset filler


for improved alien crosstalk
Features AirES technology
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)

Ordering Information

100Mbps TP-PMD
Broadband and baseband video

Description

100Base-T (Fast Ethernet)

4-pair Plenum data cable

100Base-T4 (Fast Ethernet)

1000' reel

Catalog Number*
10G-A6TP-XX02

100Base-TX (Fast Ethernet)


100VG-Any LAN (IEEE 802.12)

Additional packaging options are available, please


contact TE Technical Assistance Center.

52/155Mbps ATM (ATM Forum)


622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)

*To order jacket color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red

1.2Gbps ATM (ATM Forum)


77 Channel broadband video
10GBase-T Ethernet (IEEE 802.3an)

Compliances
UL Subject 444

11/11

102094AE

(UL)-C(UL) Type CMP


ICEA S-90-661
NEC 800 Type CMP
TIA/EIA 568-B.2-10 Standards
ISO/IEC 11801 Class EA Horizontal Cable
Requirements

Specifications
Conductor:
Insulation:
Separator:
Jacket:
Nominal outer diameter:
Maximum average outer diameter:

www.te.com/adc

23 AWG solid bare copper


All 4 pairs 100% FEP
Fluoropolymer
Non-lead, flame retardant PVC
0.275" (7.0mm)
0.275" (7.0mm)

+1-952-938-8080

1-800-366-3891

53

Copper Cable Solutions

TrueNet Structured Cabling

Features

Copper Cable Solutions

CopperTen Augmented Category 6 Horizontal Cable


CopperTen Category 6a Riser Data Cable

TrueNet Structured Cabling

Unique oblique elliptical offset filler


for improved alien crosstalk
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)
100Mbps TP-PMD

Ordering Information

Broadband and baseband video


100Base-T (Fast Ethernet)

Description

100Base-T4 (Fast Ethernet)

Catalog Number*

4-pair riser data cable

100Base-TX (Fast Ethernet)

1000' reel

100VG-Any LAN (IEEE 802.12)


52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
1.2Gbps ATM (ATM Forum)

10G-A6TR-XX02

Additional packaging options are available, please


contact TE Technical Assistance Center.
*To order jacket color, replace XX with:
BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red

77 Channel broadband video


10GBase-T Ethernet (IEEE 802.3an)

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG

102094AE

ICEA S-90-661

11/11

Copper Cable Solutions

Features

NEC 800 Type CMR


TIA/EIA 568-B.2-10 Standards
ISO/IEC 11801 Class EA Horizontal Cable
Requirements
Fire load: 822kJ/m (0.23kWh/m)

Specifications
Conductor:
Insulation:
Separator:
Jacket:
Nominal outer diameter:
Maximum average outer
diameter:

www.te.com/adc

23 AWG solid bare copper


100% Polyolefin
Flame retardant polyolefin
Non-lead, flame retardant PVC
0.295" (7.5mm)
0.295" (7.5mm)

+1-952-938-8080

1-800-366-3891

54

Copper Cable Solutions

CopperTen Augmented Category 6 F/UTP Horizontal Cable

11/11

102094AE

TE F/UTP CopperTen cable can be used in data


center, communications closet and work station
for 10G shielded performance. Installed in highperformance networks world wide, the systems
design minimizes alien crosstalk and insertion loss and
meets the performance requirements of IEEE 802.3an
and TIA 568-B.2-10 standards.
Features

Common Applications

Supports 10 Gigabit Ethernet over shielded


copper to a full 100 meters

4/16 Mb/s Token Ring (IEEE 802.5)

20 year TrueNet CopperTen warranty

100 Mb/s TP-PMD

Compliances

Broadband & Baseband Video

10BASE-T (IEEE 802.3)

Copper Cable Solutions

TrueNet Structured Cabling

CopperTen Four Pair F/UTP Plenum Cable

100BASE-T (Fast Ethernet)

UL Subject 444

100BASE-T4 (Fast Ethernet)

(UL)-C(UL) Type CMP

100BASE-TX (Fast Ethernet)

ICEA S-90-661

100VG-Any LAN (IEEE 802.12)

NEC 800 Type CMP

52/155 Mb/s ATM (ATM Forum)

TIA/EIA-568-B.2-1 Category 6 Horizontal


Cable Requirements

622 Mb/s ATM (ATM Forum)


1000BASE-T (Gigabit Ethernet)

ETL Verified TIA/EIA-568-B.2-10 Augmented


Category 6 Horizontal Cable Requirements

1 Gigabit Networking System (WGNA)

ISO/IEC 11801 Category 6 Horizontal Cable


Requirements

1.2 Gb/s ATM (ATM Forum)

ISO/IEC 11801 Category 6a Horizontal Cable


Requirements

10GBASE-T Ethernet (IEEE P802.3an)

77 Channel Broadband Video

Specifications
CONSTRUCTION
Conductor:
Insulation:
Separator:
Shield:
Drain Wire:
Jacket:
Nominal O.D.:

23 AWG solid bare copper


Foamed FEP
Fluoropolymer
Aluminum/polyester foil
Stranded tinnned copper
Lead-free, flame retardant PVC
285" (7.2mm)

THERMAL CHARACTERISTICS
Transport and Storage:
Installation:
Operation:

-10C to 60C
4C to 50C
-10C to 60C

MECHANICAL CHARACTERISTICS
Bend Radius
During Installation:
Installed:
Pull Tension:

16 X O.D.
8 X O.D.
25 lb/f (110N)

ELECTRICAL CHARACTERISTICS
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


5%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
72%

www.te.com/adc

+1-952-938-8080

1-800-366-3891

55

Copper Cable Solutions

CopperTen Augmented Category 6 F/UTP Horizontal Cable

Fitted
Impedance

MHZ

Ohms

Insertion Loss
dB/100m

Return Loss

Pair-Pair NEXT

dB/100m

PSNEXT

dB/100m

dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

Min

Spec

100 +/- 15

1.7

24.3

20

85.9

74.3

83.2

72.3

100 +/- 15

3.4

3.7

27.1

23

75.9

65.3

73

63.3

100 +/- 15

4.8

5.2

29.4

24.5

68.6

60.8

65.4

58.8

10

100 +/- 15

5.4

5.9

31

25

61.5

59.3

59.1

57.3

16

100 +/- 15

6.8

7.4

30.4

25

63.6

56.2

62.7

54.2

20

100 +/- 15

7.6

8.3

31.6

25

65.4

54.8

62.7

52.8

25

100 +/- 15

8.6

9.3

33.1

24.3

62.6

53.3

58.6

51.3

31.25

100 +/- 15

9.7

10.4

34.2

23.6

67.1

51.9

63.5

49.9

62.5

100 +/- 15

13.9

14.9

31.1

21.5

54

47.4

52.5

45.4

100

100 +/- 15

17.9

19

28.9

20.1

52.7

44.3

50.7

42.3

155

100 +/- 15

22.6

24

33

18.8

45.3

41.4

44.7

39.4

200

100 +/- 15

26.1

27.5

23.5

18

50.7

39.8

48.7

37.8

250

100 +/- 15

29.4

31

22.9

17.3

42.3

38.3

41.1

36.3

300

100 +/- 15

32.7

34.2

26.2

16.8

43.1

37.1

40.5

35.1

350

100 +/- 15

35.8

37.2

22.9

16.3

45.2

36.1

42.2

34.1

400

100 +/- 15

38.7

40

21.9

15.9

44.7

35.3

41.4

33.3

450

100 +/- 15

41.5

42.7

22.4

15.5

39.2

34.5

37.8

32.5

500

100 +/- 15

44.1

45.3

20.1

15.2

36.7

33.8

35.2

31.8

550

100 +/- 15

46.9

21.7

39.9

38.6

600

100 +/- 15

49.5

17

36.6

34.4

102094AE

TrueNet Structured Cabling

FREQ

11/11

Copper Cable Solutions

CopperTen Four Pair F/UTP Plenum Cable

www.te.com/adc

+1-952-938-8080

1-800-366-3891

56

Copper Cable Solutions

CopperTen Augmented Category 6 F/UTP Horizontal Cable

11/11

102094AE

FREQ

Pair-Pair ACR

PSACR

Pair-Pair ELFEXT

PSNEXT

MHZ

dB/100m

dB/100m

dB/100m

dB/100m

TCL

Max

Spec

Min

Spec

Min

Spec

Min

Spec

Spec

84.2

72.3

81.5

70.3

83.8

67.8

83.1

64.8

40.0

72.7

61.5

69.8

59.5

75.8

55.8

75.2

52.8

40.0

64.1

55.5

60.9

53.5

64.2

49.7

62.5

46.7

40.0

10

56.5

53.4

54.0

51.4

64.0

47.8

60.3

44.8

40.0

16

57.2

48.8

56.3

46.8

63.7

43.7

61.2

40.7

38.0

20

58.1

46.5

55.1

44.5

59.9

41.8

58.4

38.8

37.0

25

54.4

44.0

50.4

42.0

57.5

39.8

56.9

36.8

36.0

31.25

57.5

41.5

53.8

39.5

55.4

37.9

55.6

34.9

35.1

62.5

40.8

32.5

39.3

30.5

52.4

31.9

50.6

28.9

32.0

100

35.7

25.3

33.4

23.3

52.9

27.8

51.1

24.8

30.0

155

23.7

17.5

22.1

15.5

45.4

24.0

43.8

21.0

28.1

200

25.8

12.3

23.8

10.3

46.0

21.8

43.4

18.8

27.0

250

14.2

7.4

12.5

5.4

43.0

19.8

41.0

16.8

26.0

300

11.9

3.0

9.3

1.0

43.0

18.3

39.3

15.3

350

11.0

-1.0

8.1

-3.0

39.0

16.9

38.3

13.9

400

7.5

-4.7

3.4

-6.7

37.5

15.8

35.7

12.8

450

-0.7

-8.2

-2.2

-10.2

38.9

14.7

36.2

11.7

500

-5.7

-11.4

-7.2

-13.4

39.5

13.8

35.4

10.8

550

-5.6

-6.9

31.9

32.3

600

-12.9

-14.4

31.2

29.2

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA-568-B.2-10 specification.

Ordering Information
Description

Catalog Number

1000 foot reel, 42lbs 62kg

10G-A6TPF-XX02

NOTES: XX = Jacket color - BL = Blue, WT = White, GY = Gray

www.te.com/adc

+1-952-938-8080

1-800-366-3891

57

Copper Cable Solutions

TrueNet Structured Cabling

CopperTen Four Pair F/UTP Plenum Cable

Copper Cable Solutions

CopperTen Augmented Category 6 F/UTP Horizontal Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

CopperTen Four Pair F/UTP Riser Cable


TE F/UTP CopperTen cable can be used in data center,
communications closet and work station for 10G
shielded performance. Installed in high-performance
networks world wide, the systems design minimizes
alien crosstalk and insertion loss and meets the
performance requirements of IEEE 802.3an and TIA
568-B.2-10 standards.
Features

Common Applications

Supports 10 Gigabit Ethernet over shielded


copper to a full 100 meters

4/16 Mb/s Token Ring (IEEE 802.5)

20 year TrueNet CopperTen warranty

100 Mb/s TP-PMD

Compliances

Broadband & Baseband Video

10BASE-T (IEEE 802.3)

100BASE-T (Fast Ethernet)

UL Subject 444

100BASE-T4 (Fast Ethernet)

(UL)-C(UL) Type CMR

100BASE-TX (Fast Ethernet)

ICEA S-90-661

100VG-Any LAN (IEEE 802.12)

NEC 800 Type CMR

52/155 Mb/s ATM (ATM Forum)

TIA/EIA-568-B.2-1 Category 6 Horizontal


Cable Requirements

622 Mb/s ATM (ATM Forum)


1000BASE-T (Gigabit Ethernet)

ETL Verified TIA/EIA-568-B.2-10 Augmented


Category 6 Horizontal Cable Requirements

1 Gigabit Networking System (WGNA)

ISO/IEC 11801 Category 6 Horizontal Cable


Requirements

1.2 Gb/s ATM (ATM Forum)

ISO/IEC 11801 Category 6a Horizontal Cable


Requirements

10GBASE-T Ethernet (IEEE P802.3an)

77 Channel Broadband Video

Specifications
CONSTRUCTION
Conductor:
Insulation:
Separator:
Shield:
Drain Wire:
Jacket:
Nominal O.D.:

23 AWG solid bare copper


HDPE
HDPE
Aluminum/polyester foil
Stranded tinnned copper
Lead-free, flame retardant PVC
.280" (7.1mm)

THERMAL CHARACTERISTICS
Transport and Storage:
Installation:
Operation:

-10C to 60C
4C to 50C
-10C to 60C

MECHANICAL CHARACTERISTICS
Bend Radius
During Installation:
Installed:
Pull Tension:

16 X O.D.
8 X O.D.
25 lb/f (110N)

ELECTRICAL CHARACTERISTICS
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


5%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
72%

www.te.com/adc

+1-952-938-8080

1-800-366-3891

58

Copper Cable Solutions

CopperTen Augmented Category 6 F/UTP Horizontal Cable

Fitted
Impedance

MHZ

Ohms

Insertion Loss
dB/100m

Return Loss

Pair-Pair NEXT

dB/100m

dB/100m

PSNEXT
dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

Min

Spec

100 +/- 15

1.7

2.0

24.3

20.0

85.9

74.3

83.2

72.3

100 +/- 15

3.4

3.7

27.1

23.0

75.9

65.3

73.0

63.3

100 +/- 15

4.8

5.2

29.4

24.5

68.6

60.8

65.4

58.8

10

100 +/- 15

5.4

5.9

31.0

25.0

61.5

59.3

59.1

57.3

16

100 +/- 15

6.8

7.4

30.4

25.0

63.6

56.2

62.7

54.2

20

100 +/- 15

7.6

8.3

31.6

25.0

65.4

54.8

62.7

52.8

25

100 +/- 15

8.6

9.3

33.1

24.3

62.6

53.3

58.6

51.3

31.25

100 +/- 15

9.7

10.4

34.2

23.6

67.1

51.9

63.5

49.9

62.5

100 +/- 15

13.9

14.9

31.1

21.5

54.0

47.4

52.5

45.4

100

100 +/- 15

17.9

19.0

28.9

20.1

52.7

44.3

50.7

42.3

155

100 +/- 15

22.6

24.0

33.0

18.8

45.3

41.4

44.7

39.4

200

100 +/- 15

26.1

27.5

23.5

18.0

50.7

39.8

48.7

37.8

250

100 +/- 15

29.4

31.0

22.9

17.3

42.3

38.3

41.1

36.3

300

100 +/- 15

32.7

34.2

26.2

16.8

43.1

37.1

40.5

35.1

350

100 +/- 15

35.8

37.2

22.9

16.3

45.2

36.1

42.2

34.1

400

100 +/- 15

38.7

40.0

21.9

15.9

44.7

35.3

41.4

33.3

450

100 +/- 15

41.5

42.7

22.4

15.5

39.2

34.5

37.8

32.5

500

100 +/- 15

44.1

45.3

20.1

15.2

36.7

33.8

35.2

31.8

550

100 +/- 15

46.9

21.7

39.9

38.6

600

100 +/- 15

49.5

17.0

36.6

34.4

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

59

Copper Cable Solutions

FREQ

102094AE

TrueNet Structured Cabling

CopperTen Four Pair F/UTP Riser Cable

Copper Cable Solutions

CopperTen Augmented Category 6 F/UTP Horizontal Cable

TrueNet Structured Cabling


102094AE

FREQ

Pair-Pair ACR

PSACR

Pair-Pair ELFEXT

PSNEXT

MHZ

dB/100m

dB/100m

dB/100m

dB/100m

TCL

Max

Spec

Min

Spec

Min

Spec

Min

Spec

Spec

84.2

72.3

81.5

70.3

83.8

67.8

83.1

64.8

40.0

72.7

61.5

69.8

59.5

75.8

55.8

75.2

52.8

40.0

64.1

55.5

60.9

53.5

64.2

49.7

62.5

46.7

40.0

10

56.5

53.4

54.0

51.4

64.0

47.8

60.3

44.8

40.0

16

57.2

48.8

56.3

46.8

63.7

43.7

61.2

40.7

38.0

20

58.1

46.5

55.1

44.5

59.9

41.8

58.4

38.8

37.0

25

54.4

44.0

50.4

42.0

57.5

39.8

56.9

36.8

36.0

31.25

57.5

41.5

53.8

39.5

55.4

37.9

55.6

34.9

35.1

62.5

40.8

32.5

39.3

30.5

52.4

31.9

50.6

28.9

32.0

100

35.7

25.3

33.4

23.3

52.9

27.8

51.1

24.8

30.0

155

23.7

17.5

22.1

15.5

45.4

24.0

43.8

21.0

28.1

200

25.8

12.3

23.8

10.3

46.0

21.8

43.4

18.8

27.0

250

14.2

7.4

12.5

5.4

43.0

19.8

41.0

16.8

26.0

300

11.9

3.0

9.3

1.0

43.0

18.3

39.3

15.3

350

11.0

-1.0

8.1

-3.0

39.0

16.9

38.3

13.9

400

7.5

-4.7

3.4

-6.7

37.5

15.8

35.7

12.8

450

-0.7

-8.2

-2.2

-10.2

38.9

14.7

36.2

11.7

500

-5.7

-11.4

-7.2

-13.4

39.5

13.8

35.4

10.8

550

-5.6

-6.9

31.9

32.3

600

-12.9

-14.4

31.2

29.2

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA-568-B.2-10 specification.

Ordering Information
Description

Catalog Number

1000 foot reel, 41lbs 61kg

10G-A6TRF-XX02

NOTES: XX = Jacket color - BL = Blue, WT = White, GY = Gray

11/11

Copper Cable Solutions

CopperTen Four Pair F/UTP Riser Cable

www.te.com/adc

+1-952-938-8080

1-800-366-3891

60

Copper Cable Solutions


Category 6 Horizontal Cable
Category 6 Plenum Cable

TrueNet Category 6 Plenum cable


is protected by US Patents 6153826

TrueNet Category 6 Plenum cable


is also available in a side-by-side configuration

Common Applications

Compliances

4/16Mbps Token Ring (IEEE 802.5)

UL Subject 444

10Base-T (IEEE 802.3)

(UL)-C(UL) Type CMP

100Mbps TP-PMD

ICEA S-90-661

Broadband and baseband video

NEC 800 Type CMP

100Base-T (Fast Ethernet)

ISO/IEC 11801 Class E

100Base-T4 (Fast Ethernet)

TIA/EIA-568-B.2-1 Category 6 horizontal


cable requirements

100Base-TX (Fast Ethernet)

Copper Cable Solutions

TrueNet Structured Cabling

100VG-AnyLAN (IEEE 802.12)


52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)
1.2Gbps ATM (ATM Forum)

11/11

102094AE

77 Channel broadband video

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Pairing:
Filler:
Color-coding:
Jacket:

24 AWG solid bare copper


100% FEP
Short, staggered pair lays
Fluoropolymer
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

61

Copper Cable Solutions


Category 6 Horizontal Cable
Category 6 Plenum Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
FITTED
FREQ IMPEDANCE
(MHz)
(Ohms)
SPEC
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550
FREQ
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

5
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
25 nS/100 meters @100MHz
75%

INSERTION LOSS
(dB/100m)

RETURN LOSS
(dB/100m)

Max

TIA Spec

Min

TIA Spec

Min

TIA Spec

Min

TIA Spec

1.7
3.4
4.9
5.5
7.0
7.9
8.9
9.9
14.3
18.4
23.3
26.8
30.4
33.7
36.7
39.6
42.5
45.3
47.7

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

28.5
32.1
35.0
34.6
31.7
32.1
36.5
36.7
34.0
30.8
27.3
31.0
28.6
27.2
24.3
25.0
24.5
24.2
18.6

20.0
22.9
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

83.8
74.9
74.4
70.3
67.2
66.8
65.6
61.8
61.0
60.2
54.8
54.9
49.5
49.0
46.3
47.5
47.3
43.8
40.2

74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
41.4
39.8
38.3

81.9
74.3
71.0
68.0
66.7
64.7
63.6
60.9
59.3
57.4
51.4
52.4
48.5
48.2
44.8
45.2
43.4
43.0
39.4

72.3
63.3
58.8
57.3
54.2
52.8
51.3
49.9
45.4
42.3
39.4
37.8
36.3

Pair-Pair ACR
(dB/100m)

PSACR
(dB/100m)

Min

TIA Spec

Min

TIA Spec

86.8
71.7
69.8
65.1
64.8
59.4
60.2
52.5
49.3
42.7
33.2
30.3
26.7
19.4
16.8
12.0
10.4
8.8
1.7

72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

84.2
71.2
66.4
62.8
61.5
57.4
57.7
51.3
47.9
41.6
29.9
26.9
22.2
16.6
14.7
10.2
8.4
4.8
0.7

70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

Pair-Pair NEXT
(dB/100m)

Pair-Pair ELFEXT
(dB/100m)
Min

TIA Spec

73.6
62.7
57.2
55.2
51.1
49.3
47.4
45.5
40.1
36.8
33.6
31.7
29.1
26.2
21.3
22.1
28.3
23.6
25.7

67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
24.0
21.8
19.8

PSNEXT
(dB/100m)

PSELFEXT
(dB/100m)
Min
72.6
61.8
56.2
54.2
49.8
48.2
46.5
44.4
39.4
35.9
33.2
30.6
28.9
25.5
21.8
22.5
27.3
24.0
24.7

LCL
(dB/100m)

TIA Spec

Min

64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
21.0
18.8
16.8

40.0
40.0
40.0
40.0
38.0
37.0
36.0
35.1
32.0
30.0
28.1
27.0
26.0

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

62

Copper Cable Solutions


Category 6 Horizontal Cable
Category 6 Plenum Cable
Ordering Information
Weight (Lbs/kft)

Catalog Number*

4-pair cable
Nominal OD: 0.208" (5.28mm)
Maximum OD: 0.212" (5.38mm)
Reel packaging1000'

30

TN6SP-XX02

Reel in a box1000'

32

TN6SP-XXRB

4-pair side-by-side cable


Nominal OD: 0.22" x 0.45" (5.6mm x 11.43mm)

76

TN6SPX2-XXYY

*To order cable sheath color, replace XX with:

Copper Cable Solutions

BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
*Other reel sizes available, please contact TE Customer Services.

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

63

Copper Cable Solutions


Category 6 Horizontal Cable
Category 6 Riser Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)

TrueNet Category 6 riser cable is protected


by US Patents 6153826 and 6150612

100Base-TX (Fast Ethernet)


100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)
1.2Gbps ATM (ATM Forum)
77 Channel broadband video)

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR
ISO/IEC 11801 Category 6
ETL Verified TIA/EIA-568-B.2-1 Category 6
horizontal cable requirements

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Filler:
Color-coding:
Jacket:

24 AWG solid bare copper


100% Polyolefin
Short, staggered pair lays
polyolefin
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

64

Copper Cable Solutions


Category 6 Horizontal Cable
Category 6 Riser Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

FREQ
(MHz)

FITTED
IMPEDANCE
(Ohms)
SPEC

Max

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550

100 5
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3

1.8
3.6
5.1
5.8
7.4
8.3
9.3
10.4
14.9
19.0
24.0
27.4
30.8
33.9
36.6
39.4
42.3
44.8
47.1

FREQ
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550

INSERTION
LOSS
(dB/100m)

Pair-Pair ACR
(dB/100m)
Min
81.8
74.4
60.6
61.6
63.5
54.3
53.4
52.0
42.2
37.0
29.0
23.3
19.8
10.8
9.8
5.9
6.7

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
25 nS/100 meters @100MHz
69%

TIA
Spec
72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

RETURN LOSS
(dB/100m)

Pair-Pair NEXT
(dB/100m)

TIA Spec

Min

TIA Spec

Min

TIA Spec

Min

TIA Spec

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

27.2
32.2
34.2
33.8
33.9
30.6
33.1
32.9
33.5
29.4
23.5
27.1
27.9
23.3
21.5
22.1
20.4
18.5
18.3

20.0
22.9
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

83.4
76.9
65.6
67.2
65.9
62.2
60.1
60.6
54.0
54.4
52.2
49.9
50.1
44.1
45.9
44.8
45.8
41.6
41.1

74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
41.4
39.8
38.3

81.0
73.7
64.0
65.7
63.8
61.1
59.9
58.5
53.1
52.3
50.5
47.6
47.7
42.6
45.2
41.9
42.5
40.0
38.8

72.3
63.3
58.8
57.3
54.2
52.8
51.3
49.9
45.4
42.3
39.4
37.8
36.3

PSACR
(dB/100m)
Min
79.3
72.9
59.2
60.1
60.3
53.2
51.9
51.8
41.4
35.9
27.2
21.0
17.4
9.2
9.1
4.8
3.7

TIA
Spec
70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

Pair-Pair ELFEXT
(dB/100m)
Min

TIA
Spec

75.4
63.0
56.0
54.7
50.4
49.8
47.3
46.0
40.3
37.2
35.2
35.7
32.1
27.0
24.9
23.7
22.3
19.9
15.4

PSELFEXT
(dB/100m)
Min
74.8
62.5
55.6
54.7
50.5
49.8
47.1
45.9
40.3
37.1
34.6
32.0
31.5
25.5
23.8
21.2
19.5
18.7
15.4

67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
24.0
21.8
19.8

TIA
Spec
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
21.0
18.8
16.8

PSNEXT
(dB/100m)

LCL
(dB/100m)

ISO
SPEC

TIA
Spec

ELTCTL Min
(dB)

40.0
40.0
40.0
40.0
38.0
37.0
36.0
35.1
32.0
30.0
28.1
27.1
26.0

35.0
23.0
16.9
15.0
10.9
9.0
7.0
5.1

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

65

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions


Category 6 Horizontal Cable
Category 6 Riser Cable
Ordering Information
Catalog Number*

4-pair cable, CMR flame rated


Nominal OD: 0.206" (5.4mm)
Reel packaging1000'

26

TN6SR-XX02

Reel in a box1000'

28

TN6SR-XXRB

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
*Other reel sizes available, please contact TE Customer Services.

102094AE

TrueNet Structured Cabling

Weight (Lbs/kft)

11/11

Copper Cable Solutions

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

66

Copper Cable Solutions


Category 6 Horizontal Cable

Category 6 Bundled Plenum Cable

Individual 4-pair horizontal cables twisted and


bound together with Kevlar cord
Patented impedance matching for zero-bit
errors
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)

Copper Cable Solutions

TrueNet Structured Cabling

Features

100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Compliances
UL Subject 444
(UL)-C(UL) Type CMP
ICEA S-90-661

11/11

102094AE

NEC 800 Type CMP


ISO/IEC 11801 Class D
TIA/EIA-568-B.2-1 Category 6 horizontal,
individual cables

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Individual cable diameter:
Jacket:

24 AWG solid bare copper


100% FEP
0.208" (5.28mm)
Non-lead, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

67

Copper Cable Solutions


Category 6 Horizontal Cable

Category 6 Bundled Plenum Cable

TrueNet Structured Cabling

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
Impedance
(Ohms)
Freq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
550

Input
Typical
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 8

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
25 nS/100 meters @100MHz
75% @100MHz
Attenuation
(dB/100m)

Characteristic
Typical
100 5
100 3
100 3
100 3
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2

Return Loss
(dB)

Typical

Spec

Typical

Spec

1.6
3.2
4.6
5.2
6.7
7.5
8.4
9.5
13.9
18.3
23.5
27.3
31.3
34.9
38.4
41.8
50.6

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

20.3
35.2
41.1
40.2
41.0
41.1
42.2
39.5
40.6
36.9
38.9
35.5
36.0
35.4
32.5
33.0
28.9

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

102094AE

NEXT

11/11

Copper Cable Solutions

Specifications

Freq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
550

Pair-To-Pair
(dB/100m)
Typical
Spec
96.4
74.3
89.9
65.3
84.6
60.8
85.3
59.3
80.5
56.2
77.5
54.8
78.8
53.3
74.3
51.9
70.4
47.4
68.5
44.3
65.9
41.4
64.1
39.8
61.4
38.3
61.1
60.7
59.1
56.1

PowerSum
(dB/100m)
Typical
Spec
89.6
72.3
83.1
63.3
78.1
58.8
77.2
57.3
72.6
54.2
70.5
52.8
72.0
51.3
67.7
49.9
63.6
45.4
61.5
42.3
58.5
39.4
56.9
37.8
55.1
36.3
53.7
53.5
51.8
47.9

Attenuation-To-NEXT Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical Spec
Typical
Spec
94.8
86.7
80.0
80.1
73.8
70.0
70.4
64.8
56.5
50.2
42.4
36.8
30.1
26.2
22.3
17.3
5.5

72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

88.0
79.9
73.5
72.0
65.9
63.0
63.6
58.2
49.7
43.2
35.0
29.6
23.8
18.8
15.1
10.0
-2.7

70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

ELFEXT
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
92.2
67.8
84.8
64.8
83.3
55.8
74.2
52.8
77.9
49.7
69.4
46.7
74.8
47.8
66.9
44.8
70.2
43.7
62.6
40.7
67.9
41.8
60.2
38.8
66.1
39.8
58.3
36.8
63.7
37.9
55.9
34.9
58.4
31.9
50.5
28.9
54.9
27.8
46.6
24.8
49.2
24.0
41.8
21.0
45.5
21.8
38.1
18.8
43.6
19.8
35.0
16.8
38.9
30.4
34.2
26.3
3.0
22.5
19.2
10.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

68

Copper Cable Solutions


Category 6 Horizontal Cable

Category 6 Bundled Plenum Cable


Ordering Information
Bundled Diameter
(Inches)
0.39"
0.48"
0.58"

3
4
6

Weight
(lbs/kft)
84
112
168

Packaging
1000' Reel
1000' Reel
1000' Reel

Catalog Number*
TNSP-36XX02
TNSP-46XX02
TNSP-66XX02

*To order cable sheath color, replace XX with:

Copper Cable Solutions

BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
ST = Standard bundled colorswhite, blue, gray, orange, yellow, green
*Other reel sizes available, please contact TE Customer Services.

11/11

102094AE

TrueNet Structured Cabling

Number of Cables

www.te.com/adc

+1-952-938-8080

1-800-366-3891

69

Copper Cable Solutions


Category 6 Horizontal Cable

Category 6 Bundled Riser Cable

TrueNet Structured Cabling

Individual 4-pair horizontal cables twisted and


bound together with Kevlar cord
Patented impedance matching for zero-bit
errors
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661

102094AE

NEC 800 Type CMR

11/11

Copper Cable Solutions

Features

ISO/IEC 11801 Class D


TIA/EIA-568-B.2-1 Category 6 horizontal,
individual cables

Specifications
CONSTRUCTION
Conductors:
Insulation:
Individual cable diameter:
Jacket:

24 AWG solid bare copper


Polyolefin
0.21" (5.33mm)
Non-lead, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

70

Copper Cable Solutions


Category 6 Horizontal Cable

Category 6 Bundled Riser Cable

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
550

Impedance
(Ohms)
Input
Typical
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 8

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
45 nS/100 meters @100MHz
75% @100MHz
Attenuation
(dB/100m)

Characteristic
Typical
100 5
100 3
100 3
100 3
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2

Return Loss
(dB)

Typical

Spec

Typical

Spec

1.7
3.5
5.0
5.6
7.1
8.0
9.0
10.1
14.5
18.4
23.2
26.6
29.8
32.8
35.6
38.2
45.3

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

22.4
32.9
39.8
44.1
44.9
43.3
44.6
43.8
40.8
41.1
37.6
36.7
34.3
32.9
30.2
29.8
28.2

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

11/11

102094AE

NEXT
Freq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
550

Pair-To-Pair
(dB/100m)
Typical
Spec
94.4
74.3
86.4
65.3
87.6
60.8
80.6
59.3
79.4
56.2
76.8
54.8
76.3
53.3
73.9
51.9
67.5
47.4
63.8
44.3
63.3
41.4
62.8
39.8
63.3
38.3
60.3
58.7
55.9
53.0

PowerSum
(dB/100m)
Typical
Spec
87.5
72.3
78.9
63.3
77.7
58.8
72.2
57.3
68.2
54.2
69.1
52.8
66.0
51.3
65.3
49.9
58.7
45.4
56.4
42.3
55.0
39.4
52.9
37.8
54.7
36.3
54.0
51.0
50.1
46.4

Attenuation-To-NEXT Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical Spec
Typical
Spec
92.7
82.9
82.7
75.0
72.3
68.8
67.3
63.8
53.0
45.4
40.0
36.2
33.5
27.5
23.1
17.7
7.8

72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

85.8
75.4
72.7
66.5
61.1
61.1
57.0
55.2
44.2
38.0
31.8
26.4
24.9
21.2
15.4
11.9
1.1

70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

ELFEXT
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
93.1
67.8
87.4
64.8
83.6
55.8
76.2
52.8
77.9
49.7
70.8
46.7
74.0
47.8
67.1
44.8
72.8
43.7
65.6
40.7
69.8
41.8
61.9
38.8
66.8
39.8
59.3
36.8
66.3
37.9
58.6
34.9
58.9
31.9
51.5
28.9
52.7
27.8
45.4
24.8
48.8
24.0
40.6
21.0
46.5
21.8
38.2
18.8
44.2
19.8
35.4
16.8
43.3
34.9
41.1
32.6
40.3
32.7
35.5
29.2

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

71

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions


Category 6 Horizontal Cable

Category 6 Bundled Riser Cable


Ordering Information

3
4
6

Weight
(lbs/kft)
84
93
140

Packaging
1000' Reel
1000' Reel
1000' Reel

Catalog Number*
TNSR-36XX02
TNSR-46XX02
TNSR-66XX02

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
ST = Standard bundled colorswhite, blue, gray, orange, yellow, green
*Other reel sizes available, please contact TE Customer Services.

102094AE

TrueNet Structured Cabling

Bundled Diameter
(Inches)
0.49"
0.49"
0.62"

11/11

Copper Cable Solutions

Number of Cables

www.te.com/adc

+1-952-938-8080

1-800-366-3891

72

Copper Cable Solutions


Category 6 Limited Combustible Cable

4/16Mbps Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)

Copper Cable Solutions

TrueNet Structured Cabling

Common Applications

622Mbps ATM (ATM Forum)


1000Base-T (Gigabit Ethernet)
1Gigabit Networking System (WGNA)
1.2Gbps ATM (ATM Forum)
77 Channel broadband video

Compliances
UL Subject 444
UL 2424
(UL)-C(UL) Type CMP
UL Type CMP Limited Combustible
ICEA S-90-661
NEC 800 Type CMP
ETL Verified TIA/EIA 568-B.21-1 Category 6
horizontal cable requirements

11/11

102094AE

ISO/IEC 11801 Class E

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Separator:
Jacket:

24 AWG solid bare copper


All 4 pairs 100% FEP
Fluoropolymer
100% FEP

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

73

Copper Cable Solutions


Category 6 Limited Combustible Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400

Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400

Impedance
(Ohms)
Input
Typical
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
30 nS/100 meters @100MHz
77% @100MHz
Attenuation
(dB/100m)

Characteristic
Typical
100 5
100 3
100 3
100 3
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2

Max
2.0
3.7
5.2
5.8
7.3
8.1
9.1
10.2
14.5
18.5
23.2
26.5
29.8
32.8
35.6
38.2

EIA/TIA568 Cat 6
2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

NEXT
Pair-To-Pair
Power Sum
(dB/100m)
(db/100m)
Min
EIA/TIA-568
Min
EIA/TIA-568
Cat 6
Cat 6
81.0
74.3
76.3
72.3
72.0
65.3
67.3
63.3
67.5
60.8
62.8
58.8
66.0
59.3
61.3
57.3
62.9
56.2
58.3
54.2
61.5
54.8
56.8
52.8
60.0
53.3
55.3
51.3
58.6
51.9
53.9
49.9
54.1
47.4
49.4
45.4
51.0
44.3
46.3
42.3
48.1
41.4
43.5
39.4
46.5
39.8
41.8
37.8
45.0
38.3
40.3
36.3
43.8
39.2
42.8
38.2
42.0
37.3

Return Loss
(dB)
Min
20.0
23.6
25.4
26.0
26.0
26.0
25.5
25.0
23.5
22.5
21.6
21.0
20.5
20.1
19.8
19.5

Attenuation-To-NEXT Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
EIA/TIA- Min
EIA/TIA- Min
EIA/TIA568 Cat 6
568 Cat 6
568 Cat 6
20.0
79.0
72.3
74.3
70.3
23.0
68.3
61.5
63.6
59.5
24.5
62.3
55.4
57.6
53.4
25.0
60.2
53.3
55.6
51.3
25.0
55.7
48.7
51.0
46.7
25.0
53.4
46.3
48.7
44.3
24.3
50.9
43.8
46.2
41.8
23.6
48.4
41.2
43.7
39.2
21.5
39.6
32.0
34.9
30.0
20.1
18.8
24.5
16.3
22.5
18.8
25.0
16.3
20.3
14.3
18.0
20.0
10.8
15.3
8.8
17.3
15.3
5.5
10.6
3.5
11.1
6.4
7.3
2.6
3.8
-0.9
ELFEXT

Pair-To-Pair
(dB/100m)
Min
EIA/TIA-568
Cat 6
68.8
67.8
56.7
55.8
50.7
49.7
48.8
47.8
44.7
43.7
42.7
41.8
40.8
39.8
38.9
37.9
32.8
31.9
28.8
27.8
24.9
24.0
22.7
21.8
20.8
19.8
19.2
17.9
16.7

Min
65.8
53.7
47.7
45.8
41.7
39.7
37.8
35.9
29.8
25.8
21.9
19.7
17.8
16.2
14.9
13.7

PowerSum
(dB/100m)
EIA/TIA-568
Cat 6
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
21.0
18.8
16.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

74

Copper Cable Solutions


Category 6 Limited Combustible Cable
Ordering Information
Description

Weight (Lbs/kft)

Catalog Number

Reel packaging1000'

31

TN6ESD-CL02

Reel in a box1000'

33

TN6ESD-CLRB

Reel packaging1000'

31

TN6ESD-BL02

Reel in a box1000'

33

TN6ESD-BLRB

Copper Cable Solutions

4-pair cable, blue jacket


Nominal OD: 0.205" (5.2mm)
Maximum Average OD: 0.205" (5.2mm)

11/11

102094AE

TrueNet Structured Cabling

4-pair cable, clear jacket


Nominal OD: 0.205" (5.2mm)
Maximum Average OD: 0.205" (5.2mm)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

75

Copper Cable Solutions


Category 6 Outdoor Cable

Features
Patented AirES conductor insulation technology enables improved signal strength
and speed with superior electrical performance
Manufactured with lead free materials
Moisture barrier core wrap protects pairs

102094AE

TrueNet Structured Cabling

The Outback cable is a 4-pair, 23 gauge Category


6 data cable designed for outdoor use. The cable
combines excellent transmission performance and
weather resistant properties. It is intended for
outdoor installation, in buried conduit or as aerial
cable. The core contains a water blocking tape
which isolates the core from moisture.

11/11

Copper Cable Solutions

C6T 4 Pair Outdoor Cable

www.te.com/adc

+1-952-938-8080

1-800-366-3891

76

Copper Cable Solutions

Category 6 Outdoor Cable

C6T 4 Pair Outdoor Cable

11/11

102094AE

CONSTRUCTION
Conductor:
Insulation:
Filler:
Core Tape:
Jacket:

23 AWG solid bare copper


Polyolefin
Polyolefin Star
Moisture barrier core wrap
Linear Low Density Polyethylene, Black 0.260" (6.6mm) nominal O.D.

Compliances:

ETL Verified TIA/EIA-568-B.2-1 Category 6 Horizontal


ISO/IEC 11801 Category 6 Horizontal Cable Requirements

Common Applications:
4/16 Mb/s Token Ring (IEEE 802.5)
10BASE-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video
100BASE-T (Fast Ethernet)
100BASE-T4 (Fast Ethernet)
100BASE-TX (Fast Ethernet)
THERMAL CHARACTERISTICS
Transport and Storage:
Installation:
Operation:

100VG-Any LAN (IEEE 802.12)


52/155 Mb/s ATM (ATM Forum)
622 Mb/s ATM (ATM Forum)
1000BASE-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
1.2 Gb/s ATM (ATM Forum)
77 Channel Broadband Video

-20 C to 75 C
4 C to 50 C
-20 C to 75 C

MECHANICAL CHARACTERISTICS
Bend Radius
During Installation:
8 X O.D.
Installed:
4 X O.D.
Pull Tension:
25# (11ON)
ELECTRICAL CHARACTERISTICS
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


2%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
66%

Ordering Information
Description

Weight
LBS/KFT

Reel 1000'

www.te.com/adc

29

Catalog Number

KG/KM
TN6TOSP-BK02

42.5

+1-952-938-8080

1-800-366-3891

77

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions

Category 6 Outdoor Cable

C6T 4 Pair Outdoor Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

FREQ
MHZ

FITTED
IMPEDANCE
Ohms

INSERTION
LOSS
dB/100m

RETURN
LOSS
dB/100m

PAIR-PAIR
NEXT
dB/100m

PSNEXT
dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

Min

Spec

100 +/-3

1.7

2.0

26.2

20.0

83.9

74.3

80.8

72.3

100 +/-3

3.4

3.8

33.8

22.9

80.0

65.3

76.4

63.3

100 +/-3

4.8

5.3

34.5

24.5

74.0

60.8

72.3

58.8

10

100 +/-3

5.4

6.0

37.2

25.0

68.6

59.3

67.5

57.3

16

100 +/-3

6.8

7.6

33.5

25.0

71.0

56.2

68.8

54.2

20

100 +/-3

7.6

8.5

34.8

25.0

62.7

54.8

62.2

52.8

25

100 +/-3

8.6

9.5

36.1

24.3

59.1

53.3

58.6

51.3

31.25

100 +/-3

9.6

10.7

38.8

23.6

67.2

51.9

64.7

49.9

62.5

100 +/-3

13.6

15.4

35.2

21.5

56.8

47.4

54.1

45.4

100

100 +/-3

17.3

19.8

35.0

20.1

53.7

44.3

52.1

42.3

155

100 +/-3

21.7

25.2

32.8

18.8

53.6

41.4

51.9

39.4

200

100 +/-3

24.8

29.0

32.9

18.0

47.3

39.8

45.7

37.8

250

100 +/-3

27.8

32.8

31.3

17.3

49.1

38.3

47.2

36.3

300

100 +/-3

30.6

31.3

49.4

46.5

350

100 +/-3

33.1

30.0

49.1

46.7

400

100 +/-3

35.5

26.6

41.3

40.6

550

100 +/-3

42.1

22.3

42.1

40.4

FREQ
MHZ

PAIR-PAIR
ACR
dB/100m

PSACR
dB/100m

PAIR-PAIR
ELFEXT
dB/100m

PSELFEXT
dB/100m

LCL
dB/100m

Min

Spec

Min

Spec

Min

Spec

Min

Spec

Min

82.3

72.3

79.2

70.3

79.4

67.8

75.1

64.8

40.0

76.6

61.5

73.1

59.5

67.7

55.8

63.3

52.8

40.0

69.4

55.4

67.5

53.4

61.6

49.7

57.3

46.7

40.0

10

63.4

53.3

62.2

51.3

59.4

47.8

55.2

44.8

40.0

16

64.2

48.7

62.0

46.7

54.8

43.7

51.3

40.7

38.0

20

55.3

46.3

54.7

44.3

52.5

41.8

49.6

38.8

37.0

25

50.8

43.8

50.1

41.8

49.6

39.8

47.4

36.8

36.0

31.25

57.8

41.2

55.4

39.2

47.6

37.9

45.6

34.9

35.1

62.5

43.4

32.0

40.8

30.0

42.4

31.9

39.7

28.9

32.0

100

36.9

24.5

35.3

22.5

38.3

27.8

35.5

24.8

30.0

155

32.1

16.3

30.4

14.3

37.6

24.0

34.7

21.0

28.1

200

23.0

10.8

21.0

8.8

35.1

21.8

33.3

18.8

27.0

250

21.9

5.5

20.0

3.5

27.5

19.8

26.8

16.8

26.0

300

19.8

16.8

25.3

23.9

350

16.3

14.0

27.3

25.0

400

6.2

5.5

29.4

27.6

550

1.0

23.9

23.7

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual
compliance testing is based on swept frequency measurements. The spec values are based on TIA/EIA-568-B.2-1 specification.
www.te.com/adc

+1-952-938-8080

1-800-366-3891

78

Copper Cable Solutions


Category 5e Horizontal Cable
Category 5e Plenum Cable

TrueNet Category 5e Plenum cable


is protected by US Patents 6153826

TrueNet Category 5e Plenum cable


is also available in a side-by-side configuration

Common Applications

Compliances

4/16Mbps Token Ring (IEEE 802.5)

UL Subject 444

10Base-T (IEEE 802.3)

(UL)-C(UL) Type MPP/CMP

100Mbps TP-PMD

ICEA S-90-661

Broadband and baseband video

NEC 800 Type CMP

100Base-T (Fast Ethernet)

ISO/IEC 11801 Class D

100Base-T4 (Fast Ethernet)

ETL verified TIA/EIA-568-B.2-1 Category 5e


horizontal cable requirements

100Base-TX (Fast Ethernet)


100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)

11/11

102094AE

1Gbps Networking System (WGNA)

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Pairing:
Color-coding:
Jacket:

24 AWG solid bare copper


100% FEP
Short, staggered pair lays
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

79

Copper Cable Solutions

TrueNet Structured Cabling

Copper Cable Solutions


Category 5e Horizontal Cable
Category 5e Plenum Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
FITTED
FREQ IMPEDANCE
(MHz)
(Ohms)
SPEC
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
FREQ
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

5
3
3
3
3
3
3
3
3
3
3
3
3
3
3

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
22 nS/100 meters @100MHz
76%

INSERTION LOSS
(dB/100m)

RETURN LOSS
(dB/100m)

Max

TIA Spec

Min

1.9
3.7
5.3
6.0
7.6
8.6
9.6
10.8
15.5
19.8
25.1
28.9
32.5
35.9
39.3

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

Pair-Pair ACR
(dB/100m)

33.1
30.1
32.7
31.4
37.0
37.5
35.1
34.4
33.2
29.8
29.3
22.9
25.0
22.5
22.4

PSACR
(dB/100m)

Min

TIA Spec

Min

TIA Spec

78.0
68.6
59.1
57.8
53.8
51.2
49.0
47.9
36.9
29.4
26.2
18.7
10.1
7.7
1.8

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

76.3
64.2
58.1
56.4
52.0
49.4
47.3
44.1
34.8
27.4
22.8
16.6
8.6
5.2
0.3

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

Pair-Pair NEXT
(dB/100m)

TIA Spec

Min

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

79.8
72.4
64.4
63.7
61.4
59.7
58.7
58.7
52.4
49.3
51.3
47.5
42.6
43.6
41.1

Pair-Pair ELFEXT
(dB/100m)
Min

TIA Spec

70.2
58.9
52.8
51.1
47.4
45.0
43.0
41.4
35.2
32.0
28.7
27.4
25.8
24.4
22.8

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

PSNEXT
(dB/100m)

TIA Spec
65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

Min
78.1
67.9
63.5
62.4
59.7
58.0
56.9
54.9
50.3
47.2
47.9
45.5
41.1
41.1
39.6

TIA Spec
62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

PSELFEXT
(dB/100m)
Min
70.0
58.7
52.5
50.8
47.1
44.9
42.6
41.1
35.2
31.7
28.6
27.3
25.4
23.8
22.1

TIA Spec
60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only.
Actual compliance testing is based on swept frequency measurements. The spec values are also based on the
TIA/EIA-568-B.2 specification.

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

80

Copper Cable Solutions


Category 5e Horizontal Cable
Category 5e Plenum Cable
Ordering Information
Weight (Lbs/kft)

Catalog Number*

4-pair cable
Nominal OD: 0.180" (4.57mm)
Maximum Average OD: 0.185" (4.7mm)
Reel packaging

21

TN5ESP-XXYY

Reel in a box1000'

23

TN5ESP-XXRB

Reelex1000'

21

TN5ESP-XXII

4-pair, side-by-side cable


Nominal OD: 0.19" x 0.40" (4.83mm x 10.16mm)

50

TN5ESPX2-XXYY

Copper Cable Solutions

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
*To designate reel length, replace YY with:
02 = 1000'
04 = 2000'

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

81

Copper Cable Solutions


Category 5e Horizontal Cable
Category 5e Riser Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

TrueNet Category 5e riser cable


is protected by US Patent 6153826

TrueNet Category 5e riser cable is also


available in a side-by-side configuration

Common Applications

Compliances

4/16Mbps Token Ring (IEEE 802.5)

UL Subject 444

10Base-T (IEEE 802.3)

(UL)-C(UL) Type CMR/CMG

100Mbps TP-PMD

ICEA S-90-661

Broadband and baseband video

NEC 800 Type CMR

100Base-T (Fast Ethernet)

ISO/IEC 11801 Category 5e

100Base-T4 (Fast Ethernet)

ETL verified TIA/EIA-568-B.2-1 Category 5e


horizontal cable requirements

100Base-TX (Fast Ethernet)


100VG-AnyLAN ( IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Jacket:

24 AWG solid bare copper


Polyolefin
Short, staggered pair lays
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

82

Copper Cable Solutions


Category 5e Horizontal Cable
Category 5e Riser Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

FREQ
(MHz)

FITTED
IMPEDANCE
(Ohms)
SPEC

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

FREQ
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

5
3
3
3
3
3
3
3
3
3
3
3
3
3
3

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
22 nS/100 meters @100MHz
70%

INSERTION LOSS
(dB/100m)

RETURN LOSS
(dB/100m)

Max

Min

TIA Spec

Min

TIA Spec

Min

33.7
38.9
35.6
36.4
36.9
35.1
36.4
33.3
31.6
32.8
23.7
24.8
23.3
21.9
21.7

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

80.2
68.7
63.0
61.8
59.0
60.0
55.7
53.7
51.6
46.4
44.6
46.6
42.1
42.0
34.5

65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

78.0
66.6
61.7
59.2
55.8
58.3
54.2
52.3
50.4
44.1
43.1
43.3
40.8
39.1
32.9

TIA Spec

1.9
3.8
5.4
6.1
7.7
8.7
9.8
10.9
15.6
20.0
25.1
28.8
32.2
35.5
38.6

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

Pair-Pair ACR
(dB/100m)

PSACR
(dB/100m)

Min

TIA Spec

Min

TIA Spec

78.3
64.9
57.5
55.7
51.3
51.3
46.0
42.7
36.0
26.4
19.4
17.8
9.8
6.6

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

76.1
62.8
56.3
53.1
48.1
49.6
44.4
41.4
34.8
24.1
18.0
14.5
8.6
3.7

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

Pair-Pair NEXT
(dB/100m)

Pair-Pair ELFEXT
(dB/100m)
Min

74.6
63.5
56.0
54.1
51.2
49.3
47.9
45.2
39.4
36.6
30.4
28.0
24.9
24.7
22.8

PSNEXT
(dB/100m)
TIA Spec

62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

PSELFEXT
(dB/100m)

TIA Spec

Min

TIA Spec

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

73.8
62.5
55.4
53.8
50.7
48.7
47.2
44.8
38.8
35.7
29.5
28.0
23.7
24.8
21.6

60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2 specifications.

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

83

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions


Category 5e Horizontal Cable
Category 5e Riser Cable
Ordering Information
Catalog Number*

Reel packaging

20

TN5ESR-XXYY

Reelex1000'

20

TN5ESR-XXII

Reel in a box1000'

22

TN5ESR-XXRB

4-pair, side-by-side cable


Nominal OD: 0.19" x 0.40" (4.83mm x 10.16mm)

52

TN5ESRX2-XXYY

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
*To designate reel length, replace YY with:
02 = 1000'
04 = 2000'

102094AE

TrueNet Structured Cabling

Weight (Lbs/kft)

4-pair cable
Nominal OD: 0.185" (4.7mm)

11/11

Copper Cable Solutions

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

84

Copper Cable Solutions


Category 5e Horizontal Cable

Category 5e Bundled Riser Cable

4/16Mbps Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN ( IEEE 802.12)
622Mbps ATM (ATM Forum)

Copper Cable Solutions

TrueNet Category 5e bundled cable


is protected by US Patent 6153826

52/155Mbps ATM (ATM Forum)


1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR
TIA/EIA-568-B.2 Category 5e horizontal,
individual cables

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Jacket:

24 AWG solid bare copper


100% Polyolefin
Lead-free, flame retardant PVC

11/11

102094AE

TrueNet Structured Cabling

Common Applications

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

85

Copper Cable Solutions


Category 5e Horizontal Cable

Category 5e Bundled Riser Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

Impedance
(Ohms)

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
45 nS/100 meters @100MHz
70% @100MHz

Attenuation
(dB)

Return Loss
(dB)

Characteristic
Typical

Input
Typical

Typical

Spec

Typical

Spec

100 10
100 8
100 6
100 6
100 5
100 5
100 4
100 4
100 3
100 3
100 3
100 3

100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10

1.8
3.7
5.2
5.8
7.5
8.4
9.4
10.5
15.1
19.5
24.4
27.8
31.5
34.8
37.6

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

44.5
46.2
45.1
41.6
44.5
44.3
43.4
43.5
41.4
42.1
43.7
39.6
38.6
40.0
37.5

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

NEXT
Pair-To-Pair
(dB/100m)
Typical
Spec
87.1
77.1
70.6
70.8
67.8
66.9
64.0
63.6
58.6
55.5
52.1
49.9
48.5
48.2
46.4

65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

PowerSum
(dB/100m)
Typical
Spec
80.6
70.1
63.9
63.9
60.6
59.9
57.5
56.1
51.9
49.5
45.4
43.6
42.1
41.4
39.9

Bundled
PowerSum
Spec

62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

65.0
59.3
54.8
53.3
50.2
48.8
47.3
45.9
41.4
38.3

Attenuation-To-NEXT-Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
85.3
73.4
65.4
64.7
60.4
58.5
54.6
53.1
43.6
36.0
27.7
22.2
17.1
13.4
8.8

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

78.8
66.3
58.6
58.1
53.1
51.5
48.1
45.5
36.8
29.9
21.0
15.8
10.5
6.5
2.3

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

ELFEXT
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
85.0
75.2
67.4
65.4
60.8
58.6
56.3
55.0
48.9
45.2
41.2
38.2
35.0
32.4
29.6

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

77.5
66.5
59.1
57.9
53.5
51.4
49.5
48.2
42.0
38.7
34.8
31.5
28.6
26.2
22.6

60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

86

Copper Cable Solutions


Category 5e Horizontal Cable

Category 5e Bundled Riser Cable


Ordering Information
Bundled Diameter
(Inches)
0.37"
0.40"
0.54"

3
4
6

Weight
(lbs/kft)
71
95
143

Packaging
Reel
Reel
Reel

Catalog Number*
TNSR-3EXX02
TNSR-4EXX02
TNSR-6EXX02

*To order cable sheath color, replace XX with:

Copper Cable Solutions

BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
ST = Standard bundled colors

11/11

102094AE

TrueNet Structured Cabling

Number of Cables

www.te.com/adc

+1-952-938-8080

1-800-366-3891

87

Copper Cable Solutions


Category 5e Outdoor Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Category 5e The Outback Outdoor Cable


The Outback cable is a 4-pair, 24 gauge, Category
5e data cable designed for outdoor use. The
cable combines excellent transmission and weather
resistant properties. It is intended for outdoor
installation, in buried conduit, or as aerial cable.
The core contains a heat and water-blocking tape,
which isolates the core from extreme temperature
and moisture.
Common Applications

Category 5e The Outback Cable is protected


by US Patent 6153826

4/16Mbps Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN ( IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)

Compliances

1000Base-T (Gigabit Ethernet)

TIA/EIA-568-B.2 Category 5e horizontal


cable requirements

1Gbps Networking System (WGNA)

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Core tape:
Jacket:

24 AWG solid bare copper


100% Polyolefin
Short, staggered pair lays
See Technical Reference Section, UTP color-code table
Heat and moisture barrier core wrap
Linear low-density Polyethelyene, black

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
45 nS/100 meters @100MHz
69% @100MHz

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

88

Copper Cable Solutions


Category 5e Outdoor Cable

Category 5e The Outback Outdoor Cable

Freq
(MHz)

Attenuation
(dB)

Return Loss
(dB)

Characteristic
Typical

Input
Typical

Typical

Spec

Typical

Spec

100 10
100 8
100 6
100 6
100 5
100 5
100 4
100 4
100 3
100 3
100 3
100 3

100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10

1.8
3.7
5.2
5.8
7.5
8.4
9.4
10.5
15.1
19.5
24.4
27.8
31.5
34.8
37.6

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

44.5
46.2
45.1
41.6
44.5
44.3
43.4
43.5
41.4
42.1
43.7
39.6
38.6
40.0
37.5

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

Attenuation-To-NEXT-Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
85.3
73.4
65.4
64.7
60.4
58.5
54.6
53.1
43.6
36.0
27.7
22.2
17.1
13.4
8.8

NEXT
Pair-To-Pair
(dB/100m)
Typical
Spec

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

87.1
77.1
70.6
70.8
67.8
66.9
64.0
63.6
58.6
55.5
52.1
49.9
48.5
48.2
46.4

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

78.8
66.3
58.6
58.1
53.1
51.5
48.1
45.5
36.8
29.9
21.0
15.8
10.5
6.5
2.3

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

ELFEXT
PowerSum
(dB/100m)
Typical
Spec

65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

80.6
70.1
63.9
63.9
60.6
59.9
57.5
56.1
51.9
49.5
45.4
43.6
42.1
41.4
39.9

Pair-To-Pair
(dB/100m)
Typical
Spec

62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

85.0
75.2
67.4
65.4
60.8
58.6
56.3
55.0
48.9
45.2
41.2
38.2
35.0
32.4
29.6

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

PowerSum
(dB/100m)
Typical
Spec
77.5
66.5
59.1
57.9
53.5
51.4
49.5
48.2
42.0
38.7
34.8
31.5
28.6
26.2
22.6

60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are also based on the TIA/EIA-568-B.2 specification.

11/11

Ordering Information
Description

Weight (Lbs/kft)

Catalog Number

4-pair cable
Nominal OD: 0.22" (5.59mm), black jacket
Reel packaging1000'

www.te.com/adc

21

+1-952-938-8080

TN5ETOSP-BK02

1-800-366-3891

89

Copper Cable Solutions

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

Impedance
(Ohms)

102094AE

TrueNet Structured Cabling

Freq
(MHz)

Copper Cable Solutions


Category 5e Backbone Cable

25-Pair Category 5e Plenum Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Features
Verified to Category 5e standard
24 AWG solid copper conductors
Lead-free, flame retardant PVC
100 Ohm nominal impedance

Compliances
UL subject 444
(UL)-C(UL) type CMP
ICEA S-90-661
NEC 800 type CMP
ETL verified TIA/EIA-568-B.2 Category 5e
horizontal cable requirements

Specifications
CHARACTERISTICS:
Conductor:
Insulation:
Jacket:

24 AWG solid bare copper


100% FEP
Fluropolymer, .460" (11.7 mm) nominal O.D.

COMMON APPLICATIONS:
4/16 Mb/s Token Ring (IEEE 802.5)
10BASE-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video
100BASE-T (Fast Ethernet )
100BASE-T4 (Fast Ethernet)
100BASE-TX (Fast Ethernet)
100VG-Any LAN (IEEE 802.12)
52/155 Mb/s ATM (ATM Forum)
622 Mb/s ATM (ATM Forum)
1000BASE-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
THERMAL CHARACTERISTICS:
Transport and Storage:
Installation:
Operation:

-50C to 200C
-50C to 200C
-50C to 200C

MECHANICAL CHARACTERISTICS:
Bend Radius:

6.9" (175 mm)

ELECTRICAL CHARACTERISTICS:
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


5%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
72%

www.te.com/adc

+1-952-938-8080

1-800-366-3891

90

Copper Cable Solutions

Category 5e Backbone Cable

11/11

102094AE

FREQ

Fitted
Impedance

MHZ

Ohms

Insertion Loss

Pair-Pair NEXT

dB/100m

PSNEXT

dB/100m

dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

100 +/- 15

2.0

2.0

71.7

65.3

69.6

62.3

100 +/- 15

4.0

4.1

64.1

56.3

60.8

53.3

100 +/- 15

5.6

5.8

57.9

51.8

56.3

48.8

10

100 +/- 15

6.3

6.5

57.2

50.3

55.2

47.3

16

100 +/- 15

8.1

8.2

54.2

47.2

51.7

44.2

20

100 +/- 15

9.2

9.3

53.1

45.8

50.0

42.8

25

100 +/- 15

10.2

10.4

48.5

44.3

46.8

41.3

31.25

100 +/- 15

11.5

11.7

50.9

42.9

48.0

39.9

62.5

100 +/- 15

16.5

17.0

46.6

38.4

44.0

35.4

100

100 +/- 15

21.3

22.0

42.5

35.3

39.9

32.3

FREQ

Return Loss

Pair-Pair ELFEXT

PSELFEXT

MHZ

dB/100m

dB/100m

dB/100m

Max

Spec

Min

Spec

Min

Spec

26.6

20.0

67.3

63.8

65.8

60.8

27.1

23.0

55.8

51.8

54.2

48.8

28.5

24.5

49.9

45.7

48.3

42.7

10

29.8

25.0

47.8

43.8

46.3

40.8

16

29.5

25.0

43.9

39.7

42.3

36.7

20

30.4

25.0

41.9

37.8

40.3

34.8

25

31.2

24.3

40.1

35.8

38.5

32.8

31.25

30.7

23.6

38.1

33.9

36.5

30.9

62.5

26.7

21.5

32.5

27.9

30.8

24.9

100

24.6

20.1

29.0

23.8

27.3

20.8

Copper Cable Solutions

TrueNet Structured Cabling

25-Pair Category 5e Plenum Cable

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA-568-B.2 specification.

Ordering Information
Description

Catalog Number

1000 foot reel, 142 lbs (210 kg), White

5ETP-2524WT02

www.te.com/adc

+1-952-938-8080

1-800-366-3891

91

Copper Cable Solutions


Category 5e Backbone Cable

25-Pair Category 5e Riser Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Solutions

Features
Verified to Category 5e standard
24 AWG solid copper conductors
Lead-free, flame retardant PVC
100 Ohm nominal impedance

Compliances
UL subject 444
(UL)-C(UL) type CMR/CMG
ICEA S-90-661
NEC 800 type CMR
ETL verified TIA/EIA-568-B.2 Category 5e
horizontal cable requirements

Specifications
CONSTRUCTION:
Conductor:
Insulation:
Jacket:

24 AWG solid bare copper


HDPE
Flame-retardant PVC, .500" (12.7 mm) nominal O.D.

COMMON APPLICATIONS:
4/16 Mb/s Token Ring (IEEE 802.5)
10BASE-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video
100BASE-T (Fast Ethernet)
100BASE-T4 (Fast Ethernet)
100BASE-TX (Fast Ethernet)
100VG-Any LAN (IEEE 802.12)
52/155 Mb/s ATM (ATM Forum)
622 Mb/s ATM (ATM Forum)
1000BASE-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
THERMAL CHARACTERISTICS:
Transport and Storage:
Installation:
Operation:

-10C to 60C
-0C to 50C
-10C to 60C

MECHANICAL CHARACTERISTICS:
Bend Radius:

5.0" (127 mm)

ELECTRICAL CHARACTERISTICS:
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


5%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
70%

www.te.com/adc

+1-952-938-8080

1-800-366-3891

92

Copper Cable Solutions

Category 5e Backbone Cable

11/11

102094AE

FREQ

Fitted
Impedance

MHZ

Ohms

Insertion Loss

Pair-Pair NEXT

dB/100m

PSNEXT

dB/100m

dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

100 +/- 15

2.0

2.0

71.7

65.3

69.6

62.3

100 +/- 15

4.0

4.1

64.1

56.3

60.8

53.3

100 +/- 15

5.6

5.8

57.9

51.8

56.3

48.8

10

100 +/- 15

6.3

6.5

57.2

50.3

55.2

47.3

16

100 +/- 15

8.1

8.2

54.2

47.2

51.7

44.2

20

100 +/- 15

9.2

9.3

53.1

45.8

50.0

42.8

25

100 +/- 15

10.2

10.4

48.5

44.3

46.8

41.3

31.25

100 +/- 15

11.5

11.7

50.9

42.9

48.0

39.9

62.5

100 +/- 15

16.5

17.0

46.6

38.4

44.0

35.4

100

100 +/- 15

21.3

22.0

42.5

35.3

39.9

32.3

FREQ

Return Loss

Pair-Pair ELFEXT

PSELFEXT

MHZ

dB/100m

dB/100m

dB/100m

Max

Spec

Min

Spec

Min

26.6

20.0

67.3

63.8

65.8

60.8

27.1

23.0

55.8

51.8

54.2

48.8

28.5

24.5

49.9

45.7

48.3

42.7

10

29.8

25.0

47.8

43.8

46.3

40.8

16

29.5

25.0

43.9

39.7

42.3

36.7

20

30.4

25.0

41.9

37.8

40.3

34.8

Copper Cable Solutions

TrueNet Structured Cabling

25-Pair Category 5e Riser Cable

Spec

25

31.2

24.3

40.1

35.8

38.5

32.8

31.25

30.7

23.6

38.1

33.9

36.5

30.9

62.5

26.7

21.5

32.5

27.9

30.8

24.9

100

24.6

20.1

29.0

23.8

27.3

20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA-568-B.2 specification.

Ordering Information
Description

Catalog Number

1000 foot reel, 132 lbs (195 kg), Gray

5ETR-2524GY02

www.te.com/adc

+1-952-938-8080

1-800-366-3891

93

Copper Cable Solutions

Category 3 Horizontal and Backbone Cable


Category 3 Plenum Cable

TrueNet Structured Cabling

T1 and T1 Fractional
ISDN Basic and Primary Rate
4/16Mbps Token Ring (IEEE 802.5)
10Base-t (IEEE 802.3)
52Mbps ATM (ATM Forum)
100Base-T4 (Fast Ethernet)
100VG-AnyLAN (IEEE 802.12)

Compliances
UL Subject 444
(UL)-C(UL) Type CMP
ICEA S-90-661
NEC 800 Type CMP
Two- to four-pair: TIA/EIA-568-B.2
Category 3 horizontal cable
Over four-pair: TIA/EIA-568-B.2
Category 3 backbone cable

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Rip cord:
Jacket:

24 AWG solid bare copper


LS-flame retardant PVC
Short, staggered pair lays
See Technical Reference Section, 25-pair color-code table
Applied under jacket
LS-flame retardant PVC (2- to 100-pair)
PVDF Copolymer (Over 100-pair)

102094AE

POTS

11/11

Copper Cable Solutions

Common Applications

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

94

Copper Cable Solutions

Category 3 Horizontal and Backbone Cable


Category 3 Plenum Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Insulation resistance (minimum):
Mutual capacitance (typical):
Operating temperature (maximum):
Operating voltage (maximum):

28.6/1000 feet (9.38/100 meters) @20C


5%
500 Megohms/1000 feet @20C
19 pF/foot (5.6nF/100 meters)
20 pF/foot (5.6nF/100 meters)
60C
300VDC

Frequency
(MHz)

Impedance
(Ohms)

Attenuation
Max
(dB/100m)

1.0
4.0
8.0
10.0
16.0

85115
85115
85115
85115
85115

2.6
5.6
8.5
9.7
13.1

NEXT
Min
(dB)

SRL
Min
(dB)

41
32
27
26
23

12
12
12
12
10

Notes: (1) Compliance testing for the above parameters is based on Swept Frequency Measurements.
(2) NEXT = Near-End Crosstalk. NEXT requirements for cables up to and including 4 pair are for Worst-Case-Pair NEXT. Cables over
4 pair are subject to PowerSum NEXT requirements.

Ordering Information
Description

OD
(Inches)

Weight
(Lbs/kft)

Packaging

Catalog Number*

Reelex1000'
Reelex1000'
Reelex1000'
Reelex1000'
Spool
Spool
Spool
Reel
Reel
Reel
Reel
Reel
Reel
Reel
Reel

VXV0224-19R2
VXV0324-19R2
VXV0424-19R2
VXV0624-19R2
VXV0224-19YY
VXV0324-19YY
VXV0424-19YY
VXV0624-19YY
VXV0824-19YY
VXV1224-19YY
VXV2524-19XX
VXV5024-19YY
VXV7524-19YY
VXV0024-19YY
VXCCC24-19YY

Category 3 Plenum cable


Jacket color: white
2-pair
3-pair
4-pair
6-pair
2-pair
3-pair
4-pair
6-pair
8-pair
12-pair
25-pair
50-pair
75-pair
100-pair
200-pair

0.14
0.15
0.17
0.19
0.14
0.15
0.17
0.19
0.24
0.28
0.38
0.55
0.68
0.76
1.11

12
15
19
27
12
15
19
27
39
54
106
210
310
430
1052

*To designate reel length, replace YY with:


02 = 1000'
10 = 5000'
Dimensions and weights are calculated nominals and do not imply any minimum or maximum tolerance

www.te.com/adc

+1-952-938-8080

1-800-366-3891

95

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions

Category 3 Horizontal and Backbone Cable


Category 3 Riser Cable

TrueNet Structured Cabling

T1 and T1 Fractional
ISDN Basic and Primary Rate
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)
52Mbps ATM (ATM Forum)
100Base-T4 (Fast Ethernet)
100VG-AnyLAN (IEEE 802.12)

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR
Two- to four-pair: TIA/EIA-568-B.2
Category 3 horizontal cable
Over four-pair: TIA/EIA-568-B.2
Category 3 backbone cable

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:

24 AWG solid bare copper


Lead-free, flame retardant PVC
Staggered pair lays
Standard telephony
(See Technical Reference Section, 25-pair color-code table)
Applied under jacket
Lead-free, flame retardant PVC

Rip cord:
Jacket:

102094AE

POTS

11/11

Copper Cable Solutions

Common Applications

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

96

Copper Cable Solutions

Category 3 Horizontal and Backbone Cable


Category 3 Riser Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Insulation resistance (minimum):
Mutual capacitance (typical):
Operating temperature (maximum):
Operating voltage (maximum):
Frequency
(MHz)
1.0
4.0
8.0
10.0
16.0

28.6/1000 feet (9.38/100 meters) @20C


5%
500 Megohms/1000 feet @20C
19 pF/foot (5.6nF/100 meters)
20 pF/foot (5.6nF/100 meters)
60C
300VDC

Impedance
(Ohms)

Attenuation
Max
(dB/100m)

85115
85115
85115
85115
85115

2.6
5.6
8.5
9.7
13.1

NEXT
Min
(dB)

SRL
Min
(dB)

41
32
27
26
23

12
12
12
12
10

Notes: (1) Compliance testing for the above parameters is based on Swept Frequency Measurements.
(2) NEXT = Near-End Crosstalk. NEXT requirements for cables up to and including 4 pair are for Worst-Case-Pair NEXT. Cables over
4 pair are subject to PowerSum NEXT requirements.

Ordering Information
Description

OD
(Inches)

Weight
(Lbs/kft)

Packaging

Catalog Number*

0.15
0.16
0.17
0.20
0.15
0.16
0.17
0.21
0.22
0.27
0.38
0.55
0.74
1.12
1.26
1.62

12
16
20
28
12
16
20
29
37
53
108
207
416
847
1282
1667

Reelex1000'
Reelex1000'
Reelex1000'
Reelex1000'
Spool
Spool
Spool
Reel
Reel
Reel
Reel
Reel
Reel
Reel
Reel
Reel

D0224D0-GYR2
D0324D0-GYR2
D0424D0-GYR2
D0624D0-GYR2
D0224D0-GYYY
D0324D0-GYYY
D0424D0-GYYY
D0624D0-GYYY
D0824D0-GYYY
D1224D0-GYYY
D2524D0-GYYY
D5024D0-GYYY
D0024D0-GYYY
DCC24D0-GYYY
D3X24D0-GYYY
D4X24D0-GYYY

Category 3 riser cable


Jacket color: gray
2-pair
3-pair
4-pair
6-pair
2-pair
3-pair
4-pair
6-pair
8-pair
12-pair
25-pair
50-pair
100-pair
200-pair
300-pair
400-pair

*To designate reel length, replace YY with:


02 = 1000'
10 = 5000'
Dimensions and weights are calculated nominals and do not imply any minimum or maximum tolerance

www.te.com/adc

+1-952-938-8080

1-800-366-3891

97

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions

Category 1 Horizontal and Backbone Cable


UTP Plenum Cable

Fractional T1
Basic Rate ISDN
2-, 3-, 4- and 6-pair cables
- 4Mbps Token Ring
- Primary Rate ISDN
- T1

Compliances
UL Subject 444
(UL)-C(UL) Type CMP
ICEA S-90-661
NEC 800 Type CMP

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Rip cord:
Jacket:

24 AWG solid bare copper


LS-flame retardant PVC
2 twists per foot (minimum)
Standard telephony, bandmarked
Applied under jacket
LS-flame retardant PVC (2- to 100-pair)
PVDF Copolymer (Over 100-pair)

102094AE

TrueNet Structured Cabling

POTS

11/11

Copper Cable Solutions

Common Applications

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

98

Copper Cable Solutions

Category 1 Horizontal and Backbone Cable


UTP Plenum Cable

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Insulation resistance (minimum):
Mutual capacitance (typical):
Temperature rating:
Voltage rating:

28.6/1000 feet (9.38/100 meters) @20C


5%
500 Megohms/1000 feet @20C
19 pF/foot (5.6nF/100 meters)
21 pF/foot (5.6nF/100 meters)
60C
300VDC

Impedance
(Ohms, Typical)
2-to-6-Pair
Over 6-Pair

Frequency
(MHz)
.256
.512
.772
1.0

105
102
100
97

Attenuation
(dB/100m, Typical)
2-to-6-Pair
Over 6-Pair

100
95
92
87

1.3
1.9
2.2
2.6

1.4
2.0
2.3
2.7

Ordering Information
Description

OD
(Inches)

Weight
(Lbs/kft)

Packaging

Catalog Number*

0.14
0.15
0.16
0.19
0.21
0.24
0.33
0.49
0.66
0.95

11
15
18
27
31
45
100
192
380
793

Spool
Spool
Spool
Spool
Reel
Reel
Reel
Reel
Reel
Reel

VXV0224-18YY
VXV0324-18YY
VXV0424-18YY
VXV0624-18YY
VXV0824-18YY
VXV1224-18YY
VXV2524-18YY
VXV5024-18YY
VXV0024-18YY
VXVCC24-18YY

24 AWG UTP Plenum cable


Jacket color: white
2-pair
3-pair
4-pair
6-pair
8-pair
12-pair
25-pair
50-pair
100-pair
200-pair

*To designate reel length, replace YY with:


02 = 1000'
10 = 5000'

11/11

Dimensions and weights are calculated nominals and do not imply any minimum or maximum tolerance

www.te.com/adc

+1-952-938-8080

1-800-366-3891

99

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Copper Cable Solutions

Category 1 Horizontal and Backbone Cable


UTP Riser Cable

Fractional T1
Basic Rate ISDN
2-, 3-, 4- and 6-pair cables
- 4 Mbps Token Ring
- Primary Rate ISDN
- T1

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Rip cord:
Jacket:

24 AWG solid bare copper


Lead-free, semi-rigid PVC
2 twists per foot (minimum)
Standard telephony, bandmarked
Applied under jacket
Lead-free, flame retardant PVC

102094AE

TrueNet Structured Cabling

POTS

11/11

Copper Cable Solutions

Common Applications

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

100

Copper Cable Solutions

Category 1 Horizontal and Backbone Cable


UTP Riser Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Insulation resistance (minimum):
Mutual capacitance (typical):
Temperature rating:
Voltage rating:

28.6 /1000 feet (9.38/100 meters) @20C


5%
500 Megohms/1000 feet @20C
19 pF/foot (5.6nF/100 meters)
21 pF/foot (5.6nF/100 meters)
60C
300VDC

Impedance
(Ohms, Typical)
2-To-6-Pair
Over 6-Pair

Frequency
(MHz)
.256
.512
.772
1.0

105
102
100
97

Attenuation
(dB/100m, Typical)
2-To-6-Pair
Over 6-Pair

100
95
92
87

1.3
1.9
2.2
2.6

1.4
2.0
2.3
2.7

Ordering Information
Description

OD
(Inches)

Weight
(Lbs/kft)

Packaging

Catalog Number*

24 AWG UTP riser cable


Jacket color: white
2-pair
3-pair
4-pair
6-pair
8-pair
12-pair
25-pair
50-pair
100-pair
200-pair
300-pair
400-pair

0.13
0.14
0.16
0.18
0.20
0.23
0.32
0.45
0.62
0.91
1.06
1.28

10
14
17
24
31
47
96
177
352
708
1052
1477

Spool
Spool
Spool
Spool
Reel
Reel
Reel
Reel
Reel
Reel
Reel
Reel

D0224H0-GYYY
D0324H0-GYYY
D0424H0-GYYY
D0624H0-GYYY
D0824H0-GYYY
D1224H0-GYYY
D2524H0-GYYY
D5024H0-GYYY
D0024H0-GYYY
DCC24H0-GYYY
D3X24H0-GYYY
D4X24H0-GYYY

*To designate reel length, replace YY with:


02 = 1000'
10 = 5000'
Dimensions and weights are calculated nominals and do not imply any minimum or maximum tolerance

www.te.com/adc

+1-952-938-8080

1-800-366-3891

101

Copper Cable Solutions

TrueNet Structured Cabling

Specifications

Introduction ................................................................... 104


CopperTen UTP Horizontal Cable.................................. 105
CopperTen UTP Patch Panels ........................................ 107

CopperTen UTP Modular Jack ....................................... 112


CopperTen UTP Patch Cords ......................................... 113
CopperTen UTP Faceplate ............................................. 116
CopperTen UTP Surface Mount Box .............................. 117

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

103

Copper Connectivity Solutions Category 6a UTP

CopperTen UTP Termination Blocks............................... 109

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions


Category 6a UTP

Copper Connectivity Solutions


Category 6a UTP

TrueNet Structured Cabling

102094AE

The CopperTen system is the worlds first UTP


structured cabling system with the necessary
characteristics to enable 10Gbps Ethernet
transmission over a full 100 meters. Typical
Category 6 cabling systems are hindered by
the technical combination of insertion loss
and alien crosstalk (interference from adjacent
cables) at higher frequencies. Alien crosstalk
greatly disrupts transmission and high-speed
data communications. The CopperTen system
incorporates patent-pending design and
manufacturing processes that enable the
products to overcome these challenges.

11/11

Copper Connectivity Solutions Category 6a UTP

Introduction

www.te.com/adc

+1-952-938-8080

1-800-366-3891

104

Copper Connectivity Solutions


Category 6a UTP

CopperTen Augmented Category 6 Horizontal Cable


CopperTen Category 6a Plenum Data Cable

Unique oblique elliptical offset filler


for improved alien crosstalk
Features AirES technology
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)

Ordering Information

100Mbps TP-PMD
Broadband and baseband video

Description

100Base-T (Fast Ethernet)

Catalog Number*

4-pair Plenum data cable


1000' reel

100Base-TX (Fast Ethernet)


100VG-Any LAN (IEEE 802.12)

10G-A6TP-XX02

Additional packaging options are available, please


contact TE Technical Assistance Center.

52/155Mbps ATM (ATM Forum)


622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)

*To order jacket color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red

1.2Gbps ATM (ATM Forum)


77 Channel broadband video
10GBase-T Ethernet (802.3an)

Compliances
UL Subject 444
(UL)-C(UL) Type CMP
ICEA S-90-661
NEC 800 Type CMP
TIA/EIA 568-B.2-10 Standards
ISO/IEC 11801 Class EA Horizontal
Cable Requirements

11/11

Specifications
Conductor:
Insulation:
Separator:
Jacket:
Nominal outer diameter:
Maximum average outer diameter:

www.te.com/adc

23 AWG solid bare copper


All 4 pairs 100% FEP
Fluoropolymer
Non-lead, flame retardant PVC
0.275" (7.0mm)
0.275" (7.0mm)

+1-952-938-8080

1-800-366-3891

105

Copper Connectivity Solutions Category 6a UTP

100Base-T4 (Fast Ethernet)

102094AE

TrueNet Structured Cabling

Features

Copper Connectivity Solutions


Category 6a UTP

CopperTen Augmented Category 6 Horizontal Cable


CopperTen Category 6a Riser Data Cable

TrueNet Structured Cabling


102094AE

Unique oblique elliptical offset filler


for improved alien crosstalk
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)
100Mbps TP-PMD

Ordering Information

Broadband and baseband video


100Base-T (Fast Ethernet)

Description

100Base-T4 (Fast Ethernet)

Catalog Number*

4-pair riser data cable

100Base-TX (Fast Ethernet)

1000' reel

100VG-Any LAN (IEEE 802.12)


52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
1.2Gbps ATM (ATM Forum)

10G-A6TR-XX02

Additional packaging options are available, please


contact TE Technical Assistance Center.
*To order jacket color, replace XX with:
BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red

77 Channel broadband video


10GBase-T Ethernet (IEEE 802.3an)
proposed

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR
TIA/EIA 568-B.2-10 Standards
ISO/IEC 11801 Class EA Horizontal
Cable Requirements
Fire load: 822kJ/m (0.23kWh/m)

11/11

Copper Connectivity Solutions Category 6a UTP

Features

Specifications
Conductor:
Insulation:
Separator:
Jacket:
Nominal outer diameter:
Maximum average outer
diameter:

www.te.com/adc

23 AWG solid bare copper


100% Polyolefin
Flame retardant polyolefin
Non-lead, flame retardant PVC
0.295" (7.5mm)
0.295" (7.5mm)

+1-952-938-8080

1-800-366-3891

106

Copper Connectivity Solutions


Category 6a UTP

The CopperTen Augmented Category 6 Angled


Patch Panel optimizes 10 Gb/s transmission
performance with offset jack positioning to
counter the negative effects of alien crosstalk.
The angled port design improves all aspects in
managing horizontal cable and patch cables
while improving density when used with Glide
Cable Management. It also makes modifications
easy, avoids unintended disconnects and cable
damage, and protects bend radius to avoid
violations that result in signal degradation.
An integral part of TEs TrueNet Structured
Cabling System, CopperTen is the worlds first
UTP structured cabling system to enable 10
Gigabit Ethernet over a full 100 meters. Installed
in high-performance networks worldwide,
the systems patent-pending design minimizes
alien crosstalk and insertion loss and meets the
performance requirements of IEEE 802.3an and
TIA 568-B.2-10 standards.

Features
Angled design eases stress on patch cords
while maximizing 10 Gigabit performance
UL1863 Listed
High-density design with 24 ports in a
single rack unit
Unique polymer design helps eliminate
alien crosstalk
Rear cable manager included

Specifications
Operating Temperature Range:
Material Construction:
Color:
Dimensions:
Safety Rating:
Flammability Rating:

-10 to 70 C (14 to 158 F)


Molded glass filled Polycarbonate and 16 gauge cold rolled steel
Black
44.45 mm x 482.6 mm x 139.7 mm (1.75" x 19.0" x 5.5")
UL 1863
UL94 V-0

Ordering Information
Description

Catalog Number

Patch Panel
24-port angled patch panel 1RU unloaded

TPNP-24APC10-UN

24-port angled patch panel 1RU loaded with black CopperTen Jacks

TPNP-24APC10-BK

11/11

Wire Management Bracket for Cabinets in Data Center Applications


CopperTen Cable Manager Bracket

www.te.com/adc

+1-952-938-8080

TPNP-NNC10-WM-BKT

1-800-366-3891

107

Copper Connectivity Solutions Category 6a UTP

102094AE

TrueNet Structured Cabling

CopperTen Augmented Category 6 Patch Panels

Copper Connectivity Solutions


Category 6a UTP
CopperTen Augmented Category 6 Patch Panels
CopperTen Patch Panels

Staggered port design and isolation bar


provide improved alien crosstalk performance

Loaded

One rack unit, 24-port design provides high


density and flexibility
Rear wire manager included
Write-on label area for quick, precise
port labeling
Accepts a wide range of TE connectors
UL 1863 safety rating
Unique polymer design helps eliminate alien
crosstalk

Unloaded

Ordering Information
Description

Dimensions (HxWxD)

1RU, 24-port patch panel

Catalog Number

1.75" x 19" x 3"


(44.45mm x 182.6mm x 76.2mm)

Unloaded

TPNP-NNC10-NN

Loaded with black CopperTen jacks

TPNP-24NC10-BK

102094AE

TrueNet Structured Cabling

Installed with CopperTen jacks, meets TIA/EIA


568-B.2-10 standards

11/11

Copper Connectivity Solutions Category 6a UTP

Features

www.te.com/adc

+1-952-938-8080

1-800-366-3891

108

Copper Connectivity Solutions


Category 6a UTP
CopperTen Termination Blocks

Meets performance requirements of TIA/EIA


568-B.2-10 standards
45-degree silver-plated IDCs provide secure,
reliable gas-tight connections
Color-coded for ease of termination
Meets PowerSum ANEXT for 10G Base-T
channel performance
Each module accommodates five 4-pair UTP
CopperTen cables
Modules are terminated with the standard
KRONE termination tools, and may also be
terminated with a 110 tool
Four-pair to four-pair patch cords are available for Patch By Exception installations
Four-pair to RJ45 cords are available to interface with network and other equipment

Ordering Information
Description

Catalog Number

CopperTen 12-position termination block and mounting kit


Includes: stainless steel 12-position mounting frame; 12 CopperTen
modules with rear cable management, each module accommodating (5)
4-pair CopperTen cables; 12 label holders

6450 1 107-00

CopperTen management kit


Includes: dual cable management rings and cord cover

6450 1 103-00

11/11

102094AE

Description

Dimensions (HxWxD)

Catalog Number

CopperTen 8 pair block


field assembly kit
80-pair (20 port)
Supports field termination of (20)
4 pair cables. Includes (10) 8-pair
CopperTen blocks, (2) horizontal wire
managers, (1) black or gray universal
mounting bracket and (1) type 105
label holder with label and protective
cover

14.75" x 8.25" x 5.25"


(374.7mm x 209.6mm x 33.4mm)

80-pair (20 port) kit;


Including black universal mounting kit

6636 1 598-46

80-pair (20 port) kit;


Including gray universal mounting kit

6636 1 598-06

www.te.com/adc

+1-952-938-8080

1-800-366-3891

109

Copper Connectivity Solutions Category 6a UTP

TrueNet Structured Cabling

Features

Copper Connectivity Solutions


Category 6a UTP
CopperTen Termination Blocks

Features
Supports 10 Gigabit Ethernet over UTP copper to a full 100 meters
Center test port allows for circuit monitoring without service disruption
Unique Patch-by-Exception functionality saves time and money while improving
performance and aesthetics
Design for use with TE TrueNet Universal Mounting System (UMS) and Type 105 Rod-Mount Bracket
20 year TrueNet CopperTen warranty

102094AE

TrueNet Structured Cabling

A key component of the TrueNet channel


solution, TEs highest performing termination
block, offers versatility not possible with patch
panels. The CopperTen 8-pair blocks unique
center port eliminates the need to remove
cables for testing and because patch cords are
temporary, the system saves thousands over
traditional patched solutions. Installations are
hardwired providing the cleanest, most secure,
reliable and high performing Category 6a system
available.

11/11

Copper Connectivity Solutions Category 6a UTP

CopperTen Augmented Category 6 8-Pair Block

www.te.com/adc

+1-952-938-8080

1-800-366-3891

110

Copper Connectivity Solutions


Category 6a UTP
CopperTen Termination Blocks

CopperTen Augmented Category 6 8-Pair Block

Environment for use:

Indoors or in dry enclosure rated IP54 or


greater
-20C to +80C
93% non-condensing
0.4-0.65 (26-22 AWG)*
Typically 0.7-1.4
Up to 200
6N
5N
35N

Operating temperature range:


Maximum relative humidity:
Wire range for solid & stranded copper conductors:
Wire insulation diameter range (PE, PVC):
Number of wire re-terminations:
Wire insertion force (0.5 conductor diameter):
Wire pull out force, radial (0.5 conductor diameter):
Wire pull out force, axial (0.5 conductor diameter):
Number of patching cycles
Modules:
Patch plugs:
Transmission & reliability:

Change of contact interface resistance after reliability testing


to ISO/IEC 11801 and TIA/EIA 568B per through connection.
ie. 2 insulation displacement and 1 disconnection contact joint:
Voltage/current rating at 25C ambient:
Dielectric strength:
Surge voltage strength (1.2/50 sec wave shape):
Surge current strength (8/20 sec wave shape)
Modules:
Patch plugs:
Insulation resistance:
Safety:
Flammability rating of plastic housing:

< 5m Typical
150V AC at 2.5A max.
1.5kV AC
2.5kV
3kA
0.5kA
50,000 M at 500 VDC
UL 1863
UL 94 V0

RoHS compliant to the European Union Directive 2002/95/EC


* Should there be a requirement to terminate cables other than 10 Gigabit cable, a maximum of 2 equal, solid
conductors only, of up to 0.5 conductor diameter can be terminated per slot. Only 1 conductor of stranded
wires per slot can be terminated. If any conductors >0.5 have been terminated, reversal to smaller conductors is
no longer possible.

Ordering Information
Description

Catalog Number

CopperTen Disconnection Module, 8 pair

6468 5 070-00

BX (Box=10 each)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

111

Copper Connectivity Solutions Category 6a UTP

Up to 750
Up to 200
TIA/EIA 568-B.2-1, TIA/EIA 568-B.2-10
standard Category 6a
ISO/IEC 11801 Class F

11/11

102094AE

TrueNet Structured Cabling

Specifications

Copper Connectivity Solutions


Category 6a UTP
CopperTen Modular Jack

Ordering Information
Description

Catalog Number*

CopperTen RJ45 UTP modular 568A/B jack


Quantity: 1

6830 1 835-XX

Replace XX with:

01
02
03
04
05
22

=
=
=
=
=
=

White
06
Ivory
07
Gray
08
Black
09
Red
10
Electrical Ivory

=
=
=
=
=

Blue
Green
Yellow
Purple
Orange

102094AE

TrueNet Structured Cabling

Meets or exceeds performance requirements of TIA/EIA 568-B.2-10 standards


45-degree silver-plated IDCs provide secure,
reliable gas-tight connections
Accepts KRONE or 110 tool for wire
termination
Universal A/B wiring label
Modular jacks fit port openings of
0.585" x 0.757" (14.86mm x 19.23mm)
with plate thickness from 0.048" to 0.060"
(1.23mm x 1.52mm)

7/08

Copper Connectivity Solutions Category 6a UTP

Features

www.te.com/adc

+1-952-938-8080

1-800-366-3891

112

Copper Connectivity Solutions


Category 6a UTP
CopperTen Patch Cords

Meets or exceeds performance requirements


TIA/EIA 568-B.2-10 standards
Copper conductors in the cable pairs
are stranded for superior flexibility and
compacted to a near-round shape for
optimum signal strength
Snag-less plug design with built-in
strain relief
UL 1863 safety rating

Ordering Information
Description

Catalog Number*

568B wiring

6645-2-8X5-YY

568A wiring

6645-2-8X0-YY

Copper Connectivity Solutions Category 6a UTP

RJ45 to RJ45 patch cord

*Replace X for color:


0 = White
3 = Yellow
1 = Red
4 = Green
2 = Blue
6 = Gray
*Replace YY for length:
04 = 4'

15 = 15'

07 = 7'

25 = 25'

10 = 10'

50 = 50"

Contact TE for information on additional colors and


custom lengths

11/11

102094AE

TrueNet Structured Cabling

Features

www.te.com/adc

+1-952-938-8080

1-800-366-3891

113

Copper Connectivity Solutions


Category 6a UTP

TrueNet Structured Cabling


102094AE

Impedance matched for use in TrueNet structured


cabling systems; these CopperTen termination
block patch cords exceed all performance
requirements for Augmented Category 6. These
cords allow direct patching capability between
CopperTen 8-pair and 20-pair blocks or patching
from a CopperTen termination block to an
active device or an RJ45 patch panel. The plug
is designed with integrated strain relievers that
prevent the cable from moving at the termination
point when the cable is flexed, safeguarding
circuit integrity and guaranteeing maximum
performance.

Features

Meets or exceeds TIA/EIA and ISO Augmented Category 6 requirements


Protective shroud to assist in protecting the user from electrical transfer on the contacts
Impedance matched patch cord for maximum throughput
Flexible strain relief boot maintains proper bend radius to ensure peak performance
UL 1863 listed
Durable design to be in operation beyond 20-year product warranty

Specifications
Environment for use:
Operation temperature range:
Maximum relative humidity:
Insulation resistance:
Flammability rating of plastic housing:
No: of PCB insertion cycles:
Plug Material:
Safety:

Indoors, in dry closed rooms


-10C to + 60C
93% non-condensing
100M at 500 VDC
UL 94 V0change
Typically 200
Tough Thermoplastic Polymer
UL1863

11/11

Copper Connectivity Solutions Category 6a UTP

Augmented Category 6 Patch Cords


For CopperTen 8-pair and 20-pair Termination Blocks

www.te.com/adc

+1-952-938-8080

1-800-366-3891

114

Copper Connectivity Solutions


Category 6a UTP

Augmented Category 6 Patch Cords


For CopperTen 8-pair and 20-pair Termination Blocks
Ordering Information
Catalog Number

CopperTen 4-pair to CopperTen 4-Pair


CopperTen 4-Pair to CopperTen 4-Pair wired 568B

TP6ATH-XXYY

CopperTen 4-Pair to CopperTen 4-Pair wired 568A

TP6ATH0XXYY

CopperTen 4-pair to RJ45


CopperTen 4-Pair to RJ45 Plug wired 568B

TP6ATB-XXYY

CopperTen 4-Pair to RJ45 Plug wired 568A

TP6ATB0XXYY

Copper Connectivity Solutions Category 6a UTP

Sub XX for color: BL=Blue, BK=Black, GY=Gray, RD=Red, GN=Green, YL=Yellow, WT=White
Call TE for additional colors
Sub YY for length: 04= 4 feet, 07= 7 feet, 10=10 feet, 15=15 Feet, 25=25 feet, 50=50 feet
Call TE for additional lengths

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

115

Copper Connectivity Solutions


Category 6a UTP
CopperTen 4-Port Staggered Faceplate

TrueNet Structured Cabling

CopperTen 4-port Staggered Faceplate


shown with CopperTen Modular Jacks

Applications
Workstation mounting platform for modular
voice, video and data connectors
delivering high performance solutions

Ordering Information
Description

Catalog Number*

CopperTen 4-port staggered faceplate

TNSCSFPSO4-XX

Includes: 2 blank paper labels, 2 clear plastic


protectors, 1 logo insert, 6 reversible ID tabs
numbered 16 (ID tabs match faceplate colors),
mounting screws (#6-32 x 15/16")
*Replace XX with:
WT = White, IV = Ivory, GY = Grey, BK = Black

102094AE

Unique staggered four-port design


supports 10 Gigabit Ethernet performance
by countering the negative effects of
alien crosstalk
Fits standard single gang box
UL 1863 listed
Increases workstation density in a single
gang mounting platform while optimizing
Augmented Category 6 performance

11/11

Copper Connectivity Solutions Category 6a UTP

Features and Benefits

www.te.com/adc

+1-952-938-8080

1-800-366-3891

116

Copper Connectivity Solutions


Category 6a UTP
CopperTen 6-Port Surface Mount Box

Unique six-port design supports 10 Gigabit


Ethernet performance by countering the
negative effects of alien crosstalk
Fits standard single gang box or any furniture raceway opening
Knockouts allow cable and raceway access
UL 1863 listed
Increases workstation density in a single
gang mounting platform while optimizing
Augmented Category 6 performance
Six-port surface mount box design allows
proper bend radius for Augmented
Category 6 cables

CopperTen 6-port surface mount box


shown with CopperTen Modular Jacks

Copper Connectivity Solutions Category 6a UTP

Applications
Workstation mounting platform for modular
voice, video and data connectors delivering
high performance solution

Ordering Information
Description

Catalog Number*

CopperTen 6-port surface mount box

TNSCSSB6-XX

Includes: 2 blank paper labels, 2 clear plastic


protectors, 1 logo insert, 6 reversible ID tabs
numbered 16 (ID tabs match faceplate color),
1 hook-and-loop fastener strip, 1 millie tie for
cable management, 2 mounting screws
(#6-32 x 15/16")

*Replace XX with:
WT = White, IV = Ivory, GY = Grey, BK = Black

11/11

102094AE

TrueNet Structured Cabling

Features and Benefits

www.te.com/adc

+1-952-938-8080

1-800-366-3891

117

Introduction ................................................................... 120


CopperTen F/UTP Horizontal Cable................................ 121
CopperTen F/UTP Patch Panels...................................... 129
CopperTen F/UTP Modular Jack .................................... 130

Copper Connectivity Solutions Category 6a F/UTP

CopperTen F/UTP Patch Cords ...................................... 131

11/11

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions


Category 6a F/UTP

www.te.com/adc

+1-952-938-8080

1-800-366-3891

119

Copper Connectivity Solutions


Category 6a F/UTP

TrueNet Structured Cabling

Features
Exceeds the requirements of IEEE 802.3an (10GBASE-T) and ISO/IEC 11801:2002 amendment/channel
requirements
Maximizes productivity levels with 10 times the data throughput of Category 6
True future proofing for tomorrow's network applications
Covered by the TrueNet System Warranty

102094AE

The TrueNet CopperTen F/UTP Solution


supports 10 Gigabit Ethernet to a full 100m.
At high frequencies associated with 10 Gigabit
per second transmission speeds alien crosstalk
(interference between adjacent cables) hinders
performance. The shielding used in the
CopperTen F/UTP solution effectively eliminates
all alien crosstalk allowing data transmission rates
of 10 Gigabits per second.

11/11

Copper Connectivity Solutions Category 6a F/UTP

Introduction

www.te.com/adc

+1-952-938-8080

1-800-366-3891

120

Copper Connectivity Solutions


Category 6a F/UTP

TE F/UTP CopperTen cable can be used in data


center, communications closet and work station
for 10G shielded performance. Installed in highperformance networks world wide, the systems
design minimizes alien crosstalk and insertion loss
and meets the performance requirements of IEEE
802.3an and TIA 568-B.2-10 standards.

Features
Supports 10 Gigabit Ethernet over shielded
copper to a full 100 meters
Covered by the 20 year TrueNet CopperTen
warranty

Common Applications

4/16 Mb/s Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-Any LAN (IEEE 802.12)
52/155 Mb/s ATM (ATM Forum)
622 Mb/s ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
1.2 Gb/s ATM (ATM Forum)
77 Channel Broadband Video
10GBASE-T Ethernet (IEEE P802.3an)

Copper Connectivity Solutions Category 6a F/UTP

11/11

102094AE

TrueNet Structured Cabling

CopperTen Four-Pair F/UTP Plenum Cable

Compliances

UL Subject 444
(UL)-C(UL) Type CMP
ICEA S-90-661
NEC 800 Type CMP
TIA/EIA-568-B.2-1 Category 6 Horizontal
Cable Requirements
ETL Verified TIA/EIA-568-B.2-10 Augmented
Category 6 Horizontal Cable Requirements
ISO/IEC 11801 Category 6 Horizontal Cable
Requirements
ISO/IEC 11801 Category 6a Class EA
Horizontal Cable Requirements

www.te.com/adc

+1-952-938-8080

1-800-366-3891

121

Copper Connectivity Solutions


Category 6a F/UTP
CopperTen Four-Pair F/UTP Plenum Cable

TrueNet Structured Cabling

23 AWG solid bare copper


Foamed FEP
Fluoropolymer
Aluminum/polyester foil
Stranded tinned copper
Lead-free, flame retardant PVC
.285" (7.2mm)

THERMAL CHARACTERISTICS:
Transport and Storage:
Installation:
Operation:

-10C to 60C
4C to 50C
-10C to 60C

MECHANICAL CHARACTERISTICS:
Bend Radius
During Installation:
Installed:
Pull Tension:

16 X O.D.
8 X O.D.
25 lb/f (110N)

ELECTRICAL CHARACTERISTICS:
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


5%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
72%

102094AE

CONSTRUCTION:
Conductor:
Insulation:
Separator:
Shield:
Drain Wire:
Jacket:
Nominal O.D.:

11/11

Copper Connectivity Solutions Category 6a F/UTP

Specifications

www.te.com/adc

+1-952-938-8080

1-800-366-3891

122

Copper Connectivity Solutions


Category 6a F/UTP
Fitted
Impedance

Insertion Loss

Return Loss

Pair-Pair NEXT

PSNEXT

MHZ

Ohms

dB/100m

dB/100m

dB/100m

dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

Min

Spec

100 +/- 15

1.7

24.3

20

85.9

74.3

83.2

72.3

100 +/- 15

3.4

3.7

27.1

23

75.9

65.3

73

63.3

100 +/- 15

4.8

5.2

29.4

24.5

68.6

60.8

65.4

58.8

10

100 +/- 15

5.4

5.9

31

25

61.5

59.3

59.1

57.3

16

100 +/- 15

6.8

7.4

30.4

25

63.6

56.2

62.7

54.2

20

100 +/- 15

7.6

8.3

31.6

25

65.4

54.8

62.7

52.8

25

100 +/- 15

8.6

9.3

33.1

24.3

62.6

53.3

58.6

51.3

31.25

100 +/- 15

9.7

10.4

34.2

23.6

67.1

51.9

63.5

49.9

62.5

100 +/- 15

13.9

14.9

31.1

21.5

54

47.4

52.5

45.4

100

100 +/- 15

17.9

19

28.9

20.1

52.7

44.3

50.7

42.3

155

100 +/- 15

22.6

24

33

18.8

45.3

41.4

44.7

39.4

200

100 +/- 15

26.1

27.5

23.5

18

50.7

39.8

48.7

37.8

250

100 +/- 15

29.4

31

22.9

17.3

42.3

38.3

41.1

36.3

300

100 +/- 15

32.7

34.2

26.2

16.8

43.1

37.1

40.5

35.1

350

100 +/- 15

35.8

37.2

22.9

16.3

45.2

36.1

42.2

34.1

400

100 +/- 15

38.7

40

21.9

15.9

44.7

35.3

41.4

33.3

450

100 +/- 15

41.5

42.7

22.4

15.5

39.2

34.5

37.8

32.5

500

100 +/- 15

44.1

45.3

20.1

15.2

36.7

33.8

35.2

31.8

550

100 +/- 15

46.9

21.7

39.9

38.6

600

100 +/- 15

49.5

17

36.6

34.4

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

123

Copper Connectivity Solutions Category 6a F/UTP

FREQ

102094AE

TrueNet Structured Cabling

CopperTen Four-Pair F/UTP Plenum Cable

Copper Connectivity Solutions


Category 6a F/UTP
CopperTen Four-Pair F/UTP Plenum Cable
FREQ

Pair-Pair ACR

PSACR

Pair-Pair ELFEXT

PSNEXT

MHZ

dB/100m

dB/100m

dB/100m

dB/100m

TrueNet Structured Cabling


102094AE

Spec

Min

Spec

Min

Spec

Min

Spec

Spec

84.2

72.3

81.5

70.3

83.8

67.8

83.1

64.8

40.0

72.7

61.5

69.8

59.5

75.8

55.8

75.2

52.8

40.0

64.1

55.5

60.9

53.5

64.2

49.7

62.5

46.7

40.0

10

56.5

53.4

54.0

51.4

64.0

47.8

60.3

44.8

40.0

16

57.2

48.8

56.3

46.8

63.7

43.7

61.2

40.7

38.0

20

58.1

46.5

55.1

44.5

59.9

41.8

58.4

38.8

37.0

25

54.4

44.0

50.4

42.0

57.5

39.8

56.9

36.8

36.0

31.25

57.5

41.5

53.8

39.5

55.4

37.9

55.6

34.9

35.1

62.5

40.8

32.5

39.3

30.5

52.4

31.9

50.6

28.9

32.0

100

35.7

25.3

33.4

23.3

52.9

27.8

51.1

24.8

30.0

155

23.7

17.5

22.1

15.5

45.4

24.0

43.8

21.0

28.1

200

25.8

12.3

23.8

10.3

46.0

21.8

43.4

18.8

27.0

250

14.2

7.4

12.5

5.4

43.0

19.8

41.0

16.8

26.0

300

11.9

3.0

9.3

1.0

43.0

18.3

39.3

15.3

350

11.0

-1.0

8.1

-3.0

39.0

16.9

38.3

13.9

400

7.5

-4.7

3.4

-6.7

37.5

15.8

35.7

12.8

450

-0.7

-8.2

-2.2

-10.2

38.9

14.7

36.2

11.7

500

-5.7

-11.4

-7.2

-13.4

39.5

13.8

35.4

10.8

550

-5.6

-6.9

31.9

32.3

600

-12.9

-14.4

31.2

29.2

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA-568-B.2-10 specification.

Ordering Information
Description

Catalog Number

1000 foot reel, 42lbs 62kg

10G-A6TPF-XX02

NOTES: XX = Jacket color - BL = Blue, WT = White, GY = Gray

11/11

Copper Connectivity Solutions Category 6a F/UTP

Max

TCL

www.te.com/adc

+1-952-938-8080

1-800-366-3891

124

Copper Connectivity Solutions


Category 6a F/UTP

TE F/UTP CopperTen cable can be used in data


center, communications closet and work station
for 10G shielded performance. Installed in highperformance networks world wide, the systems
design minimizes alien crosstalk and insertion loss
and meets the performance requirements of IEEE
802.3an and TIA 568-B.2-10 standards.

Features
Supports 10 Gigabit Ethernet over shielded
copper to a full 100 meters
20 year TrueNet CopperTen warranty

Common Applications

4/16 Mb/s Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-Any LAN (IEEE 802.12)
52/155 Mb/s ATM (ATM Forum)
622 Mb/s ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1 Gigabit Networking System (WGNA)
1.2 Gb/s ATM (ATM Forum)
77 Channel Broadband Video
10GBASE-T Ethernet (IEEE P802.3an)

Copper Connectivity Solutions Category 6a F/UTP

11/11

102094AE

TrueNet Structured Cabling

CopperTen Four-Pair F/UTP Riser Cable

Compliances

UL Subject 444
(UL)-C(UL) Type CMR
ICEA S-90-661
NEC 800 Type CMR
TIA/EIA-568-B.2-1 Category 6 Horizontal
Cable Requirements
ETL Verified TIA/EIA-568-B.2-10 Augmented
Category 6 Horizontal Cable Requirements
ISO/IEC 11801 Category 6 Horizontal Cable
Requirements
ISO/IEC 11801 Category 6a Class EA
Horizontal Cable Requirements

www.te.com/adc

+1-952-938-8080

1-800-366-3891

125

Copper Connectivity Solutions


Category 6a F/UTP
CopperTen Four-Pair F/UTP Riser Cable

TrueNet Structured Cabling

23 AWG solid bare copper


HDPE
HDPE
Aluminum/polyester foil
Stranded tinned copper
Lead-free, flame retardant PVC
.280" (7.1mm)

THERMAL CHARACTERISTICS:
Transport and Storage:
Installation:
Operation:

-10C to 60C
4C to 50C
-10C to 60C

MECHANICAL CHARACTERISTICS:
Bend Radius
During Installation:
Installed:
Pull Tension:

16 X O.D.
8 X O.D.
25 lb/f (110N)

ELECTRICAL CHARACTERISTICS:
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


5%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
72%

102094AE

CONSTRUCTION:
Conductor:
Insulation:
Separator:
Shield:
Drain Wire:
Jacket:
Nominal O.D.:

11/11

Copper Connectivity Solutions Category 6a F/UTP

Specifications

www.te.com/adc

+1-952-938-8080

1-800-366-3891

126

Copper Connectivity Solutions


Category 6a F/UTP
Fitted
Impedance

Insertion Loss

Return Loss

Pair-Pair NEXT

PSNEXT

MHZ

Ohms

dB/100m

dB/100m

dB/100m

dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

Min

Spec

100 +/- 15

1.7

2.0

24.3

20.0

85.9

74.3

83.2

72.3

100 +/- 15

3.4

3.7

27.1

23.0

75.9

65.3

73.0

63.3

100 +/- 15

4.8

5.2

29.4

24.5

68.6

60.8

65.4

58.8

10

100 +/- 15

5.4

5.9

31.0

25.0

61.5

59.3

59.1

57.3

16

100 +/- 15

6.8

7.4

30.4

25.0

63.6

56.2

62.7

54.2

20

100 +/- 15

7.6

8.3

31.6

25.0

65.4

54.8

62.7

52.8

25

100 +/- 15

8.6

9.3

33.1

24.3

62.6

53.3

58.6

51.3

31.25

100 +/- 15

9.7

10.4

34.2

23.6

67.1

51.9

63.5

49.9

62.5

100 +/- 15

13.9

14.9

31.1

21.5

54.0

47.4

52.5

45.4

100

100 +/- 15

17.9

19.0

28.9

20.1

52.7

44.3

50.7

42.3

155

100 +/- 15

22.6

24.0

33.0

18.8

45.3

41.4

44.7

39.4

200

100 +/- 15

26.1

27.5

23.5

18.0

50.7

39.8

48.7

37.8

250

100 +/- 15

29.4

31.0

22.9

17.3

42.3

38.3

41.1

36.3

300

100 +/- 15

32.7

34.2

26.2

16.8

43.1

37.1

40.5

35.1

350

100 +/- 15

35.8

37.2

22.9

16.3

45.2

36.1

42.2

34.1

400

100 +/- 15

38.7

40.0

21.9

15.9

44.7

35.3

41.4

33.3

450

100 +/- 15

41.5

42.7

22.4

15.5

39.2

34.5

37.8

32.5

500

100 +/- 15

44.1

45.3

20.1

15.2

36.7

33.8

35.2

31.8

550

100 +/- 15

46.9

21.7

39.9

38.6

600

100 +/- 15

49.5

17.0

36.6

34.4

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

127

Copper Connectivity Solutions Category 6a F/UTP

FREQ

102094AE

TrueNet Structured Cabling

CopperTen Four-Pair F/UTP Riser Cable

Copper Connectivity Solutions


Category 6a F/UTP
CopperTen Four-Pair F/UTP Riser Cable
FREQ

Pair-Pair ACR

PSACR

Pair-Pair ELFEXT

PSNEXT

MHZ

dB/100m

dB/100m

dB/100m

dB/100m

TrueNet Structured Cabling

Min

Spec

Min

Spec

Min

Spec

Spec

84.2

72.3

81.5

70.3

83.8

67.8

83.1

64.8

40.0

72.7

61.5

69.8

59.5

75.8

55.8

75.2

52.8

40.0

64.1

55.5

60.9

53.5

64.2

49.7

62.5

46.7

40.0

10

56.5

53.4

54.0

51.4

64.0

47.8

60.3

44.8

40.0

16

57.2

48.8

56.3

46.8

63.7

43.7

61.2

40.7

38.0

20

58.1

46.5

55.1

44.5

59.9

41.8

58.4

38.8

37.0

25

54.4

44.0

50.4

42.0

57.5

39.8

56.9

36.8

36.0

31.25

57.5

41.5

53.8

39.5

55.4

37.9

55.6

34.9

35.1

62.5

40.8

32.5

39.3

30.5

52.4

31.9

50.6

28.9

32.0

100

35.7

25.3

33.4

23.3

52.9

27.8

51.1

24.8

30.0

155

23.7

17.5

22.1

15.5

45.4

24.0

43.8

21.0

28.1

200

25.8

12.3

23.8

10.3

46.0

21.8

43.4

18.8

27.0

250

14.2

7.4

12.5

5.4

43.0

19.8

41.0

16.8

26.0

300

11.9

3.0

9.3

1.0

43.0

18.3

39.3

15.3

350

11.0

-1.0

8.1

-3.0

39.0

16.9

38.3

13.9

400

7.5

-4.7

3.4

-6.7

37.5

15.8

35.7

12.8

450

-0.7

-8.2

-2.2

-10.2

38.9

14.7

36.2

11.7

500

-5.7

-11.4

-7.2

-13.4

39.5

13.8

35.4

10.8

550

-5.6

-6.9

31.9

32.3

600

-12.9

-14.4

31.2

29.2

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA-568-B.2-10 specification.

Ordering Information
Description

Catalog Number

1000 foot reel, 41lbs 61kg

10G-A6TRF-XX02

NOTES: XX = Jacket color - BL = Blue, WT = White, GY = Gray

102094AE

Spec

11/11

Copper Connectivity Solutions Category 6a F/UTP

Max

TCL

www.te.com/adc

+1-952-938-8080

1-800-366-3891

128

Copper Connectivity Solutions


Category 6a F/UTP

TE's F/UTP CopperTen patch panels can be


used in data center, communications closet and
workstation for 10G shielded performance.
Installed in high-performance networks world
wide, the systems design minimizes alien
crosstalk and insertion loss and meets the
performance requirements of IEEE 802.3an and
TIA 568-B.2-10 standards.

Features
Mounts in standard EIA 19-inch (482. 6mm) rack
Designed specifically to be used with TE Augmented Category 6 shielded jack

Specifications
Operating Temperature Range:
Safety Rating:
Flammability Rating:

Ordering Information
Description

Catalog Number

CopperTen Augmented Category 6 F/UTP Patch Panels


1U Patch Panel, Category 6 KM8 shielded 24 ports

7022 1 155-24

1U Patch Panel, Category 6 KM8 shielded 24 ports (unloaded)

7022 2 155-24

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

129

Copper Connectivity Solutions Category 6a F/UTP

-40 C to 70 C (-40 F to 158 F)


UL 1863
UL 94-V0

102094AE

TrueNet Structured Cabling

CopperTen Augmented Category 6 F/UTP Patch Panels

Copper Connectivity Solutions


Category 6a F/UTP

TrueNet Structured Cabling

Features
TrueNet impedance matched jacks guarantee maximum throughput
Forty-five degree silver-plated IDCs provide secure, reliable gas-tight connections
Universal A/B wiring label

Specifications
Operating Temperature Range:
RJ Socket, 8 Positions, General Specification:
Transmission Performance and Reliability:
Number of Plug Insertion Cycles:
LSA-PLUS Insulation Displacement
Wire Diameter Range for Solid and 22-24 AWG
Stranded Copper Conductors:
Wire Insulation Diameter Range (PE,PVC):
Contact Resistance:
Contact Re-terminations:
Insulation Resistance at 40 C (104 F) and 93% RH:
Safety Rating:
Flammability Rating:

-40 to 70 C (-40 to 158 F)


FCC Part 68.500 (IEC 603-7)
EIA/TIA 568-B.2-10 standard
750 (IEC/EN 60603-7)
0.50 mm to 0.65 mm (0.016" to 0.025")
1.04 mm to 1.60 mm (0.041" to 0.063")
1 m typical
200
500 M (IEC 512-2-3a)
UL 1863
UL 94 V-0

Ordering Information

102094AE

TE shielded CopperTen jacks can be used in data


center, communications closet and work station
for 10G shielded performance. Installed in highperformance networks world wide, the systems
design minimizes alien crosstalk and insertion loss
and meets the performance requirements of IEEE
802.3an and TIA 568-B.2-10 standards.

Description

Catalog Number

11/11

Copper Connectivity Solutions Category 6a F/UTP

CopperTen Augmented Category 6 Shielded RJ45 Jack

C6a shielded 568A/B RJ45 jack

6830 1 811-XX

Substitute XX for jack colors- 01=White, 02=Ivory, 03=Gray and 04=Black. Call TE for other colors

www.te.com/adc

+1-952-938-8080

1-800-366-3891

130

Copper Connectivity Solutions


Category 6a F/UTP

TE F/UTP CopperTen patch cords can be used


in data center, communications closet and work
station for 10G shielded performance. Installed
in high-performance networks world wide,
the systems design minimizes alien crosstalk
and insertion loss and meets the performance
requirements of IEEE 802.3an and TIA 568-B.2-10
standards.
The high performance plug design with
integrated strain relief boot prevents the cable
from being moved at the termination point when
the cable is flexed. The strain relief boot also
ensures that correct bend radius is maintained.

Features
Supports 10 Gigabit Ethernet over shielded copper to a full 100 meters
Snag less plug design with integrated strain relief
20 year TrueNet CopperTen warranty

Specifications
Operating Temperature Range:
RJ45 Plug Interface According to:
Transmission Performance and Reliability:
Number of Plug Insertion Cycles:
Conductor:
Jacket:
Bend Radius:
Nominal Outer Diameter:
Safety Rating:
Flammability Rating:

-20 to 75 C (-4 to 167F)


IEC 60603-7
TIA/IEA 568-B.2-10 standards
750 (IEC/EN 60603-7)
26 AWG 7x32 stranded tinned copper
Lead-free PVC
2 x outer diameter
7.239 mm .13 mm (0.285" 0.005")
UL 1863
UL 94 V-0

Ordering Information
Description

Catalog Number

F/UTP RJ45 to RJ45 Patch Cords


Blue

TP10GTF-BLXX

White

TP10GTF-WTXX

Gray

TP10GTF-GYXX

Sub XX for length. 04= 4 feet, 07= 7 feet, 10=10 feet, 15=15 Feet, 25=25 feet, 50=50 feet

www.te.com/adc

+1-952-938-8080

1-800-366-3891

131

Copper Connectivity Solutions Category 6a F/UTP

11/11

102094AE

TrueNet Structured Cabling

CopperTen Augmented Category 6 F/UTP Patch Cords

Category 6 Copper Cable .............................................. 135


Patch Panels .................................................................. 147
Termination Blocks ......................................................... 153
Modular Jacks ................................................................ 158
Patch Cords ................................................................... 159

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

133

Copper Connectivity Solutions Category 6

Introduction ................................................................... 134

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions


Category 6

Copper Connectivity Solutions Category 6


TrueNet Category 6
RJ45 Modular Solution

TE Ultim8 and HighBand 25 blocks provide


unparalleled patching and testing capabilities that
provide ultimate flexibility in deploying a network.
HighBand 25 and Ultim8 blocks provide a crossconnection system with greater density, front side
termination and fewer patch cords. There are
multiple mounting options available to support both
rack and wall mount application to maximize your
telecommunications room real estate requirements.
The Ultim8 and HighBand 25 blocks also feature
a unique center port that acts as a test port to
provide look-both-ways testing capability without
the removal of any wire. This port also allows simple
circuit monitoring through use of a test cord.
TrueNet Category 6 products deliver exceptional
system performance by including features that
protect signal integrity and strength. The IEEE
specifications for signal amplitude are especially
important for Gigabit Ethernet (which uses
multilevel encoding).
In addition, these features may also enable lower
voltage NIC cards to transmit a clean signal.

TrueNet Cable
Hub Switch

Category 6
Patch Panel

KM8
Jacks

TrueNet
Patch Cord

TrueNet Patch Cord

TrueNet Category 6
IDC Block Solution
TrueNet Cable

Hub Switch

HighBand
Ultim8
Blocks

KM8
Jacks

TrueNet
Patch Cord

TrueNet Patch Cord

Mismatched Signal Amplitude

Volts

TrueNet patch panels are manufactured in 24-port


(1RU) or 48-port (2RU) configurations to provide
high-density modular patching solutions for all
high-density applications where space is limited.
The LSA-PLUS IDC technology provides a secure,
reliable and gas-tight connection and allows for
the wire to be terminated with either a KRONE
insertion tool or a 110 termination tool.

Time
The mismatched channel allows signal
amplitude to fall out of IEEE specifications.

TrueNet Category 6 solutions deliver:


A complete end-to-end channel

TrueNet Signal Amplitude

Zero bit errors


ISO/IEC 11801, Class E compliance

Volts

Extra bandwidth, better attenuation

102094AE

TrueNet Structured Cabling

TEs TrueNet Category 6 patch panels, patch cords,


modular jacks, and cable form an
end-to-end channel optimized to preserve signal
amplitude and deliver zero-bit-error performance
in Gigabit Ethernet applications.

11/11

Copper Connectivity Solutions Category 6

Introduction

ANSI/EIA/TIA-568-B.2-1 Category 6
compliance
Time
The TrueNet channel preserves signal
amplitude within IEEE specifications.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

134

Copper Cable Solutions


Category 6 Copper Cable
Category 6 Plenum Cable

TrueNet Category 6 Plenum cable


is protected by US Patents 6153826

TrueNet Category 6 Plenum cable


is also available in a side-by-side configuration

Common Applications

Compliances

4/16Mbps Token Ring (IEEE 802.5)

UL Subject 444

10Base-T (IEEE 802.3)

(UL)-C(UL) Type CMP

100Mbps TP-PMD

ICEA S-90-661

Broadband and baseband video

NEC 800 Type CMP

100Base-T (Fast Ethernet)

ISO/IEC 11801 Class E

100Base-T4 (Fast Ethernet)

TIA/EIA-568-B.2-1 Category 6 horizontal


cable requirements

100Base-TX (Fast Ethernet)


100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)

11/11

102094AE

1Gbps Networking System (WGNA)


1.2Gbps ATM (ATM Forum)
77 Channel broadband video

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Pairing:
Filler:
Color-coding:
Jacket:

24 AWG solid bare copper


100% FEP
Short, staggered pair lays
Fluoropolymer
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

135

Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Copper Cable Solutions


Category 6 Copper Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 6

Category 6 Plenum Cable


Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
FITTED
FREq IMPEDANCE
(MHz)
(Ohms)
SPEC
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550
FREq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

5
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
25 nS/100 meters @100MHz
75%

INSERTION LOSS
(dB/100m)

RETURN LOSS
(dB/100m)

Max

TIA Spec

Min

TIA Spec

Min

TIA Spec

Min

TIA Spec

1.7
3.4
4.9
5.5
7.0
7.9
8.9
9.9
14.3
18.4
23.3
26.8
30.4
33.7
36.7
39.6
42.5
45.3
47.7

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

28.5
32.1
35.0
34.6
31.7
32.1
36.5
36.7
34.0
30.8
27.3
31.0
28.6
27.2
24.3
25.0
24.5
24.2
18.6

20.0
22.9
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

83.8
74.9
74.4
70.3
67.2
66.8
65.6
61.8
61.0
60.2
54.8
54.9
49.5
49.0
46.3
47.5
47.3
43.8
40.2

74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
41.4
39.8
38.3

81.9
74.3
71.0
68.0
66.7
64.7
63.6
60.9
59.3
57.4
51.4
52.4
48.5
48.2
44.8
45.2
43.4
43.0
39.4

72.3
63.3
58.8
57.3
54.2
52.8
51.3
49.9
45.4
42.3
39.4
37.8
36.3

Pair-Pair ACR
(dB/100m)

PSACR
(dB/100m)

Min

TIA Spec

Min

TIA Spec

86.8
71.7
69.8
65.1
64.8
59.4
60.2
52.5
49.3
42.7
33.2
30.3
26.7
19.4
16.8
12.0
10.4
8.8
1.7

72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

84.2
71.2
66.4
62.8
61.5
57.4
57.7
51.3
47.9
41.6
29.9
26.9
22.2
16.6
14.7
10.2
8.4
4.8
0.7

70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

Pair-Pair NExT
(dB/100m)

Pair-Pair ELFExT
(dB/100m)
Min

TIA Spec

73.6
62.7
57.2
55.2
51.1
49.3
47.4
45.5
40.1
36.8
33.6
31.7
29.1
26.2
21.3
22.1
28.3
23.6
25.7

67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
24.0
21.8
19.8

PSNExT
(dB/100m)

PSELFExT
(dB/100m)
Min
72.6
61.8
56.2
54.2
49.8
48.2
46.5
44.4
39.4
35.9
33.2
30.6
28.9
25.5
21.8
22.5
27.3
24.0
24.7

LCL
(dB/100m)

TIA Spec

Min

64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
21.0
18.8
16.8

40.0
40.0
40.0
40.0
38.0
37.0
36.0
35.1
32.0
30.0
28.1
27.0
26.0

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

136

Copper Cable Solutions


Category 6 Copper Cable

Ordering Information
Weight (Lbs/kft)

Catalog Number*

4-pair cable
Nominal OD: 0.208" (5.28mm)
Maximum OD: 0.212" (5.38mm)
Reel packaging1000'

30

TN6SP-XX02

Reel in a box1000'

32

TN6SP-XXRB

4-pair side-by-side cable


Nominal OD: 0.22" x 0.45" (5.6mm x 11.43mm)

76

TN6SPX2-XXYY

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
Other reel sizes available, please contact TE Customer Service.

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

137

Copper Connectivity Solutions Category 6

Category 6 Plenum Cable

Copper Cable Solutions


Category 6 Copper Cable
Category 6 Riser Cable

102094AE

TrueNet Structured Cabling

Common Applications

11/11

Copper Connectivity Solutions Category 6

4/16Mbps Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)

TrueNet Category 6 riser cable is protected


by US Patents 6153826 and 6150612

100VG-AnyLAN (IEEE 802.12)


52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)
1.2Gbps ATM (ATM Forum)
77 Channel broadband video

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR
ISO/IEC 11801 Category 6
ETL Verified TIA/EIA-568-B.2-1 Category 6
horizontal cable requirements

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Filler:
Color-coding:
Jacket:

24 AWG solid bare copper


100% Polyolefin
Short, staggered pair lays
polyolefin
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

138

Copper Cable Solutions


Category 6 Copper Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

FREq
(MHz)

FITTED
IMPEDANCE
(Ohms)
SPEC

Max

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550

100 5
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3
100 3

1.8
3.6
5.1
5.8
7.4
8.3
9.3
10.4
14.9
19.0
24.0
27.4
30.8
33.9
36.6
39.4
42.3
44.8
47.1

FREq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
450
500
550

INSERTION
LOSS
(dB/100m)

Pair-Pair ACR
(dB/100m)
Min
81.8
74.4
60.6
61.6
63.5
54.3
53.4
52.0
42.2
37.0
29.0
23.3
19.8
10.8
9.8
5.9
6.7

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
25 nS/100 meters @100MHz
69%

TIA
Spec
72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

RETURN LOSS
(dB/100m)

Pair-Pair NExT
(dB/100m)

TIA Spec

Min

TIA Spec

Min

TIA Spec

Min

TIA Spec

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

27.2
32.2
34.2
33.8
33.9
30.6
33.1
32.9
33.5
29.4
23.5
27.1
27.9
23.3
21.5
22.1
20.4
18.5
18.3

20.0
22.9
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

83.4
76.9
65.6
67.2
65.9
62.2
60.1
60.6
54.0
54.4
52.2
49.9
50.1
44.1
45.9
44.8
45.8
41.6
41.1

74.3
65.3
60.8
59.3
56.2
54.8
53.3
51.9
47.4
44.3
41.4
39.8
38.3

81.0
73.7
64.0
65.7
63.8
61.1
59.9
58.5
53.1
52.3
50.5
47.6
47.7
42.6
45.2
41.9
42.5
40.0
38.8

72.3
63.3
58.8
57.3
54.2
52.8
51.3
49.9
45.4
42.3
39.4
37.8
36.3

PSACR
(dB/100m)
Min
79.3
72.9
59.2
60.1
60.3
53.2
51.9
51.8
41.4
35.9
27.2
21.0
17.4
9.2
9.1
4.8
3.7

TIA
Spec
70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

Pair-Pair ELFExT
(dB/100m)
Min
75.4
63.0
56.0
54.7
50.4
49.8
47.3
46.0
40.3
37.2
35.2
35.7
32.1
27.0
24.9
23.7
22.3
19.9
15.4

TIA
Spec
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
24.0
21.8
19.8

PSELFExT
(dB/100m)
Min
74.8
62.5
55.6
54.7
50.5
49.8
47.1
45.9
40.3
37.1
34.6
32.0
31.5
25.5
23.8
21.2
19.5
18.7
15.4

TIA
Spec
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
21.0
18.8
16.8

PSNExT
(dB/100m)

LCL
(dB/100m)

ISO
SPEC

TIA
Spec

ELTCTL Min
(dB)

40.0
40.0
40.0
40.0
38.0
37.0
36.0
35.1
32.0
30.0
28.1
27.1
26.0

35.0
23.0
16.9
15.0
10.9
9.0
7.0
5.1

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

139

Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Category 6 Riser Cable


Specifications

Copper Cable Solutions


Category 6 Copper Cable

Ordering Information
Weight (Lbs/kft)

Catalog Number*

4-pair cable
Nominal OD: 0.206" (5.4mm)
Reel packaging1000'

26

TN6SR-XX02

Reel in a box1000'

28

TN6SR-XXRB

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
Other reel sizes available, please contact TE Customer Service.

102094AE

TrueNet Structured Cabling

Description

11/11

Copper Connectivity Solutions Category 6

Category 6 Riser Cable

www.te.com/adc

+1-952-938-8080

1-800-366-3891

140

Copper Cable Solutions


Category 6 Copper Cable

Category 6 Bundled Plenum Cable


Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Features
Individual 4-pair horizontal cables twisted and
bound together with Kevlar cord
Patented impedance matching for zero-bit
errors
Manufactured with lead-free materials

Common Applications
4/16Mbps Token Ring (IEEE 802.5)
10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Compliances
UL Subject 444
(UL)-C(UL) Type CMP
ICEA S-90-661

11/11

102094AE

NEC 800 Type CMP


ISO/IEC 11801 Class D
TIA/EIA-568-B.2-1 Category 6 horizontal,
individual cables

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Individual cable diameter:
Jacket:

24 AWG solid bare copper


100% FEP
0.208" (5.28mm)
Non-lead, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

141

Copper Cable Solutions


Category 6 Copper Cable

TrueNet Structured Cabling

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
Impedance
(Ohms)
Freq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
550

Input
Typical
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 5
100 8

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
25 nS/100 meters @100MHz
75% @100MHz
Attenuation
(dB/100m)

Characteristic
Typical
100 5
100 3
100 3
100 3
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2
100 2

Return Loss
(dB)

Typical

Spec

Typical

Spec

1.6
3.2
4.6
5.2
6.7
7.5
8.4
9.5
13.9
18.3
23.5
27.3
31.3
34.9
38.4
41.8
50.6

2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8

20.3
35.2
41.1
40.2
41.0
41.1
42.2
39.5
40.6
36.9
38.9
35.5
36.0
35.4
32.5
33.0
28.9

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3

102094AE

NExT

11/11

Copper Connectivity Solutions Category 6

Category 6 Bundled Plenum Cable


Specifications

Freq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
400
550

Pair-To-Pair
(dB/100m)
Typical
Spec
96.4
74.3
89.9
65.3
84.6
60.8
85.3
59.3
80.5
56.2
77.5
54.8
78.8
53.3
74.3
51.9
70.4
47.4
68.5
44.3
65.9
41.4
64.1
39.8
61.4
38.3
61.1
60.7
59.1
56.1

PowerSum
(dB/100m)
Typical
Spec
89.6
72.3
83.1
63.3
78.1
58.8
77.2
57.3
72.6
54.2
70.5
52.8
72.0
51.3
67.7
49.9
63.6
45.4
61.5
42.3
58.5
39.4
56.9
37.8
55.1
36.3
53.7
53.5
51.8
47.9

Attenuation-To-NExT Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical Spec
Typical
Spec
94.8
86.7
80.0
80.1
73.8
70.0
70.4
64.8
56.5
50.2
42.4
36.8
30.1
26.2
22.3
17.3
5.5

72.3
61.5
55.4
53.3
48.7
46.3
43.8
41.2
32.0
24.5
16.3
10.8
5.5

88.0
79.9
73.5
72.0
65.9
63.0
63.6
58.2
49.7
43.2
35.0
29.6
23.8
18.8
15.1
10.0
-2.7

70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5

ELFExT
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
92.2
67.8
84.8
64.8
83.3
55.8
74.2
52.8
77.9
49.7
69.4
46.7
74.8
47.8
66.9
44.8
70.2
43.7
62.6
40.7
67.9
41.8
60.2
38.8
66.1
39.8
58.3
36.8
63.7
37.9
55.9
34.9
58.4
31.9
50.5
28.9
54.9
27.8
46.6
24.8
49.2
24.0
41.8
21.0
45.5
21.8
38.1
18.8
43.6
19.8
35.0
16.8
38.9
30.4
34.2
26.3
3.0
22.5
19.2
10.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

142

Copper Cable Solutions


Category 6 Copper Cable

Ordering Information
Bundled Diameter
(Inches)
0.39"
0.48"
0.58"

3
4
6

Weight
(lbs/kft)
84
112
168

Packaging
1000' Reel
1000' Reel
1000' Reel

Catalog Number*
TNSP-36XX02
TNSP-46XX02
TNSP-66XX02

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
ST = Standard bundled colorswhite, blue, gray, orange, yellow, green
Other reel sizes available, please contact TE Customer Service.

11/11

102094AE

TrueNet Structured Cabling

Number of Cables

www.te.com/adc

+1-952-938-8080

1-800-366-3891

143

Copper Connectivity Solutions Category 6

Category 6 Bundled Plenum Cable

Copper Cable Solutions


Category 6 Copper Cable

TrueNet Structured Cabling


102094AE

The Outback cable is a 4-pair, 23 gauge Category


6 data cable designed for outdoor use. The cable
combines excellent transmission performance and
weather resistant properties. It is intended for
outdoor installation, in buried conduit or as aerial
cable. The core contains a water blocking tape
which isolates the core from moisture.

Features
Patented AirES conductor insulation
technology enables improved signal
strength and speed with superior
electrical performance
Manufactured with lead-free materials
Moisture barrier core wrap protects pairs

Common Applications

4/16 Mb/s Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100 Mb/s TP-PMD
Broadband & Baseband Video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-Any LAN (IEEE 802.12)
52/155 Mb/s ATM (ATM Forum)
622 Mb/s ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gigabit Networking System (WGNA)
1.2 Gb/s ATM (ATM Forum)
77 Channel Broadband Video

Compliances
ETL Verified TIA/EIA-568-B.2-1 Category 6
Horizontal
ISO/IEC 11801 Category 6 Horizontal Cable
Requirements

11/11

Copper Connectivity Solutions Category 6

C6T 4 Pair Outdoor Cable

www.te.com/adc

+1-952-938-8080

1-800-366-3891

144

Copper Cable Solutions


Category 6 Copper Cable

C6T 4 Pair Outdoor Cable


CONSTRUCTION
Conductor:
Insulation:
Filler:
Core Tape:
Jacket:

23 AWG solid bare copper


Polyolefin
Polyolefin Star
Moisture barrier core wrap
Linear Low Density Polyethylene, Black 0.260" (6.6mm) nominal O.D.

THERMAL CHARACTERISTICS
Transport and Storage:
Installation:
Operation:

-20 C to 75 C
4 C to 50 C
-20 C to 75 C

Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Specifications

MECHANICAL CHARACTERISTICS
Bend Radius
During Installation:
8 X O.D.
Installed:
4 X O.D.
Pull Tension:
25 lb/f (11ON)
ELECTRICAL CHARACTERISTICS
Conductor DC Resistance @ 20C (Max):
DC Resistance Unbalance (Max):
Mutual Capacitance @ 20C (Max):
Operating Voltage (Max):
Worst Case Cable Skew:
Nominal Velocity of Propagation:

28.6 /1000 ft (9.38 /100 m)


2%
17 pF/ft (5.6nF/100 m)
300 VDC
45 ns/100 m
66%

Ordering Information
Description

Weight
LBS/KFT

Reel 10001

KG/KM
TN6TOSP-BK02

42.5

11/11

102094AE

29

Catalog Number

www.te.com/adc

+1-952-938-8080

1-800-366-3891

145

Copper Cable Solutions


Category 6 Copper Cable

102094AE

TrueNet Structured Cabling

FREq
MHZ

11/11

Copper Connectivity Solutions Category 6

C6T 4 Pair Outdoor Cable


FITTED
IMPEDANCE
Ohms

INSERTION
LOSS
dB/100m

RETURN
LOSS
dB/100m

PAIR-PAIR
NExT
dB/100m

PSNExT
dB/100m

Spec

Max

Spec

Min

Spec

Min

Spec

Min

Spec

100 +/-3

1.7

2.0

26.2

20.0

83.9

74.3

80.8

72.3

100 +/-3

3.4

3.8

33.8

22.9

80.0

65.3

76.4

63.3

100 +/-3

4.8

5.3

34.5

24.5

74.0

60.8

72.3

58.8

10

100 +/-3

5.4

6.0

37.2

25.0

68.6

59.3

67.5

57.3

16

100 +/-3

6.8

7.6

33.5

25.0

71.0

56.2

68.8

54.2

20

100 +/-3

7.6

8.5

34.8

25.0

62.7

54.8

62.2

52.8

25

100 +/-3

8.6

9.5

36.1

24.3

59.1

53.3

58.6

51.3

31.25

100 +/-3

9.6

10.7

38.8

23.6

67.2

51.9

64.7

49.9

62.5

100 +/-3

13.6

15.4

35.2

21.5

56.8

47.4

54.1

45.4

100

100 +/-3

17.3

19.8

35.0

20.1

53.7

44.3

52.1

42.3

155

100 +/-3

21.7

25.2

32.8

18.8

53.6

41.4

51.9

39.4

200

100 +/-3

24.8

29.0

32.9

18.0

47.3

39.8

45.7

37.8

32.8

31.3

17.3

49.1

38.3

47.2

36.3

250

100 +/-3

27.8

300

100 +/-3

30.6

31.3

49.4

46.5

350

100 +/-3

33.1

30.0

49.1

46.7

400

100 +/-3

35.5

26.6

41.3

40.6

550

100 +/-3

42.1

22.3

42.1

40.4

FREq
MHZ

PAIR-PAIR
ACR
dB/100m

PSACR
dB/100m

PAIR-PAIR
ELFExT
dB/100m

PSELFExT
dB/100m

LCL
dB/100m

Min

Spec

Min

Spec

Min

Spec

Min

Spec

Min

82.3

72.3

79.2

70.3

79.4

67.8

75.1

64.8

40.0

76.6

61.5

73.1

59.5

67.7

55.8

63.3

52.8

40.0

69.4

55.4

67.5

53.4

61.6

49.7

57.3

46.7

40.0

10

63.4

53.3

62.2

51.3

59.4

47.8

55.2

44.8

40.0

16

64.2

48.7

62.0

46.7

54.8

43.7

51.3

40.7

38.0

20

55.3

46.3

54.7

44.3

52.5

41.8

49.6

38.8

37.0

25

50.8

43.8

50.1

41.8

49.6

39.8

47.4

36.8

36.0

31.25

57.8

41.2

55.4

39.2

47.6

37.9

45.6

34.9

35.1

62.5

43.4

32.0

40.8

30.0

42.4

31.9

39.7

28.9

32.0

100

36.9

24.5

35.3

22.5

38.3

27.8

35.5

24.8

30.0

155

32.1

16.3

30.4

14.3

37.6

24.0

34.7

21.0

28.1

200

23.0

10.8

21.0

8.8

35.1

21.8

33.3

18.8

27.0

250

21.9

5.5

20.0

3.5

27.5

19.8

26.8

16.8

26.0

300

19.8

16.8

25.3

23.9

350

16.3

14.0

27.3

25.0

400

6.2

5.5

29.4

27.6

550

1.0

23.9

23.7

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual
compliance testing is based on swept frequency measurements. The spec values are based on TIA/EIA-568-B.2-1 specification.
www.te.com/adc

+1-952-938-8080

1-800-366-3891

146

Copper Connectivity Solutions Category 6


Patch Panels

TrueNet Patch Panels

TrueNet Category 6 patch panels feature


impedance matching for maximum performance.
Designed for mounting in standard EIA 19-inch
racks or to hinged wall mount brackets, their high
density, superior reliability and numerous labeling
options make these patch panels a superior
choice for high-performance networks.

Features and Benefits


UL certified and verified
Performance exceeds TIA/EIA
Category 6 requirements

48-port Category 6 patch panel A/B

Designed to support Gigabit Ethernet


transmission speeds
Includes rear wire manager
Wire can be terminated with either
a KRONE or 110 tool
45 degree silver-plated IDCs provide secure,
reliable gas-tight connection

24-port Category 6 patch panel, paper labels A/B

Includes paper labels or silk-screened


area for station identification
Universal wiring label for easy termination of
either T568A/B

48-port Category 6 patch panel, paper labels A/B

Ordering information follows on the next page

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

147

Copper Connectivity Solutions Category 6

24-port Category 6 patch panel A/B

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions Category 6


Patch Panels

TrueNet Patch Panels

Description

Dimensions (HxWxD)

Catalog Number

24-port silk-screened, T568A/B compatible


Quantity: 1

1.75" x 19" x 1.5"


(44.45mm x 482.6mm x 38.1mm)

6653 1 677-24

48-port silk-screened, T568A/B compatible


Quantity: 1

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

6653 1 677-48

24-port patch panel with snap-in port ID tabs


and paper labels, T568A/B compatible Quantity: 1

1.75" x 19" x 1.5"


(44.45mm x 482.6mm x 38.1mm)

6653 1 679-24

48-port patch panel with snap-in port ID tabs


and paper labels, T568A/B compatible Quantity: 1

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

6653 1 679-48

1RU

1.75" x 19" x 0.25"


(44.45mm x 482.6mm x 6.35mm)

6653 2 000-01

2RU

3.5" x 19" x 0.25"


(88.9mm x 482.6mm x 6.35mm)

6653 2 000-02

Blank panels
Used to cover open rack space in 19" rack; rolled
steel construction; durable powder coated finish
Quantity: 1

102094AE

TrueNet Structured Cabling

Ordering Information

11/11

Copper Connectivity Solutions Category 6

www.te.com/adc

+1-952-938-8080

1-800-366-3891

148

Copper Connectivity Solutions Category 6


Patch Panels

Dynamic Angle Right/Left Patch Panels


The TrueNet dynamic angle right/left panel
offers superior performance and flexibility. Unlike
fixed angle right/angle left panels, TEs patented
solution combines the ability to dynamically
angle connections either right or left in a low
profile. Forty-five degree silver plated IDCs can
be punched down with either a standard 110 or
KRONE termination tool.

Features
Patented angle right/left eases stress on patch cords allowing for improved cable management
Low profile dynamic angling allows for greater flexibility and use in cabinet environments
UL 1863 certified and Category 6 performance verified
Conductors can be terminated with either a KRONE or 110 tool
45 degree silver-plated IDCs provide secure, reliable gas-tight connection
Includes adhesive paper labels for station identification
Universal wiring label for easy termination of either T568A/B
Patch panels are designed to support Gigabit Ethernet transmission speeds
Panels can be rack mounted in standard EIA 19-inch racks or wall mounted using optional 19-inch hinged
wall mount brackets
Rear wire manager included
TrueNet ID Tab Adapter Bezel included for use with TrueNet ID Tabs

Ordering Information
Dimensions (HxWxD)

Catalog Number

24-port angle right/left patch panel,


T568A/B compatible Quantity: 1

1.75" x 19" x 1.5"


(44.45mm x 482.6mm x 38.1mm)

PP24AC6T

48-port angle right/left patch panel,


T568A/B compatible Quantity: 1

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

PP48AC6T

11/11

102094AE

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

149

Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Copper Connectivity Solutions Category 6


Patch Panels

UMS/Mini Patch Panels

6-port UMS/Mini Patch Panel, Type 105

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

Category 6 UMS/Mini Patch Panels


6-port UMS/Mini patch panel,
Type 105, T568A/B
Quantity: 1
Includes 1 patch board on 1 base; mounts
on UMS mounting bracket in Type 105
position, Type 105 rod mount bracket, Type
105 back mount frame

1.73" x 4.77" x 2.08"

6653 1 608-00

102094AE

TrueNet Structured Cabling

Combine UMS/Mini Patch Panels with Ultim8


blocks for complete patching flexibility.

11/11

Copper Connectivity Solutions Category 6

www.te.com/adc

+1-952-938-8080

1-800-366-3891

150

Copper Connectivity Solutions Category 6


Patch Panels

Patch Plus 24-port, six 4-port increments (front)

48-port high density Plug 'n' Play patch panel

24-port high density Plug 'n' Play patch panel

12-port mini
patch panel

Ordering information follows on the next page

11/11

102094AE

TrueNet Structured Cabling

Part of TEs high performance line of modular products, these blank patch panels accept all the modular
jacks and connectors available for TEs station outlets. The patch panels are designed to mount in
standard EIA 19-inch (482.6mm) racks.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

151

Copper Connectivity Solutions Category 6

Plug n Play Patch Panels

Copper Connectivity Solutions Category 6


Patch Panels

Ordering Information
Dimensions (HxWxD)

24-port Patch Plus panel


Quantity: 1
Attaches to wall mount brackets or standard
TIA/EIA racks. Includes wire management
on front and back; compatible with both
KM8 and K610 jacks. Includes station,
workstation and panel identification
labeling capabilities

Catalog Number

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

6653 2 760-24

10" x 2.75" x 1.88"


(254mm x 69.85mm x 47.8mm)

6653 2 705-12

High-density Plug n Play patch panel


Quantity: 1
Includes rear cable management. Front of
panel is silk-screened with port numbers
and label area. Adhesive labels for laser
printing also available (contact TE
Technical Assistance Center)
12-port mini patch panel
Quantity: 1
Blank mini patch panels accept all modular
jacks and connectors available for TE's
staton outlets. Includes (1) 89D bracket
Label sheets for 4 port increment panels
Quantity: 1 sheet
Contains labels for 4-port Fascia, 4-port
Patch Plus, Plug 'n' Play Patch Plus

6631 3 046-08

24-port panel, 4-port increments

1.75" x 19" x 6"


(44.45mm x 482.6mm x 152.4mm)

PP24PNPT

48-port panel, 4-port increments

3.5" x 19" x 6"


(88.9mm x 482.6mm x 152.4mm)

PP48PNPT

102094AE

TrueNet Structured Cabling

Description

11/11

Copper Connectivity Solutions Category 6

Plug n Play Patch Panels

www.te.com/adc

+1-952-938-8080

1-800-366-3891

152

Copper Connectivity Solutions Category 6


Termination Blocks

Ultim8 Termination Blocks


Features
Performance exceeds TIA/EIA Category 6
Designed to support Gigabit Ethernet
transmission speeds
A test port provides look-both-ways
testing capability without the removal
of any wires; also allows simple circuit
monitoring through use of a test cord

Ultim8 block

Provide unique patch-by-exception


functionality

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

Ultim8 block Quantity per pack: 10

8-pair; color-coding for station pairs printed on


face of block. Includes wire guides and jumper
rings. Three mounting options: snap onto universal
mounting bracket in Type 105 position; a Type 105
mounting bracket; Type 105 rod mount bracket

Adjustable
Mounting
Bracket
(in Type 105
position)

0.88" x 4.88" x 1.63"


(22.5mm x 124mm x 41.4mm)

6468 5 060-06

Horizontal
Wire Managers

Type 105
Label Holder
8-Pair Block

11/11

102094AE

TrueNet Structured Cabling

UL certified

Type 105
Label Strip

Tech Tip
Patch-by-exception improves performance and aesthetics. The advantages of HighBand 25 and Ultim8
blocks provide a cross-connection system with greater density, front side termination and fewer patch cords.
To learn more about patch-by-exception, contact TE Technical Support.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

153

Copper Connectivity Solutions Category 6

Copper Connectivity Solutions Category 6


Termination Blocks

Ultim8 Field Assembly Kits

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 6

96-pair Ultim8 kit with UMS

160-pair Ultim8 kit

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

Ultim8 field assembly kit Quantity: 1

96-pair (24-port)
Supports field termination of (24) 4-pair cables.
Includes (12) Ultim8 blocks, (2) horizontal wire
managers, (1) black or gray universal mounting
bracket and (1) Type 105 label holder with label
and protective cover

14.75" x 8.25" x 5.25"


(374.7mm x 209.6mm x 33.4mm)

96-pair (24-port) kit; including black universal


mounting kit

6636 1 596-46

96-pair (24-port) kit; including gray universal


mounting kit

6636 1 596-06

160-pair
Supports field termination of (40) 4-pair
cables. Includes (20) Ultim8 blocks, (1) Type 105
label holder, (1) 21-position Type 105 back mount
frame, protective rubber grommets for rear cable
entry holes on back mount frame

18.44" x 4.25" x 3.81"


(468.3mm x 107.9mm x 96.8mm)

6636 1 510-06

168-pair
Supports field termination of (42) 4-pair cables.
Includes (21) Ultim8 blocks, (1) 21-position
Type 105 back mount frame, protective rubber
grommets for rear cable entry holes on back
mount frame. No label holder

18.44" x 4.25" x 3.81"


(468.3mm x 107.9mm x 96.8mm)

6636 1 518-06

www.te.com/adc

+1-952-938-8080

1-800-366-3891

154

Copper Connectivity Solutions Category 6


Termination Blocks

HighBand 25 Termination Blocks

11/11

102094AE

Complete 300-pair HighBand


25 system includes back mount
frame and HighBand 25 blocks
with rear cable managers, patch
cords, cable management rings
and covers (single on left side,
dual on right side) and a cable
trough added below

HighBand 25
back mount frame

HighBand 25 label holder (shown mounted on block)


HighBand 25 block with rear cable manager

Features and Benefits


UL certified
25-pair blocks for voice and data applications (first 24 pair for data)
Performance exceeds TIA/EIA Category 6 requirements
A test port provides look-both-ways testing capability without the removal of any wires;
also allows simple circuit monitoring through use of a test cord
Features disconnect contacts providing unique patch-by-exception functionality
and improved administration
Available as individual components or in complete systems, consisting of unique wire termination
blocks, cable managers, patch cords, mounting frames, label holders and covers

Ordering information follows on the next page

Tech Tip
When installing HighBand 25 blocks, it is easier to begin wire termination at the bottom and work up the
mounting hardware.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

155

Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Copper Connectivity Solutions Category 6


Termination Blocks

Ordering Information
Dimensions (HxWxD)

Catalog Number

300-pair basic system


Consists of (1) back mount frame, (12) 25-pair
HighBand 25 blocks and (12) label holders. Patch cords,
optional cable troughs, cable management rings, covers
ordered separately

20.75" x 7.88" x 8.5"


(528mm x 200mm x 215.9mm)

6450 1 101-00

900-pair basic system


Consists of (3) back mount frames, (36) 25-pair
HighBand 25 blocks, (36) label holders. Patch cords,
optional cable troughs, cable management rings, covers
ordered separately

62.25" x 7.88" x 8.5"


(1581.2mm x 200mm x 215.9mm)

6450 1 102-00

300-pair cable management kit


Includes (2) dual cable management rings
and (1) dual cover

20.6" x 8.62" x 8.6"


(523mm x 219mm x 218.5mm)

6450 1 103-00

900-pair cable management kit


Includes (6) dual cable management rings
and (3) dual covers

61.8" x 8.62" x 8.6"


(1569.7mm x 219mm x 218.5mm)

6450 1 104-00

HighBand 25 block with rear cable manager


Color-coded; terminates (6) 4-pair Category 6 cables.
Rear cable manager simplifies installation; incoming cables
routed through slots and held securely by built-in clips
Quantity: 12

1.7" x 8.5" x 4.5"


(43.2mm x 215.9mm x 114.3mm)

6468 5 600-00

HighBand 25 25-pair voice module


with rear cable manager Quantity: 12

1.7" x 8.5" x 4.5"


(43.2mm x 215.9mm x 114.3mm)

6468 5 300-00

HighBand 25 25-pair block systems

Ordering information continues on the next page

102094AE

TrueNet Structured Cabling

Description

11/11

Copper Connectivity Solutions Category 6

HighBand 25 Termination Blocks

www.te.com/adc

+1-952-938-8080

1-800-366-3891

156

Copper Connectivity Solutions Category 6


Termination Blocks

Ordering Information

TrueNet Structured Cabling

Description

Dimensions (HxWxD)

Catalog Number

HighBand 25 label holder


Clips into position in three locations, providing secure fit
without disrupting patching Quantity: 12

0.47" x 8.5" x 0.3"


(11.9mm x 215.9mm x 7.6mm)

6462 2 408-00

HighBand 25 back mount frame


High-grade stainless steel; extra deep frame supports
strict Category 6 bend radius requirements; Velcro tie
points allow neat installation and ease of cable routing
Quantity: 1

20.8" x 7.87" x 4.38"


(529mm x 200mm x 111.3mm)

6450 2 155-00

HighBand 25 cable trough


Mounts on top or bottom of each back mount frame;
provides superior patch cord management
Quantity: 1

5.9" x 7.87" x 8.6"


(150mm x 200mm x 218.5mm)

6450 2 157-00

Single: Use when space is limited or additional cable


manager required

2.5" x 8.5" x 8.25"


(63.5mm x 140.3mm x 209.6mm)

6450 2 158-01

Dual: Position between 2 frames

2.5" x 5.5" x 8.25"


(63.5mm x 215.9mm x 209.6mm)

6450 2 158-02

HighBand 25 cable management rings


Quantity: 2

HighBand 25 19" rack mount frame kits


Quantity: 1, Includes Blocks
2RU100-pair
3RU200-pair
4RU300-pair

6450 1 176-00
6450 1 177-00
6450 1 178-00

2RU100-pair
3RU200-pair
4RU300-pair

6450 2 176-00
6450 2 177-00
6450 2 178-00

11/11

102094AE

HighBand 25 19" rack mount frames only

www.te.com/adc

+1-952-938-8080

1-800-366-3891

157

Copper Connectivity Solutions Category 6

HighBand 25 Termination Blocks

Copper Connectivity Solutions Category 6


Modular Jacks

KM8 Modular Jacks

TrueNet Structured Cabling

KM8 modular jacks are an integral part of the


TrueNet channel solution. Tuned together with
other TrueNet Category 6 components and cable,
KM8 jacks help deliver zero-bit-error network
performance.
A KM8 modular jack with cable management
system ensures reliable field termination. The
cable manager holds cable pairs in place up to
the termination point, preventing cable untwist
and buckle, guaranteeing dependable and
repeatable performance. All four pairs terminate
at once without a tool for the tool-less jack,
reducing termination time and effort.

KM8 modular jack

These modular jacks can be used in TEs modular


patch panels.

Features
TrueNet impedance matched jacks
guarantee maximum throughput
Meet TIA/EIA Category 6 requirements
45-degree silver-plated IDCs provide secure,
reliable gas-tight connections
Compatible with any TrueNet modular
faceplate, modular furniture faceplate,
surface box and modular patch panel
Accepts either a KRONE or 110 tool for
wire termination for punchdown jack

102094AE

Universal A/B wiring label

11/11

Copper Connectivity Solutions Category 6

Ordering Information
Description

Catalog Number

KM8 RJ45 modular punchdown jack Quantity: 1

6830 1 830-XX

*Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black
05 = Red
06 = Blue

www.te.com/adc

07
08
09
10
22

=
=
=
=
=

Green
Yellow
Purple
Orange
Electrical ivory

+1-952-938-8080

1-800-366-3891

158

Copper Connectivity Solutions Category 6


Patch Cords
Patch Cords

11/11

102094AE

Impedance matched for use in TrueNet structured


cabling systems, these patch cords exceed Category
6 requirements. The plug is designed with built-in
strain relievers that prevent the cable from moving
at the termination point when the cable is flexed.
The strain relievers also maintain proper bend radius.
Both these innovations are designed to ensure
maximum throughput in TrueNet installations.

Category 6 patch cord

Features
UL certified and verified
Meets or exceeds TIA/EIA Category 6 component specification
Copper conductors in the cable pairs are stranded for superior flexibility and compacted to a near-round
shape to enhance impedance values
Durable design to be in operation beyond 20-year product warranty
Impedance matched patch cord for maximum throughput
Flexible strain relief boot maintains proper bend radius to ensure peak performance

Ordering Information
Description
RJ45 plug to RJ45 plug, T568B Quantity: 1
RJ45 plug (T568B)

RJ45 plug (T568B)

RJ45 plug to RJ45 plug, T568A Quantity: 1


RJ45 plug (T568A)

RJ45 plug (T568A)

RJ45 plug to RJ45 plug, crossover wired, Quantity: 1


RJ45 plug (T568B)

RJ45 plug (T568A)

Cable Color

Catalog Number*

Blue
Green
Gray
Red
White
Yellow
Blue
Green
Gray
Red
White
Yellow
Blue
Green
Gray
Red
White
Yellow

6645-2-781-XX
6645-2-784-XX
6645-2-787-XX
6645-2-782-XX
6645-2-780-XX
6645-2-783-XX
6645-2-771-XX
6645-2-774-XX
6645-2-777-XX
6645-2-772-XX
6645-2-770-XX
6645-2-773-XX
6645-2-791-XX
6645-2-794-XX
6645-2-797-XX
6645-2-792-XX
6645-2-790-XX
6645-2-793-XX

*Replace XX with:
04 = 4'
07 = 7'
10 = 10'
15 = 15'
25 = 25'
50 = 50'
Contact TE for additional cable colors and lengths.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

159

Copper Connectivity Solutions Category 6

TrueNet Structured Cabling

Copper Connectivity Solutions Category 6


Patch Cords

Patch Cords for Ultim8 Blocks

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 6

These patch cords allow direct patching


capability between Ultim8 blocks or patching
from an Ultim8 block to an active device or an
RJ45 patch panel.
Ultim8 to RJ45 patch cord

Ultim8 to Ultim8 patch cord

Ordering Information
Description

Cable Color

Catalog Number*

Ultim8 plug to Ultim8 plug,


wired straight through; wired top (cable) side only
Quantity: 1

White

TP6TH-WTXX

Blue

TP6TH-BLXX

Red

TP6TH-RDXX

Pair No.

Green

TP6TH-GNXX

Yellow

TP6TH-YLXX

Gray

TP6TH-GYXX

White

TP6TB0WTXX

Blue

TP6TB0BLXX

Red

TP6TB0RDXX

Green

TP6TB0GNXX

Yellow

TP6TB0YLXX

Gray

TP6TB0GYXX

White

TP6TB-WTXX

Blue

TP6TB-BLXX

Red

TP6TB-RDXX

Green

TP6TB-GNXX

Yellow

TP6TB-YLXX

Gray

TP6TB-GYXX

Pair 4
Pair 3
Pair 2
Pair 1

R
T
R
T
R
T
R
T

Ultim8 plug to RJ45 plug, T568A Quantity: 1


RJ45 Plug
Pin #
8
7
2
1
6
3
4
5

Pair No.
Pair 4
Pair 3
Pair 2
Pair 1

R
T
R
T
R
T
R
T

Ultim8 plug to RJ45 plug, T568B Quantity: 1


RJ45 Plug
Pin #
8
7
6
3
2
1
4
5

Pair No.
Pair 4
Pair 3
Pair 2
Pair 1

R
T
R
T
R
T
R
T

*Replace XX with:
04 = 4'
07 = 7'
10 = 10'
15 = 15'
25 = 25'
50 = 50'
Contact TE for additional cable colors and lengths.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

160

Copper Connectivity Solutions Category 6


Patch Cords

Copper Connectivity Solutions Category 6

Ultim8 2-pair patch cord

Ordering Information
Description

Catalog Number*

Ultim8 plug to Ultim8 plug,


1-pair, wired top (cable) side only, white cable
Quantity: 1

6648 2 000-XX

Pair No.
Pair 1

R
T

6648 2 005-XX

Ultim8 plug to Ultim8 plug,


2-pair, wired top (cable) side only, white cable
Quantity: 1

Pair 2
Pair 1

R
T
R
T

KRONE

Pair No.

*Replace XX with:
04 = 4'
07 = 7'
10 = 10'
15 = 15'
25 = 25'
50 = 50'

11/11

102094AE

These patch cords provide direct patching capability


using standard straight-through wiring. Ultim8 block
plugs are keyed for proper insertion and have
a latching mechanism to keep them secure. These
patch cords are recommended for 10Base-T/Token
Ring or voice installations using Ultim8 blocks.

KRONE

TrueNet Structured Cabling

Ultim8 1- and 2-Pair Patch Cords

www.te.com/adc

+1-952-938-8080

1-800-366-3891

161

Copper Connectivity Solutions Category 6


Patch Cords

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 6

HighBand 25 Patch Cords

HighBand 25 patch cord, 4-pair and 1-pair

Features
Meets or exceeds TIA/EIA Category 6 component specifications
Available in 4-pair to 4-pair or 4-pair to RJ45 configurations
Directed to rear or front of block and fed into vertical cable managers for clean,
professional appearance
Can be labeled to identify specific services
Innovative anti-snag boot simplifies removal
Single pair patch cords available for voice applications or for single pair testing

Ordering Information
Description

Catalog Number*

HighBand 25 patch cords Quantity: 1


4-pair to 4-pair rear

6451 2 701-XX

4-pair to RJ45 568A rear

6451 2 700-XX

1-pair to 1-pair front

6451 2 702-XX

4-pair to 4-pair front

6451 2 703-XX

4-pair to RJ45 568A front

6451 2 704-XX

4-pair to RJ45 568B front

6451 2 706-XX

*Replace XX with:
10 = 4'
20 = 7'
30 = 10'
40 = 15'

www.te.com/adc

+1-952-938-8080

1-800-366-3891

162

Copper Connectivity Solutions Category 6


Patch Cords

Copper Connectivity Solutions Category 6

Impedance matched for use in TrueNet


structured cabling systems; these specialty patch
cords exceed all performance requirements
for Category 6. The plug is designed with
integrated strain relievers that prevent the cable
from moving at the termination point when the
cable is flexed, safeguarding circuit integrity and
guaranteeing maximum performance. The strain
relievers also ensure that proper bend radii are
maintained throughout the network. These cords
are available in plenum or riser versions to meet
all requirements within the LAN and Data Center
environment. The specialty cable assemblies
are available in plug to plug or jack to plug
configuration for ease of installation in a data
center or a zone cabling application.

Features
Exceeds TIA/EIA Category 6 requirements
Cable assemblies are available in riser or plenum solid horizontal cable versions
Durable design to be in operation beyond 20-year product warranty
Impedance matched patch cord for maximum throughput
Flexible strain relief boot maintains proper bend radius to ensure peak performance
Plug to jack cable assemblies utilizes TEs KM8 Laser Tuned jack and LSA-PLUS 45 degree
angle IDC design.
Up to 32 percent smaller outer diameter than other patch cords
UL 1863 listed and Category 6 performance verified

11/11

102094AE

TrueNet Structured Cabling

Category 6 Specialty Patch Cords

www.te.com/adc

+1-952-938-8080

1-800-366-3891

163

Copper Connectivity Solutions Category 6


Patch Cords

TrueNet Structured Cabling

Specifications
Operating Temperature Range:
RJ45 Plug Interface According to:
Transmission Performance and Reliability:
Number of Plug Insertion Cycles:
Conductor:
Nominal Outer Diameter:
Safety Rating:
Flammability Rating:

-10 to 60 C (14 to 140 F)


IEC 60603-7
TIA/EIA 568-B.2-1 Category 6
ISO 11801 Class E standard
750 (IEC/EN 60603-7)
23 AWG
5.28mm (.208") Plenum and 5.5mm (.215") Riser
UL 1863
UL 94 V-0

Note: See TrueNet Category 6 Plenum and Riser data sheets for additional detail for cable specifications.

Ordering Information
Description

Catalog Number

Patch Cords R45 Plug to RJ45 Plug


C6 UTP RJ45 plug to RJ45 568A plug Riser Patch Cord

TP6TZR0XXYY

C6 UTP RJ45 plug to RJ45 568B plug Riser Patch Cord

TP6TZR-XXYY

C6 UTP RJ45 plug to RJ45 568A plug Plenum Patch Cord

TP6TZP0XXYY

C6 UTP RJ45 plug to RJ45 568B plug Plenum Patch Cord

TP6TZP-XXYY

Sub XX for color: BL=Blue, BK=Black, GY=Gray, RD=Red, GN=Green, YL=Yellow, WT=White
Sub YY for length: 04= 4 feet, 07= 7 feet, 10=10 feet, 15=15 Feet, 25=25 feet, 50=50 feet
Call TE for additional colors and lengths.

Ordering Information
Description

Catalog Number

102094AE

Sub XX for color: BL=Blue, BK=Black, GY=Gray, GN=Green, IV=Ivory, RD=Red, YL=Yellow, WT=White, OR=Orange, VT= Violet
Sub YY for length: 07= 7 feet, 15=15 Feet, 25=25 feet, 30= 30 feet, 35= 35 feet 50=50 feet

Patch Cords R45 Plug to RJ45 Jack

Call TE for additional lengths.

C6 UTP RJ45 plug to RJ45 jack 568A Riser Patch

TP6TZJ0XXYY

C6 UTP RJ45 plug to RJ45 jack 568B Riser Patch

TP6TZJ-XXYY

C6 UTP RJ45 plug to RJ45 jack 568A Plenum Patch Cord

TP6TZJP0XXYY

C6 UTP RJ45 plug to RJ45 jack 568B Plenum Patch Cord

TP6TZJP-XXYY

Plenum cable assemblies use blue cable and riser cable assemblies use white cable. Only the KM8 jack color will change.

11/11

Copper Connectivity Solutions Category 6

Category 6 Specialty Patch Cords

www.te.com/adc

+1-952-938-8080

1-800-366-3891

164

Category 5e Copper Cable ............................................ 168


Patch Panels .................................................................. 180
Modular Jacks ................................................................ 184
Patch Cords ................................................................... 185

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

165

Copper Connectivity Solutions Category 5e

Introduction ................................................................... 166

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions


Category 5e

Copper Connectivity Solutions Category 5e


Introduction

TrueNet Structured Cabling

The proof of the TrueNet performance is in the test results. The graphs below depict the rise time of both
an impedance mismatched and matched system. The mismatched channel falls out of the IEEE
specification; the TrueNet system keeps rise time within the IEEE specifications, preserving signal integrity.
TrueNet Category 5e solutions deliver:
A complete end-to-end channel
Extra bandwidth, better attenuation
Zero bit errors
ANSI/EIA/TIA-568-B Category 5e compliance
ISO/IEC 11801, Class D compliance
TrueNet Signal Rise Time

Mismatched Signal Rise Time

The mismatched channels corrupted signal causes


rise time to fall out of IEEE specifications.

The TrueNet channel keeps rise time within


specifications, preserving signal integrity.

102094AE

TrueNet patch panels are manufactured in 24-port (1RU) or 48-port (2RU) configurations to provide
high-density modular patching solutions for all high-density applications where space is limited.
The LSA-PLUS IDC technology provides a secure, reliable and gas-tight connection and allows for
the wire to be terminated with either a KRONE insertion tool or a 110 termination tool.

11/11

Copper Connectivity Solutions Category 5e

Exceeding IEEE Category 5e standards, TEs TrueNet Category 5e patch panels, patch cords, modular
jacks, and cable are impedance matched to deliver extra bandwidth and better attenuation with
zero bit errors.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

166

Copper Connectivity Solutions Category 5e


Introduction

TrueNet Category 5e
RJ45 Modular Solution
TrueNet Cable

Plug n Play K610


Patch Panel Jacks
with K610
Jacks

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

Hub Switch

TrueNet
Patch Cord

TrueNet Patch Cord


TrueNet Cable

Hub Switch

TrueNet
Patch Panel

K610
Jacks

TrueNet
Patch Cord

TrueNet Patch Cord

TrueNet Category 5e
IDC FT Block Solution
TrueNet Cable

Feed-Thru
(FT) Block

K610
Jacks

TrueNet
Patch Cord

TrueNet Patch Cord

11/11

102094AE

Hub Switch

www.te.com/adc

+1-952-938-8080

1-800-366-3891

167

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable
Category 5e Plenum Cable

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 5e

TrueNet Category 5e Plenum cable


is protected by US Patents 6153826

TrueNet Category 5e Plenum cable


is also available in a side-by-side configuration

Common Applications

Compliances

4/16Mbps Token Ring (IEEE 802.5)

UL Subject 444

10Base-T (IEEE 802.3)

(UL)-C(UL) Type MPP/CMP

100Mbps TP-PMD

ICEA S-90-661

Broadband and baseband video

NEC 800 Type CMP

100Base-T (Fast Ethernet)

ISO/IEC 11801 Class D

100Base-T4 (Fast Ethernet)

ETL verified TIA/EIA-568-B.2-1 Category 5e


horizontal cable requirements

100Base-TX (Fast Ethernet)


100VG-AnyLAN (IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Pairing:
Color-coding:
Jacket:

24 AWG solid bare copper


100% FEP
Short, staggered pair lays
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

168

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable
Category 5e Plenum Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
FITTED
FREq IMPEDANCE
(MHz)
(Ohms)
SPEC
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
FREq
(MHz)
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

5
3
3
3
3
3
3
3
3
3
3
3
3
3
3

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
22 nS/100 meters @100MHz
76%

INSERTION LOSS
(dB/100m)

RETURN LOSS
(dB/100m)

Max

TIA Spec

Min

1.9
3.7
5.3
6.0
7.6
8.6
9.6
10.8
15.5
19.8
25.1
28.9
32.5
35.9
39.3

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

Pair-Pair ACR
(dB/100m)

33.1
30.1
32.7
31.4
37.0
37.5
35.1
34.4
33.2
29.8
29.3
22.9
25.0
22.5
22.4

PSACR
(dB/100m)

Min

TIA Spec

Min

TIA Spec

78.0
68.6
59.1
57.8
53.8
51.2
49.0
47.9
36.9
29.4
26.2
18.7
10.1
7.7
1.8

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

76.3
64.2
58.1
56.4
52.0
49.4
47.3
44.1
34.8
27.4
22.8
16.6
8.6
5.2
0.3

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

Pair-Pair NEXT
(dB/100m)

TIA Spec

Min

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

79.8
72.4
64.4
63.7
61.4
59.7
58.7
58.7
52.4
49.3
51.3
47.5
42.6
43.6
41.1

Pair-Pair ELFEXT
(dB/100m)
Min

TIA Spec

70.2
58.9
52.8
51.1
47.4
45.0
43.0
41.4
35.2
32.0
28.7
27.4
25.8
24.4
22.8

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

PSNEXT
(dB/100m)

TIA Spec
65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

Min
78.1
67.9
63.5
62.4
59.7
58.0
56.9
54.9
50.3
47.2
47.9
45.5
41.1
41.1
39.6

TIA Spec
62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

PSELFEXT
(dB/100m)
Min
70.0
58.7
52.5
50.8
47.1
44.9
42.6
41.1
35.2
31.7
28.6
27.3
25.4
23.8
22.1

TIA Spec
60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only.
Actual compliance testing is based on swept frequency measurements. The spec values are also based on the
TIA/EIA-568-B.2 specification.

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

169

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

Specifications

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable
Category 5e Plenum Cable
Ordering Information
Catalog Number*

4-pair cable
Nominal OD: 0.180" (4.57mm)
Maximum Average OD: 0.185" (4.7mm)
Reel packaging

21

TN5ESP-XXYY

Reel in a box1000'

23

TN5ESP-XXRB

Reelex1000'

21

TN5ESP-XXII

4-pair, side-by-side cable


Nominal OD: 0.19" x 0.40" (4.83mm x 10.16mm)

50

TN5ESPX2-XXYY

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
*To designate reel length, replace YY with:
02 = 1000'
04 = 2000'

102094AE

TrueNet Structured Cabling

Weight (Lbs/kft)

11/11

Copper Connectivity Solutions Category 5e

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

170

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable
Category 5e Riser Cable

11/11

102094AE

TrueNet Category 5e riser cable is also


available in a side-by-side configuration

TrueNet Category 5e riser cable


is protected by US Patent 6153826

Common Applications

Compliances

4/16Mbps Token Ring (IEEE 802.5)

UL Subject 444

10Base-T (IEEE 802.3)

(UL)-C(UL) Type CMR/CMG

100Mbps TP-PMD

ICEA S-90-661

Broadband and baseband video

NEC 800 Type CMR

100Base-T (Fast Ethernet)

ISO/IEC 11801 Category 5e

100Base-T4 (Fast Ethernet)

ETL verified TIA/EIA-568-B.2-1 Category 5e


horizontal cable requirements

100Base-TX (Fast Ethernet)


100VG-AnyLAN ( IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Jacket:

24 AWG solid bare copper


Polyolefin
Short, staggered pair lays
See Technical Reference Section, UTP color-code table
Lead-free, flame retardant PVC

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

171

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e Riser Cable CMR

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 5e

Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

FREq
(MHz)

FITTED
IMPEDANCE
(Ohms)
SPEC

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

5
3
3
3
3
3
3
3
3
3
3
3
3
3
3

28.6/1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
22 nS/100 meters @100MHz
70%

INSERTION LOSS
(dB/100m)

RETURN LOSS
(dB/100m)

Max

Min

TIA Spec

Min

TIA Spec

Min

33.7
38.9
35.6
36.4
36.9
35.1
36.4
33.3
31.6
32.8
23.7
24.8
23.3
21.9
21.7

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

80.2
68.7
63.0
61.8
59.0
60.0
55.7
53.7
51.6
46.4
44.6
46.6
42.1
42.0
34.5

65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

78.0
66.6
61.7
59.2
55.8
58.3
54.2
52.3
50.4
44.1
43.1
43.3
40.8
39.1
32.9

TIA Spec

1.9
3.8
5.4
6.1
7.7
8.7
9.8
10.9
15.6
20.0
25.1
28.8
32.2
35.5
38.6

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

FREq
(MHz)

Pair-Pair ACR
(dB/100m)

PSACR
(dB/100m)

Min

TIA Spec

Min

TIA Spec

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

78.3
64.9
57.5
55.7
51.3
51.3
46.0
42.7
36.0
26.4
19.4
17.8
9.8
6.6

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

76.1
62.8
56.3
53.1
48.1
49.6
44.4
41.4
34.8
24.1
18.0
14.5
8.6
3.7

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

Pair-Pair NEXT
(dB/100m)

Pair-Pair ELFEXT
(dB/100m)
Min

74.6
63.5
56.0
54.1
51.2
49.3
47.9
45.2
39.4
36.6
30.4
28.0
24.9
24.7
22.8

PSNEXT
(dB/100m)
TIA Spec

62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

PSELFEXT
(dB/100m)

TIA Spec

Min

TIA Spec

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

73.8
62.5
55.4
53.8
50.7
48.7
47.2
44.8
38.8
35.7
29.5
28.0
23.7
24.8
21.6

60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2 specifications.

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

172

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e Riser Cable CMR


Ordering Information
Weight (Lbs/kft)

Catalog Number*

Reel packaging

20

TN5ESR-XXYY

Reelex1000'

20

TN5ESR-XXII

Reel in a box1000'

22

TN5ESR-XXRB

4-pair, side-by-side cable


Nominal OD: 0.19" x 0.40" (4.83mm x 10.16mm)

52

TN5ESRX2-XXYY

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
*To designate reel length, replace YY with:
02 = 1000'
04 = 2000'

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

173

Copper Connectivity Solutions Category 5e

4-pair cable
Nominal OD: 0.185" (4.7mm)

102094AE

TrueNet Structured Cabling

Description

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e Bundled Riser Cable

TrueNet Structured Cabling


102094AE

4/16Mbps Token Ring (IEEE 802.5)


10Base-T (IEEE 802.3)
100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN ( IEEE 802.12)
TrueNet Category 5e bundled cable
is protected by US Patent 6153826

52/155Mbps ATM (ATM Forum)


622Mbps ATM (ATM Forum)
1000Base-T (Gigabit Ethernet)
1Gbps Networking System (WGNA)

Compliances
UL Subject 444
(UL)-C(UL) Type CMR/CMG
ICEA S-90-661
NEC 800 Type CMR
TIA/EIA-568-B.2 Category 5e horizontal,
individual cables

Specifications
CONSTRUCTION
Features AirES technology
Conductors:
Insulation:
Jacket:

24 AWG solid bare copper


100% Polyolefin
Lead-free, flame retardant PVC

Performance information follows on the next page

11/11

Copper Connectivity Solutions Category 5e

Common Applications

www.te.com/adc

+1-952-938-8080

1-800-366-3891

174

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e Bundled Riser Cable

11/11

102094AE

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:
Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350
Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

Impedance
(Ohms)

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
45 nS/100 meters @100MHz
70% @100MHz

Attenuation
(dB)

Return Loss
(dB)

Characteristic
Typical

Input
Typical

Typical

Spec

Typical

Spec

100 10
100 8
100 6
100 6
100 5
100 5
100 4
100 4
100 3
100 3
100 3
100 3

100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10

1.8
3.7
5.2
5.8
7.5
8.4
9.4
10.5
15.1
19.5
24.4
27.8
31.5
34.8
37.6

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

44.5
46.2
45.1
41.6
44.5
44.3
43.4
43.5
41.4
42.1
43.7
39.6
38.6
40.0
37.5

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

NEXT
Pair-To-Pair
(dB/100m)
Typical
Spec
87.1
77.1
70.6
70.8
67.8
66.9
64.0
63.6
58.6
55.5
52.1
49.9
48.5
48.2
46.4

65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

PowerSum
(dB/100m)
Typical
Spec
80.6
70.1
63.9
63.9
60.6
59.9
57.5
56.1
51.9
49.5
45.4
43.6
42.1
41.4
39.9

Bundled
PowerSum
Spec

62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

65.0
59.3
54.8
53.3
50.2
48.8
47.3
45.9
41.4
38.3

Attenuation-To-NEXT-Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
85.3
73.4
65.4
64.7
60.4
58.5
54.6
53.1
43.6
36.0
27.7
22.2
17.1
13.4
8.8

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

78.8
66.3
58.6
58.1
53.1
51.5
48.1
45.5
36.8
29.9
21.0
15.8
10.5
6.5
2.3

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

ELFEXT
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
85.0
75.2
67.4
65.4
60.8
58.6
56.3
55.0
48.9
45.2
41.2
38.2
35.0
32.4
29.6

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

77.5
66.5
59.1
57.9
53.5
51.4
49.5
48.2
42.0
38.7
34.8
31.5
28.6
26.2
22.6

60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

175

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

Specifications

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e Bundled Riser Cable


Ordering Information

3
4
6

Weight
(lbs/kft)
71
95
143

Packaging
Reel
Reel
Reel

Catalog Number*
TNSR-3EXX02
TNSR-4EXX02
TNSR-6EXX02

*To order cable sheath color, replace XX with:


BL = Blue
WT = White
GY = Gray
GN = Green
YL = Yellow
RD = Red
ST = Standard bundled colors
Other reel sizes available, please contact TE customer service.

102094AE

TrueNet Structured Cabling

Bundled Diameter
(Inches)
0.37"
0.40"
0.54"

11/11

Copper Connectivity Solutions Category 5e

Number of Cables

www.te.com/adc

+1-952-938-8080

1-800-366-3891

176

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

11/11

102094AE

The Outback cable is a 4-pair, 24 gauge, Category


5e data cable designed for outdoor use. The
cable combines excellent transmission and weather
resistant properties. It is intended for outdoor
installation, in buried conduit, or as aerial cable.
The core contains a heat and water-blocking tape,
which isolates the core from extreme temperature
and moisture.
Common Applications
4/16Mbps Token Ring (IEEE 802.5)

Category 5e The Outback Cable is protected


by US Patent 6153826

10Base-T (IEEE 802.3)


100Mbps TP-PMD
Broadband and baseband video
100Base-T (Fast Ethernet)
100Base-T4 (Fast Ethernet)
100Base-TX (Fast Ethernet)
100VG-AnyLAN ( IEEE 802.12)
52/155Mbps ATM (ATM Forum)
622Mbps ATM (ATM Forum)

Compliances

1000Base-T (Gigabit Ethernet)

TIA/EIA-568-B.2 Category 5e horizontal


cable requirements

1Gbps Networking System (WGNA)

Specifications
CONSTRUCTION
Conductors:
Insulation:
Pairing:
Color-coding:
Core tape:
Jacket:

24 AWG solid bare copper


100% Polyolefin
Short, staggered pair lays
See Technical Reference Section, UTP color-code table
Heat and moisture barrier core wrap
Linear low-density Polyethelyene, black

ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
DC resistance unbalance (maximum):
Mutual capacitance (maximum):
Operating temperature (maximum):
Operating voltage (maximum):
Worst case cable skew:
Nominal velocity of propagation:

28.6 /1000 feet (9.38/100 meters) @20C


2%
17 pF/foot (5.6nF/100 meters)
75C
300VDC
45 nS/100 meters @100MHz
69% @100MHz

Performance information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

177

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

Category 5e The Outback Outdoor Cable

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e The Outback Outdoor Cable

TrueNet Structured Cabling


102094AE

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

Freq
(MHz)

1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
300
350

Impedance
(Ohms)

Attenuation
(dB)

Return Loss
(dB)

Characteristic
Typical

Input
Typical

Typical

Spec

Typical

Spec

100 10
100 8
100 6
100 6
100 5
100 5
100 4
100 4
100 3
100 3
100 3
100 3

100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10
100 10

1.8
3.7
5.2
5.8
7.5
8.4
9.4
10.5
15.1
19.5
24.4
27.8
31.5
34.8
37.6

2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0

44.5
46.2
45.1
41.6
44.5
44.3
43.4
43.5
41.4
42.1
43.7
39.6
38.6
40.0
37.5

20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1

Attenuation-To-NEXT-Ratio
Pair-To-Pair
PowerSum
(dB/100m)
(dB/100m)
Typical
Spec
Typical
Spec
85.3
73.4
65.4
64.7
60.4
58.5
54.6
53.1
43.6
36.0
27.7
22.2
17.1
13.4
8.8

NEXT
Pair-To-Pair
(dB/100m)
Typical
Spec
87.1
77.1
70.6
70.8
67.8
66.9
64.0
63.6
58.6
55.5
52.1
49.9
48.5
48.2
46.4

65.3
56.3
51.8
50.3
47.2
45.8
44.3
42.9
38.4
35.3

63.3
52.2
46.0
43.8
39.0
36.5
33.9
31.2
21.4
13.3

78.8
66.3
58.6
58.1
53.1
51.5
48.1
45.5
36.8
29.9
21.0
15.8
10.5
6.5
2.3

60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3

ELFEXT
PowerSum
(dB/100m)
Typical
Spec
80.6
70.1
63.9
63.9
60.6
59.9
57.5
56.1
51.9
49.5
45.4
43.6
42.1
41.4
39.9

Pair-To-Pair
(dB/100m)
Typical
Spec

62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3

85.0
75.2
67.4
65.4
60.8
58.6
56.3
55.0
48.9
45.2
41.2
38.2
35.0
32.4
29.6

63.8
51.8
45.7
43.8
39.7
37.8
35.8
33.9
27.9
23.8

PowerSum
(dB/100m)
Typical
Spec
77.5
66.5
59.1
57.9
53.5
51.4
49.5
48.2
42.0
38.7
34.8
31.5
28.6
26.2
22.6

60.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8

NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are also based on the TIA/EIA-568-B.2 specification.

11/11

Copper Connectivity Solutions Category 5e

Freq
(MHz)

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

178

Copper Connectivity Solutions Category 5e


Category 5e Copper Cable

Category 5e The Outback Outdoor Cable


Ordering Information
Weight (Lbs/kft)

Catalog Number*

Reel packaging1000'

21

TN5ETOSP-BK02

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

179

Copper Connectivity Solutions Category 5e

4-pair cable
Nominal OD: 0.22" (5.59mm), black jacket

102094AE

TrueNet Structured Cabling

Description

Copper Connectivity Solutions Category 5e


Patch Panels

TrueNet Patch Panels

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Category 5e

TE TrueNet Category 5e patch panels provide


Category 5e performance in a high-density
design with concise station and port labeling.

24-port enhanced patch panel A/B

24-port enhanced patch panel, paper labels, A/B

48-port enhanced patch panel A/B

48-port enhanced patch panel, paper labels, A/B

Features
UL 1863 certified and Category 5e
performance verified

Universal wiring label for easy termination of


either T568A/B

Include rear wire manager

Patch panels are designed to support Gigabit


Ethernet transmission speeds

Wire can be terminated with either a KRONE or


110 tool
45 degree silver-plated IDCs provide secure, reliable gas-tight connection

Panels can be rack mounted in standard EIA


19-inch racks or wall mounted using optional
19-inch hinged wall mount brackets

Include paper labels or silk-screened area for


station identification

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

24-port silk-screened patch panel,


T568A/B compatible Quantity: 1

1.75" x 19" x 1.5"


(44.45mm x 482.6mm x 38.1mm)

6653 1 585-24

48-port silk-screened patch panel,


T568A/B compatible Quantity: 1

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

6653 1 585-48

24-port patch panel with snap-in port


ID tabs and paper labels,
T568A/B compatible Quantity: 1

1.75" x 19" x 1.5"


(44.45mm x 482.6mm x 38.1mm)

6653 1 587-24

48-port patch panel with snap-in port


ID tabs and paper labels,
T568A/B compatible Quantity: 1

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

6653 1 587-48

www.te.com/adc

+1-952-938-8080

1-800-366-3891

180

Copper Connectivity Solutions Category 5e


Patch Panels

Dynamic Angle Right/Left Patch Panels


The TrueNet dynamic angle right/left panel
offers superior performance and flexibility. Unlike
fixed angle right/angle left panels, TEs patented
solution combines the ability to dynamically
angle connections either right or left in a low
profile. Forty-five degree silver plated IDCs can
be punched down with either a standard 110 or
KRONE termination tool.

Features
Patented angle right/left eases stress on patch cords allowing for improved cable management
Low profile dynamic angling allows for greater flexibility and use in cabinet environments
UL 1863 certified and Category 5e performance verified
Conductors can be terminated with either a KRONE or 110 tool
45 degree silver-plated IDCs provide secure, reliable gas-tight connection
Includes adhesive paper labels for station identification
Universal wiring label for easy termination of either T568A/B
Patch panels are designed to support Gigabit Ethernet transmission speeds
Panels can be rack mounted in standard EIA 19-inch racks or wall mounted using optional 19-inch
hinged wall mount brackets
Rear Wire Manager included
TrueNet ID Tab adapter bezel included for use with TrueNet ID Tabs

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

24-port angle right/left patch panel,


T568A/B compatible Quantity: 1

1.75" x 19" x 1.5"


(44.45mm x 482.6mm x 38.1mm)

PP24AC5ET

48-port angle right/left patch panel,


T568A/B compatible Quantity: 1

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

PP48AC5ET

11/11

102094AE

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

www.te.com/adc

+1-952-938-8080

1-800-366-3891

181

Copper Connectivity Solutions Category 5e


Patch Panels

Plug n Play Patch Panels

TrueNet Structured Cabling

12-port mini
patch panel

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

24-port Patch Plus panel


Quantity: 1
Attaches to wall mount brackets or standard
TIA/EIA racks. Includes wire management
on front and back; compatible with both
KM8 and K610 jacks. Includes station,
workstation and panel identification labeling
capabilities

3.5" x 19" x 1.5"


(88.9mm x 482.6mm x 38.1mm)

6653 2 760-24

12-port mini patch panel


Quantity: 1
Blank mini patch panels accept all modular
jacks and connectors available for TEs
station outlets. Includes (1) 89D bracket

10" x 2.75" x 1.88"


(254mm x 69.85mm x 47.8mm)

6653 2 705-12

102094AE

Patch Plus 24-port, six 4-port increments (front)

11/11

Copper Connectivity Solutions Category 5e

Part of TEs high performance line of modular products, these blank patch panels accept all the modular
jacks and connectors available for TEs station outlets. The patch panels are designed to mount in
standard EIA 19-inch (482.6mm) racks.

w w w . ta ed .cc. oc m
om
/adc

+ 1+ -19- 59 25 -29- 39 83 -88- 08 80 08 0

11 -- 88 00 00 -- 3 6 6 - 3 8 9 1

182

Copper Connectivity Solutions Category 5e


Patch Panels

UMS/Mini Patch Panels

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

Category 5e UMS/Mini Patch Panels


6-port UMS/Mini patch panel,
Type 105, T568A/B
Quantity: 1
Includes 1 patch board on 1 base; mounts
on UMS mounting bracket in Type 105
position, Type 105 rod mount bracket, Type
105 back mount frame

1.73" x 4.77" x 2.08"

6653 1 607-00

11/11

102094AE

TrueNet Structured Cabling

6-port UMS/Mini Patch Panel, Type 105

www.te.com/adc

+1-952-938-8080

1-800-366-3891

183

Copper Connectivity Solutions Category 5e

Combine UMS/Mini Patch Panels with Ultim8


or feed-through blocks for complete patching
flexibility.

Copper Connectivity Solutions Category 5e


Modular Jacks

K610 Series Jacks

TrueNet Structured Cabling

The K610 series jacks can be used in TEs


modular patch panels.
K610 Series jack

Features
Available in right angle style
Compatible with any TrueNet modular
faceplate, modular furniture faceplate,
surface box and modular patch panel
Available in eleven colors for easy port
identification
Accept either KRONE or 110 tool for
termination

Color

RJ45 T568A/B
Right Angle
6467 5 181-20
6467 5 181-10
6467 5 181-00
6467 5 181-30
6467 5 181-50
6467 5 181-40
6467 5 181-80
6467 5 181-90
6467 5 181-70
6467 5 181-60
6467 5 181-22

White
Ivory
Gray
Black
Red
Blue
Green
Yellow
Purple
Orange
Electrical Ivory

RJ45 USOC
Right Angle
6467 5 198-20
6467 5 198-10
6467 5 198-00
6467 5 198-30
6467 5 198-50
6467 5 198-40
6467 5 198-80
6467 5 198-90
6467 5 198-70
6467 5 198-60
6467 5 198-22

RJ11 USOC
Right Angle
6467 5 195-20
6467 5 195-10
6467 5 195-00
6467 5 195-30
6467 5 195-50
6467 5 195-40
6467 5 195-80
6467 5 195-90
6467 5 195-70
6467 5 195-60
6467 5 195-22

102094AE

K610 series jacks are an integral part of the


TrueNet channel solution. Tuned together with
other TrueNet Category 5e components and
cable, K610 jacks help deliver zero bit error
network performance.

11/11

Copper Connectivity Solutions Category 5e

www.te.com/adc

+1-952-938-8080

1-800-366-3891

184

Copper Connectivity Solutions Category 5e


Patch Cords
Patch Cords

Before ordering patch cords, check the transmit


and receive orientation of the hub and network
interface card. Some manufacturers require
a crossover of transmit and receive pairs; others
have either the hub port or NIC card reversed
in advance. Some can switch between the two.
Please contact the TE Technical Assistance Center
with questions.
Ordering Information
Description

Cable Color

RJ45 plug to RJ45 plug, T568B,


wired straight through Quantity: 1
RJ45 plug (T568B)

RJ45 plug (T568A)

White
Red
Blue
Green
Yellow
Gray

TP5ETA0WTXX
TP5ETA0RDXX
TP5ETA0BLXX
TP5ETA0GNXX
TP5ETA0YLXX
TP5ETA0GYXX

RJ45 plug (T568A)

White
Red
Blue
Green
Yellow
Gray

TP5ETACWTXX
TP5ETACRDXX
TP5ETACBLXX
TP5ETACGNXX
TP5ETACYLXX
TP5ETACGYXX

RJ45 plug to RJ45 plug, T568A,


wired straight through Quantity: 1

RJ45 plug to RJ45 plug,


crossover wired Quantity: 1
RJ45 plug (T568B)

*Replace XX with:

04 = 4'
07 = 7'

10 = 10'
15 = 15'

25 = 25'
50 = 50'

11/11

102094AE

TP5ETA-WTXX
TP5ETA-RDXX
TP5ETA-BLXX
TP5ETA-GNXX
TP5ETA-YLXX
TP5ETA-GYXX

RJ45 plug (T568B)

RJ45 plug (T568A)

Catalog Number*

White
Red
Blue
Green
Yellow
Gray

www.te.com/adc

+1-952-938-8080

1-800-366-3891

185

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

These RJ45 (8P8C) plug to RJ45 plug patch


cords use TE Category 5e cable and exceed the
requirements for Category 5e.

Copper Connectivity Solutions Category 5e


Patch Cords

TrueNet Structured Cabling

Features
Exceeds TIA/EIA Category 5e requirements
Cable assemblies are available in riser or
plenum solid horizontal cable versions
Durable design to be in operation beyond
20-year product warranty
Impedance matched patch cord for
maximum throughput
Flexible strain relief boot maintains proper
bend radius to ensure peak performance
Plug to jack cable assemblies utilizes TEs
K610 5e jack and LSA-PLUS 45 degree angle
IDC design
Up to 28 percent smaller outer diameter than
other patch cords
UL 1863 listed and Category 5e performance
verified

102094AE

Impedance matched for use in TrueNet


structured cabling systems; these specialty patch
cords exceed all performance requirements
for Category 5e. The plug is designed with
integrated strain relievers that prevent the cable
from moving at the termination point when the
cable is flexed, safeguarding circuit integrity and
guaranteeing maximum performance. The strain
relievers also ensure that proper bend radii are
maintained throughout the network. These cords
are available in plenum or riser versions to meet
all requirements within the LAN and Data Center
environment. The specialty cable assemblies
are available in plug to plug or jack to plug
configuration for ease of installation in a data
center or a zone cabling application.

11/11

Copper Connectivity Solutions Category 5e

Category 5e Specialty Patch Cords

www.te.com/adc

+1-952-938-8080

1-800-366-3891

186

Copper Connectivity Solutions Category 5e


Patch Cords

Category 5e Specialty Patch Cords

Operating Temperature Range:


RJ45 Plug Interface According to:
Transmission Performance and Reliability:
Number of Plug Insertion Cycles:
Conductor:
Nominal Outer Diameter:
Safety Rating:
Flammability Rating:

-10 to 60 C (14 to 140 F)


IEC 60603-7
TIA/EIA 568-B.2-1 Category 5e
ISO 11801 Class D standard
750 (IEC/EN 60603-7)
24 AWG
4.57mm (.180") Plenum and 4.7mm (.185") Riser
UL 1863
UL 94 V-0

Note: See TrueNet Category 5e Plenum and Riser data sheets for additional detail for cable specifications.

Ordering Information
Description

Catalog Number

Patch Cords R45 Plug to RJ45 Plug


C5e UTP RJ45 plug to RJ45 568A plug Riser Patch Cord

TP5ETAR0XXYY

C5e UTP RJ45 plug to RJ45 568B plug Riser Patch Cord

TP5ETAR-XXYY

C5e UTP RJ45 plug to RJ45 568A plug Plenum Patch Cord

TP5ETAP0XXYY

C5e UTP RJ45 plug to RJ45 568B plug Plenum Patch Cord

TP5ETAP-XXYY

Sub XX for color: BL=Blue, BK=Black, GY=Gray, RD=Red, GN=Green, YL=Yellow, WT=White
Sub YY for length: 04= 4 feet, 07= 7 feet, 10=10 feet, 15=15 Feet, 25=25 feet, 50=50 feet
Call TE for additional colors and lengths

Ordering Information
Description

Catalog Number

102094AE

Call TE for additional lengths

11/11

Sub XX for color: BL=Blue, BK=Black, GY=Gray, GN=Green, IV=Ivory, RD=Red, YL=Yellow, WT=White, OR=Orange, VT= Violet
Sub YY for length: 07= 7 feet, 15=15 Feet, 25=25 feet, 30= 30 feet, 35= 35 feet 50=50 feet

Patch Cords R45 Plug to RJ45 Jack


C5e UTP RJ45 plug to RJ45 jack 568A Riser Patch

TP5ETAJ0XXYY

C5e UTP RJ45 plug to RJ45 jack 568B Riser Patch

TP5ETAJ-XXYY

C5e UTP RJ45 plug to RJ45 jack 568A Plenum Patch Cord

TP5ETAJP0XXYY

C5e UTP RJ45 plug to RJ45 jack 568B Plenum Patch Cord

TP5ETAJP-XXYY

Plenum cable assemblies use blue cable and riser cable assemblies use white cable. Only the K610 jack color will change.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

187

Copper Connectivity Solutions Category 5e

TrueNet Structured Cabling

Specifications

T1 Demarcation Modular Patch Panels ........................... 191


RJ45 Coupler Panel ........................................................ 192
Fast Ethernet Patch Panels ............................................. 193
25-Pair Cable Assemblies ............................................... 194
Highband 10 Collocation Block Systems ....................... 195
Feed-Thru (FT) Termination Block Systems ...................... 197
Feed-Thru (FT) Field Assembly Kits ................................. 199
Patch Cords for Feed-Thru (FT) Blocks ............................ 201
Feed-Thru (FT) Block Test Shoe Harness.......................... 203
Feed-Thru (FT) Block Test Cord ....................................... 203

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

189

Copper Connectivity Solutions Specialty Products

Ethernet Test Access Panel ............................................. 190

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions


Specialty Products

Copper Connectivity Solutions


Specialty Products

TrueNet Structured Cabling

The Ethernet test access panel allows noninvasive testing and monitoring of Ethernet
signals up to and including Gigabit Ethernet.
As carrier and enterprise networks deploy critical
data services, the need to provide noninvasive
points for testing and monitoring becomes a
critical element of network design. TEs solution
features standard RJ45 interfaces in a 24-port
two rack space high panel with a make-beforebreak (MBB) connector in-line with the Ethernet
circuit. A number of value-added modules can
be inserted into the MBB connector, including
a look-both-ways test access cord with a
standard RJ45 output that can be plugged
into any standard Ethernet test set or intrusion
detection system (IDS).

Features

Applications

High-density: 24 ports in two rack spaces

Test and turn-up of new Ethernet services

Standard RJ45 patch panel interface

Performance monitoring of existing


Ethernet lines

Standard RJ45 test access cord attaches to


any Ethernet test system

Intrusion detection systems (IDS)

Make-before-break connector allows


Ethernet circuit to be accessed, re-routed,
protected, or monitored without disrupting
existing cabling

10/100Base-T Ethernet
Gigabit Ethernet (1000Base-T)
T1/E1

Mounts in 19- and 23-inch WECO or EIA


racks; can also be wall mounted

102094AE

Category 5e performance

11/11

Copper Connectivity Solutions Specialty Products

Ethernet Test Access Panel

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

24-port RJ45 to RJ45 test access panel,


2RU

3.5" x 17.2" x 3"


(88.9mm x 436.88mm x 76.2mm)

ADCPP24-DRJ

24-port RJ45 to RJ45 test access panel,


2RU: All front access (inputs and outputs
on front of panel only)

3.5" x 17.2" x 3"


(88.9mm x 436.88mm x 76.2mm)

ADCPP24-DFRJ

Ethernet test access cord

www.te.com/adc

ADCDM-TEST

+1-952-938-8080

1-800-366-3891

190

Copper Connectivity Solutions


Specialty Products
T1 Demarcation Modular Patch Panels

Features
Bantam nonintrusive T1 signal
monitoring (MPP-N28BA1 only)
RJ48X (T1 loopback) or RJ45C
(no loopback) wiring

Copper Connectivity Solutions Specialty Products

MPP-N28BA1 (front)

Variety of rear termination options


(wire-wrap, 64-pin, 50-pin)
Category 3 performance
Variety of mounting options (19- or
23-inch rack mounting, wall mounting)
MPP-N28BA1 (rear)

Compatible with industry standard RJ45


patch cords

Shorting Bar

Pair 1

Pair 1

Pair2

MPP-CXFBA1 (front)

Pair2

12 34 5 6 78

12 34 5 6 78

RJ48x

RJ48C

RJ48X has a shorting bar between transmit and


receive pins 1, 2 and 4, 5 to allow for T1 signal loopback when no patch cord is present. The RJ48C has no
shorting bar.

Rear Termination

EIA Mounting

Catalog Number

28 (with bantam RJ48X


monitoring ports)

64-pin or wire-wrap

2RU x 19" or 23"

MPP-N28BA1

Ordering Information

28

RJ48X

Wire-wrap

1RU x 19" or 23"

MPP-GDXBA1

11/11

102094AE

TrueNet Structured Cabling

TE modular T1 demarcation patch panels feature RJ48X or RJ48C wiring with a variety of rear termination options. The T1 demarcation patch panels offer end users a familiar RJ interface by which the T1
signal can be accessed via industry standard RJ45 patch cables.

Port Count

28

RJ48X

64-pin

1RU x 19"

MPP-DXZBA0

14

RJ48X

Wire-wrap, front access

Wall mount, 3.5" x 19"

MPP-CXZXF4

RJ48X

Wire-wrap, front access

Wall mount, 3.5" x 14"

MPP-CXZXF3

RJ48X

Wire-wrap, front access

Wall mount, 3.5" x 9.9"

MPP-CXZXF2

28

RJ48C

Wire-wrap

1RU x 19" or 23"

MPP-GDXBA2

24

RJ48C shielded

50-pin shielded

1RU x 19"

MPP-CXFBA1-S

24

RJ48C

50-pin

1RU x 19"

MPP-CXFBA1

32

RJ48C

50-pin

1RU x 19"

MPP-CXZXBT2A

www.te.com/adc

Wiring

+1-952-938-8080

1-800-366-3891

191

Copper Connectivity Solutions


Specialty Products

RJ45 coupler panel (rear view)

RJ45 coupler panel (front view)

Ordering Information
Description
RJ45
coupler panel

Port Count

Category

Rack Units

24
48
24
24
24
48
16
32

6
6
Shielded 6
Shielded 5e
5e
5e
5e
5e

1
2
1
1
1
2
1
1

Catalog Number
ADCPP24606
ADCPP48606
ADCPP24RJ6-S
ADCPP24RJ5E-S
ADCPP24505
ADCPP48505
ADCPP16KSRJRJ
ADCPP32KSRJRJ

102094AE

TrueNet Structured Cabling

TEs RJ45 coupler panel provides feed-through


data and voice connectivity on the front and rear
for Category 5e and 6 applications. Connectivity
on the front of the panel accommodates standard
RJ45 patch cords. Connectivity for hubs, routers
and other active equipment on the back of the
panel is also designed for RJ45 patch cords
creating a convenient connection field for data
applications. Includes port labeling for front and
rear. Width is 48.26cm (19-inch).

11/11

Copper Connectivity Solutions Specialty Products

RJ45 Coupler Panel

www.te.com/adc

+1-952-938-8080

1-800-366-3891

192

Copper Connectivity Solutions


Specialty Products
Fast Ethernet Patch Panels

Durable, quality construction for


maximum performance
Saves time in moves, adds, and changes
Features secure and convenient 25-pair connections on the rear
Modular 8-pin, 4-pair jacks on the front
5800 has all pairs wired
Includes write-on labels on front
5100 supports 10Base-T and 100Base-T
Ethernet
5800 supports 10/100 and 1000Base-T
Ethernet
Optional icons speed circuit identification

The first step to integrate Fast Ethernet traffic into a twisted pair network is to terminate both station
side and equipment side connections on high performance TE patch panels.
For the Ethernet switching system, 5100 and 5800 patch panels provide convenient 25-pair (50-pin)
female RJ21x connections on the rear, with rugged 8-pin modular jacks on the front. Port identification
is accomplished with write-on port labels and optional icons.
Ordering Information
Description

Pin-out

Port Count

Rear Connector

Rack Units

5100
5100
5800
5800

1, 23, 6
1, 23, 6
18
18

24
48
24
48

RJ21x
RJ21x
RJ21x
RJ21x

2
2
1
2

1-800-366-3891

patch
patch
patch
patch

panel
panel
panel, T568B
panel, T568B

Catalog Number
ADCPP245100TEL
ADCPP485100TEL
ADCPP245800BTEL
ADCPP485800BTEL

DIMENSIoNS (W x H)
1RU
19.0" x 1.75" (48.26 x 4.45cm)
2RU
19.0" x 3.50" (48.26 x 8.89cm)

11/11
www.te.com/adc

+1-952-938-8080

193

Copper Connectivity Solutions Specialty Products

5100 patch panel, 48-port

5100 pin-out is 1, 23, 6

102094AE

TrueNet Structured Cabling

Features

Copper Connectivity Solutions


Specialty Products
25-Pair Cable Assemblies
Features

TrueNet Structured Cabling


102094AE

Connectors available in:


- 180 exit angle
- Hydra terminated with twelve
numbered RJ45 plugs
Exceeds Category 5 PowerSum requirements
Supports 10Base-T and 100Base-T Ethernet

The 25-pair cable assemblies are Category 5 PowerSum telco cables that provide precise connectivity
between Fast Ethernet switches and 5100 or 5800 Patch Panels.
With the convenience and precision of RJ21x connectors, 25-pair cable assemblies easily handle even
high density Fast Ethernet switch configurations. In addition, the durable connectors feature a lockdown system that eliminates intermittency often associated with other telco cables.

RJ21x/RJ21x
Ordering Information
Description
25-pair cable
assemblies

Connector 1
Straight Exit 180

Connector 2

Catalog Number

Straight Exit 180

ADCPC-T3T3-5100-XX*

*Replace the XX in the ordering number with desired length in feet: 05, 10, 15, 20, 25, 30, 35, 40, 45, or 50 feet.

RJ21x/Hydra
Ordering Information
Description
25-pair cable
assemblies

11/11

Copper Connectivity Solutions Specialty Products

Convenient 25-pair/50-pin RJ21x connections

Connector 1

Connector 2

Catalog Number

Straight Exit 180


Straight Exit 180
Straight Exit 180

Hydra, longest to shortest plug: 112


Hydra, longest to shortest plug: 121
Hydra, plugs same length

ADCPC-T3H1-5100-XX*
ADCPC-T3H2-5100-XX*
ADCPC-T3H3-5100-XX*

Note: Hydra connectors consist of 12 RJ45 plugs pinned 1,23,6.


*Replace the XX in the catalog number with desired length in feet: 06, 10, or 15 feet.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

194

Copper Connectivity Solutions


Specialty Products

HighBand 10 collocation blocks are preterminated to industry standard 25-pair (RJ-21X) connectors
mounted on the rear of the back mount frame for fast broadband/DSL service deployment. The 25-pair
connectors are oriented for top feed cable assemblies. Available in either 100-, 200- or 300-pair, these
blocks are ideal for use with TE cable for a complete broadband/DSL transmission solution.

Features

High-density IDC termination system


Provides look-both-ways fault isolation,
testing and qualification without
removing wires
Patching provides the versatility required for
easy changes and testing
Preterminated versions reduce
installation time
Numerous labeling options allow for
comprehensive marking

100-pair HighBand 10 collocation block

11/11

200-pair HighBand 10 collocation block

300-pair HighBand 10 collocation block

ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

195

Copper Connectivity Solutions Specialty Products

Superior network performance and


throughput

102094AE

TrueNet Structured Cabling

HighBand 10 Collocation Block Systems

Copper Connectivity Solutions


Specialty Products
HighBand 10 Collocation Block Systems
Ordering Information
Catalog Number

100-pair preterminated to (4) 25-pair


female telco (RJ-21X) connectors

9.63" x 4.88" x 3.69"


(244.5mm x 123.8mm x 93.7mm)

6637 1 150-60

200-pair preterminated to (8) 25-pair


female telco (RJ-21X) connectors

18.44" x 4.88" x 3.69"


(468.0mm x 123.8mm x 93.7mm)

6637 1 180-60

300-pair preterminated to (12) 25-pair


female telco (RJ-21X) connectors

27.13" x 4.88" x 3.69"


(689.0mm x 123.8mm x 93.7mm)

6637 1 210-60

102094AE

TrueNet Structured Cabling

Dimensions (HxWxD)

HighBand 10 collocation block systems


Quantity: 1

11/11

Copper Connectivity Solutions Specialty Products

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

196

Copper Connectivity Solutions


Specialty Products

2. Move base unit from


bottom to top

3. Flip and snap into place

Features
Appropriate for both data and voice
application
High-density and quick installation are the
hallmarks of the 25-pair Feed-Thru (FT)
block system

25-pair FT block, 5-pair color-coded

Convenient preterminated assemblies with


50-pin telco connectors provide for fast,
reliable termination
The 25-pair FT block is the perfect
replacement for 110 installations
Complete patching and cross-connect
options provide the versatility required for
any configuration
Color-coded blocks are offered, with
each pair color marked according to
industry standards

25-pair FT block, 4-pair color-coded

Handy label holders provide clear


identification of groups or individual pairs

11/11

Type 160 hinged label holder

ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

197

Copper Connectivity Solutions Specialty Products

1. Terminate cables

102094AE

TrueNet Structured Cabling

Feed-Thru (FT) Termination Block Systems

Copper Connectivity Solutions


Specialty Products
Feed-Thru (FT) Termination Block Systems
Ordering Information

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Specialty Products

Description

Dimensions (HxWxD)

Catalog Number

25-pair FT block Quantity: 1


4-pair color-coded
Allows high-density termination in small
area; two-piece assembly, consisting of base
and connector. 4-pair color-code marked on
face of block. Used for terminating 4-pair
station cables; each block terminates
(6) 4-pair cables

1" x 8.75" x 1.88"


(25.4mm x 225.3mm x 47.6mm)

6631 2 135-05

5-pair color-coded
Allows high-density termination in small
area; two-piece assembly, consisting of base
and connector. 5-pair color-code ( blue,
orange, green, brown, slate) marked on face
of block. Used for terminating 25-pair cable

1" x 8.75" x 1.88"


(25.4mm x 225.3mm x 47.6mm)

6631 2 135-06

5-pair coded
Allows high-density termination in small
area; two-piece assembly, consisting of base
and connector. Marked in white every fifth
pair. Used for terminating riser cables or
with PBX systems. Each block terminates
25-pair

1" x 8.75" x 1.88"


(25.4mm x 225.3mm x 47.6mm)

6631 2 135-00

Type 160 hinged label holder


Used on 25-pair FT block to identify cable
groups or individual pairs; folds out of the
way when punching down wires; can be
used for 1- to 25-pair configurations
Quantity: 1

6631 2 003-00

Label sheets for Type 160 hinged label


holder
Each 8.5" x 11" sheet contains 34 perforated
labels Quantity: 1 sheet per package
Blue and white
One side is blue and marked in 4-pair
increments; other side is white and marked
in 5-pair increments

6631 3 100-26

Back (White)

Front (Blue)

Gray/brown

6631 3 100-22

Yellow/red

6631 3 100-23

orange

6631 3 100-27

Purple

6631 3 100-28

Blue

Type 160 Hinged

Green

6631 3 100-29
6631 3 100-30

For examples of TIA/EIA color-coding, refer to the chart on page 234.

Tech Tip
Labeling templates are available in Microsoft Word and Excel formats.
Please contact TE Technical Assistance Center

www.te.com/adc

+1-952-938-8080

1-800-366-3891

198

Copper Connectivity Solutions


Specialty Products
Feed-Thru (FT) Field Assembly Kits

Wall mount
Wall mount with optional UMS backboard
for greater cabling depth
Rack mount with UMS backboard

Copper Connectivity Solutions Specialty Products

FT field assembly kits include a universal


mounting bracket, two horizontal wire managers
and a choice of 4-pair or 5-pair color-coded FT
blocks. Route cable from the top, bottom or
rear. Four-pair color-coded blocks are marked
with TIA color codes in 4-pair groups. Five-pair
coded blocks are marked with a white stripe on
every fifth pair. Labeling accessories, such as label
holders and paper labels, are sold separately
(see pages 231235)

300-pair FT field assembly kit

ordering information follows on the next page

11/11

102094AE

TrueNet Structured Cabling

The FT field assembly kits feature the universal


mounting system, which provides modularity and
three mounting options

www.te.com/adc

+1-952-938-8080

1-800-366-3891

199

Copper Connectivity Solutions


Specialty Products
Feed-Thru (FT) Field Assembly Kits
Ordering Information

TrueNet Structured Cabling

Catalog Number

100-pair, 4-pair color-coded kit


Includes (4) 25-pair FT blocks with 4-pair
color-coding, 2 horizontal wire managers,
1 universal mounting bracket. Terminates
(24) 4-pair station cables. Hinged label holders
for identification of stations or pairs
ordered separately

14.75" x 10.75" x 5.25"


(374.7mm x 273.1mm x 133.4mm)

6642 1 115-04

100-pair, 5-pair color-coded kit


Includes (4) 25-pair FT blocks with 5-pair
code marked on face of block, 2 horizontal
wire managers, 1 universal mounting bracket.
Hinged label holder for identification of
stations or pairs ordered separately

14.75" x 10.75" x 5.25"


(374.7mm x 273.1mm x 133.4mm)

6642 1 115-05

300-pair, 4-pair color-coded kit


Includes (12) 25-pair FT blocks with 4-pair
color-coding, 2 horizontal wire managers,
1 universal mounting bracket. Terminates
(72) 4-pair station cables. Hinged label
holder for identification of stations or pairs
ordered separately

14.75" x 10.75" x 5.25"


(374.7mm x 273.1mm x 133.4mm)

6642 1 315-04

300-pair, 5-pair color-coded kit


Includes (12) 25-pair FT blocks with
5-pair code marked on face of block,
2 horizontal wire managers, 1 universal
mounting bracket. Hinged label holder for
identification of stations or pairs
ordered separately

14.75" x 10.75" x 5.25"


(374.7mm x 273.1mm x 133.4mm)

6642 1 315-05

FT field assembly kits

102094AE

Dimensions (HxWxD)

11/11

Copper Connectivity Solutions Specialty Products

Description

Tech Tip
When installing 25-pair FT blocks, it is easier to lace the wire from bottom to top, terminate the field from
top to bottom, then flip all blocks in that field.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

200

Copper Connectivity Solutions


Specialty Products
Patch Cords for Feed-Thru (FT) Blocks

11/11

Ordering Information
Description

Cable Color

4-pair FT plug to FT plug, wired straight through Quantity: 1


Pair No.
Pair 4
Pair 3
Pair 2
Pair 1

R
T
R
T
R
T
R
T

4-pair FT plug to RJ45 (8P8C) plug, wired T568A Quantity: 1


Wired to
Pin #
8
7
2
1
6
3
4
5

Pair No.
Pair 4
Pair 3
Pair 2
Pair 1

R
T
R
T
R
T
R
T

*Replace XX with: 04
07
10
15
25
50

=
=
=
=
=
=

Catalog Number*

White

TP5ETF-WTXX

Red

TP5ETF-RDXX

Blue

TP5ETF-BLXX

Green

TP5ETF-GNXX

Yellow

TP5ETF-YLXX

Gray

TP5ETF-GYXX

White

TP5ETB0WTXX

Red

TP5ETB0RDXX

Blue

TP5ETB0BLXX

Green

TP5ETB0GNXX

Yellow

TP5ETB0YLXX

Gray

TP5ETB0GYXX

4'
7'
10'
15'
25'
50'

ordering information continues on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

201

Copper Connectivity Solutions Specialty Products

102094AE

TrueNet Structured Cabling

These FT patch cords use TE Category 5e cable and exceed the requirements for Category 5e.

Copper Connectivity Solutions


Specialty Products
Patch Cords for Feed-Thru (FT) Blocks
Ordering Information

TrueNet Structured Cabling

Wired to
Pin #
8
7
6
3
2
1
4
5

White

Pair No.
Pair 4
Pair 3
Pair 2
Pair 1

R
T
R
T
R
T
R
T

1-pair FT plug to FT plug, wire straight through Quantity: 1


Pair No.
Pair 1

Pair No.
Pair 1

Red

TP5ETB-RDXX

Blue

TP5ETB-BLXX

Green

TP5ETB-GNXX

Yellow

TP5ETB-YLXX

White

6645 2 251-XX

Red

6645 2 264-XX

Blue

6645 2 265-XX

White

6645 2 266-XX

R
T

2-pair FT plug to FT plug, wired straight through Quantity: 1

Pair 2

Catalog Number*
TP5ETB-WTXX

Red

6645 2 267-XX

Blue

6645 2 268-XX

R
T
R
T

*Replace XX with: 04
07
10
15
25
50

=
=
=
=
=
=

4'
7'
10'
15'
25'
50'

102094AE

Color Cable

4-pair FT plug to RJ45 (8P8C) plug, wired T568B Quantity: 1

11/11

Copper Connectivity Solutions Specialty Products

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

202

Copper Connectivity Solutions


Specialty Products
Feed Thru (FT) Block Test Harness
Ordering Information
Catalog Number

1" x 8.75" x 1.88"


(25.4mm x 225.3mm x 47.6mm)

6631 2 050-01

Copper Connectivity Solutions Specialty Products

Dimensions (HxWxD)

25-pair FT test harness


Use with 25-pair FT blocks to test all 25 pairs
at once. Features 50-pin female connector
with hook-and-loop fastener lock; fits a
variety of test equipment Quantity: 1

Feed Thru (FT) Block Test Cord


Ordering Information
Description

Catalog Number

FT block test cord

6645 2 254-01

1-pair FT connector to 2
banana plugs (connect to
test equipment), 1' length.
Used to bridge or monitor
circuit Quantity: 1
FT test cord

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

203

Ethernet Distribution Frame ........................................... 206


Vertical and Horizontal Cable Management ................... 207
Universal Mounting System............................................ 213
Back Mount Frames ....................................................... 218
Rod Mount Frames ........................................................ 221

Support Bars .................................................................. 224


Inverted Support Bars .................................................... 225
Jumper Ring Bars ........................................................... 226
Accessories .................................................................... 227

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

205

Copper Cable Management Solutions

Mounting Frames .......................................................... 223

102094AE

TrueNet Structured Cabling

Copper Cable Management Solutions

Copper Cable Management Solutions


Ethernet Distribution Frame

All changes, circuit rerouting, upgrades, maintenance and other activities are accomplished using
semi-permanent patch cords on the front of the EDF cross-connect bay.
Glide Cable Management Adapter
7' EIA 19" UEF Zone 4 Rack
PowerWorx Power Distribution Panel
2RU Horizontal Cable Manager

Media Converter
Fiber Management Tray
48-Port Category 5e Panel

102094AE

TrueNet Structured Cabling

All network elements have permanent equipment cable connections that are, once terminated,
never handled again.

8" Glide Cable Management

Bottom Crossover Trough

11/11

Copper Cable Management Solutions

TEs Ethernet Distribution Frame (EDF) forms a central patching location between active Ethernet
network elements. By creating a centralized craft interface for adds, upgrades, and rearrangements on
Ethernet equipment, the EDF enables change without service disruptions. This central patching location
provides a logical and easy-to-manage infrastructure due to two design characteristics:

www.te.com/adc

+1-952-938-8080

1-800-366-3891

206

Copper Cable Management Solutions


Vertical and Horizontal Cable Management
Glide Cable Manager

Upper and lower crossover managers


with vertical cable managers enable easy,
intuitive cable routing.

Integrated front, rear, horizontal, and


vertical cable management

Optional slack managers available for


6-, 8-, 10-, and 12-inch widths

Patented rib cage design eliminates horizontal


support trays and bars

Fits standard EIA rack with three-inch channel

Supports up to 912 ports on a single rack

Optional crossover troughs and horizontal


cable managers available

Built-in bend radius protection ensures


network integrity
Designed for quick and easy moves, adds,
and changes

Used for single rack or as inter-rack unit

Optional EIA-standard horizontal support


bars available

5/08
www.te.com/adc

+1-952-938-8080

1-800-366-3891

207

Copper Cable Management Solutions

Features

102094AE

TrueNet Structured Cabling

Copper Cable Management Solutions


Vertical and Horizontal Cable Management
Glide Cable Manager

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Management Solutions

Ordering Information
Description

Catalog Number

Glide cable manager, vertical mount


to equip both sides of a 7-foot rack, order
two Glide Cable Manager units
6", front only, without slack manager
6", front only, with slack manager
6", without slack manager
8", without slack manager
10", without slack manager
12", without slack manager
6", with slack manager
8", with slack manager
10", with slack manager
12", with slack manager
Crossover trough, 2RU
Crossover trough, 4RU

ADCCMVIB06F-2
ADCCMVIBS06F-2
ADCCM-06
ADCCM-08
ADCCM-10
ADCCM-12
ADCCMS-06
ADCCMS-08
ADCCMS-10
ADCCMS-12
ADCCMTG02
ADCCMTG04

Hinged black metal cover kits:


to equip both sides of a 7' rack (front and
back), order 2 cover kits.
41" x 6"
41" x 8"
41" x 10"
41" x 12"

ADCCMVIBC06B4
ADCCMVIBC08B4
ADCCMVIBC10B4
ADCCMVIBC12B4

Hinged black metal cover kits:


to equip both sides of a 7' rack (front only),
order 2 cover kits. These covers are for
Glide Cable Managers TECMVIB06F-2 and
TECMVIBS06F-2 only.
41" x 6", two per pack

Glide Cable Manager


shown in cabinet

Cover in black metal

ADCC06-2

Ordering Information
Description

Catalog Number

Glide cable manager, cabinet mount


ships 4 per pack
6" x 10RU
6" x 20RU

ADCCMVIB-CB10-4
ADCCMVIB-CB-4

Glide cable manager, cabinet mount,


with cable retentionships 4 per pack
3" x 20RU
6" x 20RU

ADCCMVIB-3CB20-4
ADCCMVIB-6CB20-4

Notes: Equips standard 7' cabinet with front or rear cable management.
Order two 4-packs to equip front and rear of cabinet.

www.te.com/adc

+1-952-938-8080

Glide Cable Manager,


cabinet mount

1-800-366-3891

208

Copper Cable Management Solutions


Vertical and Horizontal Cable Management
Glide Cable Manager
Ordering Information

11/11

Catalog Number

Crossover troughs
2RU, black
4RU, black, 23" rack
4RU, black

ADCCMTG02
ADCCMTG04-23
ADCCMTG04

Horizontal cable managers


2RU
3RU
4RU
With slack managers, 3RU
With slack managers, 4RU

ADCCMHIB-2U
ADCCMHIB-3U
ADCCMHIB-4U
ADCCMHIBS-3U
ADCCMHIBS-4U

Rear cable management bar, 19"


1" extension
Rear cable management bar, 19"
4" extension

2RU crossover trough

4RU crossover trough

Horizontal cable manager

ADCCMRSB
ADCCMRSB-4

Slack manager

ADCCMVIBSP

Stabilizers
6.18"
8.38"
10.18"
12.18"

ADCCMVESB06
ADCCMVESB08
ADCCMVESB10
ADCCMVESB12

Extender brackets, 19" to 23"


1RU
2RU
4RU

EB-17B
EB-35B
EB-70B

Stabilizer

Slack manager

Note: Stabilizer used at end of lineup for each Vertical Integrator section.

Ordering Information
Description
7' equipment racks
Self-assembly aluminum relay rack, 3" channel
Black
Brushed aluminum
Welded steel relay rack, 3" channel, black
Welded steel relay rack, Zone 4 rated, black
Unequal flange
Network unequal flange

www.te.com/adc

Spacing

Catalog Number

19" EIA
19" EIA
19" EIA

ADCRACKBLK73
ADCRACKMF73
ADCRACKBLK73WS

19" EIA
23" EIA

ADCRACKBLK73UE-75
PWUEF-7ERN-BLK

+1-952-938-8080

1-800-366-3891

209

Copper Cable Management Solutions

102094AE

TrueNet Structured Cabling

Description

Copper Cable Management Solutions


Vertical and Horizontal Cable Management
Finger Duct Front Managers

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Management Solutions

TE's Front Managers are great for organizing patch cords with modular patch panels. They fit
on a standard EIA 19" equipment rack. The managers are made of UL 94V-0 plastic and include a
snap-on cover.

Finger Duct Front Manager, 1.5"x 3"

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

1.5"x 3" Front Manager, Pack Quantity: 1

1.75" x 19" x 3.5"


(44.45mm x 482.6mm x 88.9mm)

6652 2 153-00

3"x 3" Front Manager, Pack Quantity: 1

3.5" x 19" x 3.5"


(88.9mm x 482.6mm x 88.9mm)

6652 2 330-00

Finger Duct Front and Rear Managers


These large capacity managers provide ample room for organizing both incoming cables and patch
cords with modular patch panels. They fit on a standard EIA 19" equipment rack. The managers are
made of UL 94V-0 plastic and include snap-on covers.

Finger Duct Front and Rear Manager,


3"x 3" Front and 3"x 4" Rear

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

1.5"x 3" Front Manager and


1"x 4" Rear Manager, Pack Quantity: 1

1.75" x 19" x 3.5"


(44.45mm x 482.6mm x 88.9mm)

6652 2 153-14

3"x 3" Front Manager and


2"x 4" Rear Manager, Pack Quantity: 1

3.5" x 19" x 3.5"


(88.9mm x 482.6mm x 88.9mm)

6652 2 330-24

3"x 3" Front Manager and


3"x 4" Rear Manager, Pack Quantity: 1

3.5" x 19" x 4.5"


(88.9mm x 482.6mm x 114.3mm)

6652 2 330-34

www.te.com/adc

+1-952-938-8080

1-800-366-3891

210

Copper Cable Management Solutions


Vertical and Horizontal Cable Management

TE's Vertical Cable Manager mounts between


standard 7' equipment racks to provide neat and
orderly routing of cables and jumpers.

Vertical Cable
Manager, 35" tall

11/11

Vertical Cable
Manager, 83" tall

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

4"x 5" Front and 4"x 5" Rear Manager,


35" Tall, Pack Quantity: 1

34.6" x 4" x 5"


(878.84mm x 101.6mm x 127.0mm)

6652 2 452-35

4"x 5" Front and 4"x 5" Rear Manager,


83" Tall, Pack Quantity: 1

34.6" x 4" x 5"


(878.84mm x 101.6mm x 127.0mm)

6652 2 452-83

www.te.com/adc

+1-952-938-8080

1-800-366-3891

211

Copper Cable Management Solutions

Each Vertical Cable Manager includes two


covers, front and rear. The fingers in the channel
are spaced to provide easy entrance and exit
of cables while still maintaining control of the
cable bend radii. For increased accessibility, the
fingers break away, leaving a smooth edge for
the protection of cable jackets. Mounting
brackets are included.

102094AE

TrueNet Structured Cabling

Vertical Cable Manager for


7' Equipment Racks

Copper Cable Management Solutions


Termination Block Mounting Hardware
Introduction

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Management Solutions

Mounting hardware is available for either wall or rack mount applications. Included is a full range of
mounting system hardware and backboards, cable management hardware, mounting frames and support
bars, as well as comprehensive fiber optic cable raceway systems for overhead and Plenum applications.
To better understand how the hardware can be utilized, the reference guide on this page gives
appropriate use information. The icons shown within the reference chart represent the
following equipment:

= Universal Mounting System (UMS)

= Type 105 Rod Mount Bracket

= Type 89D Mounting Bracket

= Type 85 Back Mount Frame

= Type 85 Rod Mount Bracket

= Type 105 Back Mount Frame

89D

Features
Various options provide flexibility
Fit standard 19-, 23- and 35.5-inch
equipment racks
Mounting hardware and backboards available
for either wall or rack mounting
Wire management built-in, or available
as accessories
Most ADC blocks have a minimum
of two mounting options

89D

Block/Patch Panel
Ultim8 Block
HighBand 10-Pair Block
Feed-Thru (FT) Block
Series 2 Block, 8-Pair
Series 2 Block,10-Pair
25/50-Pair Block
UMS/Mini Patch Panel,
Type 105

www.te.com/adc

+1-952-938-8080

1-800-366-3891

212

Copper Cable Management Solutions


Termination Block Mounting Hardware
Universal Mounting System (UMS)

The mounting brackets interlink left-to-right and top-to-bottom to provide a foundation that is easy
to install and easy to expand. The brackets are suitable for both rack and wall mount installations.
For fast installation, use the push rivets provided with the UMS backboard to attach the UMS brackets
to the backboards.

UMS In Type 105 position

UMS In Type 160 position


The UMS easily expands from the
Type 105 position to the Type 160 position.

11/11

102094AE

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

14.75" x 8.25 x 5.25"


UMS Basic Kit
(374.7mm x 209.6mm x 133.4mm)
Includes one pair of adjustable universal
mounting brackets (holds up to 13 Ultim8
blocks and/or label holders), two horizontal
wire managers, and appropriate screws and
rivets. Typical installation holds 96 pairs using
(12) 8-pair Ultim8 blocks (24-ports) and (1)
Type 105 label holder. Kit mounts directly to
a wall, or to an optional rack or wall mount
backboard. Quantity: 1
UMS Basic Kit; Black

6657 2 165-40

UMS Basic Kit; Gray

6657 2 165-00

www.te.com/adc

+1-952-938-8080

1-800-366-3891

213

Copper Cable Management Solutions

TrueNet Structured Cabling

The Universal Mounting System accepts Ultim8, HighBand 10, 10-pair Series 2, and 25-pair FT
(Feed-Thru) blocks and UMS/Mini patch panels. It is a rugged, low cost, versatile alternative to traditional
mounting systems. Besides providing a sturdy, easy-to-install interlinking foundation, the UMS features
built-in wire and cable management, and convenient add-ons.

Copper Cable Management Solutions


Termination Block Mounting Hardware

Vertical cable manager

Connect here for


Ultim8 blocks
19" equipment rack
with three dual height
backboards, each
holding four Type 105
Universal Mounting
Brackets and
two vertical cable
managers (1,152 pairs
or 288 ports).

Connect here for 25-pair


FT blocks

102094AE

TrueNet Structured Cabling

Horizontal wire manager


Individual ribs on
the vertical cable
manager remove to
provide additional
room for routing patch
cords or cables.

Ordering information follows on the next page

11/11

Copper Cable Management Solutions

Universal Mounting System (UMS) Cable and Wire Managers

Tech Tip
When connecting two UMS brackets, use the inner slot for HighBand blocks or 10-pair Series 2
blocks (Type 105) and the outer slot for 25-pair FT blocks (Type 160).

www.te.com/adc

+1-952-938-8080

1-800-366-3891

214

Copper Cable Management Solutions


Termination Block Mounting Hardware

Universal Mounting System (UMS) Cable and Wire Managers


Ordering Information
Dimensions (HxWxD)

6657 2 005-44

UMS Vertical Cable Manager; Black

6657 2 005-04

UMS Vertical Cable Manager; Gray


5.38" x 1" x 5"
(136.5mm x 25.4m x 127.0mm)

Horizontal Wire Manager; Black

6657 2 005-43

Horizontal Wire Manager; Gray

6657 2 005-03

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

215

Copper Cable Management Solutions

Horizontal Wire Manager


Includes individual horizontal wire manager
and two nylon rivets to lock manager in position
on UMS bracket. Attaches to top or bottom of
UMS bracket. Two managers are included with
each UMS basic kit; additional managers are
spares or provide wire management along the
bottom of an installation. Quantity: 1

Catalog Number

11.88" x 8.25" x 5.25"


(301.6mm x 209.6mm x 133.4mm)

102094AE

TrueNet Structured Cabling

Description
UMS Vertical Cable Manager
Same footprint as the universal mounting
bracket in the Type 105 position; provides
additional cable management for larger
installations or for patch cords. Unique
restraining-finger design ensures cables remain
in the channel, even with the cover removed.
Interlinking tabs, left-to-right and
top-to-bottom, match interlinking tabs on
the universal mounting bracket. Quantity: 1

Copper Cable Management Solutions


Termination Block Mounting Hardware

Universal Mounting System (UMS) Backboards

TrueNet Structured Cabling

Backboards will hold combinations of mounting brackets in both Type 105 (Ultim8 and HighBand)
and Type 160 (Feed-Thru) positions. Rotate backboards with mixed types 180 to reverse the order of
mounting. Silk-screening identifies which holes to use in different mounting configurations.
Wall mount backboards provide the same mounting base as the rack mount backboards but provide
a deeper channel. They stand four inches (rather than 1.5 inches) off the wall to allow for proper cable
routing. Silk screening indicates correct installation of the UMS adjustable mounting brackets.

19" backboard, dual height


19" configurations

23" configurations

102094AE

19" backboard, single height

11/11

Copper Cable Management Solutions

UMS backboards provide a base for UMS brackets, and are available in standard equipment rack
widths. Each width is available in single or dual height, holding one or two rows of mounting brackets,
respectively. Backboards are black and match UMS brackets and cable managers.

Ordering Information
Description

Dimensions (HxWxD)

Rack Wall

Catalog Number
Black

UMS backboard

Gray

11.5" x 19" x 1.5"

6652 2 080-19

6652 2 069-19

Backboards ship

23" x 19" x 1.5"

6652 2 081-19

6652 2 070-19

one to a package

11.5" x 19" x 4"

6652 2 082-19

6652 2 067-19

23" x 19" x 4"

6652 2 083-19

6652 2 068-19

www.te.com/adc

11.5" x 23" x 1.5"

6652 2 080-23

6652 2 069-23

23" x 23" x 1.5"

6652 2 081-23

6652 2 070-23

+1-952-938-8080

1-800-366-3891

216

Copper Cable Management Solutions


Termination Block Mounting Hardware

Universal Mounting System (UMS) High Volume Cable Managers

Available in widths to match standard equipment racks, the high volume cable manager can be either
rack or wall mounted. The manager includes a back mounting plate and a set of six-inch by six-inch rings.
The number and position of rings vary to allow use of the manager with a variety of UMS configurations.
Mounting holes across the face of the mounting plate allow the position of rings to change to match
the varying widths of UMS brackets in either Type 105 or Type 160 positions.
Designed as a companion to the universal mounting system, the high volume cable manager works
in any application.

19" high volume cable manager with 4 rings, shown


mounted above 3 Type 105 mounting brackets.

102094AE

35.5" high volume cable manager with 5 rings, shown


mounted above 5 Type 105 mounting brackets.

Ordering Information
Description

11/11

35.5" cable manager with 6 rings

19" cable manager with 3 rings

Dimensions (HxWxD)

19" cable manager, black only Quantity: 1

Catalog Number

6" x 19" x 6.5"


(152.4mm x 482.6mm x 165.1mm)

3 rings

6657 2 005-19/03

4 rings

6657 2 005-19/04

23" cable manager, black only Quantity: 1

6" x 23" x 6.5"


(152.4mm x 584.2mm x 165.1mm)

3 rings

6657 2 005-23/03

4 rings

6657 2 005-23/04

35.5" cable manager, black only Quantity: 1

6" x 35.5" x 6.5"


(152.4mm x 901.7mm x 165.1mm)

4 rings

6657 2 005-35/04

5 rings

6657 2 005-35/05

6 rings

6657 2 005-35/06

6.5" cable manager, gray only; 2 rings


Quantity: 1

6.5" x 6.5" x 4.75"


(165.1mm x 165.1mm x 120.65mm)

6657 2 006-06/02

9" cable manager, gray only; 3 rings


Quantity: 1 Designed to fit directly above
UMS in Type 160 position

6.5" x 9.1" x 4.75"


(165.1mm x 231.14mm x 120.65mm)

6657 2 006-09/03

www.te.com/adc

+1-952-938-8080

1-800-366-3891

217

Copper Cable Management Solutions

TrueNet Structured Cabling

For larger installations, the high volume cable manager provides greater capacity and strength than
horizontal wire managers that attach directly to UMS brackets.

Copper Cable Management Solutions


Termination Block Mounting Hardware

Type 85 back mount frame


Note: The depth dimensions
listed are the actual depths
of mounting brackets with
no blocks installed.

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

Type 85 back mount frames Quantity: 1


6 block positions, 1 hole

5.25" x 3.31" x 2.75"


(133.3mm x 84.1mm x 69.9mm)

6654 2 350-06/1

11 block positions, 1 hole

9.63" x 3.31" x 2.75"


(244.5mm x 84.1mm x 69.9mm)

6654 2 350-11/1

21 block positions, 2 holes

18.38" x 3.31" x 2.75"


(466.7mm x 84.1mm x 69.9mm)

6654 2 350-21/2

102094AE

TrueNet Structured Cabling

Type 85 back mount frames accept 8-pair Series


2 blocks. The frames come with cable entry holes
on the back and protective rubber grommets.
Grommet holes are 1.5" (38.1mm) in diameter.
Back mount frames are made of stainless steel.

11/11

Copper Cable Management Solutions

Type 85 Back Mount Frames

www.te.com/adc

+1-952-938-8080

1-800-366-3891

218

Copper Cable Management Solutions


Termination Block Mounting Hardware

Type 105 back mount frames accept Ultim8,


HighBand 10 and 10-pair Series 2 blocks and
Type 105 UMS/Mini patch panels. The frames
come with cable entry holes on the back and
protective rubber grommets. Grommet holes
are 1.5-inches (38.1mm) in diameter. Back mount
frames are made of stainless steel.

Type 105 back mount frame


Note: The depth dimensions
listed are the actual depths
of mounting brackets with
no blocks installed.

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

6 block positions, 1 hole

5.25" x 4.06" x 2.75"


(133.3mm x 103.2mm x 69.9mm)

6655 2 450-06/1

11 block positions, 1 hole

9.63" x 4.06" x 2.75"


(244.5mm x 103.2mm x 69.9mm)

6655 2 450-11/1

21 block positions, 2 holes

18.38" x 4.06" x 2.75"


(466.7mm x 103.2mm x 69.9mm)

6655 2 450-21/2

31 block positions, 3 holes

27.13" x 4.06" x 2.75"


(689.0mm x 103.2mm x 69.9mm)

6655 2 450-31/3

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

219

Copper Cable Management Solutions

Type 105 back mount frames Quantity: 1

102094AE

TrueNet Structured Cabling

Type 105 Back Mount Frames

Copper Cable Management Solutions


Termination Block Mounting Hardware

Back mount frame


with ground lug
(21-position shown)

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

6 block positions, 1 hole

5.25" x 4.06" x 2.75"


(133.3mm x 103.2mm x 69.9mm)

6655 2 400-03

21 block positions, 1 hole

18.38" x 4.06" x 2.75"


(466.7mm x 103.2mm x 69.9mm)

6655 2 400-00

Type 105 back mount frames Quantity: 1

102094AE

TrueNet Structured Cabling

These back mount frames have a standard


2.0-inch (50mm) channel depth and come with an
attached ground lug.

11/11

Copper Cable Management Solutions

Type 105 Back Mount Frames


with Ground Lug

www.te.com/adc

+1-952-938-8080

1-800-366-3891

220

Copper Cable Management Solutions


Termination Block Mounting Hardware
Type 85 Rod Mount Brackets

Type 85 rod mount bracket

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

6 block positions

5.5" x 4.19" x 2"


(139.7mm x 106.4mm x 50.8mm)

6652 2 039-06

11 block positions

9.88" x 4.19" x 2"


(250.8mm x 106.4mm x 50.8mm)

6652 2 039-11

21 block positions

18.63" x 4.19" x 2"


(473.1mm x 106.4mm x 50.8mm)

6652 2 039-21

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

221

Copper Cable Management Solutions

Type 85 rod mount brackets Quantity: 1

102094AE

TrueNet Structured Cabling

Type 85 rod mount brackets accept 8-pair Series 2


rod mount blocks. Install rod mount brackets using
support bars, or directly to a plywood backboard.

Copper Cable Management Solutions


Termination Block Mounting Hardware

TrueNet Structured Cabling

Type 105 rod mount bracket

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

Type 105 rod mount brackets Quantity: 1


6 block positions

5.5" x 4.19" x 2"


(139.7mm x 106.4mm x 50.8mm)

6652 2 040-06

11 block positions

9.88" x 4.19" x 2"


(250.8mm x 106.4mm x 50.8mm)

6652 2 040-11

21 block positions

18.63" x 4.19" x 2"


(473.1mm x 106.4mm x 50.8mm)

6652 2 040-21

Rod Mount Bracket Spacer


Rod mount bracket spacers are optional pieces that snap over the 0.47-inch (12mm) rods to maintain
uniform distances between rod mount blocks.
Ordering Information
Description

Catalog Number

Rod mount bracket spacer Quantity: 1


0.1" (2.5mm)

6619 2 046-00

0.2" (5.0mm)

6619 2 046-01

102094AE

Type 105 rod mount brackets accept Ultim8,


HighBand 10 and 10-pair Series 2 rod mount
blocks and 105mm UMS/Mini Patch Panels.
Install rod mount brackets using support bars,
or directly to a plywood backboard.

11/11

Copper Cable Management Solutions

Type 105 Rod Mount Brackets

Tech Tip
Rod mount brackets can be easily changed from the Type 85 position to the Type 105 position (or vice versa)
by removing the four screws, moving the rods in or out, and reinstalling the screws.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

222

Copper Cable Management Solutions


Mounting Frames

19" wide mounting frame

23" wide mounting frame

35.5" wide mounting frame

Description

Dimensions (HxWxD)

Catalog Number

19" mounting frame, 3-position Quantity: 1


Supports up to (3) 21-position Type 85 or Type 105
mounting brackets; can be wall or rack mounted
(EIA standard 19" equipment rack; 3 mounting frames fit
vertically in 7' rack) with 4 mounting screws (included).
Fixed jumper routing rings included

25" x 19.38" x 4.25"


(635mm x 492.1mm x 108mm)

6652 2 100-00

23" mounting frame, 3-position Quantity: 1


Supports up to (3) 21-position Type 85 or Type 105
mounting brackets; can be wall or rack mounted
(23" equipment rack) with 4 mounting screws (included).
Fixed jumper routing rings included

25" x 24" x 4.25"


(635mm x 609.6mm x 108mm)

6652 2 114-00

23" mounting frame, 4-position Quantity: 1


Supports up to (4) 21-position Type 85 or Type 105
mounting brackets; can be wall or rack mounted
(23" equipment rack) with 4 mounting screws (included).
Fixed jumper routing rings included

25" x 24" x 4.25"


(635mm x 609.6mm x 108mm)

6652 2 113-00

35.5" mounting frame, 5-position Quantity: 1


Supports up to (5) 21-position Type 85 or Type 105
mounting brackets; can be wall or rack mounted
(23" equipment rack) with 4 mounting screws (included).
Fixed jumper routing rings included

26.5" x 35.5" x 4.25"


(673.1mm x 901.7mm x 108mm)

6652 2 101-00

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

223

Copper Cable Management Solutions

Ordering Information

102094AE

TrueNet Structured Cabling

Wall or Rack Mount Mounting Frames

Copper Cable Management Solutions


Support Bars

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Management Solutions

Wall or Rack Mount Support Bars

19" wide support bar with 4" leg

23" wide support bar, 3-position

35.5" wide support bar

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

2" leg (rack mount)

1" x 20" x 2"


(25.4mm x 508mm x 50.8mm)

6652 2 021-00

4" leg (wall mount)

1" x 20" x 4"


(25.4mm x 508mm x 101.6mm)

6652 2 023-02

1" x 24" x 4"


(25.4mm x 609.6mm x 101.6mm)

6652 2 004-56

2" leg (rack mount)

1" x 24" x 2"


(25.4mm x 609.6mm x 50.8mm)

6652 2 012-45

4" leg (wall mount)

1" x 24" x 4"


(25.4mm x 609.6mm x 101.6mm)

6652 2 012-42

2" leg (rack mount)

1" x 35.69" x 2"


(25.4mm x 906.5mm x 50.8mm)

6652 2 013-00

4" leg (wall mount)

1" x 36" x 4"


(25.4mm x 914.4mm x 101.6mm)

6652 2 014-00

19" wide support bar, 3-position Quantity: 1


2 required for installation
(2) 19" wide support bars hold up to (3) Type 85 or
Type 105 back mount frames; can be wall or rack mounted
(standard 19" equipment rack)

23" wide wall mount support bar, 3-position Quantity: 1


2 required for installation
(2) 23" wide support bars hold up to (3) Type 85 or Type 105
back mount frames
4" leg (wall mount)
23" wide support bar, 4-position Quantity: 1
2 required for installation
(2) 23" wide support bars hold up to (4) Type 85 or 105
back mount frames; can be wall or rack mounted (standard
23" equipment rack)

35.5" wide support bar, Quantity: 1


2 required for installation
(2) 35.5" wide support bars hold up to (6) Type 85 or (5)
Type 105 back mount frames; can be wall or rack mounted
(standard 35.5" equipment rack)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

224

Copper Cable Management Solutions


Inverted Support Bars

Type 85 and Type 105 Inverted Support Bars

19" wide inverted support bar,


3-position

19" wide inverted support bar,


4-position

23" wide inverted support bar,


3-position

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

3-position
Supports up to (3) Type 85 or Type 105 mounting brackets

1" x 20" x 4"


(25.4mm x 508mm x 50.8mm)

6652 2 004-54

4-position
Supports up to (4) Type 85 mounting brackets

1" x 20" x 4"


(25.4mm x 508mm x 101.6mm)

6652 2 004-30

1" x 24" x 4"


(25.4mm x 609.6mm x 101.6mm)

6652 2 004-57

23" wide inverted support bar, 4" legs Quantity: 1


2 required for installation
Supports up to (3) Type 85 or Type 105 mounting brackets

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

225

Copper Cable Management Solutions

19" wide support bar, 4" legs Quantity: 1


2 required for installation

102094AE

TrueNet Structured Cabling

Inverted support bars are designed for equipment cabinets in which terminations
must be flush with the front of the equipment rack.

Copper Cable Management Solutions


Jumper Ring Bars

TrueNet Structured Cabling


102094AE

11/11

Copper Cable Management Solutions

Jumper ring bars are used with support bars to route cross-connect jumper wires and patch cords.

19" wide jumper ring bar,


no legs (wall mount)

23" wide jumper ring bar


no legs (wall mount)

35.5" wide jumper ring bar


no legs (wall mount)

19" wide jumper ring bar


2" legs (rack mount)

23" wide jumper ring bar


2" legs (rack mount)

35.5" wide jumper ring bar


2" legs (rack mount)

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

No legs (wall mount)

4.44" x 20" x 5.18"


(112.8mm x 508mm x 131.6mm)

6652 2 004-00

2" legs (rack mount)

4.44" x 20" x 7.18"


(112.8mm x 508mm x 182.4mm)

6652 2 004-01

No legs (wall mount)

4.44" x 24" x 5.18"


(112.8mm x 609.6mm x 131.6mm)

6652 2 006-09

2" legs (rack mount)

4.44" x 24" x 7.18"


(112.8mm x 508mm x 182.4mm)

6652 2 006-08

No legs (wall mount)

4.44" x 36" x 5.18"


(112.8mm x 914.4mm x 131.6mm)

6652 2 006-00

2" legs (rack mount)

4.44" x 36" x 7.18"


(112.8mm x 914.4mm x 182.4mm)

6652 2 015-00

19" wide jumper ring bar Quantity: 1


4 adjustable jumper rings

23" wide jumper ring bar Quantity: 1


4 adjustable jumper rings

35.5" wide jumper ring bar Quantity: 1


7 adjustable jumper rings

www.te.com/adc

+1-952-938-8080

1-800-366-3891

226

Copper Cable Management Solutions

High-density cable manager

Horizontal cable organizer

High-density cable manager for patch panels

Rear wire management guide

Ring wire manager

Copper Cable Management Solutions

Vertical cable organizer

Ordering information follows on the next page

11/11

102094AE

TrueNet Structured Cabling

Accessories

www.te.com/adc

+1-952-938-8080

1-800-366-3891

227

Copper Cable Management Solutions


Accessories

Ordering Information

TrueNet Structured Cabling

Vertical cable organizer Quantity: 1


Fits standard EIA 19" equipment rack; keeps
patch cords and smaller wire groups organized
within each bay

Catalog Number

3.5" x 20" x 4.75"


(88.9mm x 508mm x 120.65mm)

6653 2 701-02

3.5" x 19" x 4.25"


(88.9mm x 482.6mm x 186.95mm)

6653 2 701-03

1.13" x 19" x 1.13"


(28.7mm x 482.6mm x 28.7mm)

6653 2 703-00

High-density cable manager Quantity: 1


Attaches to standard EIA 19" equipment rack; includes
(2) 12-24 screws for mounting to rack. Manages
terminated cables on rear of high-density patch panels.
0.5" flange provides flat tie point. Smooth surface
prevents snagging and protects against damage

1" x 19" x 4"


(25.4mm x 482.6mm x 101.6mm)

6653 2 703-10

High-density cable manager for patch panels


Quantity: 1
Manages terminated cables on rear of PCB patch panel.
Attaches to Category 6 and Category 5e silk-screened
and fascia patch panels

1.75" x 19" x 4"


(25.4mm x 482.6mm x 101.6mm)

6653 3 585-01

Ring wire manager Quantity: 1


Utilizes 5 wire management rings

1.75" x 19" x 3.75"


(44.45mm x 482.6mm x 91.88mm)

6653 2 700-03

3.5" hinged wall mount bracket


Accepts (2) 1RU or (1) 2RU patch panel

3.5" x 19" x 5"


(88.9mm x 914.4mm x 131.6mm)

6653 2 701-00

7" hinged wall mount bracket


Accepts any 4RU combination of patch panels

7" x 19" x 5"


(177.8mm x 482.6mm x 127mm)

6653 2 701-01

Horizontal cable organizer Quantity: 1


Fits standard EIA 19" equipment rack; keeps larger
wire groups organized between bays
Rear wire management guide Quantity: 1
Attaches to back of standard EIA 19" equipment
rack; allows organization of hidden wires and cables.
Recommended for use with Plug n Play patch panels
only. One required for every 24-port group

Hinged wall mount bracket Quantity: 1


Allows easy access to cable side of patch panel for
circuit tracing or wiring re-termination. For left or right
swing opening; simple push-pull latch keeps the panel
secure in closed position

102094AE

Dimensions (HxWxD)

11/11

Copper Cable Management Solutions

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

228

Accessories .................................................................... 230

Copper Connectivity Solutions Accessories and Labels

Labeling ......................................................................... 231

11/11

102094AE

TrueNet Structured Cabling

Copper Connectivity Solutions


Accessories and Labels

www.te.com/adc

+1-952-938-8080

1-800-366-3891

229

Copper Connectivity Solutions


Accessories and Labels

TrueNet Structured Cabling


102094AE

11/11

Copper Connectivity Solutions Accessories and Labels

Accessories

HighBand dummy plug HighBand marking cap

HighBand to Series 2
adapter

HighBand look-bothways test cord

HighBand winged
test adapter

HighBand bridging
test cord

HighBand disconnect
plug

Ordering Information
Description

Quantity

Catalog Number

6451 2 178-04

Red dummy plug


Plastic plug inserts into test/patch port of Ultim8 or HighBand
10 blocks for quick identification of special circuits. Flat surface
can be written on or accepts a small adhesive sticker. Plugs block
access to the pair and prevent accidental removal of jumper wires

100

6451 5 035-00

Red marking cap


Plastic cap snaps over an Ultim8 or HighBand 10 block pair
for quick identification of special circuits. Caps block access to
prevent accidental removal of jumper wires, but do not interfere
with patching

20

6462 2 101-01

Disconnect plug
Plastic plugs insert into the patch/test port of Ultim8
or HighBand 10 blocks to open (disconnect) a circuit

20

HighBand 10 to Series 2 adapter


1-pair adapter accepts any single pair Series 2 test cord for
HighBand 10 testing

White
Green

6462 2 097-00
6462 2 097-20

Bridging test cord


1-pair connector to two banana plugs (connect to test
equipment); used to test parallel to the circuit

6648 2 900-XX*

Look-both-ways test cord


1-pair connector to four banana plugs; provides ability
to isolate cable side from jumper side

6648 2 901-XX*

Winged test adapter


Provides ability to monitor a circuit without disruption

6646 3 001-01

Ultim8/Highband 10 1-pair site mounted test cord


Monitor or look-both-ways test circuit with flip of a switch.
Mounts on 1 position of back mount frame or directly on a
wall. Includes RJ11 jack to quickly isolate feeder or distribution
network problems

6645 2 127-XX*

*Replace XX with:
www.te.com/adc

01 = 1'
04 = 4'

07 = 7'
10 = 10'
+1-952-938-8080

1-800-366-3891

230

Copper Connectivity Solutions


Accessories and Labels

Recommended for patched environments, this


transparent label strip snaps onto the face of an
Ultim8 or HighBand 10 block. The label strip
covers only the top row of the block and is fully
visible with patch cords in place. Includes slide-in
paper labels (Catalog Number: 6631 3 102-XX)
or can be written on directly.

Type 105 label strip shown on HighBand 10 block

Ordering Information
Dimensions (HxWxD)

Type 105 label strip Quantity per Pack: 10

0.81" x 4.25" x 0.88"


(20.6mm x 107.9mm x 22.2mm)

11/11

Catalog Number
6462 2 096-00

Type 105 Label Holder


The label holder mounts on a universal mounting
system mounting bracket in the Type 105
position, a Type 105 mounting bracket or a Type
105 rod mount bracket to provide extensive
labeling. Jumper rings on both sides provide
additional wire management. Each label holder
requires one block position. A paper label and
plastic cover are included. Accepts label Catalog
Number: 6631 3 106-XX.
Type 105 label holder

Ordering Information
Description

Dimensions (HxWxD)

Type 105 label holder Quantity: 1

www.te.com/adc

0.81" x 5.63" x 1.31"


(20.57mm x 143mm x 33.27mm)

+1-952-938-8080

Catalog Number
6630 2 004-05

1-800-366-3891

231

Copper Connectivity Solutions Accessories and Labels

Description

102094AE

TrueNet Structured Cabling

Type 105 Label Strip

Copper Connectivity Solutions


Accessories and Labels

TrueNet Structured Cabling


102094AE

Recommended for jumpered environments, the holder snaps onto a block face to provide a hinged
cover over the block termination contacts and patch/test ports. A clear plastic protective cover and a
paper label (Catalog Number: 6631 3 100-03) are included for each side of the hinged cover.
The hinged label holder extends 0.38 inches (9.5mm) from the face of the block.

Hinged label holder (closed)

Hinged label holder (open)

Ordering Information
Description

Dimensions (HxWxD)

Type 105 hinged label holder Quantity: 1

0.63" x 4.31" x 0.63"


(16mm x 109.5mm x 16mm)

Catalog Number
6089 2 015-01

Side-Mount Label Holder


The holder mounts onto the side of any Ultim8
or HighBand 10 block. Two side-mount label
holders attach to each block, one on each side.
A small rectangular paper label is included with
each holder.

Side-mount label holder

11/11

Copper Connectivity Solutions Accessories and Labels

Type 105 Hinged Label Holder

Ordering Information
Description

Dimensions (HxWxD)

Side-mount label holder Quantity: 1

www.te.com/adc

0.63" x 1" x 0.31"


(16mm x 25.4mm x 7.87mm)

+1-952-938-8080

Catalog Number
6462 2 016-00

1-800-366-3891

232

Copper Connectivity Solutions


Accessories and Labels

Label Sheet for


Type 105 Hinged

Label Sheet for Type


105 Label Holder

Label Sheet for Type


105 Label Strip

Color

Identifies

Orange

Demarcation point (e.g., central office terminations)

Green

Network connections (e.g., network and auxiliary equipment)

Purple

Common equipment, PBX, LANs, multiplexers (e.g., switching and data equipment)

White

First level backbone (e.g., main cross-connect [MC (campus distributer[CD])]


to a horizontal cross-connect [HC (floor distributer [FD])] or to an intermediate
cross-connect [IC (building distributer [BD])])

Gray

Second level backbone (e.g., IC [BD] to a HC [FD])

Blue

Horizontal cable (e.g., horizontal connections to telecommunications outlets; formerly


referred to as station cable)

Brown

Interbuilding backbone (campus cable terminations)


NOTE: Brown takes precedence over white or gray for interbuilding runs

Yellow

Miscellaneous (e.g., auxiliary, alarms, security)

Red

Reserved for future use (also, key telephone systems)

Based on ANSI/TIA/EIA-606-A, May 1, 2002

11/11

Ordering information follows on the next page

Tech Tip
Use of the TIA/EIA-606 color standards greatly increases identification of network system components.
TE strongly recommends following standards whenever possible.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

233

Copper Connectivity Solutions Accessories and Labels

Examples of TIA/EIA-606 Color Coding

102094AE

TrueNet Structured Cabling

Paper Labels

Copper Connectivity Solutions


Accessories and Labels
Paper Labels
Ordering Information

6631 3 100-03

Paper label sheets in TIA/EIA-606 colors for Type 105 hinged label holder
Quantity: 1 sheet per package
Labels come pre-cut on an 8.5" x 11" sheet with
50 labels per sheet; accommodate hand or laser printing

6631 3 105-XX*
Not available in
-05 (brown),
-06 (yellow),
-07 (red) or
-08 (white)

Paper label sheet for Type 105 label holder


Quantity: 1 sheet per package
Labels come pre-cut on an 8.5" x 11" sheet, with 26 labels per sheet

6631 3 106-XX*

Paper label sheet for Type 105 label strip


Quantity: 1 sheet per package
Labels come perforated on an 8.5" x 11" sheet, 20 labels per sheet;
accommodate hand or laser printing. Available in all TIA/EIA-606 specified colors,
two colors per sheet (one color on each side)
Orange, red

6631 3 102-01/09

Green, purple

6631 3 102-02/03

White, blue

6631 3 102-04/06

Gray, brown

6631 3 102-05/07

Yellow, white

6631 3 102-08

*Replace XX with:

00
01
02
03
04

=
=
=
=
=

orange
green
purple
gray
blue

05
06
07
08

=
=
=
=

brown
yellow
red
white

102094AE

TrueNet Structured Cabling

Catalog Number

Paper label sheet for Type 105 hinged label holder


Quantity: 1 sheet per package
Labels come pre-cut on a white, 8.5" x 11" sheet, with 50 labels per sheet;
accommodate hand or laser printing

11/11

Copper Connectivity Solutions Accessories and Labels

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

234

Copper Connectivity Solutions


Accessories and Labels

TE offers a complete labeling solution by


SharpMark for TEs most popular copper and fiber
solutions. TE labels are design to be used with a
PC and standard laser printer. All label sheets are
available through an TE authorized distribution
partner. Contact TE Customer Service at 1-800366-3891 for more details.

TE's Free Labeling Software

Features
Easy to download software can be used with
Windows or Vista
Label sheets are designed specifically for TEs
most popular products

Copper Connectivity Solutions Accessories and Labels

The free labeling software can be down loaded


from TEs website at www.TE.com/truenet/labels
in less than 5 minutes. The labeling software
is also available to TEs PACE (Professional
Architects, Consultants and Engineers) members
on their dedicated portal. If you are not a
member of the PACE program or would like more
details, you can register at
www.adc.com/partners.

11/11

102094AE

TrueNet Structured Cabling

Copper and Fiber Labeling Software and Labeling Sheets

www.te.com/adc

+1-952-938-8080

1-800-366-3891

235

Copper Connectivity Solutions


Accessories and Labels
Copper and Fiber Labeling Software and Labeling Sheets
Ordering Information

TrueNet Structured Cabling


102094AE

Products that use


the label

Catalog Number

Adhesive label sheet for TE's C5e and C6 silk screen


patch panels. Each label sheet contains 125 individual labels.

SH

6653 1 677-24
6653 1 677-48
6653 1 585-24
6653 1 585-48

ADCLS-SSA

Paper label sheet for TE's C5e and C6 fascia patch panels.
Each label sheet contains 90 individual labels.

SH

6653 1 679-24
6653 1 679-48
6653 1 587-24
6653 1 587-48

ADCLS-FSC

Paper label sheet for TE's C5e and C6 Dynamic


left/right angle patch panels. Each label sheet contains
42 individual labels.

SH

PP24AC6T
PP48C6T
PP24AC5ET
PP48C5ET

ADCLS-DAA

Paper label sheet for TE faceplate and surface box


station windows. Each label sheet contains 100
individual labels.

SH

6653 1 607-00
6653 1 608-00

ADCLS-FPC

Adhesive label sheet for TE's 12-Port 89D Style patch panels.
Each label sheet contains 100 individual labels.

SH

6653 2 705-12

ADCLS-PPA

Paper label for TE's C6 HighBand 25 and CopperTen 20-Pair


terminiation blocks. Each label sheet contains
18 individual labels.

SH

6462 2 408-00

ADCLS-HB25C

Paper label for TE's C6 Ultim8 and CopperTen 8-Pair


terminiation blocks label strip. Each label sheet contains
55 individual labels.

SH

6462 2 096-00

ADCLS-LSC

Paper label for TE's FT terminiation blocks label holder. Each


label sheet contains 30 individual labels.

SH

6631 2 003-00

ADCLS-FTC

Paper label for TE's C6 Ultim8 and CopperTen 8-Pair


terminiation blocks hindge label holder. Each label sheet
contains 22 individual labels.

SH

6089 2 015-01

ADCLS-HNGC

Paper label for TE's CopperTen patch panels.


Each label sheet contains 300 individual labels.

SH

TPNP-24APC10-BK
TPNP-24APC10-UN
TPNP-NNC10U-NN
TPNP-24NC10-BK

ADCLS-CTAPC

Adhesive label for TE's CopperTen Angled patch


panel center label strip. Each label sheet contains
12 individual labels.

SH

TPNP-24APC10-BK
TPNP-24APC10-UN

ADCLS-CTAPA

1-800-366-3891

UOM

11/11

Copper Connectivity Solutions Accessories and Labels

Description

www.te.com/adc

+1-952-938-8080

236

Copper Connectivity Solutions


Accessories and Labels
Copper and Fiber Labeling Software and Labeling Sheets
Ordering Information
Catalog Number

Adhesive label for TE's patch cords or horizontal cable 1/2" x 1 1/2'.
Each label sheet contains 105 individual labels.

SH

ADCLS-CL4A

Adhesive label for TE's patch cords or horizontal cable 1" x 1 1/2'.
Each label sheet contains 49 individual labels.

SH

ADCLS-CL10A

Adhesive label for TE's patch cords or horizontal cable 1" x 2 1/4".
Each label sheet contains 35 individual labels.

SH

ADCLS-CL12A

Adhesive label for TE's patch cords or horizontal cable 1" x 5 1/2".
Each label sheet contains 14 individual labels.

SH

ADCLS-CL24A

Adhesive label for TE's 192 Fiber NGF Blocks.


Each label sheet contains 1 label sheet for left side of block.

SH

ADCLS-NGF192LCAL

Adhesive label for TE's 192 Fiber NGF Blocks.


Each label sheet contains 1 label sheet for right side of block.

SH

ADCLS-NGF192LCAR

Adhesive label for TE's 144 Fiber NGF Blocks.


Each label sheet contains 1 label sheet for left side of block.

SH

ADCLS-NGF144SCAL

Adhesive label for TE's 144 Fiber NGF Blocks.


Each label sheet contains 1 label sheet for right side of block.

SH

ADCLS-NGF144LCAR

Adhesive label for TE's 1RU TFP Fiber Panel.


Each label sheet contains 16 labels for the front and back of the hinged label.

SH

ADCLS-TFP1RUA

Adhesive label for TE's 2RU TFP Fiber Panel.


Each label sheet contains 6 labels for the front and back of the hinged label.

SH

ADCLS-TFP2RUA

Adhesive label for TE's 5RU TFP Fiber Panel.


Each label sheet contains 2 labels for the front and back of the hinged label.

SH

ADCLS-TFP5RUA

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

237

Copper Connectivity Solutions Accessories and Labels

UOM

102094AE

TrueNet Structured Cabling

Description

Work Area Solutions

Introduction ................................................................... 240


Category 6a Modular Jacks ............................................ 241
Category 6 Modular Jacks ............................................. 242
Category 5e Modular Jacks ............................................ 243
Modular Adapters .......................................................... 244
Angled Port Faceplates .................................................. 246
Flush Mount Faceplates ................................................. 247
Specialty Faceplates ....................................................... 249
Decorative Faceplates .................................................... 250
Modular Furniture Faceplates ......................................... 251
Surface Mount Boxes ..................................................... 253
Surface Box for Modular Furniture ................................. 254

102094AE

TrueNet Structured Cabling

Work Area Solutions

Specialty Boxes .............................................................. 255

11/11

Accessories .................................................................... 258

www.te.com/adc

+1-952-938-8080

1-800-366-3891

239

Work Area Solutions

TrueNet Structured Cabling

102094AE

Features

11/11

Work Area Solutions

Introduction

Field-configurable station outlets available in flush mount, surface mount and furniture mount styles
One-, two-, three-, four- or six-ports in a single-gang faceplate or four-, eight-, twelve-port
dual-gang faceplates allow custom configurations utilizing a wide range of individual RJ11
or RJ45 jacks, F-81, RCA, S-Video, ST, SC, MTRJ, LC or BNC connectors
Voice and data ID tabs come color-matched with each faceplate
Top and bottom labels allow discrete station identification
RJ45 jacks are available to support TrueNet Category 5e, Category 6 and CopperTen structured
cabling systems
A complete range of modular jacks and connector modules can be used interchangeably
in all outlets, surface boxes and Plug-n-Play patch panels
Two-, three-, and four-port modular furniture faceplates can be used in office systems produced by
companies such as Haworth, Steelcase, Herman Miller, Kimball, Knoll, Teknion and AllSteel

www.te.com/adc

+1-952-938-8080

1-800-366-3891

240

Work Area Solutions


Category 6a Modular Jacks

11/11

102094AE

Work Area Solutions

TrueNet Structured Cabling

CopperTen Modular Jacks


An integral part of TE's TrueNet Structured
Cabling System, CopperTen is the world's
first UTP structured cabling system to enable
10 Gigabit Ethernet over a full 100 meters.
Installed in high-performance networks
worldwide, the system's patent-pending design
minimizes alien crosstalk and insertion loss and
meets the performance requirements of IEEE
802.3an and TIA/EIA 568-B.2-10 standards.
The CopperTen modular jack features LSA-PLUS
silver-plated 45-degree angled contacts for the
most secure and reliable connection available.

Features
Meets or exceeds performance requirements
of TIA/EIA 568-B.2-10 standards
45-degree silver-plated IDCs provide secure,
reliable gas-tight connections
Accepts LSA-Plus Insertion or 110 tool
for wire termination
Universal A/B wiring label
Modular jacks fit port openings of
0.585" x 0.757" (14.86 mm x 19.23 mm)
with plate thickness from 0.048" to 0.060"
(1.23 mm x 1.52 mm)

Ordering Information
Description

Catalog Number*

CopperTen RJ45 UTP modular 568A/B jack


Quantity: 1

6830 1 835-XX

*Replace XX with:
01 = White
06
02 = Ivory
07
03 = Gray
08
04 = Black
09
05 = Red
10
22 = Electrical Ivory

www.te.com/adc

=
=
=
=
=

Blue
Green
Yellow
Purple
Orange

+1-952-938-8080

1-800-366-3891

241

Work Area Solutions


Category 6 Modular Jacks
KM8 Modular Jacks

TrueNet Structured Cabling


102094AE

11/11

Work Area Solutions

KM8 modular jacks are an integral part of the


TrueNet channel solution. Tuned together with
other TrueNet Category 6 components and cable,
KM8 jacks help deliver zero bit error network
performance.
A KM8 modular jack with cable management
system ensures reliable field termination. The
cable manager holds cable pairs in place up to
the termination point, preventing cable untwist
and buckle, guaranteeing dependable and
repeatable performance.
These modular jacks can be used in TEs modular
patch panels.
KM8 modular jack

Features
TrueNet impedance matched jacks
guarantee maximum throughput
Meets or exceeds TIA/EIA Category 6
requirements
45-degree silver-plated IDCs provide secure,
reliable gas-tight connections
Compatible with any TrueNet modular faceplate, modular furniture faceplate, surface
box and modular patch panel
Accepts either a LSA-Plus Insertion or 110
tool for wire termination for punchdown jack
Universal A/B wiring label

Ordering Information
Description

Catalog Number

KM8 RJ45 modular punchdown jack Quantity: 1

6830 1 830-XX

*Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black
05 = Red
06 = Blue

www.te.com/adc

07
08
09
10
22

=
=
=
=
=

Green
Yellow
Purple
Orange
Electrical ivory

+1-952-938-8080

1-800-366-3891

242

Work Area Solutions


Category 5e Modular Jacks

Work Area Solutions

K610 series jacks are an integral part of the


TrueNet channel solution. Tuned together with
other TrueNet Category 5e components and
cable, K610 jacks help deliver zero bit error
network performance.
The K610 series jacks can be used in TEs
modular patch panels.

Features
K610 Series jack

Available in right angle style


Compatible with any TrueNet modular
faceplate, modular furniture faceplate,
surface box and modular patch panel
Available in eleven colors for easy port
identification
Accept either LSA-Plus Insertion or 110 tool
for termination

Color

RJ45 T568A/B
Right Angle
6467 5 181-20
6467 5 181-10
6467 5 181-00
6467 5 181-30
6467 5 181-50
6467 5 181-40
6467 5 181-80
6467 5 181-90
6467 5 181-70
6467 5 181-60
6467 5 181-22

White
Ivory
Gray
Black
Red
Blue
Green
Yellow
Purple
Orange
Electrical Ivory

RJ45 USOC
Right Angle
6467 5 198-20
6467 5 198-10
6467 5 198-00
6467 5 198-30
6467 5 198-50
6467 5 198-40
6467 5 198-80
6467 5 198-90
6467 5 198-70
6467 5 198-60
6467 5 198-22

RJ11 USOC
Right Angle
6467 5 195-20
6467 5 195-10
6467 5 195-00
6467 5 195-30
6467 5 195-50
6467 5 195-40
6467 5 195-80
6467 5 195-90
6467 5 195-70
6467 5 195-60
6467 5 195-22

11/11

102094AE

TrueNet Structured Cabling

K610 Series Jacks

www.te.com/adc

+1-952-938-8080

1-800-366-3891

243

Work Area Solutions


Modular Adapters

SC adapter

BNC adapter

Blank insert

ST adapter

Ordering information follows on the next page

102094AE

TrueNet Structured Cabling

F-81 adapter

11/11

Work Area Solutions

Compatible with TEs modular faceplates, surface mount boxes, modular furniture faceplates and
modular patch panels, these adapters offer the versatility of a Plug-n-Play system.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

244

Work Area Solutions


Modular Adapters

Description

Catalog Number*
6645 1 157-XX

SC multimode/singlemode adapter Quantity: 1


Used with faceplate extender in flush mount faceplates
Metal adapter sleeve

6645 1 167-XX

Ceramic adapter sleeve

6645 1 169-XX

ST multimode/singlemode adapter Quantity: 1


Straight tip style
Phosphor bronze adapter sleeve

6645 1 158-XX

Ceramic adapter sleeve

6645 1 166-XX

LC multimode/singlemode adapter Quantity: 1


Multimode, phosphor bronze adapter sleeve

6645 1 172-XX

Singlemode, UPC ceramic sleeve

6645 1 173-XX

Singlemode, APC ceramic sleeve

6645 1 174-XX

BNC adapter Quantity: 1

6645 1 159-XX

Blank modular Insert Quantity: 25


Cover unused ports; compatible with any TE modular faceplate, surface mount
box, modular furniture plates, patch panels
White

6645 1 160-01

Ivory

6645 1 160-02

Gray

6645 1 160-03

Black

6645 1 160-04

*Replace XX with:
01 = White
02 = Ivory

11/11

102094AE

TrueNet Structured Cabling

F-81 adapter Quantity: 1


Standard 75 ohm connector

www.te.com/adc

+1-952-938-8080

1-800-366-3891

245

Work Area Solutions

Ordering Information

Work Area Solutions

102094AE

TrueNet Structured Cabling

These faceplates accept any combination of modular jacks and


connectors found in this section. All faceplates and surface
mount boxes are constructed of durable ABS plastic that meets
UL 1863 safety rating and UL 94V-0.

11/11

Work Area Solutions

Angled Port Faceplates

Extender

8-port angled faceplate

4-port angled faceplate

Ordering Information
Description

Dimensions (HxWxD)

4-port angled faceplate Quantity: 1


Fits standard, single-gang box; 2 outlet
labeling areas, 4 individual port ID areas;
includes blank paper labels, clear plastic
label protectors, logo insert, reversible-icon
ID tabs numbered 16 (icon colors match
faceplate), mounting screws (#6-32 x 15/16")

4.5" x 2.75" x 0.25"


(114.5 mm x 70.0 mm x 6.35 mm)

Catalog Number*
6644 1 174-XX

8-port angled faceplate Quantity: 1


4.5" x 4.94" x 0.25"
Requires standard NEMA double-gang
(114.5 mm x 125.48 mm x 6.35 mm)
opening of at least 3.563" x 2.75" (some
surface mount boxes do not meet this
specification; please check carefully); 4
outlet labeling areas and 8 individual port ID
areas; includes blank paper labels, clear
plastic label protectors, logo inserts, 2 sets
of reversible-icon ID tables numbered 16
(icon colors match faceplate), mounting
screws (#6-32 x 15/16"). Not compatible
with dual-gang mud rings

6644 1 178-XX

Faceplate extender Quantity: 1


Provides room to allow for fiber bend radius,
storage spool or additional copper cable
working space; mounts on front of any
standard single-gang NEMA box or All-Fit
surface mount box to extend depth 1-inch;
includes 2 mounting screws (#6-32 x 2").
Recommended for use with simplex SC
adapters

6644 2 018-XX

4.75" x 3.13" x 1"


(120.1 mm x 79. 5mm x 25.4 mm)

*Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black
22 = Electrical ivory

www.te.com/adc

+1-952-938-8080

1-800-366-3891

246

Work Area Solutions

The faceplates accept any combination of modular jacks and connectors listed in this section. The
variety of reversible-icon and color ID tabs for labeling provides a versatile and highly visible information
outlet system.

4-port faceplate

2-port faceplate

4-port, dual-gang faceplate

6-port faceplate

8-port, dual-gang faceplate

12-port, dual-gang faceplate

11/11

102094AE

TrueNet Structured Cabling

These faceplates provide the basis for a wide range of possible information outlet combinations. With a
single-gang capacity up to six ports, and a double-gang capacity of 12 ports, TE can provide the density
for the most demanding installation.

CopperTen 4-port
staggered faceplate

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

247

Work Area Solutions

Flush Mount Faceplates

Work Area Solutions


Flush Mount Faceplates

Description

Dimensions (HxWxD)

TrueNet Structured Cabling

Single-gang flush mount faceplates


Quantity: 1
Fit standard single-gang boxes. Include
2 blank paper labels, 2 clear plastic label
protectors, 1 logo insert, 6 reversible-icon
ID tabs numbered 16 (icon colors
match faceplate), 2 mounting screws
(#6-32 x 15/16")

102094AE

Catalog Number 1

4.5" x 2.75" x 0.25"


(114.5 mm x 70.0 mm x 6.35 mm)

2-port faceplate
2 outlet labeling areas and 2 individual
port ID areas

6644 1 152-XX

4-port faceplate
2 outlet labeling areas and 4 individual
port ID areas

6644 1 154-XX

CopperTen 4-port staggered faceplate


Includes: 2 outlet labeling areas and 4
individual port ID areas.

TNSCSFPSO4-YY 2

6-port faceplate
2 outlet labeling areas and 6 individual
port ID areas

6644 1 156-XX

Dual-gang flush mount faceplates


Quantity: 1
Require a standard NEMA double-gang
opening of at least 3.563" x 2.75"
(some surface mount boxes do not meet
this specification; please check carefully).

11/11

Work Area Solutions

Ordering Information

4.5" x 4.94" x 0.25"


(114.5 mm x 125.48 mm x 6.35 mm)

4-port faceplate
4 outlet labeling areas and 8 individual
port ID labels. Include blank paper labels,
clear plastic label protectors, logo inserts,
2 sets of reversible-icon ID tabs numbered
16 (icon colors match faceplate),
4 mounting screws (#6-32 x 15/16")

6644 1 164-XX

8-port faceplate
4 outlet labeling areas and 8 individual
port ID labels. Include blank paper labels,
clear plastic label protectors, logo inserts,
2 sets of reversible-icon ID tabs numbered
16 (icon colors match faceplate),
4 mounting screws (#6-32 x 15/16")

6644 1 168-XX

12-port faceplate
4 outlet labeling areas and 12 individual
ports numbered consecutively, left to right,
top to bottom. Includes 4 blank paper
labels, 4 clear plastic label protectors,
2 logo inserts, 4 mounting screws
(#6-32 x 15/16")

6644 1 157-XX

Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black
22 = Electrical Ivory

www.te.com/adc

Replace YY with:
BK = Black
IV = Ivory

+1-952-938-8080

GY = Gray
WT = White

1-800-366-3891

248

Work Area Solutions

4-port Walker
Monument faceplate

Drywall faceplate adapter shown


with flush mount faceplate

Dual-gang surface mount box

2-port electrical faceplate

4-port electrical faceplate

Ordering information follows on the next page

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

249

Work Area Solutions

Stainless steel wall phone plate

102094AE

TrueNet Structured Cabling

Specialty Faceplates

Work Area Solutions


Specialty Faceplates

TrueNet Structured Cabling


102094AE

11/11

Work Area Solutions

Ordering Information
Description
Stainless steel faceplate Quantity: 1
Standard single-gang faceplate accepts any
combination of modular jacks (which mount
flush with the surface of the faceplate) and
adapters found in this section. Not for use
with shielded jacks. Includes
2 mounting screws (#6-32 x 15/16")

Dimensions (HxWxD)
4.5" x 2.75" x 0.25"
(114.5 mm x 70.0 mm x 6.35 mm)

Catalog Number

1-port

6644 1 024-01

2-port

6644 1 024-02

3-port

6644 1 024-03

4-port

6644 1 024-04

6-port

6644 1 024-06

Stainless steel wall phone plate Quantity: 1

4.5" x 2.75" x 0.25"

4-port Walker Monument faceplate


Quantity: 1 Compatible with Walker 500
Series housing; 4-port faceplate accepts any
combination of modular jacks and adapters;
features workstation labeling and individual
port designation ID tabs; includes 6 ID tabs
(same color as faceplate), 1 station ID window
and label, 2 mounting screws

(114.5 mm x 70.0 mm x 6.35 mm)

6644 3 000-53

White

6644 1 165-01

Ivory

6644 1 165-02

Drywall faceplate adapter Quantity: 1


For adding outlet to wall with no backbox;
compatible with all TE single-gang
faceplates; adjustable to fit 0.25" thick to 1"
thick wallboard, paneling or drywall. Can
be mounted horizontally or vertically and
can be used as template for cutout hole;
thin front lip design allows adapter to seat
better on drywall

6644 2 019-00

Electrical faceplate 106 adapters Quantity: 1


3.13" x 1.61" x 0.38"
Match electrical faceplate knockouts and
(79.5 mm x 40.89 mm x 9.65 mm)
come in choice of standard electrical colors;
include 6 reversible-icon ID tabs numbered
16 (icon colors match adapter), 2
mounting screws (#6-32 x 15/16")
2-port
Allows mounting of 2 modular jacks or
connectors in a standard electrical-style
outlet box; 2 individual port ID areas

6644 1 106-XX*

4-port
Allows mounting of 4 modular jacks or
connectors; recessed numbering, 14, on
front of adapter for easy port identification

6644 1 107-XX*

Dual-gang surface mount box Quantity: 1


Compatible with electrical faceplate 106
adapters and all dual-gang faceplates;
knockouts provide cabling access from all
4 sides and rear in several size. Ivory only
*Replace XX with:

www.te.com/adc

21 = Electrical white
22 = Electrical ivory

4.75" x 5" x 1.75"


(120.1 mm x 127.0 mm x 44.5 mm)

23 = Electrical gray
24 = Electrical brown

+1-952-938-8080

6644 3 000-28

04 = Black

1-800-366-3891

250

Work Area Solutions


Modular Furniture Faceplates

102094AE

Work Area Solutions

TrueNet Structured Cabling

TEs modular furniture faceplates are compatible with leading office furniture and accept TEs modular
jacks and connectors. Contact TE Technical Assistance Center for specific model compatibility.

3-port modular furniture faceplate

4-port modular furniture faceplate

2-port horizontal faceplate

CopperTen
furniture faceplate
faceplate
4-port
modular furniture

Modular Furniture Faceplate Compatibility


3-port

4-port

Steelcase 9000

Herman Miller, Action Office 1

Steelcase Avenir

Herman Miller, Action Office 2

Steelcase Context

Herman Miller, Action Office 3

AllSteel 8000

Herman Miller, Ethospace (baseline)

Knoll Morrison

Herman Miller

Knoll Reff

Phoenix

Haworth Places and Unigroup

Kimball

11/11

Haworth Places
Haworth Premise
Haworth Race

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

251

Work Area Solutions


Modular Furniture Faceplates

102094AE

TrueNet Structured Cabling

Description

11/11

Work Area Solutions

Ordering Information
Dimensions (HxWxD)

Catalog Number*

CopperTen 3-port modular


furniture faceplate
Quantity: 1
Recommended opening: 1.38" x 2.71"
(35.05 mm x 68.83 mm)
3 individual port ID areas; includes 6
reversible-icon ID tabs numbered 16
(icon colors match faceplate)

2.15" x 3.12" x 1.06"


(54.61 mm x 79.25 mm x 26.92 mm)"

TNSCSFPFS03-XX

3-port modular furniture faceplate


Quantity: 1
Recommended opening: 2.65" x 1.377"
(67.31 mm x 34.98 mm)
Maximum thickness: 0.06" (1.52 mm)
3 individual port ID areas; includes 6
reversible-icon ID tabs numbered 16
(icon colors match faceplate)

1.61" x 3.13" x 0.38"


(40.9 mm x 79.5 mm x 9.65 mm)

6644 1 143-XX

4-port modular furniture faceplate


Quantity: 1
Fits openings 1.890" to 1.920"
(48 mm to 48.77 mm) high, 2.572" to 3.866"
(65.33 mm to 98.2 mm) wide
Maximum thickness: 0.08" (2.03 mm)
1 outlet labeling area, 4 individual port ID
areas; includes 2 blank paper labels, 1 clear
plastic label protector, 1 logo insert,
6 reversible-icon ID tabs numbered 16
(icon colors match faceplate)

2.17" x 3.9" x 0.38"


(55.12 mm x 99 mm x 9.65 mm)

6644 1 144-XX

4-port Beltline adapter for Herman


Miller Ethospace furniture Quantity: 1
2-port horizontal faceplate
Quantity: 1
Fits standard NEMA openings in modular
furniture raceways or standard single-gang
boxes; designed for horizontal orientation;
1 outlet labeling area, 2 individual port ID
areas; ID tabs hide faceplate mounting
screws. Includes 2 blank paper labels, 1 clear
plastic label protector, 6 reversible-icon ID
tabs numbered 16 (icon colors match
faceplate), 2 mounting screws (#6-32 x
15/16", with custom head)

6644 3 299-XX
2.75" x 4.5" x 0.25"
(69.85 mm x 114.3 mm x 6.35 mm)

6644 1 112-XX

*Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black

www.te.com/adc

+1-952-938-8080

1-800-366-3891

252

Work Area Solutions

4-port surface
mount box

CopperTen 6-port
surface mount box

Ordering Information
Description

Dimensions (HxWxD)

102094AE

2-port surface mount box Quantity: 1


1 outlet labeling area, 2 individual port ID
areas; includes 1 blank paper label, 1 clear
plastic label protector, 1 logo insert, 6
reversible icon ID tabs numbered 16
(icon colors match faceplate), hook-and-loop
fastener strips. Knockouts allow cable and
raceway access

11/11

2-port surface
mount box

6-port surface
mount box

Catalog Number 1

1" x 2.25" x 2.31"


(25.4 mm x 57.2 mm x 58.67 mm)

6644 1 222-XX

4-port surface mount box Quantity: 1


1 outlet labeling area, 4 individual port ID
areas; includes 1 blank paper label, 1 clear
plastic label protector, 6 reversible icon
ID tabs numbered 16, 1 screw for
locking down cover and hook-and-loop
fastener strips. Knockouts allow cable and
raceway access

2.88" x 4.25" x 1"


(73.15 mm x 107.95 mm x 25.4 mm)

6644 1 224-XX

6-port surface mount box Quantity: 1


2 outlet labeling areas, 6 individual port ID
areas; includes 1 blank paper label, 1 clear
plastic label protector, 6 reversible icon ID
tabs numbered 16 (icon colors match
faceplate), 2 mounting screws (#6-32 x
15/16"), hook-and-loop fastener strips.
Knockouts allow cable access from 3 sides

3.38" x 6" x 1.5"


(85.85 mm x 152.4 mm x 38.1 mm)

6644 2 201-XX

CopperTen 6-port surface mount box


7.00" x 5.00" x 1.375"
Quantity: 1 Individual port ID areas; includes (85.85 mm x 152.4 mm x 38.1 mm)
2 blank paper labels, 2 clear plastic label
protectors, 6 reversible icon ID tabs numbered
16 (icon colors match faceplate), 2 mounting
screws (#6-32 x 15/16"), hook-and-loop
fastener strips. Knockouts allow cable
access from 3 sides

TNSCSSB6-YY 2

Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black
22 = Electrical Ivory

Replace YY with:
BK = Black
IV = Ivory

Right angle jacks


are recommended
for surface boxes

GY = Gray
WT = White
Surface box installation

www.te.com/adc

+1-952-938-8080

6-port
surface box

1-800-366-3891

253

Work Area Solutions

TrueNet Structured Cabling

Surface Mount Boxes

Work Area Solutions

Features
Six-port cable guides for cable management
Discrete port labeling
Flush face for clean look and protection
of connectors
Constructed of durable ABS plastic,
rated UL 94V-0
UL1863 safety rating

Ordering Information
Description

Dimensions (HxWxD)

12-port surface box

Catalog Number

1.61" x 3.13" x 0.38"


(40.9 mm x 79.5 mm x 9.65 mm)

6644 1 460-01

6.7" x 5.1" x 1.45"

6630 3 025-01

0.06" x 3" x 5.75"


(1.52 mm x 76.2 mm x 146.05 mm)

6630 3 025-09

Surface box mounting accessories


Double sticky-back tape Quantity: 1
Used to mount surface boxes permanently
to smooth surfaces
Magnet strip Quantity: 1
Adhesive backed, magnetic strip

102094AE

TrueNet Structured Cabling

The surface box for modular furniture accepts


any combination of modular jacks and adapters.
It supports both 6- and 12-port configurations
and is used in zone cabling applications.

11/11

Work Area Solutions

Surface Box for Modular Furniture

www.te.com/adc

+1-952-938-8080

1-800-366-3891

254

Work Area Solutions


Specialty Boxes

11/11

102094AE

TrueNet Structured Cabling

The low-profile, surface mount multimedia box allows installation of fiber, copper and/or coax in a
single unit. It maintains minimum bend radius and fiber storage to comply with TIA/EIA-568-A
ANSI/EIA/TIA-568-B requirements.
A unique hidden labeling system provides identification for sixteen individual ports with colored ID tabs,
paper labels and write-on surfaces on or under a removable door. Angled bezels meet minimum bend
radius requirements and allow the box to be configured to meet the requirements of a specific application.
Raceway entry
from three sides

Rear cable
access

Storage capacity
meets TIA/EIA
requirements

Meets
minimum
bend radius

Convenient
cable tie
anchor points

Grounding
post

Multimedia box shown with selected bezels,


jacks, connectors and ID tabs installed

Ordering Information
Description

Dimensions (HxWxD)

Multimedia box Quantity: 1


Includes logo insert, 1 clear plastic window,
16 reversible icon ID tabs numbered 16,
3 blank bezels, tie wraps, hook-and-loop
fastener

8.25" x 8.25" x 2.25"


(210 mm x 210 mm x 57.15 mm)

Catalog Number*
6644 1 450-XX

Empty multimedia bezels Quantity: 1


Fit in 1 position of multimedia box.
Compatible jacks or adapters ordered
separately
4-port bezel
Accepts up to 4 of any modular jack
or adapter

6644 3 205-XX

6-position SC bezel
Accepts up to 6 SC-style fiber optic
adapters

6644 3 267-XX

Duplex SC/RJ bezel


Accepts 1 duplex 2-port SC bezel
and any 2 modular jacks or adapters

6644 3 211-XX

Blank bezel
Protects opening from dust or other
contaminant's

6644 3 209-XX

Mounting magnets Quantity: 2


Mount the multimedia box on smooth, flat,
metal surfaces

6630 3 025-11

*Replace XX with: 01 = White

www.te.com/adc

02 = Ivory

+1-952-938-8080

1-800-366-3891

255

Work Area Solutions

Multimedia Box

Work Area Solutions


Specialty Boxes

TrueNet Structured Cabling

Surface mount box

4-port box

6-port box

Steel cover box

Standard wall box

Modular furniture

Surface mount

102094AE

The All-Fit box mounts in standard NEMA wall boxes, in modular office furniture and on virtually
any surface. The unique on-board termination design allows installers to punch down wires with jacks
already in place. The snap-on cover includes an optional screw-down feature for added security. The
low-profile design and choice of colors provide an attractive receptacle that blends with any office
decor. Knockouts allow easy access for cable and raceways. The All-Fit box provides both station and
individual port identification.

11/11

Work Area Solutions

All-Fit Specialty Box

Duplex SC bezel

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

256

Work Area Solutions


Specialty Boxes

Ordering Information

11/11

102094AE

TrueNet Structured Cabling

Description

Dimensions (HxWxD)

6-port All-Fit box Quantity: 1


Includes 1 blank paper label, 1 clear plastic
label protector, 6 reversible icon ID tabs
numbered 16 (icon colors match box),
2 mounting screws (#6/32 x 15/16"),
4 All-Fit sliders, hook-and-loop fastener
strips. Meets all TIA/EIA requirements for
fiber storage and spooling; 6 individual port
identification and station labeling areas;
secure, cover locking option; low profile
design. Knockouts on 3 sides for raceway
and cable entrance

1" x 6.5" x 5"


(25.4 mm x 165.1 mm x 127 mm)

Catalog Number*
6644 2 202-XX

4-port All-Fit box Quantity: 1


2.88" x 4.25" x 1"
Includes 1 blank paper label, 1 clear plastic
(73.15 mm x 107.95 mm x 25.4 mm)
label protector, 6 reversible icon ID tabs
numbered 16 (icon colors match box),
2 mounting screws (#6-32 x 15/16"), 1 screw
for locking down cover, hook-and-loop
fastener strips. Knockouts allow cable access
from either top or bottom

6644 1 224-XX

Steel cover for All-Fit box Quantity: 1


2.88" x 4.25" x 1"
Durable 22 gauge steel cover; for use in
(73.15 mm x 107.95 mm x 25.4 mm)
any environment where station outlet is
susceptible to physical abuse or tampering;
painted white. Mounts directly to All-Fit box;
cutouts allow individual port ID tabs to
remain visible. Self-tapping, flat head
mounting screw included. Custom covers
available; contact TE

6644 2 016-01

Duplex SC bezel for All-Fit


multimedia box Quantity: 1
Compatible with SC-style duplex adapter.
Occupies space of any 2 adjacent individual
port openings: recessed so face of adapter
is flush with face of box

6644 3 220-XX

All-Fit surface mount box Quantity: 1


Accepts any TE modular single-gang flush
mount faceplates or electrical faceplate 106
adapters. Cable access provided from rear
and from all 4 sides with knockouts in
several sizes

4.81" x 3" x 1.75"


(122.2 mm x 76.2 mm x 44.45 mm)

6644 2 017-XX

Magnet strip Quantity: 1


Adhesive backed, magnetic strip

0.06" x 3" x 5.75"


(1.52 mm x 76.2 mm x 146.05 mm)

6630 3 025-09

*Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black

www.te.com/adc

+1-952-938-8080

1-800-366-3891

257

Work Area Solutions

All-Fit Specialty Box

Work Area Solutions


Accessories

Catalog Number

Termination puck Quantity: 1


Terminates both in-line and right angle jacks; built-in strain relief

6645 1 180-04

ID tabs with icons numbered 16 Quantity: 6


Snap into individual port identification area above jack or connector opening.
Reversible: data icon on one side, voice icon on other; same number appears on
both sides. Each package contains icons numbered 16

6631 2 125-XX*

Paper labels for faceplates Quantity: 1


Adhesive labels come pre-cut on white 8.5" x 11" sheet, 190 labels per sheet.
Accommodate hand or laser printing. Fit in label area on front of modular faceplates

6631 3 100-06

Labeling templates are available in Microsoft Word and Excel formats.


Please contact TE Technical Assistance Center.
*Replace XX with:
01 = White
02 = Ivory
03 = Gray
04 = Black
05 = Red
06 = Blue
07 = Green
08 = Yellow
09 = Purple
10 = Orange

102094AE

TrueNet Structured Cabling

Description

11/11

Work Area Solutions

Ordering Information

www.te.com/adc

+1-952-938-8080

1-800-366-3891

258

Fiber Main Distribution Frame ........................................ 262


Fiber Termination Blocks (FTBs) ...................................... 265
Sliding Adapter Packs .................................................... 272
Data Center Splice Cabinet ............................................ 273
Accessories .................................................................... 274

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

259

Data Center Optical Distribution Frame Solutions

Introduction ................................................................... 260

102094AE

TrueNet Structured Cabling

Data Center Optical Distribution


Frame Solutions

Data Center Optical Distribution


Frame Solutions

TrueNet Structured Cabling

Frames
TE developed its innovative Optical Distribution Frame (ODF) for high-fiber count applications. At 2304
terminations in a single frame, its unique, user-friendly design and superior cable management provide
enterprise customers an optimum solution to handle applications with high fiber counts such
as data centers.
TEs ODF product line is designed to fit a variety of termination, splice, and storage applications. This
frame is designed with an emphasis on superior cable management and ease of use, including features
such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers.
The frame sections are shipped from the factory fully equipped with all cable management hardware
including a built-in jumper storage panel.
Fiber Termination Blocks (FTBs)
Fiber Termination Blocks (FTBs) are available with SC adapters in block configurations of 144-positions,
and with LC adapters in 144- and 192-positions. FTBs utilize sliding adapter packs to gain easy access
to both the front and rear connectors. FTBs can be ordered with adapters only, with factory terminated
IFC stubs, or as Plug-and-Play cassettes (see pages 348-350).
Sliding Adapter Packs
Sliding adapter packs house groups of fiber optic adapters and are mounted in fiber termination
blocks to provide easy access to connectors. Sliding adapter packs are available with SC and LC
adapters. The adapters come in packs of four and six depending on the adapter type and the desired
termination density.
Data Center Splice Cabinet
The Data Center Splice Cabinet is a high-density splice solution. This cabinet allows up to 1,440 splices
within an enclosed area. The cabinet was developed to be the single splice point and often resides in
the entrance room of the data center. This will allow direct routing of the spliced fiber
into the ODF.

102094AE

TIA-942 presents the cross-connect architecture as the best practice for Main Distribution Area (MDA).
Utilizing a centralized cross-connect frame allows maintenance to be performed without disrupting
the cables attached to active equipment. All moves, adds and changes can be performed on the
passive cross-connect frame. The benefits of deploying a cross-connect architecture in the MDA
include: lower operating costs, enhanced reliability, and a reduced risk of downtime due to poor fiber
jumper management.

11/11

Data Center Optical Distribution Frame Solutions

Introduction

www.te.com/adc

+1-952-938-8080

1-800-366-3891

260

Data Center Optical Distribution


Frame Solutions

11/11

102094AE

Features and Benefits


Ample Trough Space
Reduces jumper pile-up and congestion
- Reduces maintenance time due to easy removal and tracing of jumpers
- Minimizes risk of microbends or damage to fiber
Built-in Jumper Storage Panel
Minimizes number of required jumper lengths
Maintains fiber bend radius
Simplifies frame installation
- Saves money by reducing the number of different jumper lengths that have to be kept in inventory
- Minimizes risk of microbends or damage to fiber
Enclosed system ensures easy cable access without fiber cross-over points
Sliding Adapter Packs
Promotes high density
Provides easy access to connectors
- Saves valuable floor space
- Reduces time required for operations and maintenance
Intelligent Cable Routing System
No fiber cross-over points
Multiple vertical troughways
- Reduces maintenance time due to easier removal and tracing of jumpers and minimizes
fiber weaving
Bend Radius Protection at Every Turn
- ODF provides complete bend radius at every turn to ensure network performance and reliability

www.te.com/adc

+1-952-938-8080

1-800-366-3891

261

Data Center Optical Distribution Frame Solutions

TrueNet Structured Cabling

Introduction

Data Center Optical Distribution


Frame Solutions

TrueNet Structured Cabling


102094AE

11/11

Data Center Optical Distribution Frame Solutions

Fiber Main Distribution Frame (FMDF)

The FMDF is the cornerstone of the ODF product line. This innovative frame has six 5-inch horizontal
troughs for a total of 30 inches of horizontal trough space. This abundant trough space minimizes
fiber pile up and congestion leading to easier moves, adds and changes. The frame has twelve Fiber
Termination Block (FTB) mounting positions equally divided between vertical columns on the left and
right sides of the frame as shown in the figure below. The frame is available in 30-inch wide version
and provides additional vertical trough space for the highest termination density applications. The
built-in jumper storage panel will store up to 3.5 meters (12 feet) of jumper slack.

7
(2.14 m)

24
(61 cm)

30
(76.2 cm)

FMDF Frame
NGFB-MDF7A144-30

Isolation Pad shown with FMDF


NGF-ACCISOP30X24

Ordering Information
Dimensions
(HxWxD)

Description
Fiber Main Distribution Frame (FMDF)
Accommodates 12 Fiber Termination Blocks (FTBs)
or 12 Plug-and-Play Cassette Blocks1
Short Bracket 30" Frame
For use with SC 144-position FTBs, or
LC 192-position FTBs,
LC 144- and 192-position Plug-and-Play
Cassette Blocks1
Long Bracket 30" Frame
For use with LC 144-position FTBs

Catalog Number

7' x 30" x 24"


(2.14 m x 76.2 cm x 61 cm)
NGFB-MDF7A144-30

NGFB-MDF7A100-30

Each frame section includes heavy duty floor anchor bolts for concrete floor applications.
1
For Plug-and-Play Cassette ordering information for ODF frame, see pages 348-350.
Note: TE recommends the use of 1.7 mm/ 1.6 mm jumpers when deploying 192-position FTBs.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

262

Data Center Optical Distribution


Frame Solutions
Frame Accessories

7'
(2.14 m)

24"
(61 cm)

12"
(30.5 cm)

Fiber Optic Terminal Storage Panel


NGFB-ACCFOTSB

Isolation Pad shown with FOTSB


NGF-ACCISOPFS12X24

11/11

Ordering Information
Description
Fiber Optic Terminal Jumper Storage Panel
Use with FMDF Frame
Color: Black

Dimensions (HxWxD)

Catalog Number

7' x 12" x 24"


(2.14 m x 30.5 cm x 61 cm)

NGFB-ACCFOTSB

Isolation Pad - Storage Panel


A template for frame installation providing
isolation between the frame and the ground

NGF-ACCISOPFS12X24

Note: When using the Fiber Optic Terminal Storage Panels, a cable exit UP block must be used.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

263

Data Center Optical Distribution Frame Solutions

The fiber optic terminal jumper storage panel is an optional filler panel that provides up to 5 meters
(16.4 feet) of slack storage for jumpers that run between terminal equipment and the rear ports of
an ODF terminal block in cross-connect applications. This slack storage capability allows for greater
flexibility in determining jumper lengths and allows for use of more standard length jumpers. This panel
is installed within the ODF frame lineup between ODF frames. The fiber optic terminal storage panels
are available in two different configurations depending on the way the ODF frame system is zoned.
ODF frames can be zoned by vertical or by frame. A 12-inch wide panel is available that serves two
verticals (one on each side) for use when frames are zoned by vertical. Also, 8-inch wide versions are
available that serve a single vertical (left or right) for use when frames are zoned by frame.

102094AE

TrueNet Structured Cabling

Fiber Optic Terminal Jumper Storage Panel

Data Center Optical Distribution


Frame Solutions
Frame Accessories
End Guard

TrueNet Structured Cabling

24"
(61 cm)

7'
(2.14 m)

ODF Frame
NGFB-MDF7A144-30

Isolation Pad shown with End Guard


NGF-ACCISOPEG24

End Guard
NGFB-ACCEGD007

Ordering Information
Dimensions
(HxWxD)

102094AE

5"
(12.7 cm)

Description

11/11

Data Center Optical Distribution Frame Solutions

End guards provide protection for the fibers entering and exiting frames at the end of a lineup. They are
designed for universal fit to be used on either end of the lineup.

End Guard
Use with FMDF Frames
Color: Black

7' x 5" x 24"


(2.14 m x 12.7 cm x 61 cm)

Isolation Pad - End Guard


A template for frame installation providing
isolation between the frame and the ground

www.te.com/adc

+1-952-938-8080

Catalog Number
NGFB-ACCEGD007

NGF-ACCISOPEG24

1-800-366-3891

264

Data Center Optical Distribution


Frame Solutions

Fiber Termination Blocks (FTBs) Factory Terminated Stubs

Preterminated Fiber
Termination Blocks Arrive
from the Factory with
Either IFC or OSP Cables

Fiber Cable Easily Uncoils


During Installation

Fiber Termination Block


Ships Inside the Drum

IFC Cables Loaded


into FTB

Definition of Variables

Block Style
General adapter type required in the FTB

Block Configuration
Maximum number of terminations that the FTB will accommodate when fully loaded

Block Orientation
Vertical column of the frame the FTB is to be mounted on

Cable Exit Direction


Direction the equipment jumpers or IFC cable will exit from the FTB

Adapter/Connector #1
Specific adapter/connector type required in the FTB. Refers to the adapter/connector type at the FTB

Connector #2
Specific connector type required at the cable end opposite the FTB

Cable Type
Type of cable to be terminated to the FTB

Cable Length
Required length of the cable terminated to the FTB

www.te.com/adc

+1-952-938-8080

1-800-366-3891

265

11/11

Data Center Optical Distribution Frame Solutions

FTBs are available with factory terminated indoor rated cable (IFC) in ribbon or stranded configurations.
All blocks are 100% factory tested to guarantee continuity and reliable connections. Factory terminated
FTBs make installation quick and easy, reducing labor costs. Before ordering, determine the block
orientation and cable exit direction. Factory terminated FTBs may be ordered with a left orientation
(mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame).
The cable exit direction will be either upward (cables terminated to the rear side of the block exit up
toward the top of the frame) or downward (cables terminated to the rear side of the block exit down
toward the bottom of the frame).

102094AE

TrueNet Structured Cabling

Configuration Information

Data Center Optical Distribution


Frame Solutions
SC Style FTBs with Factory Terminated Stubs
144-position Blocks

TrueNet Structured Cabling

L
R

Left
Right

4 Cable Exit Direction


U

Upward

Downward

5 Connector and Adapter Type #1


Singlemode
7 SC ultra polish
Multimode
9 SC
T SC aqua (10G)1

6 Connector Type #2
Singlemode
0 No connector/stub end
7 SC ultra polish
Multimode
0 No connector/stub end
9 SC

Cable Length
Standard Single-Ended
016 16 m (50')
023 23 m (75')
031 31 m (100')
046 46 m (150')
061 61 m (200')
077 77 m (250')
092 92 m (300')
122 122 m (400')
153 153 m (500')
Non-Standard
Use XXX for non-standard length in
meters

7 Cable Type (IFC Riser)2


Singlemode
ZD 144-fiber stranded
FJ
144-fiber ribbon
62.5/125 m Multimode Fiber
YM 144-fiber stranded
50/125 m Multimode Fiber
VZ 144-fiber stranded
50/125 m LOMMF 300m Multimode Fiber
WG 144-fiber stranded

TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of
10 Gigabit circuits.
Panels using TEs standard cable offering have a shorter lead time than panels using a specific cable manufacturer.
TE provides GR-409 compliant cable that meets or exceeds our high quality standards. Standard cable offering
above will use Corning SMF28-e, Sumitomo, Alcatel or similar singlemode fiber based on current market availability.
See previous page for definition of variables.

102094AE

3 Block Orientation

11/11

Data Center Optical Distribution Frame Solutions

Catalog Number
NGFB-TB1M __ __ __ __ __ __ __ __ __

Other configurations are available upon request. Please contact TE Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

266

Data Center Optical Distribution


Frame Solutions
LC Style FTBs with Factory Terminated Stubs
Catalog Number

11/11

102094AE

2 Block Capacity
M
Q

144
192

3 Block Orientation
L
R

Left
Right

4 Cable Exit Direction


U

Upward

Downward

5 Connector and Adapter Type #1


Singlemode
K LC ultra polish
Multimode
P LC
C LC aqua (10G)1

7 Cable Type (IFC Riser)2


Singlemode
ZD 144-fiber stranded
GT 192-fiber stranded (2 x 96)
FJ
144-fiber ribbon
EJ
192-fiber ribbon
62.5/125 m Multimode Fiber
YM 144-fiber stranded
MR 192-fiber stranded (2 x 96)
50/125 m Multimode Fiber
VZ 144-fiber stranded
JM 192-fiber stranded (2 x 96)
50/125 m LOMMF 300 m Multimode Fiber
WG 144-fiber stranded
TF
192-fiber stranded (2 x 96)

6 Connector Type #2
Singlemode
0 No connector/stub end
K LC ultra polish
Multimode
0 No connector/stub end
P LC

Cable Length
Standard Single-Ended
016 16 m (50')
023 23 m (75')
031 31 m (100')
046 46 m (150')
061 61 m (200')
077 77 m (250')
092 92 m (300')
122 122 m (400')
153 153 m (500')
Non-Standard
Use XXX for non-standard length in
meters

TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of
10 Gigabit circuits.
Panels using TEs standard cable offering have a shorter lead time than panels using a specific cable manufacturer.
TE provides GR-409 compliant cable that meets or exceeds our high quality standards. Standard cable offering
above will use Corning SMF28-e, Sumitomo, Alcatel or similar singlemode fiber based on current market availability.
See previous page for definition of variables.

Other configurations are available upon request. Please contact TE Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

267

Data Center Optical Distribution Frame Solutions

TrueNet Structured Cabling

NGFB-TB4 __ __ __ __ __ __ __ __ __ __

Data Center Optical Distribution


Frame Solutions

144-Position Right Upward FTB Shown

Note: When using the Fiber Optic Terminal Storage Panels, a cable exit UP block must be used.

102094AE

TrueNet Structured Cabling

FTBs without fiber can be ordered fully loaded


with adapters. Before ordering, determine
the block orientation and cable exit direction.
Unterminated FTBs may be ordered with a left
orientation (mounts on the left side of the frame)
or a right orientation (mounts on the right
side of the frame). The cable exit direction will
be either upward* (cables terminated to the
rear side of the block exit up toward the top of
the frame) or downward (cables terminated to
the rear side of the block exit down toward the
bottom of the frame). All blocks with adapters
only are configured to terminate single or dual
jumpers on the rear of the block. If a multifiber
breakout style cable (i.e., OSP/IFC) is to be
terminated to the rear of the block, a separate
clamping kit and replacement rear storage area
kit is required (see next page). FTBs cannot be
ordered with a combination of singlemode
and multimode adapters. If this combination
is desired, TE recommends purchasing a fully
loaded adapter only termination block, and
separate sliding adapter packs to customize the
block on-site.

11/11

Data Center Optical Distribution Frame Solutions

Fiber Termination Blocks (FTBs) Unterminated (Adapter Only)

Ordering information on next page.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

268

Data Center Optical Distribution


Frame Solutions

Fiber Termination Blocks (FTBs) Unterminated (Adapter Only)


Ordering Information
Description

Catalog Number

144-position Blocks
NGFB-TB4MRUP

LC (beige) adapters; cable exit up; LEFT block orientation

NGFB-TB4MLUP

LC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB4MRDP

LC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB4MLDP

Multimode SC
SC (beige) adapters; cable exit up; RIGHT block orientation

NGFB-TB1MRU9

SC (beige) adapter; cable exit up; LEFT block orientation

NGFB-TB1MLU9

SC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB1MRD9

SC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB1MLD9

10G Multimode LC

LC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUC

LC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUC

LC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDC

LC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDC

10G Multimode SC
SC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB1MRUT

SC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB1MLUT

SC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB1MRDT

SC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB1MLDT

102094AE

Singlemode LC
LC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUK

LC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUK

LC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDK

LC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDK

Singlemode SC

11/11

LC (beige) adapters; cable exit up; RIGHT block orientation

SC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB1MRU7

SC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB1MLU7

SC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB1MRD7

SC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB1MLD7

TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of
10 Gigabit circuits.

Ordering information continues on next page.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

269

Data Center Optical Distribution Frame Solutions

TrueNet Structured Cabling

Multimode LC

Data Center Optical Distribution


Frame Solutions

Fiber Termination Blocks (FTBs) Unterminated (Adapter Only)


Ordering Information
Description

Catalog Number

LC (beige) adapters; cable exit up; RIGHT block orientation

NGFB-TB4QRUP

LC (beige) adapters; cable exit up; LEFT block orientation

NGFB-TB4QLUP

LC (beige) adapters; cable exit down; RIGHT block orientation

NGFB-TB4QRDP

LC (beige) adapters; cable exit down; LEFT block orientation

NGFB-TB4QLDP

10G Multimode LC1


LC (aqua) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4QRUC

LC (aqua) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4QLUC

LC (aqua) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4QRDC

LC (aqua) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4QLDC

Singlemode LC

LC (blue) adapters with zirconia sleeves; cable exit up; RIGHT block orientation

NGFB-TB4MRUK

LC (blue) adapters with zirconia sleeves; cable exit up; LEFT block orientation

NGFB-TB4MLUK

LC (blue) adapters with zirconia sleeves; cable exit down; RIGHT block orientation

NGFB-TB4MRDK

LC (blue) adapters with zirconia sleeves; cable exit down; LEFT block orientation

NGFB-TB4MLDK

TE recommends the use of aqua colored adapters with laser optimized multimode fiber for identification of
10 Gigabit circuits.

Note: TE recommends the use of 1.7mm/ 1.6mm jumpers when deploying 192-position FTBs.

102094AE

TrueNet Structured Cabling

Multimode LC

11/11

Data Center Optical Distribution Frame Solutions

192-position Blocks

www.te.com/adc

+1-952-938-8080

1-800-366-3891

270

Data Center Optical Distribution


Frame Solutions
Fiber Termination Blocks (FTBs)
Configuration Information

Block Style
General adapter type required in the FTB

Block Configuration
Maximum number of terminations that the FTB will accommodate when fully loaded

Block Orientation
Vertical column of the frame the FTB is to be mounted on

Cable Exit Direction


Direction the equipment jumpers or OSP cable will exit from the FTB

Adapter Type
Specific adapter type required in the FTB

Cable Clamping/Block Conversion Kits


Adapter-only blocks are configured to accommodate single fiber jumpers or multifiber breakout
cables. If loading a preterminated intrafacility (IFC) cable or a preterminated OSP cable is desired,
additional hardware will be required. Block conversion kits are available to convert adapter only blocks
to blocks that will accept preterminated IFC or OSP style cables. The conversion kits contain the cable
management hardware, brackets and cable clamps required to convert the block.
The kit required will depend on the block style originally purchased.

Protective
Cover

Fanout
Bracket

Cable
Clamp

72-Position Block Loaded


with Jumpers

72-Position Block Loaded with


Multifiber Breakout Cable

72-Position Block with


Clamping Kit

11/11

Ordering Information
Description

Catalog Number

Block style originally purchased


144- or 192-position left up blocks
144- or 192-position right up blocks
144- or 192-position left down blocks
144- or 192-position right down blocks

NGFB-ACCRCMSLU
NGFB-ACCRCMSRU
NGFB-ACCRCMSLD
NGFB-ACCRCMSRD
Rear Cable Management Tray
for 144 Block Conversion Kit

www.te.com/adc

+1-952-938-8080

1-800-366-3891

271

Data Center Optical Distribution Frame Solutions

102094AE

TrueNet Structured Cabling

Definition of Variables

Data Center Optical Distribution


Frame Solutions

TrueNet Structured Cabling

Sliding adapter packs house groups of fiber optic


adapters and are mounted in Fiber Termination
Blocks to provide easy access to connectors.
Sliding Adapter Packs are available with SC and
LC adapters. The adapters come in packs of six
and eight depending on the adapter type and
the desired termination density. See table below
for configuration guidelines.

LC pack 144-position
(Style K)
SC pack
(Style K)

Sliding Adapter Pack Configuration Guidelines


Block
Configuration
144-Position (block code 'M')
192-Position (block code 'Q')

Adapter Type

Adapter Pack
Configuration

SC, LC
LC

6 Pack/6 Pack
8 Pack/8 Pack

Adapter Pack
Option
K (shown below)
J

Ordering Information
Description

Catalog Number1

144-position Blocks
NGF-SAPP0K00

Multimode LC

NGF-SAP90K00

102094AE

Multimode SC
10G Multimode LC

NGF-SAPC0K00

10G Multimode SC

NGF-SAPT0K00

Singlemode LC

NGF-SAPK0K00

Singlemode SC

NGF-SAP70K00

192-position Blocks

11/11

Data Center Optical Distribution Frame Solutions

Sliding Adapter Packs

Multimode LC

NGF-SAPP0J00

10G Multimode LC1

NGF-SAPC0J00

Singlemode LC

NGF-SAPK0J00

TE recommends the use of aqua colored adapters with laser


optimized multimode fiber for 10 Gigabit circuit identification.

Note: TE recommends the use of 1.7mm/ 1.6mm jumpers when deploying 192-position FTBs.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

272

Data Center Optical Distribution


Frame Solutions

11/11

102094AE

The Data Center Splice Cabinet is a high-density splice solution, housing up to 1,440 splices within a
23.6- by 11.8-inch footprint. Shipped complete with the necessary cable management, it features
slots which secure and protect the round splice trays and can hold up to sixty 12-fiber splice trays on
each vertical. The cabinet is shipped with lockable front doors and may be ordered for applications in
which the cables enter from above or below.

7'
(2.14 m)

12"
(30.5 cm)

24"
(61 cm)

Isolation Pad shown with OMX Cabinet


MX6-BAYTEMPLATE

OMX Splice Cabinet


MX6-BSPL-1440-U7
Doors Open and Closed

Ordering Information
Dimensions
(HxWxD)

Description
Fully Configured Splice Cabinet
Accommodates up to 1440 fiber splices
Cable enters from top
Color: black
Cabinet - Cable Exit Up
Cable enters from above
Color: black
Cabinet - Cable Exit Down
Cable enters from below
Color: black

7' x 24" x 12"


(2.14 m x 61 cm x 30.5 cm)

MX6-BSPL-1440-U7

MX6-BSPL-1440-D7

MX6-BAYTEMPLATE

Isolation Pad - Splice Cabinet


A template for cabinet installation providing
isolation between the cabinet and the ground

www.te.com/adc

Catalog Number

+1-952-938-8080

1-800-366-3891

273

Data Center Optical Distribution Frame Solutions

TrueNet Structured Cabling

Splice Cabinet

Data Center Optical Distribution


Frame Solutions
Accessories

Splice Wheel

TrueNet Structured Cabling

Splice Wheel
Accommodates up to 24 fiber splices, heat shink fusion chip
Accommodates 2x12 mass ribbon fusion splices

FST-DRS24-NT
FST-DRS12-MT

FST-DRS24-HS

Cable Clamps
Ordering Information
Description

Catalog Number

OMX Splice Frame Cable Clamps


For OSP Cable
For IFC Cable

FEC-ACCCLMP01
MX6-SPLIFCCLMP

102094AE

Catalog Number

Description

11/11

Data Center Optical Distribution Frame Solutions

Ordering Information

FEC-ACCCLMP01
www.te.com/adc

+1-952-938-8080

MX6-SPLIFCCLMP

1-800-366-3891

274

Data Center Optical Distribution


Frame Solutions
Accessories

Cable Clamp Kit

Cable clamp kit for active equipment patch cord includes:


1 each
1 each
2 each

Data Center Optical Distribution Frame Solutions

Cable clamp bracket


O-ring
Screws

Cable clamp kit for trunk cables includes:


Clamp cover
Clamps
0.5" Grommet (inner diameter)
0.6" Grommet (inner diameter)
0.7" Grommet (inner diameter)
#14 - #6 AWG split bolt
Shield bonding connector
1-foot lead wire
#6 AWG ring terminal lug
Clamp cover plate

1
2
1
1
1
1
1
1
1
1

each
each
each
each
each
each
each
each
each
each

Ordering Information
Description

Catalog Number

Cable clamp kit for equipment patch cords (included with fiber
termination blocks loaded with adapters only)

NGF-ACCCLMP04

Cable clamp kit* for trunk cables, dielectric cable without grounding
hardware (included with fiber termination blocks with IFC)

NGF-ACCCLMP08

* One NGF-ACCCLMP08 is also included with each cable clamp kit and block conversion kit (see page 273).

11/11

102094AE

TrueNet Structured Cabling

Cable clamp kits are available for securing IFC/OSP cable or equipment jumpers on the rear of the FTB.
Each FTB has three cable clamp mounting positions.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

275

Data Center Optical Distribution


Frame Solutions
Accessories

Frame Installation Kit

TrueNet Structured Cabling

Threaded rods
Heavy nuts, locks and flat washers
Nuts with springs
Unistrut and anchor kit

4 each, 5/8" 11" x 30"


12 each
4 each, 1/2" x 30" and shoulder washers
1 each, 10'

Overhead support kit includes:


Designation card holder
Two-bar channel
Framing clip with 0.56
Framing clip with 0.69
Clip J-bolt
Threaded rod
Hex nut
Hex nut

1
4
4
4
4
2
4
4

each
each
each
each
each,
each,
each,
each,

1/2"
5/8"
1/2"
5/8"

13" x 18" long


x 18" long
x 13"
x 11"

Ordering Information
Description

Catalog Number

Frame installation kit for


Computer floor

FDF-ACC146

Overhead support

RINST-TOP7

Standard Cross-Connect Patch Cord Lengths


Approximate
Patch Cord Length
Meters (Feet)

Total Number of
Sections Traversed1

102094AE

Computer floor kit includes:

Same frame
Adjacent frames
3 to 4
5 to 6
7 to 8
9 to 10

11/11

Data Center Optical Distribution Frame Solutions

Frame installation kits may be used on network frames and are seismic zone 4 rated.

6m
7m
8m
10 m
11 m

(18')
(23')
(26')
(33')
(36')

12 m (39')

Depending on office requirements, 11 or more frame sections may require the use of interbay tie panels.
For additional information, please call TE Technical Assistance Center, 1-800-366-3891.
For recommended cross-connect method and installation instructions, refer to User Manual ADCP-90-285.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

276

Introduction .................................................................... 278


TFP System ..................................................................... 280
Fiber Management Tray .................................................. 290
FL2000 System ............................................................... 301

FL1000 System ............................................................... 320


WMG Series Wall Mount Enclosures ............................... 326
Fiber Optic Specifications ................................................ 331
Fiber Optic Patch Cords .................................................. 333
Fiber Optic Connectors ................................................... 335
Accessories ..................................................................... 337

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

277

Fiber Connectivity Solutions

RMG Series Fiber Enclosures ........................................... 312

102094AE

TrueNet Structured Cabling

Fiber Connectivity Solutions

Fiber Connectivity Solutions


Introduction

Fundamentals of Fiber Cable Management

Bend radius protection: Micro- or macro-bends in fiber cable increase the risk of fiber breakage
and added attenuation, which in turn affect the long-term reliability of the network and increase
the cost of operations.
Adequate cable troughing with clear routing paths: Cable troughing should keep fiber runs
separate from heavier copper cables. Routing paths through the cable troughs should be clearly defined
and easy to follow, making access to individual fibers easier, quicker and safer, reducing the time
required for reconfiguration.
Easy accessibility to installed fibers: Access to installed fibers should ensure that any fiber can
be installed or removed without inducing improper bends on adjacent fiber. Accessibility is most
critical during network reconfiguration operations and directly impacts the cost of operations and
reliability of the network.
Vertical cable protection: Proper vertical cable management in panels or equipment bays
provides adequate support, cable protection and a transition from the vertical run to the back
of the equipment that does not damage the fiber.

102094AE

TrueNet Structured Cabling

Proper cable management practices make fiber networks less susceptible to accidental damage,
quicker to install, less expensive to own and operate over the long haul and easier to expand as
needs grow. To assure optimal network performance, TE's fiber solutions fully incorporate key cable
management concepts:

11`/11

Fiber Connectivity Solutions

In the backbone or to the desk, optical networks achieve peak performance with TE's fiber connectors,
patch cords, raceways, and panels featuring integrated cable management and bend
radius protection.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

278

Fiber Connectivity Solutions


Introduction

FL2000 Rack
Mount

FMT Rack
Mount

RMG Rack
Mount

FL1000 Wall WMG Wall


Mount Box Box

Sizes available
(standard LC
connectors)

48, 96, 192,


288

24, 48, 72,


96, 144, 192

12, 16, 24,


32, 72

36, 72, 144

24, 48, 96,


144

24, 48, 72

Wall Mount

No

Yes

Yes

No

Yes

Yes

Rack Mount

19"/23"/ETSI

19"/23"/ETSI

19"/23"/ETSI

19"/23"

No

No

Cabinet Mount

Yes

Yes

Yes

Yes

No

No

Interface Type

Angled
adapter pack

6pak

Sliding
LSX
Adapter Pack/ Compatible
Fixed Bulkhead Adapter Pack

6pak

LSX
Compatible
Adapter Pack

Degree of Cable Moderate


Management

Moderate

High

Fair

Moderate

Fair

Allows
additional
growth

Ideal

Ideal

Fair

Fair

Ideal

Fair

LC Compatible

Yes

Yes

Yes

Yes

Yes

Yes

Quad LC
Compatible

No

No

No

Yes

No

Yes

Best Applications for TrueNet Fiber Panel Portfolio


Name of Product

Best Application

Features at a Glance

FL2000 Series

Termination/Splice applications

Locking or latching door, within panel splice wheel,


all front access, modular left angle 6paks.

TFP Series

Rack or Cabinet mount near


servers, switches, routers
and SANs

Angled left/right adapter packs, highest density with


maximum cable management.

FMT Series

Near active equipment where


termination storage is required
in 1 or 2 rack unit footprint

Completely enclosed drawer with easy access to


fiber and high cable management and bend radius
protection.

RMG

Telecommunications rooms or
to terminate incoming fiber
trunks

Limited cable management, high density with


features price comparable to competitors' products.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

279

Fiber Connectivity Solutions

TFP Rack
Mount

102094AE

TrueNet Structured Cabling

TrueNet Fiber Panels and Wall Boxes

Fiber Connectivity Solutions

TrueNet Structured Cabling


102094AE

TE introduces the TFP Series rack mount fiber panels as an integral part of the TrueNet Fiber product
portfolio. The TFP Series fiber panels can be ordered in one, two, four and five rack unit sizes and
are completely modular to configure to a variety of applications. The unique modular adapter
packs incorporate TEs angled adapter design to allow easy access to each port and superior cable
management and bend radius protection.

Features
TFP panels combine the unique features of vertical cable guides and angle-left/angle-right
adapters, offering bend radius protection, intuitive routing and easy connector access
Rear access makes field termination or splicing fast and efficient. 1U and 2U versions feature convenient
sliding access to terminations and splicing
Sold separately for maximum flexibility with minimum lead time, TFP series adapter packs can also be
pre-configured at the factory for more efficient service turn-up
288-position high-density termination/splice in the space of just five rack units (8.75-inch)
Panels are equipped with adjustable mounting brackets to provide either 19- or 23-inch rack or cabinet
mounting (EIA or WECO) as well as 4- or 5-inch recess mounting
Field-installable vertical cable guides on either side of the panel provide bend radius protection and
management of fibers exiting the panel

11`/11

Fiber Connectivity Solutions

TFP Series Rack Mount Fiber Panels

Applications and Benefits


Best suited for rack or cabinet mounting in Horizontal and Equipment Distribution Areas
Modularity, functionality and density make the TFP ideal for mounting in close proximity to
servers, switches, routers and SANs

www.te.com/adc

+1-952-938-8080

1-800-366-3891

280

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels

11/11

Recommended
Applications

Multi-purpose high density modular solution ideal for cabinet or rack


mount applications near servers, switches, routers and SANS

Description

Termination, termination/splice

Chassis sizes
(in rack units)

1, 2, 4, and 5

Termination only
capacity using:
Simplex adapters 24, 48, 96, 144
Duplex adapters 24, 48, 96, 144
Small form factor (LC) 48, 96, 192, 288
Flexibility/
ablity to grow

Ideal for growth

Interconnect

Yes

Cross-connect

Yes

Accommodates
on-frame splicing

Yes. Built-in

Rear access

Yes

All-front-access

No

Customer premises
application

Ideal

19" mounting

Yes

23" mounting

Yes

Cabinet mount

Yes

Wall mount

No

Mix equipment with


fiber product?

Ideal

Vertical cable guide

Ships with every panel

Features at a Glance

Angled left/right adapter packs, highest density with maximum cable management
features.

Fiber Connectivity Solutions

102094AE

TrueNet Structured Cabling

Product Overview

Specifications
Storage/operating temperature:

40 to 85 C (-40 to 185 F)

Approximate weight (empty panel)


1 RU model:
2 RU model:
4 RU model:
5 RU model:

10.25 lbs
8.25 lbs
15.91 lbs
15.86 lbs

www.te.com/adc

+1-952-938-8080

1-800-366-3891

281

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels
Panel Configurations

TrueNet Structured Cabling

5 RU Chassis

APL

APR

2 RU Chassis
APL

APR

APL

APR

APL

APR

APL

APR

APL

APR

APL

APR

APL

APR

APL

APR

4 RU Chassis
APL

APR

APL

APR

APL

APR

APL

APR

APL = angle left adapter pack


APR = angle right adapter pack

102094AE

1 RU Chassis

11`/11

Fiber Connectivity Solutions

TFP Series chassis utilize modular adapter packs that are unique to either the right or left position of the
chassis. The left/right position must be specified to ensure proper adapter orientation and color order in
the backplane. The information below illustrates the vartious configurations for the three TFP chassis.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

282

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels
Chassis Dimensions

5.0

5.0

15.47
17.0

17.0

5.0

15.47
21.86

21.86

TOTAL WEIGHT O
1.72

1.72

TOTAL WEIGHT OF SKELETAL ASSEMBLY: 10.25 LBS

TOTAL WEIGHT OF SKELETAL ASSEMBLY: 10.25 LBS

Fiber Connectivity Solutions

TrueNet Structured Cabling

1 RU Model

2 RU Model

5.0

102094AE

5.0

15.50

15.50

TOTAL

17.0
20.24

17.0

3.42

3.42

11/11

20.24

TOTAL WEIGHT OF SKELETAL ASSEMBLY: 8.85 LBS

TOTAL WEIGHT OF SKELETAL ASSEMBLY: 8.85 LBS

www.te.com/adc

+1-952-938-8080

1-800-366-3891

283

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels

TrueNet Structured Cabling

16.40

15.75

5.0

4.0

8.73

102094AE

5 RU Model

11`/11

Fiber Connectivity Solutions

4 RU Model

www.te.com/adc

+1-952-938-8080

1-800-366-3891

284

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels
TFP Series Empty Chassis

Description

Height

Catalog Number

Termination only rack or cabinet mount panel, black


1 RU empty panel, black; accommodates
1 angle LEFT and 1 angle RIgHT adapter packs;
T-handle latch close

1.75"

TFP-1TT00-000B

2 RU empty panel, black; accommodates


2 angle LEFT and 2 angle RIGHT adapter packs;
T-handle latch close

3.50"

TFP-2TT00-000B

4 RU empty panel, black; accommodates


4 angle LEFT and 4 angle RIGHT adapter packs;
T-handle latch close

7.00"

TFP-4TT00-000B

5 RU empty panel, black; accommodates


6 angle LEFT and 6 angle RIGHT adapter packs;
T-handle latch close

8.75"

TFP-5TT00-000B

Accessories
Heat Shrink Fusion Splice Tray

FST-HS-48

Velcro Kit for Splice Tray

TFP-VELSTP

Blank plates

TFP-00AP00

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

285

Fiber Connectivity Solutions

Ordering Information

102094AE

TrueNet Structured Cabling

The TFP series chassis can be purchased without adapter packs. In this form, the end-user can mix and
match any combinations of modular TFP adapter packs or simply utilize a grow as you go approach to
their network.

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels

The TFP modular adapter packs can only be used with the TFP series panels. Each adapter pack contains
labels that make it able to be loaded correctly in only one side of the panel. These craft friendly labels
help insure correct installation. The TFP adapter packs are not interchangeable with RMg, WMg,
FL1000 or FL2000 panels.

Ordering Information
Description

Catalog Number

OM1/OM2 Multimode Adapter only Packs


SC duplex adapters, beige color
6 adapters or 12 fiber ports per adapter pack
Angle LEFT adapter only pack

TFP-12APLC3

Angle RIGHT adapter only pack

TFP-12APRC3

LC adapters, beige color


12 adapters or 24 fiber ports per adapter pack
Angle LEFT adapter only pack

TFP-24APLQ1

Angle RIGHT adapter only pack

TFP-24APRQ1

OM3/OM4 multimode adapter only packs


SC duplex adapters with zirconia sleeve, aqua color
6 adapters or 12 fiber ports per adapter pack1
Angle LEFT adapter only pack

TFP-12APLC4

Angle RIGHT adapter only pack

TFP-12APRC4

LC adapters with zirconia sleeve, aqua color


12 adapters or 24 fiber ports per adapter pack1

102094AE

TrueNet Structured Cabling

The TFP series offers a variety of standard modular adapter packs to accommodate most applications.
The modular design is user-friendly and offers maximum flexibility to the end-user. TEs standard
adapter pack offerings are multimode LC (beige), multimode LC (aqua), multimode SC duplex (beige),
multimode SC duplex (aqua), singlemode LC and singlemode SC adapters with and without pigtails.
(For other adapter pack offerings, see the custom configuration section).

Angle LEFT adapter only pack

TFP-24APLQ2

Angle RIGHT adapter only pack

TFP-24APRQ2

Singlemode Adapter only Packs

SC duplex adapters with zirconia, blue color


6 adapters or 12 fiber ports per adapter pack
Angle LEFT adapter only pack

TFP-12APLC8

Angle RIGHT adapter only pack

TFP-12APRC8

LC adapters with zirconia sleeve, blue color


12 adapters or 24 fiber ports per adapter pack

11`/11

Fiber Connectivity Solutions

TFP Series Standard Adapter Packs

Angle LEFT adapter only pack

TFP-24APLQ5

Angle RIGHT adapter only pack

TFP-24APRQ5

TE recommends the use of aqua colored adapters with laser-optimized multimode fiber for 10 Gigabit
applications for circuit identification.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

286

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels

TFP Series Standard Adapter Packs with Pigtails


Ordering Information
Catalog Number

Multimode adapter packs with OM3 50/125 LOMMF 300 m

SC duplex adapters with zirconia sleeve, aqua color


6 adapters or 12 fiber ports per adapter pack
Angle LEFT adapter only pack

TFP-12APLC4DE3

Angle RIGHT adapter only pack

TFP-12APRC4DE3

LC adapters with zirconia sleeve, aqua color


12 adapters or 24 fiber ports per adapter pack
Angle LEFT adapter only pack

TFP-24APLQ2DE3

Angle RIGHT adapter only pack

TFP-24APRQ2DE3

Singlemode adapter packs with singlemode pigtails

Angle LEFT adapter only pack

TFP-12APLC8SB3

Angle RIGHT adapter only pack

TFP-12APRC8SB3

LC adapters with zirconia sleeve, blue color


12 adapters or 24 fiber ports per adapter pack

Angle LEFT adapter only pack

TFP-24APLQ5SB3

Angle RIGHT adapter only pack

TFP-24APRQ5SB3

TE recommends the use of aqua colored adapters with laser-optimized multimode fiber for 10 Gigabit
applications for circuit identification.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

287

Fiber Connectivity Solutions

SC duplex adapters with zirconia, blue color


6 adapters or 12 fiber ports per adapter pack

102094AE

TrueNet Structured Cabling

Description

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels
TFP Series Custom Adapter Packs

TrueNet Structured Cabling

Pigtail Length

Number of Fiber Ports


12

12 fiber ports: 6 LC adapters;


6 SC duplex adapters; 12 ST
adapters

24

24 fiber ports: 12 LC adapters

LEAVE
BLANk

Adapters only

3 meter pigtails

Pigtail Type

Pack Orientation
L

angle left

LEAVE
BLANk

Adapters only

angle right

Singlemode stranded

Multimode stranded

Adapter Style

Fiber Size

Multimode Connectors
SC duplex (beige)

LEAVE
BLANk

Adapters only

C3
C4

SC duplex (aqua) with zirconia sleeve

OM1 62.5/125 multimode

Q1

LC (beige)

Q2

LC (aqua) with zirconia sleeve

OM3 50/125 LOMMF


300 m

T1

ST

Singlemode

Singlemode Connectors
C8

SC UPC duplex (blue)

A1

SC APC duplex (green)

Q5

LC UPC (blue)

T2

ST UPC

102094AE

Catalog Number
TFP - __ AP __ __ __ __ __

11`/11

Fiber Connectivity Solutions

TEs TFP modular adapter packs are also available in additional adapter styles of 3 meter pigtails. Please
note, these products are non-standard or custom configurations based on the end users needs.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

288

Fiber Connectivity Solutions


TFP Series Rack Mount Fiber Panels

Pre-configured TFP Series Custom Termination/Splice Fiber Panels


TEs TFP series fiber panels are available to be shipped with factory installed adapter packs and/or
preterminated pigtail assemblies which simplifies the ordering process and reduces installation and costs.
These products are non-standard or custom configurations based on the end users needs.

Catalog Number
TFP - __ __ __ __ - __ __ __ B

Splice Deck Type

Panel Size
1U (1.75")

Accommodates 2 adapter
packs; T-handle latch

1L

1U (1.75")

Accommodates 2 adapter
packs; key-lock latch

2T

2 RU (3.50")

Accommodates 4 adapter
packs; T-handle latch

2L

2U (3.50")

Accommodates 4 adapter
packs; key-lock latch

5T

5 RU (8.75") Accommodates 12 adapter


packs; T-handle latch

5L

5 RU (8.75") Accommodates 12 adapter


packs; key-lock latch

None

Heat shrink fusion

Loaded Adapter Packs


02

2 adapter packs loaded

04

4 adapter packs loaded

06

6 adapter packs loaded

08

8 adapter packs loaded

12

12 adapter packs loaded

Connector Style
Panel/Pigtail Type

Multimode Connectors

Termination only with adapter packs, no


pigtails

C3

SC duplex (beige)

Termination/Splice with adapter packs with


singlemode stranded pigtails

C4

SC duplex (aqua) with zirconia sleeve

Q1

LC (beige)

Q2

LC (aqua) with zirconia sleeve

T1

ST

D
E

Termination/Splice with adapter packs with


OM3 50/125 LOMMF 300 m stranded pigtails
Termination/Splice with adapter packs with
OM162.5/125 multimode stranded pigtails

Singlemode Connectors
C8

SC UPC (blue)

A1

SC APC (green)
LC UPC (blue)
ST UPC

11/11

Q5
T2

www.te.com/adc

+1-952-938-8080

1-800-366-3891

289

Fiber Connectivity Solutions

1T

102094AE

TrueNet Structured Cabling

* Not all configurations available. Please call customer service for additional information.

Fiber Connectivity Solutions


Fiber Management Tray
Introduction

TrueNet Structured Cabling


102094AE

11`/11

Fiber Connectivity Solutions

TEs Fiber Management Trays (FMT) provide a flexible, economical approach to handling your networks
most vital elements by offering four different designs. Termination, termination/splicing, termination/
storage, and slack storage designs are offered with TEs modular, all-front-access design. The FMT is
ideal for cabinet applications.
Sliding Radius Limiter
Sliding radius limiters provide ultimate fiber
management by addressing one of the most
critical elements of fiber cable management:
bend radius protection.
By controlling the movement of fibers into the
drawer, error-proof slack loop management is
maintained, ensuring proper bend radius
protection. This is crucial to protecting fiber,
eliminating service failures and decreasing costs.

Sliding Adapter Pack


Sliding adapter packs allow easy access for
connecting jumpers and cleaning connectors,
ensuring that any fiber can be installed or
removed without disturbing adjacent fibers.
That means a significant reduction in connector
installation/reconfiguration time.
Modular Design
TEs modular design offers the value of a single
interface for performing multiple tasks in your
network. By employing a 1 or 2 RU modular
drawer, network technicians have familiar access
to terminating, splicing and storing fiber. This
cable management approach translates to time
and money saved for moves, adds and changes.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

290

Fiber Connectivity Solutions


Fiber Management Tray

Secure
Cable to
Rack

Tie Lances
(2 on Each Side)

11/11

Storage
Radius
Limiters

Right Rear
Radius Limiter

Mounting
Bracket (2)

Edge
Protectors (6)

Sliding
Adapter
Packs

Lock
(optional)

Sliding Radius
Trumpet Flare (2)
FMT Sliding
Radius Limiter Routing

12-Termination/Storage Drawer, Universal Entry

Termination-Only Drawers
Routing and Securing Cable Typical Configuration
This FMT accommodates 24-, 32-, 48-, 72- or 96- standard single circuit access connectors in 1 or 2 RU
drawers. It is ideal for interconnect applications that will experience minimal network reconfiguration.
Termination and Splice Drawers
This FMT has termination/splicing capability for 12-, 16- or 24-fibers within 1 RU or 48-fibers in 2 RU.
Splice trays can be placed on the left and right side of the FMT, offering great flexibility in ordering the
panel to fit your specific network application.
Slack Storage Drawers
These FMTs properly manage and protect excess optical jumper length at the equipment frame. They
may be used in conjunction with other FMT solutions or as a stand-alone slack storage solution at the
equipment frame. Both bulk and discrete storage solutions are available to accommodate industrystandard jumper configurations.
Sliding Radius Limiters
Minimize fiber movement during drawer usage and the need for a long slack loop.
Sliding Adapter Packs
Two adapter/connectors in 1 RU panels and six in 2 RU panels provide easy hand access for
connecting cables and cleaning connectors.
Edge Protectors
Protect cables from sharp angles at bend points in the cable routing.
Rear Radius Limiters
Maintain a protective minimum bend radius for cables routed into the FMT.
Tie Lances
Secure fibers at the ingress/egress point for additional cable management.
Storage Radius Limiters
Provide slack storage for cable terminated within the FMT.
Lockable
Allows controlled accessibility to the drawer.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

291

Fiber Connectivity Solutions

102094AE

TrueNet Structured Cabling

Left Rear
Radius Limiter

Fiber Connectivity Solutions


Fiber Management Tray
Product Overview

TrueNet Structured Cabling

Small to medium fiber count application. Offers the secure fiber protection that
comes with a drawer solution coupled with a high degree of cable management.
Ideal for mixed use with active equipment in either frame or cabinet applications.

Description

Termination, termination/splice, slack storage

Chassis sizes
(in rack units)

1, 2

Termination only
capacity using:
Simplex adapters 32, 72
Duplex adapters n/a
Small form factor (LC) 32, 96
Interconnect

Ideal

Cross-connect

Yes

Accommodates
on-frame splicing

Yes. Built-in

Rear access

Not required

All-front-access

Yes

Customer premises
application

Ideal

19" mounting

Yes

23" mounting

Yes

Cabinet mount

Yes

Wall mount

Yes. A wall mount kit is available

Mix equipment with


fiber product?

Ideal

Vertical cable guide

VCg available as separate item

Features at a Glance

Completely enclosed drawer with high degree of cable management and bend
radius protection.

102094AE

Recommended
Applications

11`/11

Fiber Connectivity Solutions

FMT Rack Mount

www.te.com/adc

+1-952-938-8080

1-800-366-3891

292

Fiber Connectivity Solutions


Fiber Management Tray

1 Rack Unit Specifications

11.01"
(27.97cm)

24 Term/Splice Drop-In Plate with Universal 19


EIA/WECO Brackets and Optional Lock
Shown in Views for Reference Only

C
A
B
1.7"
(4.32cm)

Universal mounting bracket,


EIA or WECO rack mount

Front view
Shown without sliding radius limiters

Ordering
Code

Configuration

19" EIA (5" recess)

18.32" (46.5cm)

1.25" (3.2cm)

5.0" (12.7cm)

11/11
www.te.com/adc

+1-952-938-8080

Fiber Connectivity Solutions

17.26"
(43.84cm)

8 to 10lbs (3.7 to 4.5kg)


Termination only (24 or 32 fibers)
Termination/storage (12, 16, or 24 terminations)
Bulk Storage
3mm outer diameter cable: 32 cables, length 2.5m each
2mm outer diameter cable: 48 cables, length 2.5m each
1.7mm outer diameter cable: 60 cables, length 4m each
Discrete storage
3mm outer diameter cable: 16 cables, length 1.7m each
2mm outer diameter cable: 16 cables, length 2m each
1.7mm outer diameter cable: 16 cables, length 2.5m each
Termination/splicing (12, 16, or 24 splices)
Fiber Tie-Off
Point (4) Places

102094AE

TrueNet Structured Cabling

PHYSICAL
Approximate Weight:
Configuration Options and Capacity:

1-800-366-3891

293

Fiber Connectivity Solutions


Fiber Management Tray

1 Rack Unit Slack Storage

TrueNet Structured Cabling

Discrete Storage Drawer

Capacity
Slack storage type

3mm cable

2mm cable

1.7mm cable

Bulk

32 cables, 2.5m each

48 cables, 2.5m each

60 cables, 4m each

Discrete

16 cables, 1.7m each

16 cables, 2m each

16 cables, 2.5m each

Ordering Information
Description

Catalog Number

1RU Bulk storage drawer, no lock, 19" mounting -5" recess; black

FMT-DBS000000-A00B

1RU Discrete storage drawer, no lock, 19" mounting -5" recess; black

FMT-DDS000000-A00B

102094AE

Bulk Storage Drawer

11`/11

Fiber Connectivity Solutions

The slack storage trays offer bulk storage for up to 60 fibers, and discrete slack storage for up
to 16 fibers. This all-front-access tray mounts in 19- or 23-inch racks. Sliding radius limiters provide
cable management for incoming and outgoing fibers. Unit comes with black faceplate and chassis.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

294

Fiber Connectivity Solutions


Fiber Management Tray

1 RU Adapter-Only Fiber Termination Drawers

Provides termination for 24- or 32-fibers in an all-front-access design


Mounts in 19- or 23-inch racks
Sliding radius limiters provide cable management for incoming and outgoing fibers

Catalog Number
FMT- D R T __ __ 0 A 0 __ - A __ __ B

0
A

Number of Ports
24 24 SC adapters/
12 LC adapters
32 32 SC adapters/
16 LC adapters

Standard singlemode and


multimode adapter colors
Aqua multimode adapters for
OM3/OM4 applications

Connector and Adapter Type


Multimode
9 SC
6 LC
Singlemode
7 SC ultra polish
8 LC ultra polish

Lock Type
0 No lock
1 Lock, key type #1
All 19- or 23- inch mounting
brackets are reversible and can
mount in EIA or WECO racks.

11/11

Other configurations are available upon request. Please contact TE Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

295

Fiber Connectivity Solutions

1 RU 32-Termination
Adapter-Only Drawer

1 RU 24-Termination
Adapter-Only Drawer

102094AE

TrueNet Structured Cabling

Features

Fiber Connectivity Solutions


Fiber Management Tray

1 Rack Unit Termination / Splice Drawer with Adapters and Pigtails

TrueNet Structured Cabling


102094AE

Features
Terminates and splices 12-, 16- or 24-fibers in an all front access design
Mounts in 19- or 23-inch racks
Sliding radius limiters provide cable management for incoming and outgoing fibers
Panels loaded with pigtails come with color-coded 900 m pigtails

1 RU 12-Termination/Splice Drawer 1 RU 24-Termination/Splice Drawer 1 RU 24-Termination/Splice Drawer


(Right Splice Entry)
(Right Splice Entry)
(Left Splice Entry)

Catalog Number
FMT - D __ __ __ __ 0 __ __ __ - A __ __ B
Number of Ports
12 12 SC adapters / 6 LC adapters
24 24 SC adapters / 12 LC adapters

Drawer Configuration
TL Term splice with splice tray
(left splice entry)
TR Term splice with splice tray
(right splice entry)
0
A

Lock Type
0 No lock
1 Lock, key type #1

Standard singlemode and


multimode adapter colors
Aqua multimode adapters for
OM3/OM4 applications

Chip
0
2
3

11`/11

Fiber Connectivity Solutions

This configuration features fixed bulkhead style adapter plates and accommodates singlemode and
multimode SC and LC adapters. The tray can be ordered with adapters only, or with pigtails. Unit
comes with black faceplate and chassis.

Connector and Adapter Type


Multimode
9 SC
6 LC
Singlemode
7 SC UPC
8 LC UPC

Type (mini splice tray)


N/A
Heat shrink (single fiber fusion)
Mechanical (mass fusion)

Pigtail or Adapter Type


A Adapter-only
U Singlemode stranded pigtails
R Singlemode ribbon pigtails
J OM3 multimode pigtails
All 19- or 23-inch mounting brackets
are reversible and can mount in EIA
and WECO racks.

Other configurations are available upon request. Please contact TE Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

296

Fiber Connectivity Solutions


Fiber Management Tray

2 Rack Unit Termination with Adapters Only

Sliding adapter pack


shown in access position
72-termination with adapters only

Catalog Number

0
A

Number of Loaded Ports


72 72 SC adapters
96 48 LC adapters

Standard singlemode and


multimode adapter colors
Aqua multimode adapters
for OM3/OM4 applications

Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2

Connector/Adapter Style
Multimode
9 SC
6 LC
Singlemode
7 SC UPC
8 LC UPC

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

297

Fiber Connectivity Solutions

FMT-GRT __ __ A 0 __ - A __ B

102094AE

TrueNet Structured Cabling

The termination-only fiber management tray provides termination for 72 fibers with SC adapters or 96
fibers with LC adapters in an all-front-access design. Sliding radius limiters provide cable management
for incoming and outgoing fibers. Unit comes with black faceplate and chassis.

Fiber Connectivity Solutions


Fiber Management Tray

TrueNet Structured Cabling

48-termination/splice

Catalog Number
FMT-GTL __ __ 0 __ __ __ - A __ __ B

0
A

Number of Ports Loaded


48 48 SC adapters/
24 LC adapters
64 32 LC adaptes

Standard singlemode and


multimode adapter colors
Aqua multimode adapters
for OM3/OM4 applications

Lock
0
1
2

Connector/Adapter Style
Multimode
9 SC
6 LC
Singlemode
7 SC UPC
8 LC UPC

Type
No lock
Lock, key type 1
Lock, key type 2

Chip Style (mini splice tray)


0 None
2 Heat shrink
3 Mechanical
4 High-density heat
shrink fusion 1

Cable or Adapter Type


A Adapters only
0 No adapters
J OM3 multimode stranded pigtails
U Singlemode Maxi-Strip pigtails

For use with LC 64 fiber splicing applications.

102094AE

The termination and splice tray terminates


and splices fibers in an all-front-access design. Sliding
radius limiters provide cable management for
incoming and outgoing fibers. Panels loaded with
pigtails come with color-coded 900 micron pigtails.
Unit comes with black faceplate and chassis.

11`/11

Fiber Connectivity Solutions

2 Rack Unit Termination and Splice

www.te.com/adc

+1-952-938-8080

1-800-366-3891

298

Fiber Connectivity Solutions


Fiber Management Tray

1 RU Drawer Accessories
Mini Splice Tray

Cable

Cable

Ordering Information
Description

Catalog Number

Bare fusion
Heat shrink (single fiber fusion)
Mechanical (mass fusion)

FL1-M-FT
FL1-M-HS
FL1-M-MT

32 mm (1.25") Offset
FMT-ACCCLMP02
From Rack
1.25" Offset
FMT-ACCCLMP02
from Rack

Rack

6 mm
(0.25") Offset
FMT-ACCCLMP01
From
Rack
0.25"
Offset
from Rack
FMT-ACCCLMP01

Fiber Connectivity Solutions

Cable Clamp Kit

Wall Mount Kit, Cable Clamp Kit


and Vertical Cable guide
The cable clamp kit provides a means of securing cable entering
the drawer. The wall mount kit is required for wall mount
applications. Vertical cable guide safely routes fiber cable on
the frame.

Ordering Information
Description

Catalog Number

Wall mount kit


Cable clamp kits
6 mm (0.25") offset from frame
32 mm (1.25") offset from frame
Vertical cable guide (VCG)

FMT-ACCWLMT01
FMT-ACCCLMP01
FMT-ACCCLMP02
FMT-ACCVCG01B
Vertical Cable Guide

11/11

102094AE

TrueNet Structured Cabling

For use with splicing configurations in the 1 RU FMT.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

299

Fiber Connectivity Solutions


Fiber Management Tray

2 RU Drawer Accessories
Mini Splice Tray

Cable

TrueNet Structured Cabling

Ordering Information
Description

Catalog Number

Bare fusion
Heat shrink (single fiber fusion)
Mechanical (mass fusion)

FST-M-FT
FST-M-HS
FST-M-MT

32 FMT-ACCCLMP02
mm (1.25") Offset
From Rack
1.25"
Offset
FMT-ACCCLMP02
from Rack

Rack

6 mm (0.25") Offset
FMT-ACCCLMP01
From Rack
0.25" Offset
FMT-ACCCLMP01
from Rack

Cable Clamp Kit

Cable Clamp Kit and Vertical Cable guide


The cable clamp kit provides a means of securing cable entering
the drawer. Vertical cable guide safely routes fiber cable on
the frame.
Ordering Information
Description

Catalog Number

Cable clamp kit


6 mm (0.25") offset from frame
32 mm (1.25") offset frame
Vertical cable guide (VCG)

FMT-ACCCLMP01
FMT-ACCCLMP02
FMT-ACC21B

Vertical Cable Guide

102094AE

Cable

11`/11

Fiber Connectivity Solutions

For use with splicing configurations in the 2 RU FMT.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

300

Fiber Connectivity Solutions

FL2000 termination/splice chassis

FL2000 termination only chassis

The economical and flexible FL2000 series of fiber optic products is ideal for small fiber counts and
can be used in moderate fiber count applications as well by combining various panels.

Features
Designed for 19-inch (48.26cm) EIA rack or cabinet environment; optional brackets are available to
accommodate 23-inch (58.42cm) rack or cabinet mounting, or virtually any mounting application
A full line of options and accessories ensures compatibility with existing optical equipment
All FL2000 panels accommodate the modular FL2000 6pak plug-ins. 6paks are available in all connector
styles and can be ordered as needed
TEs patented removable angled retainers allow easy access for single fiber maintenance
FL2000 panels and feature superior vertical cable protection and management
Rack mount panels are hinged on one side, allowing full access to the rear of the front plate and the
interior of the panel
Rack mount panels can be wall mounted
The new FL2000 splice wheel allows easy roll-up of pigtail and buffer tube lengths and superior bend
radius protection

Applications
Fully adaptable for medium or small count fiber main distribution frame (MDF) or telephone closets for
both wall and rack mount applications
Provides termination, splicing and storage capabilities for in-building cables, outside plant cables and
active equipment fiber patch cords

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

301

Fiber Connectivity Solutions

Modular design offers maximum flexibility to satisfy both current needs and future growth requirements

102094AE

TrueNet Structured Cabling

FL2000 System

Fiber Connectivity Solutions


FL2000 System

TrueNet Structured Cabling

Multi-purpose modular solution ideal for cabinet, rack, wall mount or medium
size frame applications. Ideal for small to medium fiber counts.

Description

Termination, termination/splice

Chassis sizes
(in rack units)

1, 2, 3, 5, 6 (termination only chassis)


2, 3, 5, 8, 10 (termination/splice chassis)

Termination only
capacity using:
Simplex adapters 12, 24, 48, 72, 96
Duplex adapters 12, 24, 48, 72, 96
Small form factor (LC) 24, 48, 72, 144, 192
Flexibility/
ablity to grow

Ideal for growth

Interconnect

Yes

Cross-connect

Yes

Accommodates
on-frame splicing

Yes. Built-in

Rear access

Not required

All-front-access

Yes

Customer premises
application

Ideal

19" mounting

Yes

23" mounting

Yes

Cabinet mount

Yes

Wall mount

Yes

Mix equipment with


fiber product?

Ideal

Vertical cable guide

Ships with every panel

Features at a Glance

Locking or latching door, within panel splice wheel, all front access, modular angle
left 6paks.

102094AE

Recommended
Applications

11`/11

Fiber Connectivity Solutions

Product Overview

www.te.com/adc

+1-952-938-8080

1-800-366-3891

302

Fiber Connectivity Solutions


FL2000 System

Empty Termination/Splice Panels, Black

4.95"
(12.58 cm)

- 19" (48.26cm) EIA racks or cabinets,


standard 5" (12.7cm) recess

5.25"
(13.34 cm)

- Wall mounting option available


- Other mounting kits available
Hinged on left front side 1 for complete access
to interior of termination section
Ability to quickly and easily configure, utilizing
the 6pak assemblies (ordered separately)

Termination/splice panel

Complete line of accessories including locks


for security
Uses TE splice wheels or splice decks
1

Right hinged also available

Ordering Information
Panel Height

Description
Termination/splice panel, black
12-position
24-position
48-position
72-position

3.5"
5.25"
8.75"
14"

Splice wheel with splice chip


Heat shrink fusion
Mechanical
Nortel

(8.89cm)
(13.34cm)
(22.23cm)
(35.56cm)

Catalog Number
FL2-12TS350-B
FL2-24TS525-B
FL2-48TS875-B
FL2-72TS140-B
FST-DRS12-HS
FST-DRS12-MT
FST-DRS24-NT

11/11

Mounting kits sold separately.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

303

Fiber Connectivity Solutions

TrueNet Structured Cabling

Mounting

102094AE

19.60"
(49.79 cm)

10.14"
(25.76 cm)

Features

Fiber Connectivity Solutions


FL2000 System

Empty Termination Panels, Black


1.75" (4.45cm)

8.75" (22.23cm)

TrueNet Structured Cabling


102094AE

11`/11

Fiber Connectivity Solutions

Features
Mounting
- 19" (48.26cm) EIA rack or cabinets,
standard 5" (12.7cm) recess
- Wall mounting option available
- Other mounting kits available

3.50" (8.89cm)
10.50" (20.67cm)
5.25" (13.34cm)

Hinged on left front side 1; allows full access


to rear of front plate and interior of panel
FL2000 6pak adapter plug-ins ordered
separately
Constructed of high strength aluminum
Equipped with removable metal doors with
Plexiglas windows
Designation labels included with each panel

10.14"
(25.76cm)

19.60"
(49.79cm)

4.95"
(12.58cm)

5.25"
(13.34cm)

Complete line of accessories including locks


for security
1

Right hinged also available

Ordering Information
Description
Rack or cabinet mount panel, black
Includes vertical cable management
trough
12 fiber capacity
24 fiber capacity
36 fiber capacity
48 fiber capacity
72 fiber capacity
96 fiber capacity

Panel Height

Catalog Number

1.75" (4.45cm)
3.50" (8.89cm)
5.25" (13.34cm)
5.25" (13.34cm)
8.75" (22.23cm)
10.50" (26.67cm)

FL2-12RPNL-B
FL2-24RPNL-B
FL2-36RPNL-B
FL2-48RPNL-B
FL2-72RPNL-B
FL2-96RPNL-B

24 fiber capacity

Accessories
Wall mount bracket, blackneeded
for 12 fiber capacity panel only

FL2-ACC008

Cable clamp kitOne per cable


recommended
Outer diameter 0.2" to 0.8"
Outer diameter 0.7" to 1.0"
Cable clamp kit for 12 fiber capacity
panel only

FL2-ACC007
FL2-ACC021
FL2-ACC033

Bonding/grounding kit

FL2-ACC006

Mounting kits sold separately.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

304

Fiber Connectivity Solutions


FL2000 System

Empty Splice Panels, Black

Offers combination of splicing protection


and associated fiber/pigtail storage
Splice panel can be mounted in conjunction
with any FL2000 termination panel or as a
stand-alone splice panel
Occupies same footprint and offers
same mounting options as FL2000
termination panels

4.95"
(12.58cm)

3.50"
(8.89cm)

Fiber splice module


(48 fiber capacity
module shown)
TOP
SIDE

Accepts the TE splice wheel for


efficient management of fiber cable
and splice protection

CLEAR
COVERS

Accepts the traditional TE splice deck

SPLICE
DECK

BOTTOM
SIDE

Splice deck with


splice chip (black)

SPLICE CHIP(S)
(HEAT SHRINK
SHOWN)

Splice wheel with


splice chip (black)

Ordering Information
Description
Splice panel for splice wheel, black
(Accepts splice wheel only)
48 fiber capacity
96 fiber capacity
144 fiber capacity

Panel Height

Catalog Number

3.5" (8.89cm)
7" (17.78cm)
8.75" (22.23cm)

FL2-48SPNL2-B
FL2-96SPNL2-B
FL2-144SPNL2-B

Splice wheel with splice chip


Heat shrink fusion
Mechanical
Nortel

FST-DRS12-HS
FST-DRS12-MT
FST-DRS24-NT

Splice panel for splice deck for existing installations, black


(Also accepts splice wheel)
48 fiber capacity
96 fiber capacity
144 fiber capacity

3.5" (8.89cm)
7" (17.78cm)
8.75" (22.23cm)

Cable clamp kit (kit of 1)


Outer diameter 0.2" to 0.8"
Outer diameter 0.7" to 1.0"

FL2-48SPNL-B
FL2-96SPNL-B
FL2-144SPNL-B
FL2-ACC007
FL2-ACC021

Mounting kits sold separately

www.te.com/adc

+1-952-938-8080

1-800-366-3891

305

Fiber Connectivity Solutions

102094AE

TrueNet Structured Cabling

Features

11/11

19.60"
(49.79cm)

10.14"
(25.76cm)

Fiber Connectivity Solutions


FL2000 System

6pak Connector Plug-Ins

102094AE

TrueNet Structured Cabling

Completely interchangeable between FL2000


panel and wall box products

6pak plug-in (shown with


singlemode duplex adapters)

Can be ordered with all standard types


of simplex and duplex single and multimode
adapters and connectors
Feature TEs patented removable
angled retainers which provide superior
fiber management
No tools required to install into FL2000
boxes or panels

6pak plug-in (shown with


multimode duplex adapters)

Can be ordered with adapters only, or for


quick and easy installation, with
preterminated 3 meter (9.84') or 5 meter
(16.4') pigtails

6pak blank plug-in

Ordering Information

Description

Catalog Number

Multimode
SC
SC (aqua1)
ST
SC (duplex)
SC (aqua1, duplex)
LC
LC (aqua1)

FL2-6PMMSC
FL2-6PMMSC-A
FL2-6PMMST
FL2-6PMMDSC
FL2-6PMMDSC-A
FL2-6PMMLC
FL2-6PMMLC-A

Singlemode
SC
ST
SC (duplex)
LC

FL2-6PSMSC
FL2-6PSMST
FL2-6PSMDSC
FL2-6PSMLC

6pak blank plug-in

FL2-6PBLNk

6pak plug-in (shown with


singlemode simplex adapters)

6pak plug-in (shown with


multimode simplex adapters)

TE recommends the use of aqua colored adapters


with laser optimized multimode fiber applications for
10 Gigabit circuit identification.

11`/11

Fiber Connectivity Solutions

Features

www.te.com/adc

+1-952-938-8080

1-800-366-3891

306

Fiber Connectivity Solutions


FL2000 System

6pak Connector Plug-Ins With Adapters and Pigtails

Available with preterminated 5 meter (16.4')


pigtails
Pigtails consist of a single outer jacket containing
six color-coded 900m fibers
One end of pigtail terminated to chosen
connector style and installed into the 6pak
plug-in adapters
TE recommends specific breakouts for panel
and wall mount box products

FL2000 6pak plug-in


with SC adapters and pigtails

Saves installation time

Ordering Information
Description

Catalog Number

OM3 6paks with 50/125 m Laser Optimized Multimode Pigtails


Multimode LC (aqua), with 5 meter 12 fiber OM3 stranded pigtails

FL2-6P6JC605R

Multimode SC (aqua), with 5 meter 6 fiber OM3 stranded pigtails

FL2-6P9JC605R

Multimode SC duplex (aqua), with 5 meter 6 fiber OM3 stranded pigtails

FL2-6PDJC605R

6paks - Singlemode Pigtails and adapters


LC UPC (blue), with 5 meter 12 fiber singlemode stranded pigtails

FL2-6P8SC605R

SC UPC (blue), with 5 meter 6 fiber singlemode stranded pigtails

FL2-6P7SC605R

ST UPC, with 5 meter 6 fiber singlemode stranded pigtails

FL2-6P4SC605R

10G 6paks utilize 50/125 m laser optimized multimode to 300 meters or OM3 rated glass and aqua
colored adapters.
Please note: Duplex SC adapters do not double the fiber count per adapter pack.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

307

Fiber Connectivity Solutions

102094AE

TrueNet Structured Cabling

Features

Fiber Connectivity Solutions


FL2000 System

Preconfigured Termination/Splice Panels, Black


10.14"
(25.76cm)

TrueNet Structured Cabling


102094AE

11`/11

Fiber Connectivity Solutions

Features
FL2000 panels can also be shipped with 6paks
and/or pigtails pre-installed at the factory.

19.60"
(49.79cm)

4.95"
(12.58cm)

5.25"
(13.34cm)

Reduce installation time


Simplify ordering process
Use this configuration guide to determine the
catalog number right for your application.

Catalog Number
FL2- C __ __ 0 __ __ __ __ __ __ __ __ __
2 3
4 5 6 7 8 9 10 11 12
Number
of Ports
Loaded

Nominal Capacity Panel Height


A

12 position

3.5" (8.89cm) (2RU)

24-position

5.25" (13.34cm) (3RU)

48 position

8.75" (22.23cm) (5RU)

72 position

14.00" (35.56cm) (8RU)

96 position

17.50" (44.45cm)
(10RU)

Connector Style

Number
of Splice
Decks

Pigtail or Adapter Type

Softwall bundle OM3


multimode 50/125
LOMMF 300m

Screwdriver

K1 Lock

k2 Lock

Softwall bundle

ST

6-fiber Maxi-Strip

LC

12-fiber Ribbon

12-fiber Maxistrip4

ST UPC

LC UPC

Singlemode Connectors

Mounting Style4
A

19"(8.26cm) Standard
(19.6" [49.78cm] overall)

19" (48.26cm) flush


Mount

Splice Type
1

None or N/A

Mechanical (Wheel)

Heat Shrink Fusion


(Wheel)

www.te.com/adc

Standard

SC UPC Duplex

Hole Plug

SC Duplex

SC UPC

2 Clamps

Adapters Only

SC

Singlemode Connectors

1 Clamp (Standard)

Latch Type

Multimode Connectors

Multimode Connectors

No. of Cable Clamps

+1-952-938-8080

LC connectors and adapters


double the capacity of the panel by
terminating two fibers at each adapter.
TE will automatically configure FL2000
panels with laser optimized cable to
use aqua colored SC or LC adapters
to indicate 10 Gigabit applications. To
order adapter only panels with aqua
colored adapters, purchase the empty
chassis and add 6paks separately.
Singlemode choices for use with LC
adapters, with multimode options TE
willautomatically choose best suited
fiber count.
Mounting kit shipped unattached if
other than standard mounting style.

1-800-366-3891

308

Fiber Connectivity Solutions


FL2000 System

Custom Preconfigured Termination/Splice Panels with


Two Adapter Styles, Black
10.14"
(25.76cm)

FL2000 panels can now be loaded with a combination of singlemode and multimode and/or
pigtails pre-installed at the factory.

4.95"
(12.58cm)

102094AE

5.25"
(13.34cm)

Panel available either horizontally or vertically loaded with like adapters with fully loaded
configurations
Reduces installation time
Simplify ordering process
Use this configuration to determine the catalog
number right for you.

Splice tray loading always follows loading style (vertical


or horizontal) i.e. the first two 6 packs' pigtails will be
routed to the top splice tray, the second two 6 packs'
pigtails will be routed to the 2nd down splice tray.

Catalog Number
FL2- __ __ __ __ 0 __ / __ __ - __ __ __ __
Panel Type
C
E

Nominal Capacity
A
B
D
E
F

No. of Cable Clamps


0 1 Clamp (Standard)
2 2 Clamps

Vertically Loaded (left/right)


Horizontally Loaded (top/bottom)

12-position
24-position
48-position
72-position
96-position

Panel Height

Latch Type
0 Standard
1 Hole Plug
2 Screwdriver
5 K1 Lock
6 k2 Lock

3.5" (2RU)
5.25" (3RU)
8.75" (5RU
14" (8RU)
17.50" (10RU)

1st, 2nd Connector Style

11/11

19.60"
(49.79cm)

Mounting Style
A 19" Standard (19.6" Overall)
C 19" Flush Mount

Multimode Connectors
9
SC
D
SC Duplex
5
ST
6
LC
Singlemode Connectors
7
SC UPC
E
SC UPC Duplex
4
ST UPC
8
LC UPC

No. of Spice Decks


0-8 Enter number of Splice
Decks Needed
Splice
0
W
2
3

1st, 2nd Pigtail or Adapter Type


A
Adapters Only
J
Softwall bundle OM3-50/125 300m
Horizontally loaded panel
1st conn style
1st adptr style
1st conn style
1st adptr style
2nd conn style 2nd adptr style
2nd conn style 2nd adptr style

www.te.com/adc

Vertically loaded panel


1st conn style 2nd adptr
1st conn style 2nd adptr
1st conn style 2nd adptr
1st conn style 2nd adptr

+1-952-938-8080

Type
None or N/A
HS Fusion (Wheel)
Heat Shrink Fusion (Deck)
Mechanical (Deck)

style
style
style
style

1-800-366-3891

309

Fiber Connectivity Solutions

TrueNet Structured Cabling

Features

Fiber Connectivity Solutions


FL2000 System

Mounting Options19" (48.26cm) Rack Mounting

TrueNet Structured Cabling

Panels typically shipped from factory equipped


for this mounting

17.50"
(44.45cm)

18.31"
(46.51cm)

21.88"
(55.58cm)

Panels shipped with


- Left-side L bracket
Standard Mount
Left-side 2.5" (6.32cm) wide vertical
(as shipped)
cable guide (VCg)

5.00"
(12.70cm)

5.00"
(12.70cm)

19.60"
(48.26cm)

Flush Mount

Rear Guard Box


(optional with some racks)

15.912"
(40.42cm)

17.50"
(44.45cm)

18.83"
(47.82cm)

5" (12.7 cm)


Recess Mounting Standard
Rack shown
as reference

1.94"
(4.93cm)

6.65"
(16.89cm)

FLUSH MOUNT

5.00"
(12.70cm)

5.00"
(12.70cm)

Ordering Information
Description
Flush mount
Allows 1", 2" or 4" (2.54, 5.08 or 10.16cm)
recess mounting
Kit includes: new vertical cable guide and
mounting flanges

102094AE

Rack shown
for reference

Rear Guard Box


(optional with some racks)

Features

Panel Height

Catalog Number

1.75" (4.45cm)
3.5" (8.89cm)
5.25" (13.34cm)
7" (17.78cm)
8.75" (22.23cm)
10.5" (26.67cm)

FL2-FLMT0175-B
FL2-FLMT0350-B
FL2-FLMT0525-B
FL2-FLMT0700-B
FL2-FLMT0875-B
FL2-FLMT1050-B

11`/11

Fiber Connectivity Solutions

Standard Mount (as shipped)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

310

Fiber Connectivity Solutions


FL2000 System

Mounting Options19" (48.26cm) Rack Maximum Mounting

5.00"
(12.70cm)

19.00
(48.26cm)
Rack shown
for reference

5.00"
(12.70cm)

2.93"

10.14"
(25.76cm)
4.95"
(12.58cm)

New VCG with integrated mounting holes

Ordering Information
Description
19" maximum, black
Allows entire panel to be contained
within frame footprint
Kit includes: new vertical cable guide with
integrated mounting holes

Panel Height

Catalog Number

1.75" (4.45cm)
3.5" (8.89cm)
5.25" (13.34cm)
7" (17.78cm)
8.75" (22.23cm)
10.5" (26.67cm)
14" (35.56cm)
17.5" (43.18cm)

FL2-19MAX0175-B
FL2-19MAX0350-B
FL2-19MAX0525-B
FL2-19MAX0700-B
FL2-19MAX0875-B
FL2-19MAX1050-B
FL2-19MAX1400-B
FL2-19MAX1750-B

11/11

102094AE

Mounting

17.50"
(44.45cm)

Rear Guard Box


(optional with some racks)

18.31"
(46.51cm)

Fiber Connectivity Solutions

9" Maximum

TrueNet Structured Cabling

21.88"
(55.58cm)

TSI Bracket
Mounting

20.276"
(51.50cm)

21.22"
(53.99cm)

21.88"
(55.58cm)

3.02"
(7.67cm)
5.00"
(12.70cm)
4.85"
(12.32cm)

www.te.com/adc

5.00"
(12.70cm)

+1-952-938-8080

1-800-366-3891

311

Fiber Connectivity Solutions

TrueNet Structured Cabling

TEs RMG Series offers a cost effective and highdensity rack mount fiber enclosure in one, two
and four rack unit sizes. Its modular design and
flexible configurations make it very user friendly
and easy to install.

Features
1 RU and 2 RU units contain sliding and removable front and rear access panels, providing convenient
access points
Designed for 48.26 cm (19-inch) EIA rack or cabinet environment; optional brackets to accommodate
58.42 cm (23-inch) rack or cabinet mounting
Density: up to 72 terminations in 1 RU
Low profile design with higher density for space limited applications
User friendly design utilizing industry standard LSX/LGX modular adapter packs
Side and rear cable entry points on back of panel supports a wide range of
deployment applications

Applications and Benefits


High-density makes suitable for telecommunications and equipment rooms
Can be cabinet mounted for data center applications

102094AE

TE introduces the RMG Series rack mount fiber


enclosures as an integral part of the TrueNet
product portfolio. TEs RMG Series fiber enclosure
provides rugged and durable protection for
patching or splicing of fiber cables. Especially
designed to be user friendly, the slide-out design
and removable front and rear panels provide
convenient access points.

11`/11

Fiber Connectivity Solutions

RMG Series Fiber Enclosures

www.te.com/adc

+1-952-938-8080

1-800-366-3891

312

Fiber Connectivity Solutions


RMG Series Fiber Enclosures

Recommended
Applications

Multi-purpose high density modular solution ideal for telecommunications


closets or to terminate incoming fiber trunks

Description

Termination, termination/splice

Chassis sizes
(in rack units)

1, 2, and 4

Termination only
capacity using:
Simplex adapters 18, 36, 72
Duplex adapters 36, 72, 144 (includes standard LC)
Small form factor (LC) 72, 144, 288 (using quad LC)
Ideal for growth

Interconnect

Yes

Cross-connect

No

Accommodates
on-frame splicing

Yes. Built-in

Rear access

Yes

All-front-access

Yes

Customer premises
application

Ideal

19" mounting

Yes

23" mounting

Yes, with separate extender bracket

Cabinet mount

Yes

Wall mount

No

Mix equipment with


fiber product?

Ideal

Vertical cable guide

No

Features at a Glance

Limited cable management, high density with features and price comparable to
traditional LgX style panels.

Fiber Connectivity Solutions

Flexibility/
ablity to grow

11/11

102094AE

TrueNet Structured Cabling

Product Overview

www.te.com/adc

+1-952-938-8080

1-800-366-3891

313

Fiber Connectivity Solutions


Rack Mount Fiber Enclosures

-40 C to 85 C (-40 F to 185 F)


5.44 kg (12 lbs)
5.90 kg (13 lbs)
6.80 kg (15 lbs)

72 terminations
144 terminations
288 terminations
36 terminations
72 terminations
144 terminations

Maximum density achieved using quad LC connectors.

1 RU, 2 RU and 4 RU

102094AE

TrueNet Structured Cabling

Storage/operating temperature:
Approximate weight (empty panel)
1 RU model:
2 RU model:
4 RU model:
Configuration options and capacity
Termination only
1 RU maximum density1:
2 RU maximum density1:
4 RU maximum density1:
Termination/splice
1 RU maximum density:
2 RU maximum density:
4 RU maximum density:

12.70 cm
(5.00")

42.77 cm
(16.84")

11`/11

Fiber Connectivity Solutions

Specifications

www.te.com/adc

+1-952-938-8080

1-800-366-3891

314

Fiber Connectivity Solutions


RMG Series Fiber Enclosures
1 RU Model

46.51 cm
(18.31")
48.26 cm
(19.00")

35.48 cm
(13.97")

2 RU Model

3.17 cm (1.25") 8.81 cm (3.47")

Fiber Connectivity Solutions

46.51 cm
(18.31")
48.26 cm
(19.00")

35.48 cm
(13.97")

4 RU Model

5.08 cm (2.00") 10.16 cm (4.00") 17.53 cm (6.90")

46.51 cm
(18.31")
48.26 cm
(19.00")

11/11

102094AE

TrueNet Structured Cabling

3.17 cm (1.25") 4.37 cm (1.72")

35.48 cm
(13.97")

www.te.com/adc

+1-952-938-8080

1-800-366-3891

315

Fiber Connectivity Solutions


RMG Series Fiber Enclosures
RMG Empty Panels

TrueNet Structured Cabling

Features
Mounting options:
Shipped with standard 48.26 cm (19-inch) EIA rack or cabinet mounting hardware
Optional brackets to accommodate 58.42 cm (23-inch) EIA rack or cabinet mounting
Ability to quickly and easily configure, utilizing the modular adapter pack

Ordering Information
Description

Panel Height

Catalog Number

1 RU empty panel; accommodates 3 modular adapter packs;


black

4.45 cm (1.75")

RMG-1000-000B

2 RU empty panel; accommodates 6 modular adapter packs;


black

8.89 cm (3.50")

RMG-2000-000B

4 RU empty panel; accommodates 12 adapter packs;


also includes cable management bracket and cable clamp;
black

17.78 cm (7.00")

RMG-4000-000B

Rack or Cabinet Mount Panel, black

Accessories
Cable Clamp Kit (for 1 RU and 2RU)

RMG-ACC001

Blank Plates

RMG-00ADP00

Heat shrink fusion

FST-DV-HS

Mechanical

FST-DV-MT

Extender Brackets; 48.26 cm (19" - 23")


1 RU

EB-17B

2 RU

EB-35B

Q-Frame 4 RU Mounting Bracket

RMG-ACCQBRkT4RU

102094AE

Splice Tray

11`/11

Fiber Connectivity Solutions

The RMG empty panel with blank panels includes 48.26 cm (19-inch) EIA mounting brackets and
hardware, polycarbonate front door, cable ties, cable management rings and circuit identification cards.
The RMg empty panel allows for the user to mix and match any combination of modular adapter packs
or simply utilize a grow as you go approach to their network.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

316

Fiber Connectivity Solutions


RMG Series Fiber Enclosures
RMG Standard Adapter Packs

TrueNet Structured Cabling

The RMg Series offers a variety of standard modular adapter packs to accommodate most applications.
They utilize the industry standard LSX/LgX footprint and are readily available.

Ordering Information
Description

Catalog Number

LC quad adapters, beige color


6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ3

LC adapters, beige color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ1

SC duplex adapters, beige color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC3

SC adapters, beige color


6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC1

ST adapters
6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT1

102094AE

OM3/OM4 multimode adapter only packs1


LC quad adapters, aqua color
6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ4

LC adapters, aqua color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ2

SC duplex adapters, aqua color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC4

SC adapters, aqua color


6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC2

11/11

Singlemode (UPC) adapter only packs


LC UPC quad adapters, blue color
6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ8

LC UPC quad adapters, blue color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ5

SC UPC duplex adapters, blue color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC8

SC UPC adapters, blue color


6 adapters or 6 fiber ports per adapter pack

RMG-12ADPC7

ST UPC adapters
6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT2

TE recommends the use of aqua colored adapters with laser-optimized multimode fiber for 10 Gigabit applications
for circuit identification.
1

www.te.com/adc

+1-952-938-8080

1-800-366-3891

317

Fiber Connectivity Solutions

OM1/OM2 Multimode adapter only packs

Fiber Connectivity Solutions


RMG Series Fiber Enclosures

Features
Can be ordered with all standard types of simplex and duplex multimode and
singlemode adapters
Available with preterminated 3 m (9.84 ft) pigtails to reduce installation time and cost
One end of pigtail terminated to chosen connector style and installed into adapter pack
plug-in adapters

Catalog Number
RMG-__ ADP__ __ __ __
Number of Adapters
06

6 simplex adapters

12

6 duplex adapters

24

6 quad adapters

Pigtail Length
LEAVE
BLANk

03

Connector Style

Adapters only
3 meter pigtails

Pigtail Type

Multimode Connectors

102094AE

TrueNet Structured Cabling

TEs RMG modular adapter pack assemblies can be used in any of the RMG series fiber enclosures in a
variety of connector styles and with or without preterminated 3 m (9.84 ft) pigtails. Its modular design
is user friendly and easy to install. Use the following matrix to configure the correct catalog number for
the application. If the resulting catalog number is not on the standard list, the product is considered
custom and may have longer lead times.

LEAVE
BLANk

Adapters only

C1

SC

C2

SC (aqua)2

Singlemode stranded

Multimode stranded

C3

SC duplex

C4

SC duplex (aqua)2

Q1

LC1

Q2

LC (aqua)1, 2

Q3

Quad LC

OM1 62.5/125 Multimode

Q4

Quad LC (aqua)2

OM3 50/125 LOMMF 300 m

T1

ST

Singlemode

Fiber Size
LEAVE
BLANk

Adapters only

Singlemode Connectors

11`/11

Fiber Connectivity Solutions

Custom Modular Adapter Packs

1
2

C7

SC UPC

C8

SC UPC duplex

Q5

LC UPC1

Q8

LC UPC quad

T2

ST UPC

LC adapters terminate two fibers at each adapter and should be considered duplex adapters in this ordering scheme
TE recommends the use of aqua colored adapters with laser optimized multimode fiber applications for 10 Gigabit
circuit identification.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

318

Fiber Connectivity Solutions


RMG Series Fiber Enclosures

RMG Pre-configured Panels with Adapters only or with Pigtails

Catalog Number
RMG-__ __ __ - __ __ B
Panel Size
1 RU (1.75")

3 adapter packs

2 RU (3.50")

6 adapter packs

4 RU (7.00")

12 adapter packs

Splice Deck Type

Panel Size

None

Heat shrink fusion

Mechanical fusion

Adapters only

Adapters and singlemode


stranded pigtails

Adapters and stranded pigtails OM3


50/125 LOMMF 300m1

03
06

6 adapter packs, loaded

Adapters and stranded OM1


62.5/125 multimode pigtails

12

12 adapter packs, loaded

Loaded Adapter Paks


3 adapter packs, loaded

Fiber Connectivity Solutions

Adapters/Pigtails
Multimode Connectors

102094AE

TrueNet Structured Cabling

TEs RMG series fiber panels are available to be shipped with factory installed adapter modules
and/or preterminated pigtail assemblies which simplifies the ordering process and reduces installation
time and costs. These configurations are custom and build-to-order.

C1

SC

C2

SC (aqua)1

C3

SC duplex

C4

SC duplex (aqua)1

Q1

LC

Q2

LC (aqua)1

Q3

LC quad

Q4

LC quad (aqua)1

T1

ST

11/11

Singlemode Connectors
C7

SC UPC

C8

SC UPC duplex

Q5

LC UPC

Q8

LC UPC quad

T2

ST UPC

TE recommends the use of aqua colored adapters with laser optimized multimode fiber applications for 10 Gigabit
circuit identification.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

319

Fiber Connectivity Solutions


FL1000

Recent improvements to labeling grommets, door latches and ribbon pigtail routing reinforce the value
these products bring to the physical layer of any network with higher quality and reliability, greater
operational efficiencies and network simplification.

Product Overview
Ideal for small to medium fiber counts within communication closets or
demarcation points

Description

One or two door wall box solution offering excellent fiber protection and
technician-friendly cable routing. Termination or termination/splice
boxes available

102094AE

Recommended
Applications

Flexibility/
ability to grow

Modular growth design

Demarcation

Yes

TrueNet Structured Cabling

TEs FL1000 customer premises fiber termination products include a variety of one and two door wall
mount panels. These products are designed specifically to act as part of the fiber distribution system as
the demarcation point for the service provider at the customers location.

Termination only
capacity using:
Simplex adapters
Duplex adapters
Small form factor (LC)

Accommodates
in box splicing

Yes. Built-in

All-front-access

Yes

Customer premises
application

Ideal

Wall mount

Yes

11`/11

Fiber Connectivity Solutions

Introduction

www.te.com/adc

12, 24, 48, 72


12, 24, 48, 72
24, 48, 96, 144

+1-952-938-8080

1-800-366-3891

320

Fiber Connectivity Solutions


FL1000

Wall Mount Boxes (One Door)


Features

Ability to accept locks


Acceptance of cable clamps at each corner
Grounding screws, mounting screws and
dust caps are included with each panel.
More accessories are available on page 84
Wall Box
(One Door)

12-Position Termination/Splice Wall Box


305 mm
(12")
91 mm
(3.6")

Fiber Connectivity Solutions

TrueNet Structured Cabling

Numerous cable tie points within the boxes

330 mm
(13")

259 mm
(10.2")

102094AE

24-Position Termination/Splice Wall Box


330 mm
(13")

91 mm
(3.6")

11/11

356 mm
(14")

381 mm
(15")

See ordering information on following page.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

321

Fiber Connectivity Solutions


FL1000

One Door Wall Mount Chassis


Allows single door access.
330 mm
(13")

381 mm
(15")

86 mm
(3.4")

91 mm
(3.6")

12-Position Termination/Splice
One Door Wall Box
FL1-A

24-Position Termination/Splice
One Door Wall Box
FL1-B

Ordering Information
Description

Catalog Number

Empty termination/splice chassis


12-position
24-position

FL1-A
FL1-B

102094AE

TrueNet Structured Cabling

279 mm
(11")

11`/11

Fiber Connectivity Solutions

310 mm
(12.2")

All empty chassis use TE FL1000 and FL2000 6pak adapters.


Please see pages 7071 and 8384 for ordering information.
www.te.com/adc

+1-952-938-8080

1-800-366-3891

322

Fiber Connectivity Solutions


FL1000

Two Door Wall Mount Chassis


Allows separate customer and provider access.
437 mm
(17.2")

452 mm
(17.8")

381 mm
(15")

158 mm
(6.2")

99 mm
(3.9")

24-Position Termination/Splice
Two Door Wall Box
FL1-H

48-Position Termination/Splice
Two Door Wall Box
FL1-J

Fiber Connectivity Solutions

483 mm
(19")

546 mm
(21.5")

152 mm
(6")

72-Position Termination/Splice
Two Door Wall Box
FL1-P

Ordering Information
Description

Catalog Number

Empty termination/splice chassis


12-position
24-position
48-position
72-position

FL1-g
FL1-H
FL1-J
FL1-P

11/11

102094AE

TrueNet Structured Cabling

361 mm
(14.2")

www.te.com/adc

+1-952-938-8080

1-800-366-3891

323

Fiber Connectivity Solutions


FL1000

6pak Connector Plug-Ins and Accessories

TrueNet Structured Cabling


102094AE

11`/11

Fiber Connectivity Solutions

Features
Completely interchangeable between FL2000
panel and wall box products
6pak plug-in (shown with
singlemode duplex adapters)

Can be ordered with all standard types


of simplex and duplex single and multimode
adapters and connectors
Feature TEs patented removable
angled retainers which provide superior
fiber management
No tools required to install into FL2000
boxes or panels

6pak plug-in (shown with


multimode duplex adapters)

Ordering Information
Catalog Number

Description
6pak Connector Plug-Ins
Multimode
SC
SC (aqua)
ST
SC (duplex)
SC (aqua, duplex)
LC
LC (aqua)

FL2-6PMMSC
FL2-6PMMSC-A
FL2-6PMMST
FL2-6PMMDSC
FL2-6PMMDSC-A
FL2-6PMMLC
FL2-6PMMLC-A

Singlemode
SC
ST
SC (duplex)
LC

FL2-6PSMSC
FL2-6PSMST
FL2-6PSMDSC
FL2-6PSMLC

6pak blank plug-in

FL2-6PBLNk

6pak blank plug-in

6pak plug-in (shown with


singlemode simplex adapters)

FL1000 Accessories
Compression fitting

FL1-ACC001

Compression fitting
with plate

FL1-ACC006

Strength member tie-off kit

FL1-ACC003

Cable clamp
Bonding grounding kit
Lock and key type A
Lock and key type B

FL1-ACC011
FL1-ACC004
IPA-K1
IPA-k2

Mini-splice tray
(used only in 12-position,
wall-mount box)
Heat shrink (single fiber fusion)
Mechanical (mass fusion)

FST-M-HS
FST-M-MT

Standard splice tray


Heat shrink (single fiber fusion)
Mechanical (mass fusion)

FST-HS
FST-MT

www.te.com/adc

+1-952-938-8080

6pak plug-in (shown with


multimode simplex adapters)

6pak Adapter-Only
(Without Fiber)

1-800-366-3891

324

Fiber Connectivity Solutions


FL1000

6pak Adapter Adapters and Pigtails


Features

TrueNet Structured Cabling

Can be purchased and installed as


growth necessitates
Available with preterminated three-meter
pigtails
Pigtails consist of a single outer jacket
containing six color-coded 900 m fibers
One end of pigtail terminated with chosen
connector style and installed into the
6pak adapter

6pak Adapter
(With SC Adapters and Pigtails)

Saves installation time

Description

Catalog Number

OM3 6paks with 50/125 m Laser Optimized Multimode Pigtails

10G Multimode LC (aqua), with 5 meter 12 fiber OM3 stranded pigtails

FL2-6P6JC605R

10G Multimode SC (aqua), with 5 meter 6 fiber OM3 stranded pigtails

FL2-6P9JC605R

10G Multimode SC duplex (aqua), with 5 meter 6 fiber OM3 stranded pigtails

FL2-6PDJC605R

6paks - Singlemode Pigtails and adapters


LC UPC (blue), with 5 meter 12 fiber singlemode stranded pigtails

FL2-6P8SC605R

SC UPC (blue), with 5 meter 6 fiber singlemode stranded pigtails

FL2-6P7SC605R

ST UPC, with 5 meter 6 fiber singlemode stranded pigtails

FL2-6P4SC605R

10G 6paks utilize 50/125 m laser optimized multimode to 300 meters or OM3 rated glass and aqua
colored adapters.
Please note: Duplex SC adapters do not double the fiber count per adapter pack.

11/11

102094AE

Other configurations are available upon request. Please contact TE Technical Assistance Center.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

325

Fiber Connectivity Solutions

Ordering Information

Fiber Connectivity Solutions

Features
Superior cable management through the use of bend radius control at all cable exits and
strain relief protection
Optional integrated splice module on the 4 and 8 module panel version
Available pre-loaded with any industry-standard adapter
Added security protection
6-position or 8-position modular adapter panel capability
Compact design
Fully enclosed and lockable
Wrap-around client-side door design (WMG-8000-00B) provides maximum adapter accessibility
for client-side patching
Multi-sized cable entry knockouts (WMG-8000-00B) supports either -inch or -inch cable
glands for maximum cable strain relief and protection

Product Overview
Ideal for small to medium fiber counts within communication
closets or demarcation points.
Two door wall box solution utilizing standard LSX/LgX footprint modular adapter
packs. Standard boxes accommodate both termination and termination/splice
applications.

102094AE

Recommended
Applications
Description

TrueNet Structured Cabling

The WMG Series Wall Mount Fiber Enclosures


are ideal for LAN applications requiring
a fully enclosed and lockable wall mount
enclosure. The cabinets are one or two-door
direct termination and splice solutions. These
enclosures are designed to support up to eight
modular adapter packs. This rugged wall-mount
cabinet is equipped with cable management
modules and cable routing accessories to limit
bend radius and add strain relief control.

Flexibility/
ablity to grow

Modular growth design

Demarcation

Yes

Accommodates
in box splicing

Yes. Built-in

All-front-access

Yes

Customer premises
application

Ideal

Wall mount

Yes

Termination only
capacity using:
Simplex adapters 12, 24, 721
Duplex adapters 24, 48, 96 (including standard LC adapters)
Small form factor (LC) 48, 96, 192 (utilizing quad LC adapters)

11`/11

Fiber Connectivity Solutions

WMG Series Wall Mount Fiber Enclosures

Splicing can be only accommodated at the simplex adapter capacity, regardless of adapter used.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

326

Fiber Connectivity Solutions


WMG Series Wall Mount Fiber Enclosures
WMG Empty Wall Box

Features
Available in three sizes to suit a variety of applications and fiber counts
Standard LSX/LGX adapter pack footprints are accommodated in empty wallbox

Description
Empty Wall boxMaximum capacity 2 adapter packs
Empty Wall boxMaximum capacity 4 adapter packs
Empty Wall boxMaximum capacity 8 adapter packs

Dimensions

Catalog Number

9" x 12" x 3.5"


12" x 15" x 3.5"
14" x 17.25" x 7"

WMG-2000-00B
WMG-4000-00B
WMG-8000-00B

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

327

Fiber Connectivity Solutions

Ordering Information

102094AE

TrueNet Structured Cabling

The WMg empty wall box allows for the user


to mix and match any combination of modular
adapter packs or simply utilize a grow as you
go approach to their network.

Fiber Connectivity Solutions


WMG Series Wall Mount Fiber Enclosures

Features
Completely interchangeable between RMG & WMG fiber enclosures
Can be ordered with all standard types of simplex & duplex multimode and singlemode adapters
Available with preterminated 3m (9.84') pigtails to reduce installation time & cost
One end of pigtail terminated to chosen connector style and installed into adapter pack plug-in adapters

Ordering information follows on the next page

102094AE

TrueNet Structured Cabling

TEs RMG modular adapter pack assemblies


can be used in any of the RMg or WMg series
fiber enclosures in a variety of connector styles
and with or without preterminated 3m (9.84')
pigtails. Its modular design is user-friendly and
easy to install. The RMg Series modular adapter
packs are not interchangeable with FL2000 or
FL1000 Series fiber enclosures.

11`/11

Fiber Connectivity Solutions

Modular Adapter Packs

www.te.com/adc

+1-952-938-8080

1-800-366-3891

328

Fiber Connectivity Solutions


WMG Series Rack Mount Fiber Enclosures
WMG Standard Adapter Packs

TrueNet Structured Cabling

The WMg Series offers a variety of standard modular adapter packs to accommodate most applications.
They utilize the industry standard LSX/LgX footprint and are readily available.

Ordering Information
Description

Catalog Number

LC quad adapters, beige color


6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ3

LC adapters, beige color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ1

SC duplex adapters, beige color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC3

SC adapters, beige color


6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC1

ST adapters
6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT1

102094AE

OM3/OM4 multimode adapter only packs1


LC quad adapters with zirconia sleeve, aqua color
6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ4

LC adapters with zirconia sleeve, aqua color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ2

SC duplex adapters with zirconia sleeve, aqua color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC4

SC adapters with zirconia sleeve, aqua color


6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC2

11/11

Singlemode (UPC) adapter only packs


LC quad adapters, blue color
6 adapters or 24 fiber ports per adapter pack

RMG-24ADPQ8

LC quad adapters, blue color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPQ5

SC duplex adapters, blue color


6 adapters or 12 fiber ports per adapter pack

RMG-12ADPC8

SC adapters, blue color


6 adapters or 6 fiber ports per adapter pack

RMG-06ADPC7

ST adapters
6 adapters or 6 fiber ports per adapter pack

RMG-06ADPT2

TE recommends the use of aqua colored adapters with laser-optimized multimode fiber for 10 Gigabit applications
for circuit identification.
1

www.te.com/adc

+1-952-938-8080

1-800-366-3891

329

Fiber Connectivity Solutions

OM1/OM2 Multimode adapter only packs

Fiber Connectivity Solutions


WMG Series Rack Mount Fiber Enclosures
Custom Modular Adapter Packs

Can be ordered with all standard types of simplex and duplex multimode and
singlemode adapters
Available with preterminated 3 m (9.84 ft) pigtails to reduce installation time and cost
One end of pigtail terminated to chosen connector style and installed into adapter pack
plug-in adapters

Catalog Number
RMG-__ ADP__ __ __ __
Number of Adapters
06

6 simplex adapters

12

6 duplex adapters

24

6 quad adapters

Pigtail Length
LEAVE
BLANk

03

Connector Style

Adapters only
3 meter pigtails

Pigtail Type

Multimode Connectors

102094AE

TrueNet Structured Cabling

Completely interchangeable between WMG panel products

LEAVE
BLANk

C1

SC

C2

SC (aqua) with zirconia sleeve

C3

SC duplex

C4

SC duplex (aqua) with zirconia sleeve

Q1

LC1

Q2

LC (aqua)1, 2

Adapters only

Singlemode stranded

Multimode stranded

Fiber Size
LEAVE
BLANk

Adapters only

Q3

Quad LC

Q4

Quad LC (aqua)2

OM3 50/125 LOMMF 300 m

T1

ST

Singlemode

OM1 62/125

C5

SC UPC

C6

SC UPC duplex

Q5

LC UPC1

Singlemode Connectors

Q8

LC UPC quad

11`/11

Fiber Connectivity Solutions

Features

T2

ST UPC

1
2

LC adapters terminate two fibers at each adapter and should be considered duplex adapters in this ordering scheme
TE recommends the use of aqua adapters with multimode Ultra fiber to visually identify 10 Gigabit circuits

www.te.com/adc

+1-952-938-8080

1-800-366-3891

330

Fiber Connectivity Solutions


Fiber Optic Specifications

Singlemode Ultra
Polish Connectors (UPC)
Insertion Loss
(1310 and 1550 nm)
Return Loss
(1310 and 1550 nm)
Fiber Recess
Apex Offset
Radius of Curvature
Multimode Ultra
Polish Connectors
Insertion Loss
(1300 nm)
Return Loss
(1300 nm)

SC
0.2 dB max.
0.09 dB typical
-57 dB min.

LC
0.3 dB max.
0.1 dB typical
-55 dB min.

50 nm
50 m max.
10-25 mm

-100 to +50 nm
50 m max.
10-25 mm

SC
0.3 dB max.

LC
0.3 dB max.

-20 dB min.

-20 dB max.

Every patch cord manufactured by TE is designed to pass rigorous qualification testing that includes: EIA/
TIA Industry Standards according to Fiber Optic Test Procedures (FOTP).
Item Specifications

EIA/TIA Test

Item Specifications

EIA/TIA Test

Temperature shock
Humidity
Temperature life
Mating durability
Vibration

FOTP-3
FOTP-5
FOTP-4
FOTP-21
FOTP-11

Cable flex
Cable retention
Cable twist
Impact

FOTP-1A
FOTP-6
FOTP-36
FOTP-2

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

331

Fiber Connectivity Solutions

Mechanical and Environmental Characteristics

102094AE

TrueNet Structured Cabling

Optical Performance

Fiber Connectivity Solutions


Fiber Optic Specifications
Patch Cords
Length
1 to 15 m
+15 m

44 mm
(2.1")
5.6 mm
(.22")

LC 2.0 mm Connector

53 mm
(2.08")
7.4 mm
(.29")

SC 2.0 mm Connector

102094AE

TrueNet Structured Cabling

Connector Dimensions

11`/11

Fiber Connectivity Solutions

Assembly Length

Tolerance
+16 cm/-0 cm
+1%/-0 cm

www.te.com/adc

+1-952-938-8080

1-800-366-3891

332

Fiber Connectivity Solutions

As an integral part of the TrueNet Fiber


Connectivity product portfolio, TrueNet fiber
optic patch cords are essential to meet the
requirements of todays high-speed data
networks. These patch cords can be used
throughout the network in cross-connect, test
or equipment areas to link optical equipment
and are backed by the TrueNet Zero-Bit Error
Warranty.

Features

Lead-free OFNP jacket and RoHS compliant


All patch cords are shipped with insertion loss tests for individual cords
Readily available in LC-LC, LC-SC, and SC-LC configurations in standard lengths of 1, 2, 3, 5, 7, 10, and
15 meters.
Available in singlemode and OM1, OM2, OM3, OM4 multimode glass types
ANSI/TIA 568-C compliant

Specifications
Operating Temperature Range:
Intermatability Standard:
Insertion Loss:
Reflectance:

32 to 158 F (0 to 70 C)
TIA/EIA 604-10 (FOCIS 10)
0.10 typical, 0.30 maximum
<-20 dB (MM)

All patch cords undergo testing for insertion loss, return loss and reflectance at the factory before shipment
to ensure that only quality product is delivered to the customer.

Optical Performance

11/11

SC

LC

Singlemode Ultra Polish Connectors (UPC)


Insertion Loss
(1310 and 1550 nm)

0.2 dB max
0.09 dB typical

0.3 dB max.
0.1 dB typical

Return Loss
(1310 and 1550 nm)

-57 dB min.

-55 dB min.

0.3 dB Max
0.1 dB typical

0.3 dB Max
0.1 dB typical

Multimode Connectors
Insertion Loss
(850 and 1300 nm)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

333

Fiber Connectivity Solutions

LC and SC duplex connectors are equipped with a removable duplex clip for simple Tx/Rx reconfiguration
in the field.

102094AE

TrueNet Structured Cabling

Fiber Optic Patch Cords

Fiber Connectivity Solutions


Fiber Optic Patch Cords

Ordering Information

TrueNet Structured Cabling

2mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P10CxxxM

2mm zipcord LC-SC connectors (with duplex clips)

PAT-LCSC-P10CxxxM

2mm zipcord SC-SC connectors (with duplex clips)

PAT-SCSC-P10CxxxM

OM2 - 50/125 multimode; OFNP jacket


2mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P20CxxxM

2mm zipcord LC-SC connectors (with duplex clips)

PAT-LCSC-P20CxxxM

2mm zipcord SC-SC connectors (with duplex clips)

PAT-SCSC-P20CxxxM

1.6mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P20AxxxM

OM3 -50/125 LOMMF 300 meters; OFNP jacket


2mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P30CxxxM

2mm zipcord LC-SC connectors (with duplex clips)

PAT-LCSC-P30CxxxM

2mm zipcord SC-SC connectors (with duplex clips)

PAT-SCSC-P30CxxxM

1.6mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P30AxxxM

OM4 -50/125 LOMMF 550 meters; OFNP jacket


2mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P40CxxxM

2mm zipcord LC-SC connectors (with duplex clips)

PAT-LCSC-P40CxxxM

2mm zipcord SC-SC connectors (with duplex clips)

PAT-SCSC-P40CxxxM

1.6mm zipcord LC-LC connectors (with duplex clips)

PAT-LCLC-P40AxxxM

Singlemode; OFNP jacket


2mm zipcord LC UPC-LC UPC connectors (with duplex clips)

PAT-LCLC-PS0CxxxM

2mm zipcord LC UPC-SC UPC connectors (with duplex clips)

PAT-LCSC-PS0CxxxM

2mm zipcord SC UPC-SC UPC connectors (with duplex clips)

PAT-SCSC-PS0CxxxM

1.6mm zipcord LC UPC-LC UPC connectors (with duplex clips)

PAT-LCLC-PS0AxxxM

xxx = length in meters: 001 = 1.0m, 002 = 2.0m, 003 = 3.0m, 005 = 5.0m, 006 = 6.0m, 007 = 7.0m, 010 = 10.0m,
015 = 15.0m
Contact TE Connectivity for availability of custom lengths.

102094AE

Catalog Number1

OM1 - 62.5/125 multimode; OFNP jacket

11`/11

Fiber Connectivity Solutions

Product Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

334

Fiber Connectivity Solutions


Fiber Optic Connectors
Features
Available in both singlemode and multimode
constructions
Connectors utilize pre-radiused zirconia
ceramic ferrules
Singlemode ultra physical contact (UPC)
available for SC, and LC connectors
SC and LC connectors can be duplexed
ST, SC, and LC tested to rigid Telcordia
GR-326 standard
Available for 900m installations
Typical insertion loss: 0.2dB

TEs TrueNet Fiber Optic Connectors are essential to meet the requirements of todays high-speed data
networks. TE offers a wide array of fiber optic connectors as well as a variety of products that field
installers can use to terminate multi fiber cable. The following information will outline the solutions
along with the ordering information technicians will need to conduct field terminations.
Connectors are available for both singlemode and multimode applications and in the following
connector types:
SC: All plastic components; "Snap Click" connections; screw on feature with key alignment
ST: All metal components; not "pull proof"
LC: Constructed with a plastic housing and provide for accurate alignment via their ceramic ferrules.
TE also offers a comprehensive group of kits and accessories needed for termination. The Epoxy/Polish,
Ideal and consumables kits contain all the tools necessary to terminate your specified connector. Also, a
complete fiber connector/adapter cleaning kit is available.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

335

Fiber Connectivity Solutions

All styles meet Fiber Optic Connector


Intermateability Standard (FOCIS) documents

102094AE

TrueNet Structured Cabling

ST, SC, and LC connector types available

Fiber Connectivity Solutions


Fiber Optic Connectors

SC/ST Typical Specifications


Insertion Loss
Singemode & Multimode:

0.5 dB maximum
0.2 dB typical
1000 mates,
less than 0.2 dB change
-55 to +85 C
-40 to +75 C

TrueNet Structured Cabling

ENVIRONMENTAL
Vibration, Impact, Thermal, Humidity:

Tested to GR-326

LC Typical Specifications
Return Loss:
Insertion Loss:
Operating Temperature:
Lifetime:
Cable Diameter:
Tensile Strength:

> 20 dB > 50 dB > 60 dB


0.5 dB maximum; 0.2 dB typical
-40 to +75 degrees C (depending on cable type)
1000 cycles
Buffered Fiber: 900 m
Buffered Fiber: 5 N

Epoxy/Polish Connectors
Ordering Information
Description

Catalog Number

SC epoxy/polish connector
Singlemode, 900m blue boot, ceramic ferrule
Multimode, 900m black boot, ceramic ferrule

EPSCUSM30096BL
EPSCXMM30096Bk

ST epoxy/polish connector
Singlemode, 900m yellow boot, ceramic ferrule
Multimode, 900m black boot, ceramic ferrule

EPSTUSM30096YL
EPSTXMM30096Bk

LC epoxy/polish connector
Singlemode, 900m boot, ceramic ferrule
Multimode, 900m boot, ceramic ferrule
LC duplex clip

EPLCUSM30095
EPLCXMM30095
LCD-CLIP

102094AE

Storage Temperature:
Operating Temperature:

11`/11

Fiber Connectivity Solutions

Durability:

www.te.com/adc

+1-952-938-8080

1-800-366-3891

336

Fiber Connectivity Solutions


Accessories

Epoxy/polish Connector Tool kits and Ideal Tool kits are provided with a list of contents and instructions
for use. The latest connector designs demand the proper strip length, epoxy application and crimp size
for the connector to perform properly. Both tool kits contain a Universal Crimp Tool.
Both the Epoxy/polish Connector and Ideal Toolkits include the following:
Alcohol

9"X13" Polish Plate

Shrink Tape

5 Packs of Epoxy

Micro Torch

5 (9"X13") 5m Polish Film

Kim Wipes

5 (9"X13") 1m Polish Film

Canned Air

10 (9"X13") .3m Polish Film

Jacket Stripper

Cable Ties

Shrink Tubes

2 Storage Boxes

Epoxy Mixer

50 Pack Foam Swabs

Workmat

Economy Pen Scribe

Cable Markers

Red No-Nik

Utility knife

Matching gel

Tweezers

Scissors

100X Microscope With


Adapter

Buffer Tube Stripper

Universal Fiber Continuity


Tester
Universal Crimp Tool
Fusion Splice Sleeves (Clear)
4 Bit Screwdriver
Syringes (5)
Measuring Tape
Connector Cleaner
Miller Stripping Tool
Piano Wire

Fiber Connectivity Solutions

102094AE

TrueNet Structured Cabling

TE TrueNet's field termination tool kits contain all the necessary tools to terminate the specified
connector. Consumable items will complete approximately 50 connectors and may be ordered separately
as a consumable kit. Connector ovens may also be ordered separately. International and air shipments
exclude alcohol and canned air.

Permanent Black Marker

Also included in the following toolkits specifically:


Epoxy/Polish Kit:
Specify type of connector for Polish Disc, see ordering information
Ideal Kit:
Contains curing oven with thermometer
Contains Polishing Disks for ST, SC, FC connectors
Ordering Information
Description

Catalog Number

Toolkits

11/11

Epoxy/Polish
SC: Epoxy/polish connector tool kit, enough consumables for 50 connectors
(1 per technician)

EPTk-SC

ST: Epoxy/polish connector tool kit, enough consumables for 50 connectors


(1 per technician)

EPTk-ST

LC: Epoxy/polish connector tool kit, enough consumables for 50 connectors


(1 per technician)

EPTk-LC

Ideal Tool Kit


Ideal Tool kit, enough consumables for 50 connectors (1 per technician)

IDTK

LC polishing disk for use with Ideal tool kit

EPLC-PUCk

www.te.com/adc

+1-952-938-8080

1-800-366-3891

337

Fiber Connectivity Solutions


Accessories

TE TrueNet's field termination consumables kits contain all of the consumables necessary to terminate
any TE connector. International and air shipments exclude alcohol and canned air.

(9"X13") 3 in one polishing paper (50)

Syringes (10)

5m gray Section

Mini foam swabs (100)

1m green Section

Alcohol (8 oz.)

0.3m White Section

Kimwipes (2 boxes)

Packs of Epoxy (10)

Canned Air (2 cans)

Ordering Information
Description

Catalog Number

Accessories
Consumables
Consumables for epoxy/polish connectors (1 per 100 connectors)

EPTk-CON

Loctite Primer
Anaerobic Primer, Loctite 7649 (enough for approximately 500 connectors)

EP-LOC7649

Loctite Adhesive
Anaerobic Adhesive, Loctite 680 (enough for approximately 500 connectors)

EP-LOC680

102094AE

TrueNet Structured Cabling

Kit includes:

11`/11

Fiber Connectivity Solutions

Consumables kits are provided with a list of contents and instructions for use. The latest connector
designs demand the proper strip length, epoxy application and crimp size for the connector to
perform properly.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

338

Fiber Connectivity Solutions


Accessories

The fiber connector/adapter cleaning kit contains


all the items required to adequately clean fiber
connectors and adapters. The performance of an
optical fiber system is largely dependent on the
fiber connector cleaning procedures followed prior
to installation. It is suggested that all the connectors
and adapters be cleaned before making any
connections. The kit cleans approximately 500
connectors or adapters.

Ordering Information
Catalog Number

Fiber connector/adapter cleaning kit


Includes:
Instruction sheet
Lint-free wipes
Isopropyl alcohol
Cotton swabs
Lint-free pipe cleaners
Oil-free compressed air

FPC-CLNKIT

Fiber Connectivity Solutions

Description

This kit contains flammable alcohol and compressed air. For this reason, it can be shipped
by surface method only.

11/11

102094AE

TrueNet Structured Cabling

Fiber Connector/Adapter Cleaning kit

www.te.com/adc

+1-952-938-8080

1-800-366-3891

339

Introduction .................................................................... 344


Polarity Made Simple ...................................................... 345
Data Center Optical Distribution Frame with
Plug-and-Play Cassettes .................................................. 346
TFP Plug-and-Play Cassettes ............................................ 349
TFP MPO Pack................................................................. 352
RMG Plug-and-Play Cassettes ......................................... 353

TrueNet High Fiber Count Plug-and-Play Trunks .............. 358


TrueNet 12 Fiber Plug-and-Play Array Cables................... 361

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

343

Fiber Plug-and-Play Solutions

Plug-and-Play Microcable Trunk Assemblies .................... 356

102094AE

TrueNet Structured Cabling

Fiber Plug-and-Play Solutions

Fiber Plug-and-Play Solutions


Introduction

TrueNet Structured Cabling

102094AE

TEs TrueNet Fiber plug-and-play solutions for data center applications are designed to address
the reliability, scalability, and thermal needs of todays mission-critical data centers. The product
suite includes plug-and-play MPO solutions for TrueNet Fiber products for placement in the main
distribution area (MDA), backbone, horizontal, equipment and zone distribution areas (HDA,
EDA and ZDA). These solutions are included in the TrueNet Zero Bit-Error Warranty, and promote
increased reliability of the data center through properly managed and scalable cable density,
which encourages proper airflow and reduces overall installation and maintenance costs.

11/11

Fiber Plug-and-Play Solutions

Data centers operate at very high levels of reliability and demand design flexibility to easily
accommodate frequent adds and changes to equipment. Managing the thousands of cables that
typically comprise a data center should always be a high priority for the data center or network
managerparticularly for maximizing system performance and uptime.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

344

Fiber Plug-and-Play Solutions


Introduction

Polarity Made Simple

TrueNet plug-and-play trunks use a key up/key down fiber array as noted in TIA-568-C.3. The TrueNet
plug-and-play cassettes are wired straight through. In addition, TrueNet duplex jumpers have a duplex
clip that is easily removed for polarity changes in the field.

Rx
Tx

Key up to Key up
mated connector
B

A-to-B Patch Cord

A-to-A Patch Cord


Key up mated
connector
to transceiver
Rx
Tx

10

10

11

11

12

12

Type-A Array
Connector Cable
Cassette
Key up to Key down
mated connector
Position 1

Position 12

10

10

11

11

12

12

Position 12

Pinned
MPO Connector

Key up to Key up
mated connector

Position 1

Cassette

Non-Pinned
MPO Connector

Key up to Key down


mated connector
Position 1

Fiber Plug-and-Play Solutions

Key up mated
connector
to transceiver

102094AE

TrueNet Structured Cabling

One of the most common questions regarding MPO deployments is how the system design addresses
the polarity issue of the fiber. TEs TrueNet system employs the recommendations made in TIA
standard TIA-568-C.3.

Position 1

A
Position 12

Position 12

Example Optical Path

11/11

Figure 1: Connectivity method A for duplex signals

www.te.com/adc

+1-952-938-8080

1-800-366-3891

345

Fiber Plug-and-Play Solutions

TrueNet Structured Cabling

Its patented design incorporates the fundamentals


of cable management while using the industrys
highest fiber count MPO plug-and-play cassettes.

Features
Rapid installation of new deployments
MPO trunks can enter rack from either underfloor or overhead
Slack storage included in each rack allows for
the use of a single jumper length
On frame jumper routing provides bend
radius and physical protection with slack
easily and
intuitively managed

Applications
Provides managed high-density solution
for optical distribution frames in the main
distribution area of the data center
Can be successfully deployed in the crossconnect architecture recommended in
TIA-942, and still provide clear, managed
pathways for fiber

102094AE

TEs Data Center Optical Distribution Frame


(ODF) with plug-and-play (MPO) cassettes is the
highest density optical distribution frame solution
available today. It efficiently manages up to 1,728
fiber terminations using the 144-position block in
a single frame in either a cross-connect or interconnect design.

11/11

Fiber Plug-and-Play Solutions

Data Center Optical Distribution Frame with


Plug-and-Play Cassettes

www.te.com/adc

+1-952-938-8080

1-800-366-3891

346

Fiber Plug-and-Play Solutions

Data Center Optical Distribution Frame with


Plug-and-Play Cassettes
Specifications

Position #144

Left Side

1-48
1

1
2
3
4
5
6
7
8
9
10
11
12

13
14
15
16
17
18
19
20
21
22
23
24

25
26
27
28
29
30
31
32
33
34
35
36

CONNECTION TABLE 144 POS


MPO CONECTOR TRAY
49-96
97-144
FIBER BUNDLE NUMBER
4
5
6
7
8
9
10
11
T/B POSITION
37
49
61
73
85
97 109 121
38
50
62
74
86
98 110 122
39
51
63
75
87
99 111 123
40
52
64
76
88 100 112 124
41
53
65
77
89 101 113 125
42
54
66
78
90 102 114 126
43
55
67
79
91 103 115 127
44
56
68
80
92 104 116 128
45
57
69
81
93 105 117 129
46
58
70
82
94 106 118 130
47
59
71
83
95 107 119 131
48
60
72
84
96 108 120 132

12
133
134
135
136
137
138
139
140
141
142
143
144

FIBER
COLOR

Top View

BLUE
ORANGE
GREEN
BROWN
SLATE
WHITE
RED
BLACK
YELLOW
VIOLET
ROSE
AQUA

Fiber Bundle/MPO Connector Locations

9
10
11
12

5
6
7
8

1
2
3
4

Fiber Plug-and-Play Solutions

TrueNet Structured Cabling

Position #12

OPTICAL SPECIFICATIONS

102094AE

Plug-and-Play trunks
MPO connector
mated pairs

MPO connector
mated pairs

TFP Plug-and-Play Cassette

TFP Plug-and-Play Cassette or


Optical Distribution Frame Plug-and-Play Block
LC Adapters

850nm

1310nm

Maximum

0.7 dB

0.55 dB

Typical

0.25 dB

0.25 dB

Module Loss (measured through MPO mated pair to LC adapter)

11/11

Insertion Loss

Return Loss
Maximum

-55 dB

Trunk Loss (per meter)


Maximum

.0035 dB

.001 dB

Maximum

1.3085 dB

1.131 dB

Typical

0.6085 dB

0.531 dB

Channel/Link Loss with 31 meter trunk (100feet) (as in figure above)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

347

Fiber Plug-and-Play Solutions


Data Center Optical Distribution Frame with
Plug-and-Play Cassettes

Ordering Information
Description

Catalog Number

144-position MPO LC Blocks; Black


OM350/125 LOMMF 300 meters
LEFT block orientation

NGFB-MPML0C112

RIGHT block orientation

NGFB-MPMR0C112

OM4-50/125 LOMMF 550 meters


LEFT block orientation

NGFB-MPML0C612

RIGHT block orientation

NGFB-MPMR0C612

Singlemode
LEFT block orientation

NGFB-MPML0K512

RIGHT block orientation

NGFB-MPMR0K512

Rack
30" x 24" x 7 ft frame; black

NGFB-MDF7A144-30

Rack Accessories
ISO Pad

NGF-ACCIOSP30X24

End Guard

NGFB-ACCEGD007

End Guard ISO Pad

NGF-ACCISOPEG24

Rack Installation Kit Raised Floor

FDF-ACC146

Please refer to pages 264-266 for more information on racks and accessories.

102094AE

TrueNet Structured Cabling

-40 to 70 C (-40 to 158 F)


0 to 70 C (32 to 158 F)
0 to 70 C (32 to 158 F)

11/11

Fiber Plug-and-Play Solutions

ENvIRONMENTAL CHARACTERISTICS
Storage Temperature:
Operating Temperature:
Installation Temperature:

www.te.com/adc

+1-952-938-8080

1-800-366-3891

348

Fiber Plug-and-Play Solutions

TEs TrueNet Fiber Panels (TFP) combine the


unique features of vertical cable guides and our
patented angle-left/angle right adapters, which
offers bend radius protection, intuitive routing
and easy connector access. Our TFP series can
be ordered in one, two, four or five rack-unit
sizes to fit your unique needs. Designed for
rack or cabinet mounting in the horizontal or
equipment distribution area, the TFPs modularity,
functionality and density make them ideal for
mounting in close proximity to servers, switches,
routers and SANs.

Features
Eliminates the need for on-site fiber
terminations, which means rapid deployments

The TFPs functionality can be extended with


its plug-and-play angled cassettes, which add
up to 24-fiber terminations each for jumper
management in SANs-rich environments. These
cassettes snap into place effortlessly; and even
come from the factory prelabeled with simple
installation instructions.

Incorporates angle left/angle right adapters to


ensure proper bend radius
Use the same 1, 2, 4, and 5 rack unit standard
TFP chassis, which simplifies ordering

Specifications
TFP Series chassis utilize modular adapter packs which are unique to either the right or left position of
the chassis. The left / right position must be specified to ensure proper adapter orientation and color
order in the backplane. Information below illustrates the various configurations for the three TFP chassis.

1 Ru Chassis

5 Ru Chassis

MPL

MPR

MPL
MPL
MPL
MPL
MPL
MPL

2 Ru Chassis

MPL
MPL

MPR
MPR

MPR
MPR
MPR
MPR
MPR
MPR

11/11

4 Ru Chassis

MPL
MPL
MPL
MPL

www.te.com/adc

MPR
MPR
MPR
MPR

MPL = angle left plug-and-play cassette


MPR = angle right plug-and-play cassette

+1-952-938-8080

1-800-366-3891

349

Fiber Plug-and-Play Solutions

PANEL CONFIGuRATIONS

102094AE

TrueNet Structured Cabling

TFP Plug-and-Play Cassettes

Fiber Plug-and-Play Solutions

TrueNet Structured Cabling


102094AE

11/11

Fiber Plug-and-Play Solutions

TFP Plug-and-Play Cassettes

Angle Left Polarity / Wiring Scheme

Angle Right Polarity / Wiring Scheme

MPO Fiber Position

LC Connector

Fiber Color

MPO Fiber Position

LC Connector

MPO-1

LC-1 & LC-13

Blue

MPO-1

LC-2 & LC-14

Fiber Color
Blue

MPO-2

LC-2 & LC-14

Orange

MPO-2

LC-1 & LC-13

Orange

MPO-3

LC-3 & LC-15

Green

MPO-3

LC-4 & LC-16

Green

MPO-4

LC-4 & LC-16

Brown

MPO-4

LC-3 & LC-15

Brown

MPO-5

LC-5 & LC-17

Slate

MPO-5

LC-6 & LC-18

Slate

MPO-6

LC-6 & LC-18

White

MPO-6

LC-5 & LC-17

White

MPO-7

LC-7 & LC-19

Red

MPO-7

LC-8 & LC-20

Red

MPO-8

LC-8 & LC-20

Black

MPO-8

LC-7 & LC-19

Black

MPO-9

LC-9 & LC-21

Yellow

MPO-9

LC-10 & LC-22

Yellow

MPO-10

LC-10 & LC-22

Violet

MPO-10

LC-9 & LC-21

Violet

MPO-11

LC-11 & LC-23

Rose

MPO-11

LC-12 & LC-24

Rose

MPO-12

LC-12 & LC-24

Aqua

MPO-12

LC-11 & LC-23

Aqua

OPTICAL SPECIFICATIONS
Plug-and-Play trunks
MPO connector
mated pairs

MPO connector
mated pairs

TFP Plug-and-Play Cassette

TFP Plug-and-Play Cassette or


Optical Distribution Frame Plug-and-Play Block
LC Adapters
850nm

1310nm

Maximum

0.5 dB

0.55 dB

Typical

0.25 dB

0.25 dB

Module Loss (measured through MPO mated pair to LC adapter)


Insertion Loss

Return Loss
Maximum

-55 dB

Trunk Loss (per meter)


Maximum

.0035 dB

.001 dB

Maximum

1.1085 dB

1.131 dB

Typical

0.6085 dB

0.531 dB

Channel/Link Loss with 31 meter trunk (100feet) (as in figure above)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

350

Fiber Plug-and-Play Solutions


TFP Plug-and-Play Cassettes

11/11

(-40 to 158 F)
(32 to 158 F)
(32 to 158 F)

Ordering Information
Description

Catalog Number

Termination only rack or cabinet mount panel, black


1 RU empty panel, black; accommodates 2 plug-and-play cassettes;
T-handle latch close

TFP-1TT00-000B

2 RU empty panel, black; accommodates 4 plug-and-play cassettes;


T-handle latch close

TFP-2TT00-000B

4 RU Termination only empty chassis, accommodates 8 TFP modular adapter


packs; black

TFP-4TT00-000B

5 RU empty panel, black: accommodates 12 plug-and-play cassettes;


T-handle latch close

TFP-5TT00-000B

Plug-and-Play Cassettes
OM3 - 50/125 LOMMF 300 m
12-fiber cassettes; 6 LC (aqua) to 1 MPO adapter
Angle LEFT cassette

TFP-12MPLDQ2

Angle RIGHT cassette

TFP-12MPRDQ2

24-fiber cassettes; 12 LC (aqua) to 2 MPO adapters


Angle LEFT cassette

TFP-24MPLDQ2

Angle RIGHT cassette

TFP-24MPRDQ2

OM4- 50/125 LOMMF 550 m


12-fiber cassettes; 6 LC (aqua) to 1 MPO adapter
Angle LEFT cassette

TFP-12MPLFQ2

Angle RIGHT cassette

TFP-12MPRFQ2

24-fiber cassettes; 12 LC (aqua) to 2 MPO adapters


Angle LEFT cassette

TFP-24MPLFQ2

Angle RIGHT cassette

TFP-24MPRFQ2

Singlemode
12-fiber cassettes; 6 LCUPC to 1 MPO adapter
Angle LEFT cassette

TFP-12MPLSQ5

Angle RIGHT cassette

TFP-12MPRSQ5

24-fiber cassettes; 12 LCUPC to 2 MPO adapters


Angle LEFT cassette

TFP-24MPLSQ5

Angle RIGHT cassette

TFP-24MPRSQ5

Please refer to pages 283-285 for further specifications on TFP chassis.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

351

Fiber Plug-and-Play Solutions

102094AE

TrueNet Structured Cabling

ENvIRONMENTAL CHARACTERISTICS
Storage Temperature:
-40 to 70 C
Operating Temperature:
0 to 70 C
Installation Temperature:
0 to 70 C

Fiber Plug-and-Play Solutions

TrueNet Structured Cabling


102094AE

TE introduces an MPO adapter pack for the


TrueNet TFP series fiber panel enclosures. This
unique adapter pack contains 6 MPO adapters
to terminate 6 12 fiber trunks in each one. Due
to their high density, the MPO adapter packs are
only available for the 1 and 2 RU TFP chassis.
With the use of these adapter packs, the 1RU will
hold 144 fiber terminations, and the 2 RU will
hold 288 terminations.
The TFP MPO adapter pack is ideally suited for
applications with high density switches, where
the additional loss of the MPO cassette is not
desired. Either the TrueNet Microcable Trunks
or High Count Plug-and-play trunks can be
terminated in the back of the adapter pack
and a TrueNet Plug-and-Play Array cable can be
terminated in the front of the adapter pack.

Features
Provides higher density in 1,2 RU TFP chassis by terminating 12 fibers in each adapter
Limits insertion loss for loss sensitive optical budgets
Unique angle right /angle left design allows for optimal management of the array cables off the front of
the panel

Ordering Information
Description

Catalog Number

Termination Only Rack Mount Panel


1 RU empty panel, black; accommodates 2 modular adapter packs; T-handle
latch close

TFP-1TT00-000B

2 RU empty panel, black; accommodates 24 modular adapter packs; T-handle


latch close

TFP-2TT00-000B

MPO adapter pack


Contains 6 MPO adapters; can be installed in either left or right position

TFP-72AP0MP

Cable Clamp
For use with 1/ 2RU chassis with high fiber count trunk applications

TFP-ACC002

11/11

Fiber Plug-and-Play Solutions

TFP MPO Pack

www.te.com/adc

+1-952-938-8080

1-800-366-3891

352

Fiber Plug-and-Play Solutions

TEs RMG series fiber enclosure provides rugged


and durable protection for patching or splicing
of fiber cables. Especially designed to be userfriendly, the slide-out design and removable front
and rear panels provide convenient access points.
The RMGs modular MPO cassettes can be
used in any of the RMG series fiber enclosures
in a LC and SC connector styles in OM3 and
OM4 multimode and singlemode glass types.
Designed for easy installation and allowing rapid
deployment with less labor.

Features
Completely interchangeable between RMG panel products
Can be ordered with all standard types duplex and quad multimode and single mode adapters

Fiber Plug-and-Play Solutions

Modular design reduces installation costs

11/11

102094AE

TrueNet Structured Cabling

RMG Plug-and-Play Cassettes

www.te.com/adc

+1-952-938-8080

1-800-366-3891

353

Fiber Plug-and-Play Solutions

TrueNet Structured Cabling

Polarity / Wiring Scheme


MPO Fiber Position

LC Connector

MPO-1

LC-1 & LC-14

Fiber Color
Blue

MPO-2

LC-2 & LC-13

Orange

MPO-3

LC-3 & LC-16

Green

MPO-4

LC-4 & LC-15

Brown

MPO-5

LC-5 & LC-18

Slate

MPO-6

LC-6 & LC-17

White

MPO-7

LC-7 & LC-20

Red

MPO-8

LC-8 & LC-19

Black

MPO-9

LC-9 & LC-22

Yellow

MPO-10

LC-10 & LC-21

Violet

MPO-11

LC-11 & LC-24

Rose

MPO-12

LC-12 & LC-23

Aqua

Ordering Information
Description

Catalog Number

102094AE

Termination only rack or cabinet mount panel, black

11/11

Fiber Plug-and-Play Solutions

RMG Plug-and-Play Cassettes

1 RU empty panel, black; accommodates 3 MPO cassettes

RMG-1000-000B

2 RU empty panel, black; accommodates 6 MPO cassettes

RMG-2000-000B

4 RU empty panel, black; accommodates 12 MPO cassettes

RMG-4000-000B

Accessory
Q-Frame RMG mounting bracket

RMG-ACCQBRKT4RU

Plug-and-Play Cassettes
OM3 50/125 OMMF 300 meters cassettes
12 fiber cassettes; 3 quad LC (aqua) multimode adapters, 1 MPO adapter

RMG-12MPODQ4

24 fiber cassettes; 6 quad LC (aqua) multimode adapters, 2 MPO adapter

RMG-24MPODQ4

OM4 - 50/125 LOMMF 550 meters cassettes


12 fiber cassettes; 3 quad LC (aqua) multimode adapters, 1 MPO adapter

RMG-12MPOFQ4

24 fiber cassettes; 6 quad LC (aqua) multimode adapters, 2 MPO adapter

RMG-24MPOFQ4

Singlemode cassettes
12 fiber cassettes; 3 quad LC (blue) multimode adapters, 1 MPO adapter

RMG-12MPOSQ8

24 fiber cassettes; 6 quad LC (blue) multimode adapters, 2 MPO adapter

RMG-12MPOSQ8

www.te.com/adc

+1-952-938-8080

1-800-366-3891

354

Fiber Plug-and-Play Solutions

TrueNet plug-and-play microcable trunk


assemblies are round 12 fiber optical trunk
cables pre-terminated with a high-density MPO
connector on both ends. They can be used in
conjunction with any of the other plug-and-play
connectivity products to rapidly deploy fiber into
a data center or Local Area Network (LAN). The
TrueNet Microcable assemblies can simply be
plugged into any plug-and-play cassette in the
optical distribution frame or fiber enclosure which
eliminates the need for on-site fiber termination
and preparation.

Features
Available in OM3, OM4 and singlemode glass types
Round design eliminates preferential bend issues which results in increased density and greater
manageability
Compatible with FiberGuide Optical Raceway system to add increased protection and manageability

Fiber Plug-and-Play Solutions

Utilizes small pulling pod, which can be removed completely and quickly in the field

11/11

102094AE

TrueNet Structured Cabling

Plug-and-Play Microcable Trunk Assemblies

www.te.com/adc

+1-952-938-8080

1-800-366-3891

355

Fiber Plug-and-Play Solutions


Plug-and-Play Microcable Trunk Assemblies
Specifications
Polarity / Wiring Scheme

XXX = Length
2.75in

Barcode Label

TrueNet Structured Cabling

Connector "A"
(Key up)

Connector "B"
(key Down)

STEALTH PuLLING EYE CONFIGuRATION

102094AE

MPO B Fiber Color

MT1

MT1

Blue

MT2

MT2

Orange

MT3

MT3

Green

MT4

MT4

Brown

MT5

MT5

Slate

MT6

MT6

White

MT7

MT7

Red

MT8

MT8

Black

MT9

MT9

Yellow

MT10

MT10

Violet

MT11

MT11

Rose (Pink)

MT12

MT12

Aqua

OPTICAL SPECIFICATIONS
Plug-and-Play trunks
MPO connector
mated pairs

MPO connector
mated pairs

TFP Plug-and-Play Cassette

11/11

Fiber Plug-and-Play Solutions

7.25 .50in

MPO A

TFP Plug-and-Play Cassette or


Optical Distribution Frame Plug-and-Play Block
LC Adapters
850nm

1310nm

Maximum

0.5 dB

0.55 dB

Typical

0.25 dB

0.25 dB

Module Loss (measured through MPO mated pair to LC adapter)


Insertion Loss

Return Loss
Maximum

-55 dB

Trunk Loss (per meter)


Maximum

.0035 dB

.001 dB

Maximum

1.1085 dB

1.131 dB

Typical

0.6085 dB

0.531 dB

Channel/Link Loss with 31 meter trunk (100feet) (as in figure above)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

356

Fiber Plug-and-Play Solutions


Plug-and-Play Microcable Trunk Assemblies

ENvIRONMENTAL CHARACTERISTICS
-40 to 70 C (-40 to 158 F)
0 to 70 C (32 to 158 F)
0 to 70 C (32 to 158 F)

COMPATIBILITY WITH FIBERGuIDE


Microcable Plug-and-Play Trunk
3.0 mm
Recommended patch cord density (per in )

40

Maximum patch cord density (per in2)

44

Recommended density
FiberGuide System
3.0 mm
Trough Pile-up

2x2

2x6

4x4

4x6

4x12

4x24

2-inch

160

480

320

3-inch

480

480

960

1920

720

1440

4-inch

640

2880

960

1920

3840

MAxIMuM DENSITY

3.0 mm
Trough Pile-up

2x2

2x6

4x4

4x6

4x12

4x24

2-inch

176

528

352

528

960

2112

3-inch

528

792

1584

3168

4-inch

704

1056

2112

4224

Ordering Information
Description

Catalog Number1

OM3 - 50/125 LOMMF to 300 meters, plenum jacket

3 mm 12-fiber microcable; MPO (no pins) MPO (no pins) trunk

MRM-AF/AFJGxxxF

OM4 - 50/125 LOMMF to 550 meters; plenum jacket

11/11

3mm 12-fiber microcable; MPO (no pins) - MPO (no pins) trunk

MRM-AF/AFJPxxxF

Singlemode reduce water peak fiber, plenum jacket


3 mm 12-fiber microcable; MPO (no pins) MPO (no pins) trunk
1

MRE-AF/AFJAxxxF

xxx = length in feet.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

357

Fiber Plug-and-Play Solutions

FiberGuide System

102094AE

TrueNet Structured Cabling

Storage Temperature:
Operating Temperature:
Installation Temperature:

Fiber Plug-and-Play Solutions

Features
Construction of rugged loose-tube fiber cable
Ship with a pulling sock on one end to aid with installation
Cable assemblies contain OFNP flame rated cable
Breakouts specifically designed to work with TE TrueNet Plug-and-Play Connectivity

102094AE

TrueNet Structured Cabling

TEs TrueNet High Fiber Count Plug-and-Play


Trunks provide the backbone cabling for the
TrueNet Plug-and-Play system. These high count
trunk cables come pre-terminated with a highdensity MPO connectors on both ends and
provide an easy and efficient way to pull large
numbers of fibers at one time to help in the
rapid deployment of the TrueNet Plug-and-Play
system either in the data center or Local Area
Network (LAN). Each trunk has custom breakouts
designed to work with the TE TrueNet Plug-andPlay connectivity. The TrueNet High Fiber Count
Trunks can simply be plugged into any plug-andplay cassette in the optical distribution frame or
fiber enclosure which eliminates the need for
on-site fiber termination and preparation.

11/11

Fiber Plug-and-Play Solutions

TrueNet High Fiber Count Plug-and-Play Trunks

www.te.com/adc

+1-952-938-8080

1-800-366-3891

358

Fiber Plug-and-Play Solutions

TrueNet High Fiber Count Plug-and-Play Trunks

OPTICAL SPECIFICATIONS
FEMALE MPO CONNECTOR

MPO-A
(KEY
UP)

(6 SHOWN FOR REF ONLY QUANTITY MAY VARY)

ROUND
TUBE
SUB-UNITS

FURCATION (2)

(O.D. NOT TO EXCEED 1.00 IN FOR UP


TO 72 FIBERS AND 1.40 IN FOR 144 FIBERS.

"TFP OR NGF" LABEL

(5mm OD MAX.)

LENGTH NOT TO EXCEED 2.50 IN FOR


UP TO 72 FIBERS AND 3.50 IN FOR 144 FIBERS.)

INFORMATION
LABEL

L3

"TFP OR NGF" LABEL

MPO-B
(KEY DOWN)

L3

MT1 (REF)

L2

MT1

Blue

MT2

MT2

Orange

MT3

MT3

Green

MT4

MT4

Brown

MT5

MT5

Slate

MT6

MT6

White

MT7

MT7

Red

MT8

MT8

Black

MT9

MT9

Yellow

MT10

MT10

Violet

MT11

MT11

Rose (Pink)

MT12

MT12

Aqua

L2
MT12 (REF)

L1

2.00 in .10 in

L1

.5 in
10 in

SUB-UNIT
LABELS
"L2"

MPO B Fiber Color

MT1

+ 0 in
-1.75 in

"L3"

+ 0 in
-1.75 in

MULTI-FIBER CABLE
(INDIVIDUAL CIRCUITS NOT SHOWN REFER TO WIRE CHART)

"L1" 5
PULL SOCK

Plug-and-Play high count trunks

MPO connector
mated pairs

MPO connector
mated pairs

30 INCHES

TFP Plug-and-Play Cassette or


Optical Distribution Frame Plug-and-Play Block

TFP Plug-and-Play Cassette

LC Adapters
850nm

1310nm

Maximum

0.5 dB

0.55 dB

Typical

0.25 dB

0.25 dB

Fiber Plug-and-Play Solutions

TrueNet Structured Cabling

Polarity / Wiring Scheme


MPO A

Module Loss (measured through MPO mated pair to LC adapter)


Insertion Loss

Maximum

-55 dB

Trunk Insertion Loss (per meter)


Maximum

.0035 dB

.001 dB

Maximum

1.1085 dB

1.131 dB

Typical

0.6085 dB

0.531 dB

Channel/Link Insertion Loss with 31 meter


(100feet) trunk (as in figure above)

11/11

102094AE

Return Loss

www.te.com/adc

+1-952-938-8080

1-800-366-3891

359

Fiber Plug-and-Play Solutions

TrueNet High Fiber Count Plug-and-Play Trunks

Ordering Information
Description

Catalog Number1
MRM-AF/AFEJxxxF-yy

24 fiber, MPO-MPO (no pins) 3mm dualzip, OFNP rated

MRM-AF/AFZGxxxF

48 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFFGxxxF-yy

72 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFGGxxxF-yy

96 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFKGxxxF-yy

OM4 - 50/125 LOMMF 550 m


24 fiber, MPO-MPO (no pins) 3mm round, OFNP rated

MRM-AF/AFMPxxxF-yy

24 fiber, MPO-MPO (no pins) 3mm dualzip, OFNP rated

MRM-AF/AFZPxxxF

48 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFFPxxxF-yy

72 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFGPxxxF-yy

96 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFKPxxxF-yy

Singlemode
24 fiber, MPO-MPO (no pins) 3mm round, OFNP rated

MRM-AF/AFMAxxxF-yy

24 fiber, MPO-MPO (no pins) 3mm dualzip, OFNP rated

MRM-AF/AFZAxxxF

48 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFFAxxxF-yy

72 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFGAxxxF-yy

96 fiber, MPO-MPO (no pins) OFNP rated

MRM-AF/AFKAxxxF-yy

Note: xxx denotes length in feet of overall trunk, 001 = 1 ft, 010 = 10 ft, 100 = 100 ft
Note: yy denotes breakout definition for each end: AA = TFP to TFP, AB = TFP to ODF, BB = ODF to ODF, FF = RMG to RMG

1
2

102094AE

TrueNet Structured Cabling

24 fiber, MPO-MPO (no pins) 3mm round, OFNP rated

11/11

Fiber Plug-and-Play Solutions

OM3 - 50/125 LOMMF 300 m

www.te.com/adc

+1-952-938-8080

1-800-366-3891

360

Fiber Plug-and-Play Solutions

TEs TrueNet 12 Fiber Plug-and-Play Array Cables


provide a convenient and efficient method to
connect active equipment into the network.
These 12 fiber round 3mm cables contain a preterminated high density MPO pinned connector
on one end and either LC or SC connectors on
the other. The TrueNet 12 Fiber Plug-and-Play
Array Cables assemblies can simply be plugged
into any plug-and-play cassette in the optical
distribution frame or fiber enclosure which
eliminates the need for on-site fiber termination
and preparation.

Features
Round design with outer diameter of 3mm eliminates preferential bend issues which results in increased
density and greater manageability
Each LC or SC leg clearly labeled and identified

Fiber Plug-and-Play Solutions

Standard breakout length 18 inches, which is optimum to connect to active equipment

11/11

102094AE

TrueNet Structured Cabling

TrueNet 12 Fiber Plug-and-Play Array Cables

www.te.com/adc

+1-952-938-8080

1-800-366-3891

361

Fiber Plug-and-Play Solutions


TrueNet 12 Fiber Plug-and-Play Array Cables

B
OPTICAL SPECIFICATIONS

2MM ROUND SUB-UNITS


1

FURCATION

12 LC
SIMPLEX
CONNECTORS

1
ROUND
TUBE

TrueNet Structured Cabling

(3mm O.D. MAX)

MALE MPO CONNECTOR


(WITH ALIGNMENT PINS)

2.50 in MAX

PAIR
LABELING

KRONE
DUPLEX
CLIP (6)
18.00 in .50 in

LENGTH IN METERS

102094AE

Plug-and-Play microcable trunks


MPO connector
mated pairs
A

TITLE

INFORMATION ON THIS DOCUMENT IS


PROPRIETARY TO ADC AND SHALL
NOT BE USED, COPIED, REPRODUCED
OR DISCLOSED IN WHOLE OR IN PART
WITHOUT WRITTEN CONSENT OF ADC.
ALL DIMS AND TOLERANCES .XX:
ARE INCHES UNLESS .XXX:
OTHERWISE SPECIFIED ANGULAR:

DO NOT SCALE DRAWING

N/A
N/A
N/A
ENGR:
DWN:

12 FIBER MPO-LC TRUNK


CABLE
1421706
SHT.

MPO connector
mated pairs

DRAWING NUMBER

SIZE

M. SMRHA
M. SMRHA

REV
OF

DIMENSIONS IN INCHES
THIRD ANGLE PROJECTION

TFP Plug-and-Play
MPO adapter pack

LC / SC
connectors

850nm

1310nm

Maximum

0.50 dB

0.55 dB

Typical

0.25 dB

0.25 dB

Module Loss (measured through MPO mated pair to LC adapter)


Insertion Loss

Return Loss
Maximum

-55 dB

Trunk Insertion Loss (per meter)

11/11

Fiber Plug-and-Play Solutions

Maximum

.0035 dB

.001 dB

Maximum

1.1085 dB

1.131 dB

Typical

0.6085 dB

0.531 dB

Channel/Link Insertion Loss with 31 meter


(100 feet) trunk (as in figure above)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

362

Fiber Plug-and-Play Solutions


TrueNet 12 Fiber Plug-and-Play Array Cables

Ordering Information
Description

Catalog Number1

MPO pinned LC; 18 in breakout; 3 meter length

MRM-AM/0PJG003M-18

MPO pinned LC; 18 in breakout; 4 meter length

MRM-AM/0PJG004M-18

MPO pinned LC; 18 in breakout; 5 meter length

MRM-AM/0PJG005M-18

MPO pinned SC; 18 in breakout; 3 meter length

MRM-AM/09JG003M-18

MPO pinned SC; 18 in breakout; 4 meter length

MRM-AM/09JG004M-18

MPO pinned SC; 18 in breakout; 5 meter length

MRM-AM/09JG005M-18

OM4 - 50/125 LOMMF 550m - OFNP rated


MPO (pins) - LC; 18-inch breakout, 3 meter length

MRM-AM/0PJP003M-18

MPO (pins) - LC; 18-inch breakout, 4 meter length

MRM-AM/0PJP004M-18

MPO (pins) - LC; 18-inch breakout, 5 meter length

MRM-AM/0PJP005M-18

MPO (pins) - SC; 18-inch breakout, 3 meter length

MRM-AM/09JP003M-18

MPO (pins) - SC; 18-inch breakout, 4 meter length

MRM-AM/09JP004M-18

MPO (pins) - SC; 18-inch breakout, 5 meter length

MRM-AM/09JP005M-18

MPO pinned LC/UPC; 18 in breakout; 3 meter length

MRE-AM/0KJA003M-18

MPO pinned LC/UPC; 18 in breakout; 4 meter length

MRE-AM/0KJA004M-18

MPO pinned LC/UPC; 18 in breakout; 5 meter length

MRE-AM/0KJA005M-18

MPO pinned SC /UPC; 18 in breakout; 3 meter length

MRE-AM/07JA003M-18

MPO pinned SC/UPC; 18 in breakout; 4 meter length

MRE-AM/07JA004M-18

MPO pinned SC/UPC; 18 in breakout; 5 meter length

MRE-AM/07JA005M-18

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

363

Fiber Plug-and-Play Solutions

Singlemode Elite Cable Assemblies OFNP rated

102094AE

TrueNet Structured Cabling

OM3 - 50/125 LOMMF to 300 meters OFNP rated

Introduction ................................................................... 366


Features and Benefits..................................................... 367
Recommended and Maximum Patch Cord Densities ...... 368
FiberGuide Fiber Management System ......................... 369

Fiber Cable Raceway Systems

Plenum FiberGuide System ........................................... 380

11/11

102094AE

TrueNet Structured Cabling

Fiber Cable Raceway Systems

www.te.com/adc

+1-952-938-8080

1-800-366-3891

365

Fiber Cable Raceway Systems


Introduction

The Industry's Most Comprehensive Optical Raceway System

102094AE

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

TE's FiberGuide fiber management systems offer the greatest breadth of optical raceway products in
the industry. In response to customer requirements, TE continues to innovate and improve FiberGuide
systems, adding greater flexibility and driving down installation time to ensure a smooth deployment.
FiberGuide is a raceway system designed to protect and route fiber optic patch cords, multi-fiber cable
assemblies and intrafacility fiber cable (IFC) to and from fiber splice enclosures, fiber distribution frames
and fiber optic terminal devices. FiberGuide ensures a two-inch minimum bend radius is maintained
throughout the system. Tool-less, Snap-Fit junctions, cover options and Plenum Express Exit drops
significantly reduce the amount of time required for installation.
The FiberGuide system is a complete set of products designed and
manufactured to ensure total off-frame protection and ease of use.
Basic components include horizontal and vertical straight sections,
horizontal and vertical elbows, downspouts, junctions and numerous
support hardware and flex-tube kits.
Available in a variety of sizes:
2x2 Ideal for smaller installations or for vertical routing of a maximum
of four hundred 2 mm fiber optic patch cords. All 2x2 FiberGuide
products are shipped with covers.

2x6 Designed for height restricted environments, this robust


system provides the same support and system flexibility of the traditional
4-inch-high system while saving 2 inches of overhead space. It features
a maximum capacity of 1,200, 2 mm patch cords.

4x4 Features the maximum capacity to support 1,600, 2 mm patch


cords. It has been engineered to allow straight sections to be
self-supporting over a span of up to 1.83 m (6 feet).

4x6 Features the same benefits of the 4-inch system and a maximum
trough capacity of 2,400, 2 mm patch cords.

4x12 The 12-inch-wide trough has a maximum capacity to support


nearly 5,000, 2 mm patch cords. Perfect for runs over fiber frame
lineups and perimeter routes.

4x24 The 4x24-inch system is the ultimate raceway solution to


securely route and protect patch cords over high-density optical
distribution frames including TE's Data Center Optical Distribution Frame
(ODF). Designed for maximum capacity, this robust system provides the
same support and flexibility as the traditional 4x12-inch system while
doubling capacity.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

366

Fiber Cable Raceway Systems

Features and Benefits


Speed of Installation
FiberGuide systems feature a variety of products that allow for quick and easy installation. Express Exit
drops as well as tool-less products including Snap-Fit junctions, snap-on covers and new hinged cover
options save valuable time for installers.
Speed of Deployment
The Express Exit system enables new drops to be added or removed quickly and easily. A drop can be added
into a fully loaded raceway in secondswithout cutting.

Fiber Protection
TEs fiber expertise translates into maximum protection for your network. Two inch minimum bend radius is
maintained throughout the system regardless of the raceway size.
Strength and Durability
100% raceway reliabilitystands up to any challenge.

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

367

Fiber Cable Raceway Systems

Raceway Flexibility
FiberGuide features 38 support structures, over 75 fittings, multiple drop options and several other
components to suit any application you create.

102094AE

TrueNet Structured Cabling

Features and Benefits

Fiber Cable Raceway Systems

Recommended and Maximum Patch Cord Densities


Recommended capacity takes into consideration random jumper placement into the FiberGuide
system. Maximum density refers to the maximum number of fiber jumpers in a given cross-section of a
FiberGuide installation. The TracerLight Connector Identification System is TE's newest patch cord solution. It features slightly different dimensions than standard patch cords.

TrueNet Structured Cabling

Recommended/Maximum Density
1.7 mm
Patch Cords (per in2)

2.0 mm
Patch Cords (per in2)

3.0 mm
Patch Cords (per in2)

120/142

90/102

40/44

Trough Pileup
Recommended/Maximum Density
2-Inch

3-Inch

TracerLight Patch Cords


65 Patch Cords per in2
2-inch

3-inch

4-inch

4x24 System

3120

4680

6420

4-Inch

4x24 System
1.7 mm

5760/6816

8640/10224

11520/13632

4x12 System

1560

2340

3120

2.0 mm

4320/4869

6480/7344

8640/9792

4x6 System

780

1170

1560

3.0 mm

1920/2112

2880/3168

3840/4224

4x4 System

520

780

1040

2x6 System

780

1.7 mm

2880/3408

4320/5112

5760/6816

2x2 System

260

2.0 mm

2160/2448

3240/3672

4320/4896

3.0 mm

960/960

1440/1584

1920/2112

1.7 mm

1440/1704

2160/2556

2880/3408

2.0 mm

1080/1224

1620/1836

2160/2448

3.0 mm

480/528

720/792

960/1056

1-800-366-3891

368

4x12 System

4x6 System

102094AE

1.7 mm

960/1136

1440/1704

1920/2272

2.0 mm

720/816

1080/1224

1440/1632

3.0 mm

320/352

480/528

640/704

1.7 mm

1440/1740

2.0 mm

1080/1224

3.0 mm

480/528

1.7 mm

480/568

2.0 mm

360/408

3.0 mm

160/176

2x6 System

2x2 System

11/11

Fiber Cable Raceway Systems

4x4 System

www.te.com/adc

+1-952-938-8080

Fiber Cable Raceway Systems


FiberGuide Fiber Management System

Express Exits Units (For use with 4x4, 4x6, 4x12 and 4x24 systems)
Ordering Information
Catalog Number

TrueNet Structured Cabling

Description

Black System

Yellow System

2-inch Express Exit Unit


4-inch Express Exit base with base cover
4-inch Express Exit rear cover kit
Rear cover, 4-inch Express Exit4x4 system
Rear cover, 4-inch Express Exit4x6 system
Rear cover, 4-inch Express Exit4x12 system
Low profile Express Exit

FGS-MEXP-A/B/F
FGS-MEXP-E-A/B/F
FGS-MEXC-E-A/B/F
FGS-MEXC-E-A
FGS-MEXC-E-B
FGS-MEXC-E-F
FGS-MEXP-LP-A/B/F

FGSB-MEXP-A/B/F
FGSB-MEXP-E-A/B/F
FGSB-MEXC-E-A/B/F
FGSB-MEXC-E-A
FGSB-MEXC-E-B
FGSB-MEXC-E-F
FGSB-MEXP-LP-A/B/F

2x2 Fittings and Junctions

Express Exits

Express Exit

Ordering Information
Catalog Number
Description

Yellow System

Black System

2x2
2x2
2x2
2x2
2x2
2x2
2x2
2x2
2x2
2x2
2x2

FGS-MHXP-C
FGS-MHTA-C
FGS-MH4A-C
FGS-MH9A-C
FGS-MDSA-AC
FGS-HMEC-C1
FGS-MU4A-C
FGS-MD4A-C
FGS-MU9A-C
FGS-MD9A-C
FGS-MJWR-C

FGSB-MHXP-C
FGSB-MHTA-C
FGSB-MH4A-C
FGSB-MH9A-C
FGSB-MDSA-AC
FGS-HMEC-C1
FGSB-MU4A-C
FGSB-MD4A-C
FGSB-MU9A-C
FGSB-MD9A-C
FGSB-MJWR-C

horizontal cross with cover


horizontal tee with cover
45 horizontal elbow with cover
90 horizontal elbow with cover
to 4-inch straight adapter with cover
end cap kit (includes junction)
45 up elbow with cover
45 down elbow with cover
90 up elbow with cover
90 down elbow with cover
junction

FGS-MHTA-C

2x2 Straight Section


Ordering Information
Yellow System

Black System

2x2 horizontal straight section with


cover (6 feet)

FGS-MSHA-C

FGSB-MSHA-C
FGS-MSHA-C

2x2 Downspout Options


Ordering Information

Description

Yellow System

Black System

11/11

Catalog Number
2x2 standard downspout with cover
2x2 extended downspout with cover
2x2 flex tube attachment with 5-foot length
2-inch flex tube and 2x2 junction
2x2 extended downspout kit with 2-foot
length 2-inch flex tube and cover
Dual 7/8 -inch flex tube attachment with
(2) 5-foot lengths flex tube and 2x2
junction
Kit of ten 7/8 -inch flex tube clamps

FGS-MSDS-C
FGS-MDSP-C
FGS-MEX1-C-5F

FGSB-MSDS-C
FGSB-MDSP-C
FGSB-MEX1-C-5F

FGS-KDH2-C

FGSB-KDH2-C

FGS-KT03-C

FGSB-KT03-C

FGS-HSHS-C1

FGS-HSHS-C1

FGS-MSDS-C

Note: Catalog number is the same for both yellow and black systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

369

Fiber Cable Raceway Systems

102094AE

Catalog Number
Description

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
2x2 Direct Support Kits

102094AE

Description

Catalog Number1

2x2
2x2
2x2
2x2
2x2

FGS-HLR2-C
FGS-BTBS-C
FGS-BTBL-C
FGS-HDCB-C
FGS-HUFB-C

ladder rack support kit


bay top short L bracket kit
bay top long L bracket kit
digital cableway support kit
underfloor support kit

FGS-HLR2-C

2x2 Track Support Kits


Ordering Information
Description

Catalog Number1

2x2 aluminum track support kit (6-feet)


New threaded rod kit (5/8 -inch)
New threaded rod kit (1/2 -inch)
2x2 track connecting bar kit
Ladder rack bracket kit (5/8 -inch)
Threaded rod 12" long
Dual threaded rod bracket kit

FGS-HASK-C
FGS-HTR2-5/8
FGS-HTR2-1/2
FGS-HAEJ-C
FGS-HLDR-5/8
FGS-HTHR-5/8-12
FGS-HTUB-2-AB

FGS-HASK-C

2x6 Fittings
Ordering Information
Catalog Number
Description

Yellow System

Black System

2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6
2x6

FGS-MDSP-G
FGS-MHRT-G
FGS-MHXP-G
FGS-MH9E-G
FGS-MD9E-G
FGS-MH4E-G
FGS-MU4E-G
FGS-MD4E-G
FGS-MDSA-GA
FGS-MDSA-GB
FGS-MTRM-G
FGS-HMEC-G1
FGS-MEXP-LP-G

FGSB-MDSP-G
FGSB-MHRT-G
FGSB-MHXP-G
FGSB-MH9E-G
FGSB-MD9E-G
FGSB-MH4E-G
FGSB-MU4E-G
FGSB-MD4E-G
FGSB-MDSA-GA
FGSB-MDSA-GB
FGSB-MTRM-G
FGS-HMEC-G1
FGSB-MEXP-LP-G

to 2x2 downspout
horizontal T
horizontal cross
90 horizontal elbow
90 down elbow
45 horizontal elbow
45 up elbow with cover
45 down elbow
to 4x4 adapter
to 4x6 adapter
trumpet flare
end cap
Express Exit

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

Ordering Information

2x6 Straight Section


Ordering Information
Catalog Number
Description

Yellow System

Black System

2x6 horizontal straight section (6-feet)


2x6 horizontal straight section hinged cover

FGS-MSHS-G
FGS-MSNC-B/G

FGSB-MSHS-G
FGSB-MSNC-B/G

FGS-MSHS-G

1
Note: Catalog number is the same for both yellow and black systems, support kits
are the same for both systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

370

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
2x6 Junction
Ordering Information
Yellow System

Black System

2x6 junction

FGS-JUNC-G

FGSB-JUNC-G

FGS-JUNC-G

4x4 Fittings and Junctions


Ordering Information
Catalog Number
FGS-MDSP-A
4x4 downspout
FGS-MCDS-AB
4x4 and 4x6 downspout cover
FGS-MDSP-EX-A
4x4 extended downspout
4x4 and 4x6 extended downspout cover FGS-MCDS-EX-AB
FGS-MHRT-A
4x4 horizontal T
FGS-SHRT-A
4x4 horizontal T cover
FGS-MHXP-A
4x4 horizontal cross
FGS-SHXP-A
4x4 horizontal cross cover
FGS-MH9E-A
4x4 90 horizontal elbow
FGS-SH9E-A
4x4 90 horizontal elbow cover
FGS-MH4E-A
4x4 45 horizontal elbow
FGS-SH4E-A
4x4 45 horizontal elbow cover
FGS-MU9E-A
4x4 90 up elbow with cover
FGS-MD9E-A
4x4 90 down elbow
FGS-SD9E-A
4x4 90 down elbow cover
FGS-MU4E-A
4x4 45 up elbow with cover
FGS-MD4E-A
4x4 45 down elbow
FGS-SD4E-A
4x4 45 down elbow cover
FGS-MDSA-AB
4x4 to 4x6 straight adapter
FGS-SDSA-AB
4x4 to 4x6 straight adapter cover
FGS-HMEC-A1
4x4 end cap
4x4 snap-fit junction
FGS-MFAW-A
4x4 cut-in T
FGS-MHIS-A
Cut-in T fixture
FGS-MHIS-JIG-A/B/F1
4x4 IFC tie bracket
FGS-HIFC-A1

Black System
FGSB-MDSP-A
FGSB-MCDS-AB
FGSB-MDSP-EX-A
FGSB-MCDS-EX-AB
FGSB-MHRT-A
FGSB-SHRT-A
FGSB-MHXP-A
FGSB-SHXP-A
FGSB-MH9E-A
FGSB-SH9E-A
FGSB-MH4E-A
FGSB-SH4E-A
FGSB-MU9E-A
FGSB-MD9E-A
FGSB-SD9E-A
FGSB-MU4E-A
FGSB-MD4E-A
FGSB-SD4E-A
FGSB-MDSA-AB
FGSB-SDSA-AB
FGS-HMEC-A1
FGSB-MFAW-A
FGSB-MHIS-A
FGS-MHIS-JIG-A/B/F1
FGS-HIFC-A1

FGS-MDSP-A

FGS-MH9E-A

FGSB-MFAW-A

4x4 Straight Section


Ordering Information
Catalog Number

11/11

Description

Yellow System

Black System

4x4 horizontal straight section (6 feet)


4x4 horizontal straight section hinged
cover (6 feet)
4x4 expandable straight section

FGS-MSHS-A
FGS-MSHC-A

FGSB-MSHS-A
FGSB-MSHC-A

FGS-MVAR-A

FGSB-MVAR-A

FGS-MSHS-A

Note: Catalog number is the same for both yellow and black systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

371

Fiber Cable Raceway Systems

Yellow System

Description

102094AE

TrueNet Structured Cabling

Catalog Number
Description

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
4x4 and 4x6 Downspout Options
Ordering Information

102094AE

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

Catalog Number
Description

Yellow System

Black System

4x4 downspout junction kit


2x2 flex tube attachment with 5-foot length
2-inch flex tube and 2x2 junction
4x4/4x6 downspout insert (adapts to 2x2 system)
4x4 trumpet flare kit
4-inch square to 2-inch round adapter with
5-feet flex tubing
4-inch square to 2-inch round adapter with
10-feet flex tubing
4-inch square to 2-inch round adapter with
15-feet flex tubing
4x4 single flex tube attachment with (1) 5-foot
length 2-inch flex tubing
4x4 dual flex tube attachment with (2) 5-foot
lengths 2-inch flex tubing

FGS-MJWR-A
FGS-MEX1-C-5F

FGSB-MJWR-A
FGSB-MEX1-C-5F

FGS-HDSI-AB1
FGS-MTRM-A
FGS-ASRI-5F

FGS-HDSI-AB1
FGSB-MTRM-A
FGSB-ASRI-5F

FGS-ASRI-10F

FGSB-ASRI-10F

FGS-ASRI-15F

FGSB-ASRI-15F

FGS-KT03-A1

FGSB-KT03-A1

FGS-KT03-A

FGSB-KT03-A

FGS-MDSP-EX-A

2x6, 4x4 and 4x6 Support Kits


Ordering Information
Description

Catalog Number1

New threaded rod bracket (5/8 -inch)


New threaded rod bracket (1/2 -inch)
Modified new threaded rod bracket (5/8 -inch)
Existing threaded rod bracket (5/8 -inch)
Existing threaded rod bracket (1/2 -inch)
Modified existing threaded rod bracket (5/8 -inch)
Center support bracket (5/8 -inch)
Center support bracket (1/2 -inch)
L bay support bracket
Digital cableway bracket kit (12-inch)
Digital cableway bracket kit (15-inch)
Top support C-bracket
Top support low profile C-bracket
Ladder rack center support bracket kit
Threaded rod, 5/8 -11x12-inch
Threaded rod, 5/8 -11x30-inch
Threaded rod, 5/8 -11x72-inch
Auxiliary framing clip kit 5/8 -11 thread
Auxiliary framing clip kit 1/2 -11 thread
Adjacent angle support bracket 5/8 -11/36-inch
Adjacent angle support bracket 5/8 -11/48-inch
Adjacent angle support bracket 1/2 -13/36-inch
Adjacent angle support bracket 1/2 -13/48-inch
Ladder rack bracket kit (5/8 -inch)
Unistrut nut kit (5/8 -inch)

FGS-HNTR-5/8
FGS-HNTR-1/2
FGS-HNTR-5/8-A
FGS-HETR-5/8
FGS-HETR-1/2
FGS-HETR-5/8-A
FGS-HTUB-5/8
FGS-HTUB-1/2
FGS-HLBK
FGS-HCBL-12
FGS-HCBL-15
FGS-HNTS-5/8
FGS-HNTS-5/8-LP
FGS-HNLR-AB
FGS-HTHR-5/8-12
FGS-HTHR-5/8-30
FGS-HTHR-5/8-72
FGS-HFCK-5/8
FGS-HFCK-1/2
FGS-HASB-5/8-36
FGS-HASB-5/8-48
FGS-HASB-1/2-36
FGS-HASB-1/2-48
FGS-HLDR-5/8
FGS-HDGR

FGS-HNTR-XX

1
Note: Catalog number is the same for both yellow and black systems, support kits
are the same for both systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

372

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
4x6 Fittings and Junctions
Ordering Information
Yellow System

Black System

4x6 downspout
4x4/4x6 downspout cover
4x6 extended downspout
4x4/4x6 extended downspout cover
4x6 horizontal T
4x6 horizontal T cover
4x6 horizontal cross
4x6 horizontal cross cover
4x6 90 horizontal elbow
4x6 90 horizontal elbow cover
4x6 45 horizontal elbow
4x6 45 horizontal elbow cover
4x6 45 up elbow with cover
4x6 45 down elbow
4x6 45 down elbow cover
4x6 90 down elbow
4x6 90 down elbow cover
4x6 90 up elbow with cover
4x6 cut-in T
Cut-in T fixture
4x6 trumpet flare kit
4x6 end cap
4x6 snap-fit junction
4x6 IFC tie bracket

FGS-MDSP-B
FGS-MCDS-AB
FGS-MDSP-EX-B
FGS-MCDS-EX-AB2
FGS-MHRT-B
FGS-SHRT-B
FGS-MHXP-B
FGS-SHXP-B
FGS-MH9E-B
FGS-SH9E-B
FGS-MH4E-B
FGS-SH4E-B
FGS-MU4E-B
FGS-MD4E-B
FGS-SD4E-B
FGS-MD9E-B
FGS-SD9E-B
FGS-MU9E-B
FGS-MHIS-B
FGS-MHIS-JIG-A/B/F1
FGS-MTRM-B
FGS-HMEC-B1
FGS-MFAW-B
FGS-HIFC-B1

FGSB-MDSP-B
FGSB-MCDS-AB
FGSB-MDSP-EX-B
FGSB-MCDS-EX-AB2
FGSB-MHRT-B
FGSB-SHRT-B
FGSB-MHXP-B
FGSB-SHXP-B
FGSB-MH9E-B
FGSB-SH9E-B
FGSB-MH4E-B
FGSB-SH4E-B
FGSB-MU4E-B
FGSB-MD4E-B
FGSB-SD4E-B
FGSB-MD9E-B
FGSB-SD9E-B
FGSB-MU9E-B
FGSB-MHIS-B
FGS-MHIS-JIG-A/B/F1
FGSB-MTRM-B
FGS-HMEC-B1
FGSB-MFAW-B
FGS-HIFC-B1

FGS-MDSP-B

FGSB-MH9E-B

FGSB-MFAW-B

FGS-MU9E-B

Ordering Information
Catalog Number
Yellow System

Black System

6-foot horizontal straight section


6-foot horizontal straight section hinged cover
4x6 expandable straight section

FGS-MSHS-B
FGS-MSHC-B
FGS-MVAR-B

FGSB-MSHS-B
FGSB-MSHC-B
FGSB-MVAR-B

FGSB-MTRM-B

11/11

Description

FGS-MSHS-B

1
2

Note: Catalog number is the same for both yellow and black systems.
Dual downspout requires 2 covers

www.te.com/adc

+1-952-938-8080

1-800-366-3891

373

Fiber Cable Raceway Systems

4x6 Straight Section

102094AE

TrueNet Structured Cabling

Catalog Number
Description

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
4x12 Fittings
Ordering Information
Description

Yellow System

Black System

4x12 horizontal T
4x12 to 4x6 horizontal T
4x12 horizontal cross
4x12 to 4x6 horizontal cross
4x12 to 4x6 adapter
4x12 90 horizontal elbow
4x12 45 horizontal elbow
4x12 end cap
4x12 cut-in T
Cut-in T fixture
4x12 45 up elbow with cover
4x12 45 down elbow
4x12 90 down elbow
4x12 trumpet flare kit
4x12 downspout with 4x6 exit
4x12 downspout with rear T
4x12 to dual 4x6 adapter
4x12 IFC tie bracket

FGS-MHRT-F
FGS-MHRT-F/B
FGS-MHXP-F
FGS-MHXP-B/F
FGS-MDSA-FB
FGS-MH9E-F
FGS-MH4E-F
FGS-HMEC-F1
FGS-MHIS-F
FGS-MHIS-JIG-A/B/F1
FGS-MU4E-F
FGS-MD4E-F
FGS-MD9E-F
FGS-MTRM-F
FGS-MDSP-F
FGS-MDRT-F
FGS-MDSA-F2B
FGS-HIFC-F1

FGSB-MHRT-F
FGSB-MHRT-F/B
FGSB-MHXP-F
FGSB-MHXP-B/F
FGSB-MDSA-FB
FGSB-MH9E-F
FGSB-MH4E-F
FGS-HMEC-F1
FGSB-MHIS-F
FGS-MHIS-JIG-A/B/F1
FGSB-MU4E-F
FGSB-MD4E-F
FGSB-MD9E-F
FGSB-MTRM-F
FGSB-MDSP-F
FGSB-MDRT-F
FGSB-MDSA-F2B
FGS-HIFC-F1

FGS-MH9E-F

FGSB-MDSA-FB

FGSB-MTRM-F
Covers are available
for 4x12 fittings.
Please contact TE
or visit www.TE.com

4x12 Straight Section


Ordering Information
Catalog Number
Description

Yellow System

Black System

6-foot horizontal straight section


4x12 expandable straight section
6-foot hinged cover

FGS-MSHS-F
FGS-MVAR-F
FGS-MSNC-F

FGSB-MSHS-F
FGSB-MVAR-F
FGSB-MSNC-F

FGS-MSHS-F

102094AE

4x12 Junction

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

Catalog Number

Ordering Information
Catalog Number
Description

Yellow System

Black System

4x12 snap-fit junction

FGS-MFAW-F

FGSB-MFAW-F

FGS-MFAW-F

4x12 System Support Kits


Ordering Information
Description

Catalog Number1

New threaded rod bracket (5/8 -inch)


Existing threaded rod bracket (5/8 -inch)
Top support threaded rod bracket kit
Top support low profile threaded rod bracket kit
Trapeze bracket kit
Ladder rack center support bracket kit

FGS-HNTR-F-5/8
FGS-HETR-F-5/8
FGS-HNTS-F-5/8
FGS-HNTS-F-5/8-LP
FGS-HNTP-F-5/8
FGS-HNLR-F

1
Note: Catalog number is the same for both yellow and black systems, support kits
are the same for both systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

374

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
Vertical Duct Systems
Ordering Information
Yellow System

Black System

2x2 vertical slotted duct kit, 6-feet


2x2 vertical 1.5-inch slotted duct kit, 6-feet
2x2 vertical solid duct
1x2 vertical duct kit
1x2 solid vertical duct kit
2x2 vertical to 1x2 vertical adapter bracket
2x2 vertical slotted duct, 6-feet
2x2 vertical 1.5-inch slotted duct, 6-feet
Cover for 2x2 vertical duct, 6-feet
2x2 vertical duct mounting bracket
4x4 vertical duct kit
4x4 vertical adapter junction kit
4x4 vertical slotted duct, 6-feet
Cover for 4x4 vertical duct, 6-feet
4x4 vertical duct mounting bracket

FGS-KTW1-C
FGS-KTW1-CA
FGS-KTW4-C
FGS-KTW1-E
FGS-KTW4-E
FGS-ACC063
FGS-MSHS-C
FGS-MSHS-CA
FGS-MSHC-C
FGS-HWMB-C1
FGS-KTW2-D
FGS-MJWR-D
FGS-MSHS-D
FGS-MSHC-D
FGS-HWMB-D1

FGSB-KTW1-C
FGSB-KTW1-CA
FGSB-KTW4-C
FGSB-KTW1-E
FGSB-KTW4-E
FGSB-ACC063
FGSB-MSHS-C
FGSB-MSHS-CA
FGSB-MSHC-C
FGS-HWMB-C1
FGSB-KTW2-D
FGSB-MJWR-D
FGSB-MSHS-D
FGSB-MSHC-D
FGS-HWMB-D1

FGS-KTW2-D

Accessories
Ordering Information
Catalog Number
Flex Tubing
2-inch outer diameter slotted flex tube, 5-feet
2-inch outer diameter slotted flex tube, 10-feet
2-inch outer diameter slotted flex tube, 15-feet
1-inch outer diameter slotted flex tube, 100-feet
1-inch outer diameter slotted flex tube, 150-feet
1-inch outer diameter slotted flex tube, 200-feet
1-inch outer diameter slotted flex tube, 250-feet
7
/8 -inch outer diameter slotted flex tube, 5-feet
7
/8 -inch outer diameter slotted flex tube, 10-feet
7
/8 -inch outer diameter slotted flex tube, 15-feet
7
/8 -inch outer diameter slotted flex tube, 200-feet
Accessories
Hinge kit for 4x4 and 4x6 covers (kit of 1)
Self-closing hinge (kit of 3)
Retainer rings (kit of 10)
Trough cover clip kit
Mitre box and saw
Quick knobs (10)
Quick knobs (100)
Flex tube clamps (kit of 10)

11/11

Yellow System

Black System

FGS-MIDY-5F
FGS-MIDY-10F
FGS-MIDY-15F
FGS-MLDY-100F
FGS-MLDY-150F
FGS-MLDY-200F
FGS-MLDY-250F
FGS-MFTY-5F
FGS-MFTY-10F
FGS-MFTY-15F
FGS-MFTY-200F

FGSB-MIDY-5F
FGSB-MIDY-10F
FGSB-MIDY-15F
FGSB-MLDY-100F
FGSB-MLDY-150F
FGSB-MLDY-200F
FGSB-MLDY-250F
FGSB-MFTY-5F
FGSB-MFTY-10F
FGSB-MFTY-15F
FGSB-MFTY-200F

FGS-HHGK1
FGS-HVHG1
FGS-HFRR-101
FGS-KT091
FGS-MKIT-ABF1
FGS-KQKB1
FGS-HQKK1
FGS-HHEC-101

FGS-MIDY

Fiber Cable Raceway Systems

Description

102094AE

TrueNet Structured Cabling

Catalog Number
Description

FGS-HHGK1
FGS-HVHG1
FGS-HFRR-101
FGS-KT091
FGS-MKIT-ABF1
FGS-KQKB1
FGS-HQKK1
FGS-HHEC-101

Note: Catalog number is the same for both yellow and black systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

375

Fiber Cable Raceway Systems


FiberGuide Fiber Management System

4x24 System
Straight Section and Snap-Fit Junction 4" H x 24" W

Straight Section
(FGS-MSHS-H)

Ordering Information
Catalog Number
Description

Yellow System

Black System

4x24 straight section; horizontal straight section, 6' long

FGS-MSHS-H

FGSB-MSHS-H

Snap-fit Junction
The Snap-Fit Junction assembly is available for the 24-inch
FiberGuide System. The Snap-Fit junction is a completely toolless junction. No additional tools are required for installation
or removal. The junction exhibits superior holding force and
accommodates support brackets. A warning label is included
with each junction kit.
Snap-Fit junction
(FGS-MFAW-H)

Ordering Information
Catalog Number
Description

Yellow System

Black System

4x24 Snap-Fit junction

FGS-MFAW-H

FGSB-MFAW-H

102094AE

The unique double wall channel design of the 4x24 straight


section provides exceptional strength and durability for high
fiber count applications and allows the standard system to be
attached to the support structure without the need to cut or
drill any holes within the trough. The six channel design ensures
that the patch cords will not come in contact with any screw
heads or bolts, an important consideration in 4x24 systems
where higher cable counts apply increased pressure on patch
cords at the bottom of the trough.

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

Straight Section

www.te.com/adc

+1-952-938-8080

1-800-366-3891

376

Fiber Cable Raceway Systems


FiberGuide Fiber Management System
4x24 System
Fittings 4" H x 24" W

TrueNet Structured Cabling

4x24 Inch Section

End Cap
(FGS-HMEC-H)

Horizontal Cross with


Dual 12" Exits
(FGS-MHXP-F/H)

45 Horizontal Elbow
(FGS-MH4E-H)

Horizontal T
with Single 12" Exit
(FGS-MHRT-H/F)

Horizontal Cross
(FGS-MHXP-H)

12" Cut-in T
(FGS-MHIS-F/H)

Ordering Information
Yellow System

Black System

45 horizontal ebow

FGS-MH4E-H

FGSB-MH4E-H

Horizontal T with single 12" exit

FGS-MHRT-H/F

FGS-MHRT-H/F1

Horizontal T with three 24" exits

FGS-MHRT-H1

FGS-MHRT-H1

Horizontal cross

FGS-MHXP-H

FGSB-MHXP-H

Horizontal cross with dual 12" exits

FGS-MHXP-F/H

FGSB-MHXP-F/H

45 up elbow

FGS-MU4E-H

FGSB-MU4E-H

45 down elbow

FGS-MD4E-H

FGSB-MD4E-H

12" cut-in T for 4x242

FGS-MHIS-F/H

FGSB-MHIS-F/H

6" cut-in T for 4x242

FGS-MHIS-B/H

FGSB-MHIS-B/H

11/11

Catalog Number
Description

4" cut-in T for 4x24

FGS-MHIS-A/H

FGSB-MHIS-A/H

4x24 conversions

4x24 to 4x12 adapter


4x24 end cap

1
2

FGS-MDSA-HF

FGSB-MDSA-HF

FGS-HMEC-H1

FGS-HMEC-H1

Note: Catalog number is the same for both yellow and black systems.
Designed exclusively for the 4x24" system.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

377

Fiber Cable Raceway Systems

102094AE

4x24 fittings

Fiber Cable Raceway Systems


FiberGuide Fiber Management System

4x24 downspouts and attachments feed fiber from overhead straight sections into
fiber optic equipment below.

Island T with Single 12" Exit


(FGS-ISLAND-H/F)

Trumpet Flare
(FGS-MTRM-H)

Ordering Information
Catalog Number
Yellow System

Black System

Island T with single 12" exit

FGS-ISLAND-H/F

FGSB-ISLAND-H/F

Trumpet flare

FGS-MTRM-H1

FGS-MTRM-H1

102094AE

Description

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

4x24 System
Downspouts 4" H x 24" W

Note: Catalog number is the same for both yellow and black systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

378

Fiber Cable Raceway Systems


FiberGuide Fiber Management System

Variable Fitting Support Locator


Kit Horizontal Elbow
(FGS-MH4E-H-VS)

Variable Fitting Support Locater Kit


Horizontal T with Single 12" Exit
(FGS-MHRT-H/F-VS)

Variable Support Bracket - Horiz. Elbow


(FGS-MH4E-H-VS)

Variable Support Bracket - Horiz. T


(FGS-MHRT-H/F-VS)

Variable Fitting Support


Locater Kit Horizontal Cross
(FGS-MHXP-H-VS)

Variable Fitting Support Locater Kit


Horizontal Cross with Dual 12" Exits
(FGS-MHXP-F/H-VS)
Variable Support Bracket - Horiz. Cross
(FGS-MHXP-F/H-VS)

Threaded Rod Ref


12.7 mm
(.5")

Variable Support Bracket - Horiz. Cross


(FGS-MHXP-H-VS)
Quick Knob

Split Nut
Bracket
Clip

Existing Threaded Rod Trapeze Bracket


50.8 mm
(2")

50.8 mm
(2")

Existing 5/8 Threaded Rod Trapeze Bracket Kit


(FGS- HETP-H-5/8)

793.8 mm
(31.25")

736.6 mm
(29")

New 5/8 Threaded Rod Trapeze Bracket Kit


(FGS-HNTP-H-5/8)
New 5/8 Threaded Rod Trapeze Bracket Kit
(FGS-HNTP-H-5/8)

Ordering Information
Existing 5/8 Threaded Rod Trapeze Bracket Kit
(FGS- HETP-H-5/8)

Catalog Number1

4x24 System Support Kits

Horizontal elbow

FGS-MH4E-H-VS

11/11

Variable fitting support locater kit for;


Horizontal T with single 12" exit

FGS-MHRT-H/F-VS

Horizontal cross

FGS-MHXP-H-VS

Horizontal cross with dual 12" exits

FGS-MHXP-F/H-VS

Threaded rod trapeze bracket kit for;

Existing; 5/8"

FGS-HETP-H-5/8

New; 5/8"

FGS-HNTP-H-5/8

Note: Support kit catalog numbers are the same for both yellow and black systems.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

379

Fiber Cable Raceway Systems

736.6 mm
(29")

844.6 mm
(33.25")

102094AE

TrueNet Structured Cabling

4x24 System Support Kits

Fiber Cable Raceway Systems

Made from sturdy aluminum, TEs Plenum


FiberGuide System protects optical fibers
by physically separating them from copper
communications cable, power cable, ground
cables, heating/ventilating ducts, water pipes and
many other obstructions commonly encountered
in plenum air spaces.

Dropped
Ceiling

Fiber
Distribution
Devices

Fiber
Optic
Equipment

New Plenum FiberGuide Express Exits allow


jumpers to be permanently or temporarily routed
to the fiber optic terminal (FOT) equipment or
fiber frames. No cutting is required because
knockout sections can be punched out as
necessary.

Raised
Floor

Figure 1

As seen in Figure 1, the Plenum FiberGuide


System can be used above a dropped ceiling as
well as below a raised computer floor.
Figure 2 details a layout below a computer
floor. This illustration shows a plenum FiberGuide
System featuring new Express Exits.
Contact TE's Technical Assistance Center (TAC) for more information.

All plenum components, including


mounting hardware for mounting the
FiberGuide to the raised floor struts,
are available in the Plenum FiberGuide
product line.

102094AE

TEs Plenum FiberGuide System is a fiber cable


raceway system that protects optical fibers,
routed beneath raised computer room floors
and above suspended ceilings. These physical
areas, used to transport environment air, are
typically categorized as plenum air spaces by
National Electric Code (NEC) Standards. In
general, materials used in these spaces must be
non-flammable and must not emit appreciable
amounts of smoke or toxic gases when exposed
to heat or flame.

11/11

Fiber Cable Raceway Systems

TrueNet Structured Cabling

Plenum FiberGuide System

Figure 2

www.te.com/adc

+1-952-938-8080

1-800-366-3891

380

Introduction ................................................................... 382

Compact Building Cables ............................................ 393

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

381

Fiber Optic Cable Solutions

Indoor/Outdoor Cable ................................................... 383

102094AE

TrueNet Structured Cabling

Fiber Optic Cable Solutions

Fiber Optic Cable Solutions

All multimode fibers exceed IEEE 802.3z


standards for Gigabit Ethernet performance.
Fiber cable solutions also support IEEE 802.3ae
standards for 300 meter 10Gbps applications as
well as 550 meter 10Gbps applications. Advanced
construction techniques simplify termination and
allow faster installation. Each fiber cable offers
low attenuation for optimum signal reliability
while offering excellent crush, cut and abrasion
resistance. The following are the TrueNet fiber
cable solutions; additional fiber cable options are
available in TEs Fiber Cable catalog.
Features
Each fiber tested to specifications after cabling
Each fiber type available in all standard TE cable designs
All multimode fiber types exceed Gigabit Ethernet industry standards (IEEE 802.3z)
Ultra 50m fiber is laser-optimized for 300 meter 10Gbps applications (IEEE 802.3ae)
Ultra 50m fiber for 550 meter 10Gbps applications is also available

102094AE

TrueNet Structured Cabling

TEs TrueNet Fiber Optic Solutions offers a


complete family of high performance singlemode
and multimode cables, including Indoor/Outdoor
cables, Compact Building cables, Armored
versions, and patch cord/pigtail cables. All cable
is produced by highly automated manufacturing
processes and each fiber is tested to specifications
after cabling to ensure consistent quality and
dependability.

11/11

Fiber Optic Cable Solutions

Introduction

www.te.com/adc

+1-952-938-8080

1-800-366-3891

382

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Dry Loose Tube Cables:


Riser and Plenum Listed OFNR/FT-4 and OFNP/FT-6 c(ETL)us
250 m UV Colored Optical Fiber
3.0 mm (.12") Thermoplastic Tube Drygel Water Blocked
Strength Member
Flame Retardant Outer Jacket
Indoor/Outdoor Dry Loose Tube (up to 144 fibers)
250 m UV Colored Optical Fiber

Fiber Optic Cable Solutions

3.0 mm (.12") Thermoplastic Tube Drygel Water Blocked


Central Strength Member
Strength Member
Flame Retardant Outer Jacket
Rip Cord
Features
Dry cable core and dry buffer tubes provide effective water blocking without the need for
traditional gel filler
Can be placed anywhere in the network, bypassing transition points from outdoor to indoor
Installation times reduced because there is no need to clean gels
Excellent flame retardancy
Flexible design for easy installation
Color-coded buffer tubes and fibers
Wide operating temperature: -40 to +75 C (-40 to +167 F)

Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

Optical Performance

62.5/125

3.5/1.5

3.0/1.0

2001/5001

11/11

102094AE

TrueNet Structured Cabling

Indoor/Outdoor Dry Loose Tube (up to 12 fibers)

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Multimode

Singlemode

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

1
2

Ordering information follows on the next page.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

383

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Dry Loose Tube Cables:


Riser and Plenum Listed OFNR/FT-4 and OFNP/FT-6 c(ETL)us

TrueNet Structured Cabling


102094AE

11/11

Fiber Optic Cable Solutions

Guaranteed Ethernet Transmission Performance


Fast Ethernet
100 Mbps

Gigabit Ethernet
1 Gbps

10 Gigabit Ethernet
10 Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/500 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m1

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

Ordering Information
UL Type

Fibers

Dry loose tube:


in/outdoor riser

Dry loose tube:


in/outdoor plenum

Diameter

Weight

mm

in

kg/km

lb/1000'

6.5

.255

43

29

12

6.5

.255

43

29

24

10.1

.396

82

55

48

10.1

.396

82

55

72

11.9

.467

111

75

144

17.8

.700

252

169

6.6

.26

48

32

12

6.6

.26

48

32

24

6.2 x 12.6

.245 x .495

80

54

48

9.4

.37

82

55

72

11.7

.46

101

68

144

17.5

.69

315

212

Catalog Number*
QXXXDLTIORYYY

QXXXDLTIOPYYY

*Replace XXX with fiber count. Replace YYY with fiber type:
50U = 50/125 m Ultra multimode laser
010 = Singlemode
optimized to 300 m
062 = 62.5/125 m Multimode
5U5 = 50/125 m Ultra multimode laser
50E = 50/125 m multimode
optimized to 550 m

www.te.com/adc

+1-952-938-8080

1-800-366-3891

384

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

TEs line of indoor/outdoor armored loose tube


cables are designed to meet all the rigors of
the outside plant environment, and have the
necessary fire ratings to be installed inside the
building. These cables eliminate the messy gel
filler of traditional loose tube style cables with
super absorbent polymers. The installer can place
the cable anywhere in the network, bypassing
the traditional transition points required in most
installations. Cables are available with fiber
counts from 6 to 144.

Features

Compliances

No cleaning of gels, greatly reduces installati


on time

Telcordia GR-20-CORE

Reduces labor costs by eliminating transition


points at the demarcation

EIA/TIA FOTPs

Can be used outdoors or indoors in


plenum areas

ISO/IEC 11801

Fiber Optic Cable Solutions

TrueNet Structured Cabling

Armored Dry Loose Tube Cables: Plenum

Telcordia GR-409-CORE
ETL, (UL) 910, NEC OFCP, FT-6
TIA/EIA 568-B.3

Applications
Between buildings in a campus environment
Plenum rated environments
Outside plant environments

11/11

102094AE

Raised computer floors

www.te.com/adc

+1-952-938-8080

1-800-366-3891

385

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Armored Dry Loose Tube Cables: Plenum

TrueNet Structured Cabling

72 FIBEr CABLE
250 m UV Colored
Optical Fiber

250 m UV Colored
Optical Fiber

3.0 mm Thermoplastic
Tube Drygel Water
Blocked

3.0 mm Thermoplastic
Tube Drygel Water
Blocked

Strength Member

Strength Member

Flame Retardant Inner


and Outer Jacket

Flame Retardant Inner


and Outer Jacket

Interlocking Aluminum
Armor

Interlocking Aluminum
Armor

ENvIrONMENTAL CHArACTErISTICS
Storage Temperature:
-40 to 85 C (-40 to 180 F)
Operating Temperature:
-40 to 75 C (-40 to 167 F)
Installation Temperature:
0 to 60 C (-32 to 140 F)
MECHANICAL CHArACTErISTICS
Maxiumum Bend radius (in)

Maximum Tensile Load (lbf)

Fiber Count

Diameter (in)

Weight
lb/1000 ft

Short Term
(Install)

Long Term

Short Term
(Install)

Long Term

0.614

138

9.2

6.1

300

90

12

0.614

140

9.2

6.1

300

90

24

0.765

257

11.5

7.7

600

180

36

0.765

257

11.5

7.7

600

180

48

0.765

257

11.5

7.7

600

180

72

0.765

257

11.5

7.7

600

180

96

0.821

275

12.3

8.21

600

200

144

0.972

350

14.6

9.7

600

200

102094AE

12 FIBEr CABLE

11/11

Fiber Optic Cable Solutions

Specifications

www.te.com/adc

+1-952-938-8080

1-800-366-3891

386

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Armored Dry Loose Tube Cables: Plenum

Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

2001/5001

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Fast Ethernet
100Mbps

Gigabit Ethernet
1Gbps

10 Gigabit Ethernet
10Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/2000 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m1

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Multimode

Singlemode

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

Guaranteed Ethernet Transmission Performance

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

387

Fiber Optic Cable Solutions

102094AE

TrueNet Structured Cabling

Optical Performance

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Armored Dry Loose Tube Cables: Plenum


Ordering Information
6

Q006DLTIAPXXX

Q008DLTIAPXXX

12

Q012DLTIAPXXX

24

Q024DLTIAPXXX

36

Q036DLTIAPXXX

48

Q048DLTIAPXXX

72

Q072DLTIAPXXX

96

Q096DLTIAPXXX

144

Q144DLTIAPXXX

*Replace XXX with fiber type:


010 = Singlemode
062 = 62.5/125 m multimode
50E = 50/125 m multimode/orange jacket
50U = 50/125 m ultra multimode laser optimized to 300 meters
5U5 = 50/125 m ultra multimode laser optimized to 550 meters

102094AE

TrueNet Structured Cabling

Catalog Number*

11/11

Fiber Optic Cable Solutions

Fiber Count

www.te.com/adc

+1-952-938-8080

1-800-366-3891

388

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Features

Compliances

No cleaning of gels, greatly reduces


installation time

Telcordia GR-20-CORE

Reduces labor costs by eliminating transition


points at the demarcation

EIA/TIA FOTPs

Can be used outdoors or indoors in


riser areas

ISO/IEC 11801

Fiber Optic Cable Solutions

TEs innovative line of indoor/outdoor armored


loose tube cables are designed to meet all the
rigors of the outside plant environment and have
the necessary fire ratings to be installed inside
the building. These cables eliminate the messy
gel filler of traditional loose tube style cables with
super absorbent polymers. The installer can place
the cable anywhere in the network, bypassing
the traditional transition points required in most
installations. Cables are available with fiber
counts from 2 to 144 fibers.

Telcordia GR-409-CORE
ETL, (UL) 1666, NEC OFCR, FT-4
EIA/TIA 568B

Applications
Between buildings in a campus environment
Riser rated environments
Outside plant environments

11/11

102094AE

TrueNet Structured Cabling

Armored Dry Loose Tube Cables: Riser

www.te.com/adc

+1-952-938-8080

1-800-366-3891

389

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Armored Dry Loose Tube Cables: Riser

TrueNet Structured Cabling


102094AE

12 FIBEr CABLE

72 FIBEr CABLE
250 m UV Colored
Optical Fiber

250 m UV Colored
Optical Fiber

3.0 mm Thermoplastic
Tube Drygel Water
Blocked

3.0 mm Thermoplastic
Tube Drygel Water
Blocked

Strength Member

Strength Member

Interlocking Aluminum
Armor

Central Strength
Member

Flame Retardant Inner


and Outer Jackets

Interlocking Aluminum
Armor
Flame Retardant Inner
and Outer Jackets

ENvIrONMENTAL CHArACTErISTICS
Storage Temperature:
-40 to 85 C (-40 to 185 F)
Operating Temperature:
-40 to 75 C (-40 to 167 F)
Installation Temperature:
-20 to 60 C (-4 to 140 F)

MECHANICAL CHArACTErISTICS
Maxiumum Bend radius (in)

Maximum Tensile Load (lbf)

Fiber Count

Diameter (in)

Weight
lb/1000 ft

Short Term
(Install)

Long Term

Short Term
(Install)

Long Term

0.614

138

9.2

6.1

300

90

12

0.614

140

9.2

6.1

300

90

24

0.765

257

11.5

7.7

600

180

36

0.765

257

11.5

7.7

600

180

48

0.765

257

11.5

7.7

600

180

72

0.765

257

11.5

7.7

600

180

96

0.821

275

12.3

8.21

600

200

144

0.972

350

14.6

9.7

600

200

11/11

Fiber Optic Cable Solutions

Specifications

www.te.com/adc

+1-952-938-8080

1-800-366-3891

390

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Armored Dry Loose Tube Cables: Riser

Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

2001/5001

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Fast Ethernet
100Mbps

Gigabit Ethernet
1Gbps

10 Gigabit Ethernet
10Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/2000 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m1

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Multimode

Singlemode

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

Guaranteed Ethernet Transmission Performance

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

391

Fiber Optic Cable Solutions

102094AE

TrueNet Structured Cabling

Optical Performance

Fiber Optic Cable Solutions


Indoor/Outdoor Cable

Armored Dry Loose Tube Cables: Riser


Ordering Information
Weight

Catalog Number*

in

kg/km

lb/1000'

14.5

0.57

214

144

Q006DLTIARXXX

14.5

0.57

214

144

Q008DLTIARXXX

12

14.5

0.57

214

144

Q012DLTIARXXX

24

20.8

0.82

856

261

Q024DLTIARXXX

36

20.8

0.82

856

261

Q036DLTIARXXX

48

20.8

0.82

856

261

Q048DLTIARXXX

72

20.8

0.82

856

261

Q072DLTIARXXX

96

22.1

0.87

919

280

Q096DLTIARXXX

144

25.9

1.02

1502

458

Q144DLTIARXXX

*Replace XXX with fiber type:


010 = Singlemode
062 = 62.5/125 m Multimode
50E = 50/125 m Multimode
50U = 50/125 m Ultra Multimode laser optimized to 300 m
5U5 = 50/125 m Ultra Multimode laser optimized to 550 m

102094AE

TrueNet Structured Cabling

Diameter
mm

11/11

Fiber Optic Cable Solutions

Fibers

www.te.com/adc

+1-952-938-8080

1-800-366-3891

392

Fiber Optic Cable Solutions


Compact Building Cable

OFNP/FT-6 c(UL)us Plenum Cable

900m tight buffered fibers designed for


one-pass mechanical stripping
Constructions above 24 fibers
feature 12 fiber subunits
All-dielectric construction includes
aramid yarn tensile strength members
Easy-to-strip outer jacket

Applications

Compliances

Between main cross-connects and


telecommunications room

Telcordia GR-409-CORE, EIA/TIA FOTPs

Horizontal cable runs from cross-connect


to telecommunications room

(UL) 910, NEC OFNP, FT-6

TIA/EIA 568-B

Areas requiring (UL) listed flame


retardant cables
Horizontal cable runs from telecommunications
rooms to consolidation points

Optical Performance
Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

2001/5001

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Multimode

Singlemode

11/11

Fiber Optic Cable Solutions

Features TrueNet technology to improve


cable performance (up to 24 fibers)

102094AE

TrueNet Structured Cabling

Features

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

1
2

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

393

Fiber Optic Cable Solutions


Compact Building Cable

OFNP/FT-6 c(UL)us Plenum Cable

TrueNet Structured Cabling


102094AE

11/11

Fiber Optic Cable Solutions

12-Fiber Cable

72-Fiber Cable

12-Fiber Subunit

PVC Outer Jacket

PVDF Outer Jacket

900 m Tight
Buffered Fiber

Aramid Yarn
Strength Member

Aramid Yarn
Strength Member

Rip Cord
900 m Tight
Buffered Fiber

Dielectric Central
Strength Member

Dielectric Central
Strength Member

Ripcord
Guaranteed Ethernet Transmission Performance
Fast Ethernet
100 Mbps

Gigabit Ethernet
1 Gbps

10 Gigabit Ethernet
10 Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/2000 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

Ordering Information
Fibers

Diameter

Weight

Minimum Bend radius


Loaded
Installed

Catalog Number*

mm

in

kg/km

lb/1000'

mm

in

mm

in

4.1

0.16

34

23

81.3

3.2

40.6

1.6

6004LFPCBCYYY

4.8

0.19

43

29

96.5

3.8

48.3

1.9

6006LFPCBCYYY

5.3

0.21

59

40

106.7

4.2

53.3

2.1

6008LFPCBCYYY

12

6.4

0.25

73

49

127

5.0

63.5

2.5

6012LFPCBCYYY

18

6.4

0.25

73

49

127

5.0

63.5

2.5

6018LFPCBCYYY

24

7.4

0.29

125

84

147.3

5.8

73.7

2.9

6024LFPCBCYYY

36

13.5

0.53

171

115

269.2

10.6

134.6

5.3

6036LFPCBCYYY

48

16.3

0.69

261

176

325.1

12.8

162.6

6.4

6048LFPCBCYYY

72

19.1

0.75

322

216

381

15

190.5

7.5

6072LFPCBCYYY

96

22.9

0.90

325

218

457.2

18

228.6

9.0

6096LFPCBCYYY

144

23.4

0.92

474

319

467.4

18.4

233.7

9.2

6144LFPCBCYYY

*Replace YYY with fiber type:


010 = Singlemode
062 = 62.5/125 m Multimode
50E = 50/125 m multimode

www.te.com/adc

50U = 50/125 m Ultra multimode laser


optimized to 300 m
5U5 = 50/125 m Ultra multimode laser
optimized to 550 m

+1-952-938-8080

1-800-366-3891

394

Fiber Optic Cable Solutions


Compact BuildingTM Cable

TEs armored plenum compact building cables


are designed for use in backbone or horizontal
cabling applications. Constructions above 24
fibers are available with 12 fibers subgroups (up
to 144 fibers total).

Features

Compliances

Interlocking aluminum armor

Telcordia GR-409-CORE, EIA/TIA FOTPs

TrueNet Technology to improve cable


performance (up to 144 fibers)

TIA/EIA 568-B

Fiber Optic Cable Solutions

TrueNet Structured Cabling

Armored Plenum

(UL) 1666, NEC OFCR, FT-4

Constructions above 24 fibers feature 12


fiber subunits

Applications
Backbone distribution cabling
Industrial environments

11/11

102094AE

Raised floor installations

www.te.com/adc

+1-952-938-8080

1-800-366-3891

395

Fiber Optic Cable Solutions


Compact BuildingTM Cable
Armored Plenum

72 FIBEr CABLE
Plenum Inner and
Outer Jacket

Plenum Inner and


Outer Jacket

Interlocking
Aluminium Armor

Interlocking
Aluminum Armor

900 m Tight
Buffered Fiber

Rip Cord

Aramid Yarn
Strength Members

900 m Tight
Buffered Fiber

Dielectric Central
Strength Member

Aramid Yarn
Strength Members

Rip Cord

Dielectric Central
Strength Member
12 Fiber Subunit

ENvIrONMENTAL CHArACTErISTICS
Storage Temperature:
-40 to 70 C (-40 to 158 F)
Operating Temperature:
-20 to 70 C (-4 to 158 F)
Installation Temperature:
0 to 70 C (32 to 158 F)

MECHANICAL CHArACTErISTICS

Part Number

Diameter

Weight

Minimum Bend radius

Long Term

in

mm

in

lbf

lbf

135

290

11.6

145

5.8

1000

224

300

67

141

290

11.6

145

5.8

1000

224

300

67

150

290

11.6

145

5.8

1000

224

300

67

161

290

11.6

145

5.8

1800

403

600

135

240

161

290

11.6

145

5.8

1800

403

600

135

0.62

310

208

314

12.4

157

6.2

1800

403

600

135

0.87

449

302

442

17.4

221

8.7

2700

604

1000

224

24.6

0.97

628

422

492

19.4

246

9.7

2700

604

1000

224

6072LFPCBAYYY

25.9

1.02

710

477

518

20.4

259

10.2

2700

604

1000

224

6096LFPCBAYYY

29.7

1.17

778

523

594

23.4

297

11.7

2700

604

1000

224

6144LFPCBAYYY

32.2

1.27

987

663

644

25.4

322

12.7

2700

604

1000

224

102094AE

Short Term

mm

mm

in

6004LFPCBAYYY

14.5

0.57

201

6006LFPCBAYYY

14.5

0.57

210

6008LFPCBAYYY

14.5

0.57

223

6012LFPCBAYYY

14.5

0.57

240

6018LFPCBAYYY

14.5

0.57

6024LFPCBAYYY

15.7

6036LFPCBAYYY

22.1

6048LFPCBAYYY

www.te.com/adc

Kg/km lb/1000ft

Loaded

Maximum Pulling Load

TrueNet Structured Cabling

12 FIBEr CABLE

11/11

Fiber Optic Cable Solutions

Specifications

+1-952-938-8080

Installed

1-800-366-3891

396

Fiber Optic Cable Solutions


Compact BuildingTM Cable
Armored Plenum

Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

2001/5001

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Fast Ethernet
100Mbps

Gigabit Ethernet
1Gbps

10 Gigabit Ethernet
10Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/2000 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m1

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Multimode

Singlemode

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

Guaranteed Ethernet Transmission Performance

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

397

Fiber Optic Cable Solutions

102094AE

TrueNet Structured Cabling

Optical Performance

Fiber Optic Cable Solutions


Compact BuildingTM Cable
Armored Plenum
Ordering Information
mm

in

kg/km

lb/10001

Catalog Number*

14.5

0.57

201

135

6004LFPCBAYYY

14.5

0.57

210

141

6006LFPCBAYYY

14.5

0.57

223

150

6008LFPCBAYYY

12

14.5

0.57

240

161

6012LFPCBAYYY

18

14.5

0.57

240

161

6018LFPCBAYYY

24

15.7

0.62

310

208

6024LFPCBAYYY

36

22.1

0.87

449

302

6036LFPCBAYYY

48

24.6

0.97

628

422

6048LFPCBAYYY

72

25.9

1.02

710

477

6072LFPCBAYYY

96

29.7

1.17

778

523

6096LFPCBAYYY

144

32.2

1.27

987

663

6144LFPCBAYYY

*Replace YYY with fiber type:


010 = Singlemode
062 = 62.5/125 m multimode
50E = 50/125 m multimode/orange jacket
50U = 50/125 m ultra multimode laser optimized to 300 meters
5U5 = 50/125 m ultra multimode laser optimized to 550 meters
Note: Steel armor available by special quote

102094AE

TrueNet Structured Cabling

Fibers

Weight

11/11

Fiber Optic Cable Solutions

Diameter

www.te.com/adc

+1-952-938-8080

1-800-366-3891

398

Fiber Optic Cable Solutions


Compact Building Cable

Features

Applications

900 m tight buffered fibers designed


for one-pass mechanical stripping

Designed for use in backbone or


horizontal cable applications

Constructions above 24 fibers


feature subunits

Vertical cable runs from cross-connects


to telecommunication rooms

All-dielectric construction includes aramid


yarn tensile strength members

Vertical cable runs from telecommunication


rooms to consolidation points

Features AirES technology to improve


cable performance (up to 24 fibers)

Armored constructions are available.


Please contact your TE representative.

Compliances
Telcordia GR-409-CORE, EIA/TIA FOTP
standards
(UL) 1666, NEC OFNR, FT-4

Optical Performance

Multimode

11/11

102094AE

TIA/EIA 568-B

Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

2001/5001

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Singlemode

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

1
2

Ordering information follows on the next page.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

399

Fiber Optic Cable Solutions

TrueNet Structured Cabling

OFNR/FT-4 c(UL)us Riser Cable

Fiber Optic Cable Solutions


Compact Building Cable

OFNR/FT-4 c(UL)us Riser Cable

TrueNet Structured Cabling

72-Fiber Cable
PVC Outer Jacket

12-Fiber Subunit

900 m Tight
Buffered Fiber

PVC Outer Jacket


Aramid Yarn
Strength Member

Fiber Aramid Yarn


Strength Member

Rip Cord
900 m Tight
Buffered Fiber

Dielectric Central
Strength Member

Dielectric Central
Strength Member

Guaranteed Ethernet Transmission Performance


Fast Ethernet
100 Mbps

Gigabit Ethernet
1 Gbps

10 Gigabit Ethernet
10 Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/2000 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m1

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

Ordering Information
Fibers

Diameter

Weight

Minimum Bend radius

102094AE

Loaded

11/11

Fiber Optic Cable Solutions

12-Fiber Cable

Catalog Number*

Installed

mm

in

kg/km

lb/1000'

mm

in

mm

in

4.6

0.18

37

21

91.4

3.6

45.7

1.8

6004LFRCBCYYY

5.3

0.21

43

24

106.7

4.2

53.3

2.1

6006LFRCBCYYY

6.1

0.24

59

38

121.9

4.8

61.0

2.4

6008LFRCBCYYY

12

7.4

0.29

73

43

147.3

5.8

73.7

2.9

6012LFRCBCYYY

18

7.4

0.29

73

43

147.3

5.8

73.7

2.9

6018LFRCBCYYY

24

8.1

0.32

125

66

162.6

6.4

81.3

3.2

6024LFRCBCYYY

36

17.0

0.67

262

176

340.4

13.4

170.2

6.7

6036LFRCBCYYY

48

19.6

0.77

307

206

396.2

15.6

195.6

7.7

6048LFRCBCYYY

72

21.1

0.83

414

278

421.6

16.6

210.8

8.3

6072LFRCBCYYY

96

22.4

0.88

399

268

447.0

17.6

223.5

8.8

6096LFRCBCYYY

144
23.9
0.94
430
*Replace YYY with fiber type:
010 = Singlemode
062 = 62.5/125 m Multimode
50E = 50/125 m multimode

289

477.5

18.8

238.8

9.4

6144LFRCBCYYY

www.te.com/adc

50U = 50/125 m Ultra multimode lazer


optimized for 300 m
5U5 = 50/125 m Ultra multimode lazer
optimized for 550 m

+1-952-938-8080

1-800-366-3891

400

Fiber Optic Cable Solutions


Compact BuildingTM Cable

Features

Compliances

Interlocking aluminum armor

Telcordia GR-409-CORE, EIA/TIA FOTPs

TrueNet Technology to improve cable


performance (up to 144 fibers)

TIA/EIA 568-B

Fiber Optic Cable Solutions

TEs armored riser compact building cables are


designed for use in backbone or horizontal
cabling applications. Constructions above 24
fibers are available with 12 fiber subgroups
(up to 144 fibers).

(UL) 1666, NEC OFCR, FT-4

Constructions above 24 fibers feature 12


fiber subunits

Applications
Backbone distribution cabling
Raised floor installations
Industrial environments

11/11

102094AE

TrueNet Structured Cabling

Armored Riser

www.te.com/adc

+1-952-938-8080

1-800-366-3891

401

Fiber Optic Cable Solutions


Compact BuildingTM Cable
Armored Riser

72 FIBEr CABLE
OFNR Riser Inner
and Outer Jacket

OFNR Riser Inner


and Outer Jacket

Interlocking Armor

Interlocking Armor

900 m Tight
Buffered Fiber

Rip Cord
900 m Tight
Buffered Fiber

Aramid Yarn
Strength Members

Aramid Yarn
Strength Members

Dielectric Central
Strength Member

Dielectric Central
Strength Member
12 Fiber Subunit
with OFNR Jacket

ENvIrONMENTAL CHArACTErISTICS
Storage Temperature:
-40 to 70 C (-40 to 158 F)
Operating Temperature:
-20 to 70 C (-4 to 158 F)
Installation Temperature:
0 to 70 C (-32 to 158 F)

MECHANICAL CHArACTErISTICS

Part Number

Diameter

Weight

Maximum Pulling Load

Installed

Short Term

Long Term

in

mm

in

mm

in

lbf

lbf

14.5

0.57

198

133

290

11.6

145

5.8

1000

224

300

67

6006LFrCBAYYY

14.5

0.57

202

136

290

11.6

145

5.8

1000

224

300

67

6008LFrCBAYYY

14.5

0.57

223

150

290

11.6

145

5.8

1000

224

300

67

6012LFrCBAYYY

15.7

0.62

250

168

314

12.4

157

6.2

1800

403

600

135

6018LFrCBAYYY

15.7

0.62

250

168

314

12.4

157

6.2

1800

403

600

135

6024LFrCBAYYY

17.0

0.67

302

203

340

13.4

170

6.7

1800

403

600

135

6036LFrCBAYYY

25.9

1.02

650

437

518

20.4

259

10.2

2700

604

1000

224

6048LFrCBAYYY

28.4

1.12

740

497

568

22.4

284

11.2

2700

604

1000

224

6072LFrCBAYYY

29.7

1.17

868

583

594

23.4

297

11.7

2700

604

1000

224

6096LFrCBAYYY

31.0

1.22

918

617

620

24.4

310

12.2

2700

604

1000

224

6144LFrCBAYYY

32.2

1.27

929

624

644

25.4

322

12.7

2700

604

1000

224

102094AE

mm

6004LFrCBAYYY

www.te.com/adc

Kg/km lb/1000ft

Minimum Bend radius


Loaded

TrueNet Structured Cabling

12 FIBEr CABLE

11/11

Fiber Optic Cable Solutions

Specifications

+1-952-938-8080

1-800-366-3891

402

Fiber Optic Cable Solutions


Compact Building Cable
Armored Riser

Maximum Attenuation
(dB/km)

Typical Attenuation
(dB/km)

Guaranteed Minimum
bandwidth (MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

2001/5001

50/125 m

3.0/1.5

2.5/1.0

7001/5001

50/125 m ultra 300

3.0/1.5

2.5/1.0

20002/5001

50/125 m ultra 550

3.0/1.5

2.5/1.0

47002/5001

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

NA

Fast Ethernet
100Mbps

Gigabit Ethernet
1Gbps

10 Gigabit Ethernet
10Gbps

Multimode

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125 m

300 m/2 km

275 m/550 m

33 m/300 m1

50/125 m

300 m/2 km

750 m/2000 m

150 m/300 m1

50/125 m ultra 300

300 m/2 km

1100 m/550 m

300 m/300 m1

50/125 m ultra 550

300 m/2 km

1100 m/550 m

550 m/300 m1

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

2 km/NA

5 km/NA

10 km/40 km

Multimode

Singlemode

Bandwidth specified by overfilled launch (OFL)


Bandwidth specified by laser-based launch

Guaranteed Ethernet Transmission Performance

Singlemode

10 Gigabit Ethernet distance guarantees at 1300 nm are achieved via four 3.125 Gbps channels multiplexed with
WWDM technology (10GBASE-LX4)

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

403

Fiber Optic Cable Solutions

102094AE

TrueNet Structured Cabling

Optical Performance

Fiber Optic Cable Solutions


Compact Building Cable
Armored Riser
Ordering Information
Fibers

mm

in

kg/km

lb/10001

Catalog Number*

14.5

0.57

198

133

6004LFRCBAYYY

14.5

0.57

202

136

6006LFRCBAYYY

14.5

0.57

223

150

6008LFRCBAYYY

12

15.7

0.62

250

168

6012LFRCBAYYY

18

15.7

0.62

250

168

6018LFRCBAYYY

24

17.0

0.67

302

203

6024LFRCBAYYY

36

25.9

1.02

650

437

6036LFRCBAYYY

48

28.4

1.12

740

497

6048LFRCBAYYY

72

29.7

1.17

868

583

6072LFRCBAYYY

96

31.0

1.22

918

617

6096LFRCBAYYY

144

32.2

1.27

929

624

6144LFRCBAYYY

*Replace YYY with fiber type:


010 = Singlemode
062 = 62.5/125 m multimode
50E = 50/125 m multimode/orange jacket
50U = 50/125 m ultra multimode laser optimized to 300 meters
5U5 = 50/125 m ultra multimode laser optimized to 550 meters

102094AE

TrueNet Structured Cabling

Weight

11/11

Fiber Optic Cable Solutions

Diameter

www.te.com/adc

+1-952-938-8080

1-800-366-3891

404

Series 2 ................................................................... 414


NT System ............................................................... 433
89D Style ................................................................ 437
Building Entrance Terminals
Fiber Wall Boxes ...................................................... 450
Protection Devices ................................................... 461

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

405

Complementary Products

Voice Grade Solutions

102094AE

TrueNet Structured Cabling

Complementary Products

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Wired Termination Block System


Features

TrueNet Structured Cabling


102094AE

Can be custom configured to meet specific


application requirements
Available in 8- and 10-pair configurations
Unique center port design allows for
patching or testing without removing
cross-connect wires or disrupting the circuit

Series 2 10-pair disconnect block

Versatile mounting hardware allows


mounting on wall, in racks, etc.
Comprehensive labeling options

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

8-pair Series 2 block Quantity: 1


(order in multiples of 10)
Snaps into Type 85 rod mount bracket or
standard Type 85 back mount frame

0.88" x 4.88" x 1.63"


(22.35mm x 123mm x 41.4mm)

6036 1 005-00

10-pair Series 2 K110 disconnect block


Quantity per Pack: 10
Snaps into universal mounting system,
Type 105 rod mount bracket or standard
Type 105 back mount frame. Wires can be
terminated with either KRONE insertion tool
or industry-standard punchdown tool
equipped with 110-blade

0.88" x 4.88" x 1.63"


(22.35mm x 123mm x 41.4mm)

6468 5 102-00

10-pair Series 10 block Quantity: 1


(order in multiples of 10)
Snaps into Type 85 rod mount bracket

0.88" x 4.06" x 1.63"


(22.35mm x 103.1mm x 41.4mm)

6730 1 001-00

10-pair Series 10 block Quantity: 1


(order in multiples of 10)
Includes (20) 5mm spacers for even spacing
on Type 85 rod mount bracket

0.88" x 4.06" x 1.63"


(22.35mm x 103.1mm x 41.4mm)

6730 1 001-01

11/11

Voice Grade Solutions

Complementary Products

The original IDC termination block system

Tech Tip
For proper wire management, use the wire management rings on both sides of the block.
Pull half the jumpers or patch cords to one side and the other half to the other side.

Tech Tip
Field terminated kits are used for customized applications where preterminated blocks are not required.
Used with TE cable, the kits provide a complete broadband/DSL transmission solution.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

406

Complementary Products
Voice Grade Solutions: Series 2

Complementary Products

200-pair kit

Voice Grade Solutions

160-pair kit

200-pair rod mount kit

300-pair kit

Ordering information follows on the next page

11/11

102094AE

TrueNet Structured Cabling

Series 2 Field Assembly Kits

www.te.com/adc

+1-952-938-8080

1-800-366-3891

407

Complementary Products
Voice Grade Solutions: Series 2
Series 2 Field Assembly Kits
Ordering Information

TrueNet Structured Cabling

Catalog Number

18.44" x 4.06" x 3.81"


(468.38mm x 103.12mm x 96.77mm)

6636 1 210-00

200-pair field assembly kit Quantity: 1


Provides termination or patching for
multipurpose cable, including riser cable,
totaling up to 200 pairs; allows easy pair
identification in 10-pair groups. Includes
(2) 10-pair Series 2 blocks, (1) Type 105
label holder, (1) 21-position Type 105
back mount frame, mounting hardware,
protective rubber grommets for mounting
bracket rear cable entry holes

18.44" x 4.88" x 3.69"


(468.38mm x 123mm x 93.73mm)

6638 1 180-00

300-pair field assembly kit Quantity: 1


Includes (30) Series 2 10-pair blocks,
(1) 31-position back mount frame,
label holder, mounting hardware

27.13" x 4.88" x 3.69"


(689mm x 123mm x 93.73mm)

6638 1 300-03

200-pair field assembly kit Quantity: 1


Includes (20) Series 2 10-pair blocks,
(1) 21-position rod mount frame,
label holder, mounting hardware

18.63" x 4.88" x 3.69"


(473.2mm x 123mm x 93.73mm)

6638 1 180-21

102094AE

Dimensions (HxWxD)

160-pair field assembly kit Quantity: 1


Provides termination or patching for (4)
4-pair cables. Includes (20) 8-pair
Series 2 blocks, (1) Type 85 label holder, (1)
21-position Type 85 back mount frame,
mounting hardware, protective rubber
grommets for back mount frame rear
cable entry holes

11/11

Voice Grade Solutions

Complementary Products

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

408

Complementary Products
Voice Grade Solutions: Series 2

Complementary Products
168-pair block, factory preterminated

200-pair block, factory preterminated

300-pair block, factory preterminated

Voice Grade Solutions

160-pair block, factory preterminated

11/11

102094AE

TrueNet Structured Cabling

Series 2 Preterminated Assemblies

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

409

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Preterminated Assemblies


Ordering Information

TrueNet Structured Cabling


102094AE

Dimensions (HxWxD)

Catalog Number

160-pair factory preterminated kit Quantity: 1


18.44" x 4.06" x 3.81"
For PBX switch cables using only 16-pair
(468.38mm x 103.12mm x 96.77mm)
per Telco connector, or for IBM 3270
applications. Includes (20) 8-pair Series 2 blocks,
affixed to back mount frame, preterminated to
(10) RJ-21 50-pin male connectors with
hook-and-loop fastener locks. Wires divided into
16-pair groups. Each RJ-21 50-pin connector is
connected to (2) Series 2 blocks at the opposite end:
Pairs 1 to 8 terminate to first block; pairs 9 to 16
terminate to second block. Sequence repeated for
each 50-pin connector. Includes (1) Type 85
label holder

6635 1 210-08

168-pair factory preterminated kit Quantity: 1


18.44" x 4.06" x 3.81"
For PBX systems. Includes (21) 8-pair Series 2
(468.38mm x 103.12mm x 96.77mm)
blocks, affixed to back mount frame,
preterminated to (7) RJ-21 50-pin male connectors;
hook-and-loop fastener locks on each 50-pin
connector secure equipment cables. Wires divided
into 24-pair groups. Each group terminates to
(1) RJ-21 50-pin connector at one end and (3)
Series 2 blocks at the other end: Pairs 1 to 8
terminate to first block; pairs 9 to 16 terminate to
second block; pairs 17 to 24 terminate to third
block. Sequence repeated for each 50-pin connector

6635 1 220-03

200-pair factory preterminated kit


Series 2 blocks, male connectors Quantity: 1
For demarcation and multi-pair cable installations.
Includes (20) 10-pair Series 2 disconnect blocks
preterminated to (8) 25-pair male Telco RJ-21X
connectors* on a 21-position back mount frame;
includes (1) Type 105 label holder; hook-and-loop
fastener locks on each 50-pin connector secure
equipment cables. Mounts on mounting frame
or support bars

6637 1 180-03

18.44" x 4.88" x 3.69"


(468.38mm x 123mm x 93.73mm)

*25-pair Telco connectors are oriented for bottom feed cable assemblies

Ordering information continues on the next page

11/11

Voice Grade Solutions

Complementary Products

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

410

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Preterminated Assemblies

Catalog Number

18.44" x 4.88" x 3.69"


(468.38mm x 123mm x 93.73mm)

6637 1 180-04

300-pair factory preterminated kit with 10-pair


Series 2 blocks, male connectors Quantity: 1
For demarcation and multi-pair cable installations.
Includes (30) 10-pair Series 2 disconnect blocks
preterminated to (12) 25-pair male Telco RJ-21X
connectors on a 21-position back mount frame;
includes (1) Type 105 label holder; hook-and-loop
fastener locks on each 50-pin connector secure
equipment cables. Mounts on support bars

27.13" x 4.88" x 3.69"


(689mm x 123mm x 93.73mm)

6637 1 210-04

300-pair factory preterminated kit with 10-pair


Series 2 blocks, female connectors Quantity: 1
For demarcation and multi-pair cable installations.
Includes (30) 10-pair Series 2 disconnect blocks
preterminated to (12) 25-pair female Telco RJ-21X
connectors on a 21-position back mount frame;
includes (1) Type 105 label holder; hook-and-loop
fastener locks on each 50-pin connector secure
equipment cable. Mounts on support bars

27.13" x 4.88" x 3.69"


(689mm x 123mm x 93.73mm)

6637 1 210-10

*25-pair Telco connectors are oriented for bottom feed cable assemblies

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

411

Voice Grade Solutions

Dimensions (HxWxD)

200-pair factory preterminated kit with 10-pair


Series 2 blocks, female connectors Quantity: 1
For demarcation and multi-pair cable installations.
Includes (20) 10-pair Series 2 disconnect blocks
preterminated to (8) 25-pair female Telco RJ-21X
connectors* on a 21-position back mount frame;
includes (1) Type 105 label holder; hook-and-loop
fastener locks on each 50-pin connector secure
equipment cables. Mounts on mounting frame
or support bars

102094AE

TrueNet Structured Cabling

Description

Complementary Products

Ordering Information

Complementary Products
Voice Grade Solutions: Series 2

TrueNet Structured Cabling


102094AE

11/11

Voice Grade Solutions

Complementary Products

Series 2 Preterminated Blocks

200-pair preterminated block

300-pair preterminated block

Features
High-density IDC termination system
Preterminated to reduce installation time
Provides look-both-ways fault isolation, testing and qualification without removing wires
25-pair connectors oriented for top feed cable assemblies
Used with TE cable, the blocks provide a complete broadband/DSL transmission solution

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

200-pair block Quantity: 1


Preterminated to (8) 25-pair female
Telco RJ-21X connectors

18.44" x 4.88" x 3.69"


(468.38mm x 123mm x 93.73mm)

6637 1 180-49

300-pair block Quantity: 1


Preterminated to (12) 25-pair female
Telco RJ-21X connectors

27.13" x 4.88" x 3.69"


(689mm x 123mm x 93.73mm)

6637 1 210-14

www.te.com/adc

+1-952-938-8080

1-800-366-3891

412

Complementary Products
Voice Grade Solutions: Series 2

11/11

102094AE

Complementary Products

100-pair disconnect
block with top exit stub

200-pair disconnect block


with bottom rear exit stub

200-pair disconnect
block with rear exit stub

Ordering Information
Description
100-pair stubbed disconnect block
with ARMM cable Quantity: 1
Includes (10) 10-pair Series 2 disconnect blocks,
label holder, (1) 11-position back mount frame with
attached double group lug. Blocks preterminated to
100-pair ARMM (24 AWG) cable (15'); cable stub
exits through top of back mount frame
Mounts on support bars

Dimensions (HxWxD)

Catalog Number

9.63" x 4.88" x 3.69"


(244.6mm x 123mm x 93.73mm)

6637 1 140-30/15

200-pair stubbed disconnect block


18.44" x 4.88" x 3.69"
with ARMM cable Quantity: 1
(468.38mm x 123mm x 93.73mm)
Includes (20) 10-pair Series 2 disconnect blocks,
label holder, (1) 21-position back mount frame
with attached double ground lug. Blocks
preterminated to 200-pair ARMM (24 AWG)
cable; cable stub exits through either top or bottom
of assembly through rear cable entry holes on back
mount frame Mounts directly to mounting frame
or support bars
25' top rear exit stub
50' top rear exit stub
50' bottom rear exit stub
200-pair stubbed disconnect block
18.44" x 4.88" x 3.69"
with PVC cable stubs Quantity: 1
(468.38mm x 123mm x 93.73mm)
Includes (20) 10-pair Series 2 disconnect blocks,
label holder, (1) 21-position back mount frame.
Blocks preterminated to (8) 25-pair unshielded
PVC (24 AWG) cables (50'); cable stub exits through
rear cable exit holes on back mount frame
Mounts to mounting frame or support bars

www.te.com/adc

+1-952-938-8080

6637 1 250-01/25
6637 1 250-01/50
6637 1 250-02/50
6637 1 180-51/50

1-800-366-3891

413

Voice Grade Solutions

TrueNet Structured Cabling

Series 2 Stubbed Disconnect Blocks

Complementary Products
Voice Grade Solutions: Series 2

TrueNet Structured Cabling


102094AE

RJ48C
Eight 2-pair channels,
unstubbed

Twenty-eight 2-pair
channels, unstubbed

Twenty-eight 2-pair
channels, stubbed
RJ48X

Features
High-density wire termination system
Support 4-wire circuits such as T1 or HDSL
Disconnect blocks provide look-both-ways fault isolation, testing and qualification without removing wires
Provide RJ48X or RJ48C handoff for easy access and circuit labeling
Equipped with eight-position keyed modular jacks; pins 1, 2, 4 and 5 preterminated to 8-pair Series 2
blocks. When an RJ plug is removed, pin 1 shorts to pin 4 and pin 2 shorts to pin 5, via a shorting bar
located in the jack. Upon insertion of a plug, the shorts are removed
RJ48C versions can be used in conjunction with digital data jacks (smart jacks)
Versatile patching options for easy changes or testing
Preterminated blocks reduce installation time
Superior contact performance
Numerous labeling options
Variety of mounting options on wall, in racks or cabinets

11/11

Voice Grade Solutions

Complementary Products

Series 2 8-Pair Termination Block Systems

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

414

Complementary Products
Voice Grade Solutions: Series 2

Series 2 8-Pair Termination Block Systems


Ordering Information
(28) 2-pair channels with 8-position keyed
18.38" x 4.16" x 3.13"
modular jacks Quantity: 1
(466.9mm x 105.66mm x 79.5mm)
Used to terminate HDSL service or to breakout
T3 (DS3) circuit into (28) 2-pair channels. 8-position
keyed modular jack; pins 1, 2, 4 and 5 preterminated
to (7) 8-pair Series 2 blocks
RJ48X modular jacks, no cable stub

6635 1 140-27

RJ48C modular jacks, no cable stub

6635 1 140-29

RJ48X modular jacks, (2) 50' cable stub

6635 1 140-28/50

RJ48C modular jacks, (2) 50' cable stub

6635 1 140-30/50

(8) 2-pair channels with 8-position keyed


5.25" x 4.16" x 3.13"
modular jacks Quantity: 1
(133.35mm x 105.66mm x 79.5mm)
Used to terminate HDSL service or to breakout
T3 (DS3) circuit into (8) 2-pair channels. 8-position
keyed modular jack; pins 1, 2, 4 and 5 preterminated
to (2) 8-pair Series 2 blocks
RJ48X modular jacks, no cable stub

6635 1 140-31

RJ48C modular jacks, no cable stub

6635 1 140-32

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

415

Complementary Products

Catalog Number

Voice Grade Solutions

Dimensions (HxWxD)

102094AE

TrueNet Structured Cabling

Description

Complementary Products
Voice Grade Solutions: Series 2

TrueNet Structured Cabling


102094AE

11/11

Voice Grade Solutions

Complementary Products

Grounding Blocks

Ground clip

Type 105 grounding block

Series 2 ground kit

Ordering Information
Description
Type 105 grounding block Quantity: 1
Designed to provide common ground point for
shielded cable drain wires; earth lead allows
isolated ground connection. Snaps into Type 105
back mount frame or rod mount bracket.
NOTE: When used in rod mount bracket, ground
clips must be used (2 clips per block)
Termination:
38 drain wires: 20 AWG
76 drain wires: 22 to 26 AWG (2 per contact)
Color: Red
Earth lead: 9.84" (250mm), 16 AWG red
Ground clips Quantity: 1
Snap onto each end of 8- or 10-pair Series 2 rod
mount block to ground to rod mount bracket.
Allows installation of 10-pair protection magazine
when overvoltage protection is required
Series 2 rod mount/back mount
frame ground kit Quantity: 1
Kit includes (1) 10-pair hinged label holder,
(1) earth module capable of terminating 68 drain
wires (2 per contact). Remove standard 10-pair
block label holder and replace with earth module
and hinged label holder

www.te.com/adc

Dimensions (HxWxD)
0.88" x 4.88" x 1.56"
(22.35mm x 123mm x 39.6mm)

+1-952-938-8080

Catalog Number
6089 2 017-00

6089 3 202-00

6638 1 180-24

1-800-366-3891

416

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Accessories:
Category 5 Patch Cords for Series 2 Blocks

Pair No.
Pair 2 R
T
Pair 1 R
T
6647 2 762-XX

Pair No.
Pair 2 R
T
Pair 1 R
T
6647 2 753-XX

Pair No.
Pair 4 R
T
Pair 3 R
T
Pair 2 R
T
Pair 1 R
T

6647 2 750-XX
Wired to
Pin #
2
1
4
5

Pair No.
Pair 2 R
T
Pair 1 R
T
6647 2 782-XX

Wired to
Pin #
8
7
6
3
2
1
4
5

Pair No.
Pair 4 R
T
Pair 3 R
T
Pair 2 R
T
Pair 1 R
T

102094AE

6647 2 752-XX

11/11

TO P

6647 2 000-XX

12345678

Pair 1 R
T

TO P

Pair No.

Pair No.
Pair 4 R
T
Pair 3 R
T
Pair 2 R
T
Pair 1 R
T

6647 2 751-XX

Ordering Information
Description

Catalog Number*

Series 2 plug to Series 2 plug Quantity: 1


wired straight through, white cable
1-pair
2-pair
4-pair

6647 2 000-XX
6647 2 753-XX
6647 2 752-XX

Series 2 plug to RJ45 (8P4C) plug Quantity: 1


wired T568A, white cable
2-pair
4-pair

6647 2 762-XX
6647 2 750-XX

Series 2 plug to RJ45 (8P4C) plug Quantity: 1


wired T568B, white cable
2-pair
4-pair

6647 2 782-XX
6647 2 751-XX

*Replace XX with:

www.te.com/adc

04 = 4'
07 = 7'
10 = 10'

15 = 15'
25 = 25'
50 = 50'

+1-952-938-8080

1-800-366-3891

417

Voice Grade Solutions

Category 5 Series 2 patch cords

Wired to
Pin #
8
7
2
1
6
3
4
5

Complementary Products

Wired to
Pin #
6
3
4
5

12345678

TrueNet Structured Cabling

These patch cords are used in all Series 2 8-pair and 10-pair disconnect blocks and exceed Category 5
specifications for NEXT.

Complementary Products
Voice Grade Solutions: Series 2

TrueNet Structured Cabling


102094AE

Type 85 label holder

Type 105 label holder

Type 85 rod mount label holder

Type 85 label strip

Type 105 hinged closed

Type 105 hinged open

Type 85 closed

Type 85 open

Type 105 label strip, slotted

Side-mount label holder

11/11

Voice Grade Solutions

Complementary Products

Series 2 Accessories: Labeling for Series 2 Blocks

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

418

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Accessories: Labeling for Series 2 Blocks


Ordering Information

11/11

102094AE

Type 85 label holder Quantity: 1


Mounts onto Type 85 mounting bracket; each holder
requires 1 block position on a mounting bracket.
Large printable space allows groupings based on
application. Includes paper label, plastic carrier and
accepts label catalog number: 6631 3 100-04

Catalog Number

0.63" x 3.41" x 1.31"


(16mm x 86.6mm x 33.27mm)

6036 2 018-00

Type 85 rod mount label holder Quantity: 1


0.63" x 3.41" x 1.31"
Mounts onto Type 85 rod mount bracket; each holder (16mm x 86.6mm x 33.27mm)
requires 1 block position. Includes paper label, plastic
carrier and accepts label catalog number: 6631 3 100-02

6630 1 009-01

Type 85 hinged label holder Quantity: 1


Recommended for jumpered environments.
Snaps onto block face to provide hinged cover
over block termination contacts and patch/test ports.
Includes paper label, clear plastic protective cover
for each side of hinged cover and accepts label
catalog number: 6631 3 100-02. Cover flips up for
patching, cross-connecting, testing and monitoring

0.63" x 3.5" x 0.63"


(16mm x 88.9mm x 16mm)

6036 2 005-02

Side-mount label holder Quantity: 1


Mounts onto side of either 8- or 10-pair Series 2
blocks. 2 side-mount label holders attach to each
block; includes rectangular paper label with
each holder

0.63" x 1" x 0.31"


(16mm x 25.4mm x 7.9mm)

6462 2 016-00

Type 105 label holder Quantity: 1


Includes jumper rings on both sides for additional
wire management, paper label, plastic cover and
accepts labels catalog number: 6631 3 106-XX
Mounts onto Type 105 mounting bracket, Type
105 rod mount bracket or universal mounting
system mounting bracket in Type 105 position.
Each label holder requires one block position

0.81" x 5.63" x 1.31"


(20.57mm x 143mm x 33.27mm)

6630 2 004-05

Type 105 hinged label holder Quantity: 1


Recommended for jumpered environments. Snaps
onto block face to provide hinged cover over block
termination contacts and patch/test ports.
Includes paper label, clear plastic protective cover
for each side of hinged cover and accepts label
catalog number: 6631 3 100-03. Cover flips up for
patching, cross-connecting, testing and monitoring.
Extends 0.38" (9.7mm) from face of block

0.63" x 4.31" x 0.63"


(16mm x 109.47mm x 16mm)

6089 2 015-01

Type 105 slotted label strip Quantity per Pack: 10


Snaps onto face of 10-pair Series 2 block; covers
only top row of block and is fully visible with patch
cords in place. Includes one slide-in paper label
(Catalog Number: 6631 3 102-XX) or can be
written on directly

0.81" x 4.25" x 0.88"


(20.57mm x 107.9mm x 22mm)

6462 2 096-00

www.te.com/adc

+1-952-938-8080

1-800-366-3891

419

Complementary Products

Dimensions (HxWxD)

Voice Grade Solutions

TrueNet Structured Cabling

Description

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Accessories: Labeling for Series 2 Blocks

TrueNet Structured Cabling

Identifies

Orange

Demarcation point (e.g., central office terminations)

Green

Network connections (e.g., network and auxiliary equipment)

Purple

Common equipment, PBX, LANs, multiplexers (e.g., switching and data equipment)

White

First level backbone (e.g., main cross-connect [MC (campus distributer[CD])]


to a horizontal cross-connect [HC (floor distributer [FD])] or to an intermediate
cross-connect [IC (building distributer [BD])])

Gray

Second level backbone (e.g., IC [BD] to a HC [FD])

Blue

Horizontal cable (e.g., horizontal connections to telecommunications outlets; formerly


referred to as station cable)

Brown

Interbuilding backbone (campus cable terminations)


NOTE: Brown takes precedence over white or gray for interbuilding runs

Yellow

Miscellaneous (e.g., auxiliary, alarms, security)

Red

Reserved for future use (also, key telephone systems)

Based on ANSI/TIA/EIA-606-A, May 1, 2002

Label sheet for Type 85 rod


mount/hinged label strip

Label sheet for Type


85 label holder

Label sheet for Type 105


label strip

102094AE

Color

11/11

Voice Grade Solutions

Complementary Products

Examples of TIA/EIA-606 Color Coding

Label sheet for Type 105


label holder

Label sheet for Type 105


hinged label holder

Ordering information follows on the next page


www.te.com/adc

+1-952-938-8080

1-800-366-3891

420

Complementary Products
Voice Grade Solutions: Series 2

Series 2 Accessories: Labeling for Series 2 Blocks

11/11

102094AE

Catalog Number

Paper label sheet for Type 85 rod mount label holder


Labels come pre-cut on a white, 8.5" x 11" sheet, with 30 labels per sheet;
accommodate hand or laser printing Quantity: 1 sheet per package

6631 3 100-04

Paper label sheet for Type 85 label holder, hinged label holder or label strip
Labels come pre-cut on a white, 8.5" x 11" sheet, with 50 labels per sheet;
accommodate hand or laser printing Quantity: 1 sheet per package

6631 3 100-02

Paper label sheets in TIA/EIA-606 colors for Type 85 label holder, hinged label
holder or label strip Labels come pre-cut on an 8.5" x 11" sheet with 50 labels
per sheet; accommodate hand or laser printing Quantity: 1 sheet per package

6631 3 085-04

Paper label sheet for Type 105 hinged label holder


Labels come pre-cut on a white 8.5" x 11" sheet, with 50 labels per sheet;
accommodate hand or laser printing Quantity: 1 sheet per package

6631 3 100-03

Paper label sheets in TIA/EIA-606 colors for Type 105 hinged label holder
Labels come pre-cut on an 8.5" x 11" sheet with 50 labels per sheet; accommodate
hand or laser printing Quantity: 1 sheet per package

6631 3 105-XX*
Not available in
-05 (brown)
-06 (yellow)
-07 (red)
-08 (white)

Paper label sheet for Type 105 label holder


Labels come pre-cut on a white 8.5" x 11" sheet, with 26 labels per sheet;
accommodate hand or laser printing Quantity: 1 sheet per package

6631 3 106-XX*

Paper label sheet for Type 105 label strip


Labels come perforated on an 8.5" x 11" sheet, 20 labels per sheet; accommodate
hand or laser printing. Available in all TIA/EIA-606 specified colors, two colors per
sheet (one color on each side) Quantity: 1 sheet per package
Orange, red

6631 3 102-01/09

Green, purple

6631 3 102-02/03

White, blue

6631 3 102-04/06

Gray, brown

6631 3 102-05/07

Yellow, white

6631 3 102-08

*Replace XX with:
00 = orange
01 = green
02 = purple
03 = gray
04 = blue
05 = brown
06 = yellow
07 = red
08 = white

www.te.com/adc

+1-952-938-8080

1-800-366-3891

421

Complementary Products

Description

Voice Grade Solutions

TrueNet Structured Cabling

Ordering Information

Complementary Products
Voice Grade Solutions: Series 2

Winged test adapter

Signature device

8-pair disconnect bar

10-pair disconnect bar

Cable clamp

Look-both-ways test cord

Bridging test cord

One-pair site-mounted test cord

102094AE

TrueNet Structured Cabling

Flat-top dummy plug

Disconnect plug

Ground clip

Marking caps

11/11

Voice Grade Solutions

Complementary Products

Series 2 Accessories

Dust cover, 200-pair

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

422

Complementary Products
Voice Grade Solutions: Series 2
Series 2 Accessories
Ordering Information

11/11

102094AE

Dimensions (HxWxD)

Disconnect plug Quantity: 1


(order in multiples of 100)
Color-coded plastic plugs plug into
disconnect block to open a pair of contacts. Center
hole for attaching ID tabs. Green only

Catalog Number

Flat-top dummy plugs Quantity: 1


(order in multiples of 100)
Color-coded, plastic dummy plugs designed to plug
into disconnect block for quick identification of
special circuits and to block port access. Surface for
writing or attaching small adhesive stickers
(not supplied). Center hole for attaching ID tabs
Red

6417 3 105-00

White

6417 3 105-01

Blue

6417 3 105-07

Marking caps Quantity: 1


(order in multiples of 100)
Color-coded, plastic marking caps designed
to snap over a block pair for quick identification
of special circuits. Caps block access to prevent
accidental removal of jumper wires, but do not
interfere with patching
Red

6089 3 006-00

White

6089 3 006-01

Blue

6089 3 006-07

Ground clips Quantity: 1


Snap onto each end of 8- or 10-pair Series 2 rod
mount block to ground to rod mount bracket.
Used with connect-style blocks, allowing installation
of 10-pair protection magazine when secondary
protection is required

6089 3 202-00

Cable clamp Quantity: 1


Used to ground 10-pair Series 2 block. Fits on back
of 10-pair rod mount blocks to provide tie-off point
for cable foil on braided shield

0.5" x 0.81"
(12.7mm x 20.64mm)

6619 3 011-00

0.13" x 2.88" x 1"


(22.23mm x 73.15mm x 25.4mm)

6418 3 405-00

Disconnect bars Quantity: 1


Plug into disconnect blocks to open all contacts
simultaneously. For cutover and other applications
requiring numerous service disconnects. Made of
plastic. Extend 0.44" (11.11mm) from face of block
8-pair disconnect bar

Ordering information continues on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

423

Complementary Products

6089 3 055-02

Voice Grade Solutions

TrueNet Structured Cabling

Description

Complementary Products
Voice Grade Solutions: Series 2
Series 2 Accessories
Ordering Information

TrueNet Structured Cabling

17.75" x 5" x 2.75"


(451mm x 127mm x 69.85mm)

Catalog Number
6638 2 000-00

Winged test adapter Quantity: 1


Allows monitoring of circuit without disruption in
Series 2 blocks

6646 2 928-00

Signature device Quantity: 25


Provides ability to remotely sectionalize subscriber
line fault to either the customer or network side of
installation site by bridging line at the customer's
premises with voltage-level and voltage-polarity
sensitive resistance. Provides signature for CO test
equipment, even with customer side unterminated

6647 1 010-00

Test Cords
Series 2 bridging test cord, 1-pair with 2
banana plugs Quantity: 1
Used to test parallel to the circuit. Two banana
plugs connect to test equipment

6646 2 900-XX*

Series 2 look-both-ways test cord Quantity: 1


Isolates cable side from jumper side
for look-both-ways testing
1-pair with 4 banana plugs

6647 2 900-XX*

1-pair with 4 alligator clips

6647 2 906-XX*

Series 2 1-pair site-mounted test cord Quantity: 1


Monitor or look-both-ways test circuit with flip
of a switch. Mounts on 1 position of back mount
frame or directly a wall. Includes RJ11 jack to quickly
isolate feeder or distribution network problems

6645 2 125-XX*

*Replace XX with:
01 = 1'
04 = 4'
07 = 7'
10 = 10'

102094AE

Dimensions (HxWxD)

200-pair dust cover Quantity: 1


Protects (20) 10-pair Series 2 blocks. Greater depth
to clear overvoltage protection magazines or other
devices. Allows approximately 1.25" (31.75mm)
clearance from face of block

11/11

Voice Grade Solutions

Complementary Products

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

424

Complementary Products
Voice Grade Solutions: NT System
NT Termination Block System

Features
100% compliant with Telcordia TR-NWT001195
UL 94V-0 plastic
Available in disconnect, switching, connect
contact styles
>200 IDC reterminations guaranteed

NT connect block

NT marking cap

NT hinged label holder


(closed)

NT hinged label holder


(open)

>750 test cord insertions guaranteed


21% vertical space saving compared to Series 2
Prevents accidental access to cable side contact
during cross-connect work
Wire diameter range for solid and stranded
copper conductors
- 2 conductors per contact
(same diameter) 22-26 AWG
- 1 conductor per contact
22-26 AWG

11/11

NT label holder
NT switching block

NT disconnect block

NT disconnect plug

NT back mount frame

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

425

Complementary Products

The NT mounting pitch of 0.69-inch (17.5mm) represents a vertical space saving of over 21 percent
compared to standard Series 2 installations. Cable pairs are terminated with the KRONE insertion tool
and a full line of accessories is available.

Voice Grade Solutions

The cable side (feed) contacts on the NT block are situated at a right angle on the back side of the
block. After the cable side contacts have been terminated and the blocks installed, access to the cable
side contacts is blocked, preventing accidental access to these contacts.

102094AE

TrueNet Structured Cabling

Like the Series 2 termination block system, the NT system features 45-degree angled silver-plated
contacts, built-in test ports and insulation clamping ribs to protect the termination against vibration
and mechanical stresses.

Complementary Products
Voice Grade Solutions: NT System
NT Termination Block System
Ordering Information

TrueNet Structured Cabling


102094AE

Catalog Number

10-pair NT disconnect block Quantity: 1 (order in multiples of 10)


Normally closed contact. Snaps into NT back mount frame

7014 1 004-03

10-pair NT footprint ground block Quantity: 1 (order in multiples of 10)


Terminates up to 20 drain wires. Snaps into NT back mount frame

7014 1 005-00

NT to Series 2 adapter Quantity: 1


Accepts any standard single pair Series 2 test cord for NT testing

7014 1 014-00

Black NT dummy plug Quantity: 1 (order in multiples of 100)


Inserts into test/patch port of NT block for quick
identification of special circuits. Plugs block access to pair
and prevent accidental removal of jumper wires

7014 3 049-00

Red NT marking caps Quantity: 1 (order in multiples of 100)


Snaps over block pair for quick identification of special circuits.
Blocks access to pair and prevents accidental removal of jumper wires

6196 3 042-00

Red NT disconnect plug Quantity: 1 (order in multiples of 100)


Insert into patch/test port of NT block to open (disconnect) circuit

7014 3 021-00

NT 10-pair hinged label holder Quantity: 1


Snaps onto 10-pair NT block face to provide hinged cover
over block termination contacts and patch/test ports. Includes
label for each side of hinged cover, clear plastic protective
cover. Cover flips up for testing, patching, cross-connection

7014 2 007-00

NT 10-pair label holder Quantity: 1


Requires 1 block position on NT back mount frame. Includes
compartment for storing dummy plugs, marking caps, disconnect plugs

7014 2 006-00

NT 1-pair site mounted test cord Quantity: 1


Mounts on 1 position of back mount frame or directly on wall

6645 2 126-XX 1

NT 1-pair "look-both-ways" test cord Quantity: 1


XXX = length of test cord in feet
001 = 0.3 m (1') 004 = 1.2 m (4'),
007 = 2.1 m (7') 010 = 3 m (10')

ANP-12NBAS-XXX

NT changeover adapter Quantity: 1 (Order in multiples of 10)


1

7014 1 044-00

Replace XX with:
01 = 1'
04 = 4'
07 = 7'
10 = 10'

11/11

Voice Grade Solutions

Complementary Products

Description

Ordering information continues on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

426

Complementary Products
Voice Grade Solutions: NT System
NT Termination Block System
Ordering Information

20-position NT back mount frame Quantity: 1


200-pair capacity; includes space for label holder
Solid back
Cable entry holes (1.75" diameter: 1.5" with
protective rubber grommet)
30-position NT back mount frame Quantity: 1
300-pair capacity; includes space for label holder
Solid back
Cable entry holes (1.75" diameter: 1.5" with
protective rubber grommet)

6655 2 850-05
6655 2 851-05

6655 2 850-10
6655 2 851-10

6655 2 850-20
6655 2 851-20

6655 2 850-30
6655 2 851-30

Voice Grade Solutions

10-position NT back mount frame Quantity: 1


100-pair capacity; includes space for label holder
Solid back
Cable entry holes (1.75" diameter: 1.5" with
protective rubber grommet)

Complementary Products

Catalog Number

5-position NT back mount frame Quantity: 1


50-pair capacity; includes space for label holder
Solid back
Cable entry holes (1.75" diameter: 1.5" with
protective rubber grommet)

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

427

Complementary Products
Voice Grade Solutions: Accessories

TrueNet Structured Cabling


102094AE

KRONE insertion tool


Inhibitor Lock
Prevents the automatic trimming of
excess wire to enable daisy-chaining

Blade
Used to remove termination
blocks from back mount frames

Hook
Used to grab and remove
wires for changes

Features
Insertion sensor ensures the conductor is fully inserted into the block contacts before allowing any
excess wire to be cut off
An inhibitor lock prevents the scissors from operatingparticularly useful in applications in which
conductors are daisy-chained through several contacts
Universal scissors cut a variety of cable types, including 20 AWG through 26 AWG and Type 1
foam-insulated conductors
Specially designed wire hook removes terminated conductors
Blade helps to remove blocks easily from back mount frames

11/11

Voice Grade Solutions

Complementary Products

LSA Plus Insertion Tool

Ordering Information
Description

Catalog Number

Insertion tool Quantity: 1

6417 2 055-01

Disposable tool Quantity: 1


Terminates wire into contact, will not cut excess wire; snips required to cut off excess wire

6417 3 006-01

www.te.com/adc

+1-952-938-8080

1-800-366-3891

428

Complementary Products
Voice Grade Solutions: 89D Style

11/11

102094AE

Complementary Products

5-pair block

50-pair block

25-pair block

Features
Upgrade from 66-type technology
Unique center port allows monitoring and look-both-ways testing without disturbing IDC
Double the density at the demarcation point
Available in traditional 25- and 50-pair increments
Fits 89D-style mounting brackets
Preterminated blocks available with a range of connector styles and positioning options
The K110 feature enables the termination of wire with either the KRONE insertion tool or any industry-standard punchdown tool with a 110 blade. Please note, the 5-pair disconnect block is not K110 compatible.

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

25-pair disconnect block assembly Quantity: 1


Field-terminated disconnect block; snaps into
89D bracket; includes label for empty half

10" x 3.38" x 1.38"


(254mm x 85.85mm x 35.05mm)

6639 1 003-01

50-pair disconnect block assembly Quantity: 1


Field-terminated disconnect block; snaps into
89D bracket; includes label and label holder

10" x 3.38" x 1.38"


(254mm x 85.85mm x 35.05mm)

6652 1 880-10

2" x 2" x 1.25"


(50.8mm x 50.8mm x 31.8mm)

6585 2 002-00

5-pair disconnect block Quantity: 1


Field-terminated disconnect block; mounts
directly to wall or in an enclosure.
This block is not K110 compatible

www.te.com/adc

+1-952-938-8080

1-800-366-3891

429

Voice Grade Solutions

TrueNet Structured Cabling

89D Style 25-Pair and 50-Pair Termination Blocks and Assemblies

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 25-Pair Blocks

TrueNet Structured Cabling

Features
Used at demarcation points
25-pair block preterminated to 25-pair female
Telco connector for customer interface
Mounts to wall or in mounting frame
Quantity: 1

25-pair disconnect block


with Telco connector

Ordering Information
Description
25-pair disconnect block with 25-pair
female Telco (RJ-21X) connector

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 003-02

25-Pair Disconnect Block with RJ-71C


Features
For applications in which telephone service is provided in
conjunction with apartment building door answering system

102094AE

11/11

Voice Grade Solutions

Complementary Products

25-Pair Disconnect Block with 25-Pair


Female Telco (RJ-21X) Connector

Provides 12-line series connection with door answering system


Shorting plug provided to test loop continuity or to bypass the
answering system
Mounts to wall or in mounting frame
Quantity: 1
25-pair disconnect block
with RJ-71C connector

Ordering Information
Description

Dimensions (HxWxD)

25-pair disconnect block with RJ-71C

www.te.com/adc

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

+1-952-938-8080

Catalog Number
6639 1 003-04

1-800-366-3891

430

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 25-Pair Blocks

Complementary Products

25-pair disconnect block


with 8 RJ48X connectors

Features
Connects T1 lines and other 4-wire circuits
The RJ48X is an 8-position keyed modular jack. Pins 1, 2, 4 and 5 are preterminated to the disconnect block.
When RJ plug is removed, pin 1 shorts to pin 4 and pin 2 shorts to pin 5 via a shorting bar located in the
jack. When a plug is inserted, the shorts are removed
For shielded cable applications, pins 7 and 8 of the jack are also pretermintaed to the block (slate and brown
conductors) so a common drain wire connection can be maintained throughout the circuit
Mounts to wall or in mounting frame
Quantity: 1

Ordering Information
Description
25-pair disconnect block
with 8 RJ48X connectors

Dimensions (HxWxD)
10" x 3.38" x 2.88"
(254mm x 85.85mm x 73mm)

Catalog Number
6639 1 003-03

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

431

Voice Grade Solutions

RJ48X

102094AE

TrueNet Structured Cabling

25-Pair Disconnect Block with 8 RJ48X Connectors

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 25-Pair Blocks

TrueNet Structured Cabling

R1

T1

Connects T1 lines and other 4-wire circuits


The RJ48S is an 8-position keyed modular
jack with pins 1, 2, 7 and 8 preterminated
to the disconnect block
RJ48S

Mounts to wall or in mounting frame


Quantity: 1

25-pair disconnect block with


12 RJ48S connectors

Ordering Information
Description
25-pair disconnect block with 12
RJ48S connectors

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 003-05

25-Pair Disconnect Block with 12 RJ48C Connectors


Features
Connects T1 lines and other 4-wire circuits
The RJ48C is an 8-position keyed modular
jack with pins 1, 2, 4 and 5 preterminated
to the disconnect block
Mounts to wall or in mounting frame

RJ48C

Quantity: 1

Ordering Information

102094AE

Features

Description

11/11

Voice Grade Solutions

Complementary Products

25-Pair Disconnect Block with 12 RJ48S Connectors

25-pair disconnect block


with 12 RJ48C connectors

www.te.com/adc

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 003-18

+1-952-938-8080

1-800-366-3891

432

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 25-Pair Blocks

102094AE

Connects T1 lines and other 4-wire circuits


The RJ48S is an 8-position keyed modular jack
with pins 1, 2, 7 and 8 preterminated to the
disconnect block
25-pair female Telco (RJ-21X) connector is
preterminated to the disconnect block,
eliminating the need for field termination
Mounts to wall or in mounting frame

25-pair disconnect block


with 12 RJ48S connectors
and Telco connector

Quantity: 1

Ordering Information
Description
25-pair disconnect block with 12 RJ48S
and 25-pair female Telco (RJ-21X) connector

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 003-07

25-Pair Disconnect Block with 12 RJ14C and


25-Pair Female Telco (RJ-21X) Connector
R1 T1
T2
R2

Features
Used for bridged connections to the tip and
ring conductors of 2 separate telephone lines

1 2 3 4 5 6

The RJ14C is a 6-position modular jack with


pins 2, 3, 4 and 5 preterminated to the
disconnect block

RJ14C

The 25-pair female Telco (RJ-21X) connector


is preterminated to the disconnect block,
eliminating the need for field termination
Mounts to wall or in mounting frame

25-pair disconnect block


with 12 RJ14C connectors
and Telco connector

Quantity: 1

11/11

Complementary Products

Features

Ordering Information
Description
25-pair disconnect block with 12 RJ14C
and 25-pair female Telco (RJ-21X) connector

www.te.com/adc

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 003-06

+1-952-938-8080

1-800-366-3891

433

Voice Grade Solutions

TrueNet Structured Cabling

25-Pair Disconnect Block with 12 RJ48S and


25-Pair Female Telco (RJ-21X) Connector

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 50-Pair Blocks

TrueNet Structured Cabling


102094AE

Custom Configurations

Front view showing side mounting options

01

02

03

Configuration/01: Connectors
top left, bottom right
04

05

06

Configuration/02: Both
connectors on left side

Features

Rear view showing rear mounting options

Used at demarcation points


Disconnect block is preterminated to (2) 25-pair female
or male Telco (RJ-21X) connectors for customer interface
Includes 89D bracket, hook-and-loop fastener locks,
label and label holder
50

51

52

53

Blocks can be custom configured: Use chart on this page,


substituting the 2-digit number for 01 at the end of the
catalog number
Mounts directly to wall or in mounting frames
Quantity: 1

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number

50-pair disconnect block with (2) 25-pair female


Telco (RJ-21X) connectors

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 051-02/01

50-pair disconnect block with (2) 25-pair male


Telco (RJ-21X) connectors

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 050-02/01

11/11

Voice Grade Solutions

Complementary Products

50-Pair Disconnect Block with (2) 25-Pair Telco (RJ-21X) Connectors

Tech Tip
When wiring 50-pair blocks with 4-pair data cable, you do not need to skip every fifth pair for patching
purposes. In a jumpered environment, terminate all 25 pairs on each side.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

434

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 50-Pair Blocks

11/11

102094AE

The RJ48X is an 8-position keyed modular jack


with pins 1, 2, 4 and 5 preterminated to the
disconnect block. When RJ plug is removed, pin
1 shorts to pin 4 and pin 2 shorts to pin 5 via a
shorting bar located in the jack. When a plug is
inserted, the shorts are removed

RJ48X

Mounts directly to wall or in mounting frames


Quantity: 1

50-pair disconnect block with


16 RJ48X connectors

Ordering Information
Description
50-pair disconnect block
with 16 RJ48X connectors

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 050-32

50-Pair Disconnect Block with 16 RJ48X Connectors


Modified for Shielded Applications
Features
Connects T1 lines and other 4-wire circuits
The RJ48X is an 8-position keyed modular jack with pins 1, 2, 4 and 5 preterminated to the
disconnect block
For shielded cable applications, pins 7 and 8 of the jack are preterminated to the block (slate and brown
conductors) so a common drain wire connection can be maintained throughout the circuit
Mounts directly to wall or in mounting frames
Quantity: 1

Ordering Information
Description
50-pair disconnect block with 16 RJ48X
connectors modified for shielded applications

www.te.com/adc

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 050-33

+1-952-938-8080

1-800-366-3891

Complementary Products

Features

Voice Grade Solutions

TrueNet Structured Cabling

50-Pair Disconnect Block with 16 RJ48X Connectors

435

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 50-Pair Blocks

TrueNet Structured Cabling


102094AE

Features
Connects T1 lines and other 4-wire circuits
The RJ48C is an 8-position keyed modular
jack with pins 1, 2, 4 and 5 preterminated
to the disconnect block
Mounts directly to wall or in mounting frames

RJ48C

Quantity: 1

Ordering Information
Description
50-pair disconnect block
with 16 RJ48X connectors

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 050-44

50-Pair Disconnect Block with 12 RJ45 Connectors


R1 T1
T3
R3
R2
T4
T2
R4

Features
The RJ45 is an 8-position keyed modular
jack with pins 5, 4, 1, 2, 3, 6, 7 and 8
(wired TIA 568-B) preterminated to the
disconnect block

1 2 3 4 5 6 7 8

Includes label and label holder

T568B

Mounts directly to wall or in mounting frames


Quantity: 1
50-pair disconnect block
with 12 RJ45 connectors

Ordering Information
Description

11/11

Voice Grade Solutions

Complementary Products

50-Pair Disconnect Block with 16 RJ48C Connectors

50-pair disconnect block


with 12 RJ45 connectors

www.te.com/adc

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73mm)

6639 1 052-01

+1-952-938-8080

1-800-366-3891

436

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 50-Pair Blocks

Complementary Products

Features
Incoming cable pairs are preterminated to
ARMM (24 AWG, CMR) cable
15-foot cable stub exits through top
of 89D bracket
Includes label and label holder
Quantity: 1
50-pair disconnect block
with ARMM stub

Ordering Information
50-pair disconnect block with ARMM Stub15'

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73.15mm)

6639 1 056-01/15

Voice Grade Solutions

Description

50-Pair Disconnect Block with ARMM Stub


and (2) 25-Pair Male Telco (RJ-21X) Connectors
Features
Incoming cable pairs are preterminated to ARMM
(24 AWG, CMR) cable
20-foot cable stub exits through top of 89D bracket
Two 25-pair male Telco (RJ-21X) connectors are preterminated to the
disconnect block, eliminating need for field termination
Includes label and label holder
Quantity: 1
50-pair disconnect block with
ARMM stub and connectors

11/11

102094AE

TrueNet Structured Cabling

50-Pair Disconnect Block with ARMM Stub

Ordering Information
Description
50-pair disconnect block with ARMM stub
and (2) 25-pair male Telco (RJ-21X) connectors.
Cable stub: 20'

www.te.com/adc

Dimensions (HxWxD)

Catalog Number

10" x 3.38" x 2.88"


(254mm x 85.85mm x 73.15mm)

6639 1 056-00/20

+1-952-938-8080

1-800-366-3891

437

Complementary Products
Voice Grade Solutions: 89D Style

89D Style Preterminated 50-Pair Blocks with Stubs

TrueNet Structured Cabling

900-pair disconnect frame with ARMM stub

Features
Incoming cable pairs of each block are preterminated to a 600- or 900-pair
ARMM (24 AWB, CMR) cable
Cable stubs exit through bottom of frame
Frame is equipped with (18) 50-pair disconnect blocks mounted
on 89D brackets
Includes label holders and labels

102094AE

Mounts directly to wall or in standard 35.5" (901.7mm) equipment rack

11/11

Voice Grade Solutions

Complementary Products

Disconnect Frame with ARMM Stub

Ordering Information
Description

Dimensions (HxWxD)

600-pair disconnect frame with ARMM stub

Catalog Number

23" x 23" x 7"


(584mm x 584mm x 178mm)

with 25' ARMM stub

6639 1 600-00/25

with 50' ARMM stub

6639 1 600-00/50

900-pair disconnect frame with ARMM stub

23" x 35" x 7"


(584mm x 889mm x 178mm)

with 25' ARMM stub

6639 1 900-00/25

with 50' ARMM stub

6639 1 900-00/50

www.te.com/adc

+1-952-938-8080

1-800-366-3891

438

Complementary Products
Voice Grade Solutions: 89D Style
89D Style Mounting Frames

Complementary Products
35.5" wide mounting frame for
25- and 50-pair block systems
19" wide mounting frame for
25- and 50-pair block systems

Ordering Information
Description

Dimensions (HxWxD)

19" mounting frame Quantity: 1


Supports up to (10) 25- or 50-pair blocks on
89D brackets. Equipped with 6 jumper rings
for cross-connect wire and/or patch cord routing
Without 89D brackets

6652 2 104-00

102094AE

With (10) 89D brackets

11/11

Catalog Number

26.38" x 19.25" x 6.5"


(670mm x 589mm x 159mm)

6652 2 104-10

23" mounting frame Quantity: 1


Supports up to (12) 25- or 50-pair blocks on
89D brackets. Equipped with 7 jumper rings
for cross-connect wire and/or patch cord routing

26.38" x 23" x 6.5"


(670mm x 589.6mm x 159mm)

Without 89D brackets

6652 2 108-00

With (12) 89D brackets

6652 2 108-12

35.5" mounting frame Quantity: 1


Supports up to (18) 25- or 50-pair blocks on
89D brackets. Equipped with 10 jumper rings
for cross-connect wire and/or patch cord routing

26.38" x 35.5" x 6.5"


(670mm x 901.7mm x 159mm)

Without 89D brackets

6652 2 105-00

With (18) 89D brackets

6652 2 105-18

www.te.com/adc

+1-952-938-8080

1-800-366-3891

439

Voice Grade Solutions

TrueNet Structured Cabling

These mounting frames are for 25-pair and 50-pair block systems only.
They are specifically designed to accept 89D type brackets.

Complementary Products
Voice Grade Solutions: 89D Style

TrueNet Structured Cabling

50-pair label holder

Clear dust cover


(shown on 50-pair block)

Hinged dust cover


(closed)

Hinged dust cover


(right side open)

89D bracket

102094AE

Ordering Information

11/11

Voice Grade Solutions

Complementary Products

89D Style Termination Block Accessories

Description

Dimensions (HxWxD)

Catalog Number

9.88" x 0.88"
(250.9mm x 22.4mm)

6639 3 019-00

10.06" x 2.5" x 1.38"


(255.5mm x 63.5mm x 35.05mm)

6586 3 004-00

9.75" x 2.13"
(247.65mm x 54.1mm)

6639 3 019-01

Hinged dust cover Quantity: 1


Designed for 50-pair block; left and right
sides swing open independently for access;
labeling areas inside both sides of cover;
includes 2 snap-in legs and covers
Color: orange

10.06" x 2.5" x 1.38"


(255.5mm x 63.5mm x 35.05mm)

6639 2 004-00

89D bracket for 25- and 50-pair blocks


Quantity: 1
Standard 89D stand-off bracket mounts
to mounting frame or directly to wall

10" x 3.38" x 1.5"


(254mm x 85.85mm x 38.1mm)

6639 3 016-00

50-pair block center mount label holder


Quantity: 1
Snaps into center section of 50-pair block
to cover cable side terminations
Clear dust cover Quantity: 1
Clear, protective plastic dust cover snaps over
50-pair block. Accepts adhesive paper label strip
Paper labeling strip for 50-pair dust cover
Quantity: 1

www.te.com/adc

+1-952-938-8080

1-800-366-3891

440

Complementary Products
Voice Grade Solutions: 89D Style

Ordering Information
Description

Catalog Number

Disconnect plug Quantity: 1 (order in multiples of 100)


Color-coded plastic plugs plug into disconnect block to open a pair of contacts.
Center hole for attaching ID tabs. Green only

6089 3 055-02

Flat-top dummy plugs Quantity: 1 (order in multiples of 100)


Color-coded, plastic dummy plugs designed to plug into disconnect block for quick
identification of special circuits and to block port access. Surface for writing or
attaching small adhesive stickers (not supplied). Center hole for attaching ID tabs
Red

6417 3 105-00

White

6417 3 105-01

Blue

6417 3 105-07

11/11
www.te.com/adc

+1-952-938-8080

1-800-366-3891

441

Complementary Products

Flat-top dummy plug

Voice Grade Solutions

Disconnect plug

102094AE

TrueNet Structured Cabling

89D Style Termination Block Accessories

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

6-Port

12-Port

Features and Benefits


Integrated splice tray offers flexible splice
management for individual or mass splicing
Sealed enclosure protect fibers from dust, water
spray, insects and other contaminants
Dual-hinged design ensures separation of
owner/client network segments

24-Port

NEMA-12 Rated
Tested to GR-2898-CORE

48-Port

Front and rear layer maximizes wall space


utilization for both splicing and interconnect
Robust steel construction protects fibers against
damage and ensures network reliability
Slotted cable entrance ports allow for rapid
cable installation and pass-through capability
Cable management and routing limits bend
radius and adds strain relief
216-Tool (can wrench), key lock or padlock
offers flexible security options

102094AE

TrueNet Structured Cabling

TE's OmniReach Indoor Fiber Distribution


Terminal (iFDT) provides Multiple Dwelling Unit
(MDU) applications with a compact and secure
family of enclosures by connecting fiber cables
at MDUs. The IFDT products are designed to
splice and terminate fibers in a range of sizes
including 6, 12, 24, and 48 fibers.

11/11

Building Entrance Terminals

Complementary Products

Indoor Fiber Distribution Terminal

www.te.com/adc

+1-952-938-8080

1-800-366-3891

442

Complementary Products
IFDT-12

IFDT-24

IFDT-48

12

24

48

Parking Adapters

12

24

48

Splice Trays

1/12f

1/12f

4/12f

8/12f

Grip Clamps

Jumper Ports

NEMA Rating

12

12

12

12

Height

7.0 in. (17.8 cm)

8.0 in. (20.3 cm)

18.5 in. (47.0 cm)

32.0 in. (81.3 cm)

Width

12.0 in. (30.5 cm)

14.0 in. (35.5 cm)

13.0 in. (33.0 cm)

13.0 in. (33.0 cm)

Depth

3.0 in. (7.6 cm)

5.0 in. (12.7 cm)

5.0 in. (12.7 cm)

5.0 in. (12.7 cm)

Color

CO White

CO White

CO White

CO White

Catalog Number
FDT- __ __ __ __ __ __ __ __

Complementary Products

IFDT-6
Fibers

Stub Length
Enclosure Type

Max Capacity

Code

Desc.

w/Prkg

w/o Prkg

IFDT-6/12

6-Fiber

12-Fiber

IFDT-12/24

12-Fiber

24-Fiber

IFDT-24/48

24-Fiber

48-Fiber

IFDT-48/96

48-Fiber

96-Fiber

0 Feet

025

25 Feet

100

100 Feet

200

200 Feet

300

300 Feet

500

500 Feet

Pigtails

SC/APC

Bare Rbn Pgtl Assy

Pigtails (Colored)

Stubs

Splice Tray
No Tray

Ribbon OSP w/Conn

Heat Shrink Fusion

Ribbon IFC w/Conn

Mechanical/Ribbon

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

Fiber Count
06

6 Fiber

12

12 Fibers

24

24 Fibers

48

48 Fibers

96

96 Fibers

www.te.com/adc

Pigtails
P

Pigtails (2mm)

No Pigtails

Parking

+1-952-938-8080

Parking

No Parking

1-800-366-3891

443

Building Entrance Terminals

000

Cable Type

Connector Type

11/11

102094AE

TrueNet Structured Cabling

Building Entrance Terminals: Fiber Wall Boxes

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

TrueNet Structured Cabling

Features
12-Packs provide for high-density
terminations and conserve wall space
Integrated splice tray offers flexible splice
management for individual or mass splicing
Sealed enclosure protect fibers from dust,
water spray, insects and other contaminants
Dual-hinged design ensures separation of
owner/client network segments
Designed to NEMA-12
Designed to GR-2898-CORE
Front and rear layer maximizes wall space utilization for both splicing and interconnect
Robust steel construction protects fibers
against damage and ensures network
reliability
Slotted cable entrance ports allow for rapid
cable installation and pass-through capability
Cable management and routing limits bend
radius and adds strain relief
216-Tool (can wrench), key lock or padlock
offers flexible security options

102094AE

The TE Indoor Fiber Distribution Terminal (IFDT)


series provides Customer Premises Equipment
applications with a compact and secure family
of enclosures for connecting fiber cables within
building entrance locations, communication
closets, computer rooms and other indoor
environments. The IFDT products are designed
to splice and terminate fibers in a range of sizes
including 6, 12, 24, 48, 72, and 96 fibers.

11/11

Building Entrance Terminals

Complementary Products

Indoor Fiber Distribution Terminal

www.te.com/adc

+1-952-938-8080

1-800-366-3891

444

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

IFDT-24

IFDT-48

IFDT-72

IFDT-96

Fibers (nominal)

6 and 12

24

48

72

96

Adapter Panels

2 APLH

2 APLH

4 APLH

6 APLH

8 APLH

Splice Trays

1/12f

2/12f

4/12f

6/12f

8/12f

Cable Ports

2 slotted

4 slotted

4 slotted

4 slotted

4 slotted

Grip Clamps

Jumper Ports

2 slotted

2 slotted

2 slotted

2 slotted

2 slotted

NEMA Rating

12

12

12

12

12

Height

7.0 in.
(17.8 cm)

8.0 in.
(20.3 cm)

18.5 in.
(47.0 cm)

24.5 in.
(62.2 cm)

32.0 in.
(81.2cm)

Width

12.0 in.
(30.5 cm)

14.0 in.
(35.5 cm)

13.0 in.
(33.0 cm)

13.0 in.
(33.0 cm)

13.0 in.
(33.0 cm)

Depth

3.0 in.
(7.6 cm)

5.0 in.
(12.7 cm)

5.0 in.
(12.7 cm)

5.0 in.
(12.7 cm)

5.0 in.
(12.7 cm)

Weight (Empty)

5.0 lbs
(2.3 kg)

7.0 lbs
(15.4 kg)

12.8 lbs (28.2


kg)

16.0 lbs
(35.2 kg)

20.0 lbs
(44 kg)

Color

CO White

CO White

CO White

CO White

CO White

Complementary Products

IFDT-12

Catalog Number
FDT- __ __ __ __ N X __ __
Stub Length

Enclosure Type/Capacity

000

0 Feet

IFDT-12

12 Fiber

IFDT-24

24 Fiber

025

25 Feet
100 Feet

IFDT-48

48 Fiber

100

IFDT-72

72 Fiber

200

200 Feet

IFDT-96

96 Fiber

300

300 Feet

500

500 Feet

Connector Type
N

SC/UPC

SC/APC

Cable Type
Pigtails

Splice Tray
0

No Tray

Heat Shrink Fusion

Mechanical/Ribbon

6 Fiber

12

12 Fiber

24

24 Fiber

48

48 Fiber

72

72 Fiber

96

96 Fiber

www.te.com/adc

Bare ribbon pigtail assy

Pigtails (Colored)

Stubs

Fiber Count
06

+1-952-938-8080

Ribbon OSP w/Conn

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

1-800-366-3891

445

Building Entrance Terminals

11/11

102094AE

TrueNet Structured Cabling

Specifications

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

TrueNet Structured Cabling

Features and Benefits


Accommodates smaller fiber counts; 6-, 12- and
24-fiber
Eliminates need for transitional NEMA box that
provides for mini-ducts
Liquid tight fittings offer cost savings
Aesthetic benefits to MDU building owners
Supplied with parking, pigtails and splice tray
Wall-mount; efficient use of wall space
Cable termination and splicing
Complete connector access
Lockable 216 tool/padlock offers flexible
security options

Environmental enclosure provides heavy-duty


protection from wind, dust, rain, and other
contaminants
Aluminum welded construction provides strength
and resists corrosion
Lightweight structure provides for easy
installation
Cable entrance ports seal cable at entry
Cable management and routing limits radius and
adds strain relief
Standard stub lengths of 100, 300, 500, and
1000 feet

102094AE

The Outdoor Fiber Distribution Terminals 24 are


designed to terminate, splice and interconnect
fiber optic cables in an outdoor environment.
This terminal may be adapted to Fiber-to-ThePremise (FTTP) Multiple Dwelling Unit (MDU)
applications and is particularly suited for garden
style MDU buildings. The enclosure is mounted
to the exterior surface of a dwelling and
connects the distribution cable and drops routed
to individual living units. The cables meet at a
central connector field that includes termination
for the distribution cable and parking for the
drop cables. The cabinet may be configured with
splice trays for splicing the cable to connector
pigtails. The OFDT-24 may be pre-terminated
on the distribution side with outside plant cable
stubs so that the unit is quickly connected to
the plant. The OFDT-24 may also be pre-wired
with pigtails on the drop side so that individual
drops routed into the unit can be spliced to the
connectorized pigtails.

11/11

Building Entrance Terminals

Complementary Products

Outdoor Fiber Distribution Terminal 24 (OFDT-24)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

446

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

Height:
Width:
Depth:
Weight (Empty):
Fiber Terminations:
Parking Adapters:
Splice Trays:
Cable Ports:
Color:

Ordering Information
Catalog Number
FDT- __ __ __ __ __ __ __ __ __ __ __

Enclosure
G

Stub Length

OFDT-24

000

Connector Type
J

SC/APC

Splice Tray

0 Feet

025

25 Feet

100

100 Feet

200

200 Feet

300

300 Feet

500

500 Feet

Cable Type

No Tray

Pigtails

Heat Shrink Fusion

Mechanical/Ribbon

Bare Ribbon Pigtail


Assembly

Pigtails (Colored)

Fiber Count
06

Stubs

6 Fiber

12 12 Fibers
24 Fibers

24

11/11

Complementary Products

13.5" (35.0 cm)


19.0" (49.0 cm)
8.0" (20.0 cm)
14 lbs (31 kg)
6, 12, 24
6, 12, 24
3
2 in bottom; 1 in rear
Beige

Parking
P

Parking

No Parking

www.te.com/adc

Ribbon OSP w/Conn

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

Pigtails

+1-952-938-8080

Pigtails (2mm)

No Pigtails

1-800-366-3891

447

Building Entrance Terminals

102094AE

TrueNet Structured Cabling

Specifications

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

TrueNet Structured Cabling

Features and Benefits


Environmental enclosure provides heavy-duty
protection from wind, rain, and other
contaminants
Aluminum welded construction provides strength
and resists corrosion
Flexible design accommodates 24 and 48 fibers
including termination and parking

Lightweight structure provides for easy


installation
Lockable tool or padlock offers flexible security
options
Cable entrance ports seal cable at entry
Cable management and routing limits radius and
adds strain relief

102094AE

The TE Outdoor Fiber Distribution Terminal 48F


(oFDT-48) is designed to terminate, splice
and interconnect fiber optic cables in an outdoor
environment. This terminal may be adapted to
Fiber-to-The-Premise (FTTP) Multiple Dwelling
Unit (MDU) applications by mounting the
enclosure to the exterior surface of a dwelling
and connecting between the distribution cable
and drops routed to individual living units. The
oFDT-48 is typically divided into two side-by-side
sections with distribution cable routed into one
side and drop cable routed into the other side.
The cables meet at a central connector field
that includes termination for the distribution
cable and parking for the drop cables. Each
side of the cabinet may be configured with
splice trays for splicing the cable to connector
pigtails. The oFDT-48 may be pre-terminated on
the distribution side with outside plant cable
stubs so that the unit is quickly connected to
the plant. The oFDT-48 may be pre-wired with
pigtails on the drop side so that individual
drops routed into the unit can be spliced to the
connectorized pigtails.

11/11

Building Entrance Terminals

Complementary Products

Outdoor Fiber Distribution Terminal 48 (oFDT-48)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

448

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

Ordering Information
Catalog Number
FDT- __ __ __ __ __ __ __ __ __ __ __

Pigtails
Enclosure

Pigtails (2mm)

No Pigtails

OFDT-48

Cable Type

Connector Type
J

Pigtails

SC/APC

Bare Ribbon Pigtail Assembly

Pigtails (Colored)

Stubs

Splice Tray
0

No Tray

Heat Shrink Fusion

Mechanical/Ribbon

Ribbon OSP w/Conn

Ribbon IFC w/Conn

Loose Tube OSP w/Conn

Loose Tube IFC w/Conn

Fiber Count
24

24 Fibers

48

48 Fibers

Stub Length
000

0 Feet

025

25 Feet

Parking

100

100 Feet

Parking

200

200 Feet

No Parking

300

300 Feet

500

500 Feet

www.te.com/adc

+1-952-938-8080

1-800-366-3891

449

Building Entrance Terminals

11/11

Complementary Products

oFDT-48
22.0 in (56 cm)
20.0 in (51 cm)
10.0 in (25 cm)
21.0 lbs (46 kg)
Up to 48
12, 24 or 48
1 to 4/side
2 on bottom
Beige

Height
Width
Depth
Weight (Empty)
Fiber Terminations
Parking Adapters
Splice Trays
Cable Ports
Color

102094AE

TrueNet Structured Cabling

Specifications

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes


Fiber Splitter Box (FSB)

TrueNet Structured Cabling


102094AE

These wall boxes provide a small footprint for splitting, splicing and terminating and are environmentally
rated for indoor or outdoor use. Available in three sizes, each box is equipped with a 12-fiber splice tray
allowing for an input splicing option. FSBs accept standard plug and play (PNP) splitters (same as in the
Fiber Distribution Hub 3000 or FDH 3000) and splitters can be easily added after the wall box has been
installed. FSBs accommodate 1x4, 1x8, 1x16 and 1x32 splitters; up to 72 fibers.

FSB-16 - Indoor/Outdoor Enclosure

Features and Benefits


Accommodates up to 16 ports
Rated for indoor or outdoor use
Traditional swing frame design allows for
access to the back section of the wall box
Splitter can be easily installed after wall box
install
Standard 12-fiber splice tray allows for input
splicing option

Specifications
Installation Type:
Fiber Count (Full):
Parking Ports:
Splitter/WDM Ports:
Splice Trays:
NEMA Rating:
Height:
Width:
Depth:

Indoor/Outdoor
16
0
1
1/12f
4 and 12
9"
9"
3.5"

Output pigtails can either be stored internally


or routed externally for MDU-ONT
connection
Accepts standard PNP splitter
(same as FDH 3000)

11/11

Building Entrance Terminals

Complementary Products

TEs OmniReach Fiber Splitter Box (FSB) enables customers to accelerate their FTTX deployments more
effectively and is an ideal solution when deploying FTTX networks in non-residential Multiple Tenant
Unit (MTU) and residential Multiple Dwelling Unit (MDU) applications.

www.te.com/adc

+1-952-938-8080

1-800-366-3891

450

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

Dual hinge design creates separation between rear


splitter section and front customer side access
Splitters can be easily installed after wall box install
allowing for separate purchase
Standard 12-fiber splice tray allows for input
splicing option
Accommodates up to 32 splitter ports for one
splitter modulel
Dual hinge provides small footprint on the wall while
maintaining excellent hand access to connectors

Complementary Products

Features and Benefits

Specifications
Installation Type:
Fiber Count (Full):
Parking Ports:
Splitter/WDM Ports:
Splice Trays:
NEMA Rating:
Height:
Width:
Depth:

Indoor
32
0
1
1/12f
12
8"
13"
5"

Accepts standard PNP splitter (same as FDH 3000)

FSB-72 - Outdoor Enclosure

Features and Benefits


Traditional swing frame design allows for access
to the back section of the wall box
Splitter can be easily installed after wall box install
Standard 12-fiber splice tray allows for input
splicing option
Accommodates up to 3 PNP splitter modules
72 port capacity with built-in 32-port parking
Easily wall mounts to buildings

Specifications
Installation Type:
Fiber Count (Full):
Parking Ports:
Splitter/WDM Ports:
Splice Trays:
NEMA Rating:
Height:
Width:
Depth:

Outdoor
72
32
3
5/12f
4
13"
19"
10"

Accepts standard PNP splitter (same as FDH 3000)

www.te.com/adc

+1-952-938-8080

1-800-366-3891

451

Building Entrance Terminals

11/11

102094AE

TrueNet Structured Cabling

FSB-32 - Indoor Enclosure

Complementary Products

Building Entrance Terminals: Fiber Wall Boxes

Catalog Number
FSB- __ __ __ __ __ __ __ __ __ __ __
3

9 10 11

11 Key Locks

1 Configuration
Standard

2 Enclosure Type
Code

Description

Capacity

Size (HxWxD)

Indoor FSB-32

32-Fiber

8"x13"x5"

Outdoor FSB-72

72-Fiber

13"x19"x8"

Indr/Outdr FSB-16 16-Fiber

9"x9"x3.5"

SC/APC

4 Splice Tray (Feeder Side)


2

Heat Shrink Fusion

Mechanical/Ribbon

No Splice Tray

12 12 Fibers
16 16 Fibers
32

32 Fibers

48

48 Fibers

72 72 Fibers

None Installed

1x32 Standard

1x16 Standard

2x32 Standard Power

1x8 Standard

Dual 1x8 Standard

Dual 1x16 Standard

1x4 Standard

2x16 Standard

Dual 1x4 Standard

One (1) Installed

Two (2) Installed

Three (3) Installed

Front Lock 1, Rear Lock 1

Front Lock 1, Rear Lock 2

Front Lock 1, No Rear Lock

Rear Lock 2, No Front Lock

No Stub

2 Fibers

4 Fibers

6 Fibers

8 Fibers

000

0 Feet

025

25 Feet

100

100 Feet

200

200 Feet

300

300 Feet

500

500 Feet

Adapters
0

Adapters Only
(No Pigtail for Feeder)

Pigtails
A

Splice Ribbon Pigtail


Assy

Splice Pigtails (900


Micron)

Stubs

None

8 Cable Type (Feeder Cable)

7 Splitter Qty Installed


0

None (Pad Lock Ready)

9 Feeder Cable Length

6 Splitter Type Installed

5 Fiber Count (Distribution)

10 Feeder Fiber Count

3 Connector Type

102094AE

TrueNet Structured Cabling

11/11

Building Entrance Terminals

Complementary Products

Ribbon IFC Cable

Loose Tube OSP Cable

Loose Tube IFC Cable

900um IFNR Cable

www.te.com/adc

+1-952-938-8080

Ribbon OSP Cable

1-800-366-3891

452

Complementary Products

Building Entrance Terminals: Protection Devices

100-pair 5-pin protection only


building entrance terminal with
top and bottom stubs

50-pair 5-pin protection


building entrance terminal

Features
High-density primary protection allows up to eighteen (double-sided) 100-pair units to be mounted in a standard 7-foot, 19-inch rack
26 AWG cable stub is provided for splicing to the incoming 24 AWG cable
Building entrance terminals available with 5-pin protectors in 25-, 50- and 100-pair units
5-pin protectors are rated 300 volts
Allow look-both-ways testing and monitoring without removing wires or protection
Numerous labeling options allow comprehensive marking

Building Entrance Terminals

11/11

Complementary Products

25-pair 5-pin protection


building entrance terminal

Variety of mounting hardware options


UL 497 listed
100% compliant with Telcordia TR-NWT-000937

102094AE

TrueNet Structured Cabling

High-Density 5-Pin Protection

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

453

Complementary Products

Building Entrance Terminals: Protection Devices

TrueNet Structured Cabling


102094AE

11/11

Building Entrance Terminals

Complementary Products

High-Density 5-Pin Protection

100-pair 5-pin protection


building entrance terminal with
bottom entrance stub

Ordering Information
Description

Dimensions (HxWxD)

Catalog Number*

25-pair 5-pin protection building terminal,


bottom entrance stub Quantity: 1

8.75" x 6" x 4.88"


(222.3mm x 152.4mm x 123.9mm)

6649 1 110-01/XX

50-pair 5-pin protection building entrance


terminal, bottom entrance stub Quantity: 1

14" x 6" x 4.88"


(355.6mm x 152.4mm x 123.9mm)

6649 1 210-01/XX

100-pair 5-pin protection building entrance


terminal, bottom entrance stub Quantity: 1

19.88" x 6.06" x 4.88"


(505mm x 153.9mm x 123.9mm)

5-pin protectors included

6649 1 310-01/XX

5-pin protectors included; (4) 25-pin Telco


(RJ-21X) connectors mounted on back for
fast installation

6649 1 313-01/XX

100-pair 5-pin protection building entrance


terminal, top entrance stub Quantity: 1

19.88" x 6.06" x 4.88"


(505mm x 153.9mm x 123.9mm)

100-pair 5-pin protection building entrance


terminal, bottom rear entrance stub
Quantity: 1

19.88" x 6.06" x 4.88"


(505mm x 153.9mm x 123.9mm)

6649 1 310-03/XX

5-pin protectors included

6649 1 310-02/XX

5-pin protectors included; (4) 25-pin Telco


(RJ-21X) connectors mounted on back for
fast installation

6649 1 313-02/XX

100-pair 5-pin protection building entrance


terminal, top rear entrance stub
Quantity: 1

19.88" x 6.06" x 4.88"


(505mm x 153.9mm x 123.9mm)

6649 1 310-04/XX

100-pair 5-pin protection building entrance


terminal, protection only, bottom and top
stubs Quantity: 1

10.75" x 6.06" x 2.75"


(2273.1mm x 153.9mm x 69.85mm)

6649 1 316-05/XX

*Replace XX with:
25 = 25'
50 = 50'

www.te.com/adc

+1-952-938-8080

1-800-366-3891

454

Complementary Products

Building Entrance Terminals: Protection Devices

100-pair indoor enclosed 5-pin building


entrance terminal with doors open

100-pair 5-pin indoor enclosed


building entrance terminal with doors
closedwith RJ-21X output shown

Features

Complementary Products

TrueNet Structured Cabling

5-Pin Indoor and Outdoor Enclosed Building Entrance Terminals

5-pin protection devices safeguard valuable cable plant and equipment from voltage surges and spikes
Lockable metal enclosure with Telco override cover and a splicing chamber with the choice of either
710 or MS2 splice connectors
5-pin protectors are rated 300 volts
10-pair Series 2 disconnect block output field provided for cross-connection, look-both-ways testing
and monitoring without removing wires or protectors
25-pair female Telco (RJ-21X) connectors available on indoor units
Lightweight, compact and fully stackable
Instructions, template and mounting hardware included to mount the terminal directly to a wall
UL 497 listed
100% compliant with Telcordia TR-NWT-000937

Building Entrance Terminals

Ordering information follows on the next page

11/11

102094AE

MS2 is a registered trademark of 3M

www.te.com/adc

+1-952-938-8080

1-800-366-3891

455

Complementary Products

Building Entrance Terminals: Protection Devices


5-Pin Indoor and Outdoor Enclosed Building Entrance Terminals
Ordering Information

TrueNet Structured Cabling


102094AE

11/11

Building Entrance Terminals

Complementary Products

Description

Dimensions (HxWxD)

25-pair indoor enclosed 5-pin building


entrance terminal Quantity: 1

Catalog Number

7.5" x 15.5" x 5.4"


(190.50mm x 393.7mm x 137.2mm)

710 splice connector input and RJ-21X


optional output

6649 1 430-09

MS2 splice connector input and RJ-21X


optional output

6649 1 470-09

25-pair outdoor enclosed 5-pin building


entrance terminal Quantity: 1

11.35" x 10.65" x 6.08"


(288.29mm x 270.15mm x 154.43mm)

710 splice connector input

6649 1 720-00

MS splice connector input

6649 1 760-00

50-pair indoor enclosed 5-pin building


entrance terminal Quantity: 1

11.25" x 15.63" x 5.38"


(285.75mm x 397mm x 136.65mm)

710 splice connector input

6649 1 530-00

MS splice connector input

6649 1 570-00

710 splice connector input and RJ-21X


optional output

6649 1 530-09

MS2 splice connector input and RJ-21X


optional output

6649 1 570-09

50-pair outdoor enclosed 5-pin building


entrance terminal Quantity: 1

13.88" x 19.63" x 6.38"


(352.55mm x 499mm x 162mm)

710 splice connector input

6649 1 820-00

MS2 splice connector input

6649 1 860-00

100-pair indoor enclosed 5-pin building


entrance terminal Quantity: 1

11.25" x 18.25" x 5.38"


(285.75mm x 463.55mm x 136.65mm)

710 splice connector input

6649 1 630-00

MS2 splice connector input

6649 1 670-00

710 splice connector input and RJ-21X


optional output

6649 1 630-09

MS2 splice connector input and RJ-21X


optional output

6649 1 670-09

100-pair outdoor enclosed 5-pin building


entrance terminal Quantity: 1

13.88" x 19.63" x 6.38"


(352.55mm x 499mm x 162mm)

710 splice connector input

6649 1 920-00

MS2 splice connector input

6649 1 960-00

Other configurations available; please contact TE Technical Assistance Center


MS2 is a registered trademark of 3M

www.te.com/adc

+1-952-938-8080

1-800-366-3891

456

Complementary Products

Building Entrance Terminals: Protection Devices

Complementary Products

50-pair magazine protection


building entrance terminal bottom
entrance stub

25-pair magazine protection


building entrance terminal bottom
entrance stub

100-pair magazine protection


building entrance terminal bottom
entrance stub

Features
High-density primary protection
Solid-state protection devices safeguard valuable cable plant and equipment from voltage
surges and spikes
Protector units are solid-state (320V median voltage rating) and equipped with individual fail-safe devices
Wall or rack mount magazine protection building entrance terminals for protection of 25-,
50- and 100-pairs
Each building entrance terminal equipped with solid-state protectors and a 26 AWG stub cable for
splicing to the incoming 24 AWG cable, providing a built-in fuse link
A 10-pair connector block (gray) field holds the protection magazines; connect block field is internally
wired with 24 AWG cable to the disconnect block field
A 10-pair disconnect block (white) field is provided for cross-connection, patching, look-both-ways
testing, circuit monitoring, circuit disconnecting and marking without having to remove the protection
magazines or wires
Available with stubs that exit through the bottom, top or rear of the terminal
UL 497 listed
10-pair protection magazine assemblies snap into 10-pair blocks
100% compliant with Telcordia TR-NWT-000937
Mounting hardware is included for mounting directly to a wall or on back mount frames or support bars

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

457

Building Entrance Terminals

11/11

102094AE

TrueNet Structured Cabling

10-Pair Magazine Protection

Complementary Products

Building Entrance Terminals: Protection Devices


10-Pair Magazine Protection

Dimensions (HxWxD)
6.25" x 5.75" x 5.06"
(158.75mm x 146.05mm x 128.52mm)

Catalog Number*
6659 1 025-32/XX

9.81" x 5.75" x 5.06"


(249.17mm x 146.05mm x 128.52mm)

6637 1 320-18/XX

18.56" x 5.75" x 5.06"


(471.42mm x 146.05mm x 128.52mm)
6637 1 320-19/XX
6659 1 132-87/XX
6659 1 132-48/XX

*Replace XX with:
25 = 25'
50 = 50'
Other configurations available; please contact TE Technical Assistance Center

102094AE

TrueNet Structured Cabling

Description
25-pair magazine protection building
entrance terminal, bottom entrance stub
Quantity: 1
50-pair magazine protection building
entrance terminal, bottom entrance stub
Quantity: 1
100-pair magazine protection building
entrance terminal
Quantity: 1
Bottom entrance stub
Bottom rear entrance stub
Top entrance stub

11/11

Building Entrance Terminals

Complementary Products

Ordering Information

www.te.com/adc

+1-952-938-8080

1-800-366-3891

458

Complementary Products

Building Entrance Terminals: Protection Devices

100-pair indoor enclosed magazine


building entrance terminal with doors
closedRJ-21X output shown
100-pair indoor enclosed magazine building entrance
terminal with doors open

Complementary Products

TrueNet Structured Cabling

10-Pair Magazine Protection Indoor and Outdoor


Enclosed Building Entrance Terminals

Features
Enclosed 10-pair magazine protection building entrance terminals for the overvoltage
protection of 100 pairs
Protector units are solid-state (320 volt median voltage rating) and equipment with individual
fail-safe devices
Lockable metal enclosure with Telco override cover, a splicing chamber with the choice of either
710 or MS2 splice connectors and a ground strap
10-pair connect block field holds the protection magazines
10-pair Series 2 disconnect block output field provided for cross-connection, look-both-ways
testing and monitoring without removing wires or protectors
Lightweight, compact and fully stackable
Instructions, template and mounting hardware included to mount the terminal directly to a wall

Building Entrance Terminals

UL 497 listed
100% compliant with Telcordia TR-NWT-000937
MS2 is a registered trademark of 3M

11/11

102094AE

25-pair female Telco (RJ-21X) connectors available on indoor units

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

459

Complementary Products

Building Entrance Terminals: Protection Devices


10-Pair Magazine Protection Indoor and Outdoor
Enclosed Building Entrance Terminals

Dimensions (HxWxD)
11.25" x 18.25" x 5.38"
(285.75mm x 463.55mm x 136.65mm)

Catalog Number

6659 1 132-77
6659 1 132-78
6659 1 132-79
6659 1 132-80

Other configurations available; please contact TE Technical Assistance Center


MS2 is a registered trademark of 3M

102094AE

TrueNet Structured Cabling

Description
100-pair indoor enclosed 10-pair magazine
building entrance terminal
Quantity: 1
710 splice connector input
MS2 splice connector input
710 splice connector input and RJ-21X
optional output
MS2 splice connector input and RJ-21X
optional output

11/11

Building Entrance Terminals

Complementary Products

Ordering Information

www.te.com/adc

+1-952-938-8080

1-800-366-3891

460

Complementary Products

Building Entrance Terminals: Protection Devices

Complementary Products

The 10-pair solid-state protection magazine with fail-safe is a high-density protection solution, providing
primary overvoltage protection. The magazine is loaded with 320V solid-state protectors and snaps into
Series 2 10-pair connect or disconnect termination modules. The three-chip balanced solid-state device
meets balance requirements of GTS 8700 and GR 974. It is UL 497 listed.

Solid-state protector with fail-safe

10-pair magazine, 10-pair system

Specifications
10-pair system

Median voltage rating:


Peak off-state voltage:
Switching voltage:
On-state voltage:
Leakage current:
Switching current:
On-state current:
Holding current:
Off-state capacitance:
Peak pulse current @2x10s:
Peak pulse current @8x20s:
Peak pulse current @10x160s:
Peak pulse current @10x560s:
Peak pulse current @10x1000s:

320V
270V
350V
8V
5A
800mA
2.2A
150mA
60pF
250A
250A
150A
100A
80A

Mounting
hardware

10-pair connect block

10-pair solid-state protection magazine

Ordering Information
Description
10-pair solid state magazine with fail safe
Quantity: 1
320V primary overvoltage protection; assembly
consists of (1) 10-pair protection magazine fully
loaded with (1) 320V solid-state protectors.
Snaps into 10-pair connect or disconnect blocks
mounted in grounded back mount frame
Extends 1.25" (31.75mm) from face of block

Dimensions (HxWxD)

Catalog Number

0.88" x 4.44" x 1.88"


(22.23mm x 112.8mm x 47.8mm)

6659 2 053-09

Solid-state protector with fail-safe,


Quantity: 1
320V nominal clamping voltage; inserts into
10-pair protection magazine

www.te.com/adc

+1-952-938-8080

6659 2 060-03

1-800-366-3891

461

Building Entrance Terminals

11/11

102094AE

TrueNet Structured Cabling

10-Pair Protection Magazine with Fail-Safe

Complementary Products

Building Entrance Terminals: Protection Devices

TrueNet Structured Cabling

The open contact feature offers additional security. If a protection device is removed, the circuit is
opened and the outside cable is automatically disconnected from the inside wire.

25-pair, single-pair system

50-pair, single-pair system

100-pair, single-pair system

102094AE

The ComProtect single-pair protector system is a solid-state system that features an open contact
design. The open contact design provides additional security because the circuit remains open until a
single-pair protection device is inserted. Single-pair protectors are available in a variety of voltages, and
are conveniently packaged in groups of ten with a ground bar. This system uses a switching block with
a normally open contact design.

11/11

Building Entrance Terminals

Complementary Products

Single-Pair Protectors

Ordering information follows on the next page

www.te.com/adc

+1-952-938-8080

1-800-366-3891

462

Complementary Products

Building Entrance Terminals: Protection Devices


Single-Pair Protectors
Ordering Information
Catalog Number

25-pair building entrance terminal,


single-pair system

6.25" x 5.75" x 5.06"


(158.7mm x 146mm x 128.6mm)

25' stub

6659 1 025-20/25

50' stub

6659 1 025-20/50

50-pair building entrance terminal,


single-pair system

9.81" x 5.75" x 5.06"


(249.2mm x 146mm x 128.6mm)

25' stub

Complementary Products

Dimensions (HxWxD)

Single-pair system building


entrance terminals
UL 497 listed
26 AWG stub for splicing to incoming 24
AWG cable. Lower switching block field
accepts single-pair protection devices.
Upper disconnect block field provides
direct patching, cross-connection and
look-both-ways testing Quantity: 1

6659 1 050-43/25

50' stub

6659 1 050-43/50

100-pair building entrance


terminal, single-pair system

18.56" x 5.75" x 5.06"


(471.5mm x 146mm x 128.6mm)

25' stub

6659 1 100-73/25

50' stub

6659 1 100-73/50

11/11

Building Entrance Terminals

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

463

Complementary Products

Building Entrance Terminals: Protection Devices

TrueNet Structured Cabling


102094AE

ComProtect K1 series solid-state protector units are UL 497 listed; K2 & K3 series units are
UL 497A listed. The solid-state arrestors respond to voltage transients in 5 nanoseconds (typical).
The single-pair protectors are sold in kits that include 10 units conveniently packaged with a
10-pair ground bar.

ComProtect K1, K2 and K3


protectors have a clip

Type 105 ground bar

Ordering information follows on the next page

11/11

Building Entrance Terminals

Complementary Products

Single-Pair Solid-State Protector Units

www.te.com/adc

+1-952-938-8080

1-800-366-3891

464

Complementary Products

Building Entrance Terminals: Protection Devices


Single-Pair Solid-State Protector Units
Ordering Information
Sneak Current
Protection

Catalog Number
Kit of 10

K1-Series
Used for analog/digital phone systems that
do not require sneak current protection.
Kit includes ground bar
K1-270
K1-75

270V
75V

N/A
N/A

6659 1 000-47
6659 1 000-43

K2-Series
Used for analog/digital phone systems, with
added security of sneak current protection.
Kit includes ground bar
K2-235
K2-75
K2-30

235V
75V
30V

500mA time-delay fuse


500mA time-delay fuse
500mA time-delay fuse

6659 1 000-55
6659 1 000-53
6659 1 000-51

K3-Series
Used for high bit rate digital circuits
(ISDN, DS1, etc.), with added benefit
of sneak current protection.
Kit includes ground bar
K3-235
K3-75
K3-30

235V
75V
30V

500mA time-delay fuse


500mA time-delay fuse
500mA time-delay fuse

6659 1 000-65
6659 1 000-63
6659 1 000-61

Type 105 Ground Bar


Used with ComProtect single-pair
protectors (Series K1, K2, K3). Bar snaps
over cable side of Type 105 block and
provides path to ground for individual
protectors. Mounting bracket must be
properly grounded

Complementary Products

Median
Clamping
Voltage

0.03" x 4.25" x 75"5909 3 041-00


(0.8mm x 107.9mm x 19mm)

Building Entrance Terminals

For complete specifications please contact TE Technical Assistance Center

11/11

102094AE

TrueNet Structured Cabling

Description

www.te.com/adc

+1-952-938-8080

1-800-366-3891

465

11/11

102094AE

TrueNet Structured Cabling

Part Numbers
5ETP-2524WT02 .........................91
5ETR-2524GY02 .........................93
10G-A6TPF-XX02............... 57, 124
10G-A6TP-XX02 ................ 53, 105
10G-A6TRF-XX02 .............. 60, 128
10G-A6TR-XX02 ................ 54, 106
5909 3 041-00 .........................465
6004LFPCBAYYY ............. 396, 398
6004LFPCBCYYY ......................394
6004LFRCBAYYY ............. 402, 404
6004LFRCBCYYY ......................400
6006LFPCBAYYY ............. 396, 398
6006LFPCBCYYY ......................394
6006LFRCBAYYY ............. 402, 404
6006LFRCBCYYY ......................400
6008LFPCBAYYY ............. 396, 398
6008LFPCBCYYY ......................394
6008LFRCBAYYY ............. 402, 404
6008LFRCBCYYY ......................400
6012LFPCBAYYY ............. 396, 398
6012LFPCBCYYY ......................394
6012LFRCBAYYY ............. 402, 404
6012LFRCBCYYY ......................400
6018LFPCBAYYY ............. 396, 398
6018LFPCBCYYY ......................394
6018LFRCBAYYY ............. 402, 404
6018LFRCBCYYY ......................400
6024LFPCBAYYY ............. 396, 398
6024LFPCBCYYY ......................394
6024LFRCBAYYY ............. 402, 404
6024LFRCBCYYY ......................400
6036 1 005-00 .........................406
6036 2 005-02 .........................419
6036 2 018-00 .........................419
6036LFPCBAYYY ............. 396, 398
6036LFPCBCYYY ......................394
6036LFRCBAYYY ............. 402, 404
6036LFRCBCYYY ......................400
6048LFPCBAYYY ............. 396, 398
6048LFPCBCYYY ......................394
6048LFRCBAYYY ............. 402, 404
6048LFRCBCYYY ......................400
6072LFPCBAYYY ............. 396, 398
6072LFPCBCYYY ......................394
6072LFRCBAYYY ............. 402, 404
6072LFRCBCYYY ......................400
6089 2 015-01 ................ 232, 419
6089 2 017-00 .........................416
6089 3 006-00 .........................423
6089 3 006-01 .........................423
6089 3 006-07 .........................423
6089 3 055-02 ................ 423, 441
6089 3 202-00 ................ 416, 423
6096LFPCBAYYY ............. 396, 398

www.te.com/adc

6096LFPCBCYYY ......................394
6096LFRCBAYYY ............. 402, 404
6096LFRCBCYYY ......................400
6144LFPCBAYYY ............. 396, 398
6144LFPCBCYYY ......................394
6144LFRCBAYYY ............. 402, 404
6144LFRCBCYYY ......................400
6196 3 042-00 .........................426
6417 2 055-01 .........................428
6417 3 006-01 .........................428
6417 3 105-00 ................ 423, 441
6417 3 105-01 ................ 423, 441
6417 3 105-07 ................ 423, 441
6418 3 405-00 .........................423
6450 1 101-00 .........................156
6450 1 102-00 .........................156
6450 1 103-00 ................ 109, 156
6450 1 104-00 .........................156
6450 1 107-00 .........................109
6450 1 176-00 .........................157
6450 1 177-00 .........................157
6450 1 178-00 .........................157
6450 2 155-00 .........................157
6450 2 157-00 .........................157
6450 2 158-01 .........................157
6450 2 158-02 .........................157
6450 2 176-00 .........................157
6450 2 177-00 .........................157
6450 2 178-00 .........................157
6451 2 178-04 .........................230
6451 2 700-XX .........................162
6451 2 701-XX .........................162
6451 2 702-XX .........................162
6451 2 703-XX .........................162
6451 2 704-XX .........................162
6451 2 706-XX .........................162
6451 5 035-00 .........................230
6462 2 016-00 ................ 232, 419
6462 2 096-00 ......................., 231
6462 2 097-00 .........................230
6462 2 097-20 .........................230
6462 2 101-01 .........................230
6462 2 408-00 .........................157
6467 5 181-00 ................ 184, 243
6467 5 181-10 ................ 184, 243
6467 5 181-20 ................ 184, 243
6467 5 181-22 ................ 184, 243
6467 5 181-30 ................ 184, 243
6467 5 181-40 ................ 184, 243
6467 5 181-50 ................ 184, 243
6467 5 181-60 ................ 184, 243
6467 5 181-70 ................ 184, 243
6467 5 181-80 ................ 184, 243
6467 5 181-90 ................ 184, 243
6467 5 195-00 ................ 184, 243

+1-952-938-8080

6467 5 195-10 ................ 184, 243


6467 5 195-20 ................ 184, 243
6467 5 195-22 ................ 184, 243
6467 5 195-30 ................ 184, 243
6467 5 195-40 ................ 184, 243
6467 5 195-50 ................ 184, 243
6467 5 195-60 ................ 184, 243
6467 5 195-70 ................ 184, 243
6467 5 195-80 ................ 184, 243
6467 5 195-90 ................ 184, 243
6467 5 198-00 ................ 184, 243
6467 5 198-10 ................ 184, 243
6467 5 198-20 ................ 184, 243
6467 5 198-22 ................ 184, 243
6467 5 198-30 ................ 184, 243
6467 5 198-40 ................ 184, 243
6467 5 198-50 ................ 184, 243
6467 5 198-60 ................ 184, 243
6467 5 198-70 ................ 184, 243
6467 5 198-80 ................ 184, 243
6467 5 198-90 ................ 184, 243
6468 5 060-06 .........................153
6468 5 070-00 .........................111
6468 5 102-00 .........................406
6468 5 300-00 .........................156
6468 5 600-00 .........................156
6585 2 002-0 ...........................429
6586 3 004-00 .........................440
6619 2 046-00 .........................222
6619 2 046-01 .........................222
6619 3 011-00 .........................423
6630 1 009-01 .........................419
6630 2 004-05 ......................., 231
6630 3 025-01 .........................254
6630 3 025-09 ................ 254, 257
6630 3 025-11 .........................255
6631 2 003-00 .........................198
6631 2 050-01 .........................203
6631 2 125-XX .........................258
6631 2 135-00 .........................198
6631 2 135-05 .........................198
6631 2 135-06 .........................198
6631 3 046-08 .........................152
6631 3 085-04 .........................421
6631 3 100-02 .........................421
6631 3 100-03 ................ 234, 421
6631 3 100-04 .........................421
6631 3 100-06 .........................258
6631 3 100-22 .........................198
6631 3 100-23 .........................198
6631 3 100-26 .........................198
6631 3 100-27 .........................198
6631 3 100-28 .........................198
6631 3 100-29 .........................198
6631 3 100-30 .........................198

1-800-366-3891

467

Index

Index

TrueNet Structured Cabling


102094AE

11/11

Index

Index
6631 3 102-01/09 ........... 234, 421
6631 3 102-02/03 ........... 234, 421
6631 3 102-04/06 ........... 234, 421
6631 3 102-05/07 ........... 234, 421
6631 3 102-08 ................ 234, 421
6631 3 105-XX ................ 234, 421
6631 3 106-XX ................ 234, 421
6635 1 140-27 .........................415
6635 1 140-28/50 ....................415
6635 1 140-29 .........................415
6635 1 140-30/50 ....................415
6635 1 140-31 .........................415
6635 1 140-32 .........................415
6635 1 210-08 .........................410
6635 1 220-03 .........................410
6636 1 210-00 .........................408
6636 1 510-06 .........................154
6636 1 518-06 .........................154
6636 1 596-06 .........................154
6636 1 596-46 .........................154
6636 1 598-06 .........................109
6636 1 598-46 .........................109
6637 1 140-30/15 ....................413
6637 1 150-60 .........................196
6637 1 180-03 .........................410
6637 1 180-04 .........................411
6637 1 180-49 .........................412
6637 1 180-51/50 ....................413
6637 1 180-60 .........................196
6637 1 210-04 .........................411
6637 1 210-10 .........................411
6637 1 210-14 .........................412
6637 1 210-60 .........................196
6637 1 250-01/25 ....................413
6637 1 250-01/50 ....................413
6637 1 250-02/50 ....................413
6637 1 320-18/XX ....................458
6637 1 320-19/XX ....................458
6638 1 180-00 .........................408
6638 1 180-21 .........................408
6638 1 180-24 .........................416
6638 1 300-03 .........................408
6638 2 000-00 .........................424
6639 1 003-0 ...........................430
6639 1 003-01 .........................429
6639 1 003-02 .........................430
6639 1 003-03 .........................431
6639 1 003-05 .........................432
6639 1 003-06 .........................433
6639 1 003-07 .........................433
6639 1 003-18 .........................432
6639 1 050-02/01 ....................434
6639 1 050-32 .........................435
6639 1 050-33 .........................435
6639 1 050-44 .........................436

www.te.com/adc

6639 1 051-02/01 ....................434


6639 1 052-01 .........................436
6639 1 056-00/20 ....................437
6639 1 056-01/15 ....................437
6639 1 600-00/25 ....................438
6639 1 600-00/50 ....................438
6639 1 900-00/25 ....................438
6639 1 900-00/50 ....................438
6639 2 004-00 .........................440
6639 3 016-00 .........................440
6639 3 019-00 .........................440
6639 3 019-01 .........................440
6642 1 115-04 .........................200
6642 1 115-05 .........................200
6642 1 315-04 .........................200
6642 1 315-05 .........................200
6644 1 024-01 .........................250
6644 1 024-02 .........................250
6644 1 024-03 .........................250
6644 1 024-04 .........................250
6644 1 024-06 .........................250
6644 1 106-XX .........................250
6644 1 107-XX .........................250
6644 1 112-XX .........................252
6644 1 143-XX .........................252
6644 1 144-XX .........................252
6644 1 152-XX .........................248
6644 1 154-XX .........................248
6644 1 156-XX .........................248
6644 1 157-XX .........................248
6644 1 164-XX .........................248
6644 1 165-01 .........................250
6644 1 165-02 .........................250
6644 1 168-XX .........................248
6644 1 174-XX .........................246
6644 1 178-XX .........................246
6644 1 222-XX .........................253
6644 1 224-XX ................ 253, 257
6644 1 450-XX .........................255
6644 1 460-01 .........................254
6644 2 016-01 .........................257
6644 2 017-XX .........................257
6644 2 018-XX .........................246
6644 2 019-00 .........................250
6644 2 201-XX .........................253
6644 2 202-XX .........................257
6644 3 000-28 .........................250
6644 3 000-53 .........................250
6644 3 205-XX .........................255
6644 3 209-XX .........................255
6644 3 211-XX .........................255
6644 3 220-XX .........................257
6644 3 267-XX .........................255
6644 3 299-XX .........................252
6645 1 157-XX .........................245

+1-952-938-8080

6645 1 158-XX .........................245


6645 1 159-XX .........................245
6645 1 160-01 .........................245
6645 1 160-02 .........................245
6645 1 160-03 .........................245
6645 1 160-04 .........................245
6645 1 166-XX .........................245
6645 1 167-XX .........................245
6645 1 169-XX .........................245
6645 1 172-XX .........................245
6645 1 173-XX .........................245
6645 1 174-XX .........................245
6645 1 180-04 .........................258
6645-2-8X0-YY ........................113
6645-2-8X5-YY ........................113
6645 2 125-XX .........................424
6645 2 126-XX .........................426
6645 2 127-XX .........................230
6645 2 251-XX .........................202
6645 2 254-01 .........................203
6645 2 264-XX .........................202
6645 2 265-XX .........................202
6645 2 266-XX .........................202
6645 2 267-XX .........................202
6645 2 268-XX .........................202
6645-2-770-XX.........................159
6645-2-771-XX.........................159
6645-2-772-XX.........................159
6645-2-773-XX.........................159
6645-2-774-XX.........................159
6645-2-777-XX.........................159
6645-2-780-XX.........................159
6645-2-781-XX.........................159
6645-2-782-XX.........................159
6645-2-783-XX.........................159
6645-2-784-XX.........................159
6645-2-787-XX.........................159
6645-2-790-XX.........................159
6645-2-791-XX.........................159
6645-2-792-XX.........................159
6645-2-793-XX.........................159
6645-2-794-XX.........................159
6645-2-797-XX.........................159
6646 2 900-XX .........................424
6646 2 928-00 .........................424
6646 3 001-01 .........................230
6647 1 010-0 ...........................424
6647 2 000-XX .........................417
6647 2 750-XX .........................417
6647 2 751-XX .........................417
6647 2 752-XX .........................417
6647 2 753-XX .........................417
6647 2 762-XX .........................417
6647 2 782-XX .........................417
6647 2 900-XX .........................424

1-800-366-3891

468

11/11

102094AE

6647 2 906-XX .........................424


6648 2 000-XX .........................161
6648 2 005-XX .........................161
6648 2 900-XX .........................230
6648 2 901-XX .........................230
6649 1 110-01/XX ....................454
6649 1 210-01/XX ....................454
6649 1 310-01/XX ....................454
6649 1 310-02/XX ....................454
6649 1 310-03/XX ....................454
6649 1 310-04/XX ....................454
6649 1 313-01/XX ....................454
6649 1 313-02/XX ....................454
6649 1 316-05/XX ....................454
6649 1 430-09 .........................456
6649 1 470-09 .........................456
6649 1 530-00 .........................456
6649 1 530-09 .........................456
6649 1 570-00 .........................456
6649 1 570-09 .........................456
6649 1 630-00 .........................456
6649 1 630-09 .........................456
6649 1 670-00 .........................456
6649 1 670-09 .........................456
6649 1 720-0 ...........................456
6649 1 760-00 .........................456
6649 1 820-0 ...........................456
6649 1 860-00 .........................456
6649 1 920-00 .........................456
6649 1 960-00 .........................456
6652 1 880-10 .........................429
6652 2 004-00 .........................226
6652 2 004-01 .........................226
6652 2 004-30 .........................225
6652 2 004-54 .........................225
6652 2 004-56 .........................224
6652 2 004-57 .........................225
6652 2 006-00 .........................226
6652 2 006-08 .........................226
6652 2 006-09 .........................226
6652 2 012-42 .........................224
6652 2 012-45 .........................224
6652 2 013-00 .........................224
6652 2 014-00 .........................224
6652 2 015-00 .........................226
6652 2 021-00 .........................224
6652 2 023-02 .........................224
6652 2 039-06 .........................221
6652 2 039-11 .........................221
6652 2 039-21 .........................221
6652 2 040-06 .........................222
6652 2 040-11 .........................222
6652 2 040-21 .........................222
6652 2 067-19 .........................216
6652 2 068-19 .........................216

www.te.com/adc

6652 2 069-19 .........................216


6652 2 069-23 .........................216
6652 2 070-19 .........................216
6652 2 070-23 .........................216
6652 2 080-19 .........................216
6652 2 080-23 .........................216
6652 2 081-19 .........................216
6652 2 081-23 .........................216
6652 2 082-19 .........................216
6652 2 083-19 .........................216
6652 2 100-00 .........................223
6652 2 101-00 .........................223
6652 2 104-00 .........................439
6652 2 104-10 .........................439
6652 2 105-00 .........................439
6652 2 105-18 .........................439
6652 2 108-00 .........................439
6652 2 108-12 .........................439
6652 2 113-00 .........................223
6652 2 114-00 .........................223
6652 2 153-00 .........................210
6652 2 153-14 .........................210
6652 2 330-00 .........................210
6652 2 330-24 .........................210
6652 2 330-34 .........................210
6652 2 452-35 .........................211
6652 2 452-83 .........................211
6653 1 585-24 .................. 47, 180
6653 1 585-48 .................. 47, 180
6653 1 587-24 .................. 47, 180
6653 1 587-48 .................. 47, 180
6653 1 607-00 .........................183
6653 1 608-00 .........................150
6653 1 677-24 .................. 47, 148
6653 1 677-48 .................. 47, 148
6653 1 679-24 .................. 47, 148
6653 1 679-48 .................. 47, 148
6653 2 000-01 .........................148
6653 2 000-02 .........................148
6653 2 700-03 .........................228
6653 2 701-00 .........................228
6653 2 701-01 .........................228
6653 2 701-02 .........................228
6653 2 701-03 .........................228
6653 2 703-00 .........................228
6653 2 703-10 .........................228
6653 2 705-12 ................ 152, 182
6653 2 760-24 ................ 152, 182
6653 3 585-01 .........................228
6654 2 350-06/1 ......................218
6654 2 350-11/1 ......................218
6654 2 350-21/2 ......................218
6655 2 400-00 .........................220
6655 2 400-03 .........................220
6655 2 450-06/1 ......................219

+1-952-938-8080

6655 2 450-11/1 ......................219


6655 2 450-21/2 ......................219
6655 2 450-31/3 ......................219
6655 2 850-0 ...........................427
6655 2 850-10 .........................427
6655 2 850-20 .........................427
6655 2 850-30 .........................427
6655 2 851-05 .........................427
6655 2 851-10 .........................427
6655 2 851-20 .........................427
6655 2 851-30 .........................427
6657 2 005-03 .........................215
6657 2 005-04 .........................215
6657 2 005-19/03 ....................217
6657 2 005-19/04 ....................217
6657 2 005-23/03 ....................217
6657 2 005-23/04 ....................217
6657 2 005-35/04 ....................217
6657 2 005-35/05 ....................217
6657 2 005-35/06 ....................217
6657 2 005-43 .........................215
6657 2 005-44 .........................215
6657 2 006-06/02 ....................217
6657 2 006-09/03 ....................217
6657 2 165-00 .........................213
6657 2 165-40 .........................213
6659 1 000-43 .........................465
6659 1 000-47 .........................465
6659 1 000-51 .........................465
6659 1 000-53 .........................465
6659 1 000-55 .........................465
6659 1 000-61 .........................465
6659 1 000-63 .........................465
6659 1 000-65 .........................465
6659 1 025-20/25 ....................463
6659 1 025-20/50 ....................463
6659 1 025-32/XX ....................458
6659 1 050-43/25 ....................463
6659 1 050-43/50 ....................463
6659 1 100-73/25 ....................463
6659 1 100-73/50 ....................463
6659 1 132-48/XX ....................458
6659 1 132-77 .........................460
6659 1 132-78 .........................460
6659 1 132-79 .........................460
6659 1 132-80 .........................460
6659 1 132-87/XX ....................458
6659 2 053-09 .........................461
6659 2 060-03 .........................461
6730 1 001-00 .........................406
6730 1 001-01 .........................406
6830 1 811-XX .........................130
6830 1 830-XX ................ 158, 242
6830 1 835-XX ................ 112, 241
7014 1 004-03 .........................426

1-800-366-3891

469

Index

TrueNet Structured Cabling

Index

TrueNet Structured Cabling


102094AE

11/11

Index

Index
7014 1 005-00 .........................426
7014 1 012-00 .........................426
7014 1 014-00 .........................426
7014 1 044-00 .........................426
7014 2 006-0 ...........................426
7014 2 007-00 .........................426
7014 3 049-00 .........................426
7022 1 155-24 .........................129
7022 2 155-24 .........................129

A
ADCC06-2 ................................208
ADCCM-06 ...............................208
ADCCM-08 ...............................208
ADCCM-10 ...............................208
ADCCM-12 ...............................208
ADCCMHIB-2U .........................209
ADCCMHIB-3U .........................209
ADCCMHIB-4U .........................209
ADCCMHIBS-3U .......................209
ADCCMHIBS-4U .......................209
ADCCMRSB ..............................209
ADCCMRSB-4 ...........................209
ADCCMS-06 .............................208
ADCCMS-08 .............................208
ADCCMS-10 .............................208
ADCCMS-12 .............................208
ADCCMTG02 .................. 208, 209
ADCCMTG04 .................. 208, 209
ADCCMTG04-23 ......................209
ADCCMVESB06 ........................209
ADCCMVESB08 ........................209
ADCCMVESB10 ........................209
ADCCMVESB12 ........................209
ADCCMVIB-3CB20-4................208
ADCCMVIB-6CB20-4................208
ADCCMVIB06F-2 ......................208
ADCCMVIBC06B4 ....................208
ADCCMVIBC08B4 ....................208
ADCCMVIBC10B4 ....................208
ADCCMVIBC12B4 ....................208
ADCCMVIB-CB-4 ......................208
ADCCMVIB-CB10-4 ..................208
ADCCMVIBS06F-2 ....................208
ADCCMVIBSP ...........................209
ADCDM-TEST ...........................190
ADCLS-CL4A.............................237
ADCLS-CL10A ..........................237
ADCLS-CL12A ..........................237
ADCLS-CL24A ..........................237
ADCLS-CTAPA...........................236
ADCLS-CTAPC ..........................236
ADCLS-DAA ..............................236
ADCLS-FPC ...............................236
ADCLS-FSC ...............................236
ADCLS-FTC ...............................236
ADCLS-HB25C ..........................236
www.te.com/adc

ADCLS-HNGC ...........................236
ADCLS-LSC ...............................236
ADCLS-NGF144LCAR ...............237
ADCLS-NGF144SCAL................237
ADCLS-NGF192LCAL ................237
ADCLS-NGF192LCAR ...............237
ADCLS-PPA ...............................236
ADCLS-SSA ...............................236
ADCLS-TFP1RUA .......................237
ADCLS-TFP2RUA .......................237
ADCLS-TFP5RUA .......................237
ADCPC-T3H1-5100-XX.............194
ADCPC-T3H2-5100-XX.............194
ADCPC-T3H3-5100-XX.............194
ADCPC-T3T3-5100-XX .............194
ADCPP16KSRJRJ .......................192
ADCPP24-DFRJ .........................190
ADCPP24-DRJ ...........................190
ADCPP24RJ5E-S ........................192
ADCPP24RJ6-S..........................192
ADCPP32KSRJRJ .......................192
ADCPP24505 ..................... 47, 192
ADCPP24606 ..................... 47, 192
ADCPP48505 ............................192
ADCPP48606 ............................192
ADCPP245100TEL ............. 47, 193
ADCPP245800BTEL ........... 47, 193
ADCPP485100TEL ....................193
ADCPP485800BTEL ..................193
ADCRACKBLK73 ......................209
ADCRACKBLK73UE-75.............209
ADCRACKBLK73WS .................209
ADCRACKMF73 .......................209
ANP-12NBAS-XXX ....................426

D
D3X24D0-GYYY .........................97
D3X24H0-GYYY .......................101
D4X24D0-GYYY .........................97
D4X24H0-GYYY .......................101
D0024D0-GYYY .........................97
D0024H0-GYYY .......................101
D0224D0-GYR2 ..........................97
D0224D0-GYYY .........................97
D0224H0-GYYY .......................101
D0324D0-GYR2 ..........................97
D0324D0-GYYY .........................97
D0324H0-GYYY .......................101
D0424D0-GYR2 ..........................97
D0424D0-GYYY .........................97
D0424H0-GYYY .......................101
D0624D0-GYR2 ..........................97
D0624D0-GYYY .........................97
D0624H0-GYYY .......................101
D0824D0-GYYY .........................97
D0824H0-GYYY .......................101
D1224D0-GYYY .........................97

+1-952-938-8080

D1224H0-GYYY .......................101
D2524D0-GYYY .........................97
D2524H0-GYYY .......................101
D5024D0-GYYY .........................97
D5024H0-GYYY .......................101
DCC24D0-GYYY ........................97
DCC24H0-GYYY ......................101

E
EB-17B ............................. 209, 316
EB-35B ............................. 209, 316
EB-70B ......................................209
EPLC-PUCK ...............................337
EPLCUSM30095........................336
EPLCXMM30095 ......................336
EP-LOC680................................338
EP-LOC7649 .............................338
EPSCUSM30096BL....................336
EPSCXMM30096BK..................336
EPSTUSM30096YL ....................336
EPSTXMM30096BK ..................336
EPTK-CON .................................338
EPTK-LC ....................................337
EPTK-SC ....................................337
EPTK-ST .....................................337

F
FDF-ACC146 .................... 276, 348
FEC-ACCCLMP01 .....................274
FGS-ACC063 ............................375
FGS-ASRI-5F ..............................372
FGS-ASRI-10F ............................372
FGS-ASRI-15F ............................372
FGSB-ACC063 ..........................375
FGSB-ASRI-5F ............................372
FGSB-ASRI-10F ..........................372
FGSB-ASRI-15F ..........................372
FGSB-ISLAND-H/F ......................378
FGSB-JUNC-G ...........................371
FGSB-KDH2-C ...........................369
FGSB-KT03-A ............................372
FGSB-KT03-A1 ..........................372
FGSB-KT03-C ............................369
FGSB-KTW1-C...........................375
FGSB-KTW1-CA ........................375
FGSB-KTW1-E ...........................375
FGSB-KTW2-D...........................375
FGSB-KTW4-C...........................375
FGSB-KTW4-E ...........................375
FGSB-MCDS-AB ............... 371, 373
FGSB-MCDS-EX-AB.......... 371, 373
FGSB-MD4A-C ..........................369
FGSB-MD4E-A ..........................371
FGSB-MD4E-B ...........................373
FGSB-MD4E-F ...........................374
FGSB-MD4E-G ..........................370
FGSB-MD4E-H ..........................377
FGSB-MD9A-C ..........................369

1-800-366-3891

470

11/11

102094AE

FGSB-MD9E-A ..........................371
FGSB-MD9E-B ...........................373
FGSB-MD9E-F ...........................374
FGSB-MD9E-G ..........................370
FGSB-MDRT-F ............................374
FGSB-MDSA-AB ........................371
FGSB-MDSA-AC........................369
FGSB-MDSA-F2B .......................374
FGSB-MDSA-FB .........................374
FGSB-MDSA-GA .......................370
FGSB-MDSA-GB ........................370
FGSB-MDSP-A...........................371
FGSB-MDSP-B ...........................373
FGSB-MDSP-C...........................369
FGSB-MDSP-EX-A .....................371
FGSB-MDSP-EX-B ......................373
FGSB-MDSP-F............................374
FGSB-MDSP-G...........................370
FGSB-MEX1-C-5F ............. 369, 372
FGSB-MEXC-E-A .......................369
FGSB-MEXC-E-A/B/F .................369
FGSB-MEXC-E-B........................369
FGSB-MEXC-E-F ........................369
FGSB-MEXP-A/B/F .....................369
FGSB-MEXP-E-A/B/F ..................369
FGSB-MEXP-LP-A/B/F ................369
FGSB-MEXP-LP-G ......................370
FGSB-MFAW-A..........................371
FGSB-MFAW-B ..........................373
FGSB-MFAW-F ..........................374
FGSB-MFAW-H..........................376
FGSB-MFTY-5F ..........................375
FGSB-MFTY-10F ........................375
FGSB-MFTY-15F ........................375
FGSB-MFTY-200F ......................375
FGSB-MH4A-C ..........................369
FGSB-MH4E-A ..........................371
FGSB-MH4E-B ...........................373
FGSB-MH4E-F ...........................374
FGSB-MH4E-G ..........................370
FGSB-MH4E-H ..........................377
FGSB-MH9A-C ..........................369
FGSB-MH9E-A ..........................371
FGSB-MH9E-B ...........................373
FGSB-MH9E-F ...........................374
FGSB-MH9E-G ..........................370
FGSB-MHIS-A ............................371
FGSB-MHIS-B ............................373
FGSB-MHIS-F.............................374
FGSB-MHIS-F/H .........................377
FGSB-MHRT-A ...........................371
FGSB-MHRT-B ...........................373
FGSB-MHRT-F ............................374
FGSB-MHRT-F/B .........................374
FGSB-MHRT-G ...........................370

www.te.com/adc

FGSB-MHTA-C ..........................369
FGSB-MHXP-A ..........................371
FGSB-MHXP-B...........................373
FGSB-MHXP-B/F ........................374
FGSB-MHXP-C ..........................369
FGSB-MHXP-F ...........................374
FGSB-MHXP-G ..........................370
FGSB-MHXP-H ..........................377
FGSB-MIDY-5F...........................375
FGSB-MIDY-10F.........................375
FGSB-MIDY-15F.........................375
FGSB-MJWR-A ..........................372
FGSB-MJWR-C ..........................369
FGSB-MJWR-D ..........................375
FGSB-MLDY-100F......................375
FGSB-MLDY-150F......................375
FGSB-MLDY-200F......................375
FGSB-MLDY-250F......................375
FGSB-MSDS-C...........................369
FGSB-MSHA-C ..........................369
FGSB-MSHC-A ..........................371
FGSB-MSHC-B ..........................373
FGSB-MSHC-C ..........................375
FGSB-MSHC-D ..........................375
FGSB-MSHS-A...........................371
FGSB-MSHS-B ...........................373
FGSB-MSHS-C...........................375
FGSB-MSHS-CA ........................375
FGSB-MSHS-D...........................375
FGSB-MSHS-F............................374
FGSB-MSHS-G...........................370
FGSB-MSHS-H...........................376
FGSB-MSNC-B/G .......................370
FGSB-MSNC-F ...........................374
FGSB-MTRM-A..........................372
FGSB-MTRM-B ..........................373
FGSB-MTRM-F...........................374
FGSB-MTRM-G .........................370
FGSB-MU4A-C ..........................369
FGSB-MU4E-A ..........................371
FGSB-MU4E-B ...........................373
FGSB-MU4E-F ...........................374
FGSB-MU4E-G ..........................370
FGSB-MU9A-C ..........................369
FGSB-MU9E-A ..........................371
FGSB-MU9E-B ...........................373
FGSB-MVAR-A ..........................371
FGSB-MVAR-B...........................373
FGSB-MVAR-F ...........................374
FGSB-SD4E-A ............................371
FGSB-SD4E-B ............................373
FGSB-SD9E-A ............................371
FGSB-SD9E-B ............................373
FGSB-SDSA-AB .........................371
FGSB-SH4E-A ............................371

+1-952-938-8080

FGSB-SH4E-B ............................373
FGSB-SH9E-A ............................371
FGSB-SH9E-B ............................373
FGSB-SHRT-A ............................371
FGSB-SHRT-B .............................373
FGSB-SHXP-A ............................371
FGSB-SHXP-B ............................373
FGS-BTBL-C...............................370
FGS-BTBS-C...............................370
FGS-HAEJ-C ..............................370
FGS-HASB-1/2-36 .....................372
FGS-HASB-1/2-48 .....................372
FGS-HASB-5/8-36 .....................372
FGS-HASB-5/8-48 .....................372
FGS-HASK-C .............................370
FGS-HCBL-12 ............................372
FGS-HCBL-15 ............................372
FGS-HDCB-C .............................370
FGS-HDGR ................................372
FGS-HDSI-AB.............................372
FGS-HETP-H-5/8 ........................379
FGS-HETR-1/2 ...........................372
FGS-HETR-5/8 ...........................372
FGS-HETR-5/8-A........................372
FGS-HETR-F-5/8.........................374
FGS-HFCK-1/2 ...........................372
FGS-HFCK-5/8 ...........................372
FGS-HFRR-10 ............................375
FGS-HHEC-10 ...........................375
FGS-HHGK ................................375
FGS-HIFC-A ...............................371
FGS-HIFC-B ...............................373
FGS-HIFC-F ................................374
FGS-HLBK..................................372
FGS-HLDR-5/8 .................. 370, 372
FGS-HLR2-C ..............................370
FGS-HMEC-A ............................371
FGS-HMEC-B.............................373
FGS-HMEC-C ............................369
FGS-HMEC-F .............................374
FGS-HMEC-G ............................370
FGS-HMEC-H ............................377
FGS-HNLR-AB............................372
FGS-HNLR-F...............................374
FGS-HNTP-F-5/8 ........................374
FGS-HNTP-H-5/8 .......................379
FGS-HNTR-1/2 ...........................372
FGS-HNTR-5/8 ...........................372
FGS-HNTR-5/8-A .......................372
FGS-HNTR-F-5/8 ........................374
FGS-HNTS-5/8 ...........................372
FGS-HNTS-5/8-LP ......................372
FGS-HNTS-F-5/8 ........................374
FGS-HNTS-F-5/8-LP ...................374
FGS-HQKK ................................375

1-800-366-3891

471

Index

TrueNet Structured Cabling

Index

TrueNet Structured Cabling


102094AE

11/11

Index

Index
FGS-HSHS-C..............................369
FGS-HTHR-5/8-12 ............ 370, 372
FGS-HTHR-5/8-30 .....................372
FGS-HTHR-5/8-72 .....................372
FGS-HTR2-1/2 ...........................370
FGS-HTR2-5/8 ...........................370
FGS-HTUB-1/2 ...........................372
FGS-HTUB-2-AB ........................370
FGS-HTUB-5/8 ...........................372
FGS-HUFB-C..............................370
FGS-HVHG ................................375
FGS-HWMB-C ...........................375
FGS-HWMB-D ...........................375
FGS-ISLAND-H/F ........................378
FGS-JUNC-G .............................371
FGS-KDH2-C .............................369
FGS-KQKB.................................375
FGS-KT03-A ..............................372
FGS-KT03-A1 ............................372
FGS-KT03-C ..............................369
FGS-KT09 ..................................375
FGS-KTW1-C.............................375
FGS-KTW1-CA ..........................375
FGS-KTW1-E .............................375
FGS-KTW2-D.............................375
FGS-KTW4-C.............................375
FGS-KTW4-E .............................375
FGS-MCDS-AB ................. 371, 373
FGS-MCDS-EX-AB............ 371, 373
FGS-MD4A-C ............................369
FGS-MD4E-A.............................371
FGS-MD4E-B .............................373
FGS-MD4E-F .............................374
FGS-MD4E-G ............................370
FGS-MD4E-H.............................377
FGS-MD9A-C ............................369
FGS-MD9E-A.............................371
FGS-MD9E-B .............................373
FGS-MD9E-F .............................374
FGS-MD9E-G ............................370
FGS-MDRT-F ..............................374
FGS-MDSA-AB ..........................371
FGS-MDSA-AC..........................369
FGS-MDSA-F2B .........................374
FGS-MDSA-FB ...........................374
FGS-MDSA-GA .........................370
FGS-MDSA-GB ..........................370
FGS-MDSA-HF...........................377
FGS-MDSP-A .............................371
FGS-MDSP-B .............................373
FGS-MDSP-C .............................369
FGS-MDSP-EX-A .......................371
FGS-MDSP-EX-B ........................373
FGS-MDSP-F..............................374
FGS-MDSP-G.............................370

www.te.com/adc

FGS-MEX1-C-5F ............... 369, 372


FGS-MEXC-E-A .........................369
FGS-MEXC-E-A/B/F....................369
FGS-MEXC-E-B..........................369
FGS-MEXC-E-F ..........................369
FGS-MEXP-A/B/F .......................369
FGS-MEXP-E-A/B/F ....................369
FGS-MEXP-LP-A/B/F...................369
FGS-MEXP-LP-G ........................370
FGS-MFAW-A............................371
FGS-MFAW-B ............................373
FGS-MFAW-F ............................374
FGS-MFAW-H............................376
FGS-MFTY-5F ............................375
FGS-MFTY-10F ..........................375
FGS-MFTY-15F ..........................375
FGS-MFTY-200F ........................375
FGS-MH4A-C ............................369
FGS-MH4E-A.............................371
FGS-MH4E-B .............................373
FGS-MH4E-F .............................374
FGS-MH4E-G ............................370
FGS-MH4E-H.............................377
FGS-MH4E-H-VS .......................379
FGS-MH9A-C ............................369
FGS-MH9E-A.............................371
FGS-MH9E-B .............................373
FGS-MH9E-F .............................374
FGS-MH9E-G ............................370
FGS-MHIS-A ..............................371
FGS-MHIS-A/H ..........................377
FGS-MHIS-B ..............................373
FGS-MHIS-B/H ...........................377
FGS-MHIS-F...............................374
FGS-MHIS-F/H ...........................377
FGS-MHIS-JIG-A/B/F .371, 373, 374
FGS-MHRT-A .............................371
FGS-MHRT-B .............................373
FGS-MHRT-F ..............................374
FGS-MHRT-F/B ...........................374
FGS-MHRT-G .............................370
FGS-MHRT-H .............................377
FGS-MHRT-H/F ..........................377
FGS-MHRT-H/F-VS .....................379
FGS-MHTA-C ............................369
FGS-MHXP-A ............................371
FGS-MHXP-B .............................373
FGS-MHXP-B/F ..........................374
FGS-MHXP-C ............................369
FGS-MHXP-F .............................374
FGS-MHXP-F/H..........................377
FGS-MHXP-F/H-VS ....................379
FGS-MHXP-G ............................370
FGS-MHXP-H ............................377
FGS-MHXP-H-VS .......................379

+1-952-938-8080

FGS-MIDY-5F.............................375
FGS-MIDY-10F...........................375
FGS-MIDY-15F...........................375
FGS-MJWR-A ............................372
FGS-MJWR-C ............................369
FGS-MJWR-D ............................375
FGS-MKIT-ABF ...........................375
FGS-MLDY-100F........................375
FGS-MLDY-150F........................375
FGS-MLDY-200F........................375
FGS-MLDY-250F........................375
FGS-MSDS-C .............................369
FGS-MSHA-C ............................369
FGS-MSHC-A ............................371
FGS-MSHC-B.............................373
FGS-MSHC-C ............................375
FGS-MSHC-D ............................375
FGS-MSHS-A .............................371
FGS-MSHS-B .............................373
FGS-MSHS-C .............................375
FGS-MSHS-CA ..........................375
FGS-MSHS-D .............................375
FGS-MSHS-F..............................374
FGS-MSHS-G.............................370
FGS-MSHS-H .............................376
FGS-MSNC-B/G .........................370
FGS-MSNC-F .............................374
FGS-MTRM-A............................372
FGS-MTRM-B ............................373
FGS-MTRM-F.............................374
FGS-MTRM-G............................370
FGS-MTRM-H............................378
FGS-MU4A-C ............................369
FGS-MU4E-A.............................371
FGS-MU4E-B .............................373
FGS-MU4E-F .............................374
FGS-MU4E-G ............................370
FGS-MU4E-H.............................377
FGS-MU9A-C ............................369
FGS-MU9E-A.............................371
FGS-MU9E-B .............................373
FGS-MVAR-A ............................371
FGS-MVAR-B .............................373
FGS-MVAR-F .............................374
FGSO-MDSA-HF ........................377
FGSO-MHIS-A/H........................377
FGSO-MHIS-B/H ........................377
FGSO-MHXP-F/H .......................377
FGSO-MU4E-H ..........................377
FGS-SD4E-A ..............................371
FGS-SD4E-B...............................373
FGS-SD9E-A ..............................371
FGS-SD9E-B...............................373
FGS-SDSA-AB............................371
FGS-SH4E-A ..............................371

1-800-366-3891

472

11/11

102094AE

FGS-SH4E-B...............................373
FGS-SH9E-A ..............................371
FGS-SH9E-B...............................373
FGS-SHRT-A...............................371
FGS-SHRT-B ...............................373
FGS-SHXP-A ..............................371
FGS-SHXP-B ..............................373
FL1-A ........................................322
FL1-ACC001 .............................324
FL1-ACC003 .............................324
FL1-ACC004 .............................324
FL1-ACC006 .............................324
FL1-ACC011 .............................324
FL1-B .........................................322
FL1-G ........................................323
FL1-H ........................................323
FL1-J ..........................................323
FL1-M-FT ...................................299
FL1-M-HS ..................................299
FL1-M-MT .................................299
FL1-P .........................................323
FL2-6P4SC605R ............... 307, 325
FL2-6P6JC605R ................ 307, 325
FL2-6P7SC605R ............... 307, 325
FL2-6P8SC605R ............... 307, 325
FL2-6P9JC605R ................ 307, 325
FL2-6PBLNK...................... 293, 306
FL2-6PDJC605R ............... 307, 325
FL2-6PMMDSC ................ 293, 306
FL2-6PMMDSC-A............. 293, 306
FL2-6PMMLC ................... 293, 306
FL2-6PMMLC-A ............... 293, 306
FL2-6PMMSC ................... 306, 324
FL2-6PMMSC-A ............... 293, 306
FL2-6PMMST.................... 293, 306
FL2-6PSMDSC .................. 293, 306
FL2-6PSMLC..................... 293, 306
FL2-6PSMSC .................... 306, 324
FL2-6PSMST ..................... 293, 306
FL2-12RPNL-B ...........................304
FL2-12TS350-B..........................303
FL2-19MAX0175-B ...................311
FL2-19MAX0350-B ...................311
FL2-19MAX0525-B ...................311
FL2-19MAX0700-B ...................311
FL2-19MAX0875-B ...................311
FL2-19MAX1050-B ...................311
FL2-19MAX1400-B ...................311
FL2-19MAX1750-B ...................311
FL2-24RPNL-B ...........................304
FL2-24TS525-B..........................303
FL2-36RPNL-B ...........................304
FL2-48RPNL-B ...........................304
FL2-48SPNL2-B..........................305
FL2-48SPNL-B............................305

www.te.com/adc

FL2-48TS875-B..........................303
FL2-72RPNL-B ...........................304
FL2-72TS140-B..........................303
FL2-96RPNL-B ...........................304
FL2-96SPNL2-B..........................305
FL2-96SPNL-B............................305
FL2-144SPNL2-B .......................305
FL2-144SPNL-B..........................305
FL2-ACC006 .............................304
FL2-ACC007 .................... 304, 305
FL2-ACC008 .............................304
FL2-ACC021 .................... 304, 305
FL2-ACC033 .............................304
FL2-FLMT0175-B .......................310
FL2-FLMT0350-B .......................310
FL2-FLMT0525-B .......................310
FL2-FLMT0700-B .......................310
FL2-FLMT0875-B .......................310
FL2-FLMT1050-B .......................310
FMT-ACC21B ............................300
FMT-ACCCLMP01 ............ 299, 300
FMT-ACCCLMP02 ............ 299, 300
FMT-ACCVCG01B.....................299
FMT-ACCWLMT01 ....................299
FMT-DBS000000-A00B .............294
FMT-DDS000000-A00B.............294
FOTP-1A....................................331
FOTP-2 ......................................331
FOTP-3 ......................................331
FOTP-4 ......................................331
FOTP-5 ......................................331
FOTP-6 ......................................331
FOTP-11 ....................................331
FOTP-21 ....................................331
FOTP-36 ....................................331
FPC-CLNKIT...............................339
FST-DRS12-HS .................. 303, 305
FST-DRS12-MT .........274, 303, 305
FST-DRS24-NT ..........274, 303, 305
FST-DV-HS .................................316
FST-DV-MT ................................316
FST-HS .......................................324
FST-HS-48..................................285
FST-M-FT ...................................300
FST-M-HS.......................... 300, 324
FST-M-MT......................... 300, 324
FST-MT ......................................324

M
MPP-CXFBA1 ............................191
MPP-CXFBA1-S .........................191
MPP-CXZXBT2A ........................191
MPP-CXZXF2.............................191
MPP-CXZXF3.............................191
MPP-CXZXF4.............................191
MPP-DXZBA0 ............................191
MPP-GDXBA1 ...........................191
MPP-GDXBA2 ...........................191
MPP-N28BA1 ............................191
MRE-AM/0KJA003M-18 ...........363
MRE-AM/0KJA004M-18 ...........363
MRE-AM/0KJA005M-18 ...........363
MRE-AM/07JA003M-18 ...........363
MRE-AM/07JA004M-18 ...........363
MRE-AM/07JA005M-18 ...........363
MRM-AF/AFEJxxxF-yy ................360
MRM-AF/AFFAxxxF-yy ...............360
MRM-AF/AFFGxxxF-yy ...............360
MRM-AF/AFFPxxxF-yy................360
MRM-AF/AFGAxxxF-yy ..............360
MRM-AF/AFGGxxxF-yy..............360
MRM-AF/AFGPxxxF-yy...............360
MRM-AF/AFKAxxxF-yy ..............360
MRM-AF/AFKGxxxF-yy ..............360
MRM-AF/AFKPxxxF-yy ...............360
MRM-AF/AFMAxxxF-yy .............360
MRM-AF/AFMPxxxF-yy ..............360
MRM-AF/AFZAxxxF ...................360
MRM-AF/AFZGxxxF ...................360
MRM-AF/AFZPxxxF ....................360
MRM-AM/0PJG003M-18 ..........363
MRM-AM/0PJG004M-18 ..........363
MRM-AM/0PJG005M-18 ..........363
MRM-AM/0PJP003M-18...........363
MRM-AM/0PJP004M-18...........363
MRM-AM/0PJP005M-18...........363
MRM-AM/09JG003M-18..........363
MRM-AM/09JG004M-18..........363
MRM-AM/09JG005M-18..........363
MRM-AM/09JP003M-18 ..........363
MRM-AM/09JP004M-18 ..........363
MRM-AM/09JP005M-18 ..........363
MX6-BAYTEMPLATE .................273
MX6-BSPL-1440-D7 ..................273
MX6-BSPL-1440-U7 ..................273
MX6-SPLIFCCLMP .....................274

IDTK ..........................................337
IPA-K1 .......................................324
IPA-K2 .......................................324

L
LCD-CLIP ...................................336

+1-952-938-8080

1-800-366-3891

473

Index

TrueNet Structured Cabling

Index

Index

TrueNet Structured Cabling


102094AE

11/11

Index

N
NGF-ACCCLMP04 ....................275
NGF-ACCCLMP08 ....................275
NGF-ACCIOSP30X24 ................348
NGF-ACCISOPEG24 ......... 264, 348
NGF-ACCISOPFS12X24.............263
NGFB-ACCEGD007.......... 264, 348
NGFB-ACCFOTSB......................263
NGFB-ACCRCMSLD ..................271
NGFB-ACCRCMSLU ..................271
NGFB-ACCRCMSRD .................271
NGFB-ACCRCMSRU .................271
NGFB-MDF7A100-30................262
NGFB-MDF7A144-30....... 262, 348
NGFB-MPML0C112 ..................348
NGFB-MPML0C612 ..................348
NGFB-MPML0K512...................348
NGFB-MPMR0C112 ..................348
NGFB-MPMR0C612 ..................348
NGFB-MPMR0K512 ..................348
NGFB-TB1MLD7 ........................269
NGFB-TB1MLD9 ........................269
NGFB-TB1MLDT ........................269
NGFB-TB1MLU7 ........................269
NGFB-TB1MLU9 ........................269
NGFB-TB1MLUT ........................269
NGFB-TB1MRD7 .......................269
NGFB-TB1MRD9 .......................269
NGFB-TB1MRDT........................269
NGFB-TB1MRU7 .......................269
NGFB-TB1MRU9 .......................269
NGFB-TB1MRUT........................269
NGFB-TB4MLDC .......................269
NGFB-TB4MLDK............... 269, 270
NGFB-TB4MLDP ........................269
NGFB-TB4MLUC .......................269
NGFB-TB4MLUK............... 269, 270
NGFB-TB4MLUP ........................269
NGFB-TB4MRDC .......................269
NGFB-TB4MRDK .............. 269, 270
NGFB-TB4MRDP........................269
NGFB-TB4MRUC .......................269
NGFB-TB4MRUK .............. 269, 270
NGFB-TB4MRUP........................269
NGFB-TB4QLDC ........................270
NGFB-TB4QLDP.........................270
NGFB-TB4QLUC ........................270
NGFB-TB4QLUP.........................270
NGFB-TB4QRDC........................270
NGFB-TB4QRDP ........................270
NGFB-TB4QRUC........................270
NGFB-TB4QRUP ........................270
NGF-SAP70K00.........................272
NGF-SAP90K00.........................272
NGF-SAPC0J00 .........................272
NGF-SAPC0K00 ........................272
www.te.com/adc

NGF-SAPK0J00 .........................272
NGF-SAPK0K00 ........................272
NGF-SAPP0J00 ..........................272
NGF-SAPP0K00 .........................272
NGF-SAPT0K00 .........................272

P
PP24AC5ET ........................ 47, 181
PP24AC6T.......................... 47, 149
PP24PNPT..................................152
PP48AC5ET ........................ 47, 181
PP48AC6T.......................... 47, 149
PP48PNPT..................................152
PWUEF-7ERN-BLK .....................209

Q
Q006DLTIAPXXX .......................388
Q006DLTIARXXX.......................392
Q008DLTIAPXXX .......................388
Q008DLTIARXXX.......................392
Q012DLTIAPXXX .......................388
Q012DLTIARXXX.......................392
Q024DLTIAPXXX .......................388
Q024DLTIARXXX.......................392
Q036DLTIAPXXX .......................388
Q036DLTIARXXX.......................392
Q048DLTIAPXXX .......................388
Q048DLTIARXXX.......................392
Q072DLTIAPXXX .......................388
Q072DLTIARXXX.......................392
Q096DLTIAPXXX .......................388
Q096DLTIARXXX.......................392
Q144DLTIAPXXX .......................388
Q144DLTIARXXX.......................392
QXXXDLTIOPYYY ......................384
QXXXDLTIORYYY ......................384

R
RINST-TOP7 ...............................276
RMG-00ADP00 .........................316
RMG-06ADPC1................ 317, 329
RMG-06ADPC2................ 317, 329
RMG-06ADPC5.........................329
RMG-06ADPT1 ................ 317, 329
RMG-06ADPT2 ................ 317, 329
RMG-12ADPC3................ 317, 329
RMG-12ADPC4................ 317, 329
RMG-12ADPC6.........................329
RMG-12ADPC7.........................317
RMG-12ADPC8.........................317
RMG-12ADPQ1 ............... 317, 329
RMG-12ADPQ2 ............... 317, 329
RMG-12ADPQ5 ............... 317, 329
RMG-12MPODQ4 .....................354
RMG-12MPOFQ4......................354
RMG-12MPOSC8......................354
RMG-12MPOSQ8 .....................354
RMG-24ADPQ3 ............... 317, 329
RMG-24ADPQ4 ............... 317, 329

+1-952-938-8080

RMG-24ADPQ8 ............... 317, 329


RMG-24MPODQ4 .....................354
RMG-24MPOFQ4......................354
RMG-1000-000B ............. 316, 354
RMG-2000-000B ............. 316, 354
RMG-4000-000B ............. 316, 354
RMG-ACC001 ..........................316
RMG-ACCQBRKT4RU ...............354

T
TFP-00AP00 ..............................285
TFP-1TT00-000B ......285, 351, 352
TFP-2TT00-000B ......285, 351, 352
TFP-4TT00-000B .............. 285, 351
TFP-5TT00-000B .............. 285, 351
TFP-12APLC3 ............................286
TFP-12APLC4 ............................286
TFP-12APLC4DE3 ......................287
TFP-12APLC8 ............................286
TFP-12APLC8SB3 ......................287
TFP-12APRC3 ............................286
TFP-12APRC4 ............................286
TFP-12APRC4DE3 .....................287
TFP-12APRC8 ............................286
TFP-12APRC8SB3 ......................287
TFP-12MPLDQ2.........................351
TFP-12MPLFQ2..........................351
TFP-12MPLSQ5 .........................351
TFP-12MPRDQ2 ........................351
TFP-12MPRFQ2 .........................351
TFP-12MPRSQ5 .........................351
TFP-24APLQ1 ............................286
TFP-24APLQ2 ............................286
TFP-24APLQ2DE3......................287
TFP-24APLQ5 ............................286
TFP-24APLQ5SB3 ......................287
TFP-24APRQ1............................286
TFP-24APRQ2............................286
TFP-24APRQ2DE3 .....................287
TFP-24APRQ5............................286
TFP-24APRQ5SB3......................287
TFP-24MPLDQ2.........................351
TFP-24MPLFQ2..........................351
TFP-24MPLSQ5 .........................351
TFP-24MPRDQ2 ........................351
TFP-24MPRFQ2 .........................351
TFP-24MPRSQ5 .........................351
TFP-72AP0MP ...........................352
TFP-ACC002 .............................352
TFP-VELSTP................................285
TN5ESPX2-XXYY ................ 81, 170
TN5ESP-XXII ....................... 81, 170
TN5ESP-XXRB..................... 81, 170
TN5ESP-XXYY .................... 81, 170
TN5ESRX2-XXYY................ 84, 173
TN5ESR-XXII ....................... 84, 173
TN5ESR-XXRB .................... 84, 173

1-800-366-3891

474

11/11

102094AE

TN5ESR-XXYY .................... 84, 173


TN5ETOSP-BK02 ................ 89, 179
TN6ESD-BL02 ..............................75
TN6ESD-BLRB ..............................75
TN6ESD-CL02 .............................75
TN6ESD-CLRB .............................75
TN6SPX2-XXYY.................. 63, 137
TN6SP-XX02 ...................... 63, 137
TN6SP-XXRB ...................... 63, 137
TN6SR-XX02 ...................... 66, 140
TN6SR-XXRB ...................... 66, 140
TN6TOSP-BK02 .................. 77, 145
TNSCSFPFS03-XX ......................252
TNSCSFPSO4-XX .......................116
TNSCSFPSO4-YY .......................248
TNSCSSB6-XX ...........................117
TNSCSSB6-YY ...........................253
TNSP-36XX02 .................... 69, 143
TNSP-46XX02 .................... 69, 143
TNSP-66XX02 .................... 69, 143
TNSR-3EXX02 .................... 87, 176
TNSR-4EXX02 .................... 87, 176
TNSR-6EXX02 .................... 87, 176
TNSR-36XX02 .............................72
TNSR-46XX02 .............................72
TNSR-66XX02 .............................72
TP5ETA0BLXX ...........................185
TP5ETA0GNXX ..........................185
TP5ETA0GYXX ..........................185
TP5ETA0RDXX...........................185
TP5ETA0WTXX..........................185
TP5ETA0YLXX ...........................185
TP5ETA-BLXX ............................185
TP5ETACBLXX ...........................185
TP5ETACGNXX .........................185
TP5ETACGYXX..........................185
TP5ETACRDXX ..........................185
TP5ETACWTXX .........................185
TP5ETACYLXX ...........................185
TP5ETA-GNXX ...........................185
TP5ETA-GYXX ...........................185
TP5ETAJ0XXYY .........................187
TP5ETAJP0XXYY .......................187
TP5ETAJP-XXYY ........................187
TP5ETAJ-XXYY ..........................187
TP5ETAP0XXYY.........................187
TP5ETAP-XXYY..........................187
TP5ETAR0XXYY ........................187
TP5ETA-RDXX ...........................185
TP5ETAR-XXYY .........................187
TP5ETA-WTXX...........................185
TP5ETA-YLXX ............................185
TP5ETB0BLXX............................201
TP5ETB0GNXX ..........................201
TP5ETB0GYXX ..........................201

www.te.com/adc

TP5ETB0RDXX...........................201
TP5ETB0WTXX ..........................201
TP5ETB0YLXX ...........................201
TP5ETB-BLXX ............................202
TP5ETB-GNXX ...........................202
TP5ETB-RDXX............................202
TP5ETB-WTXX...........................202
TP5ETB-YLXX ............................202
TP5ETF-BLXX .............................201
TP5ETF-GNXX ...........................201
TP5ETF-GYXX............................201
TP5ETF-RDXX ............................201
TP5ETF-WTXX ...........................201
TP5ETF-YLXX.............................201
TP6ATB0XXYY ..........................115
TP6ATB-XXYY ...........................115
TP6ATH0XXYY ..........................115
TP6ATH-XXYY ...........................115
TP6TB0BLXX .............................160
TP6TB0GNXX ............................160
TP6TB0GYXX ............................160
TP6TB0RDXX.............................160
TP6TB0WTXX............................160
TP6TB0YLXX .............................160
TP6TB-BLXX ..............................160
TP6TB-GNXX .............................160
TP6TB-GYXX .............................160
TP6TB-RDXX .............................160
TP6TB-WTXX.............................160
TP6TB-YLXX ..............................160
TP6TH-BLXX ..............................160
TP6TH-GNXX ............................160
TP6TH-GYXX.............................160
TP6TH-RDXX .............................160
TP6TH-WTXX ............................160
TP6TH-YLXX..............................160
TP6TZJ0XXYY............................164
TP6TZJP0XXYY..........................164
TP6TZJP-XXYY...........................164
TP6TZJ-XXYY ............................164
TP6TZP0XXYY ...........................164
TP6TZP-XXYY ............................164
TP6TZR0XXYY...........................164
TP6TZR-XXYY............................164
TP10GTF-BLXX ..........................131
TP10GTF-GYXX.........................131
TP10GTF-WTXX ........................131
TPNP-24APC10-BK ............ 47, 107
TPNP-24APC10-UN ...................107
TPNP-24NC10-BK .............. 47, 108
TPNP-NNC10-NN ......................108
TPNP-NNC10-WM-BKT .............107

+1-952-938-8080

V
VXCCC24-19YY .........................95
VXV0024-18YY ..........................99
VXV0024-19YY ..........................95
VXV0224-18YY ..........................99
VXV0224-19R2 ...........................95
VXV0224-19YY ..........................95
VXV0324-18YY ..........................99
VXV0324-19R2 ...........................95
VXV0324-19YY ..........................95
VXV0424-18YY ..........................99
VXV0424-19R2 ...........................95
VXV0424-19YY ..........................95
VXV0624-18YY ..........................99
VXV0624-19R2 ...........................95
VXV0624-19YY ..........................95
VXV0824-18YY ..........................99
VXV0824-19YY ..........................95
VXV1224-18YY ..........................99
VXV1224-19YY ..........................95
VXV2524-18YY ..........................99
VXV2524-19XX ..........................95
VXV5024-18YY ..........................99
VXV5024-19YY ..........................95
VXV7524-19YY ..........................95
VXVCC24-18YY..........................99

W
WMG-2000-00B .......................327
WMG-4000-00B .......................327
WMG-8000-00B .......................327

1-800-366-3891

475

Index

TrueNet Structured Cabling

Index

ADC is now TE Connectivity

TrueNet structured cabling solutions

TrueNet

Structured Cabling Solutions

4th Edition

4th Edition

Catalog

www.te.com/adc

tE Connectivity, tE connectivity (logo), tyco Electronics, and tE (logo) are trademarks of the tE Connectivity ltd. family of companies
and its licensors.
While tE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, tEConnectivity does
not guarantee that it is error-free, nor does tE Connectivity make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. tE Connectivity reserves the right to make any adjustments to the information contained herein at
any time without notice. tE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including,
but not limited to, any implied warranties of merchantability or fitness for a particular purpose. the dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult
tEConnectivity for the latest dimensions and design specifications.

www.te.com/adc

ADC is now TE Connectivity

contact us:
P.o. Box 1101
Minneapolis, Minnesota
USa 55440-1101
tel: 1-800-366-3891
tel: 1-952-938-8080
Fax: 1-952-917-3237

ADC and Tyco Electronics


are now TE Connectivity

tyco Electronics Corporation, a tE Connectivity ltd. Company. all Rights Reserved.


102094aE11/11Revision 2011, 2008, 2006, 2005

truenet cover.indd 1

8/29/11 3:26 PM

Das könnte Ihnen auch gefallen