Edition 2, 2011
Identification no.
02 03 03 03 001 0 000003
Version no. 0010
Construction
Product
Description
Uses
protective coating on Sika levelling mortar (refer to your product / system data
sheet), fibre cement and overcoating of existing soundly adhering coatings.
Suitable for protection against ingress (Principle 1, method 1.3 of EN 1504-9),
Suitable for moisture control (Principle 2, method 2.3 of EN 1504-9)
Suitable for increasing the resistivity (Principle 8, method 8.3 of EN 1504-9)
Characteristic /
Advantages
Tests
Approvals / Standards
Reaction to fire report MPA Desden, Germany No. 06-6-2069/02 dated 1 August
2006
Product Data
Form
Appearance / Colours
Packaging
15 l pails
Storage
Storage Conditions /
Shelf-Life
1/4
Technical Data
Chemical Base
Density
Solid Volume
Solid Content
Layer Thickness
~ 43%
~ 57%
Minimum required dry thickness to achieve full durability characteristics
(CO2 diffusion, adhesion after thermal cycling, etc.) p180 microns.
Construction
Carbon Dioxyde
Diffusion Coefficient
(CO2)
d = 180 m
SD, CO2 = 66 m
CO2 = 3.7 x 10
SD, CO2 50 m
d = 170 m
Class A1 (+23C)
Cross Cut
GT 0
SD, H2O 5 m
EN 1062-7
EN ISO 2409
0.5
Capillary Absorption
w = 0,03 kg/(mh )
Pull-Off
Adhesion after Thermal
Compatibility
Artificial Weathering
EN 1062-3
EN 1542
EN 13687-part 1 & part 2
EN 1062-11
System
Information
System Structure
Normal absorbent concrete and/or well cured thin layer Sika renders
Product
Number of
applications
Priming
Top Coat*
Priming
Sikagard -551 S Elastic Primer
Top Coat*
Sikagard -675 W ElastoColor
1
2
Priming
Sikagard -552 W Aquaprimer
Top Coat*
Sikagard -675 W ElastoColor
1
2
Priming
Sikagard -705 L (wet on wet) or other Sika
hydrophobic impregnation
Top Coat*
Sikagard -675 W ElastoColor
1- 2
2
Note*:
With intensive yellow or red colour shades and/or a dark substrate, more than two coats might
be required.
2/4
Application Details
Consumption
Product
Per coat
2
~ 0.10 - 0.15 kg/m
2
~ 0.10 - 0.15 kg/m
Sikagard -705 L
~ 0.15 kg/m
2
~ 0.20 - 0.25 kg/m
Construction
If required, a levelling pore sealer (e.g. Sika MonoTop -723N, Sikagard -720
Application
Conditions /
Limitations
Substrate Temperature
Ambient Temperature
Relative Air Humidity
Dew Point
Application
Instructions
Mixing
Application Method /
Tools
Cleaning of Tools
st
The product is supplied ready for use and must be not thinned unless the 1 coat is
used as a primer (refer to coating system structures). In these instances, add up to
15% of water and mix thoroughly. Un-thinned material must be stirred up thoroughly
prior to application.
Waiting Time /
Overcoating
Sikagard -705 L
Waiting time
Next coating
12 hours min.
18 hours min.
5 hours min.
1 hour min.
3/4
Notes on Application /
Limitations
Construction
Curing Details
Curing Treatment
Sikagard -675 W ElastoColor does not require any special curing but must be
protected from rain for at least 2 hours at +20C.
Value Base
All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions
Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
For information and advice on the safe handling, storage and disposal of chemical
products, users should refer to the most recent Material Safety Data Sheet
containing physical, ecological, toxicological and other safety-related data.
Legal Notes
The information, and, in particular, the recommendations relating to the application and end-use of Sika
products, are given in good faith based on Sikas current knowledge and experience of the product when
properly stored, handled and applied under normal conditions in accordances with Sikas recommendations.
In practice, the differences in materials, substrates and actual site conditions are such that no warranty in
respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal
relationship whatsoever, can be inferred either from this information, or from any written recommendations,
or from any other advice offered. The user of the product must test the products suitability for the intended
application and purpose. Sika reserves the right to change the properties of its products. The proprietary
rights of third parties must be observed. All orders are accepted subject to our current terms of sale and
delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request
Branches
Surabaya :
Komp. Pergudangan Meiko Abadi III Blok B-52 & B-53, Ds. Gemurung,
Gedangan, Sidoarjo 61254
Tel : 031-8911333; Fax : 031-8916333
Medan :
Jl. Pancing / Jl. Willem Iskandar No.66 B, Kec. Medan Tembung
Tel : 061- 6619500; Fax : (061) 6619400
Batam :
Jl. Laksamana Bintan, Komp. Bumi Riau Makmur Blok E No.3, Sungai Panas
Tel : (0778) 424928; Fax : (0778) 450189
4/4