Inter-RAT period report interval[ms] = D1000

escription:Interval that the UE reports inter-RAT measurement results to the RNC.


In periodical report mode, the interval between two reports is the configured value. That is, the
UE submits reports at intervals of the configured time. The value "NON_PERIODIC_REPORT"
is, however, not recommended. In this setting, the UE behavior is not defined.
Because the GSM RSSI measurement period is 480 ms, the inter-RAT periodical report interval
should be longer than 480 ms. If InterPeriodReportInterval is excessively high, the handover
judging time will be long, and handovers will be slower.
The InterPeriodReportInterval is adjusted according to the configured GSM RSSI measurement
compressed mode sequence. According to the current configured GSM RSSI measurement
compressed mode sequence, the RSSI measurement of eight GSM cells can be finished in 480
ms, so the RSSI measurement of 16 GSM cells can be finished in 1000 ms. According to the
protocol, not more than 32 inter-RAT neighboring cells exist, so the InterPeriodReportInterval
can be set to 2000 ms if neighboring GSM cells exceeds 16.
This parameter has impact on the Uu signaling flow. If the interval is too short and the frequency
is too high, the RNC may have burden in processing signaling. If the interval is too long, the
network cannot detect the signal change in time, which may delay the inter-RAT handover and
thus cause call drops.
GUI value range:NON_PERIODIC_REPORT(Non periodical reporting), D250~1 D500~2
D1000~3 D2000~4 D3000~5 D4000~6 D6000~7 D8000~8 D12000~9 D16000~10 D20000~11
D24000~12 D28000~13 D32000~14 D64000
Actual value
range:NON_PERIODIC_REPORT,250,500,1000,2000,3000,4000,6000,8000,12000,16000,2000
0,24000,28000,32000,64000
Unit:ms
Default value:D1000
escription:Timer length for inter-RAT measurement.
After inter-RAT measurement starts, if no inter-RAT handover is performed when this timer
times out, the inter-RAT measurement is stopped. In addition, the compressed mode is
deactivated, if any; If the value is 0, you can infer that the inter-RAT measurement timer is not
started.
To set this parameter, you need to consider the following factors:
This parameter aims to prevent that the handover conditions are not met and the compressed
mode is kept for a long time when the UE does not move or is moving in a low speed. The
service quality is adversely affected and the total available capacity decreases if the compressed
mode is kept for a long time.
Most inter-RAT handovers can be finished within 60 s.
As for the impact on network performance,
If the InterRATMeasTime is excessively low, the UE cannot finish inter-RAT handovers. If
InterRATMeasTime is excessively high, it cannot help improve the service quality. In actual
networks, statistics can be made to obtain the delay for a successful inter-RAT handover so as to
get a proper value of InterRATMeasTime that satisfies most UEs.
GUI value range:0~512
Actual value range:0~512
Unit:s

Default value:60
Recommended Value:60

2D event trigger delay time[ms] = D320


2F event trigger delay time[ms] = D1280
3A event trigger delay time[ms] = <NULL>

3A event retry period[500ms] : NULL


GUI value range:1~64
Actual value range:500~32000,Step:500
Unit:ms
Default value:Recommended Value:1