Sie sind auf Seite 1von 6

Aqua-Flo 4

V.S.D. Pump Controller


The most intuitive
user interface in the
Variable Speed Drive
pumping system
market

4 - Pump Controller

4 - Step System Curve

4 - Line Intuitive
Pump Interface

4 - Mode of Operation
Pressure/Flow/Level and
Temperature Control

Engineered by Plad
to be user-friendly!

Aqua-Flo 4

Features and benefits of the Plad Aqua-Flo 4 variable


frequency drive unit:
u

5% impedance input line reactor.

Input choke included to reduce harmonics.

EMC/RFI built-in filter.

Removable 4-line drive keypad display.

High tolerance of voltage and input frequency fluctuations.

Protective drive functions such as: over and under voltage, over
current, loss of phase, over-temperature, motor underload and
stall protection.

PLAD Aqua-Flo 4 Drive


Features:

Password protection.

Hi-performance PID controller.

0-200 psi pressure transducer included for pressure application.

Standard Modbus protocol.

Multi-pump control for a total of 4 pumps with one drive.

R/S 485 communication port.

690 VAC design for 575 VAC motor application.

0-320 Hz frequency.

Optional communication network cards with simultaneous


operation possible on two networks.

Starting current 2 times rated


current for 2 sec every 20 sec.

Variable or constant torque operation.

97% Efficiency or above.

Wide selection of I/O cards for specific application needs.

1200 VDC overvoltage trip


limit on 690 VAC drives.

Plad AF4 features a constant


or variable reference value
such as:
u

Pressure

Flow

u Level
u

Temperature

The Aqua-Flo 4 will vary the speed


of the lead pump motor to maintain a constant pressure, flow,
temperature or level.

2 to 1500 HP/KW.
120 to 690 VAC.
Three-phase asynchronous
motor only.
Single phase input power
available on small HP/KW.
PC software available for
drive set-up.

Incorporating the latest and most


sophisticated semi-conductor
technology, the Plad Aqua-Flo 4
unit provides a flexible, reliable,
and very cost-effective solution
to all variable speed drive multipump application.

Aqua-Flo 4

The Aqua-Flo 4 makes it possible to easily configure and operate


any HVAC variable speed drive pumping system with simplicity and
precision.

Aqua-Flo 4

PLAD AF4 Featuring:


4 - Pump VSD Controller
4 - Step System Curve

V.S.D. Pump Controller

4 - Line Operator Interface


4 - Languages
English, French, Spanish, Italian.

ESC

DEL

EDIT

4 - Operator Modes
Pressure, Flow, Level,
Temperature.

ENTER

4 - Types of Starters
Drive, AXL, soft-starters and
intelligent motor controller.

The Aqua-Flo 4 is a variable frequency drive and a programmable logic


controller in one compact unit with an easy-to-use operator interface.

4 - Communication Protocols
Modbus, Profibus, DP and
Device Net.

The Aqua-Flo 4 is even more than just a user-interface, it is a frequency


drive communicator, a wizard, in few words, a very intuitive operator
interface.

4 - Input Voltages
120/230/460/600 VAC.

This latest VFD/Pump controller technology is available from


Plad Equipment Ltd., the leader in VSD water booster.

4 - Certifications
UL - CSA - CE - FI

Aqua-Flo 4 - Step System Curve


450

TDH (ft)

4 - pumps in parallel

400

350

P1+P2

P1

P1+P2+P3

All 4 Pumps

130 psi

Constant Pressure Line

300

120 psi

Energy Savings
110 psi

250

100 psi

+10

System curve
proportional
to the square
of the flow

+10

+10

P2 On

P1 only

P3 On

P4 On

200

150

Flow (gpm)
0

Fig. A

200

400

600

800

1000

1200

Constant pressure booster vs Aqua-Flo 4 - step system curve VSD water booster

1400

1800

Aqua-Flo 4

Plad Aqua-Flo 4 Benefits


This built-in variable frequency inverter and microprocessor controls
the logic of operation of a multi-pump system in order to regulate
pressure, flow, level, or temperature.
The Aqua-Flo 4 is the brain of the control system, monitoring the
speed of the lead pump and controlling starting and stopping of
three lag pumps.

PID Loop Multi-pump controller


The included PID sophisticated regulator controls the speed of the
variable speed drive lead pump and provides start and stop signals
to a total of three auxiliary lag pumps.

4-line operator interface


The display of the AF4 is a 4-line operator interface designed with an
intuitive scroll-down menu interface and is available in 4 languages.
Password protection is available for security and to protect important
operating data.

Lead pump monitoring


The Aqua-Flo 4 displays the most important parameters of the lead
pump; speed, amperage, voltage, temperature and many others as
well as providing a quick access to drive parameters such as minimum
and maximum speed limits and acceleration/decelaration factors.

Total Flow display


The Aqua-Flo 4 monitoring interface provides automatic regulation
for pressure, level, or temperature, and always accept a second
analog 4-20mA signal to monitor the pumping system total flow
capacity.
This feature is built-into the unit, and is available when a flow signal
transducer is connected to the second analog input of the drive.

Additional benefits

Provides pumping system alternation mode.


Start of the next available pump if one fails.
Low pressure shut-down.
External 4-20 mA signal available.
Reference value can be upgraded every time an
additional pump is started, providing the best
system curve.
Pressure loss compensation device.

Aqua-Flo 4

Easy to use
Welcome to the simplicity of scroll
down type menu. The Aqua-Flo 4
operator interface is simple, intuitive and perfect for the monitoring and control of your pump
application.

Powerful communication
possibilities
The Aqua-Flo 4 Multi-pump
standard application includes the
use of one variable frequency
drive and a maximum of 3 AXL
magnetic starters for lag pumps.
Multi-drive pump application is
possible with a maximum of 4
drives or any combination of one
variable frequency drive and three
intelligent motor protectors, or
electronic soft starters.

Example of 4-line
plain english screen
for the Aqua-Flo 4
operator interface.

Plad Aqua-Flo 4 operator interface offers functional enhancements


for monitoring, control and diagnostic display of a multi-pump variable
speed drive pumping system.

PLAD Aqua-Flo 4
Multi-pump communication
with different possible drivers

Aqua-Flo 4

Variable frequency drives


Electronic soft starters
Intelligent motor controllers
Magnetic contactors

ESC

DEL

V.S.D. Pump Controller

EDIT

ENTER

Alternate motor controls


for lag pumps instead of
AXL magnetic contactors.
The Aqua-Flo 4
communicates and reads
current on all these motor
control equipment.

Modbus Communication Protocols R/S 485

Start/Stop
Start/Stop
Start/Stop

Lead Pump
Variable
Frequency Drive

Electronic Starters
for lag pumps
with soft stop

Intelligent motor
controller with thermal
overload protection

Lag pump
multi-drive
application

Aqua-Flo 4

PLAD Water Booster Systems

Variflo VSD Pumping Systems

Custom-built to meet your exact requirements,


Plad Water Booster Systems represent a quality

Built with vertical in-line PLAD centrifugal single


stage or multi-stage, end-suction or split-case
pumps.

assurance for a long term investment.

Premium efficiency or inverter duty type electric


motors.

All mechanical and electrical components included

Pressure relief valve assembly.

in fixed speed or variable speed drive water boosters are specifically selected to provide a complete

Victaulic type construction.


Silent wafer type check valves.

package of perfectly matched drives, pumps, con-

New and improve software for P.L.C. and


operator interface.

troller and sensors.

C.S.A. - U.L.

Quality Assurance for Factory Assembled


Pre-Tested Hydraulic Recovery Turbines
Each PLAD water booster is hydraulically tested before
shipment to ensure optimum system
performance and reliability.
Engineered Product for Ultimate Pumping Value
Plad Equipment Ltd. represents quality and service with
over 40 years of experience in the design, manufacture
and application of centrifugal pumps and pre-fabricated
pumping systems.

Web Site: www.plad.com


E-mail:
2005 Plad Equipment Ltd. 2005/03/28

sales@plad.com