AMIPOX GRE Fiberglass Systems

LO

ES
O
LU
TI
O

PD

Series AT - ASL - AP

Performance

Uses and Applications

Hydrostatic Design Basis


Brackish water

Brine

Crude oil transmission

Electrical conduits

Fire fighting systems

Oilfield injection

Potable water

Saltwater and seawater

Sewage, draining systems

The pipe wall design uses a 122 MPa (17.600 psi)


HDB with a 0.5-service factor for static design
(ASTM D-2992 Procedure B). The laminate meets
the requirements of API 15LR Specification, ANSI/
AWWA-C950 and ISO Standard. Classification as per
ASTM D-2310 / ASTM D-2996: RTRP-11FW (Static).

Design Pressure

General Industrial Services for corrosive liquides

Other applications on request

* for higher pressure, consult Amipox Engineering

ES
O
LU
TI
O

series up to 100 bar (1450 psi)


series up to 70 bar (1015 psi)
series up to 20* bar (290 psi)

PD

AT
ASL
AP

The series are designed for the following pressure


ratings:

The systems are designed to provide a minimal 3:1


safety factor in accordance with ASTM D-1599.

Maximum Operating Temperature

The maximum operating temperature is 120C (250F).


Between 90C and 120C values must be degraded
linearly. For detailed specifications please contact us.

Pipe Description

LO

Amipox GRE pipe Series AT, ASL and AP are produced


by a filament winding process. These pipes are RTR
(Reinforced Thermosetting Resin). The pipe structural
wall consists of continuous glass fibers (E-glass) wound
at a 54 2 helical angle in a matrix of amine-cured
epoxy resin. The resin-rich liner 0.5 mm (20 mills)
consists of C-glass (C-veil) and the same resin system
as used in the pipe wall. Conductive pipes can be
produced on request.

Fittings
Amipox fittings are either filament-wound or mitered
made of segments. They are made from the same glass
and resin materials as the pipe.

Pipe Properties

Dimensions
Our Amipox GRE Pipes Series AT, ASL and AP
are produced from DN 80 (3) up to DN 1200 (48).
The standard random length supplied is 9 m (30 ft) for
DN 80 up to DN 600 and 12 m (40 ft) for DN 200 up to
DN 1200.

Thermal Conductivity
(ASTM C-177)

0.33 W/(mK)

105 Pa = 14.5 Psi = 1.02 kg/cm2


1 N/mm2 = 145 Psi = 10.2 kg/cm2
25.4 mm
0.113 Nm

Thermal linear Expansion 18.0x10-6 mm/mm C


(ASTM D-696)
Flow Coefficient
150
(Hazen-Williams)

5.3x10-6 m

0.1442 W (mK)

Absolute Roughness
Density

LO

Value Unit
at 93C

200

N/mm2

ASTM D-2290
ASTM D-2290

220
25200
0.56

-
22100
0.70

N/mm2
N/mm2

ASTM D-2105
ASTM D-2105
ASTM D-2105

80.0
12500
0.37
85

65
9700
0.41
-

N/mm2
N/mm2

ASTM D-2925

12500

8000

N/mm2

Circumferential
Hoop tensile stress
Hooptensile modulus
Poissons ratio: axial/hoop

Beam
Apparent elastic modulus

Value
at 21C

ES
O
LU
TI
O


Method


Bi-Axial
ASTM D-1599
Hoop stress at weeping

Mechanical properties

Longitudinal
Axial tensile strength
Tensile modulus
Poissons ratio: hoop/axial
Axial bending strength

1.8 g/cm3

PD

1 bar
=
1 MPa
=
1 inch
=
1 lb.in
=
1 Btu (int.)
in/hr.sqft.F =

Conversions





Physical properties

Hydrostatic Design Basis


Static HDB
ASTM D-2992
-

procedure B

N/mm2

122* (20 years) N/mm2


114* (50 years)

* at 65C (150F)

Wall Thickness
Nominal
size

ID
14
2.5
2.5
2.5
2.5
3.4
4.0
4.6
5.2
5.7
6.3
7.5
8.7
9.2
9.8
11.0
12.1
12.7
13.3
14.5

16
2.5
2.5
2.5
3.2
3.8
4.5
5.2
5.8
6.5
7.2
8.5
9.8
10.5
11.2
12.5
13.8
14.5
15.2
16.5

40
3.2
3.9
5.6
7.3
9.0
10.7
12.4
14.1
15.8
17.5
20.9

50
3.9
4.8
6.9
9.1
11.2
13.4
15.5
17.7
19.8

60
4.7
5.7
8.3
10.9
13.5
16.1
18.7

70
5.4
6.6
9.7
12.7
15.8
18.8
21.9

50
1.8
2.7
6.0
10.5
16.3
23.4
31.7
41.3
52.2

60
2.2
3.3
7.3
12.8
19.8
28.4
38.6

70
2.5
3.9
8.6
15.1
23.5
33.7
45.7

50
6.8
10.6
23.7
42.0
65.4
94.1
127.9
167.0
211.2

60
7.2
11.2
24.9
44.2
68.9
99.1
134.8

70
7.6
11.7
26.3
46.5
72.6
104.3
141.9

PD

mm
in
mm
10
12
80
3
80
2.5
2.5
100
4
100
2.5
2.5
150
6
150
2.5
2.5
200
8
200
2.5
2.5
250
10
250
2.5
3.0
300
12
300
3.0
3.5
350
14
350
3.4
4.0
400
16
400
3.8
4.5
450
18
450
4.2
5.0
500
20
500
4.6
5.5
600
24
600
5.5
6.5
700
28
700
6.3
7.5
750
30
750
6.7
8.0
800
32
800
7.1
8.5
900
36
900
8.0
9.5
1000
40
1000
8.8
10.5
1050
42
1050
9.2
11.0
1100
44
1100
9.6
11.5
1200
48
1200
10.5
12.5
Indicated wall thickness includes 0.5 mm liner.

Minimum wall thickness in mm


Pressure class (bar)
20
25
32
2.5
2.5
2.7
2.5
2.6
3.2
3.0
3.6
4.6
3.8
4.7
5.9
4.7
5.7
7.3
5.5
6.8
8.6
6.4
7.8
10.0
7.2
8.9
11.3
8.0
9.9
12.7
8.9
11.0
14.0
10.5
13.1
16.7
12.2
15.2
19.4
13.0
16.2
20.8
13.9
17.3
22.1
15.6
19.4
24.8
17.2
21.5
27.5
18.1
22.5
18.9
23.6
20.6
25.7

mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

10
1.3
1.7
2.5
3.3
4.1
4.9
6.5
8.3
10.4
12.8
18.2
24.5
28.0
31.8
40.0
49.2
54.2
59.3
70.4

12
1.3
1.7
2.5
3.3
4.1
5.7
7.7
9.9
12.4
15.2
21.7
29.3
33.5
38.0
47.9
58.9
64.8
71.0
84.3

14
1.3
1.7
2.5
3.3
4.7
6.6
8.8
11.4
14.4
17.6
25.2
34.0
38.9
44.2
55.7
68.6
75.5
82.8
98.3

in
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48

mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

ID

LO

Nominal
size

ES
O
LU
TI
O

Empty Pipe Weight

Approximate weight of pipe excluding joints


Pressure class (bar)
16
20
25
32
1.3
1.3
1.3
1.3
1.7
1.7
1.7
1.8
2.5
2.5
3.0
3.8
3.4
4.2
5.2
6.7
5.3
6.5
8.1
10.3
7.5
9.2
11.5
14.7
10.0
12.5
15.5
19.9
13.0
16.2
20.2
25.9
16.4
20.4
25.4
32.7
20.1
25.0
31.3
40.3
28.7
35.8
44.8
57.7
38.8
48.5
60.8
78.3
44.4
55.6
69.7
89.8
50.5
63.1
79.2
102.1
63.7
79.7
100.0
129.0
78.4
98.1
123.2
159.0
86.3
108.1
135.7
94.6
118.5
148.8
112.4
140.8
176.9

in kg/m
40
1.4
2.2
4.8
8.4
13.0
18.5
25.1
32.7
41.2
50.8
72.8

Filled Pipe Weight


Nominal
size
mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

in
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48

ID
mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

10
6.4
9.5
20.1
34.7
53.1
75.5
102.7
134.0
169.5
209.1
300.9
409.4
469.8
534.5
676.2
834.6
920.1
1,009.7
1,201.4

12
6.4
9.5
20.1
34.7
53.1
76.4
103.9
135.5
171.4
211.6
304.4
414.1
475.3
540.6
684.0
844.3
930.7
1,021.3
1,215.3

14
6.4
9.5
20.1
34.7
53.7
77.3
105.1
137.1
173.4
214.0
307.9
418.9
480.7
546.9
691.9
854.0
941.4
1,033.1
1,229.3

Filled pipe weight (kg/m), fluid density (1000 kg/m3)


Pressure class (bar)
16
20
25
32
40
6.4
6.4
6.4
6.4
6.5
9.5
9.5
9.5
9.6
10.1
20.1
20.1
20.7
21.5
22.5
34.9
35.7
36.7
38.1
39.8
54.4
55.6
57.2
59.4
62.0
78.2
79.9
82.2
85.4
89.2
106.3
108.7
111.8
116.2
121.3
138.7
141.8
145.9
151.6
158.3
175.4
179.4
184.5
191.7
200.3
216.4
221.4
227.7
236.6
247.1
311.4
318.5
327.6
340.5
355.6
423.7
433.3
445.6
463.2
486.2
497.4
511.5
531.6
553.1
565.8
581.8
604.7
699.8
715.8
736.1
765.1
863.8
883.5
908.6
944.4
952.2
974.0
1,001.6
1,044.9
1,068.8
1,099.2
1,243.3
1,271.8
1,307.9

Surge Pressure

Field Testing

The maximum allowable surge pressure is 1.5 times the


rated pressure.

The pipe system is designed for field testing with water


at 1.5 times the rated design pressure.

External Pressure Performance

10
32.8
32.8
32.8
32.8
32.8
56.7
82.5
115.2
155.6
204.4
349.4
525.1
631.6
751.6
1,075.2
1,431.1
1,635.2
1,857.9
2,431.0

12
32.8
32.8
32.8
32.8
56.7
89.3
133.2
189.7
260.2
346.2
571.4
877.7
1,065.2
1,277.6
1,783.5
2,408.0
2,768.6
3,163.5
4,062.4

14
32.8
32.8
32.8
32.8
83.4
133.8
201.3
288.3
397.4
531.0
881.8
1,360.6
1,654.2
1,987.3
2,781.8
3,764.0
4,331.8
4,953.9
6,371.3

SF per ASTM D-2412 in Nm at 21C


Pressure class (bar)
16
20
25
32
40
32.8
32.8
32.8
41.3
70.2
32.8
32.8
36.9
69.0
124.7
32.8
57.2
102.0
198.3
369.2
66.7
119.3
217.8
432.5
817.8
118.3
215.3
398.7
802.5
1,532.6
191.4
352.6
659.5
1,339.5
2,575.5
289.6
538.4
1,014.6
2,074.6
4,008.5
416.8
780.2
1,478.6
3,038.8
5,893.6
576.7
1,085.3
2,066.1
4,263.3
8,292.7
773.0
1,461.2
2,791.6
5,779.1 11,267.8
1,289.7
2,454.3
4,715.0
9,809.2 19,194.1
1,996.7
3,818.6
7,365.4 15,377.8
2,431.0
4,658.4
8,999.6 18,816.8
2,924.1
5,613.0 10,859.3 22,733.7
4,101.6
7,896.3 15,313.2 32,125.6
5,559.0 10,727.6 20,843.7 43,802.3
6,402.1 12,367.1 24,049.1
7,326.4 14,165.6 27,567.3
9,433.5 18,269.4 35,600.5

14
31.37
16.36
4.97
2.12
2.75
2.56
2.42
2.33
2.25
2.20
2.11
2.05
2.03
2.01
1.98
1.95
1.94
1.93
1.91

PS per ASTM D-2412 in bar 21C


Pressure class (bar)
20
25
32
31.37
31.37
39.24
16.36
18.35
33.70
8.57
15.10
28.85
7.56
13.63
26.60
7.00
12.80
25.31
6.64
12.26
24.47
6.39
11.89
23.88
6.20
11.61
23.45
6.06
11.40
23.11
5.95
11.23
22.85
5.79
10.99
22.45
5.68
10.81
22.17
5.63
10.74
22.06
5.59
10.68
21.97
5.52
10.58
21.81
5.47
10.50
21.68
5.45
10.47
5.43
10.43
5.39
10.38

mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

in
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48

LO

mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

ID

ES
O
LU
TI
O

Stiffness Factor (SF)


Nominal
size

50
50.13
50.13
50.13
50.13
50.13
50.13
50.13
50.13
50.13

60
88.89
88.89
88.89
88.89
88.89
88.89
88.89

70
144.88
144.88
144.88
144.88
144.88
144.88
144.88

50
127.5
230.5
699.6
1,570.2
2,966.5
5,012.8
7,833.1
11,551.8
16,293.0

60
211.5
386.9
1,194.5
2,705.1
5,139.0
8,716.5
13,657.8

70
328.2
606.0
1,894.4
4,318.3
8,236.8
14,008.7
21,993.0

50
115.80
107.57
97.19
92.24
89.36
87.46
86.13
85.13
84.37

60
187.15
175.96
161.72
154.87
150.86
148.22
146.35

70
283.07
268.54
249.90
240.89
235.58
232.08
229.61

mm
10
80
19.40
100
9.93
150
2.94
200
1.24
250
0.64
300
0.37
350
0.36
400
0.36
450
0.36
500
0.36
600
0.36
700
0.36
750
0.36
800
0.36
900
0.36
1000
0.36
1050
0.36
1100
0.36
1200
0.36
21C. Use 70%

Allowable collapse pressure (bar) at 21C


Pressure class (bar)
12
14
16
20
25
32
40
19.40
19.40
19.40
19.40
19.40
19.40
25.02
9.93
9.93
9.93
9.93
9.93
12.55
25.02
2.94
2.94
2.94
2.97
5.88
12.55
25.02
1.24
1.24
1.51
2.97
5.88
12.55
25.02
0.64
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
25.02
0.63
1.00
1.51
2.97
5.88
12.55
0.63
1.00
1.51
2.97
5.88
12.55
0.63
1.00
1.51
2.97
5.88
12.55
0.63
1.00
1.51
2.97
5.88
12.55
0.63
1.00
1.51
2.97
5.88
12.55
0.63
1.00
1.51
2.97
5.88
0.63
1.00
1.51
2.97
5.88
0.63
1.00
1.51
2.97
5.88
of the above values for industrial applications and 30% for marine applications.

PD

mm
in
80
3
100
4
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
1050
42
1100
44
1200
48
Pressure ratings at

ID

Nominal
size

Pipe Stiffness (PS)


Nominal
size
mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

in
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48

ID
mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

10
31.37
16.36
4.97
2.12
1.09
1.09
1.00
0.94
0.89
0.85
0.85
0.80
0.78
0.77
0.77
0.75
0.74
0.73
0.74

12
31.37
16.36
4.97
2.12
1.88
1.71
1.61
1.54
1.48
1.44
1.38
1.33
1.31
1.30
1.27
1.25
1.24
1.24
1.22

16
31.37
16.36
4.97
4.27
3.88
3.64
3.47
3.35
3.25
3.18
3.07
3.00
2.97
2.94
2.90
2.86
2.85
2.84
2.81

40
65.38
59.69
52.62
49.29
47.36
46.10
45.22
44.56
44.05
43.65
43.05

Specific Tangential Stiffness (STIS)


Nominal
size
mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

in
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48

STIS in N/m2 21C


Pressure class (bar)
20
25
32
58,436
58,436
73,079
30,470
34,174
62,762
15,961
28,120
53,725
14,088
25,390
49,541
13,036
23,838
47,135
12,364
22,838
45,574
11,898
22,141
44,480
11,557
21,628
43,671
11,295
21,234
43,048
11,089
20,922
42,554
10,785
20,460
41,819
10,570
20,134
41,300
10,485
20,004
41,093
10,412
19,892
40,913
10,289
19,704
40,614
10,192
19,556
40,375
10,150
19,492
10,113
19,434
10,047
19,334

ID
mm
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1050
1100
1200

10
58,436
30,470
9,252
3,952
2,038
2,038
1,870
1,750
1,660
1,591
1,574
1,490
1,458
1,430
1,436
1,394
1,376
1,360
1,371

12
58,436
30,470
9,252
3,952
3,501
3,194
3,004
2,866
2,762
2,681
2,562
2,479
2,446
2,418
2,371
2,334
2,318
2,304
2,279

14
58,436
30,470
9,252
3,952
5,125
4,763
4,515
4,335
4,198
4,091
3,933
3,823
3,780
3,742
3,680
3,630
3,609
3,590
3,557

16
58,436
30,470
9,252
7,952
7,233
6,778
6,465
6,236
6,062
5,925
5,724
5,583
5,527
5,478
5,398
5,335
5,307
5,283
5,240

50
215,682
200,350
181,011
171,805
166,427
162,902
160,414
158,564
157,134

60
348,572
327,734
301,195
288,450
280,969
276,051
272,571

PD

Minimum allowable bending radius in meter 21C and standard pressure rating
Pressure class (bar)
mm
in
mm
10
12
14
16
20
25
32
40
50
60
80
3
80
14.45
15.18
15.99
16.89
19.04
22.63
30.82
41.27
41.62
41.98
100
4
100
19.07
20.36
21.85
23.56
27.95
36.48
51.17
51.52
51.96
52.41
150
6
150
33.58
37.81
43.26
50.55
75.87
76.19
76.64
77.16
77.82
78.49
200
8
200
54.61
66.76
85.87
100.74
101.08
101.50
102.10
102.79
103.67
104.57
250
10
250
87.83
124.43
125.66
125.87
126.29
126.82
127.57
128.43
129.53
130.65
300
12
300 148.41
150.49
150.74
150.99
151.50
152.13
153.03
154.07
155.39
156.73
350
14
350 175.24
175.53
175.82
176.12
176.70
177.44
178.49
179.70
181.24
182.81
400
16
400 200.23
200.57
200.91
201.24
201.91
202.76
203.96
205.34
207.10
450
18
450 225.22
225.61
225.99
226.36
227.12
228.07
229.42
230.98
232.96
500
20
500 250.21
250.65
251.07
251.49
252.33
253.39
254.88
256.61
600
24
600 300.25
300.73
301.23
301.74
302.74
304.01
305.81
307.89
700
28
700 350.23
350.81
351.40
351.98
353.16
354.64
356.74
750
30
750 375.22
375.86
376.48
377.11
378.37
379.96
382.20
800
32
800 400.21
400.90
401.56
402.23
403.58
405.27
407.66
900
36
900 450.25
450.98
451.73
452.48
453.99
455.90
458.59
1000
40
1000 500.23
501.06
501.89
502.73
504.41
506.52
509.52
1050
42
1050 525.22
526.10
526.97
527.85
529.62
531.84
1100
44
1100 550.21
551.14
552.06
552.98
554.82
557.15
1200
48
1200 600.25
601.22
602.22
603.22
605.24
607.78
Note: Do not bend the pipe until the adhesive is cured. Sharper bends may create excessive stress concentration.
Nominal
size

70
527,212
500,147
465,430
448,652
438,769
432,257
427,642

Bending Radius

40
121,766
111,174
97,997
91,803
88,211
85,867
84,218
82,994
82,050
81,300
80,183

70
42.34
52.86
79.17
105.48
131.79
158.09
184.40

LO

ES
O
LU
TI
O

ID

Span lengths

Partial span recommendations in meters 21C for horizontal support arrangement


Pressure class (bar)
mm
in
mm
10
12
14
16
20
25
32
40
50
60
70
80
3
80
4.22
4.22
4.22
4.22
4.22
4.22
4.22
4.29
4.47
4.64
4.78
100
4
100
4.49
4.49
4.49
4.49
4.49
4.49
4.55
4.75
4.97
5.16
5.32
150
6
150
5.00
5.00
5.00
5.00
5.01
5.23
5.50
5.76
6.04
6.27
6.48
200
8
200
5.40
5.40
5.40
5.47
5.72
5.99
6.31
6.62
6.94
7.22
7.46
250
10
250
5.72
5.72
5.90
6.06
6.36
6.66
7.03
7.38
7.74
8.05
8.32
300
12
300
6.00
6.22
6.42
6.61
6.93
7.28
7.68
8.06
8.47
8.81
9.11
350
14
350
6.44
6.69
6.91
7.11
7.46
7.84
8.28
8.69
9.13
9.50
9.83
400
16
400
6.85
7.12
7.36
7.58
7.96
8.36
8.83
9.28
9.75
450
18
450
7.24
7.53
7.79
8.02
8.43
8.86
9.36
9.84
10.34
500
20
500
7.61
7.92
8.19
8.44
8.87
9.32
9.86
10.36
600
24
600
8.30
8.64
8.94
9.22
9.69
10.20
10.78
11.34
700
28
700
8.93
9.31
9.64
9.93
10.45
11.00
11.63
750
30
750
9.23
9.62
9.96
10.27
10.81
11.38
12.04
800
32
800
9.52
9.93
10.28
10.60
11.16
11.75
12.43
900
36
900
10.08
10.51
10.89
11.23
11.83
12.45
13.17
1000
40
1000
10.61
11.07
11.47
11.83
12.46
13.11
13.88
1050
42
1050
10.87
11.33
11.75
12.12
12.76
13.43
1100
44
1100
11.12
11.59
12.02
12.40
13.05
13.75
1200
48
1200
11.60
12.10
12.54
12.94
13.63
14.35
Note: For continuous span, use the given values plus 20%. For simple span, use the given values minus 20%. The span recommendations are
based on pipes filled with water with a specific gravity of 1000 kg/m3, and include no provision for additional weights caused by valves, flanges,
or other heavy objects. The span recommendations are calculated for a maximum long-time deflection of 13 mm. (1/2-inch) to ensure good
appearance and adequate drainage.
Nominal
size

ID

Fittings

Joining Systems

Filament-wound Fittings

We offer various different


joining systems

Filament-wound fittings are made on steel moulds.


Sizes available are from 80-600 mm (3-24). The wall
construction consists of a reinforcement structure
(which is made of a combination of E-glass materials
impregnated with amine-cured epoxy resin) and an
inner liner (C-veil glass impregnated with the same resin
system as the reinforcement structure).

AT Adhesive Taper-Taper Joint


AT series, adhesive bonded taper-taper joint, max.
pressure rating 100 bar.

PD

Available range:
90 and 45 Elbows
Tees and Laterals
Tapered-Body Reducers
Reducer Bushings and Plugs
Plugs and Pipe Caps
Nipples
Saddles
Coupling
Flanges and Reducing Flanges

The AT series with taper-taper joints


The ASL series with traditional mechanical seal lock,
with O ring and with locking key
The AP series with plain ends laminated joints

ES
O
LU
TI
O

ASL Seal-Lock Joint Key and O Ring Sealing


ASL series Seal-lock-joint is a connection with an
O ring and a locking key; max. pressure rates 70 bar.

Laminated segmented Fittings

Flanges

LO

Available range:
90 and 45 Elbows
Equal and Reducing Tees
Equal and Reducing Laterals
Other non standard fittings

Laminated segmented fittings are available in sizes


from DN 80 mm up to DN 1,200 mm (3-48).
They are made out of GRE pipe segments which are
cut, fitted and laminated to the required shape.

The range includes DN 80-1200 mm (3-48) flanged


fittings which are in accordance with ANSI B16.1 and
B16.5 drilling class.
Other flange drilling patterns such as DIN, ISO and
JIS are available on request.
Flanges could be Standard, Heavy Duty or Van Stone
type with O ring or flat gasket.

Butt-And-Wrap (or Lamination) joint


This joint for plain ends is used generally for field
adjustments and for large diameter pipes and in case
other types of joints are not available.
Butt & Wrap Joints are available for all sizes.

Distributed by:

AMIPOX
First Industrial City
P.O. Box 589
Dammam, 31421
Saudi Arabia
Tel.: + 966 (3) 847 1500
Fax: + 966 92 000 4070
info@amiantit.com
www.amiantit.com

AP-F2 V4 01-13-ENG

LO

ES
O
LU
TI
O

PD

Utmost care has been taken to


ensure that all contents of this
brochure are accurate. However,
AMIANTIT and its subsidiaries do
not accept responsibility for any
problems which may arise as a
result of errors in this publication.
Therefore customers should make
inquiries into the potential product
supplier and convince themselves
of the suitability of any products
supplied or manufactured by
AMIANTIT and/or its subsidiaries
before using them.

Das könnte Ihnen auch gefallen