7. TECHNICAL CHARACTERISTICS
TYPE
INPUT (W)
VOLTAGE (V)
CLASS
OF ROTECTION
IP
DIMENSIONS (mm)
ECOSUN S09
900
230 V 1N
IP X4
1500 150 60
ECOSUN S12
1200
230 V 1N
IP X4
1500 150 60
ECOSUN S18
1800
230/400 V 2N
IP X4
1500 250 60
ECOSUN S24
2400
230/400 V 2N
IP X4
1500 250 60
ECOSUN S30
3000
230/400 V 3N
IP X4
1500 350 60
ECOSUN S36
3600
230/400 V 3N
IP X4
1500 350 60
8. NOTICE
Do not touch by dirty hand on the radiant surface of the panel.
9. GUARANTEE CONDITIONS
Producer gives 24 months guarantee on his products. Guarantee does not cover defects caused by transport,
negligent manipulation or unprofessional installation.
Name: ____________________________________________________
Address: __________________________________________________
________________________________________________________
Date of sale: _______________________________________________
Type of product: _____________________________________________
The symbol means that the electric appliance must be collected and disposed separately as electrical and electronic waste and must not be disposed as unsorted
communal waste as required by the Directive 2002/96/EC of the European Parliament of 27 January 2003 on waste electrical and electronic equipment. The
symbol also means that the product was launched after 13 August 2005.
As required by the Directive 2002/95/EC of the European Parliament of 27 January 2003 on the restricted use of some hazardous substances in electrical
and electronic equipment, the product does not contain any hazardous substances or contains them in admissible quantities.
Dispose of the product in the point of sale or any place of collection of sorted waste.
Thank you.
INSTALLATION INSTRUCTIONS
1. GENERAL INFORMATIONS
4. ELECTRIC CONNECTION
2. USING
These panels are determined for heating of bigger spaces. There are recommended mainly for industry halls, workshops,
etc. storage areas, shops, sports and common halls. They can be used for zone heating of requested areas too.
S0912
3. ASSEMBLY
Panels are suspended on four fixation points by chain or can be fix to auxiliary frame. Auxiliary frame is fixed
to ceiling with screws.
Picture No.1 Panels fixation
Position of panel is necessary to fix by set screws against accidental pull out.
S1824
auxiliary frame
fixation point
S3036
panel
Minimum distances of fixation points on the back side of panels
TYPE
DIMENSIONS (mm)
ECOSUN S09
80 1000
ECOSUN S12
80 1000
ECOSUN S18
195 1000
ECOSUN S24
195 1000
ECOSUN S30
195 1000
ECOSUN S36
195 1000
NOTICE
template for drill frame holes as a part of delivery
diameter of holes 6 m
auxiliary frame is a standard part of delivery
do not touch by dirty hand on the radiant surface during installation
and handling of the panel
1,0 m
10 cm
1,5 m
3,5 m
recomended distance
Distances between panels are normally greater than height of the panel form the floor.
5. CONTROL
Control system should be of such a type as to ensure that the instaled panels are operated correctly. It is
recommend that the Fenix thermostat incorporating a timer should be used. These thermostats ensure
connection by relay or contactor. For large areas and instalations, it is possible to utilise microprocessor control
system.
ECOSUN S30 S36 panels may be operated by switching of the individual sectinons as follows; it is possible
to regulate by switching of the of single sections. First step middle sections, second step both outer sections,
third step all sections on.
6. MAINTENANCE
There is possible only cleaning of carriage body of panel by gentle brush and detergent. Do not clean radiant
surface of the panel, cleaning can cause its damage.