Sie sind auf Seite 1von 2

Product data sheet

Characteristics

XMLF100D2025

pressure sensor 100 bar - G1/4 (female) - 24 V


- NO or NC - 4..20 mA

Main
200 mA

Electrical connection

4 pins male connector M12

Fluid connection type

G 1/4 (female) conforming to ISO 228

Controlled fluid

Air (-15 - 80 C)
Corrosive fluid (-15 - 80 C)
Fresh water (-15 - 80 C)
Hydraulic oil (-15 - 80 C)
Sea water (-15 - 80 C)

Type of output signal

Analogue + discrete

Discrete output type

Solid state PNP or NPN programmable, 1 NO or 1


NC programmable

Analogue output function

4...20 mA

Materials in contact wth


fluid

FPM (Viton)
Stainless steel type AISI 303

Type of installation

Control circuit

Pressure swt type of


operation

Regulation between 2 thresholds

Pressure sensor size

100 bar

Adj range low setting

5...97 bar

Adj range high setting

8...100 bar

Possible diff min at low


setg

3 bar

Possible diff min at high


setg

3 bar

Possible diff max at


high setg

95 bar

Max perm accidental


pressure

400 bar

Destruction pressure

600 bar

Range of product

OsiSense XM

Pressure sensor name

XMLF

Product or component
type

Electronic pressure sensors

Product specific application

Type of scale

Adjustable differential scale

Local display

With

Us rated supply voltage

24 V DC, voltage limits: 17 - 33 V

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Maximum switching
current

Complementary
CAD overall depth

58 mm

CAD overall height

113 mm

CAD overall width

46 mm

Current consumption

80 mA

Drift of the sensitivity

< +/- 0.03 % of msrg range /C

Drift of the zero point

< +/- 0.1 % of msrg range /C

Mechanical durability

>= 10000000 cycles

Protection type

Connection faults
Overload protection
Reverse polarity
Short-circuit protection

Feb 2, 2015

Time delay range

0 - 50 s in steps of 1 second

Setting

External setting

Operating rate in Hz

<= 50 Hz

Response time on output

5 - 500 ms, in steps of 1 ms

Display response time type

Fast
Normal
Slow

Surge withstand

0.5 kV DC

Product weight

0.5 kg

Measurement accuracy

<= 0.6 % of the measuring range

Repeat accuracy

<= 0.5 %

Environment
Protective treatment

TC

Vibration resistance

35 gn (f = 60 - 2000 Hz) conforming to IEC 68-2-6


5 gn (f = 25 - 200 Hz) conforming to IEC 68-2-6

Shock resistance

50 gn conforming to IEC 68-2-27

Resistance to fast transients

2 kV conforming to EN 61000-4-4

IP degree of protection

IP67 conforming to EN/IEC 60529

NEMA degree of protection

NEMA 12
NEMA 13
NEMA 4
NEMA 6

Operating position

Any position

Standards

CE
EN 50081
EN 50082
EN 61000-4-11
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-6-2
EN/IEC 60947-1
EN/IEC 60947-5-1

Product certifications

CSA
UL

Ambient air temp for op

-25...80 C

Resist electrostatic dischrg

4 kV (on contact) conforming to EN 61000-4-2


8 kV (in air) conforming to EN 61000-4-2

Resist to electromagn fields

10 V/m conforming to EN 61000-4-3

Resist to conductd disturbs

10 V conforming to EN 61000-4-6