Combine safety and performance

Masterpact and Compact Micrologic trip units provide outstanding


protection as well as an integrated measurement unit to help you monitor
power conditions and manage energy consumption.

Micrologic Trip Unit

Micrologic offer for Masterpact & Compact NS


Micrologic

Micrologic 5.0 A

Micrologic 2.0

5.0 E

Micrologic 6.0 E

2100A

Type of measurement
Version

100 %

40 %

40 %

Type of current protection


.7
.6
.5
.4

.8

x In

tr
8
(s) 4
.9
12
16
.95 2
.98 1
20
24
1
.5

alarm

Ir

instantaneous

Isd

2.5
2
1.5

4 5

x Ir

long time

.7
.6
.5
.4

at 6 Ir

.8

x In

tr
(s) 4 8 12
.9
16
.95
2
.98 1
20
24
1
.5

short time

Isd 4
5
3
2.5
6
2
8
1.5
10
x Ir

8
10

setting

alarm

tsd
(s)

.4 .4 .3

.3
.2
.1

on

setting

I t

Ii

.2
.1

delay

long time

Ir

.7
.6
.5
.4

at 6 Ir

instantaneous

8 10
12
4
15
3
2
off
x In
6

Isd

tr
8
(s) 4
.9
12
16
.95 2
.98 1
20
24
1
.5

.8

x In

2.5
2
1.5

4 5

x Ir

alarm

6
8
10

tsd

.4 .4 .3
.2
.3
.1
.2
.1 2 0

(s)

on

setting

D E F
G
C
H
B
I
A

.7
.6
.5
.4

I t

Ii

instantaneous

delay

on

I t

(A)

3
2
1
.5

off

2: Distribution L, I

2.0

2.0

2.0

>> Optimize power consumption

5: Selective L, S, I

5.0

5.0

>> Cost allocation

6: Selective and earth-fault protection L, S, I, G

6.0

6.0

Power metering and control

7: Selective protection with earth-leakage protection L, S, I, V

tr
8
(s) 4
.9
12
16
.95 2
.98 1
20
24
1
.5

.8

x In

Selection guide

alarm

@ 6 Ir

tsd

.4 .4 .3
.2
.3
.1
.2
.1 2 0

(s)

on

I t

off

Ii

instantaneous

4
3

6 8 10
12
15
off
2
x In

delay

t
(ms)
230
7
10
140
20
30
60

test

350
800

earth leakage

Industry

setting

In

.4 .4 .3
.2
.3
.1
.2
.1 2 0

(s)

through communication.

50

short time

test

tg

without

>> Integration in a Building Management System

50

Isd
4
5
3
2.5
6
2
8
1.5
10
x Ir

8 10
12
4
15
3
off
2
x In
6

ground fault

Power management and monitoring

100

long time

Ir

at 6 Ir

short time

Ig

Building & Infrastructure

N 1 2 3

N 1 2 3
100

menu

menu

long time

Ir

for Masterpact and Compact

4200A

4260A

_ _5.678

100 %

Micrologic 5.0 H

Micrologic 7.0 P

MWh

5.0

5.0

5.0

6.0

6.0

6.0

7.0

7.0

7.0

Micrologic offer for Compact NSX

>> Advanced protection


>> Alarming and programmable contact

Micrologic

5.3 E

>> Cost allocation

Type of measurement
Basic Frame Size

>> Diagnostic and maintenance

Type of current protection

>> Continuity of service

5: Selective L, S, I

5.2 5.3

5.2 5.3

6: Selective and earth-fault protection L, S, I, G

6.2 6.3

6.2* 6.3*

>> Load trend monitoring


>> Integration in a supervision and control system
through communication (SCADA, DCS, etc.)
>> Management of energy quality.

IT
Critical Power

1: Motors I

without

1.3

2: Distribution L, I

2.2** 2.3*

* Motor protection available ** Generator and motor protection available

>> Suitable for specific and advanced protection


>> Diagnostic and maintenance
>> Load trend monitoring
>> Integration in a supervision and control system
through communication

A=
E=
P=
H=
M=
Without =

Current measurement
Energy measurement
Power measurement
Harmonic measurement
Motor protection
No measurement

L=
S=
I=
G=
V=

Long time protection


Short time protection
Instantaneous protection
Ground fault protection
Earth Leakage protection

>> Management of energy quality.

Marine
High current protection

Make the most of your energy


www.schneider-electric.com

>> Specific motor protection


>> Total discrimination
>> Diagnostic and maintenance
>> Optimized size solution
>> Integration in a supervision and control system
through communication (SCADA, DCS, etc.)
>> Continuity of service.

Schneider Electric Industries SAS


35, rue Joseph Monier
CS 30323
F- 92506 Rueil Malmaison Cedex
RCS Nanterre 954 503 439
Capital social 896 313 776 e
www.schneider-electric.com

EDCED112019EN

As standards, specifications and designs change from time to time, please ask for confirmation
of the information given in this publication.
Printed on ecological paper
Publishing: Schneider Electric Industries SAS
Design - Layout: SEDOC
Printing: Altavia Connexion
07-2012

ART.056274 2012 Schneider Electric Industries - All rights reserved.

>> Power availability

Das könnte Ihnen auch gefallen