Data Sheet 60.8550

Page 1/2

Contact dial thermometers


for transformers
Class 1.5
Series 8550
in stainless steel case
Protection IP54
Case size 80mm and 100mm dia.
Brief description
Contact dial thermometers for transformers are universal instruments for local
temperature measurement.
Features

anti-corrosion stainless steel case


Protection IP54
one or two contacts (microswitch: UL and CSA approved)
contact rating 3 / 5 or 10 A

Type designation

Ordering example

8550

Contact dial thermometer


Type:
8550-10-80
Range:
-20 to +120C
Extra Code:
TZ 086
Contact:
SA 20
Temperature probe: TF 05, brass,
8mm dia.
Probe mounting:
TA 22, 1" pipe male A,
brass, S =150 mm

Series
Contact dial thermometer
for transformers

Style
8550-10-..

Case sizes
8550-10-80 case 80 mm dia.
8550-10-10 case 100 mm dia.

Ranges
(similar to DIN 16 203)
Scale*

Measuring
range
C

Accuracy

0 +120

+20 +100

20 +120

0 +100

* other scale ranges to special order

(details for standard version)


Case
case, bezel and protective cover:
stainless steel, Mat. Ref. 1.4301
Base
aluminium die-casting GD-AlSi12,
Mat. Ref. 3.2582.05

Temperature probe (TF)


TF 05, brass, 8 mm dia. throughout

Scale
white, black lettering;
other versions to special order

Probe mountings (TA)


TA 21 3/8" pipe male A, brass,
probe with union nut and conical seal

Window
PMMA (Plexiglass)

TA 22

1/ "
2
3/ "
4

pipe male A, brass


pipe male A, brass

Indication
linear, pointer movement approx. 260

TA 22 1" pipe male A, brass


probe with union nut, conical seal and
loose nipple

Measuring system
liquid-filled

Extra Codes (TZ)

Indication accuracy
3C over measuring range

TZ 012 microswitch 10(3) A 250 V AC,


TZ 060 scale to customer specification
TZ 086 peak-reading pointer, screwdriver
adjustment; protected by screw
cap
05.01/00074772

Technical data

Contact output (SA)


SA 20: one contact
SA 21: two contacts
see page 2 for connection diagram

TA 22
C

Type 8550-10-80

Dynamic response
t90% response 25 sec approx.
(measured in agitated water with 8 mm dia.
brass probe)

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany

Ambient temperature error in % of scale


range
based on deviation from +23C reference
value
0.15% of scale per C ambient temperature variation
Contact type
single-pole microswitch with mechanically
operated changeover contact
Switching point accuracy
0.5% of scale referred to switch-off point
on rising temperature
Switching differential
approx.1.5% of scale
(on 250 V AC 3 / 5 A)
TZ 012
1.5 to 3% of scale
(on 250 V AC 10 A )

Data Sheet 60.8550

Page 2/2

Contact rating
250 V AC 3(1) A (max. 50 000 operations)
250 V AC 5(1.5) A (max. 10 000 operations)

Permitted ambient temperature


-30 to +70C

TZ 012
250 V AC 10(3) A
(approx. 25 000 operations)

Contact output (SA)


Connection diagrams
SA 20

values in brackets for inductive load,


p.f.= 0.6

to ensure maximum switching reliability, we


recommend a minimum voltage of 24 V AC
and a minimum current of 20 mA
Electrical connection
screw terminals, for conductor crosssection up to 2.5 mm2, protected by
cover with Pg16 cable gland.
Suitable for cable diameters from 6.5 to
16 mm.

>
2

SA 21
S1

Setpoint adjustment
with screwdriver, protected by screw cap.

S2
11

>

>

12 14

21

22 24

Nominal position
NL90, symbol

Dimensions

Probe mounting TA 21
Type
8550-10-80
8550-10-10

Probe mounting TA 22

D
dia.

D1
dia.

80

85

100

106

L9
with TA 20
77
87

Note:
for dial thermometers with bimetallic measuring systems,
transformer version, see Data Sheet 60.8005.
for dial thermometers and contact dial thermometers with
capillaries, see Data Sheets 60.8201 and 60.8520.
05.01/00074772

STA21 STA22

G
thread size

a/f

L1

158*

150*

pipe A
pipe A

17
27

14

150*
150*

3/ "
8
1/ "
2
3/ "
4

pipe A
1" pipe A

32
27

16
18

with TA 22
85
95

L
active probe length

* other stem lengths to special order

range
range
0 +120C 20 +120C
60 mm
70 mm
approx.
approx.

Das könnte Ihnen auch gefallen