You can undo all pipe and junction movements using Undo on the Edit menu or Tool

bar.
When moving pipes or junctions, you can press the Escape key to cancel the movem
ent.
If you double click the checkbox on the Checklist window or Status Bar, the appr
opriate window will be opened. For example, double-clicking Specify Output Contr
ol will open the Output Control window.
To move a selected group of objects, use a junction icon, instead of a pipe, to
drag the group. This will avoid missing the pipe and clicking on an empty area o
f the Workspace, which will deselect your group.
If you want certain sections of the model to be numbered in sequence, then use t
he Renumber feature on the selected sections only. It is also preferable in the
case of large or complicated models to renumber small sections at a time.
To choose only English or SI units for all parameters, go to the Unit Preference
s folder tab, choose the Default Unit System then click the Apply Default Units
button. This will use AFT Fathom s default units. This will also change the prefer
red units.
The Scenario Manager allows you to keep all of your design cases together in a s
ingle file where scenario children inherit changes.
You can model hydraulic losses from components and fittings using either junctio
n icons or Additional Minor Losses embedded in pipes.
AFT Fathom uses the most sophisticated models available to calculate losses at t
ees and wyes. The methods, which come from Idelchik, take into account losses th
at depend on the flow split, area change and angle of the branch pipe.
You can model a pump with a variable speed controller to control pump discharge
pressure or flow. This is done in using the pump data as a polynomial in the Pum
p Specifications window and setting the desired flow or discharge pressure on th
e "Auxiliary Input" folder tab. AFT Fathom will calculate the pump speed require
d to produce the flow or pressure conditions specified and display the speed in
the Pump Summary report.
AFT Fathom offers several non-Newtonian fluid models including Power Law and Bin
gham Plastic.
AFT Fathom can model fire sprinkler systems using Spray Discharge junctions.
AFT Fathom allows you to model the heat transfer in a piping system, and perform
s and energy balance on the entire pipe system coupled together with the flow so
lution.
You can close valves, pumps and other pipe system components using the Special C
ondition tool found on the junction specifications window and on the Edit menu o
r Toolbar.
You can use manufacturer pressure drop data by modeling the component using a Ge
neral Polynomial loss.
You can show the pipe or junction names on the Workspace by selecting the checkb
ox on the pipe or junction specifications window Optional tab.
You can use the Global Pipe Edit and Global Junction Edit to make changes to mul
tiple pipes or junctions all at once.
You can set your preferred engineering units in the Parameter and Unit Preferenc
es window accessed from the Options menu.
You can create a liquid mixture in the System Properties window using the Chempa
k database.
You can merge two models together using the Merge tool on the File menu.
You can run multiple models unattended using the Batch Run tool on the File menu
.
There are three ways to enable or disable the Highlight feature in the pipe and
junction specifications window. The first is toggling the option on the Options
menu. The second is pressing the F2 function key while in a Pipe and Junction Sp
ecifications window. The third is double-clicking the anywhere in the Pipe and J
unction Specifications window.
You can quickly find a particular pipe or junction on the Workspace by using the
Find feature on the View menu.
You can change the reference positive flow direction for one or more pipes by se

lecting the pipe or pipes and choosing the Reverse Direction feature on the Arra
nge menu.
You can quickly find all undefined pipes and junctions in the model using the Fi
nd tool on the View menu. The Find window allows you to display all pipes and ju
nctions, or only those that are undefined.
In the Model Data tabular displays, click the far-left column where the pipe or
junction number is located and the appropriate Specifications window will be ope
ned.
When in the Output window viewing results you can quickly change the units for p
arameters in the tabular displays by double-clicking the column header.
If you hold down the CTRL key when completing the pipe drawing (just before rele
asing the mouse button), the Pipe Drawing tool remains active, and you can draw
a series of pipes without returning to the Toolbox each time. If you double-clic
k the Pipe Drawing tool it remains active until you click it again a single time
. This allows you to draw a series of pipes without returning to the Toolbox eac
h time.
You can add graphical segments to a pipe so it is not constrained to a single st
raight line using the Segment Pipe tool found on the Arrange Menu.
The toolbars and menu in AFT Fathom can be customized by right-clicking on the t
oolbar area or selecting the Customize Toolbars and Menu from the Options menu.
Here you can modify any of the toolbars or the main AFT Fathom menu. You also ca
n create your own toolbars, which are saved for future use.
You can change the icon for a junction in AFT Fathom by opening the Junction Spe
cifications window, clicking the Optional folder tab, and then clicking the Chan
ge Icon button.
When using the Selection Drawing Tool on the Workspace Toolbox, if you hold down
the CTRL key when completing the selection drawing (just before releasing the m
ouse button), the Selection Drawing Tool remains active. The CTRL key thus perfo
rms the same function as double-clicking the tool.
When using the Selection Drawing Tool on the Workspace Toolbox, if you first dou
ble-click the Selection Drawing Tool or hold down the CTRL key, you can also hol
d down the SHIFT key while drawing the selection box and the enclosed pipes and
junctions will be deselected.
When using the Selection Drawing Tool on the Workspace Toolbox, if you first dou
ble-click the Selection Drawing Tool or hold down the CTRL key, you can also hol
d down the ALT key while drawing the selection box and the enclosed pipes and ju
nction selections will toggle. That is, any pipes or junctions that were selecte
d will become deselected, and vice versa.
When using the Zoom Select tool on the Workspace Toolbox, if you hold down the S
HIFT key down while selecting the zoom area, the zoom state will always be 100%.
If you hold down CTRL key and select a junction from the Toolbox and drop it ont
o an existing Workspace junction, the old junction will "morph" into the new one
. The junction type will change to the new junction type, and data that can be k
ept will be copied into the new junction.
If you hold down the SHIFT key when you perform an inspection on the Workspace,
only the items not yet defined are displayed.
If you hold down the CTRL key when you perform an inspection, the inspection win
dow will show the output data for the pipe or junction.
When in a pipe specifications window, if you press the F5 function key, you will
jump to the next highest numbered pipe. If you press the CTRL key while pressin
g the F5 function key, you will jump to the next lowest numbered pipe. The F5 fu
nction key also behaves this way for junction specifications windows.
Select Special is a tool for selecting or deselecting objects based on certain c
riteria. Depending on the location from where it is opened, pipes, junctions or
both may be selected. This tool allows you to quickly select a group of objects.
Groups of pipes and junctions can be named for later recall. This is done using
the Group Tools on the Edit menu. You can include Subgroups inside of your Group
s. After you have created a Group, you can then quickly reselect that Group of p
ipes or Junctions on the Workspace by choosing Group -> Select from the Edit men
u or Toolbar and choosing the name of the Group.

Bookmarks can be added on the Workspace in relation to individual pipes or junct


ions. You can quickly navigate around the Workspace by moving from Bookmark to B
ookmark. Use the Bookmark tools on the View menu to set Bookmarks and to display
different bookmarked pipes or junctions.
After a converged answer is obtained, you can choose to take these results and u
se them as the initial guesses for a subsequent run. This causes much faster con
vergence in subsequent runs because you are starting the solver at or very close
to the actual solution. This feature is called Transfer Results to Initial Gues
s, and it is on the Output window Edit menu and toolbar.
The Flow Total utility feature is convenient for getting a quick answer on how m
uch inflow or outflow has been specified for a group of Assigned Flow or Branch
junctions. This option is enabled only after a model is completely defined.
By clicking the Jump button in a Specifications window, you can move directly to
another Specifications window by choosing a pipe or junction.
By pressing the F5 function key while in a pipe or junction specifications windo
w, you will jump to the next highest numbered pipe or junction. By pressing the
CTRL key along with F5, you will jump to the next lowest pipe or junction.
A design alert allows you to specify certain maximum and/or minimum parameters f
or the pipe. After running the Solver, if the pipe solution shows that one of th
ese design alerts is exceeded, a warning is given in the output. Design Alerts a
re specified in the Pipe Specifications window.
You can specify that pipe or junction labels can only be moved on the Workspace
when the Shift key is pressed. Sometimes the labels get in the way of selecting
the pipes or junctions themselves and are moved accidentally. You can change thi
s to use the Shift key in the Allowable Workspace label movements area in Worksp
ace Preferences.
A grid can be displayed on the Workspace background for modeling convenience. Th
e grid can be fine, medium or coarse. The grid lines can be solid or dashed. And
finally, the pipes and junctions can be snapped to the grid you specify. The gr
id is specified on the Workspace Preferences window opened from the Options menu
.
You can make the Workspace graphical pipe line thicknesses appear proportional t
o the actual pipe diameter. Thus larger diameter pipes will appear thicker. The
pipe line thickness option is specified on the Workspace Preferences window open
ed from the Options menu.
When new pipes or junctions are added to the Workspace, they are assigned a new
number that is greater than the highest pipe or junctions number by one. The inc
rement can be changed from this default to a higher value. The auto increment op
tion is specified on the Workspace Preferences window opened from the Options me
nu.
You can turn on the Autosave in the General Preferences window opened from the O
ptions menu.
You can specify that backup copies be kept of your models in the General Prefere
nces window opened from the Options menu.
You can specify a default model location in the General Preferences window opene
d from the Options menu.
You can specify design factors for pipes or junctions, which multiply the pipe o
r junction pressure loss or heat transfer. These are useful for adding safety ma
rgins into the analysis. In the case of pumps, the design factor multiplies the
head rise.
If modeling heat transfer, frequently you will know the upper and lower temperat
ure extremes in your pipe system. You can enter these in the Solution Control wi
ndow, and AFT Fathom will not allow the Solver to go outside of these bounds. Yo
u may want to enter data for the Temperature Limits when a model is having troub
le converging.
You can export your output to a delimited file for ready import into any spreads
heet software. This feature, Export Output, is available on the File menu when i
n the Output window.
You can save your output to a formatted file for archival of results. This featu
re, Save Output As, is available on the File menu when in the Output window.

You can keep a lengthy explanation or any other documentation about your model i
n the Reference Information section of the Output Control window. Names of proje
cts, individuals, and assumptions can all be kept with the model. This informati
on can then be included in your reports to improve tracking.
After specifying your preferred units, you can make all your output use these un
its. Open the Output Control window and select the "Use Preferred Units" button
on the Pipe or Junction tab.
You can find a description of any output parameter selecting the parameter in th
e Output Control window and looking at the description listed near the bottom of
the window.
You can find a description of any engineering unit by selecting the unit in the
Parameter and Unit Preferences window and looking at the Unit Description listed
near the bottom of the window.
You can completely customize your output report using the Output Control window
opened from the Analysis menu.
You can change how many digits are displayed in the Output window by specifying
the Minimum Number of Digits on the Format & Action tab of the Output Control wi
ndow.
You can change how many digits are displayed in the Visual Report window by spec
ifying the Minimum Number of Digits on General Display tab of the Visual Report
Control window.
You can show only certain pipes or junctions in the Output using the tools on th
e Show Selected Pipes/Jcts on the Output Control window.
You can change the Atmospheric Pressure level on the System Data tab of the Syst
em Properties window.
You can manually change the Workspace size using the Workspace Size window opene
d from the View menu.
You can show only certain pipes or junctions on the Workspace using the tools on
the Display Pipes and Junctions window opened from the View menu.
You can export selected Workspace or Visual Report content to a picture file usi
ng the Export As Picture tool on the File menu.
You can load a background picture into the Workspace using the Load Background P
icture tool on the File menu.
Graph Sets can be created and saved by the user using the tools in the Select Gr
aph Data window.

Das könnte Ihnen auch gefallen