Air handling units

Offer
Client
Project / commission
Responsible in our com
Your job number
Responsible in yr. com

Unit size exhaust air


Heat recovery
Air volume supply air
Air volume exhaust air
Unit type

Noname
Default

Pos
Date of make out

09.04.2010

Unit size supply air

KG 100

Casing design
Baseframe

KG 100
KGXD
6300 m/h
6300 m/h
Supply and exhaust air Side by
side
Standard doubleskinned
Baseframe 200 mm loose in
single pieces on palett , Sound
insulation on job site

Supply air:
(1) Short filter section
Initial resistance
Mat filter G4

24 Pa

Spare filter mat G4


Filter fastening

Selection resistance
74 Pa
Damper class 2 in accordance to DIN EN 1751,Q
external,860 x 860 / 7 Nm torqe / Damper shaft for
actuator 15 x 15 mm
Actuator Typ SF 24 S On/Off 24 V (20 Nm) mounted
Flexible connection Q
Access door

(2) KGXD horizontal


Fresh air pre-heating(heat
recovery)
Fresh air temperature
Exhaust air temperature
Relative humidity of exhaust
air
Data related to fresh air
temp.
Deepest fresh air temp.
Supply air temperature
Heat recovery figure
Heat exchang.,KGXD with bypass
Drain pan

-15,0 C
20,0 C
50,0 %

-15,5 C
11,1 C
74 %

Bypa damper ,Actuator Typ SF 24 S On/Off 24 V


(20 Nm) mounted

Heating capacity

54,7 kW

Condensate
Vitiated air temperature
Pressure drop(drop elim.)

23,2 kg/h
1,4 C
34 Pa

Relative humidity of vitiated


air
Pressure drop fresh air
Pressure drop exhaust air

100,0 %
186 Pa
186 Pa

Drop eliminator,T 400


Damper class 2 in accordance to DIN EN 1751,Q
external,860 x 860 / 7 Nm torqe / Damper shaft for
actuator 15 x 15 mm
Actuator Typ SF 24 S On/Off 24 V (20 Nm) mounted
Flexible connection Q

(3) Fan, Standard design


Air volume
External pressure
Internal pressure
Dynamic pressure
Total pressure
Impeller
Fan type
Discharge position

6300 m/h
450 Pa
441 Pa
45 Pa
936 Pa
Forward curved
TLZ 355
A

Fan - capacity
Fan - speed
Peripheral velocity
63 Hz
65 dBA

125 Hz
73 dBA

2,49 kW
1394 1/min
25,9 m/s
250 Hz
77 dBA

500 Hz
83 dBA

fan efficiency
Motor - capacity
Motor - speed
Motor - voltage
Motor-current*
Motor size
Total sound power
consumption of electrical
power
SFP (Specific fan power)

1000 Hz
85 dBA

2000 Hz
79 dBA

65,9
3.00
1500 IE 2
3*400
7,0
100
88,2
3,37

%
kW
1/min
V
A
dBA
KW

1,81 kW/(m/s)
0,503 W/(m/h)
4000 Hz
73 dBA

8000 Hz
64 dBA

____________________________________________________________________________________________________________________________________________________________________________________________

Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax. 08751/741573 oder 741800 Seite1/4
- (10) Version:2.0.211.3

*max. nom. current:motors used are slightly different.Choose range of overload relay so that stated nom.
current is within the upper third.
door protection grille
Motor protection,Thermistors(PTC) 1500
Protection grille,On access side
Access door
Isolator mounted and wired,AR 6/5,5

(4) Empty section with air diffusor


Selection resistance

32 Pa

(5) Heating section


Heat exchanger type
Connection (inlet/outlet)
Air-on temperature
Air-off temperature
Capacity (total)
Medium on temp.
Medium off temp.
Drain and vent valve

1 Cu/Al LT
1 0/0 Inch
11,0
24,0
28,1
80,0
60,0

C
C
kW
C
C

Medium flow rate


Antifreeze percentile
Air pressure drop
Pressure drop medium
Air velocity
Watercontent

1,23
0
30
4,5
2,7
4,6

m/h
%
Pa
kPa
m/s
l

(6) Cooling section


Heat exchanger type
Connection(inlet/outlet)

A Cu/Al KT
28 mm /35
mm
35,0
35,0
22,8
60,6
8,8
24,3
33,2

Evaporating temperature
Refrigerant

Air-on temperature
C
Relative humidity
%
Air-off temperature
C
Relative humidity
%
Capacity (latent)
kW
Capacity (sensitive)
kW
Capacity (total)
kW
Slide in rails
Drop eliminator,T 400,Plastic-drop eliminator (PP)

5,0 C
R410A

Max. operating pressure


Mass flow
Pressure drop(drop elim.)
Air pressure drop
Air velocity
Content

28
556,1
34
57
2,7
9,2

bar
kg/h
Pa
Pa
m/s
l

Alu-drain pan,Drain connection on connection side


Flexible connection Q

Exhaust air:
(2) KGXD horizontal
Technical data see supply air

(7) Short filter section


Initial resistance
Mat filter G4
Spare filter mat G4
Filter fastening

24 Pa

Selection resistance
Flexible connection Q
Access door

74 Pa

(8) Fan, Standard design


Air volume
External pressure
Internal pressure
Dynamic pressure
Total pressure
Impeller
Fan type
Discharge position

6300 m/h
350 Pa
322 Pa
45 Pa
717 Pa
Forward curved
TLZ 355
A

Fan - capacity
Fan - speed
Peripheral velocity
63 Hz

125 Hz

1,86 kW
1204 1/min
22,4 m/s
250 Hz

500 Hz

fan efficiency
Motor - capacity
Motor - speed
Motor - voltage
Motor-current*
Motor size
Total sound power
consumption of electrical
power
SFP (Specific fan power)

1000 Hz

2000 Hz

67,5
2.20
1500 IE 2
3*400
5,3
100
85,0
2,56

%
kW
1/min
V
A
dBA
KW

1,36 kW/(m/s)
0,378 W/(m/h)
4000 Hz

8000 Hz

____________________________________________________________________________________________________________________________________________________________________________________________

Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax. 08751/741573 oder 741800 Seite2/4
- (10) Version:2.0.211.3

62 dBA

70 dBA

74 dBA

80 dBA

82 dBA

76 dBA

70 dBA

61 dBA

*max. nom. current:motors used are slightly different.Choose range of overload relay so that stated nom.
current is within the upper third.
door protection grille
Motor protection,Thermistors(PTC) 1500
Protection grille,On access side
Access door
Isolator mounted and wired,AR 6/5,5

General accessory:
1 Pcs. Frost protection thermostat,Mounted
2 Pcs. Kugelsiphon saug- und druckseitig
2 Pcs. Pressure switch JDW-5 40 - 600 Pa,Filter control,
installed

1 Pcs. Three way control valve with actuator,VXG44.206.3


2 Pcs. Pressure switch JDW-5 40 - 600 Pa,Air flow
monitoring device, installed
1 Pcs. Pressure switch JDW-5 40 - 600 Pa,Frost
protection control, installed on the KGXD

Unit dimensions
Breadth
Breadth
Height Incl. baseframe
Baseframe 200 mm loose in
single pieces on palett ,
Sound insulation on job site

4160 mm
2000 mm
1200 mm

No.
Total weight

/
1111 kg

Summary of accessory
3 x Actuator Typ SF 24 S On/Off 24 V (20 Nm) mounted

____________________________________________________________________________________________________________________________________________________________________________________________

Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax. 08751/741573 oder 741800 Seite3/4
- (10) Version:2.0.211.3

____________________________________________________________________________________________________________________________________________________________________________________________

Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax. 08751/741573 oder 741800 Seite4/4
- (10) Version:2.0.211.3

Das könnte Ihnen auch gefallen