Sie sind auf Seite 1von 14

FINGERPRINT DOOR

LOCK
INSTRUCTIONS
MODEL FK-420

www.chinus.net

CHINUS TECHNOLOGY

Page 2

INDEX
SECTION
SECTION
SECTION
SECTION

1:
2:
3:
4:

SAMPLE OF PRODUCT-----------------------------------------------3
FUNCTION-----------------------------------------------------------------3
SKETCH MAP -------------------------------------------------------------3
OPERATION INSTRUCTIONS-----------------------------------------4

1. Fingerprint Management-----------------------------------------------------------------------------------------------4
1.1 Registration of fingers--------------------------------------------------------------------------------4
1.1.1. Registration of manager----------------------------------------------------------------------------------4
1.1.2. Registration of common user-----------------------------------------------------------------------------5
1.1.3. Digital inquiry ----------------------------------------------------------------------------------------------5
1.2 Deletion instructions---------------------------------------------------------------------------------- 6
1.2.1. Orientable deletion with finger--------------------------------------------------------------------------6
1.2.2. Orientable deletion with position------------------------------------------------------------------------6
1.2.3. Complete deletion------------------------------------------------------------------------------------------7
2. Lock Functions-----------------------------------------------------------------------------------------------7
2.1 Unlock with the registered fingers----------------------------------------------------------------- 7
2.2 State of always unlock-------------------------------------------------------------------------------- 7
2.3 Limited unlock----------------------------------------------------------------------------------------- 8
2.4 Lock from inside---------------------------------------------------------------------------------------8
3. Password-------------------------------------------------------- --------------------------8
3.1 Unlock with password-------------------------------------------------------------------------------- 8
3.2 How to set managers password-------------------------------------------------------------------- 8
3.3 How to set common users password-------------------------------------------------------------- 9

SECTION 5: FLOW DIAGRAM--------------------------------------------------------10


SECTION 6: DOORFRAME DRAWING --------------------------------------------11
SECTION 7: DOOR LOCK FITTINGS ----------------------------------------------11
SECTION 8: ATTENTIONS ------------------------------------------------------------12
SECTION 9: FAQS-----------------------------------------------------------------------13
SECTION 10: REGISTER LIST ---------------------------------------------------------14
NOTICESPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT
NOTICE AT ANY TIME. WE ARE NOT RESPONSIBLE FOR ANY
DAMAGES CAUSED BY USERS MISOPERATION.

NOTICE:
THERE IS NO BATTERY IN THE LOCK FOR THE CONVENIENCE OF
TRANSPORTATION, SO PLEASE INSTALL THE BATTERY FIRST ACCORDING
TO THE INSTALLATION CD. THEN START OPERATION WITH THIS MANUAL.

www.chinus.net

CHINUS TECHNOLOGY

Page 3

SECTION 1:

SAMPLE OF PRODUCT
Packing List

FK-420

SECTION 2:

Manual

Lock body

AA battery

Bolt board

Front panel

Bolt case

Back panel

Fittings

Mechanical
key

Quality
certificate

FUNCTION

Fingerprint capacity: 80 fingers;


Easy operation: humanity design for customer;
5 managers+75 common users management;
Unlock by fingerprint, ciphers and emergency keys;
Hotel lock with international standard;
Digital inquiry about storage quantity and locations;
Delete the appointed fingerprint;
Automatic alarm function;
Low power consumption design;

SECTION 3:

SPECIFICATIONS
Dimensions
Weight
Operating Voltage
Record Capacity
Dynamic Power Consumption
Static Power Consumption
Resolution
Acceptance Angle
FAR(False Acceptance Rate)
FRR(False Rejection Rate)
Matching Time
Operation Temperature
Operation Humidity

2507533mm
1.6 kg
4.76V(DC)
80pcs
140mA
18A
500dpi
40
0.0001%
0.01%
1s
-555
20%80%RH

SKETCH MAP

Red light
Green light
Button
Collecting window
Button

How to press finger on the collecting window:

www.chinus.net

CHINUS TECHNOLOGY

Page 4

SECTION 4:

OPERATION INSTRUCTIONS

1. Fingerprint Management

1.1 Registration of fingers:


You can register 80 fingers at most, including 5 managers and 75 common users.
5 managers can not only control the lock functions (e.g. unlock), but also the
fingerprint management (e.g. register, delete fingerprint); while 75 common
users can only operate the lock and they are not authorized to manage fingers.
ATTENTION: As the default setting, there is not any finger in the lock before it
is in use, so any finger can open it when it is electrified. Therefore, make sure
to register the fingers as soon as possible to ensure safety.

1.1.1. Registration of manager (1 ~ 5)

STEP After the lock is electrified, press button

to start. The collecting window turns

bright and the green light glitters.


STEP Press button

down and dont release the finger until 10 seconds pass. (The

red light glitters once after 5 seconds and it will glitter twice in all, with a di sound at the
same time. After the red light glitters twice, release your finger. The collecting window is
bright and the green light and red light glitter together).
STEP (If there is no registered finger in the lock, go straight to the next step.) The manager
presses his registered finger once to confirm. If it succeeds, there will be 3 continuous di
sounds and the green light glitters; if it fails, the red light turns bright and a di sound is
emitted to remind you of inputting correct manager finger.
STEP After confirmation, input finger needed to be registered, input each finger for 3
times. (The collecting window will be dark after you press finger each time to remind you of
releasing finger. After hearing the di sound, input the same finger again. 3 times in all).
STEP After 3 times input, three di sounds are emitted to remind you of registration are
complete. You can continue to input other managers (repeat the former procedure) or wait to
do other operations after the collecting window is dark. If the input fails, a di sound is given
and the red light turns bright to remind you of registering fingers again (repeat the last step).
NOTE: It is recommended to register not less than 2 managers for the convenience.
www.chinus.net

CHINUS TECHNOLOGY

Page 5

1.1.2. Registration of common user680


ONLY after the manager is registered, can the common users be registered.
STEP After the lock is electrified, press button

to start. The collecting window turns

bright and the green light glitters.


STEP Press button

down and dont release the finger until 5 seconds pass. (The

red light glitters once after 5 seconds, with a di sound at the same time. After that, release
your finger. The collecting window is bright and the green light and red light glitter together).
STEP The manager presses his registered finger once to confirm. If it succeeds, there will
be 3 continuous di sounds and the green light and red light glitter together; if it fails, the red
light turns bright and a di sound is emitted to remind you of inputting correct manager
finger.
STEP After confirmation, input finger needed to be registered, input each finger for 3
times. (The collecting window will be dark after you press finger each time to remind you of
releasing finger. After hearing the di sound, input the same finger again. 3 times in all)
STEP After 3 times input, three di sounds are emitted to remind you of registration are
complete. You can continue to input other users (repeat the former procedure) or wait to do
other operations after the collecting window is dark. If the input fails, a di sound is given
and the red light turns bright to remind you of registering fingers again (repeat the last step).
NOTE: It is recommended to register not less than 2 fingers for one user.

1.1.3. Digital inquiry: the amount and location of fingers can be inquired.
Amount inquiry of fingers
Amount of manager: When you register a new manager, presses button

as soon as

manager puts in his finger. The glittering times of light show the amounts of managers.

Amount of common users: when you register a new common user, press button

as soon as

manager puts in his finger. The glittering times of light show the amounts of managers
Location inquiry of registered fingers
After the registration (press the fingers needed to register in the third time), press button
immediately to demonstrate the position of the registered fingers.
The glittering times of green and red lights stand for the location of users: the glittering times of
green light are the tens value and red light are the units value. If the light does not glitter, the value
is zero (e.g. if the green light glitters twice and the red light glitters 3 times, the figure is 23)
www.chinus.net

CHINUS TECHNOLOGY

Page 6

1.2 Deletion instructions:


1.2.1. Orientable deletion: delete the appointed finger (finger must be input)
STEP After the lock is electrified, press button

to start. The collecting window turns

bright and the green light glitters.


STEP Press button

down and dont release the finger until 5 seconds pass. (The

red light glitters once after 5 seconds. After that, release your finger. The collecting window is
bright and the green light and red light glitter alternately).
STEP The manager presses his registered finger once to confirm. If it succeeds, there will
be 3 continuous di sounds and the green light and red light glitter together; if it fails, the red
light turns bright and a di sound is emitted to remind you of inputting correct manager
finger.
STEP After confirmation, input finger needed to be deleted once on collecting window.
STEP After that, three di sounds are emitted twice to remind you of deletion are
complete. You can continue to delete other users (repeat the former procedure) or wait to do
other operations after the collecting window is dark. If the input fails, a di sound is given
and the red light turns bright to remind you of deleting fingers again (repeat the last step)
1.2.2 Orientable deletion: delete the appointed finger according to its location (see 1.1.3
Location inquiry of registered fingers of last page for reference).
STEP After the lock is electrified, press button

to start. The collecting window turns

bright and the green light glitters.


STEP Press button

down and dont release the finger until 5 seconds pass. (The

red light glitters once after 5 seconds. After that, release your finger. The collecting window is
bright and the green light and red light glitter alternately).
STEP The manager presses his registered finger once to confirm. If it succeeds, there will
be 3 continuous di sounds and the green and red light glitter together; if it fails, the red light
turns bright and a di sound is emitted to remind you of inputting correct manager finger.
STEP After confirmation, input fingers location with two buttons (.e.g. if fingers
location is 23, press button
button

twice and press button

three times, then press

to confirm).

STEP Repeat the last step and input the location once again.
STEP The green light and red light will glitter to remind you of checking the location
(The glittering times of green and red lights stand for the location of users: the glittering times
of green light are the tens value and red light are the units value. If the light does not glitter,
the value is zero).
STEP After confirmation, press button
www.chinus.net

once to finish the deletion.


CHINUS TECHNOLOGY

Page 7

1.2.3. Complete deletion: delete all fingers, including managers and common users.
STEP After the lock is electrified, press button

to start. The collecting window turns

bright and the green light glitters.


STEP Press button

down and dont release the finger until 10 seconds pass. (The

red light glitters once after 5 seconds and it will glitter twice in all, with a di sound at the
same time. After the red light glitters twice, release your finger. The collecting window is
bright and the green light and red light glitter alternately).
STEP The manager presses his registered finger once to delete all common users. If it
succeeds, there will be 3 continuous di sounds and the green light and red light glitter
together; if it fails, the red light turns bright and a di sound is emitted to remind you of
inputting correct manager finger.
STEP The manager presses his registered finger once again to delete all managers. If it
succeeds, there will be 3 continuous di sounds and the green light and red light glitter
together; if it fails, the red light turns bright and a di sound is emitted to remind you of
inputting correct manager finger.

2. Lock Functions

2.1 Unlock with the registered fingers


STEP After the lock is electrified, press button

to start. The collecting window

turns bright and the green light glitters.


STEP Press the registered finger once in the center of collecting window with a little
strength.
STEP Lock opens and you can twist the door handle to unlock. After 3 seconds, it locks.

2.2 State of always unlock: the door will always be open.


STEP Open the lock first.
STEP After the lock is open, twist the lock handle downwards immediately or press down
button

. Dont release finger until 5 seconds pass (after 5 seconds, a di sound is

given to remind you of releasing finger).


STEP Under this condition, anyone can open it without registered finger.
STEP Twist the lock handle downwards or press down button

for another 5 seconds

to back into the normal status (Dont release finger until 5 seconds pass, after 5 seconds, a
di sound is given to remind you of releasing finger).
www.chinus.net
CHINUS TECHNOLOGY

Page 8

2.3 Limited unlock: only managers can open the lock


STEP Open the lock first.
STEP After the lock is open, twist the lock handle downwards immediately or press down
. Dont release until 10 seconds pass (after 5 seconds, a di sound is given and

button

another di sound is given after 10 seconds to remind you of releasing finger).


STEP After hearing the second di sound, release hands or finger. The collecting
window gets bright to remind you of inputting the managers finger.
STEP Input the managers finger in the center of collecting window. If it succeeds, the
collecting window will get dark. Only manager can open it next time.

2.4 Lock from inside:


Turn the deadbolt on the back panel to lock from inside. Under this status, fingerprint and
password cannot open it from outside. Only emergency keys take effect.

3. Password

Apart from the fingerprint and emergency keys, password is also available to open the door.
One manager password and one common user password can be set with two buttons. The
alternate

application of two buttons forms a 4-digit password.

3.1 Unlock with password:


STEP After the lock is electrified, press button

to start. The collecting window

turns bright and the green light glitters.


STEP Input passwords (start with button
button

, then input the password and end with

. The pressing times stands for the each figure of password. E.g. if the

password is 1234, you must press button


press button

once1, press button

three times3 and press button

STEP Press button

twice2,

four times4.

once to confirm.

STEP If the password is correct, the lock will open and close in 3 seconds.

3.2 How to set managers password


STEP After the lock is electrified, press button
www.chinus.net

to start. The collecting window


CHINUS TECHNOLOGY

Page 9

turns bright and the green light glitters.


STEP Press button

down and dont release the finger until 10 seconds pass. (The

red light glitters once after 5 seconds and it will glitter twice in all, with a di sound at the
same time. After the red light glitters twice, release your finger. The collecting window is
bright and the green light and red light glitter together).
STEP The manager presses his registered finger once to confirm. If it succeeds, there will
be 3 continuous di sounds and the green light glitters; if it fails, the red light turns bright
and a di sound is emitted to remind you of inputting correct manager finger.
STEP After confirmation, input password needed to be registered, (see the password
input in last page for reference, start with button
Press button

and end with button

).

once to confirm.

STEP Repeat the last step and input the password again.

3.3 How to set the password of common users


STEP After the lock is electrified, press button

to start. The collecting window

turns bright and the green light glitters.


STEP Press button

down and dont release the finger until 5 seconds pass. (The

red light glitters once after 5 seconds, with a di sound at the same time. After that, release
your finger. The collecting window is bright and the green light and red light glitter together).
STEP The manager presses his registered finger once to confirm. If it succeeds, there will
be 3 continuous di sounds and the green light glitters; if it fails, the red light turns bright
and a di sound is emitted to remind you of inputting correct manager finger.
STEP After confirmation, input password needed to be registered, (see the password
input in last page for reference, start with button
Press button

and end with button

).

once to confirm.

STEP Repeat the last step and input the password again.
ATTENTIONS:
All operation will terminate if no operation continues in 9 seconds.
When it starts with low power, the red light will glitter and 3 di sounds will be given.
It will give an alarm automatically in 5 seconds if it is prized or doesnt close well.
The registration of common users must be under the authentication of manager.
Power consumption is a little different according to different models.
There is no initial password. Password can not be revised but to be covered by the new
one. After complete deletion, all passwords are erased.
www.chinus.net

CHINUS TECHNOLOGY

Page 10

SECTION 5:

FLOW DIAGRAM
Registration

Registration of
common users

Unlock

Registration of
managers

Press to start
Press to start
Pressfor 5s

Pressfor 10s

Input finger

Input password

Manager press
finger once

Pass

Pass
Door unlock
Twice inout the
4-digit
password
to
register
the
password

Press finger 3 times


Unlock with handle
Next registration
Lock closes in 3s

Lock Operation
Always unlock

Press down
handle or
buttonfor 5s
after lock
opens

Deletion

Orientable
Deletion

Limit unlock
Only manager can
unlock

Complete
Deletion

Press to start

Pressfor 5s

Press down
handle or button
for 10s after
lock opens

Pressfor 10s

Manager press finger once


Pass

Always unlock

Manager press
finger once

Press down
handle or
buttonfor
another 5s

Press fingers
position
and
press to
confirm

Pass
Press finger

Delete common user

Manager press finger


Pass

Normal status

www.chinus.net

Limit unlock

Delete finger

Delete finger

Delete manager

CHINUS TECHNOLOGY

Page 11

SECTION 6:

DOOR LOCK FITTINGS

1
2

No.
1
2
3
4
5
6
7
8
9
10
11
12

12 11 10

13
14

Name &
specification
M3*10flat head
bolt
Battery case
M5*60flat head
bolt
Back panel
Front panel
Round spring
Foursquare stick
Doorframe
Lock body
M4*30 bolt
Bolt panel
M4*6 flat head
bolt
M4*30 bolt
Door bolt case

Quantity
1
1
4
1
1
2
2
1
1
2
1
2
2
1

14 13

SECTION 7: DOORFRAME

In side door drilling

www.chinus.net

DRAWING

Outsidedoor drilling

CHINUS TECHNOLOGY

Page 12

Foursquare
stick
Sheathe

SECTION 8: ATTENTIONS
FINKIN Fingerprint locking devices are used by people with the need for a more
secure working environment. To ensure a long lasting trouble free use of this
product, please read the following cautions. Keep away from:
Strong magnetism
Strong radiation
Salt
Dampness
High temperature
Low temperature
Direct sunshine
1. FINKIN locking devices retain many characteristics of fingerprints. There
are no pictures of them, so there is not a privacy problem.
2. When used, your finger must not be too dry or too damp. If your finger is too
dry, simply touch your forehead or nose to make a primary contact.
3. Be careful to not scratch the fingerprint scanning window. Please keep the
window clean by using a soft damp cloth. Do not use any type of abrasive
cleaners as they will damage the scanning window.
4. If the door is distorted or becomes warped, it will cause too much friction
between the lock bolt trough and dead bolt case. So the locking device works
properly, you will need to adjust the position of the lock trough and the dead
bolt case.
5. Beeping alarm will sound when battery is low on power, change to a new
www.chinus.net

CHINUS TECHNOLOGY

Page 13

battery.
6. Key can open door at any status.
7. For security, every user should use more than two fingerprints.
8. If there are complications on opening the door lock, contact the local
distributor for assistance. Do not try to repair the fingerprint lock assembly.
SECTION 9:

FAQs

QUESTION: Fingerprint lock works with batteries, so what should we do if the batteries fail?
ANSWER: The lock is supplied by four AA alkaline batteries. The door lock alarm will sound
automatically. Replace the old battery with new batteries. When the alarm is first sounds, you can
use the door lock approximately 30 more times. You can have access through the door by key if
necessary.
QUESTION: My finger was injured or cut, how can I open the door?
ANSWER: Normally small cuts will not restrict access, larger cuts will require you gain entrance
with your passage key.
QUESTION: Why is it necessary to input my fingerprint three times during programming of the
lock mechanism?
ANSWER: On registering the finger, our model needs 3 times to collect the fingerprint
characteristics to ensure their accuracy, while when we open it, our model just compares the image
with the collected characteristic. Therefore, once is enough.
QUESTION: Why does the door not unlock with my registered finger?
ANSWER: There are four basic reasons for this:
a) The fingerprint used is not the finger recorded.
b) Your fingerprint could be too dry or too damp.
c) Finger was not pressed firmly enough on the scanning window, use additional pressure..
d) The original fingerprint was not imprinted in the memory firmly enough and the system cannot
identify it. It is best to use two fingerprints when programming, so there would be a back up.
Re-program your fingerprint lock with new use prints.

QUESTION: After I press button

and press button

for a few seconds, why cant I

get into the process of fingerprint deletion?


ANSWER: Before you press button

, you may touch this button for a short time carelessly.

In such a situation, the system needs passwords to continue. Therefore, you have to wait 9 seconds
until the light extinguishes. If you want to delete fingerprints, please press button

directly for

5 or 10 seconds after operation starts.


www.chinus.net

CHINUS TECHNOLOGY

Page 14

SECTION 10:
User

REGISTER LIST
Position
01
02

Manager

03
04
05
06
07
08
09
10
11

Common
users

12

Light I.D.

User Name

New user name

Green
bright red 1
Green
bright red 2
Green
bright red3
Green
bright red 4
Green
bright red 5
Green
bright red 6
Green
bright red 7
Green
bright red 8
Green
bright red 9
Green 1 red
bright
Green 1 red
1
Green 1 red
2

77
78
79
80

Green 7 red
7
Green 7 red
8
Green 7 red
9
Green 8 red
bright

Remarks:
1. Above register is for fingerprint user access history to assist door lock administrator to add
new users or to delete a user.

2. 78 (Green 7 red 8) express: Green light will glitter 7times and red light glitter 8 times.
80 (Green 8 red bright) express: Green light will glitter 8 times and red light keeps bright.
Bright means the light is a steady bright light.

www.chinus.net

CHINUS TECHNOLOGY