Data Sheet 1.12-1/1 1)

Metal Tank Test Transformer and


Transformer Cascade,
Type PEO
Description
Metal tank transformers have an earthed tank (very space saving in the HV laboratory) and a bushing to air (on
request a bushing to a SF6-insulated, completely metal-enclosed HV test system). They are provided for indoor
(type PEO) or outdoor (type FPEO) operation and well suited for heavy climatic conditions.
Metal tank transformers are designed for higher power and for continuous operation. For short-time operation
higher currents than specified in this Data Sheet can be supplied. The exciter winding is divided into two parts
which can be connected in series or in parallel for an improved voltage adjustment and power adaptation. The
low internal partial discharge recommends the application of metal tank transformers not only for test line
operation, wet and pollution testing (which requires higher currents), but also for PD testing.
For the generation of voltages in the range of megavolts, transformers can be cascaded (see figure 4).
Table 1: Operating conditions

Frequency

Hz

Temperature range for indoor installation (type PEO)


Temperature range for outdoor installation (type FPEO)
Average temperature per day
Relative humidity
Height above sea level
Duty cycle

C
C
C
%
m

50 / 60
5 40
-5 40
30
90
1000
Continuous operation

Table 2: Standard climatic conditions for bushing

Temperature
Absolute pressure
Absolute humidity

C
hPa
g/m3

20
1013
11

The transformers are designed with low core induction to guarantee a sine-wave form of the output voltage with
lower than 5 % of harmonic distortion in the test system. To prevent increasing of harmonics due to resonant
phenomena the systems may be provided with harmonic filters.
The high-voltage windings are of layer type and they are completely shielded to achieve a high-electric strength
against transient overvoltages. The windings are short-circuit proof. For more details ask HIGHVOLT directly.
Special design and accessories on request:
design for short-time operation with higher currents
position of the bushing different from standard
rollers for transportation on floor (smaller types) or rails (larger types) or air cushions (larger types)
base frame as a oil collecting trough if demanded for emergency cases (smaller types)
1)

The prior version of the Data Sheet was 1.12/3.

HIGHVOLT Prftechnik Dresden GmbH 2012/08 sheet_PEO Subject to change without prior notice

1/4

Table 3: Main parameters

Type

2)3)

PEO 60/60
PEO 300/60
PEO 100/100
PEO 500/100
PEO 200/200
PEO 400/200
PEO 1000/200
PEO 300/300
PEO 600/300
PEO 2000/300
PEO 400/400
PEO 800/400
PEO 2000/400
PEO 500/500
PEO 1000/500t
PEO 2000/500
PEO 600/600
PEO 1200/600
PEO 2000/600t
PEO 1500/750t
PEO 1000/800
2 x PEO 1000/500t
2 x PEO 2000/600t
2 x PEO 1500/750t
3 x PEO 2000/600t
FPEO 60/60
FPEO 300/60
FPEO 100/100
FPEO 500/100
FPEO 200/200
FPEO 400/200
FPEO 1000/200
FPEO 300/300
FPEO 600/300
FPEO 2000/300
FPEO 400/400
FPEO 800/400
FPEO 2000/400
FPEO 500/500
FPEO 1000/500t
FPEO 2000/500
FPEO 600/600
FPEO 1200/600
FPEO 2000/600t
FPEO 1500/750t
2 x FPEO 1000/500t
2 x FPEO 2000/600t
2 x FPEO 1500/750t
3 x FPEO 2000/600t

Rated output
voltage

Rated output
4)
current

Rated output
power

Input
5)
voltage

kV
60
60
100
100
200
200
200
300
300
300
400
400
400
500
500
500
600
600
600
750
800
1000
1200
1500
1800
60
60
100
100
200
200
200
300
300
300
400
400
400
500
500
500
600
600
600
750
1000
1200
1500
1800

A
1
5
1
5
1
2
5
1
2
6.7
1
2
5
1
2
4
1
2
3.3
2
1.25
1
2
1
1.25
1
5
1
5
1
2
5
1
2
6.7
1
2
5
1
2
4
1
2
3.3
2
1
2
1
1.25

kVA
60
300
100
500
200
400
1000
300
600
2000
400
800
2000
500
1000
2000
600
1200
2000
1500
1000
1000
2400
1500
2250
60
300
100
500
200
400
1000
300
600
2000
400
800
2000
500
1000
2000
600
1200
2000
1500
1000
2400
1500
2250

V
400
400
400
500
400
400
500
400
500
6000
400
500
6000
500
6000
6000
500
6000
6000
6000
6000
6000
6000
6000
6000
400
400
400
500
400
400
500
400
500
6000
400
500
6000
500
6000
6000
500
6000
6000
6000
6000
6000
6000
6000

Impedance voltage
50 Hz
%
6.3
6.5
5.5
7
5
5.6
5.7
5.5
6.3
7
4.5
6.8
5.1
6
5.4
6.8
5.8
5
5.8
6.2
4.8
17
19
22
28
6.3
6.5
5.5
7
5
5.6
5.7
5.5
6.3
7
4.5
6.8
5.1
6
5.4
6.8
5.8
5
5.8
6.2
17
19
22
28

60 Hz
%
7.6
7.8
6.6
8.4
6
6.7
6.8
6.6
7.6
8.4
5.4
8.2
6.1
7.2
6.5
8.2
7
6
7
7.4
5.8
20
23
26
34
7.6
7.8
6.6
8.4
6
6.7
6.8
6.6
7.6
8.4
5.4
8.2
6.1
7.2
6.5
8.2
7
6
7
7.4
20
23
26
34

2)

The type designation PEO characterizes the indoor type. All types can be supplied in outdoor design with the designation
FPEO instead of PEO. The first figure is the rated test power, the second the rated voltage.
3)
The letter "t" means the transformer is equipped with a transfer winding for cascades.
4)
The transformers are designed for continuous operation (24h per day), higher currents for short-time operation can be
generated. Related details on request.
5)
The adaptation to different voltages on request.

HIGHVOLT Prftechnik Dresden GmbH 2012/08 sheet_PEO Subject to change without prior notice

2/4

Table 4: Design, dimensions and weight

Type
PEO 60/60
PEO 300/60
PEO 100/100
PEO 500/100
PEO 200/200
PEO 400/200
PEO 1000/200
PEO 300/300
PEO 600/300
PEO 2000/300
PEO 400/400
PEO 800/400
PEO 2000/400
PEO 500/500
PEO 1000/500t
PEO 2000/500
PEO 600/600
PEO 1200/600
PEO 2000/600t
PEO 1500/750t
PEO 1000/800
2 x PEO 1000/500t
2 x PEO 2000/600t
2 x PEO 1500/750t
3 x PEO 2000/600t
FPEO 60/60
FPEO 300/60
FPEO 100/100
FPEO 500/100
FPEO 200/200
FPEO 400/200
FPEO 1000/200
FPEO 300/300
FPEO 600/300
FPEO 2000/300
FPEO 400/400
FPEO 800/400
FPEO 2000/400
FPEO 500/500
FPEO 1000/500t
FPEO 2000/500
FPEO 600/600
FPEO 1200/600
FPEO 2000/600t
FPEO 1500/750t
2 x FPEO 1000/500t
2 x FPEO 2000/600t
2 x FPEO 1500/750t
3 x FPEO 2000/600t
6)

Installation

Design
6)
group

Bushing
7)
position

Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor

H
H
H
H
H
H
A
T
A
A
T
T
A
T
A
A
A
A
A
A
A
C
C
C
C
H
H
H
H
H
H
A
T
A
A
T
T
A
T
A
A
A
A
A
A
C
C
C
C

v
v
v
v
h
h
h
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
v
v
v
v
h
h
h
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s

Length x Width x Height


(approx.)

8)

mm
850 x 770 x 1600
1300 x 1050 x 1550
1050 x 900 x 2200
1900 x 950 x 2550
2800 x 1200 x 1600
3300 x 1400 x 1800
3100 x 1750 x 2600
3300 x 1500 x 1800
3500 x 1500 x 2000
5400 x 2400 x 3200
5500 x 2100 x 2500
4400 x 1900 x 2800
6300 x 2850 x 3200
5500 x 2100 x 2500
5200 x 2300 x 3400
6300 x 2800 x 3900
6300 x 2100 x 2800
6100 x 2600 x 3500
7500 x 2800 x 3200
7800 x 2900 x 4800
5600 x 2850 x 2850
13000 x 6200 x 7800
15000 x 6200 x 7800
16000 x 6200 x 9500
24000 x 6200 x 11000
850 x 770 x 1600
1300 x 1050 x 1550
1050 x 900 x 2200
1900 x 950 x 2550
2800 x 1200 x 1600
3300 x 1400 x 1800
3100 x 1750 x 2600
3300 x 1500 x 1800
3500 x 1500 x 2000
5400 x 2400 x 3200
5500 x 2100 x 3200
4400 x 1900 x 2800
6300 x 2850 x 3200
5500 x 2100 x 3200
5200 x 2300 x 3400
6300 x 2800 x 3900
6300 x 2100 x 2800
6100 x 2600 x 3500
7500 x 2800 x 3200
7800 x 2900 x 4800
13000 x 6200 x 7800
15000 x 6200 x 7800
16000 x 6200 x 9500
24000 x 6200 x 11000

Total
weight
(approx.)
kg
720
2000
1100
3200
2500
4300
6800
4300
7800
15000
9700
12000
25000
9700
18000
22200
12100
23000
25800
29500
22000
42000
58000
64000
98000
720
2000
1100
3200
2500
4300
6800
4300
7800
15000
10100
12000
25000
10100
18000
22200
12100
23000
25800
29500
42000
58000
64000
98000

Weight
of oil
(approx.)
kg
180
600
400
1200
900
1000
1850
1100
1900
3700
2600
3400
9200
2600
5400
6200
4800
7000
8700
10200
8400
10800
17400
20400
26100
180
600
400
1200
900
1000
1850
1100
1900
3700
2700
3400
9200
2700
5400
6200
4800
7000
8700
10200
10800
14000
20400
21000

The design groups are:

A -steel tank with conservator


C -cascade.
H -hermetically sealed tank, corrugated tank
T -steel tank without conservator, indoor application only, in case of outdoor operation group A
7)
The bushing is arranged in: h -horizontal position
s -slanting position
v -vertical position
8)
including bushing

HIGHVOLT Prftechnik Dresden GmbH 2012/08 sheet_PEO Subject to change without prior notice

3/4

Figure 1: Design group H

Figure 2: Design group T

Figure 3: Design group A

Figure 4: Design group C

Type designation
Indoor installation:

Outdoor installation:

PEO a/b

FPEO a/b

a = rated output power in kVA


b = rated output voltage in kV

a = rated output power in kVA


b = rated output voltage in kV

HIGHVOLT Prftechnik Dresden GmbH 2012/08 sheet_PEO Subject to change without prior notice

4/4

Das könnte Ihnen auch gefallen