"A" Series Piston Pumps

A10-FR01

PISTON
PUMPS

Spare Parts List

CAUTION

A10-FR01-12/1280/1290

When making replacement of seals or bearings,


please do it carefully after reading through the
relevant instructions in the Operator's Manual.
X

37 41

64 39 23 37 36 35 38

25

23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7

24

6
5

34 33 32 31 30 29 28 27 26 1

51 52 53 54 55 56 57 58 59 60 61

63

62

Section X-X
List of Seals & Bearings
Qty.
Item

Name of Parts

Part Numbers

C&H

Oil Seal

TCN24408Y

O-Ring

SO-NA-G50

Bearing

6204

16

O-Ring

SO-NB-P14

20

O-Ring

SO-NB-G120

23

O-Ring

SO-NB-P6

33

Bearing

HMK1215

37

O-Ring

SO-NB-P12

54

O-Ring

SO-NA-A018

62

O-Ring

SO-NB-P10

64

O-Ring

SO-NB-P9

When ordering seals, please specify the seal kit number from the table below.

List of Seals Kits


Pump Model Numbers

Seal Kit Numbers

A10-FR01B-12/1280/1290

KS-A10-01B-12

A10-FR01C-12/1280/1290
A10-FR01H-12/1280/1290

No.24

KS-A10-01H-12

Pres. Adj. Range

"A" Series Piston Pumps


A16 / A22 / A37 / A56--R-01

PISTON
PUMPS

Spare Parts List


A16/A22/A37/A56--R-01---K-32/3280/3290
25 40

35

43

44

25 11

56
60 31

52

22

32
27
61

58

29
57
51
5
55
54
49
53

38 43

37

15 18

24

12 34

39

16

41

36

28

50

42

30

19 33 20

17

10 21

47
46

CAUTION

23

When making replacement of seals or bearings,


please do it carefully after reading through the
relevant instructions in the Operator's Manual.

45
14
13

Section X-X
List of Seal and Bearings
Part Numbers

Item

Name of Parts

A56--R-01

Qty.

27

Bearing

28

Bearing

6307

NUP 207E

HMK 2025V2

HMK 2530V2

29

Oil Seal

TCN 355511

TCN 355511

30
35

1303-PK211969-1

1316-PK211970-9

1307-PK211971-7

SO-NA-G25

SO-NB-G30

SO-NA-P36

36

O-Ring

SO-NB-P12

37

O-Ring

SO-NB-P9

38

O-Ring

SO-NA-A017

39

Seal Washer

W8

60

O-Ring

SO-NB-P14

61

O-Ring

A16--R-01

A22--R-01

A37--R-01

Z30-1303-PK410300-8
TCN 254511

Gasket
O-Ring

6305
HMK 1715

SO-NB-P10A

SO-NA-G55

1
SO-NA-G75

When ordering seals, please specify the seal kit number from the table below.

List of Seal Kits


Pump Model Numbers

Seal Kit Numbers

A16--R-01--K--32

KS-A16-01-32

A37--R-01--K--32

KS-A37-01-32

A22--R-01--K--32
A56--R-01--K--32

KS-A56-01-32

No.25

"A" Series Piston Pumps


A70 / A90-R01

PISTON
PUMPS

Spare Parts List

CAUTION

A70/A90-R01S-60/6080/6090

When making replacement of seals or bearings,


please do it carefully after reading through the
relevant instructions in the Operator's Manual.
25 26 27 28 29 30 31 32 33
63
55

27

53

26

55

37

12

32

56

36

67

4
51

46

35

42

P
Q

45

60

64

62

34

54

40

47

38
48
52
66
39

23

24

58

19

44

43

11

21

20

25

61

33

31

13

18

28

59

10

54

50

44

68

16

22

15 14

44

Detail "A"

69

17

29

65

30

70

Section Z-Z

Section X-X
(Only for "A70")

Section X-X
List of Seals and Bearings

Part Numbers

Item

Name of Parts

A70-R01S

A90-R01S

Qty.

Gasket

1314E-PK211972-5

1310E-PK211973-3

22

Back Up Ring

1310E-PK412440-0

1310E-PK412440-0

38

Bearing

NUP 208EX50

NUP 210E

39

Needle Bearing

HMK 3030V2

HMK 3530BV2

40

Oil Seal

TCN 355511

TCN 456812

42

O-Ring

SO-FA-G85

SO-FA-G95

43

O-Ring

SO-NA-P18

SO-NA-P18

44

O-Ring

SO-NB-P9

SO-NB-P9

67

O-Ring

SO-NB-P14

SO-NB-P18

68

Seal Washer

W10

70

O-Ring

1
SO-NB-P5

List of Seal Kits


Pump Model Numbers

Seal Kit Numbers

A70-R01S-60

KS-A70-01-60

A90-R01S-60

No.26

KS-A90-01-60

When ordering the seals, please specify the seal kit number
from the table left.

"A" Series Piston Pumps


A145-R01

PISTON
PUMPS

Spare Parts List

CAUTION

A145-R01S-60/6080/6090

When making replacement of seals or bearings,


please do it carefully after reading through the
relevant instructions in the Operator's Manual.

58 69 51 52 36 65 62 46 65 14 8
25
X

7 33 16 3 60 37 73 59 5

61
9

59

44

67

54

70

41

35

68

27

29

64

74

39

30

57

40

28

53 2 34 26 11 6

1 32 38 10 13 12 16 71 31 72
26 27 28 29 30 31 32 33 34

24

62

56

19

17

50

48

66

23
57

63 15 46

20
21 45

43

18

22

59

47

49
Detail "A"

Section X-X

List of Seals and Bearings


Item

Name of Parts

Part Numbers

Qty.

Gasket

1312-PK211974-1

15

Back Up Ring

1310E-PK412440-0

39

Bearing

NUP 2211ET2

40

Needle Bearing

8Q-NK385530

41

Oil Seal

TCN 507212

43

O-Ring

S-31.5 (NBR, Hs70)

44

O-Ring

SO-FA-G105

45

O-Ring

SO-NA-P18

46

O-Ring

SO-NB-P9

47

O-Ring

SO-NB-A017

48

O-Ring

SO-NB-A016

49

Back Up Ring

For SO-NB-A017

50

Back Up Ring

For SO-NB-A016

73

O-Ring

SO-NB-P18

When ordering seals, please specify the kit number "KS-A145-01-60".

No.27

"A" Series Piston Pumps


Variable Displacement-Single Pumps
Solenoid Two Pressure Control Type
A16 / A22 / A37 / A56 / A70 / A90 / A145

PISTON
PUMPS

Specifications
Graphic Symbol

PH

Output Flow

PL

Performance Characteristics

M
O

SOL
"OFF"

SOL
"ON"

PL
Pressure

PH

Specifications
Model Numbers

A16--R-02--K-32

A22--R-02--K-32
A37--R-02--K-32
A56--R-02--K-32
A70-R02S-60
A90-R02S-60

A145-R02S-60

Operating Pres.
MPa (PSI)

Geometric
Displacement
cm3/rev
(cu. in. /rev)

Minimum
Adj. Flow
cm3/rev
(cu. in. /rev)

Rated

Minimum
Adj. Pres.
1
Intermittent MPa (PSI)

50

A120
AC
A200

A240
D12
DC
D24
(K Series)
D48
ACDC R100
Rectified R200

60
50
60
50
60
50
60

50 /60

Flange
Mtg.

Foot
Mtg.

4 (.244)

16 (2320)

21 (3050)

1.2 (170)

1800

600

24.5 (54.0) 26.7 (58.9)

6 (.366)

16 (2320)

16 (2320)

1.2 (170)

1800

600

24.5 (54.0) 26.7 (58.9)

36.9 (2.25)

10 (.61)

16 (2320)

21 (3050)

1.2 (170)

1800

600

36 (79.4) 40.3 (88.9)

56.2 (3.43)

12 (.73)

16 (2320)

21 (3050)

1.2 (170)

1800

600

43 (94.8) 47.3 (104)

70.0 (4.27)

30 (1.83)

25 (3630)

25 (3630)

2 (290)

1800

600

63.5 (140) 75.5 (166)

91.0 (5.55)

56 (3.42)

25 (3630)

25 (3630)

2 (290)

1800

600

80.5 (178) 101 (223)

145 (8.85)

83 (5.06)

25 (3630)

25 (3630)

2 (290)

1800

600

97.5 (215) 122.5 (270)

2. When operating the pump exceeding the rated pressure, operating


conditions are restricted. Refer to page 6 for the details.

Voltage (V)
Current & Power at Rated Voltage
Source Serviceable Inrush
Holding
Power
Rating
Range
(A)
(A)
(W)
80 -110
0.51
2.42
100
0.37
2.14
100
90 -120
0.44
2.35
110
96 -132
0.42
2.02
120
108 -144
0.31
1.78
160 -220
0.25
1.21
200
0.19
1.07
200
180 - 240
0.22
1.18
220
192 - 264
0.21
1.01
240
216 - 288
0.15
0.89
10.8 - 13.2
2.45
12
21.6 - 26.4
1.23
24
29
43.2 - 52.8
0.61
48
90 - 110
0.33
100
29
180 - 220
0.16
200

Inrush current in the above table shows rms values at maximum stroke.

No.28

Min.

15.8 (.964)

Solenoid Ratings

A100

Max.

Approx. Mass
kg (lbs.)

22.2 (1.355)

1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.

Electric Coil Frequency


Source Type
(Hz)

Shaft Speed Range


r/min

"A" Series Piston Pumps


Solenoid Two Pressure Control Type
A16 / A22 / A37 / A56 / A70 / A90 / A145
Model Number Designation

PISTON
PUMPS

Model Number Designation

A16
Series
Number

-F

-R

-02

-S

-K

-A100

-32

Mounting

Direction of
Rotation

Control
Type

Port
Position

Shaft
Extension

Coil Type of
Solenoid Valve

Design
Number

Design
Std.

A16
(15.8 cm3/rev)
A22
(22.2 cm3/rev)
A37
(36.9 cm3/rev)

F:
Flange
Mtg.
L:
Foot
Mtg.

Viewed from
Shaft End

R:
Clockwise
(Normal)

32
02:
Solenoid Two
Prsuure Control
Type

None:
Axial Port

S:
Side Port

A56
(56.2 cm3/rev)

A70
Series
Number
A70
(70 cm3/rev)
A90
(91.0 cm3/rev)
A145
(145 cm3/rev)

AC
A100,A120
A200,A240

DC
K:
Keyed Shaft D12,D24
D48
(ACDC Rectified)
R100,R200

32
Refer to

32

32

-F

02

A100

-60

Mounting

Direction of
Rotation

Control
Type

Port
Position

Coil Type of
Solenoid Valve

Design
Number

Design
Std.

F:
Flange Mtg.
L:
Foot Mtg.

Viewed from
Shaft End
R:
Clockwise
(Normal)

02:
Solenoid Two
Prsuure Control
Type

1. Available to supply pump with anti-clockwise rotation. Consult


Yuken for details.

AC
A100,A120
A200,A240
S:
Side Port

DC
D12,D24
D48
(ACDC Rectified)
R100,R200

60

60

Refer to

60

3. Design Standards: None ........... Japanese Standard "JIS"


80 ............... European Design Standard
90 ............... N. American Design Standard

2. The axial port is not available to the N. American Design Standard of


A37 and A56 series.

Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 10 to 16.

Pipe Flange Kit


For pipe flange, refer to form of pressure compensator type on page 7.

No.29

"A" Series Piston Pumps


A16 / A22--R-02

PISTON
PUMPS

Installation Drawing
Axial Port Type
Flange Mtg.: A16-F-R-02-K--32/3290
A22-F-R-02-K--32/3290

172
(6.77)
Pilot Port "PP1"
"E" Thd.

23
(.91)

106
(4.17)
130
(5.12)
188
(7.40)

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

3(.12)

R14(R.55)
95(3.74) Dia.

A16-F-R-02-K--3280
A22-F-R-02-K--3280

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 in.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
135
80.1
(5.31)
(3.15)
d
53
(2.09)

161
(6.34)

Flow Adj. Screw


5(.20) Hex. Soc.

Suction Port
19(.75) Dia.

22.2(.874)
65
(2.56)

47.6
(1.874)

DEC.

"F" Thd. 17(.67) Deep


8 Places
Discharge Port
19(.75) Dia.

View Arrow X

Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
Works at Solenoid
Energised

177
(6.97)
195.5
(7.70)

12
(.47)
12
(.47)

Lock Nut
17(.67) Hex.

16
(.63)

18(.71)

96
(3.78)

19.05(.7500)
19.02(.7488) Dia.
21.24(.836)
21.08(.830)
82.55(3.250)
82.50(3.248) Dia.

273.5
(10.77)
145
(5.71)
117
(4.61)
62
(2.44)

Lock Nut
14(.55) Hex.

Fully Extended
2
256.5(10.10)
Pilot Port "PP2"
141.5
"E" Thd.
(5.37)
90
138.5
77
(3.54)
(5.45)
(3.03)
44.5(1.75)
Electrical Conduit
112
3
53
Connection
(4.41)
(.12) (2.09)
"D" Thd. (Both Ends)
59
6.5
(2.32) (.26)
1
Filling Port
26.5
[22(.87) Hex. Head Plug Furnished]
"PP1"
(1.04)
Drain Port
"PP2"
"C" Thd.
4.79(.1886)
25
4.76(.1874)
(.98)

mm (IN.)

Model Numbers

A16/A22-F-R-02-K-A-

194 (7.64)

182. (7.17)

39 (1.54)

3280

205 (8.07)

193 (7.60)

39 (1.54)

A16/A22-F-R-02-K-D-

208 (8.19)

186.2 (7.33)

53 (2.09)

For other dimensions, refer to 32/3290 design.


1. Install the pump so that the "Filling Port" is at the
top.
2. The pilot port provided is for connecting a control
valve, if multistage pressure control is required.

Model Numbers
A16/A22-F-R-02-K--32

A16/A22-F-R-02-K--3280

A16/A22-F-R-02-K--3290

"C" Thd.

"D" Thd.

Rc 3/8

G 1/2

Rc 1/4
1/4 BSP. Tr

3/8 BSP.F
3/8 NPT

"E" Thd.

1/2 NPT

1/4 NPT

"F" Thd.
M10
3/8-16 UNC

DIMENSIONS IN MILLIMETRES (INCHES)


Side Port Type

Foot Mounting Type

Port mounting dimensions are the same as those of pressure compensator


model. Refer to page 18 for port mounting dimensions.

Mounting bracket is common to that of pressure compensator model.


Refer to page 18 for the dimensions of mounting bracket.

No.30

"A" Series Piston Pumps


A37--R-02

PISTON
PUMPS

Installation Drawing
Side Port Type
Flange Mtg. : A37-F-R-02-S-K-32/3290

32(1.26)

14
(.55)
30.2
12
(1.189) (.47)
178.5
(7.03)

Pilot Port "PP1"


"E" Thd.

R14(R.55)
120(4.72) Dia.
146.5
(5.75)
174
(6.85)
202
(7.95)

A37-F-R-02-S-K-3280

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
77.1
158
(3.04)
(6.22)
d
50
(1.97)

165
(6.50)

Flow Adj. Screw


5(.20) Hex. Soc.

b
86
(3.39)

"F" Thd. "H" Deep


4 Places

DEC.

6.38(.2512)
6.35(.2500)

105
(4.13)

Front Side : Discharge Port 32(1.26) Dia.


Rear Side : Suction Port 32(1.26) Dia.

26
13
(.51) (1.02)
Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
6(.24)
Works at Solenoid
Energised

Electrical Conduit
Connection
"D" Thd. (Both Ends)

Drain Port
"C" Thd.

22.23(.8752)
22.20(.8740) Dia.
25.01(.985)
24.85(.978)

289.5
(11.40)
149
(5.87)
121
(4.76)
68
(2.68)
58.7
(2.311)

"PP2"

Filling Port
[22(.87) Hex. Head Plug Furnished]

(2.91)
6
50
(.24) (1.97)

181
(7.13)
199.5
(7.85)

"PP1"

25
(.98)

Lock Nut
14(.55) Hex.

Pilot Port "PP2"


"E" Thd.
74

101.60(4.000)
101.55(3.998) Dia.

Lock Nut
17(.67) Hex.

Fully Extended
279.5(11.00)
164.5
(6.48)
161.5
90
(6.36)
(3.54)
59(2.32)
135
(5.31)
9.5
77
(3.03)
(.37)
30(1.18)

86
(3.39)

Surface of
Suction Port

Surface of
Discharge Port

mm (IN.)

Model Numbers

View Arrow X

A37-F-R-02-S-K-A-3280

A37-F-R-02-S-K-D-3280
A37-F-R-02-S-K-R-3280

1. Install the pump so that the "Filling Port" is at the top.


2. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Model Numbers
A37-F-R-02-S-K--32

A37-F-R-02-S-K--3280

A37-F-R-02-S-K--3290

198 (7.80)

186 (7.32)

39 (1.54)

209 (8.23)

197 (7.76)

39 (1.54)

212 (8.35)

190.2 (7.49)

53 (2.09)

For other dimensions, refer to 32/3290 design.

"C" Thd.

"D" Thd.

"E" Thd.

Rc 1/2

G 1/2

Rc 1/4
1/4 BSP. Tr

1/2 BSP.F
1/2 NPT

1/2 NPT

1/4 NPT

"F" Thd.

"H" mm (IN.)

M10

19 (.75)

7/16-14 UNC

20 (.79)

DIMENSIONS IN MILLIMETRES (INCHES)


Axial Port Type

Foot Mounting Type

Port mounting dimensions are the same as those of pressure


compensator model. Refer to page 19 for port mounting dimensions.

Mounting bracket is common to that of pressure compensator model.


Refer to page 19 for the dimensions of mounting bracket.

No.31

"A" Series Piston Pumps


A56--R-02

PISTON
PUMPS

Installation Drawing
Side Port Type
Flange Mtg.: A56-F-R-02-S-K--32/3290
Fully Extended
292(11.50)
177
(6.97)
90
174
(3.54)
(6.85)
62(2.44)
147.5
(5.81)
50.5(1.99) 9.5(.37)

Filling Port 1
[22(.87) Hex. Head Plug Furnished]
Drain Port 2
"C" Thd. (Both Sides)

43.5(1.71)
"PP1"
"PP2"

35.32(1.391)
35.14(1.383)
101.60(4.000)
101.55(3.999) Dia.

R14(R.55)
120(4.72) Dia.

146
(5.75)
174
(6.85)
232
(9.13)

"F" Thd. "H" Deep


4 Places
3

Pilot Port "PP1"


"E" Thd.
Pressure Adj. Screw (PL)
14(.55) Hex.
Works at Solenoid
INC.
De-energised

26
13
(.51) (1.02)
6(.24)

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
170.5
(6.71)

190
(7.48)

Flow Adj. Screw


5(.20) Hex. Soc.

A56-F-R-02-S-K--3280

50
(1.97)

DEC.

77.1
(3.04)

100
(3.94)
Surface of
Suction Port

12
30.2
(1.189)
(.47)
207
(8.15)

31.75(1.2500)
31.70(1.2480) Dia.

Front Side : Discharge Port 30(1.18) Dia.


Rear Side : Suction Port 35(1.38) Dia.

Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
Works at Solenoid
Energised

49 4
(1.93)

14
(.55)

322.5
(12.70)
174
(6.85)
146
(5.75)
90
(3.54)
77
(3.03)
58.7(2.311)

41
7.97(.3138) (1.61)
7.94(.3126)

40
(1.57)

Electrical Conduit
Connection
"D" Thd. (Both Ends)

206
(8.11)
224.5
(8.84)

Lock Nut
14(.55) Hex.

Pilot Port "PP2"


"E" Thd.
74
(2.91)
6
50
(.24) (1.97)

25
(.98)

Lock Nut
17(.67) Hex.

100
(3.94)
Surface of
Discharge Port

View Arrow X
mm (IN.)

Model Numbers
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (3280 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

A56-F-R-02-S-K-A-3280

A56-F-R-02-S-K-D-3280
A56-F-R-02-S-K-R-3280

223 (8.78)

211 (8.31)

39 (1.54)

234 (9.21)

222 (8.74)

39 (1.54)

237 (9.33)

215.2 (8.47)

53 (2.09)

For other dimensions, refer to 32/3290 design.

4. Dimensions show surface of drain port.

Model Numbers
A56-F-R-02-S-K--32

A56-F-R-02-S-K--3280

A56-F-R-02-S-K--3290

"C" Thd.

"D" Thd.

Rc 3/4

G 1/2

Rc 1/4
1/4 BSP. Tr

3/4 BSP.F
3/4 NPT

"E" Thd.

1/2 NPT

1/4 NPT

"F" Thd.

"H" mm (IN.)

M10

19 (.75)

7/16-14 UNC

20 (.79)

DIMENSIONS IN MILLIMETRES (INCHES)


Axial Port Type

Foot Mounting Type

Port mounting dimensions are the same as those of pressure compensator


model. Refer to page 20 for port mounting dimensions.

Mounting bracket is common to that of pressure compensator model.


Refer to page 20 for the dimensions of mounting bracket.

No.32

"A" Series Piston Pumps


A70-FR02

PISTON
PUMPS

Installation Drawing
Flange Mtg. : A70-FR02S-60/6090

27(1.06) Dia.
Spotface
(From Rear)
4 Places

40
(1.57)

19.5
(.77)
16
(.63)
18
(.71)

26.2
(1.031)

"F" Thd.
17(.67) Deep
4 Places

31.75(1.250)
31.70(1.248) Dia.
35.32(1.391)
35.14(1.383)
127.00(5.000)
126.95(4.998) Dia.

52.4
(2.063)

90
(3.54)

7.97(.3138)
7.94(.3126)

202.5
(7.97)
186.5
(7.34)
18(.71)
14(.55)

9.5(.37)

Discharge Port
26(1.02) Thd.

95
95
(3.74) (3.74)
73
73
(2.87) (2.87)
10
(.39)

Surface of
Discharge Port
4
Surface of
Drain Port

35(1.38) Dia.
Spotface
(From Rear)
2 Places

114.4
(4.508)
134
(5.28)
181
(7.13)
211
(8.31)

246.5
(9.70)

INC.

Pilot port "PP1"


"E" Thd.
10
(.39)

3
1

Electrical Conduit
Connection
"D" Thd. (Both Ends)

Eye Bolt
M10

Filling Port
[22(.87) Hex. Head Plug Furnished]

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

Suction Port
38(1.50) Dia.
69.9
(2.752)

90
Pressure Adj. Screw (PH)
(3.54)
14(.55) Hex.
66
Works at Solenoid
(2.60)
Energised

118
(4.65)

Drain Port
"C" Thd. (Both Sides)
62(2.44)

Pilot Port 3
"PP2" "E" Thd.
Surface of
Suction Port
Surface of 4
Drain Port

218.5
(8.60)
237
(9.33)

114.4
(4.508)
180
(7.09)

Fully Extended
354.5(13.96)
239
(9.41)
90
236
(9.29)
(3.54)
209.5
(8.25)
65
(2.56)

Flow Adj. Screw


17(.67) Hex.
DEC.
5

Case Drain Port


5(.20) Hex. Soc.

View Arrow X

35.7
(1.406)
246.5
(9.70)

"H" Thd. "J" Deep


4 Places

View Arrow Y
Model Numbers

"C" Thd.

"D" Thd.

"E" Thd.

Rc 3/4

G 1/2

Rc 1/4

A70-FR02S-60

A70-FR02S-6080

1/4 BSP. Tr

3/4 BSP.F

A70-FR02S-6090

3/4 NPT

1/4 NPT

1/2 NPT

A70-FR02S-6080

"F" Thd.

"H" Thd.

"J" mm (IN.)

M10

M12

19 (.75)

7/16-14 UNC

1/2-13 UNC

21 (.83)

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (6080 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
232.5
93.1
(9.15)
(3.67)
d
66
(2.60)

4. Dimensions show surface of drain port.

5. Case drain port is available for use when draining hydraulic


fluid from pump casing.

DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A70-FR02SA-6080
A70-FR02SD-6080
A70-FR02SR-6080

mm (IN.)
a

236 (9.29)

224 (8.82)

39 (1.54)

247 (9.72)

235 (9.25)

39 (1.54)

250 (9.84)

228.2 (8.98)

53 (2.09)

Foot Mounting Type


Mounting bracket is common to that of pressure
compensator model. Refer to page 21 for the dimensions
of mounting bracket.

For other dimensions, refer to 60/6090 design.

No.33

"A" Series Piston Pumps


A90-FR02

PISTON
PUMPS

Installation Drawing
Flange Mtg.: A90-FR02S-60/6090
Surface of
Discharge Port

Drain Port
"C" Thd. (Both Sides)

Surface of
Drain Port

263.5
95
(10.37)
(3.74)
23(.91)
119.5
(4.70)
13(.51)

Pilot Port
"PP2" "E" Thd.

Surface of
Suction Port

105
105
(4.13) (4.13)
68 68
(2.68) (2.68)
2.5 53.5
(.1) (2.11)

Surface of
Drain Port

9.56(.3764)
9.53(.3752)

212
(8.35)
196
(7.72)

113
(4.45)
22
(.87)
23
(.91)

30.2
(1.189)
"F" Thd.
"J" Deep
4 Places

270
(10.63)

38.10(1.500)
38.05(1.498) Dia.
42.36(1.668)
42.18(1.661)
152.40(6.000)
152.35(5.998) Dia.

58.7
(2.311)
Discharge Port
32(1.26) Dia.

161.6
(6.362)
127
180
(7.09)
(5.00)
227
(8.94)
246.5
(9.70)

63(2.48)

21.5 (.85) Dia. Through


39(1.54) Dia. Spotface
(From Rear)
4 Places

R22(R.87)

161.6
(6.362)

Case drain Port


5(.20) Hex. Soc.

Pilot Port "PP1"


"E" Thd.

22.5
(.89)

Eye Bolt
M10
1

Filling Port
[27(1.06) Hex. Head Plug Furnished]

2.5
(.10)

Fully Extended
379(14.92)
260.5
90
(10.26)
(3.54)

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

Electrical Conduit Connection


"D" Thd. (Both Ends)

77.8
(3.063)
88
(3.46)
168
(6.61)
196
(7.72)

Pressure Adj. Screw (PH)


14(.55) Hex.
Works at Solenoid INC.
Energised

Flow Adj. Screw


17(.67) Hex. Soc.

Suction Port
48(1.89) Dia.

DEC.

View Arrow X

42.9
(1.689)
270
(10.63)

"H" Thd. "K" Deep


4 Places

View Arrow Y
Model Numbers

"C" Thd.

"D" Thd.

"E" Thd.

Rc 3/4

G 1/2

Rc 1/4

A90-FR02S-60

A90-FR02S-6080

A90-FR02S-6090

1/4 BSP. Tr

3/4 BSP.F
3/4 NPT

1/4 NPT

1/2 NPT

A90-FR02S-6080

"F" Thd.

"H" Thd.

"J" mm (IN.) "K" mm (IN.)

M10

M12

19 (.75)

19 (.75)

7/16-14 UNC

1/2-13 UNC

20 (.79)

21 (.83)

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (6080 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
56.6(2.23)
257.5
(10.14)
53.5
d
(2.11)

4. Dimensions show surface of drain port.

5. Case drain port is available for use when draining hydraulic fluid from pump casing.

DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A90-02FRSA-6080
A90-02FRSD-6080
A90-02FRSR-6080

mm (IN.)
a

245 (9.65)

233 (9.17)

39 (1.54)

256 (10.08)

244 (9.61)

39 (1.54)

259 (10.20)

237.2 (9.34)

53 (2.09)

For other dimensions, refer to 60/6090 design.

No.34

Foot Mounting Type


Mounting bracket is common to that of pressure
compensator model. Refer to page 22 for the dimensions
of mounting bracket.

"A" Series Piston Pumps


A145-FR02

PISTON
PUMPS

Installation Drawing
Flange Mtg. : A145-FR02S-60/6090
Surface of
Discharge Port

112
(4.41)
23(.91)

89
(3.50)

Surface of
Drain Port

13(.51)

Drain Port "C" Thd.


(Both Sides)

Pilot Port
"PP2" "E" Thd.

Surface of
Drain Port
11.14(.4386)
11.11(.4374)

21.5(.85) Dia. Through


39(1.54) Dia. Spotface
(From Rear)
4 Places

299.5
(11.79)

Eye Bolt
M10
3

198
(7.80)
248.5
(9.78)
228.6
(9.000)

110
(4.33)

Case Drain Port


5(.20) Hex. Soc.

24
(.94)
26
(1.02)

R22(R .87)

228.6
(9.000)
273
(10.75)

281.5
(11.08)

Y
141
(5.55)

44.45(1.750)
44.40(1.748) Dia.
49.39(1.944)
49.21(1.937)
152.40(6.000)
152.35(5.998) Dia.

58.7
(2.311)
Discharge Port
32(1.26) Dia.
30.2
(1.189)

Surface of
Suction Port

70(2.76)

"F" Thd.
"J" Deep
4 Places

112
112
(4.41) (4.41)
72 72
(2.83) (2.83)
12
(.47)

214
(8.43)

Fully Extended
400.5(15.77)
285
(11.22)
255.5
(10.06)

Electrical Conduit
Connection
"D" Thd. (Both Ends)
90
(3.54)

Pressure Adj. Screw (PH)


Pilot Port "PP1"
Filling Port
68
14(.55) Hex.
[27(1.06) Hex. Head Plug Furnished]
"E" Thd.
(2.68)
Works at Solenoid
INC.
Energised
12
(.47)
Pressure Adj. Screw (PL)
14(.55) Hex.
Works at Solenoid INC.
De-energised

77.8
(3.063)

Suction Port
48(1.89) Thd.

230
(9.06)

Flow Adj. Screw


17(.67) Hex. Soc.

"H" Thd. "K" Deep


4 Places

DEC.

42.9
(1.689)
299.5
(11.79)

View Arrow X

View Arrow Y
Model Numbers
A145-FR02S-60

A145-FR02S-6080

A145-FR02S-6090

"C" Thd.

"D" Thd.

Rc 3/4

G 1/2

"E" Thd.
Rc 1/4
1/4 BSP. Tr

3/4 BSP.F
3/4 NPT

1/4 NPT

1/2 NPT

A145-FR02S-6080

92(3.62)

"J" mm (IN.) "K" mm (IN.)

M10

M12

19 (.75)

19 (.75)

7/16-14 UNC

1/2-13 UNC

20 (.79)

21 (.83)

4. Dimensions show surface of drain port.

68
(2.68)

5. Case drain port is available for use when draining hydraulic


fluid from pump casing.
b

"H" Thd.

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (6080 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
278
(10.94)

"F" Thd.

DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A145-FR02SA-6080
A145-FR02SD-6080
A145-FR02SR-6080

mm (IN.)
a

247 (9.72)

235 (9.25)

39 (1.54)

258 (10.16)

246 (9.69)

39 (1.54)

261 (10.28)

239.2 (9.42)

53 (2.09)

Foot Mounting Type


Mounting bracket is common to that of pressure
compensator model. Refer to page 23 for the dimensions
of mounting bracket.

For other dimensions, refer to 60/6090 design.

No.35

"A" Series Piston Pumps


Variable Displacement-Single Pumps
Pressure Compensator with Unloading Type
A16 / A22 / A37 / A56 / A70 / A90 / A145

PISTON
PUMPS

Specifications

Performance Characteristics

Output Flow

Graphic Symbol

SOL
"OFF"

SOL
"ON"

M
O

Pressure

Specifications
Shaft Speed
Range
r/min

Model Numbers

Geometric
Displacement
cm3/rev
(cu. in. /rev)

Minimum
Adj. Flow
cm3/rev
(cu. in. /rev)

Rated

Intermittent

Max.

Min.

A16--R-03--K--32

15.8
(.964)

4
(.244)

16
(2320)

21
(3050)

1.2
(170)

1800

600

A22--R-03--K--32

22.2
(1.355)

6
(.366)

16
(2320)

16
(2320)

1.2
(170)

1800

600

A37--R-03--K--32

36.9
(2.25)

10
(.61)

16
(2320)

21
(3050)

1.2
(170)

1800

600

A56--R-03--K--32

56.2
(3.43)

12
(.73)

16
(2320)

21
(3050)

1.2
(170)

1800

600

A70-R03S-K-60

70.0
(4.27)

30
(1.83)

25
(3630)

25
(3630)

1.2
(170)

1800

600

A90-R03S-K-60

91.0
(5.55)

56
(3.42)

25
(3630)

25
(3630)

1.2
(170)

1800

600

A145-R03S-K-60

145
(8.85)

83
(5.06)

25
(3630)

25
(3630)

1.2
(170)

1800

600

Consult YUKEN for details.

No.36

Operating Pres.
MPa (PSI)

Unloading Pres.
MPa (PSI)

"A" Series Piston Pumps


Variable Displacement-Single Pumps

PISTON
PUMPS

Proportional Electro-Hydraulic Load-Sensing Type


A16 / A22 / A37 / A56 / A70 / A90 / A145
Model Number Designation
Graphic Symbols
i1

i2

i2

A16/A22/A37
i1

i2

M
O

Output Flow

i1

Input
(Small Current
i Large)

Performance Characteristics

(Small

M
O

Pressure
Input
Large)
Current i 1

A70/A90/A145
M
O

A56

Model Number Designation

A56
Series Number

-F

-R

Mounting

Direction of
Rotation

A16
(15.8 cm3/rev)

-04

-C

-K

-32

Control Type

Pres. Adj. Range


MPa (PSI)

Shaft
Extension

Design
Number

Design Std.

B: 1.5 - 7 (220 - 1020)


C: 1.5 - 16 (220 - 2320)
H: 1.5 - 21 (220 - 3050)

Viewed from
Shaft End

A22
(22.2 cm3/rev)

F:
Flange Mtg.

A37
(36.9 cm3/rev)

L:
Foot Mtg.

R:
Clockwise

04:
Proportional
Electro-Hydraulic
Load Sensing

A56
(56.2 cm3/rev)

A70
Series Number
A70
(70.0 cm3/rev)
A90
(91.0 cm3/rev)
A145
(145 cm3/rev)

-F

Mounting

Direction of
Rotation

F:
Flange Mtg.
L:
Foot Mtg.

B: 1.5 - 7 (220 - 1020)


C: 1.5 - 16 (220 - 2320)

32

32
K:
Keyed Shaft

Control Type

Pres. Adj. Range


MPa (PSI)

32

-60

Port Position

Design
Number

Design Std.

Viewed from
Shaft End

R:
Clockwise

32

B: 2 - 7 (290 - 1020)
C: 2 - 16 (290 - 2320)
H: 2 - 21 (290 - 3050)

04

Refer to

60
04:
Proportional
Electro-Hydraulic
Load Sensing

1. Available to supply pump with anti-clockwise rotation. Consult


Yuken for details.

C: 1.5 - 16 (220 - 2320)


H: 1.5 - 21 (220 - 3050)

S:
Side Port

60

Refer to

60
2. Design Standards: None ........... Japanese Standard "JIS"
80 ............... European Design Standard
90 ............... N. American Design Standard

No.37

"A" Series Piston Pumps


Proportional Electro-Hydraulic Load-Sensing Type
A16 / A22 / A37 / A56 / A70 / A90 / A145

PISTON
PUMPS

Pipe Flange Kits / Instructions


Pipe Flange Kits
Pipe flange kits are available.
When ordering, specify the kit nuneber from the table below.
Pipe Flange Kit Numbers
Pump Model
Numbers

Name of
Port

A16--R-04
A22--R-04

Suction

A37--R-04
A56--R-04
A70-R04
A90-R04
A145-R04

Discharge

Threaded Connection
Japanese
Standard
"JIS"

European
Design
Standard

F5-06-A-10
2

Socket Welding

Butt Welding

Japanese Standard N. American Japanese Standard N. American


"JIS" &
"JIS" &
Design
Design
European Design
European Design
Standard
Standard
Standard
Standard

N. American
Design
Standard

F5-06-A-1080 F5-06-A-1090
2

F5-06-B-10

F5-06-B-1090

F5-06-C-10
2

F5-06-C-1090
2

Suction

F5-10-A-10

F5-10-A-1080 F5-10-A-1090

F5-10-B-10

F5-10-B-1090

F5-10-C-10

F5-10-C-1090

Discharge

F5-06-A-10

F5-06-A-1080 F5-06-A-1090

F5-06-B-10

F5-06-B-1090

F5-06-C-10

F5-06-C-1090

Suction

F5-12-A-10

F5-12-A-1080 F5-12-A-1090

F5-12-B-10

F5-12-B-1090

F5-12-C-10

F5-12-C-1090

Discharge

F5-10-A-10

F5-10-A-1080 F5-10-A-1090

F5-10-B-10

F5-10-B-1090

F5-10-C-10

F5-10-C-1090

Suction

F5-16-A-10

F5-16-A-1080 F5-16-A-1090

F5-16-B-10

F5-16-B-1090

F5-16-C-10

F5-16-C-1090

Discharge

F5-10-A-10

F5-10-A-1080 F5-10-A-1090

F5-10-B-10

F5-10-B-1090

F5-10-C-10

F5-10-C-1090

1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength
of the flanges. Therefore, please pay cautious attension to the operating pressure when the socket welding flanges are used.
2. Discharge port for pump model "A16" and "A22" is available only the threaded connections.
Detail of the pipe flange kits are given in the Catalogue No. Pub. EC-3001.

Instructions
Bleeding Air
In order to get steadily controlled pressure and flow, bleed air by loosening the air vent screw and fill solenoid armature
with operating oil.
Manual Adjustment Screws
Manual adjustment screws may be used for initial running adjustment or in case of electrical failures in order to adjust pressure and
flow temporarily. In case of normal use, put the manual adjustment screws back in their preset positions.

Position of Cable Departure


Position of cable departure can be changed. For details, refer to EDG-01 valve Catalogue No. Pub. EC-1302.

Connection of Surge Cut-off Valve to "A" Series Pump (For A16 to A56 Type)
If using surge cut-off valve (SF1105-A-10), connect between pilot port "PP" of this pump and port "PP" of surge cut-off valve as
pilot piping (refer to drawing below).
Inside diameter of pipe should be more than 8 mm(.32 in.).
Consult Yuken of detail of surge cut-off valve.

Surge Cut-off Valve


(SF1105-A-10)

i1

"PP"
i2

M
O

No.38

"A" Series Piston Pumps

PISTON
PUMPS

Proportional Electro-Hydraulic Load-Sensing Type


A16 / A22 / A37 / A56 / A70 / A90 / A145
Specifications

Model No.

A16

A22

A37

A56

A70

A90

A145

15.8
(.964)

22.2
(1.355)

36.9
(2.25)

56.2
(3.43)

70.0
(4.27)

91.0
(5.55)

145
(8.85)

16
(2320)

16
(2320)

16
(2320)

16
(2320)

21
(3050)

21
(3050)

21
(3050)

21
(3050)

16
(2320)

21
(3050)

21
(3050)

21
(3050)

21
(3050)

21
(3050)

Max.

1800

1800

1800

1800

1800

1800

1800

Min.

600

600

600

600

600

600

600

L /min
(U.S. GPM)

1 - 28.4
(.26 - 7.5)

1 - 40
(.26 - 10.6)

1 - 66
(.26 - 17.4)

1 - 101
(.26 - 26.7)

1 - 126
(.26 - 33.3)

1 - 163
(.26 - 43.1)

2 - 261
(.53 - 69.0)

Min Pres. Required


for Flow Adj.

MPa
(PSI)

1.5
(220)

1.5
(220)

1.5
(220)

2.0
(290)

1.0
(145)

1.0
(145)

1.0
(145)

Differential Pres.
(Discharge Pres.
-Load Pres.)

MPa
(PSI)

Step Response 5
(0 Max. Flow)

ms

Descriptions

Geometric
Displacement

cm /rev
(cu. in./rev)
Rated

Operating Pres.
MPa (PSI)
Intermittent
Shaft Speed Range
r/min
Flow Adj.
Range

Flow
Control

0.22
(30)

0.37
(55)
70

80

120

125

Hysteresis

Pres.
Control

Less than 3%

Rated Current

mA

Coil Resistance
[20C (68F)]

Pres. Adj. Range


Step
Response
ms
Hysteresis

MPa (PSI)

740

210

820

920

920

790
10

Refer to Model Number Designation

80

80

50

55

150

150

160

t2

140

90

80

80

80

120

180

C: 860
H: 765

C: 873
H: 765

C: 875
H: 755

Less than 2%
mA

Coil Resistance
[20C (68F)]

Approx. Mass
kg
(lbs.)

700

120

t1

Rated Current

Applicable Amplifier Model

900

100

(Pres. Adj. Range)


B: 770, C:880, H:790

10
AME-D2-1010--10

Flange Mtg.

32
(70.6)

32
(70.6)

38
(83.8)

45
(99.2)

72.5
(160)

88.5
(195)

109.5
(241)

Foot Mtg.

34.2
(75.4)

34.2
(75.4)

43.2
(95.3)

49.3
(109)

84.5
(186)

109
(240)

134.5
(297)

1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.
Pres. Step Response

2. When operating the pump exceeding the rated pressure, operating


conditions are restricted. Refer to page 6 for the details.

Model

3. For detail specifications of power amplifiers, refer to Catalogue No.


Pub. EC-1305.

A16, A22

1.5 16 MPa
16 1.5 MPa High Pressure Hose
(220 2320 PSI) (2320 220 PSI) 3/8" 2 m (6.6 ft)

4. The figure mentioned in the above table are those obtained using
Yuken's amplifier.

A37, A56

2.0 16 MPa
16 2.0 MPa High Pressure Hose
(290 2320 PSI) (2320 290 PSI) 3/4" 2 m (6.6 ft)

A70, A90
A145

3.0 16 MPa
16 3.0 MPa High Pressure Hose
(435 2320 PSI) (2320 435 PSI) 1-1/4" 2 m (6.6 ft)

5. Step response depends on circuit and operating conditions. Data


shown in the table above is an example based on the condition right.

t1

t2

Loading Volume

No.39

"A" Series Piston Pumps

PISTON
PUMPS

Proportional Electro-Hydraulic Load-Sensing Type


A16 / A22 / A37 / A56 / A70 / A90 / A145
Typical Pump Characteristics

Typical Performance Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50C (122F)]

Full Cut-off Pres. vs. Input Current


A16/A22/A37/A56

2500

MPa
21
20

"H"

16

2000
1500
1000
500
0

Full Cut-off Pressure

Full Cut-off Pressure

PSI
3000

A70/A90/A145

"C"

12
8

"B"

PSI
3500

MPa
24

3000

20

2500

12

200

400

600

"C"

1500
1000
500

0
0

"H"

16

2000

800 900

8
4
0
0

200

Input Current mA

400

600

800

1000

Input Current mA

Note: Pressure adjustment range "H" is not available for A22.

A22

Output Flow vs. Input Current

U.S.GPM L /min
11
40
10

A16
U.S.GPM L /min
32
8
24

16

Output Flow

Output Flow

N=1800 r/min

2
0

10
0
0

200

400

600

800

U.S.GPM
30

1000

Output Flow

25

N=1800 r/min

400

L /min
110
100

20

80

15

60

10

40

20
0
0

60

600

200

400

600

800 900

Input Current mA

12

A70

10

40

30

U.S.GPM

20

35
30

L /min
140
120

20

80

10

40

Output Flow

10
0
0

200

400

600

800

Input Current mA

0
0

N=1800 r/min

200

400

600

800

1000

Input Current mA

A90
U.S.GPM L /min
200
50

N=1800 r/min

A145
U.S.GPM
75
70

30

120

60

20

80

10

40

Output Flow

160

40

0
0

200

400

600

Input Current mA

800

1000

50
40

L /min
280

N=1800 r/min

240
200
160

30

120

20

80

10

40

0
0

200

400

600

Input Current mA

No.40

800

N=1800 r/min

50

Output Flow

200

A56

U.S.GPM L /min
70
18

Output Flow

20

Input Current mA

A37

14

30

Input Current mA

16

N=1800 r/min

800

1000

"A" Series Piston Pumps


A16 / A22-F-R-04

PISTON
PUMPS

Installation Drawing
Flange Mtg : A16-F-R-04--K-32/3280/3290
A22-F-R-04--K-32/3280/3290
44.5(1.75)
229
(9.02)
6.5(.26)
213
(8.39)
Filling Port
167.5
[22(.87) Hex. Head Plug Furnished]
(6.59)
59(2.32)
Drain Port
"C" Thd.
26.5(1.04)

Cable Departure
(For Pres. Control)

101.5
(4.00)
63.2
(2.49)

Manual Pressure Adj. Screw


3(.12) Hex. Soc.
INC.
57.5
(2.26)
103
(4.06)

41
(1.61)

Air Vent 3(.12) Hex.


3 Places.

22.2(.874)
32.5
(1.28)
94
(3.70)

18
(.71)

Pilot Port "PP"


"D" Thd.
2
Cable Departure
(For Flow Control)

152.2
(5.99)
70
(2.76)

47.6
(1.874)

48
(1.89)

106
(4.17)
130
(5.12)

Suction Port 19(.75) Dia.

"H" Thd. 17(.67) Deep


4 Places
See

R12
(R.47)

95(3.74) Dia.

188
(7.40)

Tank Port
"F" Thd.
Air Vent
3 (.12) Hex. Soc.
Manual Pressure Adj. Screw
3 (.12) Hex. Soc.
INC.
Safety Valve Pressure Adj. Screw
17(.67) Hex. Soc.
INC.

12
(.47)

96
(3.78)

4.79(.1886)
4.76(.1874)

19.05(.7500)
19.02(.7488) Dia.
21.24(.836)
21.08(.830)
82.55(3.250)
82.50(3.248) Dia.

12
(.47)
172
(6.77)
Surface of Suction Port
187
(7.36)
262
(10.31)
Surface of Discharge Port

Pressure Gauge Connection


for Pump Discharge Pressure
"D" Thd

56
(2.20)
85
(3.35)

Discharge Port
"E" Thd.
190.5
(7.50)

View Arrow X
Model Numbers
A16/A22-F-R-04--K-32
A16/A22-F-R-04--K3280
1. Detail of Discharge Ports
[For Japanese Standard]

1
(.04)

14
(.55)
2.5
(.10)

"C" Thd.

"D" Thd.

"E" Thd.
1

"F" Thd.

Rc 3/8

Rc 1/4

G 3/8

3/8 BSP.F

1/4 BSP.Tr

3/8 BSP.F

1/4 BSP.F

3/8 NPT

1/4 NPT

3/8 NPT

1/4 NPT

Rc 1/4

"H" Thd.
M10
3/8-16 UNC

2. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
3. Do not touch the screw because it is adjusted at the time of shipment.

18.6(.73) Dia. 15

G 3/8 Thd.
28(1.10) Dia.

255.5
(10.06)
177.5
(6.99)
152.5
(6.00)
57.5
(2.26)

25(.98)

DIMENSIONS IN
MILLIMETRES (INCHES)

Foot Mounting Type


Mounting bracket is common to that of pressure compensator model.
Refer to page 18 for the dimensions of mounting bracket.

No.41

"A" Series Piston Pumps


A37-F-R-04

PISTON
PUMPS

Installation Drawing
Flange Mtg. : A37-F-R-04--K-32/3280/3290

308.5
(12.15)
296.5
(11.67)

Air Vent 3(.12) Hex.


3 Places.
Manual Flow Adj. Screw
3(.12) Hex. Soc.
INC.

59
(2.32)
9.5
(.37)

Manual Pressure Adj. Screw


3(.12) Hex. Soc.
INC.
Air Vent 3(.12) Hex.
3 Places.
Cable Departure 1
(For Pres. Control)

110.5
(4.35)
77
(3.03)

Filling Port
[22(.87) Hex. Head Plug Furnished]

77.3
(3.04)

30(1.18)

Pressure Gauge
Connection for Pump
Discharge Pressure
"D" Thd

100.5
(3.96)
27
(1.06)

Suction Port
32(1.26) Dia.
"E" Thd. "H" Deep
4 Places

132
(5.20)

25
(.98)
R14
(R .55)

120(4.72) Dia.
146
(5.75)
174
(6.85)
202
(7.95)

115.5
(4.55)

1. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)

Cable Departure 1
(For Flow Control)

47.6
(1.874)

85
(3.35)
58.7
(2.311)

Pilot Port "PP"


"D" Thd.

195
(7.68)
Surface of Suction Port
228
(8.98)
282
(11.10)
Surface of Discharge Port

22.23(.8752)
22.20(.8740) Dia.
25.01(.985)
24.85(.978)
101.60(4.000)
101.55(3.998) Dia.

12
(.47)

105
(4.13)

32(1.26)

7
(.28)

14
(.55)

275.5
(10.85)
185.5
(7.30)
147.2
(5.80)

Drain Port
"C" Thd.

Safety Valve
Pressure Adj. Screw
3(.12) Hex. Soc.
INC.
6.38(.2512)
6.35(.2500)

22.2
(.874)

30.2
(1.189)

Discharge Port
20(.79) Thd.
"F" Thd. 19(.75) Deep
4 Places

36 42
(1.42) (1.65)
83
(3.27)

View Arrow X

A37-F-R-04--K-3280

A37-F-R-04--K-3290

"D" Thd.

Rc 1/2

Rc 1/4

1/2 BSP.F

1/4 BSP.Tr

1/2 NPT

1/4 NPT

60 74
(2.362) (2.91)
39
115
(4.53)
(1.54)

"E" Thd.

"F" Thd.

"H" mm (IN.)

M10

M10

19 (.75)

7/16-14 UNC

3/8-16 UNC

20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

14(.55) Dia. Through


28(1.10) Dia. Spotface
4 Places

3
(.12)

Foot Mtg. : A37-L-R-04--K-32/3280/3290

"C" Thd.

14
(.55)
15
(.59)
102
(4.02)

Model Numbers
A37-F-R-04--K-32

120
(4.72)
95
95
(3.740) (3.740)
230
(9.06)

For other dimensions, refer to "Flange Mtg.".

No.42

"A" Series Piston Pumps


A56-F-R-04

PISTON
PUMPS

Installation Drawing
Flange Mtg. : A56-F-R-04--K-32/3280/3290
Air Vent 3(.12) Hex.
3 Places.

9.5
(.37)

240
(9.45)
Surface of Suction Port
240
(9.45)
294
(11.57)
Surface of Discharge Port
100
(3.94)
27
(1.06)

Pilot Port "PP"


"D" Thd.

116
(4.57)

31.75(1.250)
31.70(1.248) Dia.
35.32(1.931)
35.14(1.383)
101.60(4.000)
101.55(3.998) Dia.

77.8
(3.06)
Surface of Drain Port
41 49
(1.61) (1.93)

Safety Valve
Pressure Adj. Screw
3(.12) Hex. Soc.
INC.
7.97(.3138)
7.94(.3126)
25
(.98)

14
(.55)

90
(3.54)

283.5
(11.16)
185.5
(7.30)
147.2
(5.80)
7
(.28)

12
(.47)

Pressure Gauge Connection


for Pump Discharge Pressure
"D" Thd

Manual Pressure Adj. Screw


3(.12) Hex. Soc.
INC.
Air Vent
3(.12) Hex.
3 Places.

122.5
Cable Departure 1
(4.82)
(For Pres. Control)
50.5
(1.95)
Filling Port
43.5
[22(.87) Hex. Head Plug Furnished]
(1.71) 40
(1.57)
2
Drain Port (Both Sides)
"C" Thd.

Manual Flow Adj. Screw


3(.12) Hex. Soc.
INC.

120(4.72) Dia.

R14
(R.55)

146
(5.75)
174
(6.85)
232
(9.13)

Cable Departure 1
(For Flow Control)

1. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
47.6
(1.874)

94
(3.70)
58.7
(2.311)
Suction Port
35(1.38) Dia.
30.2
(1.189)

View Arrow X

22.2
(.874)

Discharge Port
20(.79) Thd.
"F" Thd. "H" Deep
4 Places

38 44
(1.50) (1.73)
85
(3.35)

Model Numbers
A56-F-R-04--K-32

A56-F-R-04--K-3280

A56-F-R-04--K-3290

60 77
(2.362)(3.03)
42
115
(4.53)
(1.65)

"D" Thd.

Rc 3/4

Rc 1/4

3/4 BSP.F

1/4 BSP.Tr

3/4 NPT

1/4 NPT

14(.55) Dia. Through


28(1.10) Dia. Spotface
4 Places

Foot Mtg. : A56-L-R-04--K-32/3280/3290

"C" Thd.

"E" Thd.

"F" Thd.

"H" mm (IN.)

M10

M10

19 (.75)

7/16-14 UNC

3/8-16 UNC

20 (.79)

DIMENSIONS IN
MILLIMETRES (INCHES)

14
(.55)
15
(.59)
102
(4.02)

"E" Thd. "H" Deep


4 Places

2. Use either port of two pilot and drain ports at your option. Keep the
remaining port plugged. Note that on the European Design Standard
(3280 Design), only the left side, as viewed from the shaft end, of the
drain port is machined.

(.12)

62
(2.44)

320.5
(12.62)
308.5
(12.15)

120
(4.72)
95
95
(3.740) (3.740)
230
(9.06)

For other dimensions, refer to "Flange Mtg.".

No.43