Beruflich Dokumente
Kultur Dokumente
A10-FR01
PISTON
PUMPS
CAUTION
A10-FR01-12/1280/1290
37 41
64 39 23 37 36 35 38
25
23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
24
6
5
34 33 32 31 30 29 28 27 26 1
51 52 53 54 55 56 57 58 59 60 61
63
62
Section X-X
List of Seals & Bearings
Qty.
Item
Name of Parts
Part Numbers
C&H
Oil Seal
TCN24408Y
O-Ring
SO-NA-G50
Bearing
6204
16
O-Ring
SO-NB-P14
20
O-Ring
SO-NB-G120
23
O-Ring
SO-NB-P6
33
Bearing
HMK1215
37
O-Ring
SO-NB-P12
54
O-Ring
SO-NA-A018
62
O-Ring
SO-NB-P10
64
O-Ring
SO-NB-P9
When ordering seals, please specify the seal kit number from the table below.
A10-FR01B-12/1280/1290
KS-A10-01B-12
A10-FR01C-12/1280/1290
A10-FR01H-12/1280/1290
No.24
KS-A10-01H-12
PISTON
PUMPS
35
43
44
25 11
56
60 31
52
22
32
27
61
58
29
57
51
5
55
54
49
53
38 43
37
15 18
24
12 34
39
16
41
36
28
50
42
30
19 33 20
17
10 21
47
46
CAUTION
23
45
14
13
Section X-X
List of Seal and Bearings
Part Numbers
Item
Name of Parts
A56--R-01
Qty.
27
Bearing
28
Bearing
6307
NUP 207E
HMK 2025V2
HMK 2530V2
29
Oil Seal
TCN 355511
TCN 355511
30
35
1303-PK211969-1
1316-PK211970-9
1307-PK211971-7
SO-NA-G25
SO-NB-G30
SO-NA-P36
36
O-Ring
SO-NB-P12
37
O-Ring
SO-NB-P9
38
O-Ring
SO-NA-A017
39
Seal Washer
W8
60
O-Ring
SO-NB-P14
61
O-Ring
A16--R-01
A22--R-01
A37--R-01
Z30-1303-PK410300-8
TCN 254511
Gasket
O-Ring
6305
HMK 1715
SO-NB-P10A
SO-NA-G55
1
SO-NA-G75
When ordering seals, please specify the seal kit number from the table below.
A16--R-01--K--32
KS-A16-01-32
A37--R-01--K--32
KS-A37-01-32
A22--R-01--K--32
A56--R-01--K--32
KS-A56-01-32
No.25
PISTON
PUMPS
CAUTION
A70/A90-R01S-60/6080/6090
27
53
26
55
37
12
32
56
36
67
4
51
46
35
42
P
Q
45
60
64
62
34
54
40
47
38
48
52
66
39
23
24
58
19
44
43
11
21
20
25
61
33
31
13
18
28
59
10
54
50
44
68
16
22
15 14
44
Detail "A"
69
17
29
65
30
70
Section Z-Z
Section X-X
(Only for "A70")
Section X-X
List of Seals and Bearings
Part Numbers
Item
Name of Parts
A70-R01S
A90-R01S
Qty.
Gasket
1314E-PK211972-5
1310E-PK211973-3
22
Back Up Ring
1310E-PK412440-0
1310E-PK412440-0
38
Bearing
NUP 208EX50
NUP 210E
39
Needle Bearing
HMK 3030V2
HMK 3530BV2
40
Oil Seal
TCN 355511
TCN 456812
42
O-Ring
SO-FA-G85
SO-FA-G95
43
O-Ring
SO-NA-P18
SO-NA-P18
44
O-Ring
SO-NB-P9
SO-NB-P9
67
O-Ring
SO-NB-P14
SO-NB-P18
68
Seal Washer
W10
70
O-Ring
1
SO-NB-P5
A70-R01S-60
KS-A70-01-60
A90-R01S-60
No.26
KS-A90-01-60
When ordering the seals, please specify the seal kit number
from the table left.
PISTON
PUMPS
CAUTION
A145-R01S-60/6080/6090
58 69 51 52 36 65 62 46 65 14 8
25
X
7 33 16 3 60 37 73 59 5
61
9
59
44
67
54
70
41
35
68
27
29
64
74
39
30
57
40
28
53 2 34 26 11 6
1 32 38 10 13 12 16 71 31 72
26 27 28 29 30 31 32 33 34
24
62
56
19
17
50
48
66
23
57
63 15 46
20
21 45
43
18
22
59
47
49
Detail "A"
Section X-X
Name of Parts
Part Numbers
Qty.
Gasket
1312-PK211974-1
15
Back Up Ring
1310E-PK412440-0
39
Bearing
NUP 2211ET2
40
Needle Bearing
8Q-NK385530
41
Oil Seal
TCN 507212
43
O-Ring
44
O-Ring
SO-FA-G105
45
O-Ring
SO-NA-P18
46
O-Ring
SO-NB-P9
47
O-Ring
SO-NB-A017
48
O-Ring
SO-NB-A016
49
Back Up Ring
For SO-NB-A017
50
Back Up Ring
For SO-NB-A016
73
O-Ring
SO-NB-P18
No.27
PISTON
PUMPS
Specifications
Graphic Symbol
PH
Output Flow
PL
Performance Characteristics
M
O
SOL
"OFF"
SOL
"ON"
PL
Pressure
PH
Specifications
Model Numbers
A16--R-02--K-32
A22--R-02--K-32
A37--R-02--K-32
A56--R-02--K-32
A70-R02S-60
A90-R02S-60
A145-R02S-60
Operating Pres.
MPa (PSI)
Geometric
Displacement
cm3/rev
(cu. in. /rev)
Minimum
Adj. Flow
cm3/rev
(cu. in. /rev)
Rated
Minimum
Adj. Pres.
1
Intermittent MPa (PSI)
50
A120
AC
A200
A240
D12
DC
D24
(K Series)
D48
ACDC R100
Rectified R200
60
50
60
50
60
50
60
50 /60
Flange
Mtg.
Foot
Mtg.
4 (.244)
16 (2320)
21 (3050)
1.2 (170)
1800
600
6 (.366)
16 (2320)
16 (2320)
1.2 (170)
1800
600
36.9 (2.25)
10 (.61)
16 (2320)
21 (3050)
1.2 (170)
1800
600
56.2 (3.43)
12 (.73)
16 (2320)
21 (3050)
1.2 (170)
1800
600
70.0 (4.27)
30 (1.83)
25 (3630)
25 (3630)
2 (290)
1800
600
91.0 (5.55)
56 (3.42)
25 (3630)
25 (3630)
2 (290)
1800
600
145 (8.85)
83 (5.06)
25 (3630)
25 (3630)
2 (290)
1800
600
Voltage (V)
Current & Power at Rated Voltage
Source Serviceable Inrush
Holding
Power
Rating
Range
(A)
(A)
(W)
80 -110
0.51
2.42
100
0.37
2.14
100
90 -120
0.44
2.35
110
96 -132
0.42
2.02
120
108 -144
0.31
1.78
160 -220
0.25
1.21
200
0.19
1.07
200
180 - 240
0.22
1.18
220
192 - 264
0.21
1.01
240
216 - 288
0.15
0.89
10.8 - 13.2
2.45
12
21.6 - 26.4
1.23
24
29
43.2 - 52.8
0.61
48
90 - 110
0.33
100
29
180 - 220
0.16
200
Inrush current in the above table shows rms values at maximum stroke.
No.28
Min.
15.8 (.964)
Solenoid Ratings
A100
Max.
Approx. Mass
kg (lbs.)
22.2 (1.355)
1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.
PISTON
PUMPS
A16
Series
Number
-F
-R
-02
-S
-K
-A100
-32
Mounting
Direction of
Rotation
Control
Type
Port
Position
Shaft
Extension
Coil Type of
Solenoid Valve
Design
Number
Design
Std.
A16
(15.8 cm3/rev)
A22
(22.2 cm3/rev)
A37
(36.9 cm3/rev)
F:
Flange
Mtg.
L:
Foot
Mtg.
Viewed from
Shaft End
R:
Clockwise
(Normal)
32
02:
Solenoid Two
Prsuure Control
Type
None:
Axial Port
S:
Side Port
A56
(56.2 cm3/rev)
A70
Series
Number
A70
(70 cm3/rev)
A90
(91.0 cm3/rev)
A145
(145 cm3/rev)
AC
A100,A120
A200,A240
DC
K:
Keyed Shaft D12,D24
D48
(ACDC Rectified)
R100,R200
32
Refer to
32
32
-F
02
A100
-60
Mounting
Direction of
Rotation
Control
Type
Port
Position
Coil Type of
Solenoid Valve
Design
Number
Design
Std.
F:
Flange Mtg.
L:
Foot Mtg.
Viewed from
Shaft End
R:
Clockwise
(Normal)
02:
Solenoid Two
Prsuure Control
Type
AC
A100,A120
A200,A240
S:
Side Port
DC
D12,D24
D48
(ACDC Rectified)
R100,R200
60
60
Refer to
60
Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 10 to 16.
No.29
PISTON
PUMPS
Installation Drawing
Axial Port Type
Flange Mtg.: A16-F-R-02-K--32/3290
A22-F-R-02-K--32/3290
172
(6.77)
Pilot Port "PP1"
"E" Thd.
23
(.91)
106
(4.17)
130
(5.12)
188
(7.40)
3(.12)
R14(R.55)
95(3.74) Dia.
A16-F-R-02-K--3280
A22-F-R-02-K--3280
Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 in.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
135
80.1
(5.31)
(3.15)
d
53
(2.09)
161
(6.34)
Suction Port
19(.75) Dia.
22.2(.874)
65
(2.56)
47.6
(1.874)
DEC.
View Arrow X
Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
Works at Solenoid
Energised
177
(6.97)
195.5
(7.70)
12
(.47)
12
(.47)
Lock Nut
17(.67) Hex.
16
(.63)
18(.71)
96
(3.78)
19.05(.7500)
19.02(.7488) Dia.
21.24(.836)
21.08(.830)
82.55(3.250)
82.50(3.248) Dia.
273.5
(10.77)
145
(5.71)
117
(4.61)
62
(2.44)
Lock Nut
14(.55) Hex.
Fully Extended
2
256.5(10.10)
Pilot Port "PP2"
141.5
"E" Thd.
(5.37)
90
138.5
77
(3.54)
(5.45)
(3.03)
44.5(1.75)
Electrical Conduit
112
3
53
Connection
(4.41)
(.12) (2.09)
"D" Thd. (Both Ends)
59
6.5
(2.32) (.26)
1
Filling Port
26.5
[22(.87) Hex. Head Plug Furnished]
"PP1"
(1.04)
Drain Port
"PP2"
"C" Thd.
4.79(.1886)
25
4.76(.1874)
(.98)
mm (IN.)
Model Numbers
A16/A22-F-R-02-K-A-
194 (7.64)
182. (7.17)
39 (1.54)
3280
205 (8.07)
193 (7.60)
39 (1.54)
A16/A22-F-R-02-K-D-
208 (8.19)
186.2 (7.33)
53 (2.09)
Model Numbers
A16/A22-F-R-02-K--32
A16/A22-F-R-02-K--3280
A16/A22-F-R-02-K--3290
"C" Thd.
"D" Thd.
Rc 3/8
G 1/2
Rc 1/4
1/4 BSP. Tr
3/8 BSP.F
3/8 NPT
"E" Thd.
1/2 NPT
1/4 NPT
"F" Thd.
M10
3/8-16 UNC
No.30
PISTON
PUMPS
Installation Drawing
Side Port Type
Flange Mtg. : A37-F-R-02-S-K-32/3290
32(1.26)
14
(.55)
30.2
12
(1.189) (.47)
178.5
(7.03)
R14(R.55)
120(4.72) Dia.
146.5
(5.75)
174
(6.85)
202
(7.95)
A37-F-R-02-S-K-3280
Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
77.1
158
(3.04)
(6.22)
d
50
(1.97)
165
(6.50)
b
86
(3.39)
DEC.
6.38(.2512)
6.35(.2500)
105
(4.13)
26
13
(.51) (1.02)
Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
6(.24)
Works at Solenoid
Energised
Electrical Conduit
Connection
"D" Thd. (Both Ends)
Drain Port
"C" Thd.
22.23(.8752)
22.20(.8740) Dia.
25.01(.985)
24.85(.978)
289.5
(11.40)
149
(5.87)
121
(4.76)
68
(2.68)
58.7
(2.311)
"PP2"
Filling Port
[22(.87) Hex. Head Plug Furnished]
(2.91)
6
50
(.24) (1.97)
181
(7.13)
199.5
(7.85)
"PP1"
25
(.98)
Lock Nut
14(.55) Hex.
101.60(4.000)
101.55(3.998) Dia.
Lock Nut
17(.67) Hex.
Fully Extended
279.5(11.00)
164.5
(6.48)
161.5
90
(6.36)
(3.54)
59(2.32)
135
(5.31)
9.5
77
(3.03)
(.37)
30(1.18)
86
(3.39)
Surface of
Suction Port
Surface of
Discharge Port
mm (IN.)
Model Numbers
View Arrow X
A37-F-R-02-S-K-A-3280
A37-F-R-02-S-K-D-3280
A37-F-R-02-S-K-R-3280
Model Numbers
A37-F-R-02-S-K--32
A37-F-R-02-S-K--3280
A37-F-R-02-S-K--3290
198 (7.80)
186 (7.32)
39 (1.54)
209 (8.23)
197 (7.76)
39 (1.54)
212 (8.35)
190.2 (7.49)
53 (2.09)
"C" Thd.
"D" Thd.
"E" Thd.
Rc 1/2
G 1/2
Rc 1/4
1/4 BSP. Tr
1/2 BSP.F
1/2 NPT
1/2 NPT
1/4 NPT
"F" Thd.
"H" mm (IN.)
M10
19 (.75)
7/16-14 UNC
20 (.79)
No.31
PISTON
PUMPS
Installation Drawing
Side Port Type
Flange Mtg.: A56-F-R-02-S-K--32/3290
Fully Extended
292(11.50)
177
(6.97)
90
174
(3.54)
(6.85)
62(2.44)
147.5
(5.81)
50.5(1.99) 9.5(.37)
Filling Port 1
[22(.87) Hex. Head Plug Furnished]
Drain Port 2
"C" Thd. (Both Sides)
43.5(1.71)
"PP1"
"PP2"
35.32(1.391)
35.14(1.383)
101.60(4.000)
101.55(3.999) Dia.
R14(R.55)
120(4.72) Dia.
146
(5.75)
174
(6.85)
232
(9.13)
26
13
(.51) (1.02)
6(.24)
Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
170.5
(6.71)
190
(7.48)
A56-F-R-02-S-K--3280
50
(1.97)
DEC.
77.1
(3.04)
100
(3.94)
Surface of
Suction Port
12
30.2
(1.189)
(.47)
207
(8.15)
31.75(1.2500)
31.70(1.2480) Dia.
Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
Works at Solenoid
Energised
49 4
(1.93)
14
(.55)
322.5
(12.70)
174
(6.85)
146
(5.75)
90
(3.54)
77
(3.03)
58.7(2.311)
41
7.97(.3138) (1.61)
7.94(.3126)
40
(1.57)
Electrical Conduit
Connection
"D" Thd. (Both Ends)
206
(8.11)
224.5
(8.84)
Lock Nut
14(.55) Hex.
25
(.98)
Lock Nut
17(.67) Hex.
100
(3.94)
Surface of
Discharge Port
View Arrow X
mm (IN.)
Model Numbers
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (3280 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.
A56-F-R-02-S-K-A-3280
A56-F-R-02-S-K-D-3280
A56-F-R-02-S-K-R-3280
223 (8.78)
211 (8.31)
39 (1.54)
234 (9.21)
222 (8.74)
39 (1.54)
237 (9.33)
215.2 (8.47)
53 (2.09)
Model Numbers
A56-F-R-02-S-K--32
A56-F-R-02-S-K--3280
A56-F-R-02-S-K--3290
"C" Thd.
"D" Thd.
Rc 3/4
G 1/2
Rc 1/4
1/4 BSP. Tr
3/4 BSP.F
3/4 NPT
"E" Thd.
1/2 NPT
1/4 NPT
"F" Thd.
"H" mm (IN.)
M10
19 (.75)
7/16-14 UNC
20 (.79)
No.32
PISTON
PUMPS
Installation Drawing
Flange Mtg. : A70-FR02S-60/6090
27(1.06) Dia.
Spotface
(From Rear)
4 Places
40
(1.57)
19.5
(.77)
16
(.63)
18
(.71)
26.2
(1.031)
"F" Thd.
17(.67) Deep
4 Places
31.75(1.250)
31.70(1.248) Dia.
35.32(1.391)
35.14(1.383)
127.00(5.000)
126.95(4.998) Dia.
52.4
(2.063)
90
(3.54)
7.97(.3138)
7.94(.3126)
202.5
(7.97)
186.5
(7.34)
18(.71)
14(.55)
9.5(.37)
Discharge Port
26(1.02) Thd.
95
95
(3.74) (3.74)
73
73
(2.87) (2.87)
10
(.39)
Surface of
Discharge Port
4
Surface of
Drain Port
35(1.38) Dia.
Spotface
(From Rear)
2 Places
114.4
(4.508)
134
(5.28)
181
(7.13)
211
(8.31)
246.5
(9.70)
INC.
3
1
Electrical Conduit
Connection
"D" Thd. (Both Ends)
Eye Bolt
M10
Filling Port
[22(.87) Hex. Head Plug Furnished]
Suction Port
38(1.50) Dia.
69.9
(2.752)
90
Pressure Adj. Screw (PH)
(3.54)
14(.55) Hex.
66
Works at Solenoid
(2.60)
Energised
118
(4.65)
Drain Port
"C" Thd. (Both Sides)
62(2.44)
Pilot Port 3
"PP2" "E" Thd.
Surface of
Suction Port
Surface of 4
Drain Port
218.5
(8.60)
237
(9.33)
114.4
(4.508)
180
(7.09)
Fully Extended
354.5(13.96)
239
(9.41)
90
236
(9.29)
(3.54)
209.5
(8.25)
65
(2.56)
View Arrow X
35.7
(1.406)
246.5
(9.70)
View Arrow Y
Model Numbers
"C" Thd.
"D" Thd.
"E" Thd.
Rc 3/4
G 1/2
Rc 1/4
A70-FR02S-60
A70-FR02S-6080
1/4 BSP. Tr
3/4 BSP.F
A70-FR02S-6090
3/4 NPT
1/4 NPT
1/2 NPT
A70-FR02S-6080
"F" Thd.
"H" Thd.
"J" mm (IN.)
M10
M12
19 (.75)
7/16-14 UNC
1/2-13 UNC
21 (.83)
Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
232.5
93.1
(9.15)
(3.67)
d
66
(2.60)
DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A70-FR02SA-6080
A70-FR02SD-6080
A70-FR02SR-6080
mm (IN.)
a
236 (9.29)
224 (8.82)
39 (1.54)
247 (9.72)
235 (9.25)
39 (1.54)
250 (9.84)
228.2 (8.98)
53 (2.09)
No.33
PISTON
PUMPS
Installation Drawing
Flange Mtg.: A90-FR02S-60/6090
Surface of
Discharge Port
Drain Port
"C" Thd. (Both Sides)
Surface of
Drain Port
263.5
95
(10.37)
(3.74)
23(.91)
119.5
(4.70)
13(.51)
Pilot Port
"PP2" "E" Thd.
Surface of
Suction Port
105
105
(4.13) (4.13)
68 68
(2.68) (2.68)
2.5 53.5
(.1) (2.11)
Surface of
Drain Port
9.56(.3764)
9.53(.3752)
212
(8.35)
196
(7.72)
113
(4.45)
22
(.87)
23
(.91)
30.2
(1.189)
"F" Thd.
"J" Deep
4 Places
270
(10.63)
38.10(1.500)
38.05(1.498) Dia.
42.36(1.668)
42.18(1.661)
152.40(6.000)
152.35(5.998) Dia.
58.7
(2.311)
Discharge Port
32(1.26) Dia.
161.6
(6.362)
127
180
(7.09)
(5.00)
227
(8.94)
246.5
(9.70)
63(2.48)
R22(R.87)
161.6
(6.362)
22.5
(.89)
Eye Bolt
M10
1
Filling Port
[27(1.06) Hex. Head Plug Furnished]
2.5
(.10)
Fully Extended
379(14.92)
260.5
90
(10.26)
(3.54)
77.8
(3.063)
88
(3.46)
168
(6.61)
196
(7.72)
Suction Port
48(1.89) Dia.
DEC.
View Arrow X
42.9
(1.689)
270
(10.63)
View Arrow Y
Model Numbers
"C" Thd.
"D" Thd.
"E" Thd.
Rc 3/4
G 1/2
Rc 1/4
A90-FR02S-60
A90-FR02S-6080
A90-FR02S-6090
1/4 BSP. Tr
3/4 BSP.F
3/4 NPT
1/4 NPT
1/2 NPT
A90-FR02S-6080
"F" Thd.
"H" Thd.
M10
M12
19 (.75)
19 (.75)
7/16-14 UNC
1/2-13 UNC
20 (.79)
21 (.83)
Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
56.6(2.23)
257.5
(10.14)
53.5
d
(2.11)
5. Case drain port is available for use when draining hydraulic fluid from pump casing.
DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A90-02FRSA-6080
A90-02FRSD-6080
A90-02FRSR-6080
mm (IN.)
a
245 (9.65)
233 (9.17)
39 (1.54)
256 (10.08)
244 (9.61)
39 (1.54)
259 (10.20)
237.2 (9.34)
53 (2.09)
No.34
PISTON
PUMPS
Installation Drawing
Flange Mtg. : A145-FR02S-60/6090
Surface of
Discharge Port
112
(4.41)
23(.91)
89
(3.50)
Surface of
Drain Port
13(.51)
Pilot Port
"PP2" "E" Thd.
Surface of
Drain Port
11.14(.4386)
11.11(.4374)
299.5
(11.79)
Eye Bolt
M10
3
198
(7.80)
248.5
(9.78)
228.6
(9.000)
110
(4.33)
24
(.94)
26
(1.02)
R22(R .87)
228.6
(9.000)
273
(10.75)
281.5
(11.08)
Y
141
(5.55)
44.45(1.750)
44.40(1.748) Dia.
49.39(1.944)
49.21(1.937)
152.40(6.000)
152.35(5.998) Dia.
58.7
(2.311)
Discharge Port
32(1.26) Dia.
30.2
(1.189)
Surface of
Suction Port
70(2.76)
"F" Thd.
"J" Deep
4 Places
112
112
(4.41) (4.41)
72 72
(2.83) (2.83)
12
(.47)
214
(8.43)
Fully Extended
400.5(15.77)
285
(11.22)
255.5
(10.06)
Electrical Conduit
Connection
"D" Thd. (Both Ends)
90
(3.54)
77.8
(3.063)
Suction Port
48(1.89) Thd.
230
(9.06)
DEC.
42.9
(1.689)
299.5
(11.79)
View Arrow X
View Arrow Y
Model Numbers
A145-FR02S-60
A145-FR02S-6080
A145-FR02S-6090
"C" Thd.
"D" Thd.
Rc 3/4
G 1/2
"E" Thd.
Rc 1/4
1/4 BSP. Tr
3/4 BSP.F
3/4 NPT
1/4 NPT
1/2 NPT
A145-FR02S-6080
92(3.62)
M10
M12
19 (.75)
19 (.75)
7/16-14 UNC
1/2-13 UNC
20 (.79)
21 (.83)
68
(2.68)
"H" Thd.
Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
278
(10.94)
"F" Thd.
DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A145-FR02SA-6080
A145-FR02SD-6080
A145-FR02SR-6080
mm (IN.)
a
247 (9.72)
235 (9.25)
39 (1.54)
258 (10.16)
246 (9.69)
39 (1.54)
261 (10.28)
239.2 (9.42)
53 (2.09)
No.35
PISTON
PUMPS
Specifications
Performance Characteristics
Output Flow
Graphic Symbol
SOL
"OFF"
SOL
"ON"
M
O
Pressure
Specifications
Shaft Speed
Range
r/min
Model Numbers
Geometric
Displacement
cm3/rev
(cu. in. /rev)
Minimum
Adj. Flow
cm3/rev
(cu. in. /rev)
Rated
Intermittent
Max.
Min.
A16--R-03--K--32
15.8
(.964)
4
(.244)
16
(2320)
21
(3050)
1.2
(170)
1800
600
A22--R-03--K--32
22.2
(1.355)
6
(.366)
16
(2320)
16
(2320)
1.2
(170)
1800
600
A37--R-03--K--32
36.9
(2.25)
10
(.61)
16
(2320)
21
(3050)
1.2
(170)
1800
600
A56--R-03--K--32
56.2
(3.43)
12
(.73)
16
(2320)
21
(3050)
1.2
(170)
1800
600
A70-R03S-K-60
70.0
(4.27)
30
(1.83)
25
(3630)
25
(3630)
1.2
(170)
1800
600
A90-R03S-K-60
91.0
(5.55)
56
(3.42)
25
(3630)
25
(3630)
1.2
(170)
1800
600
A145-R03S-K-60
145
(8.85)
83
(5.06)
25
(3630)
25
(3630)
1.2
(170)
1800
600
No.36
Operating Pres.
MPa (PSI)
Unloading Pres.
MPa (PSI)
PISTON
PUMPS
i2
i2
A16/A22/A37
i1
i2
M
O
Output Flow
i1
Input
(Small Current
i Large)
Performance Characteristics
(Small
M
O
Pressure
Input
Large)
Current i 1
A70/A90/A145
M
O
A56
A56
Series Number
-F
-R
Mounting
Direction of
Rotation
A16
(15.8 cm3/rev)
-04
-C
-K
-32
Control Type
Shaft
Extension
Design
Number
Design Std.
Viewed from
Shaft End
A22
(22.2 cm3/rev)
F:
Flange Mtg.
A37
(36.9 cm3/rev)
L:
Foot Mtg.
R:
Clockwise
04:
Proportional
Electro-Hydraulic
Load Sensing
A56
(56.2 cm3/rev)
A70
Series Number
A70
(70.0 cm3/rev)
A90
(91.0 cm3/rev)
A145
(145 cm3/rev)
-F
Mounting
Direction of
Rotation
F:
Flange Mtg.
L:
Foot Mtg.
32
32
K:
Keyed Shaft
Control Type
32
-60
Port Position
Design
Number
Design Std.
Viewed from
Shaft End
R:
Clockwise
32
B: 2 - 7 (290 - 1020)
C: 2 - 16 (290 - 2320)
H: 2 - 21 (290 - 3050)
04
Refer to
60
04:
Proportional
Electro-Hydraulic
Load Sensing
S:
Side Port
60
Refer to
60
2. Design Standards: None ........... Japanese Standard "JIS"
80 ............... European Design Standard
90 ............... N. American Design Standard
No.37
PISTON
PUMPS
Name of
Port
A16--R-04
A22--R-04
Suction
A37--R-04
A56--R-04
A70-R04
A90-R04
A145-R04
Discharge
Threaded Connection
Japanese
Standard
"JIS"
European
Design
Standard
F5-06-A-10
2
Socket Welding
Butt Welding
N. American
Design
Standard
F5-06-A-1080 F5-06-A-1090
2
F5-06-B-10
F5-06-B-1090
F5-06-C-10
2
F5-06-C-1090
2
Suction
F5-10-A-10
F5-10-A-1080 F5-10-A-1090
F5-10-B-10
F5-10-B-1090
F5-10-C-10
F5-10-C-1090
Discharge
F5-06-A-10
F5-06-A-1080 F5-06-A-1090
F5-06-B-10
F5-06-B-1090
F5-06-C-10
F5-06-C-1090
Suction
F5-12-A-10
F5-12-A-1080 F5-12-A-1090
F5-12-B-10
F5-12-B-1090
F5-12-C-10
F5-12-C-1090
Discharge
F5-10-A-10
F5-10-A-1080 F5-10-A-1090
F5-10-B-10
F5-10-B-1090
F5-10-C-10
F5-10-C-1090
Suction
F5-16-A-10
F5-16-A-1080 F5-16-A-1090
F5-16-B-10
F5-16-B-1090
F5-16-C-10
F5-16-C-1090
Discharge
F5-10-A-10
F5-10-A-1080 F5-10-A-1090
F5-10-B-10
F5-10-B-1090
F5-10-C-10
F5-10-C-1090
1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength
of the flanges. Therefore, please pay cautious attension to the operating pressure when the socket welding flanges are used.
2. Discharge port for pump model "A16" and "A22" is available only the threaded connections.
Detail of the pipe flange kits are given in the Catalogue No. Pub. EC-3001.
Instructions
Bleeding Air
In order to get steadily controlled pressure and flow, bleed air by loosening the air vent screw and fill solenoid armature
with operating oil.
Manual Adjustment Screws
Manual adjustment screws may be used for initial running adjustment or in case of electrical failures in order to adjust pressure and
flow temporarily. In case of normal use, put the manual adjustment screws back in their preset positions.
Connection of Surge Cut-off Valve to "A" Series Pump (For A16 to A56 Type)
If using surge cut-off valve (SF1105-A-10), connect between pilot port "PP" of this pump and port "PP" of surge cut-off valve as
pilot piping (refer to drawing below).
Inside diameter of pipe should be more than 8 mm(.32 in.).
Consult Yuken of detail of surge cut-off valve.
i1
"PP"
i2
M
O
No.38
PISTON
PUMPS
Model No.
A16
A22
A37
A56
A70
A90
A145
15.8
(.964)
22.2
(1.355)
36.9
(2.25)
56.2
(3.43)
70.0
(4.27)
91.0
(5.55)
145
(8.85)
16
(2320)
16
(2320)
16
(2320)
16
(2320)
21
(3050)
21
(3050)
21
(3050)
21
(3050)
16
(2320)
21
(3050)
21
(3050)
21
(3050)
21
(3050)
21
(3050)
Max.
1800
1800
1800
1800
1800
1800
1800
Min.
600
600
600
600
600
600
600
L /min
(U.S. GPM)
1 - 28.4
(.26 - 7.5)
1 - 40
(.26 - 10.6)
1 - 66
(.26 - 17.4)
1 - 101
(.26 - 26.7)
1 - 126
(.26 - 33.3)
1 - 163
(.26 - 43.1)
2 - 261
(.53 - 69.0)
MPa
(PSI)
1.5
(220)
1.5
(220)
1.5
(220)
2.0
(290)
1.0
(145)
1.0
(145)
1.0
(145)
Differential Pres.
(Discharge Pres.
-Load Pres.)
MPa
(PSI)
Step Response 5
(0 Max. Flow)
ms
Descriptions
Geometric
Displacement
cm /rev
(cu. in./rev)
Rated
Operating Pres.
MPa (PSI)
Intermittent
Shaft Speed Range
r/min
Flow Adj.
Range
Flow
Control
0.22
(30)
0.37
(55)
70
80
120
125
Hysteresis
Pres.
Control
Less than 3%
Rated Current
mA
Coil Resistance
[20C (68F)]
MPa (PSI)
740
210
820
920
920
790
10
80
80
50
55
150
150
160
t2
140
90
80
80
80
120
180
C: 860
H: 765
C: 873
H: 765
C: 875
H: 755
Less than 2%
mA
Coil Resistance
[20C (68F)]
Approx. Mass
kg
(lbs.)
700
120
t1
Rated Current
900
100
10
AME-D2-1010--10
Flange Mtg.
32
(70.6)
32
(70.6)
38
(83.8)
45
(99.2)
72.5
(160)
88.5
(195)
109.5
(241)
Foot Mtg.
34.2
(75.4)
34.2
(75.4)
43.2
(95.3)
49.3
(109)
84.5
(186)
109
(240)
134.5
(297)
1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.
Pres. Step Response
Model
A16, A22
1.5 16 MPa
16 1.5 MPa High Pressure Hose
(220 2320 PSI) (2320 220 PSI) 3/8" 2 m (6.6 ft)
4. The figure mentioned in the above table are those obtained using
Yuken's amplifier.
A37, A56
2.0 16 MPa
16 2.0 MPa High Pressure Hose
(290 2320 PSI) (2320 290 PSI) 3/4" 2 m (6.6 ft)
A70, A90
A145
3.0 16 MPa
16 3.0 MPa High Pressure Hose
(435 2320 PSI) (2320 435 PSI) 1-1/4" 2 m (6.6 ft)
t1
t2
Loading Volume
No.39
PISTON
PUMPS
Typical Performance Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50C (122F)]
2500
MPa
21
20
"H"
16
2000
1500
1000
500
0
PSI
3000
A70/A90/A145
"C"
12
8
"B"
PSI
3500
MPa
24
3000
20
2500
12
200
400
600
"C"
1500
1000
500
0
0
"H"
16
2000
800 900
8
4
0
0
200
Input Current mA
400
600
800
1000
Input Current mA
A22
U.S.GPM L /min
11
40
10
A16
U.S.GPM L /min
32
8
24
16
Output Flow
Output Flow
N=1800 r/min
2
0
10
0
0
200
400
600
800
U.S.GPM
30
1000
Output Flow
25
N=1800 r/min
400
L /min
110
100
20
80
15
60
10
40
20
0
0
60
600
200
400
600
800 900
Input Current mA
12
A70
10
40
30
U.S.GPM
20
35
30
L /min
140
120
20
80
10
40
Output Flow
10
0
0
200
400
600
800
Input Current mA
0
0
N=1800 r/min
200
400
600
800
1000
Input Current mA
A90
U.S.GPM L /min
200
50
N=1800 r/min
A145
U.S.GPM
75
70
30
120
60
20
80
10
40
Output Flow
160
40
0
0
200
400
600
Input Current mA
800
1000
50
40
L /min
280
N=1800 r/min
240
200
160
30
120
20
80
10
40
0
0
200
400
600
Input Current mA
No.40
800
N=1800 r/min
50
Output Flow
200
A56
U.S.GPM L /min
70
18
Output Flow
20
Input Current mA
A37
14
30
Input Current mA
16
N=1800 r/min
800
1000
PISTON
PUMPS
Installation Drawing
Flange Mtg : A16-F-R-04--K-32/3280/3290
A22-F-R-04--K-32/3280/3290
44.5(1.75)
229
(9.02)
6.5(.26)
213
(8.39)
Filling Port
167.5
[22(.87) Hex. Head Plug Furnished]
(6.59)
59(2.32)
Drain Port
"C" Thd.
26.5(1.04)
Cable Departure
(For Pres. Control)
101.5
(4.00)
63.2
(2.49)
41
(1.61)
22.2(.874)
32.5
(1.28)
94
(3.70)
18
(.71)
152.2
(5.99)
70
(2.76)
47.6
(1.874)
48
(1.89)
106
(4.17)
130
(5.12)
R12
(R.47)
95(3.74) Dia.
188
(7.40)
Tank Port
"F" Thd.
Air Vent
3 (.12) Hex. Soc.
Manual Pressure Adj. Screw
3 (.12) Hex. Soc.
INC.
Safety Valve Pressure Adj. Screw
17(.67) Hex. Soc.
INC.
12
(.47)
96
(3.78)
4.79(.1886)
4.76(.1874)
19.05(.7500)
19.02(.7488) Dia.
21.24(.836)
21.08(.830)
82.55(3.250)
82.50(3.248) Dia.
12
(.47)
172
(6.77)
Surface of Suction Port
187
(7.36)
262
(10.31)
Surface of Discharge Port
56
(2.20)
85
(3.35)
Discharge Port
"E" Thd.
190.5
(7.50)
View Arrow X
Model Numbers
A16/A22-F-R-04--K-32
A16/A22-F-R-04--K3280
1. Detail of Discharge Ports
[For Japanese Standard]
1
(.04)
14
(.55)
2.5
(.10)
"C" Thd.
"D" Thd.
"E" Thd.
1
"F" Thd.
Rc 3/8
Rc 1/4
G 3/8
3/8 BSP.F
1/4 BSP.Tr
3/8 BSP.F
1/4 BSP.F
3/8 NPT
1/4 NPT
3/8 NPT
1/4 NPT
Rc 1/4
"H" Thd.
M10
3/8-16 UNC
2. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
3. Do not touch the screw because it is adjusted at the time of shipment.
18.6(.73) Dia. 15
G 3/8 Thd.
28(1.10) Dia.
255.5
(10.06)
177.5
(6.99)
152.5
(6.00)
57.5
(2.26)
25(.98)
DIMENSIONS IN
MILLIMETRES (INCHES)
No.41
PISTON
PUMPS
Installation Drawing
Flange Mtg. : A37-F-R-04--K-32/3280/3290
308.5
(12.15)
296.5
(11.67)
59
(2.32)
9.5
(.37)
110.5
(4.35)
77
(3.03)
Filling Port
[22(.87) Hex. Head Plug Furnished]
77.3
(3.04)
30(1.18)
Pressure Gauge
Connection for Pump
Discharge Pressure
"D" Thd
100.5
(3.96)
27
(1.06)
Suction Port
32(1.26) Dia.
"E" Thd. "H" Deep
4 Places
132
(5.20)
25
(.98)
R14
(R .55)
120(4.72) Dia.
146
(5.75)
174
(6.85)
202
(7.95)
115.5
(4.55)
1. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
Cable Departure 1
(For Flow Control)
47.6
(1.874)
85
(3.35)
58.7
(2.311)
195
(7.68)
Surface of Suction Port
228
(8.98)
282
(11.10)
Surface of Discharge Port
22.23(.8752)
22.20(.8740) Dia.
25.01(.985)
24.85(.978)
101.60(4.000)
101.55(3.998) Dia.
12
(.47)
105
(4.13)
32(1.26)
7
(.28)
14
(.55)
275.5
(10.85)
185.5
(7.30)
147.2
(5.80)
Drain Port
"C" Thd.
Safety Valve
Pressure Adj. Screw
3(.12) Hex. Soc.
INC.
6.38(.2512)
6.35(.2500)
22.2
(.874)
30.2
(1.189)
Discharge Port
20(.79) Thd.
"F" Thd. 19(.75) Deep
4 Places
36 42
(1.42) (1.65)
83
(3.27)
View Arrow X
A37-F-R-04--K-3280
A37-F-R-04--K-3290
"D" Thd.
Rc 1/2
Rc 1/4
1/2 BSP.F
1/4 BSP.Tr
1/2 NPT
1/4 NPT
60 74
(2.362) (2.91)
39
115
(4.53)
(1.54)
"E" Thd.
"F" Thd.
"H" mm (IN.)
M10
M10
19 (.75)
7/16-14 UNC
3/8-16 UNC
20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
3
(.12)
"C" Thd.
14
(.55)
15
(.59)
102
(4.02)
Model Numbers
A37-F-R-04--K-32
120
(4.72)
95
95
(3.740) (3.740)
230
(9.06)
No.42
PISTON
PUMPS
Installation Drawing
Flange Mtg. : A56-F-R-04--K-32/3280/3290
Air Vent 3(.12) Hex.
3 Places.
9.5
(.37)
240
(9.45)
Surface of Suction Port
240
(9.45)
294
(11.57)
Surface of Discharge Port
100
(3.94)
27
(1.06)
116
(4.57)
31.75(1.250)
31.70(1.248) Dia.
35.32(1.931)
35.14(1.383)
101.60(4.000)
101.55(3.998) Dia.
77.8
(3.06)
Surface of Drain Port
41 49
(1.61) (1.93)
Safety Valve
Pressure Adj. Screw
3(.12) Hex. Soc.
INC.
7.97(.3138)
7.94(.3126)
25
(.98)
14
(.55)
90
(3.54)
283.5
(11.16)
185.5
(7.30)
147.2
(5.80)
7
(.28)
12
(.47)
122.5
Cable Departure 1
(4.82)
(For Pres. Control)
50.5
(1.95)
Filling Port
43.5
[22(.87) Hex. Head Plug Furnished]
(1.71) 40
(1.57)
2
Drain Port (Both Sides)
"C" Thd.
120(4.72) Dia.
R14
(R.55)
146
(5.75)
174
(6.85)
232
(9.13)
Cable Departure 1
(For Flow Control)
1. Cable Applicable:
Outside Dia......8-10 mm (.31-.39 IN.)
Conductor Area......Not Exceeding 1.5 mm2 (.002 Sq. IN.)
47.6
(1.874)
94
(3.70)
58.7
(2.311)
Suction Port
35(1.38) Dia.
30.2
(1.189)
View Arrow X
22.2
(.874)
Discharge Port
20(.79) Thd.
"F" Thd. "H" Deep
4 Places
38 44
(1.50) (1.73)
85
(3.35)
Model Numbers
A56-F-R-04--K-32
A56-F-R-04--K-3280
A56-F-R-04--K-3290
60 77
(2.362)(3.03)
42
115
(4.53)
(1.65)
"D" Thd.
Rc 3/4
Rc 1/4
3/4 BSP.F
1/4 BSP.Tr
3/4 NPT
1/4 NPT
"C" Thd.
"E" Thd.
"F" Thd.
"H" mm (IN.)
M10
M10
19 (.75)
7/16-14 UNC
3/8-16 UNC
20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
14
(.55)
15
(.59)
102
(4.02)
2. Use either port of two pilot and drain ports at your option. Keep the
remaining port plugged. Note that on the European Design Standard
(3280 Design), only the left side, as viewed from the shaft end, of the
drain port is machined.
(.12)
62
(2.44)
320.5
(12.62)
308.5
(12.15)
120
(4.72)
95
95
(3.740) (3.740)
230
(9.06)
No.43