Beruflich Dokumente
Kultur Dokumente
VS.RAB.NormRel.AMR
VS.RAB.AbnormRel.AMR
Main counter
VS.RAB.AbnormRel.CS.RF
Other reason
Sub counter
VS.RAB.AbnormRel.CS.RF.SRBReset
VS.RAB.AbnormRel.CS.RF.ULSync
VS.RAB.AbnormRel.CS.RF.UuNoReply
VS.RAB.AbnormRel.CS.OM
VS.RAB.AbnormRel.CS.Preempt
VS.RAB.AbnormRel.CS.UTRANgen
VS.RAB.AbnormRel.CS.IuAAL2
VS.RAB.AbnormRel.CS.OLC
Main counter
VS.RAB.AbnormRel.PS.RF
Other reason
2015-3-8
Sub-counter
VS.RAB.AbnormRel.PS.RF.SRBReset
VS.RAB.AbnormRel.PS.RF.ULSync
VS.RAB.AbnormRel.PS.RF.UuNoReply
VS.RAB.AbnormRel.PS.RF.TRBReset
VS.RAB.AbnormRel.PS.GTPULoss
VS.RAB.AbnormRel.PS.OM
VS.RAB.AbnormRel.PS.Preempt
VS.RAB.AbnormRel.PS.OLC
1 , 3
2. Common Reason
Call drop for abnormal reasons
Failure reason
VS.RAB.AbnormRel.CS.OM
VS.RAB.AbnormRel.CS.Preempt
VS.RAB.AbnormRel.CS.UTRANgen
VS.RAB.AbnormRel.CS.IuAAL2
VS.RAB.AbnormRel.CS.OLC
VS.RAB.AbnormRel.PS.GTPULoss
Common reason
Caused by some risk operation
Check whether congestion
Check alarms
Check IUCS transmission configuration and
alarm.
Check RTWP / congestions
Check IUPS transmission alarms
For RF reasons:
VS.RAB.AbnormRel.CS.RF.SRBRes
VS.RAB.AbnormRel.CS.RF.ULSync
VS.RAB.AbnormRel.CS.RF.UuNoRe
et
ply
Optimization SOP for RF reason call drops
1. check alarms
2. Using Nastar to check missing neighbors/ pilot pollution
3. Using the Naster to check the coverage of the cells.
How to solve the call drops if the cell located in weak coverage area/network edge?
1. Identify whether RF tuning is required or not (if some area a lot sites around but still
coverage not good then RF tuning is required)
2. Modify the handover threshold/cell reselection parameters, let UE come to 2G quickly
when 3G coverage become bad.
3. If UL limited, change the CPICH power or down tilt.
2 , 3
2015-3-8
3 , 3