Beruflich Dokumente
Kultur Dokumente
, LTD
2N6027
SCR
PROGRAMMABLE
UNIJUNCTION TRANSISTOR
DESCRIPTION
FEATURES
SYMBOL
ORDERING INFORMATION
Ordering Number
Lead Free
2N6027L-T92-B
2N6027L-T92-K
Note: Pin Assignment: A: Anode
Halogen Free
2N6027G-AB3-R
2N6027G-T92-B
2N6027G-T92-K
G: Gate
K: Cathode
Package
SOT-89
TO-92
TO-92
Pin Assignment
1
2
3
A
G
K
A
G
K
A
G
K
Packing
Tape Reel
Tape Box
Bulk
MARKING
SOT-89
www.unisonic.com.tw
Copyright 2015 Unisonic Technologies Co., Ltd
TO-92
1 of 4
QW-R301-022.D
2N6027
SCR
PARAMETER
SYMBOL
RATINGS
UNIT
Gate to Cathode Forward Voltage
VGKF
40
V
Gate to Cathode Reverse Voltage
VGKR
-5.0
V
Gate to Anode Reverse Voltage
VGAR
40
V
TJ=25C
150
mA
DC Forward Anode Current
IT
Derate Above 25C
2.67
mA/C
DC Gate Current
IG
50
mA
1.0
A
Pulse Width=100s
Repetitive Peak Forward
ITRM
Current (Note 2)
Pulse Width=20 s
2.0
A
NonRepetitive Peak Forward Current 10 s Pulse Width
ITSM
5.0
A
Anode to Cathode Voltage
VAK
40
V
SOT-89
280
Power Dissipation
PD
mW
TO-92
300
4.45
SOT-89
Power Dissipation Derate
mW/C
1/JA
Above 25C
TO-92
4.0
Operating Junction Temperature Range
TJ
50 ~ +100
C
Storage Temperature Range
TSTG
55 ~ +150
C
Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2. Duty Cycle 1%
3. Anode positive, RGA=1000 ohms
Anode negative, RGA=Open
THERMAL CHARACTERISTICS
PARAMETER
Junction to Ambient
Junction to Case
SYMBOL
SOT-89
TO-92
SOT-89
TO-92
JA
JC
RATINGS
220
200
80
75
UNIT
C/W
C/W
SYMBOL
Peak Current
IP
Offset Voltage
VT
Valley Current
IV
TEST CONDITIONS
VS=10V, RG=1M
VS=10V, RG=10k
VS=10V, RG=1M
VS=10V, RG=1M
VS=10V, RG=10k
VS=10V, RG=200
VS=40V, TA=25C, Cathode Open
VS=40V, TA=75C, Cathode Open)
MIN
0.2
70
1.5
60
TYP
1.25
4.0
0.70
18
150
MAX
2.0
5.0
1.6
50
1.0
3.0
10
5.0
50
nA
0.8
11
40
1.5
V
V
ns
80
UNIT
A
A
V
A
A
mA
nA
nA
2 of 4
QW-R301-022.D
2N6027
SCR
3 of 4
QW-R301-022.D
2N6027
SCR
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
4 of 4
QW-R301-022.D