Liquid

SMALL SIZE STRAINERS

GENERAL SPECIFICATION

GS.No.GCB001E8

Nominal size : 10, 20mm

GENERAL

To prevent potential damage to the flowmeter with foreign


solids suspended in the fluid being metered, it is usually
necessary to provide a strainer immediately upstream of the
meter.
A range of standardized strainers designed for small size
meter are available for individual applications.

FEATURES

1. Simple design and easy to service


2. Small pressure loss
3. Sturdy and long life
4. Backet type is usable with vertical piping.

Backet Type

GENERAL SPECIFICATIONS

Y Type (JIS 20K)

1. Applicable fluid : Depend on the type of fluid acceptable


by the flow meter used.
2. Body material : SCS14A(stainless steel castings), SCS16A
3. Screen material : SUS316(stainless steel), SUS316L
4. An origin of main cord.
Nom. size
mm (inch)

Model

103
8
1

SR013C032
SR013C033
SR021C031

203
4

Max. operating St'd screen


Press. MPa
mesh

Flange rating
JIS 10K RF/FF
ASME/JPI150 RF
JIS 20K RF
ASME/JPI150 RF
JIS 30K RF
ASME/JPI300 RF
JIS 10K RF/FF
ASME/JPI150 RF
JIS 20K RF
ASME/JPI150 RF
JIS 30K RF
ASME/JPI300 RF

SR011C031

SR023C032
SR023C033

Y Type (JIS 30K)

1.18
1.37
1.96
1.55

200

2.94
1.18
1.37
1.96
1.55

200

2.94

L [mm]
180
178
184
179
188
185
180
177
184
178
192
188

H [mm]

Ratio of open
area to pipe area

Approx.
Weight.
[kg]

Applicable OVAL
flowmeter model

5.0

152
100

9.6

4.2

39, 41, 45

126
152

5.0

100

2.4

126

1.The dimensions of ASME/JPI flange are the same as those of ASME/JPI 1/2-inch flange.
(Note). For the product complying with regulations such as High Pressure Gas Safety Act, Y type with 30K rating is adopted.

50

5.3

Reference temperature :120C

OUTLINES

Backet Type

Y Type (JIS 20K)

Y Type (JIS 30K)

L
Screen
mesh

Screen
mesh

http://www.oval.co.jp

Head Office (Tokyo): Phone. 81-3-3360-5121. Fax. 81-3-3365-8605


Beijing Office: Phone. 86-10-5867-4711. Fax. 86-10-5867-4713
Overseas Branch Offices: Seoul, Singapore and Taipei

Screen
mesh

GCB001E-8

SMALL SIZE STRAINERS

PRESSURE LOSS

Backet type (10mm)


50

50

Kerosene 16mPas

Heavy oil 18.7mPas

Gasoline 0.6mPas

40

40

30

PkPa

PkPa

Backet type (20mm)

20

30
Heavy oil 18.7mPas

20

Kerosene 16mPas
10

10

0
0.0

0.2

0.4

0.6

0.8

1.0
1.2
1.4 1.6
Flowratem3/h

1.8

2.0

2.2

Gasoline 0.6mPas

0
0.0

2.4

Y type (10mm)

0.2

0.4

0.6

0.8

1.0
1.2
1.4 1.6
Flowratem3/h

2.2

2.4

12
500mPas

500mPas

10

10

PkPa

PkPa

2.0

Y type (20mm)

12

100mPas
6

50mPas
20mPas

3mPas
1mPas
0.4mPas
0

0.1

0.2
0.3
Flowratem3/h

0.4

8
100mPas
6

50mPas
20mPas

10mPas

2
0

1.8

10mPas
3mPas
1mPas
0.4mPas

2
0

0.5

MODEL CODE NUMBER

0.5

1.0
Flowratem3/h

1.5

S R0
Pressure rating
110K
220K
330K

Strainer
Nominal size
0110mm
0220mm
Style
1Backet type
3Y type

Screen material
3SUS316
6SUS316L
9Special

Body material
CSCS14A
ESCS16ASpecial

Always0

WHEN YOU INQUIRE, PLEASE SUPPLY THE FOLLOWING INFORMATION:


1. Application

Acceptance Shipping
Process Control

Others (

8.

2. Applicable Liquid

4. Nominal Size

mm
JIS

K RF, FF

JPI

RF

ASME
6. Materials

9. Max. Operating Pressure

3. Applicable Meter Size

5. Flange Rating

Max. Operating
Temperature

Fluid Viscosity

11.

Physical and/or Chemical


Properties and Quantities
of Foreign Solids Contained

12.

Description of Location
for Installation

RF

Body

mPa s

(layout with pump, air eliminator flowmeter,


valves, etc.)

13. Quantity Desired

Strainer Screen

7. Strainer Net Mesh

10.

MPa

Mesh

14.

Units

Accessories desired

The specification as of Jan., 2013 is stated in this GS Sheet. Specifications and design are subject to change without notice.

Sales Representative:

GS.No.GCB001E