Product Description
Version 2.20
ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright 2012 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.
Revision History
Revision No.
Revision Date
Revision Reason
R1.1
2012-07-30
R1.0
2012-03-30
SJ-20120320184105-002|2012-07-30(R1.1)
Table of Contents
About This Manual ......................................................................................... I
Chapter 1 System Functions ..................................................................... 1-1
1.1 Service Functions............................................................................................... 1-1
1.1.1 Service Access Types............................................................................... 1-1
1.1.2 Service Access Capacity .......................................................................... 1-2
1.1.3 Multi-Service Functions ............................................................................ 1-2
1.2 System Control and Communication Functions .................................................... 1-3
1.3 Power Supply Function ....................................................................................... 1-4
1.4 Overhead Processing Function ........................................................................... 1-4
1.5 Timing and Synchronization Output Function ....................................................... 1-4
1.6 Alarm Input/Output Function ............................................................................... 1-5
1.7 Alarm Concatenation Function ............................................................................ 1-5
1.8 Tandem Connection Monitoring Function ............................................................. 1-5
1.9 Cross-connect Capacity...................................................................................... 1-6
1.10 Protection Function........................................................................................... 1-7
1.10.1 Equipment Level Protections ................................................................... 1-7
1.10.2 Network Level Protections....................................................................... 1-9
Glossary .......................................................................................................... I
III
SJ-20120320184105-002|2012-07-30(R1.1)
IV
SJ-20120320184105-002|2012-07-30(R1.1)
Intended Audience
This manual is intended for:
l
l
Planning engineer
Maintenance engineer
Summary
Recommendations
Related Documentation
The following documentation is related to this manual:
l
l
l
l
l
Unitrans ZXMP S325 (V2.20) SDH Based Multi-Service Node Equipment System
Description
Unitrans ZXMP S325 (V2.20) SDH Based Multi-Service Node Equipment Hardware
Description
Unitrans ZXMP S325 (V2.20) SDH Based Multi-Service Node Equipment Installation
Manual
Unitrans ZXMP S325 (V2.20) SDH Based Multi-Service Node Equipment
Maintenance Manual
Unitrans ZXMP S325 (V2.20) SDH Based Multi-Service Node Equipment Operation
Instructions
Conventions
This document uses the following typographical conventions.
I
SJ-20120320184105-002|2012-07-30(R1.1)
Typeface
Meaning
Italics
Variables in commands. It may also refers to other related manuals and documents.
Bold
Menus, menu options, function names, input fields, option button names, check boxes,
drop-down lists, dialog box names, window names, parameters and commands.
CAPS
Caution: Indicates a potential hazard that, if not avoided, could result in moderate
injuries, equipment damages or partial service interruption.
Note: Provides additional information about a certain topic.
II
SJ-20120320184105-002|2012-07-30(R1.1)
Chapter 1
System Functions
Table of Contents
Service Functions.......................................................................................................1-1
System Control and Communication Functions ..........................................................1-3
Power Supply Function...............................................................................................1-4
Overhead Processing Function ..................................................................................1-4
Timing and Synchronization Output Function..............................................................1-4
Alarm Input/Output Function.......................................................................................1-5
Alarm Concatenation Function ...................................................................................1-5
Tandem Connection Monitoring Function....................................................................1-5
Cross-connect Capacity .............................................................................................1-6
Protection Function ....................................................................................................1-7
PDH services
Ethernet services
ATM services
Rate
STM-1 (optical/electrical)
155520 kbit/s
STM-4
622080 kbit/s
STM-16
2488320 kbit/s
E3
34368 kbit/s
T3
44736 kbit/s
E1
2048 kbit/s
T1
1544 kbit/s
FE
GE
1 Gbit/s
ATMSTM-1
155520 kbit/s
1-1
SJ-20120320184105-002|2012-07-30(R1.1)
Number of Board
Maximum
Maximum
Type
Ports (channels
Access Capacity
Access Capacity
per board)
per Subrack
without Board
Board Protection
Protection
(channel)
Remarks
(channel)
STM-16
without Board
Protection
STM-4
123 or 4
13
without Board
Protection
STM-1(optical)
123 or 4
26
without Board
Protection
STM-1(electrical)
1 or 2
12
10
E3/T3
18
15
E1/T1
21
126
105
10/100 Mbps
36
30
48
without Board
Ethernet interface
(electrical)
100 Mbps
Ethernet interface
Protection
(optical)
ATM interface
24
without Board
Protection
GE optical
16
interface
GE electrical
without Board
Protection
16
interface
without Board
Protection
1-2
SJ-20120320184105-002|2012-07-30(R1.1)
FE optical
Processing
Interface Board
Connector
Board
Maximum
Board ID
ID
Type
Integration
Access Capacity
(channel per
per Subrack
board)
(channel)
24
16
36
SFEx6SED
interface
OIS1x4
LC/PC
OIS1x6
TFEx8
EIFEx4
EITFEx6
FE electrical
interface
SFEx6SED
EIFEx4EIFEx6
TFEx8
EIFEx4
RJ45
48
EITFEx6
ATM service
AP1x4
OIS1x4
LC/PC
24
RSEBSED
LC/PC
16
SED
RJ45
16
optical interface
GE optical
interface
GE electrical
interface
Note:
The ECC provides the function of transmitting network maintenance information
through the data communication channel (DCC) which is the physical layer of ECC.
The DCC carries communication data between NEs, including DCC bytes in the
regenerator section (DCCr) and DCC bytes in the multiplex section (DCCm).
l
l
Implementing the connection of orderwire phones between NEs through the section
overhead bytes E1 and E2 in the SDH frame.
Through the Qx interface, it reports to SMCC (Subnet Management Control Center)
the alarm and performance information of this NE and of the subnet which the NE
1-3
SJ-20120320184105-002|2012-07-30(R1.1)
l
l
belongs to, and receives commands and configurations sent from the SMCC to the
NE and subnet. The Qx interface works for communication between NE and SMCC.
Detecting fan status of the NE. Fan speed can be set to half or full in the EMS. If
the fan stops running when equipment is working, the EMS will report alarm.
Monitoring the board-in-position status and over/under-voltage of the power supply
board.
The system allows configuring ten line clock sources and two external clock sources
at the same time.
l
SJ-20120320184105-002|2012-07-30(R1.1)
The system clock supports the synchronous priority switching and SSM
algorithm-based automatic switching.
In complex networks, the application of SSM algorithm-based automatic switching
can optimize the timing and synchronization distribution of the network, reduce the
difficulty of synchronization planning, and avoid timing loops, thus ensuring the optimal
network synchronization.
l
Clock exporting
ZXMP S325 supports the export of two channels of 2 Mbit/s or 2 MHz external
reference clock signals. The output interface of external reference clock is supplied
by SAIA or SAIB board (system auxiliary interface board).
1-5
SJ-20120320184105-002|2012-07-30(R1.1)
As shown in Figure 1-2, the service interworking between the NE T1 and NE T2 can be
achieved on the backbone network through NE A. It can also be implemented through
forming a direct service route through NE A without establishing another line between T1
and T2 or adding equipment.
1-6
SJ-20120320184105-002|2012-07-30(R1.1)
The cross-connect function of ZXMP S325 also supports network maintenance and test
during networking and operation.
exported to the motherboard. If one OCS16 or OCS4 board fails, the clock is switched to
the other OCS16 or OCS4 board.
The standby board can choose any slot among the six tributary slots
Using this method, the system can implement at most 1:5 tributary protection;
meanwhile, the interface board slot corresponding to the standby board slot need
to be configured with the BIE1x21 board (E1/T1 electrical interface bridge board).
The standby board can choose the dedicated slot for E1/T1 standby board
Using this method, the system can implement at most 1:6 tributary protection;
meanwhile, there is no need to install the BIE1x21 board.
Note:
The protection for E1/T1/FE service processor board belongs to the same protection
type, while the protection for E3/T3/STM-1 (electrical) service processor board belongs
to another protection type. One ZXMP S325 subrack can simultaneously support two
groups of protections with different protection types, but cannot simultaneously support
multiple groups of service protections with the same protection type. For example, one
subrack does not simultaneously support two groups of 1:N protections for E1 service
processor board; however, it supports 1:N protection for E1 service processor board and
for E3 service processor board simultaneously.
1-8
SJ-20120320184105-002|2012-07-30(R1.1)
1-9
SJ-20120320184105-002|2012-07-30(R1.1)
1-10
SJ-20120320184105-002|2012-07-30(R1.1)
Chapter 2
Technical Specifications
Table of Contents
Dimension and Weight ...............................................................................................2-1
Bearing Requirement of Equipment Room..................................................................2-8
Power Supply Requirements ......................................................................................2-8
Environment Requirements ......................................................................................2-14
EMC Requirements ..................................................................................................2-16
Optical Interface Specifications ................................................................................2-19
Electrical Interface Specifications .............................................................................2-23
Interface Jitter Specifications....................................................................................2-30
Clock Specifications .................................................................................................2-37
OA Board Specifications...........................................................................................2-39
Ethernet Performance Specifications........................................................................2-41
RPR Performance Specifications..............................................................................2-44
ATM Characteristics .................................................................................................2-46
External Interface Standards ....................................................................................2-49
59
65
Figure 2-1 illustrates the outline dimensions of the 300 mm-deep cabinet.
2-1
SJ-20120320184105-002|2012-07-30(R1.1)
2-2
SJ-20120320184105-002|2012-07-30(R1.1)
Remarks
59.00
Weight of an empty
cabinet
cabinet
2200 600 300
65.00
Weight of an empty
cabinet
Transmission multifunctional
52.20
51.00
Wall-mounted subrack
3.00
Desktop installation
2.80
9.00
Includes motherboard,
box
components
ZXMP S325 subrack
7.00
With electronic
components
2.50
2.00
Rectifier unit
5.00
Lightning-proof unit
2.50
Motherboard
1.50
Fan box
PCB90 79 1.6
0.52
Includes structural
unit
DC power lightning protection
unit
circuits
Accounted in
subrack weight
2-3
SJ-20120320184105-002|2012-07-30(R1.1)
Board Name
Dimension (mm)
Weight (kg)
NCP
NE control processor
0.430
(thickness)
Front panel: 181.5 (height) 25.4
(width)
SAIA
SAIB
PWRA
System auxiliary
(thickness)
A)
System auxiliary
(thickness)
B)
0.160
0.130
0.160
(depth)
Front panel: 25 (height) 74 (width)
PWRB
0.690
(depth)
Front panel: 25 (height) 74 (width)
FAN
Fan board
0.520
(thickness)
Size after assembly:
21.5 (height) 139.6 (width) 244.8
(depth)
OCS4
OCS16
cross-connect, and
(thickness)
synchronous-clock
board
(width)
cross-connect, and
(thickness)
synchronous-clock
board
(width)
OL1/4x4 4x
4-channel STM-
STM-1
(thickness)
board
OL1/4x4 3x
0.550
0.460
0.485
0.465
(width)
STM-1
OL1/4x4 2x
0.445
STM-1
OL1/4x4 1x
0.425
STM-1
2-4
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
Board Name
Dimension (mm)
OL1/4x4 4x
Weight (kg)
0.485
STM-4
OL1/4x4 3x
0.465
STM-4
0.445
OL1/4x4 2x
STM-4
OL1/4x4 1x
0.425
STM-4
OL16x1
1-channel STM-16
(thickness)
0.410
processor
(thickness)
0.355
LP1x2
1-channel STM-1
optical interface
(thickness)
board
processor
(thickness)
0.125
0.375
LP4x1
2-channel STM-1
optical interface
(thickness)
board
processor
(thickness)
0.145
0.360
LP4x2
1-channel STM-4
optical interface
(thickness)
board
processor
(thickness)
0.125
0.380
2-5
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
Board Name
Dimension (mm)
Weight (kg)
OIS4x2
2-channel STM-4
0.145
optical interface
(thickness)
board
4-channel STM-1
optical interface
(thickness)
board
6-channel STM-1
optical interface
(thickness)
board
Optical booster
amplifier OBA12
(thickness)
OIS1x4
OIS1x6
OBA12
0.185
0.250
0.490
Optical booster
amplifier OBA14
(thickness)
0.490
STM-1 bridge
interface board
(thickness)
0.105
EPE1x2175
EPE1x21120
2-channel STM-1
electrical interface
(thickness)
switching board
21-channel E1
electrical processor
(thickness)
0.140
0.420
21-channel T1
electrical processor
(thickness)
0.400
21-channel E1/T1
electrical processor
(thickness)
0.420
21-channel E1/T1
bridge interface
(thickness)
board
0.090
2-6
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
Board Name
Dimension (mm)
Weight (kg)
ESE1x2175
21-channel E1
0.160
electrical interface
(thickness)
)
ESE1x21120
21-channel E1/T1
electrical interface
switching board
EP3x3
3-channel E3/T3
electrical processor
(thickness)
0.400
ESE3x3
SFEx6PPP
SFEx6GFP
3-channel E3/T3
electrical bridge
(thickness)
interface board
3-channel E3/T3
electrical interface
(thickness)
switching board
board
(thickness)
0.115
0.145
0.430
EIFEx6
EITFEx6
4-channel electrical
interface board of
(thickness)
fast Ethernet
6-channel electrical
interface board of
(thickness)
fast Ethernet
6-channel switching
(thickness)
fast Ethernet
0.150
0.140
0.190
(width)
BIFE
Bridge interface
(thickness)
0.090
4 STM-1 ports
(thickness)
0.430
2-7
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
Board Name
Dimension (mm)
Weight (kg)
RSEB
Ethernet processor
0.735
(thickness)
Front panel: 181.5 (height) 25.4
(width)
SED
Enhanced smart
Ethernet board
(thickness)
0.640
8-channel
transparent board
(thickness)
of fast Ethernet
0.380
(width)
Board Name
Max Power
Max Power
Consumption
Consumption (45
(25 C) (W)
C) (W)
Remarks
NCP
NE control processor
4.37
4.50
SAIA
System auxiliary
2.16
2.22
The impedance of
interface board
2-8
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
SAIB
Board Name
System auxiliary
Max Power
Max Power
Consumption
Consumption (45
(25 C) (W)
C) (W)
0.97
1.00
interface board
Remarks
The impedance of
clock input/ output
interface is 120
PWRA
3.00
3.09
15.80
16.60
board
PWRB
FAN
Fan board
8.04
8.28
0.80
0.82
OCS4
16.17
16.66
STM-1 application
16.95
17.46
STM-4 application
20.88
21.51
9.60
9.89
7.71
7.94
6.74
6.94
5.78
5.95
11.76
12.11
10.04
10.34
8.32
8.57
6.56
6.76
14.11
14.39
cross-connect, and
synchronous clock
board
OCS16
OL1/4x4 4x
4-channel STM-
STM-1
OL1/4x4 3x
board
STM-1
OL1/4x4 2x
STM-1
OL1/4x4 1x
STM-1
OL1/4x4 4x
STM-4
OL1/4x4 3x
STM-4
OL1/4x4 2x
STM-4
OL1/4x4 1x
STM-4
OL16x1
1-channel STM-16
optical line board
2-9
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
LP1x1
OIS1x1
Board Name
Max Power
Max Power
Consumption
Consumption (45
(25 C) (W)
C) (W)
processor
OIS1x1)
OIS1x1)
processor
OIS1x2)
OIS1x2)
processor
OIS4x1)
OIS4x1)
processor
OIS4x2)
OIS4x2)
2.16
2.22
Remarks
1-channel STM-1
optical interface board
LP1x2
OIS1x2
2-channel STM-1
optical interface board
LP4x1
OIS4x1
1-channel STM-4
optical interface board
LP4x2
OIS4x2
2-channel STM-4
optical interface board
OIS1x4
4-channel STM-1
Provides optical
OIS1x6
6-channel STM-1
3.05
3.14
Provides optical
OBA12
3.98
8.98
OBA12
OBA14
no cooling
4.94
9.94
OBA14
BIS1
no cooling
2.59
2.67
2.20 (4.62)
2.26 (4.76)
The numbers in
board
ESS1x2
2-channel STM-1
electrical interface
parentheses are
switching board
consumptions after
switching
2-10
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
EPE1x2175
Board Name
21-channel E1 electrical
Max Power
Max Power
Consumption
Consumption (45
(25 C) (W)
C) (W)
4.42
4.55
The interface
processor
EPE1x21120
Remarks
impedance is 75
6.12
6.30
The interface
impedance is 120
EPT1x21
21-channel T1 electrical
6.10
6.28
The interface
processor
impedance is 100
EP1EBx21
21-channel E1/T1
7.39
7.61
electrical processor
BIE1x21
21-channel E1/T1
interface bridge board
ESE1x2175
21-channel E1 electrical
0.50 (6.29)
0.51 (6.48)
The interface
interface switching
impedance is 75
board
The numbers in
parentheses are
consumptions after
switching
ESE1x21120
21-channel E1/T1
The interface
electrical interface
impedance is 120
switching board
or 100
The numbers in
parentheses are
consumptions after
switching
EP3x3
3-channel E3/T3
6.96
7.17
3.00
3.09
2.13 (4.13)
2.19 (4.25)
The numbers in
electrical processor
BIE3x3
3-channel E3/T3
electrical interface
bridge board
ESE3x3
3-channel E3/T3
electrical interface
parentheses are
switching board
consumptions after
switching
SFEx6PPP
SFEx6GFP
19.54
20.13
21.27
21.91
2-11
SJ-20120320184105-002|2012-07-30(R1.1)
Board ID
Board Name
EIFEx4
4-channel Ethernet
Max Power
Max Power
Consumption
Consumption (45
(25 C) (W)
C) (W)
0.43 (2.28)
0.44 (2.35)
Remarks
The numbers in
electrical interface
parentheses are
board
consumptions after
switching
EIFEx6
6-channel Ethernet
EITFEx6
0.05
0.05
Provides electrical
electrical interface
board
board
6-channel FE handover
0.46 (2.90)
0.47 (3.00)
board
BIFE
Ethernet interface
bridge board
AP1x4
4-channel ATM
16.52
17.02
26.83
27.63
20.88
21.51
16.80
17.65
processor
RSEB
SED
Enhanced smart
Ethernet board
TFEx8
8-channel fast
Ethernet transparent
transmission board
The weights of OCS4, OCS16, optical line boards, and optical interface boards include the weights of SFP modules.
Power consumptions of boards shall be higher during equipment startup and in low temperature environment. The
refore, the power capacity provided by the equipment should be 1.5 to 1.8 times the power consumptions listed in
the table.
Board/Part
Unit
Quantity
NCP
Piece
SAIA
Piece
PWRA
Piece
OCS4 (S-4.1)
Piece
2-12
SJ-20120320184105-002|2012-07-30(R1.1)
S.N.
Board/Part
Unit
Quantity
LP41
Piece
OIS4x1 (S-4.1)
Piece
EPE1x21 (75)
Piece
ESE1x21 (75)
Piece
SFEx6 (GFP)
Piece
10
EIFEx4
Piece
11
FAN
Piece
12
Set
13
Set
subrack including MB
and fan)
14
Board/Part
Unit
Quantity
NCP
Piece
SAIA
Piece
PWRA
Piece
OCS16
Piece
OL1/4x4 (4xS-1.1,LC)
Piece
OL1/4x4 (4xS-4.1,LC)
Piece
EPE1x21 (75)
Piece
ESE1x21 (75)
Piece
SED
Piece
10
EIFEx6
Piece
11
FAN
Piece
12
Set
13
Set
2-13
SJ-20120320184105-002|2012-07-30(R1.1)
Board/Part
Unit
Quantity
NCP
Piece
SAIA
Piece
PWRA
Piece
OCS16
Piece
OL16 (L-16.2,LC)
Piece
OL1/4x4 (4xS-1.1,LC)
Piece
OL1/4x4 (4xS-4.1,LC)
Piece
EPE1x21 (75)
Piece
ESE1x21 (75)
Piece
10
SED
Piece
11
EIFEx6
Piece
12
FAN
Piece
13
Set
14
Set
The voltage differences among the lightning protection ground, the system
working ground, and the -48 V GND should be less than 1 V.
2-14
SJ-20120320184105-002|2012-07-30(R1.1)
Specification
-5 C ~ +45 C
-5 C ~ +45 C
multifunctional box
Working Temperature (inside outdoor power
-40 C ~ +45 C
cabinet)
Relative Humidity
5% ~ 95%
In normal conditions, the temperature and humidity are measured at 1.5 m above the floor and 0.4 m
near the equipment.
Gas
Average (mg/m3)
Maximum (mg/m3)
SO2
0.2
1.5
H2S
0.006
0.030
NO2
0.04
0.15
NH3
0.05
0.15
Cl2
0.01
0.30
The equipment room should be always kept clean, with doors and windows tightly
sealed.
2-15
SJ-20120320184105-002|2012-07-30(R1.1)
Product storage environment: 1K5, 1Z1, 1B2, 1C2, 1S3, or 1M3. The storage duration
is 180 days.
Product transportation environment: 2K4P, 2B2, 2C2, 2S3, or 2M3. The transportation duration is 30 days.
Product usage environment: 3K5, 3Z2, 3Z7, 3B2, 3C2, 3S2, or 3M3. The usage
duration is 10 years.
2.5.1 EMS
ESD Resistivity
The Electrical Static Discharge (ESD) resistivity indexes of ZXMP S325 are listed in Table
2-10.
2-16
SJ-20120320184105-002|2012-07-30(R1.1)
Contact Discharge
Air Discharge
Criterion
6 kV
8 kV
Performance criterion B
Amplitude Modulation
Criterion
10 V/m
Performance criterion A
Repetition Frequency
Criterion
1 kV
5 kHz
Performance criterion B
Repetition Frequency
Criterion
2 kV
5 kHz
Performance criterion B
Table 2-14 Electrical Transient Burst Resistivity at Signal Cable and ControlCablePorts
Generator Waveform: 5 ns/50 ns
Test Voltage
Repetition Frequency
Criterion
1 kV
5 kHz
Performance criterion B
Surge Resistivity
The surge resistivity indexes of ZXMP S325 are listed in Table 2-15 to Table 2-18.
2-17
SJ-20120320184105-002|2012-07-30(R1.1)
Test Voltage
Criterion
Line to line
0.5 kV
Performance criterion B
Line to ground
1 kV
Performance criterion B
Test Voltage
Criterion
Line to ground
1 kV
Performance criterion B
Line to ground
2 kV
Performance criterion R
Test Voltage
Criterion
Line to line
2 kV
Performance criterion B
Line to ground
Test Voltage
Criterion
Line to line
1 kV
Performance criterion B
Line to ground
Amplitude Modulation
Criterion
3V
Performance criterion A
2-18
SJ-20120320184105-002|2012-07-30(R1.1)
2.5.2 EMI
Conductive Emission Electromagnetic Interference
The indexes of conductive emission electromagnetic interference of the ZXMP S325 are
listed in Table 2-20.
Table 2-20 Conductive Emission Electromagnetic Interference
Test Frequency (MHz)
Threshold (dBV)
Quasi-Peak Value
Mean Value
0.15~0.5
79
66
0.5~30
73
60
These indexes satisfy the requirements specified in the international standard of CISPR 22 CLASS
A.
Test Distance: 3 m
30~230
40
50
230~1000
47
57
These indexes satisfy the requirements specified in the international standard of CISPR 22 CLASS
A.
Table 2-22 lists the STM-16 optical modules supported by ZXMP S325.
2-19
SJ-20120320184105-002|2012-07-30(R1.1)
Light Nominal
Transmission
Type
Wavelength
Distance (km)
Connector Type
Service
Capacity
(nm)
(Channel per
board)
S-16.1
1310
15
LC/PC
S-16.2
1550
15
LC/PC
L-16.1
1310
40
LC/PC
L-16.2
1550
80
LC/PC
L-16.2U
1550
150
LC/PC
CWDM nS1-2XX
Compliant with
40
LC/PC
80
LC/PC
Compliant with
the ITU-T Recommendation
G.695
Table 2-23 lists the STM-4 optical modules supported by ZXMP S325.
Table 2-23 STM-4 Optical Modules Supported by ZXMP S325
Optical Module
Light Nominal
Transmission
Type
Wavelength
Distance (km)
Connector Type
Service
Capacity
(nm)
(Channel per
board)
S-4.1
1310
15
LC/PC or SC/PC
123 or 4
L-4.1
1310
40
LC/PC or SC/PC
123 or 4
L-4.2
1550
80
LC/PC or SC/PC
123 or 4
Single-fiber
1310/1550
15
LC/PC or SC/PC
123 or 4
1310/1550
40
LC/PC or SC/PC
123 or 4
bidirectional
optical module
S-4.1
Single-fiber
bidirectional
optical module
L-4.1
Table 2-24 lists the STM-1 optical modules supported by ZXMP S325.
2-20
SJ-20120320184105-002|2012-07-30(R1.1)
Light Nominal
Transmission
Type
Wavelength
Distance (km)
Connector Type
Service
Capacity
(nm)
(Channel per
board)
S-1.1
1310
15
LC/PC or SC/PC
123 or 4
L-1.1
1310
40
LC/PC or SC/PC
123 or 4
L-1.2
1550
80
LC/PC or SC/PC
123 or 4
Single-fiber
1310/1550
15
LC/PC or SC/PC
123 or 4
1310/1550
40
LC/PC or SC/PC
123 or 4
bidirectional
optical module
S-1.1
Single-fiber
bidirectional
optical module
L-1.1
General transmitter pulse shape characteristics include rise time, fall time, pulse
overshoot, pulse undershoot, and ringing. All these may deteriorate the sensitivity of the
receiver and therefore should be restricted.
2-21
SJ-20120320184105-002|2012-07-30(R1.1)
STM-1
STM-4
STM-16
x1/x4
0.15/0.85
0.25/0.75
x2/x3
0.35/0.65
0.40/0.60
y1/y2
0.20/0.80
0.20/0.80
0.25/0.75
x3x2
0.2
Diagram Mask
STM-1
Mean optical
STM-4
STM-16
S-1.1/
L-1.1/
S-4.1/
L-4.1/L-
S-16.1/
L-16.1/L-16.2
nS1-2XX/
S-1.2
L1.2
S-4.2
4.2
S-16.2
/L-16.2U
nL1-2XX
-15~-8
-5~0
-15~-8
-3~+2
-5~0
-2~+3
0~+5
launched power
(dBm)
STM-1
Extinction ratio
STM-4
STM-16
S-1.1/S-1.2
L-1.1/L1.2
S-4.1/S-4.2
L-4.1/L-4.2
8.2
10
8.2
10
8.2
(dB)
STM-1
STM-4
S-1.1/S-1.2
Receiver sensitivity
-28
STM-16
L-1.1/L-1.2/L-
S-16.1/S-
L-16.
L-16.2/L-16.2U/
1.3
16.2/nS1-2XX
nL1-2XX
-18
-27
-28
-34
-28
(dBm)
BER=110-10
S-1.1/S-1.2
Overload (dBm)
STM-4
STM-1
-8
L-1.1/L-1.2/L-1.3
-10
-8
STM-16
S-16.1/ S-16.2/
L16.1/L-16.2/L-
nS1-2XX
16.2U/ nL1-2XX
-9
BER=110-10
Signal Type
Code Pattern
Abbreviation
E0
64
AMI
T1
1544
B8ZS
T3
44736
B3ZS
E1
2048
HDB3
E3
34368
STM-1 (E)
155520
CMI
Permitted Attenuation
Permitted Frequency
(kbit/s)
Deviation of Input
Tolerance of Output
Interface (ppm)
Interface (ppm)
attenuation)
1544
Within 32
Within 32
2048
Within 50
Within 50
34368
Within 20
Within 20
44736
Within 20
Within 20
155520
0~12.7, 78 MHz
Within 20
Within 20
1 ppm=110-6
2-24
SJ-20120320184105-002|2012-07-30(R1.1)
2048
Input interface
Output interface
34368
Input interface
Output interface
44736
Input interface
Output interface
155520
Input/output
TestFrequencyRange
Reflection Attenuation
(kHz)
(dB)
51.2~102.4
12
102.4~2048
18
2048~3072
14
51~102
102~3072
860~1720
12
1720~34368
18
34368~51550
14
1720~51550
102~3072
860~1720
12
1720~34368
18
34368~51550
14
1720~51550
102~3072
8000~240000
15
interface
2048
18
34368
20
2-25
SJ-20120320184105-002|2012-07-30(R1.1)
2-26
SJ-20120320184105-002|2012-07-30(R1.1)
Figure 2-4 Output Pulse Mask at the 2048 kbit/s Electrical Interface
2-27
SJ-20120320184105-002|2012-07-30(R1.1)
Figure 2-5 Output Pulse Mask at the 34368 kbit/s Electrical Interface
2-28
SJ-20120320184105-002|2012-07-30(R1.1)
Figure 2-6 Output Pulse Mask at the 44736 kbit/s Electrical Interface
2-29
SJ-20120320184105-002|2012-07-30(R1.1)
Figure 2-7 Mask of a Pulse Corresponding to a Binary 0 at the 155520 kbit/s Electrical
Interface
Figure 2-8 Mask of a pulse Corresponding to a Binary 1 at the 155520 kbit/s Electrical
Interface
UIp-p
A0
Frequency (Hz)
A1
A2
A3
f10
f9
Pseudof8
f1
f2
f3
f4
(kbit/s)
1544
random
Signal
18
0.1
1.2
10
120
6k
40k
0.01
1.66
20
2.4k
18k
100k
215-1
10-5
2048
36.9
1.5
0.2
18
4.88
10-3
34368
618.6
1.5
0.15
100
1k
10k
800k
223-1
44736
18
0.1
1.2
10
600
30k
400k
10-5
2-31
SJ-20120320184105-002|2012-07-30(R1.1)
Table 2-35 Input Jitter and Wander Tolerance (UIP-P) of SDH Terminal Multiplexer
Interface
A0
A1
A2
A3
A4
STM-1 (E)
2800
311
39
1.5
0.075
STM-1 (O)
2800
311
39
1.5
0.15
STM-4 (O)
11200
1244
156
1.5
0.15
STM-16 (O)
44790
4977
622
1.5
0.15
Table 2-36 Frequency (Hz) of Input Jitter and Wander Tolerance of SDH Terminal Multiplexer
Inter-
f0
f12
f11
f10
f9
f8
f1
f2
f3
f4
1.210-5
1.7810-4
1.610-3
1.5610-2
0.125
19.3
500
3.25k
65k
1.3M
1.210-5
1.7810-4
1.610-3
1.5610-2
0.125
19.3
500
6.5k
65k
1.3M
1.210-5
1.7810-4
1.610-3
1.5610-2
0.125
9.65
1000
25k
250k
5M
1.210-5
1.7810-4
1.610-3
1.5610-2
0.125
12.1
5000
100k
1M
20M
face
STM-1
(E)
STM-1
(O)
STM-4
(O)
STM-16
(O)
2-32
SJ-20120320184105-002|2012-07-30(R1.1)
Table 2-37 Input Jitter Tolerances of STM-1, STM-4 and STM-16 Regenerators
STM Interface
f1 (kHz)
f2 (kHz)
A1 (UIP-P)
A2 (UIP-P)
STM-1
65
6.5
0.15
1.5
12
1.2
0.15
1.5
250
25
0.15
1.5
12
1.2
0.15
1.5
1000
100
0.15
1.5
12
1.2
0.15
1.5
STM-4
STM-16
STM-N interface inherent output jitter of SDH equipment is defined as the jitter at the
STM-N output interface of the equipment when there is no input jitter. For the ADM
and TM equipment of ZXMP S325, the STM-N interface inherent output jitter satisfies
the requirements listed in Table 2-38.
Table 2-38 STM-N Interface Inherent Output Jitter Specifications of SDH Equipment
STM Interface
Test Filter
STM-1
0.3
0.1
1 kHz ~ 5 MHz
0.3
0.1
5 kHz ~ 20 MHz
0.5
1 MHz ~ 20 MHz
0.1
STM-4
STM-16
Due to the randomness of jitter, the test value might exceed the specifications. It is acceptable
as long as over 99% test values satisfy the specifications during the test (about 1 to 2 minutes).
The STM-N network interface output jitter of SDH equipment is defined as the output
jitter value measured at the output interface of any STM-N level in the SDH network.
2-33
SJ-20120320184105-002|2012-07-30(R1.1)
For ADM and TM equipment of ZXMP S325, the STM-N network interface output jitter
satisfies the requirements listed in Table 2-39.
Table 2-39 STM-N Network Interface Output Jitter Specifications of SDH Equipment
STM Interface
f1 (Hz)
f3 (Hz)
F4 (MHz)
B1 (UIp-p)
B2 (UIp-p)
STM-1 optical
500
65 k
1.3
1.5
0.15
500
65 k
1.3
1.5
0.075
1k
250 k
1.5
0.15
5k
1M
20
1.5
0.15
interface
STM-1 electrical
interface
STM-4 optical
interface
STM-16 optical
interface
Due to the randomness of jitter, the test value might exceed the specifications. It is acceptable
as long as over 99% test values satisfy the specifications during the test (about 1 to 2 minutes).
For REG equipment, when the test filter employs a 12 kHz high-pass filter, the root
mean square caused by jitter should be no more than 0.01 UI.
Tolerance
Interface
(ppm)
(kbit/s)
f1 (Hz)
f3 (Hz)
f4 (Hz)
f1 ~ f4
f3 ~ f4
1544
22
10
8k
40 k
0.7
2048
50
20
18 k
100 k
To be
0.075
determined
34368
20
100
10 k
800 k
To be
0.075
determined
44736
20
10
30 k
400 k
0.4
0.1
Bit Rate
terface
Toler-
Octaves
(kbit/s)
ance
f1 (Hz)
f3 (Hz)
f4 (Hz)
(ppm)
2048
50
20
18 k
100 k
0.4
0.4
0.4
0.075
0.075
0.075
34368
20
100
10 k
800 k
0.4
0.4
0.4
0.75
0.075
0.075
0.075
0.075
Test sequence
Bit
High-Pass Filter 20
Inter-
Rate
dB/10 Octaves
face
Toler-
(kbit/s)
ance
f1
f3 (Hz)
f4
(Hz)
UIp-p (f3 ~
(Hz)
f4)
(ppm)
1544
32
10
8k
40 k
1.3
1.3
1.9
1.9
To be determined
Test sequence
h,
h,
h, pe-
periodic
periodic
riodic
and
and
and can-
regular
added
celled
Bit
High-Pass
Inter-
Rate
Filter 20
face
Toler-
dB/10
(kbit/s)
ance
Octaves
(ppm)
44736
20
f1
f3
f4 (
Hz)
H-
H-
z)
z)
10
30
40
0k
UIp-p (f3 ~
f4)
1.3
1.3
1.3
1.3
To be determined
2-35
SJ-20120320184105-002|2012-07-30(R1.1)
PDH
Bit
High-Pass
Inter-
Rate
Filter 20
face
Toler-
dB/10
(kbit/s)
ance
Octaves
(ppm)
f1
f3
f4 (
Hz)
H-
H-
z)
z)
Test sequence
UIp-p (f3 ~
f4)
h,
h,
h,
h,
h,
h,
peri-
peri-
peri-
peri-
peri-
peri-
odic
odic
odic
odic
odic
odic
and
and
and
and
and
and
reg-
reg-
can-
reg-
add-
can-
u-
u-
cel-
ular
ed
cel-
lar (
lar (
led (
87-3
87-3
87-3
co-
co-
code
de
de
pat-
pat-
pat-
tern)
tern)
tern)
led
fc (kHz)
P (dB)
130
0.1
30
0.1
2-36
SJ-20120320184105-002|2012-07-30(R1.1)
STM-N
STM-4
STM-16
fc (kHz)
P (dB)
500
0.1
30
0.1
2000
0.1
30
0.1
All the timings of SDH system should conform to the primary reference clock (PRC)
described in G.811.
Output Jitter
When there is no input jitter, the inherent jitter of the 2 MHz or 2 Mbit/s clock output interface
in ZXMP S325 should not exceed 0.05 UIP-P. The test is conducted at the time interval of
60 s, using a single pole bandpass filter with 20 Hz and 100 kHz turnover frequencies.
Specification
Permissible input
interface attenuation
complies with the frequency square root rule. When using cables with
attenuation range of 0 dB ~ 6 dB, no bit error or clock lock loss occurs in
the equipment.
Permissible input
4.6 ppm
interface frequency
deviation
Signal bit rate tolerance of
4.6 ppm
Item
Specification
Output interface
waveform
1 ppm=110-6
Note:
For 2 Mbit/s external timing source, the timing reference failure refers to the signal loss of
synchronous clock input interface; for the timing recovery through STM-N line signals, the
timing reference failure refers to the loss of STM-N signals that bear timing signals, or the
AIS occurrence.
Observation Interval
40 ns
0.1 s<1 s
40 0.1 ns
1 s<100 s
25.25 0.2 ns
100 s<1000 s
Observation Interval
0.5 ns
0.1 s<100 s
50 ns
>100 s
Observation Interval
3.2 ns
0.1 s<25 s
0.64 0.5 ns
25 s<100 s
2-38
SJ-20120320184105-002|2012-07-30(R1.1)
TDEV Limit
Observation Interval
6.4 ns
100 s<1000 s
l
l
SJ-20120320184105-002|2012-07-30(R1.1)
Unit
OBA12
OBA14
Remark
Working wavelength
nm
1530~1562
1530~1562
dBm
-12~+4
-12~+4
dBm
12
14
dB
9~12.5
11~14.5
Can be directly
value)
Adjustment range of optical
launched power
adjusted.
dB
0.5
0.5
dBm
<3
<3
LC/PC
LC/PC
Working environment
-10~+60
-10~+60
temperature
Unit
OPA38
Remark
Working wavelength
nm
1550.12
dBm
-38~-20
dBm
-12
dB
-15~-9
dB
0.5
LC/PC
Working environment
-10~+60
value)
Adjustment range of optical
launched power
temperature
2-40
SJ-20120320184105-002|2012-07-30(R1.1)
SFEx6
64
1522
SED
64
RSEB
64
TFEx8
64
Board Throughput
l
l
l
l
For the ZXMP S325, when the ports of smart fast Ethernet board (SFEx6) are
configured with 46 VC-12s, the port throughput can reach the line speed of 100
Mbit/s.
When the enhanced smart Ethernet board (SED) is configured with GE services, the
port throughput can reach the line speed of 1 Gbit/s.
When the RSEB board is configured with GE services, the port throughput can reach
the line speed of 1 Gbit/s.
When the ports of Ethernet transparent transmission board (TFEx8) are configured
with 63 VC-12s, the port throughput can reach the line speed of 100 Mbit/s.
Note:
The flow control function of port must be disabled while testing the port throughput.
2-41
SJ-20120320184105-002|2012-07-30(R1.1)
Note:
The flow control function of port must be disabled when conducting the packet loss ratio
test.
Delay
Delay refers to the maximum acceptable delay under the prerequisite that data is normally
received. There is no specific criterion for delay. However, it should be as small as possible
under certain conditions.
Trunk Specification
Trunk refers to the transmission of large-capacity Ethernet services by binding multiple
Ethernet interfaces. The Ethernet ports in the same Trunk group have the same VLAN
configuration attributes. They cannot interwork with the Ethernet ports that do not belong
to the same Trunk group.
l
l
The SFEx6 board supports two trunk groups at most at the user side, and each group
can support one to four Ethernet ports.
The SED board supports ten trunk groups at most at the user side, and each group
can support one to four Ethernet ports. The SED board supports eight trunk groups
at most at the system side, and each group can support two, four, or eight Ethernet
ports.
The RSEB board can support three trunk groups at most at the user side. When
supporting two trunk groups, one trunk group supports tow Ethernet ports, and the
other trunk group supports four Ethernet ports; when supporting three trunk groups,
each trunk group supports two Ethernet ports.
2-42
SJ-20120320184105-002|2012-07-30(R1.1)
VLAN Priority
Under the prerequisite that the QoS function is enabled, when services from multiple
sources are converged at one transmit port, the port can transmit these services according
to the preset VLAN priorities and bandwidths. Once the total traffic exceeds the transmit
bandwidth of the port, the port will discard the services with lower priorities and over
bandwidth limit, to ensure the normal transmission of services with higher priorities.
The SFEx6 board, the SED board, and the RSEB board of ZXMP S325 support the
configurations of VLAN priority and bandwidth proportion.
2-43
SJ-20120320184105-002|2012-07-30(R1.1)
Burst Interval
The burst interval refers to the time interval between the frame bursts of the Ethernet port
at the user side. It is generally defined as the minimum frame interval between Ethernet
frames.
Table 2-52 lists the burst intervals.
Table 2-52 The Minimum Frame Interval between Ethernet Frames
Ethernet Rate (Unit: Mbit/s)
10
9.6
100
0.96
1000
0.096
2-44
SJ-20120320184105-002|2012-07-30(R1.1)
Service Characteristics
l
Service types
The total number of type-A and type-C services supported by the RSEB board of
ZXMP S325 is 1000. And the number of type-B services supported is eight.
Table 2-53 compares different RPR service types.
Table 2-53 Comparisons of RPR Service Types
RPR
Throughput
Delay
Jitter
Loss of Frame
Extremely low,
Extremely low,
Extremely low
guarantee
with guarantee
with guarantee
mechanism
mechanism
Low
Variable
Low
No requirement
No requirement
Medium
No requirement
No requirement
High, depends
Service
Type
A0
A1
Can be over
configured; has
higher priority than
C
No guarantee;
depends on the
on the network
network situation
situation
Protection types
The RSEB board provided by ZXMP S325 supports both SDH layer protection and
RPR MAC layer protection. The RPR MAC layer protection supports the wrapping or
steering protection.
Protection configuration
Whether to use RPR MAC layer protection and SDH layer protection simultaneously
can be configured in the EMS. When these two protections are configured to be used
2-45
SJ-20120320184105-002|2012-07-30(R1.1)
simultaneously, delaying the switching time of RPR MAC layer protection can support
the switching between layers and thus guarantee that these two switchings will not
overlap.
l
Protection principle
When network fault occurs, the SDH layer protection will launch first. The delay
of RPR MAC layer protection switching is the waiting time between the service
failure detection and switching launch. During this period, if service recovers, the
switching will not occur.
If the SDH layer protection fails after the delay of RPR MAC layer protection
switching, the RPR MAC layer protection will launch.
When the service recovers and keeps normal after the switching restore time had
passed, the service will return to the previous working path from the protection
path.
The switching restore time is the waiting time between the service recovery and
the service fault status clearance (i.e. the cancellation of protection status).
During this period, if the service fails, the protection will not be cancelled any
more.
Protection delay
The delay of protection between layers ranges from 0 ms to200 ms. The default value
is 0 ms. The stepping is 10 ms.
The range of VPI value for network-to-network interface (NNI) is 1 to 4095. The range of
VPI value for user-to-network interface (UNI) is 1 to 255. The range of VCI value is 1 to
16383.
The AP1x4 board of ZXMP S325 meets the value range requirements above.
VP/VC Multicast
l
The AP1x4 board provided by ZXMP S325 supports both the VP/VC spatial multicast and
logical multicast.
The ATM services transmission priority is: CBR > rt-VBR > nrt-VBR > UBR. When the
transmission flow of ATM services exceeds the maximum cell flow traffic of the ATM
equipment, the ATM equipment will discard cells according to the priority of services once
the congestion occurs.
The AP1x4 board provided by the ZXMP S325 has the above function.
VP-Ring Protection
The VP-Ring protection adopts the principle of concurrent transmitting and preferred
receiving with alarm supervision. The standby VP connection of the receive direction will
be selected when alarms are found, such as VP-AIS (VP alarm indication signal), LOS
(loss of signal), LOF (loss of frame), OOF (out of frame), and LAIS (line alarm indication
signal). When the alarms disappear and no alarm appear after the switching restore time,
the previous active VP connection will recover automatically.
The AP1x4 board supports the enable and restore of VP-Ring protection after configured
in the network management system.
2-47
SJ-20120320184105-002|2012-07-30(R1.1)
Note:
The ATM service type of CBR is recommended for testing the VP-Ring protection
l
l
Note:
The ATM service type of CBR is recommended for testing the protection between
layers.
The switching restore time refers to the restore time of the ATM layer protection.
2-48
SJ-20120320184105-002|2012-07-30(R1.1)
Standard
Description
ITU-T G.707
kbit/s622080 kbit/s2488320
kbit/s)
hierarchy (SDH)
ITU-T G.957
ITU-T G.691
ITU-T G.692
ITU-T G.825
ITU-T G.707
kbit/s)
ITU-T G.703
ITU-T G.825
ITU-T G.703
kbit/s2048 kbit/s34368
kbit/s44736 kbit/s)
ITU-T G.704
ITU-T G.825
GB 7611-87
ITU-T G.703
synchronous interface
2-49
SJ-20120320184105-002|2012-07-30(R1.1)
Interface Types
Standard
Description
phone
Ethernet Interfaces
2-50
SJ-20120320184105-002|2012-07-30(R1.1)
Appendix A
Standards and
Recommendations
Table A-1 lists the ITU-T recommendations and other standards that ZXMP S325 is
compliant with.
Table A-1 Standards and Recommendations Complied by ZXMP S325
Recommendation
Description
Version
ITU-T G.703
11/2001
interfaces
ITU-T G.704
10/1998
10/2000
04/1991
10/2000
(SDH)
ITU-T G.708
06/1999
03/1993
transmission systems
ITU-T G.774
02/2001
07/1999
(SDH) networks
ITU-T G.781
06/1999
ITU-T G.783
10/2000
07/1999
ITU-T G.785
11/1996
digital environment
A-1
SJ-20120320184105-002|2012-07-30(R1.1)
Recommendation
Description
Version
ITU-T G.803
03/2000
03/2000
ITU-T G.806
10/2000
08/1996
ITU-T G.811
09/1997
ITU-T G.812
06/1998
06/1998
ITU-T G.823
03/2000
03/2000
03/2000
03/2000
03/2000
sections
ITU-T G.831
03/2000
10/1998
multiplexing structures
ITU-T G.841
10/1998
architectures
ITU-T G.842
04/1997
ITU-T G.957
07/1999
A-2
SJ-20120320184105-002|2012-07-30(R1.1)
Glossary
ADM
- Add/Drop Multiplexer
AIS
- Alarm Indication Signal
ATM
- Asynchronous Transfer Mode
BER
- Bit Error Rate
CBR
- Constant Bit Rate
CDV
- Cell Delay Variation
CER
- Cell Error Ratio
CLR
- Cell Loss Ratio
CMR
- Cell Misinsertion Ratio
CTD
- Cell Transfer Delay
DC
- Direct Current
DCC
- Data Communications Channel
DNI
- Dual Node Interconnection
DXC
- Digital Cross Connect
ECC
- Embedded Control Channel
EMC
- Electromagnetic Compatibility
EMI
- Electromagnetic Interference
I
SJ-20120320184105-002|2012-07-30(R1.1)
EMS
- Electromagnetic Susceptibility
EUT
- Equipment Under Test
FE
- Fast Ethernet
GE
- Gigabit Ethernet
ITU-T
- International Telecommunication Union - Telecommunication Standardization
Sector
L2
- Layer 2
LAIS
- Line Alarm Indication Signal
LOF
- Loss Of Frame
LOS
- Loss Of Signal
MAC
- Medium Access Control
MCU
- Micro Control Unit
MS
- Mobile Station
MTIE
- Maximal Time Interval Error
NE
- Network Element
NNI
- Network Node Interface
OA
- Optical Amplifier
OBA
- Optical Booster Amplifier
OOF
- Out Of Frame
OPA
- Optical Pre-Amplifier
II
SJ-20120320184105-002|2012-07-30(R1.1)
Glossary
PCM
- Pulse Code Modulation
PDH
- Plesiochronous Digital Hierarchy
PRC
- Primary Reference Clock
QoS
- Quality of Service
REG
- REGenerator
RPR
- Resilient Packet Ring
SDH
- Synchronous Digital Hierarchy
SEC
- SDH Equipment Clock
SMCC
- Sub-network Management Control Center
SNC
- Sub-Network Connection
SNCP
- Sub-Network Connection Protection
SSM
- Synchronization Status Message
STM
- Synchronous Transport Module
STM-N
- Synchronous Transport Module, level NN=1, 4, 16, 64
TDEV
- Time Deviation
TM
- Terminal Multiplexer
UBR
- Unspecified Bit Rate
UNI
- User Network Interface
VC
- Virtual Channel
III
SJ-20120320184105-002|2012-07-30(R1.1)
VCI
- Virtual Channel Identifier
VLAN
- Virtual Local Area Network
VP
- Virtual Path
VP-AIS
- Virtual Path - Alarm Indication Signal
VPI
- Virtual Path Identifier
nrt-VBR
- non-real time Variable Bit Rate
rt-VBR
- real-time Variable Bit Rate
IV
SJ-20120320184105-002|2012-07-30(R1.1)