EQUIPMENT REQUIRED:
Three-phase Rotor Winding Motor
Magnetic Powder Brake Unit
Brake Control Unit
Three-phase AC/DC Power Supply
Three-phase Power Supply Module
Three-pole Current Limit Protection Switch Module
Digital Power Analysis Meter
Coupling
Coupling Guard
Shaft End Guard
Connecting Leads Set
Safety Bridging Plugs Set
EM-3330-3B
EM-3320-1A
EM-3320-1N
EM-3310-1D
EM-3310-1B
EM-3310-2A
EM-3310-3H
EM-3390-2A
EM-3390-2B
EM-3390-2C
EM-3390-3A
EM-3390-4A
CIRCUIT DIAGRAMS:
Fig-3. Connection diagram for wound-rotor induction motor for blocked-rotor test
PROCEDURE: (Part-1: shorted rotor windings)
Set up the equipment as shown in Fig-1 and Fig-2.
1. Mechanically couple the wound-rotor induction machine to magnetic powder brake
unit using a coupling. Install the coupling guard and shaft end guard. Electrically
connect the brake controller to the magnetic powder brake using the RS232 cable.
Before using the brake controller and magnetic powder brake unit, you must first
calibrate the torque display of the brake controller to 0 kg.m by adjusting the zero adj
knob located on the rear panel of magnetic powder brake unit with power on.
Calculate the input power, output power and efficiency using the following formulas:
Input Power:
V I
Pin
1 , ll
Pout
Output Power:
Efficiency:
P
2 n (rpm ) T ( Nm )
out
60
100%
in
Table-1. Measured values with wound-rotor induction motor with shorted rotor windings
Measured
values
Torque (T, Speed
kg.m)
(n,rpm)
0.00
0.10
0.15
0.20
0.25
0.30
Voltage
(V1, V)
Current
(I1,A)
Input Power
Factor
Calculated
values
Input Power
(Pin,W)
Output Power
(Pout, W)
Efficiency
(%)
Table-2. Measured values with wound-rotor induction motor with blocked rotor test