2GIG Wireless Carbon Monoxide Alarm

INSTALL INSTRUCTIONS
TheWirelessCarbonMonoxideAlarm,partnumber2GIGCO3345isa3Vbattery
poweredwirelessdetectorintendedforusewithwirelessalarmsystems.The
detectorconsistsofanelectrochemicalcarbonmonoxidesensorassemblycoupled
toawirelesstransmitter.TheWirelessCarbonMonoxideAlarmcommunicateswith
theControlPanelandcansendalarm,tamperandbatteryconditionmessagesto
thesystemsreceiver.Toknowthemaximumnumberoftransmittersthatcanbe
supported,seethe2GIGSecuritySystemInstallGuide.
IMPORTANT: Thisdetectormustbetestedandmaintainedregularly
followingNFPA720requirements.
Thisdeviceisdesignedto
protectindividualsfromthe
acuteeffectsofcarbon
monoxideexposure.Itwillnot
fullysafeguardindividuals
withspecificmedical
conditions.Ifindoubtconsult
amedicalpractitioner.
WARNING: ThisCarbon
MonoxideAlarmis
intendedforusein
ordinaryindoor
residentialareas.Itisnot
designedtomeasure
compliancewith
OccupationalSafety&
HealthAdministration
(OSHA)commercialand
industrialstandards.

Box Contents
WirelessCarbonMonoxideAlarmwithbase
Packofscrewsandfixings
Stickersasappropriate
1CR123APanasonicbattery
TheWirelessCarbonMonoxideAlarmcontainsasounderwhichgeneratestheANSI
S3.41temporal4patterninanalarmcondition(fortemporal4pattern,seethe
followingtable).Inalarm,amessageisalsosenttotheControlPanelandthe
detectorsIDisdisplayedonthescreen.Duringanalarmcondition,pressingthe
detectorshushbuttonwillsilencethesounderforfiveminutes.Themountingbase
installationissimplifiedbytheincorporationoffeaturescompatibleforboth
drywallfasteners(notsupplied)andothermethods.
TricoloredLED(green,yellow,red)andasounderonthedetectorprovidelocal
visualandaudibleindicationofthedetectorsstatusaslistedinthefollowingtable.
DuringinitialpoweruptheLEDblinksalternatelygreen,yellowthenred.Ittakes
about60secondsforthedetectorsCOsensortostabilize.
Afterpoweruphascompletedandthedetectorisfunctioningnormally,thegreen
LEDblinksonceevery12seconds.

Detector Trouble
Whenthesensorsupervisionisintroublecondition,theyellowLEDblinksonce
everysixsecondsandthereisachirpevery45seconds.After12hoursthepanel
willdisplayalossofsupervisionmessage.

Detector End-of-Life
Whenthedetectorhasreachedtheendofitslife,theyellowLEDblinksonceevery
23secondsandthereisachirpevery45seconds.After12hoursthepanelwill
displayalossofsupervisionmessage.ThisindicatesthattheCOsensorinsidethe
detectorhaspassedtheendofitslifeandthedetectormustbereplaced.The
detectorlifespanisfiveyearsfromthedateofmanufacture.

Unauthorizedchangesormodificationscouldvoidtheusersauthority
tooperatetheequipment.
Status

LEDs

Sounder

RadioSignaling

2GIGControl
PanelResponse

Normal(None)

Normal(None)

Alarm

Onscreenand
audibleAlarm
(usercodeto
silence)

Fault

OnscreenAlert
shown(after12
hours)Device
nameLossof
Supervision
OnscreenAlert
shownDevice
name
BatteryLow

(doesnotpulse
thesounderand
LEDconcurrently)

Normal

Alarm/Test

Detector
Trouble

LowBattery

Greenflash
every12
seconds
Redflashevery
12seconds

Off

ANSIS3.41
temporal4
(pressbuttonto
hushfor5
minutes)
Yellowflash
One100ms
every6
chirpevery45
seconds
seconds

Yellowflash
every12
seconds

One100ms
chirpevery45
seconds(press
buttontohush
for12hours)
DetectorEnd Yellowflash
One100ms
ofLife
every23
chirpevery45
seconds
seconds
PowerUp
Green,Yellow, One100ms
Redflash
chirpatendof
sequence
powerup
every12
sequence
seconds
Off
Tamper
Green,Yellow,
Redflash
sequence
every12
seconds

LowBattery

None

Normal(None)

None

Normal(None)

Tamper

OnscreenAlert
shown
Devicename
Tamper

Inserting and Replacing Batteries


1
2
3

4
5

Removethedetectorfromitsmountingbasebytwistingthedetector
counterclockwise.Removeanddisposeofthebatteryaccordingtolocal
regulations.
Toensureproperpowerdownsequence,waitaminimumof20secondsbefore
installingnewbattery.
Installanew3voltCR123APanasonicLithiumbattery(availablefromyour
Panasonicdealer)inthebatterycompartment.Followthepolaritydiagram
insidethecompartment!Ifthebatteryisincorrectlyinserted,removegently
withanonconductivetoolandcorrectlyreinsert.
Reinstallontothemountingbasebyturningthedetectorclockwise.
AfterthepowerupsequencethegreenLEDshouldblinkaboutonceevery12
secondstoindicatenormaloperation.Ifthebatteryisnotinstalledcorrectly,
thedetectorwillnotoperateandthebatterymaybedamaged.Ifthedetector
doesnotpowerup,checkforafullychargedbattery.

Low Battery Detection


TheWirelessCarbonMonoxideAlarmispoweredbyasingle3voltCR123A
PanasonicLithiumbattery.Thedetectorregularlychecksforalowbattery.Ifalow
batteryisdetected,thetransmittersendsalowbatterymessagetotheControl
Panel,whichdisplaysthedetectorsIDatlowbattery.Inaddition,theyellowLEDof
thedetectorwillblinkevery12seconds.Thedetectorssounderwillchirpevery45
seconds(yellowLEDcontinuestoblink)untilthebatteryisreplaced.Pressingthe
hushbuttonsilencesthechirpsfor12hours,ifnoothertroubleconditionsexist.
Replacethebatterywhenthechirpsbegin.Besuretoreplacethebatterywitha
freshone.

Constantexposurestohighorlowtemperaturesorhighhumiditymay
reducebatterylife!
2013 2GIG by Linear Corporation. All Rights Reserved. 1

PROGRAMMING
Thefollowingstepsareguidelinesforprogramming(learning)theWirelessCarbon
MonoxideAlarm(2GIGCO3345)intothe2GIGControlPanel.Scrollbetween
op onsusingtheandarrows.Movetothepreviousornextpromptby
pressingtheandarrows.
1 SelectRFsensor#(01to48).AssigntheWirelessCarbonMonoxideAlarmtoa
newzone.
2 SelectRFsensortype.
(14)24hourCarbonMonoxideAlarm
3 SelectRFequipmenttype.
4 SelectRFsensorequipmentcode.Enter0859(inCanada)or0860(inU.S.A.)for
the2GIGCO3345Alarm.
5 EnterRFsensorserialnumber(7digits).
ManualEntry:Typeinthelast7digitsoftheTXIDthatisfoundoutsidethebox
oronthe
bottomoftheheadunitbyremovingthebase.
AutoEntry:WiththepanelinLearninmode(pressShiftthenLearn)causea
tamperonthealarmbytwistingthebaseunitcounterclockwiseandremoving
it.ThecorrectTXIDshouldappear.AcceptthecorrectTXIDbypressingok.
Remembertopressthearrowtocontinuethroughthesystemconfiguration
prompts.
6 SelectRFsensorequipmentage.
(0)new(productisnew)
(1)existing(productalreadyexists)
7 SelectRFsensorloopnumber(1).
8 SelectRFsensor1dialerdelay.
(0)disabled(thereshouldneverbeadialerdelayonthistypeofalarm)
9 ConstructRFsensordescriptor.PressInsertthenpressanynumberbetween
002and255toaddaword.Forexample,ifyouwantedtonamethisalarmas
CarbonMonoxideAlarm,pressInsertthenpress032forCARBON
MONOXIDE.PressInsertthenpress005forALARM.
10 SelectRFsensorreports(0to1).
(1)enabled(sensorreportstothecentralstation)
11 SelectRFsensorsupervised(0to1).
(1)enabled(sensorreportslossofsupervisionorlowbattery)
12 SelectRFsensorchime(0to13).
(0)disabled(panelwillnotchimewhensensorisactivated)
13 Toprogramanothersensor,clicknext.
14 Toexitprogramming,clickskipthenendandexit.Uponexit,thepaneltakesa
fewsecondstoreset.

NOTIdealLocations:
Directlyaboveasink,cooker,stoveoroven
Donotlocatedetectorwithin5feet(1.5m)ofanycookingappliance
Nexttoadoororwindowthatwouldbeaffectedbydrafts,.extractorfanorair
vent
Outside
Donotinstallinanyenvironmentthatdoesnotcomplywiththedetectors
environmentalspecifications
Inorbelowacupboard
Whereairflowwouldbeobstructedbycurtainsorfurniture
Wheredirtordustcouldcollectandblockthesensor
Whereitcouldbeknocked,damaged,orinadvertentlyremoved

To Mount the Detector


1

Seethefigurebelowandinstallthemountingbaseontheceilingoronthewall
(iflocalordinancespermit)usingscrewlocationsasrequired.Usethetwo
screwsandanchorsprovided.Maneuverthebasesothescrewsareatthe
elbowofthescrewslotsandsecure.
2 Fitthedetectorinsidethebasebyaligningitoverthebaseasshown
(detectorsalignmentnotchshouldbeslightlyoffsetfrommountingbase
tamperreleasetab).
3 Testthedetectoraftercompletingtheinstallation(seeTestingtheDetector).
Seethe2GIGSecuritySystemInstallGuideforadditionalinformation
concerningtheuseofwirelessdevices.
WARNING: DONOTattachthedetectortoremovableceilingpanels.
4 Twowarninglabelsareprovidedinthedetectorbox.PlaceonenexttotheCO
detectorandanotherneartoasourceoffreshairwheremembersofthe
householdwillgatherifalarmsignalsounds.

Installing and Mounting


Determinethebestlocationforthedetector,onethatprovidespropercarbon
monoxidedetection.

Proper Carbon Monoxide Detection Location


Wallmounteddetectorsshouldbepositionedatleastashighasalightswitch,and
atleastsixinches(15cm)fromtheceiling.Inaceilinglocation,thedetectorshould
beatleast12inches(30cm)fromanywall.
IdealLocations:
Within10feet(3m)ofasleepingarea
Insidethebedroomifitcontainsafuelburningappliance
Oneveryfloorofthebuilding
Ideally,installinanyroomthatcontainsafuelburningappliance
Iftheapplianceortheroomisnotnormallyused,suchastheboilerroom,the
detectorshouldbeplacedjustoutsidetheroomsothealarmcanbeheard
moreeasily

WARNING:
Airbornedustparticlescanenterthedetector.2GIGTechnologies
recommendstheremovalofdetectorsbeforebeginningconstructionor
anyotherdustproducingactivity.Carbonmonoxidedetectorsarenotto
beusedwithdetectorguardsunlessthecombinationhasbeenevaluated
andfoundsuitableforthatpurpose.

Tamper Protection
AtamperalertisdisplayedattheControlPanelifthebuiltintamperswitchis
removedfromitsmountingbase.TheWirelessCarbonMonoxideAlarmincludesa
tamperresistantfeaturethatpreventsremovalfromthemountingbasewithoutthe
useofatool.Toengagethetamperresistantfeature,cutthesmallplastictab
locatedonthemountingbaseandtheninstallthedetector.
Toremovethedetectorfromthebaseonceithasbeenmadetamperresistant,use
appropriatescrewdrivertodepressthesquaretamperreleasetablocatedonthe
skirtofthemountingbaseandturnthedetectorcounterclockwise.

Testing the Detector


Beforetesting,notifythecentralmonitoringstationthatthesecuritysystemis
undergoingtestsandmaintenance.Thisactionpreventsunwantedalarms.
TestingthedetectoractivatesanalarmandsendsanalarmsignaltotheControl
Panel.Also,thetestfunctioncannotbeusedifthedetectorhasatroubleorendof
lifecondition.
Detectorsmustbetestedafterinstallationandfollowingperiodicmaintenance.

To Test Detector Operation

ThisWirelessCarbonMonoxideAlarmshouldonlybecommissioned
andinstalledbyacompetentengineer.
2 2013 2GIG by Linear Corporation. All Rights Reserved.

Totestthedetectorssounder,LEDs,andtransmitter,dothefollowing:
1 Thetestbuttonislocatedonthedetectorhousing.
2 Pushandholdthetestbuttonforaminimumof5seconds.TheControlPanel
willtriggerandthedetectorwillgointoalarm.Thesounderbeginsthe
temporal4patternandtheredLEDblinks.ThesecuritysystemsControlPanel
displaysthedetectorsnameinalarm.

Carbon Monoxide Gas and its Detection

Replacing the Detector

Thiscarbonmonoxidedetectorisdesignedforindooruseonly.Donotexposeto
rainormoisture.Donotknockordropthedetector.Donotopenortamperwith
thedetectorasthiscouldcausemalfunction.Thedetectorwillnotprotectagainst
theriskofcarbonmonoxidepoisoningifnotproperlyinstalled.
WARNING: Thisdevicewillonlyindicatethepresenceofcarbonmonoxide
gasatthesensor.Carbonmonoxidegasmaybepresentinotherareas.
Thiscarbonmonoxidealarmingdeviceisdesignedtodetectcarbonmonoxidegas
fromANYsourceofcombustion.ItisNOTdesignedtodetectsmoke,orothergases
unlesstheproducthasbeeninvestigatedanddeterminedtocomplywithapplicable
requirements.
Thisdeviceshouldnotbeinstalledasasubstituteforproperinstallation,use,and
maintenanceoffuelburningappliances,includingappropriateventilationand
exhaustsystems.
Carbonmonoxidegasisahighlypoisonousgaswhichisreleasedwhenfuelsare
burned.Itisinvisible,hasnosmellandisthereforeimpossibletodetectwiththe
humansenses.Undernormalconditionsinaroomwherefuelburningappliances
arewellmaintainedandcorrectlyventilated,theamountofcarbonmonoxide
releasedintotheroombyappliancesshouldnotbedangerous.

Thisdetectorismanufacturedwithalonglifecarbonmonoxidesensor.Overtime
thesensorwilllosesensitivity,andwillneedtobereplacedwithanewcarbon
monoxidedetector.Thedetectorslifespanis5yearsfromthedateofmanufacture.
NOTE: Whenthedetectorisremovedfromitsbase,aTampermessageis
senttothecentralmonitoringstation.Thedetectoralsocausesatrouble
conditionwhenithasreachedtheendofitslife.Ifthisoccurs,itistimeto
replacethedetector.
Beforereplacingthedetector,notifythecentralmonitoringstationthat
maintenanceisbeingperformedandthatthesystemwillbetemporarilyoutof
service.FromtheControlPanel,disablethezoneorsystemundergoing
maintenancetopreventanyunwantedalarms.Disposeofthedetectorin
accordancewithanylocalregulations.
IMPORTANT: TheReplacementDatethatappearsonthedeviceisthedate
beyondwhichthedevicemaynolongerdetectcarbonmonoxide
accuratelyandshouldbeimmediatelyreplaced.
Theinstallation,operationtestingandmaintenanceoftheWirelessCarbon
MonoxideAlarmisdifferentthansmokedetectors.PerNFPA720section5.3.7.2the
detectorshallnotbeconnectedtoazonethatsignalsafirecondition(i.e.smoke
detector/alarmzones).Therefore,theWirelessCarbonMonoxideAlarmmustbe
programmedasanonfirezone.Seestep2underProgrammingforthecorrect
CarbonMonoxidezonetypetoprogram.

Conditions Resulting in Dangerous CO


Situations
1

Excessivespillageorreverseventingoffuelburningappliancescausedby:
outdoorambientconditions,suchaswinddirectionand/orvelocity,
includinghighgustsofwind,andinsufficientdraftintheventpipes
negativepressuredifferentialresultingfromtheuseofexhaustfans
simultaneousoperationofseveralfuelburningappliancescompetingfor
limitedinternalair
looseventpipeconnectionsfromfuelfedappliances,
obstructions,orunconventionalventpipedesignsthatcanamplifythe
abovesituations
poorlydesignedormaintainedchimneysand/orvents
2 Extendedoperationofunventedfuelburningdevices(range,oven,replace,
etc.)
3 Temperatureinversionsthattrapexhaustgasesneartheground
4 Caridlinginanopenorclosedattachedgarage,ornearahome
IfyouhavebeenexposedtoCarbonMonoxidePoisoning,youmaybesuffering
fromvarioussymptoms(discussthesesymptomswithallofthemembersofyour
household):

Mild Exposure

Headache,runningnose,soreeyes(oftendescribedasflulikesymptoms)

Medium Exposure

Dizziness,drowsiness,vomiting

Extreme Exposure
Unconsciousness,braindamage,death
ManyreportedcasesofreportedCarbonMonoxidePoisoningindicatethatwhile
victimsareawaretheyarenotwell,theybecomesodisorientedthattheyare
unabletosavethemselvesbyeitherexitingthebuildingorcallingforassistance.
Youngchildrenandpetsmaybethefirsttobeaffected.
WARNING: Individualswithmedicalproblemsshouldconsiderusing
warningdeviceswhichprovideaudibleandvisualsignalsforcarbon
monoxideconcentrationsunder30ppm.

Actuation of this device indicates the presence of Carbon


Monoxide (CO) which can KILL YOU
Ifthealarmsignalsounds,fourbeeps:
1 Pushthehush/testbutton.
2 Immediatelymovetofreshair(outdoorsornexttoanopenwindow).
3 Checkthatallpersonswithintheareaareaccountedfor.
4 Donotreenterthepremises(ormoveawayfromtheopenwindowuntilthe
emergencyservicerespondershavearrived,thepremiseshavebeenairedout,
andyouralarmremainsinnormalcondition.
5 Callemergencyservices,thefiredepartment,or911.
6 Iftheservicesignalsounds,onechirp,thenchecktheservicesectiontotryand
correct.
7 Afterfollowingsteps16,ifyouralarmreactivateswithina24hourperiod,
repeatsteps16andcallyourlocalqualifiedtechniciantoinvestigatefor
sourcesofCOfromfuelburningequipmentandappliancesandinspectfor
properoperationofthisCOdetector.Ifproblemsareidentifiedduringthis
inspection,havetheequipmentservicedorreplacedimmediately.Noteany
combustionequipmentnotinspectedbythetechnicianandconsultthe
manufacturersinstructions,orcontactthemanufacturersdirectlyformore
informationaboutCOsafetyandthisequipment.Makesurethatmotor
vehiclesarenot,andhavenotbeen,operatinginanattachedgarageor
adjacenttotheresidence.

Specifications
PowerSource
AudibleSignal(temp4tone)
OperatingCurrent
TemperatureRange
OperatingHumidityRange
AgencyListings

One3voltCR123APanasonicLithiumbattery
85dBAmin.inalarmat10ft.(3m)
10A
40F(4.4C)to100F(37.8C)
15%to95%RelativeHumidity,noncondensing
ULStandard2075,UL2034andCSA6.1901

Regulatory Compliance
ThisdevicecomplieswithPart15oftheFCC'sRules.Operationissubjecttothe
followingtwoconditions:
1.Thisdevicemaynotcauseharmfulinterference,and
2.Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.

ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
digitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedto
providereasonableprotectionagainstharmfulinterferenceinaresidential
installation.
Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructions,maycauseharmful
interferencetoradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby
turningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe
interferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhich
thereceiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
ThisproductcomplieswithFCCradiationexposurelimitsforanuncontrolled
environment.Avoidoperatingthisproductatadistancelessthan20cmfromuser.
Caution:Anychangedormodificationsnotexpresslyapprovedbytheparty
responsibleforcompliancecouldvoidtheuser'sauthoritytooperatethis
equipment.

Limited Warranty
This2GIGTechnologiesproductiswarrantedagainstdefectsinmaterialand
workmanshipfor2years.Thiswarrantyextendsonlytowholesalecustomerswho
buydirectfrom2GIGTechnologiesorthrough2GIGTechnologiesnormal
distributionchannels.2GIGTechnologiesdoesnotwarrantthisproductto
consumers.Consumersshouldinquirefromtheirsellingdealerastothenatureof
thedealerswarranty,ifany.
Therearenoobligationsorliabilitiesonthepartof2GIGTechnologiesfor
consequentialdamagesarisingoutoforinconnectionwithuseorperformanceof
thisproductorotherindirectdamageswithrespecttolossofproperty,revenue,or
profit,orcostofremoval,installation,orreinstallation.Allimpliedwarrantiesfor
functionality,arevalidonlyuntilthewarrantyexpires.This2GIGTechnologies
Warrantyisinlieuofallotherwarrantiesexpressedorimplied.
FortechnicalsupportintheUSAandCanada:
8552GIGTECH(8552444832)
Email:techsupport@2gig.com
Internet:dealer.2gig.com
Visitwebsitefortechnicalsupporthoursofoperation
FortechnicalsupportoutsideoftheUSAandCanada:
Contactyourregionaldistributor
Visitdealer.2gig.comforalistofdistributorsinyourregion
PN:39214596Rev.B

2013 2GIG by Linear Corporation. All Rights Reserved. 3