Beruflich Dokumente
Kultur Dokumente
BE106-01
Pattern 2
Pattern 3
OPEN
OPEN
OPEN
Middle
Position
CLOSE
Middle
Position
CLOSE
TIME
Middle
Position
CLOSE
TIME
TIME
Specifications
2-Staged Open/Close Rotary type Pneumatic Actuator
6.0
New-PTFE
NCF
NGR
CFMR
1525A
6.0
PO-06T
PO-08T
PO-10T
PO-12T
15 to 150A
15 to 100A
-10C to 60C*
Solenoid Valve 2 sets,
Air Filter Regulator 1 set,
Speed Controller 1 set
Standard
Accesories
Optional
Manually
Operation
3.0
2.0
1.0
4.0
3.0
2.0
1.0
0
0
0
40
80
120
160
200 240
40
Temp (C)
6.0
4.0
Pressure (MPa)
PN-05T
PN-06T
PN-08T
PN-10T
PN-12T
80
120
160
200 240
Temp (C)
80100A
6.0
125150A
CL300 body rating
5.0
5.0
4.0
3.0
2.0
CL150 body rating
1.0
Pressure (MPa)
Code Number
Details are referred to
the selection table.
Pressure (MPa)
5.0
5.0
Pressure (MPa)
ITEMS
4065A
Applied to
Seat Materials
NTF
4.0
3.0
2.0
CL150 body rating
1.0
0
0
40
80
120
160
200 240
Temp (C)
40
80
120
160
200 240
Temp (C)
Ball
Seat
Flange Code
Painting (Body)
JIS10KRF, JIS20KRF,
ANSI CL 150, 300
Silver (excepting stainless steel)
Fluid State
Fluid Temp.
Factor
a
Factor Combination
Rank
3a
2a+b, a+2b
a+b+c, 3b,
2c+a, 2c+b
-20C to 150C
2a+c, 2b+c,
C
FPN3100NB
B
B2
B1
Rc1/4
(SHUT)
Nominal
Size
(A)
15
20
25
13
19
25
108
117
127
140
152
165
40
38
165
190
50
51
178
216
65
64
190
241
80
76
203
283
100
102
229
305
125
150
127
152
356
394
381
403
Actuator
Rc1/4
(OPEN)
H
H1
Rc1/4
B1
B2
H1
277
277
277
277
336
336
412
336
412
412
513
513
629
629
629
86
86
86
86
107
107
133
107
133
133
168
168
210
210
210
191
191
191
191
229
229
279
229
279
279
345
345
419
419
419
03
03
03
03
03
03
04
03
04
04
06
06
29
29
29
183
187
201
219
245
253
285
281
313
323
370
407
451
487
507
121
125
139
157
165
173
185
201
213
223
245
282
301
337
357
Pressure: 0.4MPa
Nominal
Size
(A)
Rank
0.2
0.4
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
15
20
25
40
50
65
80
100
125
150
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
Rank
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
PN-05T
PN-06T
PN-06T
PN-08T
PN-10T
PN-12T
Nominal
Size
(A)
15
20
25
40
50
65
80
100
125
150
FPO3100NB
B
B2
B1
Rc1/4
(EXH.)
Nominal
Size
(A)
15
20
25
40
13
19
25
38
108
117
127
165
140
152
165
190
50
51
178
216
65
64
190
241
80
76
203
283
100
102
229
305
Rc1/4
(OPEN)
H
H1
Rc1/4
Actuator
B1
B2
H1
504
504
504
621
621
770
770
959
770
959
959
275
275
275
342
342
425
425
540
425
540
540
229
229
229
279
279
345
345
419
345
419
419
209
213
227
277
285
332
362
406
372
416
448
129
133
147
177
185
207
237
256
247
266
298
Pressure: 0.4MPa
Nominal
Size
(A)
Rank
15
20
25
40
50
65
80
100
q Operation Type
PN
PO
Double Acting
Single Acting (Air to Open)
w 3=Control Valve
(2stage on-off)
e Body Material
04
07
12
13
FCD400
SCS13A
SCS14A
SCS16A
0.2
0.4
0.6
0.8
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
1.0
1.2
1.4
1.6
1.8
PO-08T
PO-10T
PO-12T
PO-12T
none
N
NB
NC
Initial
First Improvement
Second Improvement
Third Improvement
r Seat Material
NTF
NCF
NGR
CFMR
New-PTFE
PTFE reinforced with Carbon Fiber
PTFE reinforced with Glass Fiber
CF with Inner/Outer Metal Ring
Nominal
Size
(A)
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
PO-06T
[ Improvement Code
2.0
Rank
15
20
25
40
50
65
80
100
t Nominal Size
Based on
ISO 6708 and JIS B 2001.
y Actuator Code
u Connection Code
J10KRF
J20KRF
A150RF
A300RF
JIS 10KRF
JIS 20KRF
ANSI CL 150
ANSI CL 300
EXPLANATION on ACTION
Double Acting Type
(Air to Open/Air to Close)
OPEN
B
E1 SOLENOID
VALVE 1
E2 SOLENOID
VALVE 2
C SPEED CONTROLLER
E1 SOLENOID
VALVE 1
C SPEED CONTROLLER
E2 SOLENOID
VALVE 2
Middle
Position
CLOSE
TIME
OPEN
Middle
Position
CLOSE
TIME
A
Action A B When E1 is set ON, air goes to CY1. Then the valve opens to
planned middle position.
Middle
Position
CLOSE
TIME
A
Action C D When E1 is ON and E2 is set ON, air goes to CY3. Air at CY2
goes to atmosphere and the valve becomes fully open.
Middle
Position
CLOSE
TIME
A
Action E F When E1 is ON and E2 is set OFF, air goes to CY2. Air at CY3
goes to atmosphere and the valve closes to planned middle position.
Middle
Position
CLOSE
A
Action G H When E1 and E2 is set OFF, air at CY1 goes to atmosphere.
Then the valve becomes fully close.
TIME
CAUTION
Specifications and performance figures of products contained in this catalog are on the design calculations, in-house tests,
actual records of product application, and the official standards and specifications. They are presented as the user guide on
the use of product concerned under general service conditions. Users intending to use the product under a special condition
are required to receive engineering advice from this company in advance or to make their own studies and evaluation to verify
performance on their own responsibility. This company shall not be liable for any damages, material or human, that may arise
without following this procedure. In as much as full care was taken in editing this catalog, users are kindly requested to make
contact with this company for any questions or discrepancies found. This catalog is subject to change without notice for the
purpose of correcting error, supplementing or improving insufficient content, updating the content to the improved product
performance, design change, discontinuation of product and other reasons. Revised version automatically invalidates catalogs
issued prior to the current version. When you select products for possible order placement, please check the issuance code
number on the back of your catalog and verify with this company that it is the latest version.
WARNING
CAUTION
There are some instructions for use of diaphragm valve because of a constructional characteristic. When valve is delivered, the
leaflet related to instruction on Safely is bundled. Please read this instructions thoroughly before beginning of use and handling
to use your product safely and stably for a prolonged life.
http://www.ndv.co.jp
12. 06. HA
12. 06.