Sie sind auf Seite 1von 5

Introduction

This document shows various UCS failure scenarios and method to test them. These
tests are good to check for correct UCS system behavior in case of a failure. A UCS
system consists of one or two UCS 6100 series switches or fabric interconnects. A
UCS system with two fabric interconnects is typically deployed in active-active pair
that supports failover. UCS 2100 fabric extender enables the UCS 6100 fabric
interconnect to provide all access-layer switching needs for the connected servers.
This traffic is then switched to its required destination by the fabric interconnect and
no switching, whatsoever, is done by the fabric extender. This document shows how
to test the following failure scenarios using the UCS Manager CLI:

Fabric Interconnect failure

UCS Blade failure

Server Port failure

Uplink Port failure


Testing Fabric Interconnect failure
The method here is to reboot one FI switch, preferably the subordinate fabric
interconnect switch. The expected result is to check the "show cluster state"
command will show the primary fabric interconnect "UP" and the subordinate fabric
interconnect "DOWN". The fabric interconnect cluster will show "NOT READY".
Sample Test
On Fabric Interconnect A (Primary):
UCS1-FA-A# show cluster state
Cluster Id: 0x603bca7e0b7311e1-0x9987547fee1fd575
A: UP, PRIMARY
B: UP, SUBORDINATE
HA READY
On Fabric Interconnect B (Subordinate):
UCS1-FA-B(local-mgmt)# reboot
The switch will be rebooted. Are you sure? (yes/no):yes
Read from remote host 10.134.166.89: Connection reset by peer
Connection to 10.134.166.89 closed.
Verify on the Primary Fabric Interconnect:
UCS1-FA-A# show cluster state
Cluster Id: 0x603bca7e0b7311e1-0x9987547fee1fd575
A: UP, PRIMARY

B: DOWN, INAPPLICABLE
HA NOT READY
Peer Fabric Interconnect is down
Testing UCS Blade failure
This method requires reboot of a UCS blade server. The expected result is that the
Overall Status coloumn in the "show server status" command will show "Power Off"
while the blade is rebooting.
Sample Test
[UCS1-80 ~]$ reboot
Verify on the Primary Fabric Interconnect:
UCS1-FA-A# show server status
Server Slot Status

Availability Overall Status

Discovery

------- --------------------------------- ------------ --------------------- --------<--output omitted-->


10/1

Equipped

Unavailable Ok

Complete

10/2

Equipped

Unavailable Ok

Complete

10/3

Equipped

Unavailable Ok

Complete

10/4

Equipped

Unavailable Ok

Complete

10/5

Equipped

Unavailable Ok

Complete

10/6

Equipped

Unavailable Ok

Complete

10/7

Equipped

Unavailable Ok

Complete

10/8

Equipped

Unavailable Power Off

Complete

Testing Server Port failure


This method requires to disable a server port (interface); e.g. server port 1/9 in fabric
interconnect B. The expected result is that the server's "show interface" command in
the fabric will show the port's Admin State "Disabled" and Oper State "Failed".
Sample Test
UCS1-FA-A# scope eth-server
UCS1-FA-A /eth-server # scope fabric b
UCS1-FA-A /eth-server/fabric # show interface
Interface:
Slot Id
Reason

Port Id

Admin State Oper State

Lic State

Grace Prd

State

---------- ---------- ----------- ---------------- -------------------- --------------- -----------1

Enabled

Up

License Ok

10

Enabled

Up

License Ok

11

Enabled

Up

License Ok

<--output omitted-->
1

Enabled

Up

License Ok

Enabled

Up

License Ok

Enabled

Up

License Ok

Enabled

Up

License Ok

UCS1-FA-A /eth-server/fabric # enter interface 1 9


UCS1-FA-A /eth-server/fabric/interface # disable
UCS1-FA-A /eth-server/fabric/interface # commit-buffer
UCS1-FA-A /eth-server/fabric/interface # exit
To Verify:
UCS1-FA-A /eth-server/fabric # show interface
Interface:
Slot Id Port Id
Reason

Admin State Oper State

Lic State

Grace Prd

State

---------- ---------- ----------- ---------------- -------------------- --------------- -----------1

1 Enabled

Up

License Ok

10 Enabled

Up

License Ok

11 Enabled

Up

License Ok

<--output omitted-->
1

6 Enabled

Up

License Ok

7 Enabled

Up

License Ok

8 Enabled

Up

License Ok

1
change

9 Disabled

Failed

Unknown

0 Admin config

UCS1-FA-A / eth-server # exit


Testing Uplink Port failure

This method requires to disable services on an uplink port, e.g. Uplink Port 1/39 on
Fabric B. The expected result is that the fabric's uplink "show interface" command will
show the port's Admin State "Disabled" and Oper State "Admin Down".
Sample Test
UCS1-FA-A# scope eth-uplink
UCS1-FA-A /eth-uplink # scope fabric b
UCS1-FA-A /eth-uplink/fabric # show interface
Interface:
Slot Id
Port Id
State Reason

Admin State Oper State

Lic State

Grace Period

---------- ---------- ----------- ---------------- -------------------- --------------- -----------1


36
Disabled
Administratively down

Admin Down

Unknown

1
40
Disabled
Administratively down

Admin Down

Unknown

Member Port:
Port-channel Slot Port Oper State
State
Grace Period

State Reason

Lic

------------ ----- ----- --------------- ----------------------------------- -------------------- -----------1


Ok

1
0

35

Up

License

1
Ok

1
0

39

Up

License

2
1
Unknown

33

Sfp Not Present Unknown


0

2
1
Unknown

37

Sfp Not Present Unknown


0

UCS1-FA-A /eth-uplink/fabric # enter interface 1 39


UCS1-FA-A /eth-uplink/fabric/interface* # disable
UCS1-FA-A /eth-uplink/fabric/interface* # commit-buffer
UCS1-FA-A /eth-uplink/fabric/interface # exit
To verify:
UCS1-FA-A /eth-uplink/fabric # show interface
Interface:

Slot Id
Port Id
State Reason

Admin State Oper State

Lic State

Grace Period

---------- ---------- ----------- ---------------- -------------------- --------------- -----------1


36
Disabled
Administratively down

Admin Down

Unknown

1
39
Disabled
Administratively down

Admin Down

Unknown

1
40
Disabled
Administratively down

Admin Down

Unknown

Member Port:
Port-channel Slot Port Oper State
State
Grace Period

State Reason

Lic

------------ ----- ----- --------------- ----------------------------------- -------------------- -----------1


Ok

1
0

35

Up

2
1
Unknown

33

Sfp Not Present Unknown


0

2
1
Unknown

37

Sfp Not Present Unknown


0

UCS1-FA-A /eth-uplink/fabric # exit