1. Automatic self-closing rolling shutter which completely encloses the top of each escalator
a) Spray nozzle method
b) Partial enclosure
c) Rolling shutter method
d) Fire-stopping concealed spaces
2. Kiosk designed to provide an effective barrier to the spread of smoke from floor to floor
a) Spray nozzle method
b) Partial enclosure
c) Rolling shutter method
d) Fire-stopping concealed spaces
3. Concealed space in which exposed materials with flame-spread rating greater than class A are fire-stopped
a) Spray nozzle method
b) Partial enclosure
c) Rolling shutter method
d) Fire-stopping concealed spaces
4. What is the maximum travel distance for places of assembly if not protected by automatic fire suppression?
a) 26 mtrs.
b) 36 mtrs.
c) 46 mtrs.
d) 56 mtrs.
5. What is the maximum travel distance for places of assembly if protected by automatic fire suppression (in meters)?
a) 41
b) 51
c) 61
d) 71
6. For multiple seating in places of assembly, rows of seats between aisles shall have this maximum number of seats.
a) 7
b) 9
c) 11
d) 14
7. Minimum back to back spacing for seats in places of assembly.
a) 0.63 mtrs
b) 0.73 mtrs
c) 0.83 mtrs
d) 0.93 mtrs.
8. Aisle width for more than 60 seats in multiple seating for places of assembly.
a) 0.91-1.00 mtrs
b) 0.81-1.00 mtrs.
c) 0.91-1.10 mtrs.
d) 0.81-1.10 mtrs.
9. Aisle width for less than 60 seats in multiple seating for places of assembly.
a) 0.66 mtrs.
b) 0.76 mtrs.
c) 0.86 mtrs.
d) 0.96 mtrs.

10. Minimum occupant load for concentrated use without fixed seats in places of assembly such as auditorium, church,
dance floor, lodge room
a) 0.55 sqm/person
b) 0.65 sqm/person
c) 0.75 sqm/person
d) 0.85 sqm/person
11. Minimum occupant load for less concentrated use in places of assembly such as conference room, dining room,
exhibit room, gymnasium
a) 1.40 sqm/person
b) 2.40 sqm/person
c) 3.40 sqm/person
d) 4.40 sqm/person
12. Minimum occupant load for standing room or waiting space in places of assembly.
a) 0.18 sqm/person
b) 0.28 sqm/person
c) 0.38 sqm/person
d) 0.48 sqm/person
13. Every room or space with a capacity of over 50 persons or over 93 sqm in area shall have at least how many
doorways providing access to separate exits.
a) 1
b) 2
c) 3
d) 4
14. For educational occupancies, minimum occupant load for classrooms.
a) 0.80 sqm/person
b) 1.80 sqm/person
c) 2.80 sqm/person
d) 3.80 sqm/person
15. For educational occupancies, minimum occupant load for shops, laboratories, and vocational rooms.
a) 1.40 sqm/person
b) 2.40 sqm/person
c) 3.40 sqm/person
d) 4.40 sqm/person
16. For educational occupancies, minimum occupant load for dry nurseries with sleeping facilities.
a) 1.25 sqm/person
b) 2.25 sqm/person
c) 3.25 sqm/person
d) 4.25 sqm/person
17. Minimum occupant load for residential occupancies except for single and 2-family dwellings.
a) 15.60 sqm/person
b) 16.60 sqm/person
c) 17.60 sqm/person
d) 18.60 sqm/person
18. Minimum occupant load for business occupancies as well as industrial occupancies
a) 6.3 sqm/person
b) 7.3 sqm/person
c) 8.3 sqm/person
d) 9.3 sqm/person

19. Buildings over this height shall be provided throughout with automatic sprinkler protection.
a) 12 mtrs.
b) 15 mtrs.
c) 18 mtrs.
d) 21 mtrs.
20. A fire line system with a constant water supply and installed for the use of the Fire Service and the occupants of the
building
a) Dry standpipe
b) Combination standpipe
c) Wet standpipe
d) Fire assembly
21. A fire line system without a constant water supply, is equipped with a fire service inlet and outlet connections and
installed exclusively for the use of the Fire Service
a) Dry standpipe
b) Combination standpipe
c) Wet standpipe
d) Fire assembly
22. An auxiliary fire line system with a constant water supply installed primarily for emergency fire use by the occupant
of the building
a) Dry standpipe
b) Combination standpipe
c) Wet standpipe
d) Fire assembly
23. A hose connection at grade or street level for use by the Fire Service only
a) Siamese twin
b) Fire department house connection
c) Sprinkler system
d) Fire hose reel
24. A device that contains within it chemicals, fluids, or gases for extinguishing fires, the means for application of its
contents for that purpose, and is capable of being readily moved from place to place
a) Fire hose reel
b) Fire sprinkler
c) Fire extinguisher
d) Smoke control
25. Not a prohibited act for care of fire extinguisher.
a) Servicing portable fire extinguishers
b) Removal of inspection tags
c) Selling substandard extinguishers
d) Refilling a discharged extinguisher with another agent