Sie sind auf Seite 1von 23

Software Biomedis Biomedis M Air User Guide

Software Biomedis M Air


User Guide
Study it before usage!

You are happily welcomed as a user of software Biomedis M Air.


Please, inform us about any mistake or fault which faced you during usage of the
software! Doing it, you contribute to improvement of the software.

Contact information:
e-mail: info@biomedis.ru
tel.: +7(495) 646 8826
skype: support.biomedis

Ltd. RPC BIOMEDIS

Software Biomedis Biomedis M Air User Guide

Content
1. Function of software..
2. Requirements to equipment..
3. Installation and launch of software...
4. Work with program
4.1 Definitions and programs interface
4.2 Creation, selection and deletion of profile
4.3 Creation, deletion and editing of Complex
4.4 Connection of device with computer, download into device, upload from
device......

Software Biomedis Biomedis M Air User Guide

1. Function of software
The software Biomedis M Air is indicated for creation and editing of treating
complexes and programs, download of them into the physiotherapeutic device for
application of bioresonance therapy and anti-parasitic correction of environment
Biomedis M.
2. Requirements to equipment
For stable work of Biomedis M Air, your equipment should meet the following
minimum criteria:
System Windows XP/Vista/7
512 Mb of operative memory
Monitor with resolution of 800x600 and over
Installed Microsoft.NET Framework 4.

3. Installation and launch of software


Download Microsoft.Net Framework 4 (if older version has been installed)!
Launch the file Biomedis M Air.exe in order to install the program on your
computer!
Select the path to install the software!
Launch the software Biomedis M Air! To do it, click the icon Start,
select Biomedis M Air on the list of the programs, clicking the right
mouse button, select run as administrator! So, the program window will
appear.

Software Biomedis Biomedis M Air User Guide

4. Work with program


4.1 Definitions and programs interface
Profile is users name. Several persons may use the software. The profile contains
all individual complexes of the selected user.
Complex is consecutive set of programs.
Program is consecutive set of frequencies. The software contains list of programs
(base of program) which cant be changed.
Left side of interface: window Base of programs is list of programs which may
be classified, depending on categories, and search for names; window Information
about program reflects frequencies included in the selected program.
Right side of interface: indicator of turning on the device, list of profiles, list of
complexes included in the selected profile, list of programs included in the selected
complex. Window Time for frequency allows changing duration of impact
exercised by one frequency, thus, changing duration of program and complex.
------------------------- - - - - - -- - -- - - - - - - - - - - - - - :
Categories
Therapeutic
Search

Base of programs

Software Biomedis Biomedis M Air User Guide

7 7 chakras
Acupunctur Acupuncture neurology
Acupuctur Acupuncture thyroid gland
Allergology
, Anatomy, physiology and histology
Vertebrology
Gastroenterology
Hematology and immunology
Gynecology and obstetrics
Headaches
Dermatology and cosmetology
Infectious diseases
- Cardiology and cardiovascular
diseases
Lymphology
ENT
Mammology
Neurology
, General energy, vitalization
Oncology
Ophthalmology

Software Biomedis Biomedis M Air User Guide

Proctology
Psychology and psychiatry
Pulmonology

Information about program


Profile
Duration
Generation of files
. Duration for frequency in sec.
Complex
Duration
Program
Duration
----------------------- - - - - - - - -- - -- - - - -- - - - - - - - -

4.2 Creation, selection and deletion of profile


After program has been opened, lists of profiles, complexes and programs reflect
all profiles saved on PC, complexes included in the composition of the selected
profile, and programs included in the composition of the selected complex. If these
fields are blank, there are no saved profiles on PC.

Software Biomedis Biomedis M Air User Guide

Click the button + in the field of work with profiles to create a new profile!
The following line will appear:
n

Profile

0 sec.

------------------------- - - - - - -- - -- - - - - - - - - - - - - - :
Categories
Therapeutic
Search

Base of programs
7 7 chakras
Acupunctur Acupuncture neurology
Acupuctur Acupuncture thyroid gland
Allergology
, Anatomy, physiology and histology
Vertebrology
Gastroenterology
Hematology and immunology

Software Biomedis Biomedis M Air User Guide

Gynecology and obstetrics


Headaches
Dermatology and cosmetology
Infectious diseases
- Cardiology and cardiovascular
diseases
Lymphology
ENT
Mammology
Neurology
, General energy, vitalization
Oncology
Ophthalmology
Proctology
Psychology and psychiatry
Pulmonology

Information about program


Profile
Duration
0 . 0 sec.

Software Biomedis Biomedis M Air User Guide

. Duration for frequency in sec.


Complex
Duration
Program
Duration
----------------------- - - - - - - - -- - -- - - - -- - - - - - - - -

Activate the box Profile through double mouse click! Enter needed name of
profile instead of the word Profile! Click any other box to save the name of the
profile!
Select needed profile through mouse click (it will become colored) and click the
button x in order to delete the profile!
Select needed profile on the list of profiles through mouse click and produce
needed changes in order to change the existing profile!
4.3 Creation, deletion and editing of Complex
Select needed profile through mouse click! Click the button + in the field of
work with complexes in order to create a new complex!
The following line will appear:
n

Complex 1

0 sec.

Software Biomedis Biomedis M Air User Guide

------------------------- - - - - - -- - -- - - - - - - - - - - - - - :
Categories
Therapeutic
Search

Base of programs
7 7 chakras
Acupunctur Acupuncture neurology
Acupuctur Acupuncture thyroid gland
Allergology
, Anatomy, physiology and histology
Vertebrology
Gastroenterology
Hematology and immunology
Gynecology and obstetrics
Headaches
Dermatology and cosmetology
Infectious diseases

Software Biomedis Biomedis M Air User Guide

- Cardiology and cardiovascular


diseases
Lymphology
ENT
Mammology
Neurology
, General energy, vitalization
Oncology
Ophthalmology
Proctology
Psychology and psychiatry
Pulmonology

Information about program


Profile
Nick
Duration

Software Biomedis Biomedis M Air User Guide

0 . 0 sec.
. Duration for frequency in sec.
Complex
1 Complex 1
Duration
0 . 0 sec.
Program
Duration
----------------------- - - - - - - - -- - -- - - - -- - - - - - - - -

Activate the field Complex through double mouse click and enter needed name
instead of the word Complex 1! Click any other field in order to save the name!
Select needed complex through mouse click (it will be colored) and click the
button x in order to delete the complex!
Select needed complex through mouse click and produce needed changes in order
to change the existing complex!
Select needed complex to add a program into the complex! The selected complex
will be colored. If the complex has been created earlier, programs included in the
complex will be enumerated in the list of programs. The list will be empty, if the
complex has been created again. Select category of programs and select program
from the list in the window Base of programs through double left mouse click in
order to add the program to the selected complex! Enter letters or word in the

Software Biomedis Biomedis M Air User Guide

search box for fast finding of the needed program by its name! Only the programs
which have corresponding combination of letters or word will be displayed on the
list of programs. After change of programs category, enter letters or word into
search box again!
After needed program will have been selected, the new line with the name of the
chosen program and its duration will appear in the field of work with programs:
n

Name of selected program m sec.

-------------------------- ----- ---- :


Categories
Set of programs
Search
acti
Base of programs
- Set of programs of EM-therapy
Active protection

Information about program


Active protection

Software Biomedis Biomedis M Air User Guide

Nick
Duration
1 . 10 . 1 min. 10 sec.
Generation of files
. Duration for frequency in sec.
Complex
Morning
Duration
1 . 10 . 1 min. 10 sec.
Program
Active protection
Duration
1 . 10 . 1 min. 10 sec.
- - - - - - - - - - - - - - - - - - - - - - --- - - - -- - - - - - - - -- - - - - - - - - Select program on the list of programs in order to delete it from the complex! The
selected program will be colored. Click the button x!
Programs, composing complexes, and complexes, composing profile, may be
sorted by order with the help of the arrows

Software Biomedis Biomedis M Air User Guide

Use the buttons Program down and Program up in order to move programs
inside of complex!
-------------------------- ----- ---- :
Categories
Set of programs
Search
circula
Base of programs
- Set of programs of EM-therapy
-1 Circulation-1

Information about program


-1 Circulation-1
Profile
Nick
Duration
2 . 20 . 2 min. 20 sec.
Generation of files
. Duration for frequency in sec.

Software Biomedis Biomedis M Air User Guide

Complex
Morning
Duration
2 . 20 . 2 min. 20 sec.
Program
Active protection
-1 Circulation-1
Center of happiness
Duration
1 . 10 . 1 min. 10 sec.
1 . 0 . 1 min. 10 sec.
10 . 10 sec.
- - - - - - - - - - - - - - - - - - - - - - --- - - - -- - - - - - - - -- - - - - - - - - -

Total duration of complex is calculated with consideration of duration for every


frequency, indicated in the window Duration for frequency. In case of changing
parameter in the window Duration for frequency, duration of complex is
changed automatically. It is possible to set separated duration for frequency for
each complex.
------------------

Software Biomedis Biomedis M Air User Guide

--------- ----- ---- :


Categories
Set of programs
Search
circula
Base of programs
- Set of programs of EM-therapy
-1 Circulation-1

Information about program


Active protection
Profile
Nick
Duration
7 . 0 . 7 min. 0 sec.
Generation of files
. Duration for frequency in sec.
Complex
Morning

Software Biomedis Biomedis M Air User Guide

Duration
7 . 0 . 7 min. 0 sec.
Program
Active protection
Center of happiness
-1 Circulation-1

Duration
3 . 30 . 3 min. 30 sec.
30 . 30 sec.
3. 0 . 3 min. 0 sec.
- - - - - - - - - - - - - - - - - - - - - - --- - - - -- - - - - - - - -- - - - - - - - - -

After you will have finished forming complexes in profile, select profile and click
the button Generation of files! Indicator of files generation will appear.
-------------------------- ----- ---- :
Categories
Set of programs

Software Biomedis Biomedis M Air User Guide

Search
circula
Base of programs
- Set of programs of EM-therapy
-1 Circulation-1

Information about program


Active protection

: Complex: Morning
: Program: Active protection

Profile
Nick
Duration
7 . 0 . 7 min. 0 sec.
Generation of files
. Duration for frequency in sec.
Complex
Morning

Software Biomedis Biomedis M Air User Guide

Duration
7 . 0 . 7 min. 0 sec.
Program
Active protection
Center of happiness
-1 Circulation-1

Duration
3 . 30 . 3 min. 30 sec.
30 . 30 sec.
3. 0 . 3 min. 0 sec.
- - - - - - - - - - - - - - - - - - - - - - --- - - - -- - - - - - - - -- - - - - - - - - -

After files will have been generated, the message successfully generated will
appear. On PC files are created with the extensions bss in the folders Programs
Files/Biomedis/Biomedis M Air/Profile/Profiles Name/Complexs Name/------.bss.
4.4 Connection of device with computer, download into device, upload from
device

Software Biomedis Biomedis M Air User Guide

Connect the device Biomedis M to computer with the help of an USB-mini USB
cable! Wait until indicator of connecting device will become active (without being
struck through)!
-------------------------- ----- ---- :
Categories
Set of programs
Search
circula
Base of programs
- Set of programs of EM-therapy
-1 Circulation-1

Information about program


Device is connected
Download into device
Readout from device

Profile
Nick

Software Biomedis Biomedis M Air User Guide

Duration
7 . 0 . 7 min. 0 sec.
. Duration for frequency in sec.
Complex
Morning
Duration
7 . 0 . 7 min. 0 sec.
Program
Active protection
Center of happiness
-1 Circulation-1

Duration
3 . 30 . 3 min. 30 sec.
30 . 30 sec.
3. 0 . 3 min. 0 sec.
- - - - - - - - - - - - - - - - - - - - - - --- - - - -- - - - - - - - -- - - - - - - - - -

Choose profile the files are generated for! Click the button Download into
device! The selected profile will be downloaded into device. The question Delete

Software Biomedis Biomedis M Air User Guide

existing data from device? will appear during download. If you click Yes,
complexes of the selected profile will be downloaded into the device, and the
complexes which have been in the device will be deleted. If you select No,
downloaded complexes will be added to existing list of complexes. After indicator
of download will have disappeared, you will be allowed to disconnect the device
from PC. The message List is being created will appear on the screen in this
case. Wait until the message List is being created will disappear and main menu
of the device will appear!
Make assure that the device is connected and click the button Readout from
device to upload program complexes from the device! After finishing of readout,
the profile Data from device will appear on the list of profiles.