Beruflich Dokumente
Kultur Dokumente
Presence
Jammu & Kashmir
Jammu
Amritsar
Ludhiana
Chandigarh
Mandi
Himachal
Pradesh
Punjab
Jaipur
Jodhpur
Barmer
Kanpur
Gwalior
Ajmer
Udaipur
Gandhinagar
Ahmedabad
Mehsana
Sanand
Mundra
Jamnagar
Rajkot
Baroda
Ankleshwar
Surat
Vapi
Haryana
Hisar
Delhi
Uttara
khand
Rajasthan
Madhya Pradesh
Gujarat
Nashik Mumbai
Pune
Maharashtra
Nagpur
Belgaum
Dehradun
Moradabad
Siliguri
Guwahati
Gorakhpur
Arunachal Pradesh
Allahabad
Muzzafarpur
Gopalganj
Jorhat
Ranchi
Uttar
Pradesh
Sibsagar
Meghalaya
Bihar
Sasan
Patna
Korba
Jharkhand
Agartala
Bokaro
West
Bengal
Kolkata
Jamshedpur
Jajpur
Angul
Chattisgarh
Bilaspur
Cuttak
Orisaa
Bhubaneswar
Raipur
Bhilai
Lucknow
Indore
Bhopal
Hyderabad
Vizag
Rajahmundry
Andhra
Pradesh
Bellary
Kadapa
Karnataka
Udipi
Bangalore
Chennai
Mangalore
Coimbatore
Karaikal
Palakkad
Tamil Nadu
Kerala
Tiruneveli
Thiruvananthapuram
Manufacturing Plant
Corporate Office
Branch Office
Service Center
Global Presence
Solar Inverter / 12/ 14 / Ver.1 / Corp. Mktg / India l Spotlight - 079 3002 2324
HIGHLIGHTS
The Hitachi Solar Inverter is a Grid Tied (GT) Solar Inverter
with reactive power control and high efficiency, which is
the heart of the Solar Power Generating System. It
converts DC power generated by the Photovoltaic (Solar)
Array to AC power that is fed to the Utility Power Grid
System. The Hitachi Solar Inverter is fully compatible with
thin film and / or crystalline PV modules. With proper
maintenance and parts replacement on schedule it has an
operating life upto 25 years.
99.5%
99.0%
88F
(Bottom)
98.5%
AC 415V, 3-Phase
INVERTER
6C
PV panel
(Bottom)
42
72
52M
DC460
900V
(Bottom)
AC 300
3 3W
Control Circuit
8A
Control Power
Supply Circuit
8G
Efficiency
Grid
98.0%
97.5%
97.0%
96.5%
(Bottom)
AC 240V, 1-Phase
or
(Bottom)
DC110V
96.0%
95.5%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Output Power
KW Solar Inverter
MW Solar Inverter
02
03
www.hitachi-hirel.com
CONTROL FUNCTIONS
Monitoring (Indicators)
Inverter Status measurement data, Fault data, Historical records and
other information is displayed on the LCD screen.
Status: Inverter Status l Switchgear Status l Grid Status
Measurement
AC Output : Voltage l Current l Power l Power Factor l Frequency
DC Input :
Voltage l Current l Power
Fault Data : Inverter Failure l Grid Faults
Historical Records
Operation Record l Grid Trouble Record l Fault Record
Protections
Islanding Protection
Temperature Protection
Ground Fault Monitoring
Grid Monitoring
Optional Accessories
Ready to install containerized Inverter units.
Solar array junction boxes with string monitoring.
Integrated DC input extension cabinet
LT Panel
COMPLIANCE
Safety Testing
Enclosure Protection
Performance
EMC
Environmental Testing
IEC 62109-1
IEC 62109-2
IEC 62116
UL 1741
IEC 60529
IEC 61683
IEC 61000-6-2
IEC 61000-6-4
60068-2-1
60068-2-2
60068-2-14
60068-2-30
Mechanical
Dimensions (H x W x D) mm
(Approximate)
Weight (Kgs) (Approximate)
PV Inverter general
PV Inverter safety requirements
Islanding system
Safety
IP protection
Efficiency calculations
Emission requirements
Immunity requirements
Cold test
Dry heat test
Change of temperature
Damp heat cyclic test
Environmental Limits
Enclosure Protection
Temperature Range
Relative Humidity
Maximum Noise Level
Altitude
Cooling Air Flow
04
05
715 kW
630 kW
670 KW
715 kW
1107 A
1107 A
Three Phase
1049 A
1107 A
< 3%
300 V 10 %
350 V 10 %
370 V 10 %
50 Hz or 60 Hz 5%
Transformer-less Design
400 V 10 %
98.7%
98.4%
0.80 Lead to 0.80 Lag within max. kVA limit
500 kW
EURO Efficiency
PV Side
Maximum DC Power
MPPT Voltage Range
630 kW
670 KW
3 Level High Frequency PWM Solar Inverter
MPPT and AC Current Control
Transformer
Peak Efficiency
With the feature, the Inverter can keep operating even under
momentary voltage dip of 60% for up to 0.5 seconds.
Maximum Power Point Tracking (MPPT) Control
Inverter has a function to maximize power generation at a given
amount of solar radiation by adjusting DC voltage.
500 kW
600 kW
DC 460 to 900 V
460 V
756 kW
806 KW
DC 525 to 900 V
DC 550 to 900 V
1000 V (Heavy Failure Protection Level)
525 V
550 V
858 kW
DC 600 to 900 V
600 V
1200 A
AC 230V, 1, 300W, Max. 6.9A
< 100 W
AC 415V 3, 400W
Yes
Yes
Yes
Yes
Yes
Yes
Forced Cooling
Available operation will be continued in case of momentary voltage dip of residual positive phase.
Voltage fluctuation due to power change at inter-connecting point will be reduced to within 2%
Yes
Yes
Yes
LCD Display with Touch Screen
1 x RS 485 or TCP/IP
Yes
RS 485 or TCP-IP (Ethernet)
3 (Optional)
4
www.hitachi-hirel.com
2214 A
<3% at rated current
300 V AC
300 V 10%
350 V AC
350 V 10%
50 Hz or 60 Hz 5%
Transformer-less Design
EURO Efficiency
1250 kW
Three Phase
Transformer
Peak Efficiency
PV Side
Maximum DC Power
MPPT Voltage Range
1 MW (1000 kW)
1200 kW
1500 kW
DC 460 to 900 V
DC 525 to 900 V
1000 V (Heavy Failure Protection Level)
460 V
2400 A
525 V
2400 A
AC 230V, 1, 600W
<150W
AC 415V 3, 800W
ABOUT US
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Forced Cooling
Yes
Yes
Yes
Yes
Yes
LCD Display with Touch Screen
RS485 Modbus / Modbus TCP-IP / TC P-IP over Ethernet
Yes
RS 485 or TCP-IP (Ethernet)
3 (Optional)
4
< World Class Technology & Innovation from Hitachi, Ltd., Japan
< State-of-the-Art Manufacturing Facilities at Gandhinagar & Sanand
<
<
<
<
<
06
07
in Gujarat, India
Up to 80 MW Installations withing India and more than 1 GW
Worldwide.
In-house R&D (Research & Development) Facility, recognized by
DSIR (Department of Scientific & Industrial Research), Government
of India
An ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007
Certified Company, adhering to world class quality standards
Approved by major consultants and EPC contractors
Serving entire gamut of industries
PAN India & global presence
Offer products with greater energy efficiency & lower carbon
footprint
www.hitachi-hirel.com