Sie sind auf Seite 1von 4

PAN India

Presence
Jammu & Kashmir
Jammu
Amritsar
Ludhiana
Chandigarh

Mandi
Himachal
Pradesh
Punjab

Jaipur
Jodhpur
Barmer

Kanpur
Gwalior
Ajmer
Udaipur

Gandhinagar
Ahmedabad
Mehsana
Sanand
Mundra
Jamnagar
Rajkot
Baroda
Ankleshwar
Surat
Vapi

Haryana

Hisar
Delhi

Uttara
khand

Rajasthan

Madhya Pradesh

Gujarat

Nashik Mumbai
Pune

Maharashtra

Nagpur
Belgaum

Dehradun
Moradabad

Grid Tied Solar Inverter

Siliguri
Guwahati
Gorakhpur
Arunachal Pradesh
Allahabad
Muzzafarpur
Gopalganj
Jorhat
Ranchi
Uttar
Pradesh
Sibsagar
Meghalaya
Bihar
Sasan
Patna
Korba
Jharkhand
Agartala
Bokaro
West
Bengal
Kolkata
Jamshedpur
Jajpur
Angul
Chattisgarh
Bilaspur
Cuttak
Orisaa
Bhubaneswar
Raipur
Bhilai
Lucknow
Indore
Bhopal

HIVERTER - NP201i Series

Hyderabad
Vizag
Rajahmundry

Andhra
Pradesh

Bellary
Kadapa

Karnataka
Udipi
Bangalore

Chennai
Mangalore
Coimbatore
Karaikal

Palakkad

Tamil Nadu
Kerala
Tiruneveli
Thiruvananthapuram

Manufacturing Plant
Corporate Office
Branch Office
Service Center

Global Presence

Hitachi Hi-Rel Power Electronics Pvt. Ltd.


Gandhinagar Works
B - 14/1 & 171, GIDC Electronics Zone, Sector - 25, Gandhinagar - 382 044 Gujarat, India.
Phone: +91-79-2328 7180/81, 6170 0500, Fax: +91-79-2328 7182
Sanand Works
SM 3 & 4, Sanand - II GIDC, Industrial Estate, Bol Village, Sanand - 382 110 Gujarat, India.
Phone: +91-2717-678777, Fax: +91-2717-678700
Email: contact@hitachi-hirel.com
Web: www.hitachi-hirel.com

Solar Inverter / 12/ 14 / Ver.1 / Corp. Mktg / India l Spotlight - 079 3002 2324

Middle East l South East Asia l Africa l Australia l America

Grid Tied Solar Inverter


HIVERTER - NP201i Series

HIGHLIGHTS
The Hitachi Solar Inverter is a Grid Tied (GT) Solar Inverter
with reactive power control and high efficiency, which is
the heart of the Solar Power Generating System. It
converts DC power generated by the Photovoltaic (Solar)
Array to AC power that is fed to the Utility Power Grid
System. The Hitachi Solar Inverter is fully compatible with
thin film and / or crystalline PV modules. With proper
maintenance and parts replacement on schedule it has an
operating life upto 25 years.

HIVERTER NP 201i, Hitachi Solar Inverter Series are


among the best available GT Solar Inverters that are
suitable for Multi-Megawatt Solar Power Plants. The
transformer-less design and 3-level PWM technology
improves the efficiency of the system to 98.7%. The
Inverter has a compact design and lower weight for ease of
installation, repair and maintenance. The large touch
screen display collects real-time data and provides fault
detection diagnostics to ensure faster retrieval of
information for corrective action.

As a part of Hitachi Group Company, Hitachi Hi-Rel Power


Electronics Pvt. Ltd (HHPE) is manufacturing Grid Tied
Solar Inverters in India based on the contemporary
technology of Hitachi Ltd, Japan. It brings reliable
products supported by very high quality standards,
manufacturing processes and work culture. Assured long
term technical and spares support.

Three Level High Frequency PWM Inverter Technology


resulting in Reduction of Losses, Low Harmonic Output
Current (< 3%) & Improved Efficiency
High Efficiency up to 98.7% Including Filter Losses
IEC compliant / Third Party Approval for Entire Range of
Inverters
Reactive Power Control
Low Voltage Ride Through (LVRT) Functionality
Propriety MPPT Algorithm / Extra Wide MPPT Range
(460 V 900 V)

Optimized Cooling Fan for Higher Energy Savings as


well as Longer Fan Life
Integrated DC and AC Distribution & Protection
Independent RS 485 and TCP/IP Communication
Interfaces
Compact Product Design for Lower Footprint and Ease
of Installation
Designed Lifetime up to 25 years - With Preventive
Maintenance and Periodic Parts Replacement

HITACHI'S PRESENCE IN INDIAN SOLAR DOMAIN


State of the art Manufacturing Facility in India at Sanand
and Gandhinagar in Gujarat
Comprehensive Testing Facility with 100% Load Test
Life Cycle Service Support through Hitachi's Pan India
Service Centres

Prompt availability of Spares and Components locally in


India
Over 90 MW Hitachi Inverters feeding Power to Indian
Grid in Various States

99.5%
99.0%
88F

(Bottom)

98.5%

AC 415V, 3-Phase

INVERTER
6C

PV panel
(Bottom)

42

72

52M

DC460
900V

(Bottom)
AC 300
3 3W

Control Circuit
8A
Control Power
Supply Circuit

8G

Efficiency

Grid

98.0%
97.5%
97.0%
96.5%

(Bottom)

AC 240V, 1-Phase
or
(Bottom)
DC110V

96.0%
95.5%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Output Power

KW Solar Inverter

Highly Optimized Energy Conversion

MW Solar Inverter

Single Line Diagram of PV-Solar Inverter

02

03

Output Power Vs. Efficiency Curve

www.hitachi-hirel.com

Grid Tied Solar Inverter


HIVERTER - NP201i Series

CONTROL FUNCTIONS

TECHNICAL SPECIFICATIONS (KW SCALE)

Start / Stop Function (Emergency Switch)


a. Inverter START / STOP Switch or Contact Input Signal
(Start and stop of the Inverter is carried out by START / STOP
switches).
b. Control position can be selected by DIRECT / REMOTE Switch.
Direct Control
Direct control of the Inverter is possible by using
START / STOP Switches.
Remote Control
Remote control of the Inverter can be done by contact input
signals (START / STOP Switches) or communication.

PV Input Controlled Stand-by Function


a. When the DC input power or voltage reduces due to decrease in
solar irradiation or any other causes, the Inverter goes into stand-by
mode with its inverter switching functions turned off automatically.
In this case, the DC switchgear will be closed.

Fault Ride Through (FRT) Low Voltage Ride Through (LVRT)


Against sudden changes of amplitude or phase of AC Voltage,
Inverter high-speed detection and control capability can prevent AC
over current.

Output Power Limiting Function


When the Hitachi inverter output exceeds its maximum value, the
input power drawn will be adjusted to prevent the inverter from
being overloaded.

Solar Inverter Rating


AC-DC Conversion System
Control System
Grid Data
Power Rating
AC Grid Connection
Maximum AC Current
Output Waveform THDi
Nominal Output Voltage
Output Frequency Range

b. Upon recovery of the DC input the Inverter switching operation


will be restored automatically.

Monitoring (Indicators)
Inverter Status measurement data, Fault data, Historical records and
other information is displayed on the LCD screen.
Status: Inverter Status l Switchgear Status l Grid Status
Measurement
AC Output : Voltage l Current l Power l Power Factor l Frequency
DC Input :
Voltage l Current l Power
Fault Data : Inverter Failure l Grid Faults
Historical Records
Operation Record l Grid Trouble Record l Fault Record

Maximum DC Input Voltage (OC)


Minimum DC Input Voltage
Maximum Input Current DC
External Auxiliary Power Supply
Control Power in Operation
Control Power in Stand-by Mode
Cooling Fan Power

Auto-tuning of power factor based on Grid conditions


Fixed power factor (Can be set to Unity)
Fixed amount of reactive power
Can be based on a pre-set value or based on adjustable
settings

Protections
Islanding Protection
Temperature Protection
Ground Fault Monitoring
Grid Monitoring

Ease of Installation and Commissioning


Low weight and compact footprint saves time and resources at site

AC & DC Short Circuit and Over Current


AC & DC Over Voltage and
Temperature
Cooling (Controlled)
Fault ride Through (FRT)
Reducing Grid Voltage
Fluctuation Control
Automatic Wake-up and Shut-down

Optional Accessories
Ready to install containerized Inverter units.
Solar array junction boxes with string monitoring.
Integrated DC input extension cabinet
LT Panel

Circuit Breaker on AC Side


Switch on DC Side
Communication
Visual Display
Wired Local Monitoring
Unit-wise Integrated Data Logging
Access Interface / Field Bus
Connectivity
Analogue Input / Output
Digital Input / Relay Output

Local PC automation and system controls


I / O extensions.
SCADA for Solar PV plants
Auxiliary Power Supply solutions

COMPLIANCE
Safety Testing

Enclosure Protection
Performance
EMC

Environmental Testing

Highly Optimized Energy Conversion

IEC 62109-1
IEC 62109-2
IEC 62116
UL 1741
IEC 60529
IEC 61683
IEC 61000-6-2
IEC 61000-6-4
60068-2-1
60068-2-2
60068-2-14
60068-2-30

Mechanical
Dimensions (H x W x D) mm
(Approximate)
Weight (Kgs) (Approximate)

PV Inverter general
PV Inverter safety requirements
Islanding system
Safety
IP protection
Efficiency calculations
Emission requirements
Immunity requirements
Cold test
Dry heat test
Change of temperature
Damp heat cyclic test

Environmental Limits
Enclosure Protection
Temperature Range
Relative Humidity
Maximum Noise Level
Altitude
Cooling Air Flow

04

05

715 kW

630 kW

670 KW

715 kW

1107 A

1107 A

Three Phase
1049 A

1107 A
< 3%

300 V 10 %

350 V 10 %
370 V 10 %
50 Hz or 60 Hz 5%
Transformer-less Design

400 V 10 %

98.7%
98.4%
0.80 Lead to 0.80 Lag within max. kVA limit

Power Factor (Adjustable)

Reactive Power Control


3 Primary Types of Control Methods

500 kW

EURO Efficiency
PV Side
Maximum DC Power
MPPT Voltage Range

630 kW
670 KW
3 Level High Frequency PWM Solar Inverter
MPPT and AC Current Control

Transformer
Peak Efficiency

With the feature, the Inverter can keep operating even under
momentary voltage dip of 60% for up to 0.5 seconds.
Maximum Power Point Tracking (MPPT) Control
Inverter has a function to maximize power generation at a given
amount of solar radiation by adjusting DC voltage.

500 kW

600 kW
DC 460 to 900 V
460 V

756 kW

806 KW

DC 525 to 900 V
DC 550 to 900 V
1000 V (Heavy Failure Protection Level)
525 V

550 V

858 kW
DC 600 to 900 V
600 V

1200 A
AC 230V, 1, 300W, Max. 6.9A
< 100 W
AC 415V 3, 400W
Yes
Yes
Yes
Yes
Yes
Yes
Forced Cooling
Available operation will be continued in case of momentary voltage dip of residual positive phase.
Voltage fluctuation due to power change at inter-connecting point will be reduced to within 2%
Yes
Yes
Yes
LCD Display with Touch Screen
1 x RS 485 or TCP/IP
Yes
RS 485 or TCP-IP (Ethernet)
3 (Optional)
4

1900 x 1400 x 1000


1200
IP 20 (IP 21 Optional)
(-) 20 C to (+) 60 C
15% to 95% (Non Condensing)
75 dBA at a distance of 1 Mtr
(IEC 61672 - 1 Characteristic)
0 to 1000 Mtrs. (Option: 2000 Mtrs.)
3760 M3/Hr.

www.hitachi-hirel.com

Grid Tied Solar Inverter


HIVERTER - NP201i Series

TECHNICAL SPECIFICATIONS (MW SCALE)


Solar Inverter Rating
AC-DC Conversion System
Control System
Grid Data
Power Rating
AC Grid Connection
Maximum AC Current
Output Waveform THDi
Nominal Output Voltage
Output Voltage Range
Output Frequency Range

3 Level High Frequency PWM Inverter


MPPT and AC Current Control
1000 kW
2214 A

2214 A
<3% at rated current

300 V AC
300 V 10%

98.4% at Min DC Input Voltage


98.1% at Min DC Input Voltage
0.80 Lead to 0.80 Lag within max. kVA limit

Power Factor (Adjustable)

Maximum Input Current DC


External Auxiliary Power Supply
Control Power in Operation
Control Power in Stand-by Mode
Cooling Fan Power
Protections
Islanding Protection
DC Reverse Polarity Protection
Temperature Protection
Ground Fault Monitoring
Grid Monitoring
AC & DC Short Circuit and Over Current
AC & DC Over Voltage and Temperature
Cooling (Controlled)
Fault ride Through (FRT) (Also known
as LowVoltage Ride Through (LVRT))
Reactive Power Control
Automatic Wake-up and Shut-down
Circuit Breaker on AC Side
Switch on DC Side
Communication
Visual Display
Wired Local Monitoring
Unit-wise Integrated Data Logging
Access Interface / Field Bus
Connectivity
Analogue Input / Output
Digital Input / Relay Output
Mechanical
Dimensions (H x W x D) mm
(Approximate)
Weight (Kgs) (Approximate)
Environmental Limits
Enclosure Protection
Temperature Range
Relative Humidity
Maximum Noise Level
Altitude
Cooling Air Flow

Highly Optimized Energy Conversion

350 V AC
350 V 10%
50 Hz or 60 Hz 5%
Transformer-less Design

EURO Efficiency

Maximum DC Input Voltage (OC)


Minimum DC Input Voltage

1250 kW
Three Phase

Transformer
Peak Efficiency

PV Side
Maximum DC Power
MPPT Voltage Range

1.25 MW (1250 kW)

1 MW (1000 kW)

1200 kW

1500 kW

DC 460 to 900 V

DC 525 to 900 V
1000 V (Heavy Failure Protection Level)

460 V
2400 A

525 V
2400 A
AC 230V, 1, 600W
<150W
AC 415V 3, 800W

ABOUT US

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Forced Cooling

Incorporated in 1983 as Hi-Rel Electronics Pvt. Ltd., we are now a Hitachi


group company - Hitachi Hi-Rel Power Electronics Pvt. Ltd., recognized
as a PIONEER IN POWER ELECTRONICS. With 3 decades of experience,
we have garnered a significant level of trust in our market segment and
continue to offer world class power electronics products, value added
services & customized solutions.

Yes

Our Product Portfolio includes UPS (Uninterruptible Power Supply) for


Industrial, Commercial & Enterprise Applications, Medium Voltage & Low
Voltage Variable Frequency Drives, Steel Automation & Engineered Drives
for Customized Applications, Industrial Automation & Control Products
like PLC, SCADA & DCS, GRID TIED SOLAR INVERTER, Railway
Products and other Customized Products like UMPS, iDip (dip ride
through solutions), etc. We have rich experience in supplying Power
Back-up Products & Complete Customized Solutions for Mission Critical
Applications in Refineries, Petro-Chemicals, Power Generation, Steel &
Metal, and Process Industries as well as Critical Data Processing
Applications.

Yes
Yes
Yes
Yes
LCD Display with Touch Screen
RS485 Modbus / Modbus TCP-IP / TC P-IP over Ethernet
Yes
RS 485 or TCP-IP (Ethernet)

We believe that our core values, customer delight, quality orientation,


harmony, sincerity, pioneering spirit & growth, differentiate us from others.
With expertise, experience and an efficient product line, we will always be
your power electronics partner.
When you choose to do business with us, you are partnering with a
company who cares.

Gandhinagar, India Works


n
n
n
n

Total Area - 10,000 m2


Products Manufacturing - Industrial, Commercial &
Enterprise UPS, Grid Tied Solar Inverter & Railway products
Facilities - Designing, Engineering, Manufacturing and
Testing
In-house Product Testing Facility

3 (Optional)
4

< World Class Technology & Innovation from Hitachi, Ltd., Japan
< State-of-the-Art Manufacturing Facilities at Gandhinagar & Sanand

2078 x 2404 x 989 (additional width of 500 for Up to 16 protected inputs)


<
2000 (additional 300 kgs for up to 20 protected inputs)
<
IP 20 (IP 21 Optional)
(-) 5C to (+) 60C (no de-rating up to 50C; 1.5% de-rating per degree rise in temperature from 50C to 60C)
15% to 95% (Non Condensing)

<

75 dBA at a distance of 1 Mtr (JIS C 1509 Class 2 - A Characteristic)


0 to 1000 Mtrs. (Option: 2000 Mtrs.)

<
<
<
<

7520 M3/ Hr.

06

07

in Gujarat, India
Up to 80 MW Installations withing India and more than 1 GW
Worldwide.
In-house R&D (Research & Development) Facility, recognized by
DSIR (Department of Scientific & Industrial Research), Government
of India
An ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007
Certified Company, adhering to world class quality standards
Approved by major consultants and EPC contractors
Serving entire gamut of industries
PAN India & global presence
Offer products with greater energy efficiency & lower carbon
footprint

Sanand, India Works


n
n
n
n
n
n
n
n

Most Modern Power Electronics Manufacturing Facility in India


Modelled on Hitachi's Omika Works, Japan
Total Area - 26,000 m2
Products Manufacturing - Medium & Low Voltage Drives, Industrial
Automation & Control, Customized Products i.e. UMPS, iDip
Facilities Designing, Engineering, Manufacturing and Testing
Use of Hitachi's Omika Works based Software Tools for Engineering
and Manufacturing
Dust Free Environment and Anti-static Flooring
In-house Product Testing Facility

www.hitachi-hirel.com