Sie sind auf Seite 1von 53

1035 LINCOLN ROAD

MIAMI BEACH

HISTORICAL PRESERVATION BOARD


FIRST SUBMITTAL PACKAGE

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

PROJECT DATA

DRAWING INDEX

ZONING CLASSIFICATION:
HISTORIC DISTRICT
FEMA ZONE
GROSS LOT AREA:
MAXIMUM F.A.R.

CD-3 Commerical High Density district


FLAMINGO PARK
AE (EL. + 8.00 NGVD)
15,000 S.F.
33,750 S.F.

A0.0
A0.1
A0.2
A0.3
A0.4
A0.5
A0.6-0.7
A0.8
A0.9
A0.10-.12

II. SETBACKS & YARD REQUIREMENTS

REQUIRED

PROVIDED

FRONT (Lincoln Road):


REAR :
SIDE :
SIDE: (LENOX):

0-0
5-0
0-0
0-0

0-0
5-0
0-0
0-0

A1.0-A1.3

ARCHITECTURAL INSPIRATION IMAGES/ STREAMLINE MODERN/ CONTEXT AND HISTORY

A2.1-2.3

SOLAR STUDY DIAGRAMS

A3.01
A3.02

DEMOLITION PLAN AND ELEVATIONS


F.A.R DIAGRAMS

III. F.A.R. SUMMARY

ALLOWED

PROVIDED

GROUND FLOOR:
SECOND FLOOR:
MEZZANINE:
ROOF TERRACE:

NA
NA
NA
NA

13,376 S.F.
12,174 S.F.
4,580 S.F.
1,370 S.F.

TOTAL F.A.R.:

33,750 S.F.

31,500 S.F.

IV. BUILDING STATISTICS

ALLOWED

PROVIDED

NUMBER OF STORIES:
BUILDING HEIGHT (TO TOP OF ROOF SLAB):

5
50-0

2
50-0

A3.1
A3.2
A3.3
A3.4
A3.5
A3.6
A3.7
A3.8
A3.9
A3.10
A3.11
A3.12
A3.13
A3.14

PROPOSED SITE PLAN


EXISTING LOADING MANUEVERING DIAGRAM
PROPOSED LOADING MANUEVERING DIAGRAM
PROPOSED FIRST FLOOR PLAN
PROPOSED SECOND FLOOR PLAN
PROPOSED MEZZANINE PLAN
PROPOSED ROOF TERRACE FLOOR PLAN
RENDERED ELEVATIONS OF PROPOSED FACADE- LINCOLN ROAD
RENDERED ELEVATIONS OF PROPOSED FACADE- LENOX AVENUE
RENDERED ELEVATIONS OF PROPOSED FACADE- LINCOLN LANE
RENDERED ELEVATIONS OF PROPOSED FACADE- LINCOLN ROAD
RENDERED ELEVATIONS OF PROPOSED FACADE- LENOX AVENUE
RENDERED ELEVATIONS OF PROPOSED FACADE- LINCOLN LANE
RENDERED ELEVATIONS OF PROPOSED EAST FACADE

A4.1
A4.2
A4.3

PROPOSED MATERIALS PALETTE


PROPOSED SCREENING AND ATTACHMENT
BUILDING SECTION AND VIEW LINES

L-400
L-400R
L-500
L-501
L-502

GROUND FLOOR LANDSCAPE


ROOF TERRACE LANDSCAPE
SOUTH LANDSCAPE ELEVATION / SECTION
WEST LANDSCAPE ELEVATION
NORTH LANDSCAPE ELEVATION

LSK - 1.0
LSK - 2.0
LSK - 3.0
LSK - 4.0
LSK - 5.0
LSK - 6.0
LSK - 7.0

PROPOSED ROOF LIGHTING PLAN RENDER


PROPOSED ROOF LIGHTING PLAN
PROPOSED STREET LEVEL LIGHTING RENDER PLAN - OPTION 1 - CONTINUOUS LINEAR STRIP
PROPOSED STREET LEVEL LIGHTING RENDER PLAN - OPTION 1 - CONTINUOUS LINEAR STRIP
SECTION DIAGRAMS
SECTION DETAIL DIAGRAM
PRELIMINARY CUTSHEETS

A5.1
A5.2

RENDERING - LINCOLN ROAD WEST VIEW


RENDERING - LINCOLN ROAD VIEW

I. SITE DATA SUMMARY

PROJECT TEAM
ARCHITECT: TOUZET STUDIO
LANDSCAPE ARCHITECT: GREEN SPACE STRATEGIES
LIGHTING DESIGN: LIGHTING WORSHOP

1035 LINCOLN ROAD: MIAMI BEACH

COVER
DATA + INDEX
SITE LOCATION
SITE VIEWS
EXISTING BUILDING PHOTOGRAPHS - LINCOLN ROAD
EXISTING BUILDING PHOTOGRAPHS - LINCOLN LANE
HISTORIC STUDY
LINCOLN ROAD HISTORY
EXISTING SITE PLAN
EXISTING ELEVATIONS

SURVEY

A0.1
PROJECT DATA

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

LENOX AVENUE

LINCOLN ROAD
LENOX AVENUE

LINCOLN ROAD

LOCATION MAP

LOCATION MAP

1035 LINCOLN ROAD: MIAMI BEACH

A0.2
SITE LOCATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

LINCOLN ROAD

LENOX AVENUE

LOCATION MAP

1035 LINCOLN ROAD: MIAMI BEACH

A0.3
SITE VIEWS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

B
A

LENOX AVENUE

LINCOLN ROAD

1035 LINCOLN ROAD: MIAMI BEACH

KEY PLAN

A0.4
EXISTING BUILDING PHOTOGRAPHS LINCOLN ROAD

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

LENOX AVENUE

LINCOLN ROAD

1035 LINCOLN ROAD: MIAMI BEACH

KEY PLAN

A0.5
EXISTING BUILDING PHOTOGRAPHS LINCOLN LANE

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

D
OA

LE

NO
X

R
LN

LE

CO

AV
E

LIN

D
OA

NO
X

NU

R
LN

CO

AV
E

LIN

NU

1925 SENDER BUILDING


UNKNOWN ARCHITECT

SITE CONTEXT 1925

SITE CONTEXT 1938

SENDER BUILDING CONTEXT CIRCA 1934

1938 MCALLISTER BUILDING


ARCHITECT : ROBERT M. LITTLE

1035 LINCOLN ROAD: MIAMI BEACH

A0.6
HISTORIC STUDY

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

D
OA n)
R
LN tria
CO edes
N
I
L
(p

LE

NO
X

AV
E

D
OA n)
R
LN tria
CO edes
N
I
L
(p

LE

NO
X

NU

EXISTING BUILDING DEMOLISHED

AV
E

NU

SITE CONTEXT 1999

SITE CONTEXT 2014

1999 NEW POTTERY BARN BUILDING


ARCHITECT : HAWRYLEWICZROBERTSON ARCHITECTS

1035 LINCOLN ROAD: MIAMI BEACH

A0.7
HISTORIC STUDY

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

LINCOLN ROAD: THEN AND NOW

Lincoln Road is the civic-commercial urban centerpiece of Miami Beach. Initially developed by Carl Fisher as
the commercial main street of his Alton Beach development, he named it after his hero Abraham Lincoln.

MIami Beach is a layering of consecutive urban visions, built one on top of the other and compacted in time and space.
Each vision left an architectural & urban imprimatur on its structure, influencing the development of an eclectic local
vocabulary of buildings and spaces.

Inspired by the work of the Brazilian modernist landscape architect Roberto Burle-Marx, Lapidus took cues form the vibrant paving patterns of
the broad promenades along Ipanema and Copacabana beaches. He envisioned black-andwhite-striped pavement stretching the entire width
of the right-of-way from building face to building face......

1035 LINCOLN ROAD: MIAMI BEACH

A0.8

LINCOLN ROAD HISTORY

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

POTTERY BARN

WILLIAM-SONOMA

BEBE

APPLE

INTERMIX

1035 LINCOLN ROAD: MIAMI BEACH

ATHLETA

GAP

A0.9
EXISTING SITE PLAN

SCALE: 1/32 - 1-0

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A0.10


EXISTING LINCOLN ROAD ELEVATION AND PHOTOS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A0.11


EXISTING LENOX AVENUE ELEVATION AND PHOTOS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A0.12


EXISTING LINCOLN LANE ELEVATION AND PHOTOS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

STREAMLINE MODERNE
A style related to Art Deco is Streamline
Moderne (or Streamline) which emerged
during the mid-1930s. Streamline was
influenced by modern aerodynamic principles
developed for aviation and ballistics to
reduce air friction at high velocities. Designers
applied these principles to cars, trains, ships,
and even objects not intended to move, such as
refrigerators, gas pumps, and buildings.(wikipedia)

1035 LINCOLN ROAD: MIAMI BEACH

A1.1
1930S-40-S STREAMLINE MODERNE

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

Lapidus and the Lincoln Pedestrian Mall


Lincoln Road, a Cold War-era civic project in Miami Beach, has stood the test of time, thanks to the stunning work of local architect Morris Lapidus. As the malls 50th anniversary approaches in 2010, Lincoln Road is reemerging as one of Miamis biggest
draws.
Alastair Gordon, Wall Street Journal March 2009

Its a six-block procession of eye candy but the Lapidus follies arent just ornamental. They carve and animate the space as one walks down
the mall, expanding it in places while contracting it in others. (There is also something oddly infantilizing about the bone-white structures, as
if they were oversized Froebel blocks.) (Photo: Alastair Gordo

1035 LINCOLN ROAD: MIAMI BEACH

A1.2
CONTEXT-HISTORY

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

A1.3
CONTEXT

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

9:00 AM

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

12:00 PM

5:00 PM

A2.1
SOLAR STUDY: AUTUMN / SPRING EQUINOX (DAYLIGHT SAVINGS)

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

7:00 AM TO 12:00 PM

12:00 PM TO 7:00 PM

1035 LINCOLN ROAD: MIAMI BEACH

A2.2
SOLAR STUDY: AUTUMN/ SPRING EQUINOX

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

9:00 AM

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

12:00 PM

5:00 PM

A2.3
SOLAR STUDY: AUTUMN / SPRING EQUINOX (DAYLIGHT SAVINGS)

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

NORTH ELEVATION - LINCOLN ROAD

EAST ELEVATION - LENOX AVENUE

FLOOR PLAN

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.01


DEMO PLAN AND ELEVATIONS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

GROUND LEVEL : 13,376 SF

SECOND LEVEL: 12,174 SF

MEZZANINE : 4,580 SF

ROOF TERRACE :1,370 SF


TOTAL : 31,500 SF

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.02

F.A.R DIAGRAMS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

A3.1
PROPOSED SITE PLAN

SCALE: 1/32 - 1-0

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

LOADING TRUCK MANEUVERING


VEHICULAR MANEUVERING

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.2


EXISTING LOADING MANEUVERING DIAGRAM

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

DELIVERY/TRASH PICK UP:


1.GARBAGE PICK UP: 3-5 TIMES A WEEK
2.FEDEX DELIVERY: 1-2 TIMES A DAY

LOADING TRUCK MANEUVERING


VEHICULAR MANEUVERING

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.3


PROPOSED LOADING MANEUVERING DIAGRAM

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.4


PROPOSED FIRST FLOOR PLAN

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.5


PROPOSED SECOND FLOOR PLAN

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.6


PROPOSED MEZZANINE FLOOR PLAN

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.7


PROPOSED ROOF TERRACE PLAN

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.8


PROPOSED LINCOLN ROAD ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.9


PROPOSED LENOX AVENUE ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.10


PROPOSED LINCOLN LANE ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/32 - 1-0 A3.11


PROPOSED LINCOLN ROAD ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.12


PROPOSED LENOX AVENUE ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.13


PROPOSED LINCOLN LANE ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
GL-2
TRANSLUSCENT, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A3.14


PROPOSED EAST ELEVATION

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

PT-1

CF-1

CF-2

GL-1 | MT-1

CP-1

CP-1

CP-1

CF-2

MATERIAL LEGEND:
GL-1
CLEAR, LAMINATED GLASS UNITS WITH LARGE MISSILE IMPACT INTERLAYER.

DARK GREY FINISH ON METAL STORE FRONT SYSTEM.
CF-1
ARCHITECTURAL CONCRETE WALL FINISH, SEALED
CF-2
POLISHED, EXPOSED AGGREGATE TERRAZZO/CONCRETE
CP-1
PRE-CAST CONCRETE PANEL RAINSCREEN ON STRUCTURAL STEEL FRAMING SYSTEM
MTL-1
OPERABLE AND FIXED METAL SCREEN PANELS
PT-1
PAINTED STUCCO TO MATCH CONCRETE.

1035 LINCOLN ROAD: MIAMI BEACH

A4.1
PROPOSED MATERIAL PALETTE

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

erutcurtS-buS

SUB- Structure
system top-hung off the roof slab structure, propped back for wind

b depporp ,erutcurts bals foPL or eht ffo gnuh-pot metsys

Detail Ductal Panel


Detail Ductal Panel

Ductal
view Detail
fromfrom
inside
View
inside Panel
view from inside

approx. 1

approx. 1
Parapet above

clips)

Wind needles

Wind needles
2nd floor slab

seldeen dniw
bals roolf dn2

Wind needles

seldeen dniw
tnorferots evoba

storefront

approx. 1

Detail Ductal Panel

seldeen dniw
bals eninazzem

Mezzanine slab

level foor
)revelitnac niam(

ROOF TERRACE
39' - 0"

approx. 1

(Main cantilever)

liated

alu receiver
channels
alu receiver
(for
channels
(for
undercut
undercut
clips)

(T- profiles)

Wind needles

ah lla
eddih
istuo
atcud

hangers
(T- profiles)
hangers

evoba teparap
level foor

roof level

wind needles
wind needles

view from outside

Detail Ductal
Panel
Detail
Ductal Panel
NikeView
- Ductalfrom
Faadeoutside
Sub-structure - Progress

SECOND FLOOR
17' - 0"

slide - 6 -

Nike - Ductal Faade Sub-structure


- Progress
Detail
Ductal
view
from
outsidePanel

slide - 6 -

view from outside

dnuorg
Ground

ssergorP - erutcurts-buS edaaF latcuD - ekiN


FIRST FLOOR
0' - 0"

wind needles

wind needles
wind

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

needles

A4.2
slide
slide
- 5 -- 5 PROPOSED SCREENING, ATTACHMENT AND CALCULATIONS

Nike -Nike
Ductal
Faade
Sub-structure
- Progress
- Ductal
Faade
Sub-structure
- Progress

Nike - Ductal Faade Sub-structure - Progress

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

slide - 5 -

1035 LINCOLN ROAD: MIAMI BEACH

SCALE: 1/16 - 1-0 A4.3


BUILDING SECTION AND VIEW LINES

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH


No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

POWER PIPE MOUNTED ACCENT


UPLIGHT AT TREES - TYP.

PRELIMINARY ROOF LIGHTING PLAN RENDER


103512.04.2014
LINCOLN ROAD: MIAMI BEACH
No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

NIKE MIAMI, LINCOLN ROAD


CONCEPTUAL LIGHTING DESIGN

SCALE: 1/16LSK-1
- 1-0 LSK1.0
PROPOSED ROOF LIGHTING PLAN RENDER

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2
X2

X2
X2
X2
X2

X2
X2

X2
X2

X2

X2

X2
X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

X2

PRELIMINARY ROOF LIGHTING PLAN


12.04.2014
1035 LINCOLN ROAD: MIAMI BEACH

NIKE MIAMI, LINCOLN ROAD


CONCEPTUAL LIGHTING DESIGN

LSK-2

SCALE: 1/16 - 1-0 LSK2.0

PROPOSED ROOF LIGHTING PLAN

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

LINEAR IN-GRADE UPLIGHT


ALONG CONCRETE PORTION
OF FACADE

CONTINUOUS DOWNLIGHT AT
SCREEN- TYP.

LINEAR UPLIGHT AT EXTERIOR


CONCRETE WALL

PRELIMINARY STREET LEVEL LIGHTING RENDER PLAN- OPTION 1 CONTINUOUS LINEAR STRIP

103512.04.2014
LINCOLN ROAD: MIAMI BEACH
No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

NIKE MIAMI, LINCOLN ROAD


CONCEPTUAL LIGHTING DESIGN

SCALE: 1/16 LSK-3


- 1-0 LSK3.0
PROPOSED STREET LEVEL LIGHTING RENDER PLAN - OPTION 1 - CONTINUOUS LINEAR STRIP

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

CONTINUOUS X1

CONTINUOUS X1

CONTINUOUS X1
CONTINUOUS X1

CONTINUOUS X3

PRELIMINARY STREET LEVEL LIGHTING PLAN - OPTION 1 CONTINUOUS LINEAR STRIP

12.04.2014
1035 LINCOLN ROAD: MIAMI BEACH
No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

NIKE MIAMI, LINCOLN ROAD


CONCEPTUAL LIGHTING DESIGN

LSK-4

SCALE: 1/16 - 1-0 LSK4.0


PROPOSED STREET LEVEL LIGHTING RENDER PLAN - OPTION 1 - CONTINUOUS LINEAR STRIP

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

PL

PL

ROOF TERRACE
(43.35 NGVD39' - 0"

ROOF TERRACE
39' - 0"
ROOF TERRACE
39' - 0"

CONTINUOUS LED AT SCREEN ELEMENT

ROOF TERRACE
(43.35 NGVD39' - 0"

CONTINUOUS X1

B-K LIGHTING

POWER PIPE MOUNTED LED AT PLANTERS

ROOF TERRACE
39' - 0"

FLOODLIGHTS

ROOF TERRACE
39' - 0"

NITE STAR II
MATERIAL*

NSII
Adjust-e-Lume
(BKSSL)

MR16 Halogen

I love this fixture because... of its versatility. We use it often as an outdoor arch
fixture to accent pathways in areas where a recessed product will not work

extreme for it to be effective. The 1" setback combined with a hex louvre kee

away from the eyes and when coupled with the 360SL knuckle aiming is
of cake.

Jarron Pew, HELIUS Lighting Group, BKU Spr


FOR USE WITH

Power Supplies

Options

SECOND FLOOR
17' - 0"

SCREEN ELEMENT
Mounting

SECOND FLOOR
(21.35 NGVD17' - 0"
SECOND FLOOR
17' - 0"
SECOND FLOOR
17' - 0"
SECOND FLOOR
(21.35 NGVD17' - 0"

SECOND FLOOR
17' - 0"

9 7/8"
(251mm)

21
(57

CONTINUOUS X1

4 3/8"
(111mm)

CONTINUOUS X3

Shown with optional 360SL knuckle


in Bronze Satin (BZP) finish

FIRST FLOOR
0' - 0"

1 5/8"
(41mm)

28

PLANTERS

1 5/8"
(41mm)

*Nite Star II with MR16 Halogen source is only available in aluminum and brass. See page 30

www.bklighting.com

FIRST FLOOR
0' - 0"
FIRST FLOOR
(4.35 NGVD0' - 0"

BK_General_Catalog_2014_FINAL.indd 28

FIRST FLOOR
(4.35 NGVD 0' - 0"
FIRST FLOOR
0' - 0"

CONTINUOUS IN-GRADE LINEAR UPLIGHT

FIRST FLOOR
0' - 0"

SECTION DIAGRAM AT SCREEN ELEMENT

12.04.2014

NIKE MIAMI, LINCOLN ROAD


CONCEPTUAL LIGHTING DESIGN

SECTION DIAGRAM AT BUILDING B

1035 LINCOLN ROAD: MIAMI BEACH


NIKE MIAMI, LINCOLN ROAD
CONCEPTUAL LIGHTING DESIGN
No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

LSK-5

LSK5.0
SECTION DIAGRAMS

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

ROOF TERRACE
ROOF TERRACE
39' - 0"
(43.35 NGVD39' - 0"

POWER PIPE-MOUNTED LED


FIXTURE
42 HIGH PLANTER
SECOND FLOOR
SECOND
(21.35
NGVDFLOOR
17' - 0"
17' - 0"

FIRST FLOOR
FIRST FLOOR
0' - 0"
(4.35 NGVD 0' - 0"

1035 LINCOLN ROAD: MIAMI BEACH

LSK6.0
SECTION DETAIL DIAGRAMS

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

Housing:

Mounting Optio

LOG ASHRAE - Lumenfacade,5W/ft ASHRAEcompliant

UMP - FixedMou

LOG RO - LumenfacadeRegularOutput,8.5W/ft

UMAS - Universa

LOG HO - LumenfacadeHighOutput,15.25W/ft

WAM2 - Adjusta

WAM6 - Adjusta

WAM12 - Adjust

Voltage:

FLOODLIGHTS

120 - 120volts
208 - 208volts
240 - 240volts
277 - 277volts
NSII-LED

SPECIFIER

TYPE

ZONE

SKU

NOTE

PROJECT:

Approved for installation

4 7/16
(112mm)

within clothing storage space as

2 1/4" Dia.
(57mm)

High Output

MIN. INCREMENT = 1 / For Maximum increments see individual driver pages

8024 83+CRI 6.0W /ft. 546 Lm/ft.

0.75

0.64

1.56

1.0
0.22

0.18

Mid Output

F
F

MIN INCREMENT = 2 / For Maximum increments see individual driver pages

4024 83+CRI 3.0W /ft. 279 Lm/ft.

4924 94+CRI 2.8W /ft. 236 Lm/ft.

F
0.55

0.48
4024/4924 SERIES

UL E364348

1.12

3W/FT 24VDC

2.0
0.25

0.18

COLOR
CODE

22
26
27
29
34
39

83+ CRI WHITE

SINGLE BIN

F
F
F
F
F

4000 SERIES

CCT

2150K 94CRI
2650K 97CRI
2700K 94CRI
2950K 92CRI
3450K 94CRI
3950K 94CRI

COLOR
CODE

CCT

2700K
3000K
3500K
4000K
6000K

27
30
35
40
60

COLORS
F RED
F GREEN
F BLUE
F AMBER
F PINK

3000 SERIES
Standard Output

The extrusion made from high quality aluminum is designed for flexible or rigid LED strips that are 8 - 10 mm wide. One of the
accessories offered for the extrusion is a cover that shades and protects LEDs inside the profile. Cover is made of polycarbonate.
HR-ALU extrusion is designated for the outdoor applications as a waterproof fixture. Its components (LEDs, cover, end caps and
extrusion) must be properly sealed with neutral silicone (recommended Dow Corning 799 EU) to achieve waterproof level IP 67
(class of resistance against ingress of solid objects, dust and water).
The extrusion is designed to be mounted to surfaces, such as ceramic tiles with the use of mounting adhesive. The design and
parameters of HR-ALU extrusion and its cover make the fixture durable and sturdy when mounted in the floor, as well as resistant
to standard loads, cleaning and general floor maintenance.

Applications

F
F

MIN. Increment = 4 / For Maximum increments see individual driver pages

Due to its high integrity and compact size, HR-ALU extrusion is ideal for use in bathroom, shower, floor applications or areas
exposed to water. The extrusion is as high as the average thickness of the ceramic tile and mounting adhesive, thus it is very often
mounted in floors as it integrates with the floor surface. Additionally, it can be used to illuminate exterior architectural elements,
such as building facades, terraces, gardens, etc.

Both Sold Separately

3924 94+CRI 1.4W /ft. 116 Lm/ft.

0.55

0.48
3024/3924 SERIES

UL E364348

1.12

1.5W/FT 24VDC

4.0
0.25

0.18

LED

Type:

- NSII - LED - e36 -

SP

A5

- BZW -

12

11

- 360SL

FEATURES AND BENEFITS

NSII - Nite Star II


LED - e Technology with Integral Dimming Driver (25W min. load when dimmed)*

3"Dia.
(76mm)

*Requires magnetic Low Voltage dimmer

LED Type
e36 - 8WLED/2.7K
e22 - 8WLED/3K

9 7/8"
(251mm)

e23 - 8WLED/4K
e27 - 8WLED/Amber

2 1/4" Dia
(57mm)
4 3/8"
(111mm)

Optics*
NSP - Narrow Spot (Red Indicator)
SP - Spot (Green Indicator)

MFL - Medium Flood (Yellow Indicator)


WFL - Wide Flood (Blue Indicator)

Shown with optional 360SL knuckle


in Bronze Satin (BZP) finish

1 5/8"
(41mm)

**Please see Adjust-e-Lume photometry to determine desired intensity.


28

Finish
Powder Coat Color

Satin

Wrinkle

Bronze

BZP

BZW

Black

BLP

BLW

White (Gloss)

WHP

WHW

Aluminum

SAP

Verde

VER

Machined

MAC

Polished

POL

MitiqueTM

MIT

Stainless Finish
Machined

MAC

Polished

POL
BRU

Brushed

Interior use only.

ABP

BK_General_Catalog_2014_FINAL.indd 28

CMG

Cascade Mountain Granite

RMG

Rocky Mountain Granite

AMG Aleutian Mountain Granite

CRI

Cracked Ice

SDS

Sonoran Desert Sandstone

AQW Antique White

CRM

Cream

SMG

Sierra Mountain Granite

BCM

Black Chrome

HUG

Hunter Green

TXF

Textured Forest

BGE

Beige

MDS

Mojave Desert Sandstone

WCP

Weathered Copper

BPP

Brown Patina Powder

NBP

Natural Brass Powder

WIR

Weathered Iron

CAP

Clear Anodized Powder

OCP

Old Copper

Antique Brass Powder

27K - 2700K
30K -3000K
35K -3500K
Performance:
40K - 4000K
Minimum1fc(10.7lux)@129feet(39.3m)distance
(4000K,4unit,10x60optic,HOversion)
RD - Red
2,929deliveredlumensand16,765candelasatnadir
(4000K,4unit,10x60optic,HOversion)
GR - Green
CRIvalues:85+(2700K),80+(3000K),78+(4000K)
Lumenmaintenance120,000hrs [L70@25C]
BL - Blue
LumenmeasurementscomplywithLM-79-08standard

Also available in RAL Finishes


See submittal SUB-1439-00

13 - Rectilinear Lens

Option:

PIN ID / WIRE COLOR / USE


N
1
2
3

Optics:

10x10 - 10x10

3
3
3
3
13 " ,25 " ,37 " ,49 "
8
8
8
8
[340mm,645mm,949mm,1254mm]

Input Volts
12VAC/DC 50/60Hz

InRush Current
<1A (non-dimmed)

LM79 DATA
BK No.
e36
e22
e23
e27

Dimmable
Magnetic Low Voltage Dimmer

L70 DATA
CCT (Typ.)
2700K
3100K
4100K
Amber (590nm)

Input Watts
(Typ.)

8.4
8.4
8.4
7.9

CRI (Typ.)
90
90
75
~

B-K LIGHTING

5"

Minimum Rated Life (hrs.)


70% of initial lumens (L70)

50,000
50,000
50,000
50,000

1
3 "
2
[89mm]

30x60 - 30x60

Operation Ambient Temperature


-10F-130F

*OPTICAL DATA
Beam Type
Narrow Spot
Spot
Medium Flood
Wide Flood

40429 Brickyard Drive Madera, CA 93636 USA


559.438.5800 FAX 559.438.5900
www.bklighting.com info@bklighting.com

Angle
14
18
25
36

SUBMITTAL DATE

08-11-14

4"*
[102mm]
*2"[51mm]on1ftconfiguration

Visual Indicator
Red Dot
Green Dot
Yellow Dot
Blue Dot

GREEN
WHITE
BLACK
RED
ORANGE

GROUND
NEUTRAL
LIVE 120-277V
0-10V / DATA +
0-10V / DATA -

10

10

10

60

30

60

ETE - End-to-en
needed
CRC -Corrosion-r

60x60 - 60x60

60

60

5 year warranty

DRAWING NUMBER

1/8

SUB-2192-00

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

2012.10.25
EM - R50

X1- COVE MOUNTED, CONTINUOUS WATER RESISTANT LINEAR LED STRIP WITH IP67 EXTRUSION ALONG EXTERIOR

GROUND
NEUTRAL
LIVE 120-277V

Wiring detail - dimming

16
10x60 - 10x60
[59mm]

DRIVER DATA

AIONLED.COM | (415) 255-AION

GREEN
WHITE
BLACK

360SL - 360SL Rotational Knuckle Mounting System

IP 67 (sealed version), IP 20 (unsealed extrusion)


1 m / 2 m (can be cut to any size)
body aluminum, cover polycarbonate (PC), end cap polypropylene (PP)

Product is RoHS compliant.

N
1

Linevoltageluminairefor120to277V
Poweranddatain1cable(#16-5)
Upto88feetwithasingle120Vpowerfeed,HOversion
5W/ftversionmeetsASHRAEstandardsforlinearlighting
onbuildingfacades
8.5W/ftRegularOutputversion
15.25/ftHighOutputversion
0-10volt,DMXorDALIdimmingoptions

Option

Technical specification
Ingress Protection Rating
Available lengths
Material

PIN ID / WIRE COLOR / USE

Electrical :

Wiring detail - non dimming

1 5/8"
(41mm)

Resolutionperfootorperfixture(seepage5)
Operatingtemperatures:-25Cto50C[-13Fto122F]

11 - Honeycomb Baffle

end cap
without hole (00010)
with hole (00347)

3"Dia.
(76mm)
6 1/2"
(165mm)

10/15/2014 7:54:43 AM

Shielding

cover
frosted (0945)

DIM - 0-10VDim
(10%minimu
DMX 1FT - DMX
(1%minimum
DMX 1FX - DMX
(1%minimum
DALI - DALIDimm
(1%minimum
NO - NoDimmin

Colors and Color temperatures:

Lowcoppercontentextrudedaluminumhousing
Availablein1,2,3or4sections
Electro-staticallyappliedpolyesterpowdercoatfinish
Machinedaluminumendcapsandsiliconegaskets
Stainlesssteelhardware
Cleartemperedglass
3"Dia.
10x10,10x60,30x60or60x60optics
(76mm)
IP66
7 3/8"
Corrosion-resistantoptionformarineenvironments
(187mm)

*Nite Star II with MR16 Halogen source is only available in aluminum and brass. See page 307 for Catalog ordering information.
www.bklighting.com

Premium Finish

Brass Finish

1 5/8"
(41mm)

1 5/8"
(41mm)

A9 (Standard), A8, A7, A6, A5, A4, A3, A2, A1

Aluminum Finish

Dimming:

Physical :

Series

Source

Mounting

Blank - Aluminum
B - Brass
S - Stainless Steel

12 - Soft Focus Lens

Component of a complete system including: Aion LED A-Track Light Engine, Aion LED A-Track housing with diffuser lens, & Aion LED driver (power supply). Dimmer not included.
Approved dimmers, controls, power supplies, cable, & other components only. Contact Aion LED for questions regarding compatibility. Electrician installed. Strictly adhere to NEC & local
building code. Limited 5-year warranty against manufacturing defects only, does not cover labor; voided by: inadequate ventilation, field modifications, installation by unqualified personnel,
unapproved controls, drivers, cabling, other devices, not following installation guidelines & protocol, general negligence. Installer assumes all liability with regard to property & safety. This
product is UL listed. See separate: Aion LED Warranty Terms & additional instructional materials for more information. Authorized installers only. Systems tested prior to shipping.

Copyright 2014 Aion LED. All Rights Reserved

Order #

Options

Lens Type

-or- clear silicone adhesive (outdoor, porous surfaces)

3024 83+CRI 1.5W /ft. 137 Lm/ft.

CATALOG NUMBER LOGIC

Products related to the Extrusion

#WR-MT mounting tape (indoor, sealed surfaces)

Project name:

NOTES:

Adjust-e-Lume Output Intensity** (Choose factory setting)

R
G
B
A
PK

Compatible with:

MAX Fixture Length= 32' / Class 2 Circuit Limitation=56'

Jarron Pew, HELIUS Lighting Group, BKU Spring 2006

WHITE & STATIC COLORS

12 -133/8inches(340mm)(2kg/4.5lbs)
24 - 253/8inches(645mm)(3.17kg/7lbs)
36 - 373/8inches(949mm)(4.75kg/10.5lbs)
Qty:
48 - 493/8inches(1254mm)(6.35kg/14lbs)

Client:

of cake.

Material

CRI = Color Rendering Index


CCT = Correlated Color Temperature

away from the eyes and when coupled with the 360SL knuckle aiming is a piece

SOURCE:

Example

HR-ALU LED extrusion article number B1889

SINGLE BIN

2 1/4" Dia.
(56mm)

NSII

Product characteristics

92+ CRI WHITE

F
F
F
F
F
F

8924 94+CRI 5.6W /ft. 463 Lm/ft.


8024/8924 SERIES

F
F

1 5/8
(41mm)

DATA SHEET

COLOR

8000 SERIES

3 7/8
(99mm)

Patent Pending
Adjust-e-Lume

lumenfacade

SPECIFICATION SHEETLength:

extreme for it to be effective. The 1" setback combined with a hex louvre keeps glare

Power Supplies

set forth by NEC Article 410.16


1 5/8
(41mm)

MR16 Halogen

FOR USE WITH

4 7/16
(112mm)

3 7/8
(99mm)

Adjust-e-Lume
(BKSSL)

fixture to accent pathways in areas where a recessed product will not work or is too

CATALOG
NUMBER:

IP67 WET LOCATION

SI -SilverSandTe
BK - BlackSandT
WH -White
CC - Custom(ple

NSII

I love this fixture because... of its versatility. We use it often as an outdoor architectural

TYPE:

24V DC, DIMMING, CLASS 2

SERIES

MATERIAL*

TECHNOLOGY

TECHNOLOGY

LINEAR FIXTURE

NITE STAR II

B-K LIGHTING

with

PROJECT

NITE STAR II

1/1

Finish:

Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6

8/8

2012.10.25

X2- POWER-PIPE MOUNTED LED AT TERRACE PLANTERS

1.877.937.3003 P. 514.937.3003 F. 514.937.6289

info@lumenpulse.com www.lumenpulse.com
Copyright 2012 Lumenpulse

Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6

Lumenpulse reserves the right to make changes to this product at any time without prior notice
and such modification shall be effective immediately.

1.877.937.3003 P. 514.937.3003 F. 514.937.6289

info@lumenpulse.com www.lumenpulse.com
Copyright 2012 Lumenpulse

Lumenpulse reserves the right to make changes to this product at any time without prior notice

modification
shallLED
be effective
X3- ARMATURE
CONTINUOUS 30 xand
60such
HIGH
OUTPUT
AT immediately.
EM - MOUNTED,
R50
SCREEN ELEMENT

2501 27th Ave, Suite F-10, Vero Beach, FL 32960 / United States / Customer Service: sophia@klusdesign.com / (Ph.) 772 321 2260, 772 569 6655

PRELIMINARY CUTSHEETS
1035 LINCOLN ROAD: MIAMI BEACH
12.04.2014

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

NIKE MIAMI, LINCOLN ROAD


CONCEPTUAL LIGHTING DESIGN

LSK7.0
PRELIMINARYLSK-10
CUTSHEETS

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

A5.1
LINCOLN ROAD WEST VIEW

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

1035 LINCOLN ROAD: MIAMI BEACH

A5.2
LINCOLN ROAD VIEW

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

Digitally signed by Andrew


Snyder
DN: cn=Andrew Snyder,
o=Landtec Surveying, Inc., ou,
email=asnyder@landtecsurvey.co
m, c=US
Date: 2014.06.25 13:05:26 -04'00'

1035 LINCOLN ROAD: MIAMI BEACH

SURVEY

No copies, transmissions, reproductions or electronic manipulation of any portion of these drawings in whole or in part are to be made
without the express written permission of Touzet Studio Design & Architecture. All designs indicated in these drawings are property of
Touzet Studio Design & Architecture. All copyrights reserved (c) 2014.

HISTORICAL PRESERVATION BOARD SUBMITTAL: JANUARY 09, 2015

Das könnte Ihnen auch gefallen