Mitsubishi Mini-Split Single Zone Systems

Wall Mounted
Systems

Indoor Unit

Outdoor Unit

Cooling Capacity

Heating Capacity

ODB 95, EAT 80/67

ODB 17, EAT 70

Total

Sensible

Total

Voltage

MCA
(Outdoor
Unit)

MOCP
(Outdoor
Unit)

Refrigerant Pipe
SEER
Max Height

Max Length

Gas Side OD Liquid Side OD


(in)
(in)

M-Series Wall Mounted Cooling Only


MSY-GE09NA

MUY-GE09NA

9,000

7,380

NA

208-230/1

12

15

21

40'

65'

3/8

1/4

MSY-GE12NA

MUY-GE12NA

12,000

8,880

NA

208-230/1

12

15

20.5

40'

65'

3/8

1/4

MSY-GE15NA

MUY-GE15NA

14,000

11,200

NA

208-230/1

12

15

21

40'

65'

1/2

1/4

MSY-GE18NA

MUY-GE18NA

17,200

12,212

NA

208-230/1

14

15

19.2

50'

100'

1/2

1/4

MSY-GE24NA

MUY-GE24NA

22,500

16,875

NA

208-230/1

17

20

19

50'

100'

5/8

3/8

MSY-D30NA

MUY-D30NA

30,700

19,648

NA

208-230/1

21

25

16

50'

100'

5/8

3/8

MSY-D36NA

MUY-D36NA

34,600

21,452

NA

15.1

50'

100'

5/8

3/8

MSZ-GE09NA

MUZ-GE09NA

9,000

7,380

6,600

208-230/1

12

15

21

40'

65'

3/8

1/4

MSZ-GE12NA

MUZ-GE12NA

12,000

8,880

8,800

208-230/1

12

15

20.5

40'

65'

3/8

1/4

MSZ-GE15NA

MUZ-GE15NA

14,000

11,200

11,300

208-230/1

12

15

21

40'

65'

1/2

1/4

MSZ-GE18NA

MUZ-GE18NA

17,200

12,212

13,400

208-230/1

14

15

19.2

50'

100'

1/2

1/4

MSZ-GE24NA

MUZ-GE24NA

22,500

16,875

16,000

208-230/1

17

20

17.5

50'

100'

5/8

3/8

MSZ-D30NA

MUZ-D30NA

30,700

19,648

19,500

208-230/1

21

25

14.5

50'

100'

5/8

3/8

MSZ-D36NA

MUZ-D36NA

33,200

20,584

21,800

208-230/1
21
25
P-Series Wall Mounted Cooling-Only

14.5

50'

100'

5/8

3/8

PKA-A12HA

PUY-A12NHA

12,000

9,720

NA

208-230/1

13

15

15.2

100'

100'

1/2

1/4

PKA-A18HA

PUY-A18NHA

18,000

12,240

NA

208-230/1

13

20

15.3

100'

100'

1/2

1/4

PKA-A24KA

PUY-A24NHA

24,000

18,480

NA

208-230/1

18

30

17

100'

165'

5/8

3/8

PKA-A30KA

PUY-A30NHA

30,000

21,000

NA

208-230/1

25

40

15.5

100'

165'

5/8

3/8

PKA-A36KA

PUY-A36NHA

34,200

23,940

NA

14

100'

165'

5/8

3/8

PKA-A18HA

PUZ-A18NHA

18,000

12,240

13,000

208-230/1

13

20

15.3

100'

100'

1/2

1/4

PKA-A24KA

PUZ-A24NHA

24,000

18,480

18,000

208-230/1

18

30

17

100'

165'

5/8

3/8

PKA-A30KA

PUZ-A30NHA

30,000

21,000

23,000

208-230/1

25

40

15.5

100'

165'

5/8

3/8

PKA-A36KA

PUZ-A36NHA

34,200

23,940

25,000

208-230/1
25
M-Series or P-Series?

40

14

100'

165'

5/8

3/8

208-230/1
21
25
M-Series Wall Mounted Heat Pump

208-230/1
25
40
P-Series Wall Mounted Heat Pump

1. The P-Series can cool down to 0 deg F outdoor ambient and the M-Series can only go to 14 deg F.
2. The P-Series has longer line lengths than the M-Series for similar tonnages.
3. The P-Series has larger models for some indoor styles than the M-Series.
Notes

Low Ambient
Cooling
Condensate
Electrical

The M-Series can cool down to 14 deg F outdoor ambient. There is no low ambient kit for the M-Series. The P-Series can cool down to 0 deg F outdoor ambient with the Wind Baffle low ambient kit.
The Wall Mounted models do not come with an integral condensate pump. Any condensate pump with a float switch can be wired to stop operation when the condensate overflows.
The Mitsubishi mini-splits require a single point power connection at the outdoor unit. Three wires are then ran from the outdoor unit to the indoor unit carrying line voltage.

Mitsubishi Mini-Split Single Zone Systems


Ceiling Cassette
Systems

Indoor Unit

Outdoor Unit

Cooling Capacity

Heating Capacity

ODB 95, EAT 80/67

ODB 17, EAT 70

Total

Sensible

Voltage

Total

MCA
(Outdoor
Unit)

MOCP
(Outdoor
Unit)

Refrigerant Pipe
SEER
Max Height

Max Length

Gas Side OD Liquid Side


(in)
OD (in)

M-Series 2' X 2' Ceiling Cassette Heat Pump


SLZ-KA09NA

SUZ-KA09NA

8,400

6,720

6,200

208-230/1

12

15

15

40'

65'

3/8

1/4

SLZ-KA12NA

SUZ-KA12NA

11,100

8,436

8,300

208-230/1

12

15

15.4

40'

65'

3/8

1/4

SLZ-KA15NA

SUZ-KA15NA

15,000

12,000

10,200
208-230/1
12
15
P-Series 3' X 3' Ceiling Cassette Cooling-Only

16

40'

65'

1/2

1/4

PLA-A12BA

PUY-A12NHA

12,000

10,080

NA

208-230/1

13

15

13.5

100'

100'

1/2

1/4

PLA-A18BA

PUY-A18NHA

18,000

14,580

NA

208-230/1

13

20

14.2

100'

100'

1/2

1/4

PLA-A24BA

PUY-A24NHA

24,000

18,240

NA

208-230/1

18

30

13.6

100'

165'

5/8

3/8

PLA-A30BA

PUY-A30NHA

30,000

21,900

NA

208-230/1

25

40

13.6

100'

165'

5/8

3/8

PLA-A36BA

PUY-A36NHA

35,000

25,900

NA

208-230/1

25

40

14.2

100'

165'

5/8

3/8

PLA-A42BA

PUY-A42NHA

42,000

29,820

NA

208-230/1
26
40
P-Series 3' X 3' Ceiling Cassette Heat Pump

14.4

100'

165'

5/8

3/8

PLA-A18BA

PUZ-A18NHA

18,000

14,580

13,000

208-230/1

13

20

14.2

100'

100'

1/2

1/4

PLA-A24BA

PUZ-A24NHA

24,000

18,240

16,000

208-230/1

18

30

13.6

100'

165'

5/8

3/8

PLA-A30BA

PUZ-A30NHA

30,000

21,900

23,000

208-230/1

25

40

13.6

100'

165'

5/8

3/8

PLA-A36BA

PUZ-A36NHA

35,000

25,900

25,000

208-230/1

25

40

14.2

100'

165'

5/8

3/8

PLA-A42BA

PUY-A42NHA

42,000

29,820

30,000

208-230/1

26

40

14.4

100'

165'

5/8

3/8

M-Series or P-Series?

1. The P-Series can cool down to 0 deg F outdoor ambient and the M-Series can only go to 14 deg F.
2. The P-Series has longer line lengths than the M-Series for similar tonnages.
3. The P-Series has larger models for some indoor styles than the M-Series.
Notes
Low Ambient
Cooling
Access
Condensate
Electrical

The M-Series can cool down to 14 deg F outdoor ambient. There is no low ambient kit for the M-Series. The P-Series can cool down to 0 deg F outdoor ambient with the Wind Baffle
low ambient kit.
An 18" x 18" access panel is required for the SLZ models when installed in a hard lid ceiling
The M and P Series Ceiling Cassettes come with an integral condensate pump. The condensate pump includes a float switch that turns off the indoor unit and produces an error
code when the condensate overflows. The M-Series SLZ cassette has a lift of 19 11/16" from the ceiling up and the P-Series PLA cassette has a lift of 33 7/16" from the ceiling up.
The Mitsubishi mini-splits require a single point power connection at the outdoor unit. Three wires are then ran from the outdoor unit to the indoor unit carrying line voltage.

Mitsubishi Mini-Split Single Zone Systems


Ducted Systems

Indoor Unit

Outdoor Unit

Cooling Capacity

Heating Capacity

ODB 95, EAT 80/67

ODB 17, EAT 70

Total

Sensible

Voltage

Total

MCA
(Outdoor
Unit)

MOCP
(Outdoor
Unit)

Airflow (CFM)

Refrigerant Pipe

Max. ESP

SEER
Low-Med-Hi

(In. W.G.) Max Height Max Length

Liquid
Gas Side
Side OD
OD (in)
(in)

M-Series Ducted Heat Pump


SEZ-KD09NA

SUZ-KA09NA

8,100

6,480

6,700

208-230/1

12

15

15

194-247-317

0.2

40'

65'

3/8

1/4

SEZ-KD12NA

SUZ-KA12NA

11,500

8,740

9,000

208-230/1

12

15

16

247-317-388

0.2

40'

65'

3/8

1/4

SEZ-KD15NA

SUZ-KA15NA

14,100

11,280

11,900

208-230/1

12

15

15.5

353-441-529

0.2

40'

65'

1/2

1/4

SEZ-KD18NA

SUZ-KA18NA

17,200

13,588

13,100

208-230/1

14

15

17.5

423-529-635

0.2

50'

100'

1/2

1/4

P-Series Ducted Cooling-Only


PEA-A12AA

PUY-A12NHA

12,000

9,240

NA

208-230/1

13

15

13.8

247-317-388

0.2

100'

100'

1/2

1/4

PEA-A18AA

PUY-A18NHA

18,000

14,400

NA

208-230/1

13

20

14.3

423-529-635

0.2

100'

100'

1/2

1/4

PEAD-A24AA

PUY-A24NHA

24,000

16,320

NA

208-230/1

18

30

16

512-636-742

0.6

100'

165'

5/8

3/8

PEAD-A30AA

PUY-A30NHA

30,000

20,400

NA

208-230/1

25

40

15.5

618-742-883

0.6

100'

165'

5/8

3/8

PEAD-A36AA

PUY-A36NHA

35,000

26,250

NA

208-230/1

25

40

15

847-1024-1201

0.6

100'

165'

5/8

3/8

PEAD-A42AA

PUY-A42NHA

42,000

31,920

NA

208-230/1

26

40

13.8

1024-1254-1483

0.6

100'

165'

5/8

3/8

P-Series Ducted Heat Pump


PEA-A18AA

PUZ-A18NHA

18,000

14,400

13,000

208-230/1

13

20

14.3

423-529-635

0.2

100'

100'

1/2

1/4

PEAD-A24AA

PUZ-A24NHA

24,000

16,320

18,000

208-230/1

18

30

16

512-636-742

0.6

100'

165'

5/8

3/8

PEAD-A30AA

PUZ-A30NHA

30,000

20,400

23,000

208-230/1

25

40

15.5

618-742-883

0.6

100'

165'

5/8

3/8

PEAD-A36AA

PUZ-A36NHA

35,000

26,250

25,000

208-230/1

25

40

15

847-1024-1201

0.6

100'

165'

5/8

3/8

PEAD-A42AA

PUY-A42NHA

42,000

31,920

30,000

208-230/1

26

40

13.8

1024-1254-1483

0.6

100'

165'

5/8

3/8

M-Series or P-Series?

1. The P-Series can cool down to 0 deg F outdoor ambient and the M-Series can only go to 14 deg F.
2. The P-Series has longer line lengths than the M-Series for similar tonnages.
3. The P-Series has larger models for some indoor styles than the M-Series.
Notes
Low Ambient
Cooling
Access
Condensate
Electrical

The M-Series can cool down to 14 deg F outdoor ambient. There is no low ambient kit for the M-Series. The P-Series can cool down to 0 deg F outdoor ambient with the Wind Baffle
low ambient kit.
An 18" x 18" access panel is required for all ducted models when installed in a hard lid ceiling. The access panel should be placed 6" from the left-hand side when looking through the
return of the unit.
All Ducted models come with an integral condensate pump. The condensate pump includes a float switch that turns off the indoor unit and produces an error code when the condensate
overflows. The M-Series SEZ Ducted models have a lift of 21 11/16" from the bottom of the unit up and the P-Series PEA Ducted models have a lift of 21 11/16" for 1-1.5 ton units and
27 9/16" for 2-3.5 ton units from the bottom of the unit up.
The Mitsubishi mini-splits require a single point power connection at the outdoor unit. Three wires are then ran from the outdoor unit to the indoor unit carrying line voltage.

Mitsubishi Mini-Split Single Zone Systems


Ceiling Suspended
Systems

Indoor Unit

Outdoor Unit

Cooling Capacity

Heating Capacity

ODB 95, EAT 80/67

ODB 17, EAT 70

Total

Sensible

Voltage

Total

MCA
(Outdoor
Unit)

MOCP
(Outdoor
Unit)

Refrigerant Pipe
SEER
Max Height Max Length

Gas Side
OD (in)

Liquid Side
OD (in)

P-Series Ceiling Suspended Cooling-Only


PCA-A24KA

PUY-A24NHA

24,000

17,520

NA

208-230/1

18

30

16.8

100'

165'

5/8

3/8

PCA-A30KA

PUY-A30NHA

30,000

20,700

NA

208-230/1

25

40

14.5

100'

165'

5/8

3/8

PCA-A36KA

PUY-A36NHA

35,000

25,550

NA

208-230/1

25

40

14.4

100'

165'

5/8

3/8

PCA-A42KA

PUY-A42NHA

42,000

28,980

NA

208-230/1

26

40

15.8

100'

165'

5/8

3/8

P-Series Ceiling Suspended Heat Pump


PCA-A24KA

PUZ-A24NHA

24,000

17,520

18,000

208-230/1

18

30

16.8

100'

165'

5/8

3/8

PCA-A30KA

PUZ-A30NHA

30,000

20,700

23,000

208-230/1

25

40

14.5

100'

165

5/8

3/8

PCA-A36KA

PUZ-A36NHA

35,000

25,550

25,000

208-230/1

25

40

14.4

100'

165

5/8

3/8

PCA-A42KA

PUZ-A42NHA

42,000

28,980

30,000

208-230/1

26

40

15.8

100'

165

5/8

3/8

Notes
Low Ambient
Cooling

The P-Series can cool down to 0 deg F outdoor ambient with the Wind Baffle low ambient kit.

Condensate

The Ceiling Cassette models do not come with a condensate pump. An optional integral condensate pump is available, model PAC-SH84DM-E. The pump has a lift of 23 9/16"
from the top of the unit up.

Electrical

The Mitsubishi mini-splits require a single point power connection at the outdoor unit. Three wires are then ran from the outdoor unit to the indoor unit carrying line voltage.

Mitsubishi Mini-Split Single Zone Systems


h2i Hyper Heat
Inverter Units

Indoor Unit

Outdoor Unit

Cooling Capacity

Max Heating

ODB 95, EAT 80/67

Capacity @ ODB 5

Total

Sensible

Total

Voltage

MCA
(Outdoor
Unit)

MOCP
(Outdoor
Unit)

Refrigerant Pipe
SEER
Max Height

Max Length

Gas Side OD Liquid Side OD


(in)
(in)

M-Series Wall Mounted Heat Pump


MSZ-FE09NA

MUZ-FE09NA

9,000

6,840

10,900

208-230/1

12

15

26

40'

65'

3/8

1/4

MSZ-FE12NA

MUZ-FE12NA

12,000

8,760

12,500

208-230/1

12

15

23

40'

65'

3/8

1/4

MSZ-FE18NA

MUZ-FE18NA

18,000

15,120

21,600

20.2

50'

100'

5/8

3/8

PKA-A30KA

PUZ-HA30NHA2

30,000

21,000

32,000

40

16.5

100'

245

5/8

3/8

PKA-A36KA

PUZ-HA36NHA2

33,500

23,785

38,000

208-230/1
28
40
P-Series Ceiling Mounted Heat Pump

16.2

100'

245

5/8

3/8

PLA-A30KA

PUZ-HA30NHA2

30,000

21,900

32,000

40

16.5

100'

245

5/8

3/8

PLA-A36KA

PUZ-HA36NHA2

34,000

24,140

38,000

40

16.2

100'

245

5/8

3/8

PEAD-A30KA

PUZ-HA30NHA2

30,000

20,100

32,000

40

16.5

100'

245

5/8

3/8

PEAD-A36KA

PUZ-HA36NHA2

34,000

25,840

38,000

16.2

100'

245

5/8

3/8

PCA-A30KA

PUZ-HA30NHA2

30,000

20,700

32,000

208-230/1

40

16.5

100'

245

5/8

3/8

PCA-A36KA

PUZ-HA36NHA2

34,000

24,820

38,000

208-230/1
28
Hyper Heat or Standard?

40

16.2

100'

245

5/8

3/8

208-230/1
17.1
20
P-Series Wall Mounted Heat Pump
208-230/1

208-230/1

28

28

208-230/1
28
P-Series Ducted Heat Pump
208-230/1

28

208-230/1
28
40
P-Series Ceiling Suspended Heat Pump
28

1. Hyper Heat units are rated to operate in heating down to -13 F. They can operate down to -18 F and will auto restart when temperatures rise above -13 F.
2. Standard units are rated to operate in heating down to -5.
3. Hyper Heat units cost around 15% more for M-Series and 30% more for P-Series, but they can eliminate the need for backup heat.

Mitsubishi Mini-Split Single Zone Systems


Controls
Local Controllers

Model
Default Controller
Mounted
Installation Method

PAR-FL32MA-E

MHK1

MSZ / MSY

PKA / PLA / SLZ / PEA / SUZ

PAR-21MAA
-

Handheld

Wall Mounted

Wall Mounted

N/A

Wireless

Wired

User Functions

On/Off, Mode, Fan Speed, Air Flow Direction, Set Temp.

On/Off, Mode, Fan Speed, Air Flow Direction, Set Temp.

On/Off, Mode, Fan Speed, Air Flow Direction, Set Temp.

Dual Set Point

No

Yes

No

7-Day Programmable

No

Yes

Yes

Temperature Sensor Built In

No

Yes

Yes

Back-Lit

No

Yes

No

On/Off, Set Temp., Operation Mode, and Filter Sign

On/Off, Set Temp., and Operation Mode

On/Off, Set Temp., Operation Mode, and Filter Sign

Error Indication

None

Displays Error Code

Displays Error Code

Required Accessory for MSZ/MSY

None

None

MAC-397IF-E Contact Interface

Required Accessory for PKA

PAR-SA9CA-E Receiver

None

None

Required Accessory for SLZ

PAR-FA32MA-E Receiver

None

None

Required Accessory for PLA

PAR-SA9FA-E Receiver

None

None

Required Accessory for SEZ

PAR-FA32MA-E Receiver

None

None

Required Accessory for PEA

PAR-FA32MA-E Receiver

None

None

Required Accessory for PCA

PAR-SL93B

None

None

Permit/Prohibit Functions

BMS Integration
Partial Integration
Cost
User Control
User Monitor
Compatible BMS Integration
Installation Method
Required for MSZ / MSY / SLZ /
SEZ/
Required for PKA / PLA / PEA
PCA
BACnet Interface
LonWorks Interface

Full Integration

Less Expensive

More Expensive

On/Off

On/Off, Set Temp., Mode, Fan Speed, Air Flow Direction

Error/OK Status

Room Temp., Error Code, On/Off, Set Temp., Mode, Fan Speed, Air Flow Direction

Any BMS System that accepts relay inputs

BACnet and LonWorks

Through relays provided by others

Through City Multi M-Net and BMS Interface

MAC-397IF-E Contact Interface

MAC-399IF-E M-Net Interface

PAC-SF40RM-E Contact Interface

PAC-SF81MA-E

Not Applicable

BAC-HD150

Not Applicable

LMAP03U

Contacts