CONTENTS

THE SOLUTIONS
10

AUTOMATION SOLUTION
FOR 5 SHUTTERS
With BUS/SCS technology
With Zigbee technology

20

AUTOMATION SOLUTION
FOR 3 SHUTTERS AND 2 CURTAINS
With BUS/SCS technology
With Zigbee technology

31

LIGHT SCENARIO SOLUTION


With BUS/SCS technology
With Zigbee technology

50

LIGHT POINT ADDITION


SOLUTION
With Zigbee technology

56

SOUND DIFFUSION SOLUTION


1 SOURCE
With BUS/SCS technology

61

SOUND DIFFUSION SOLUTION


2 MULTICHANNEL SOURCES
With BUS/SCS technology

THE SOLUTIONS 3
WWW.BTICINO.COM

AUTOMATION OF CURTAINS AND SHUTTERS

To control the movement of one or more shutters/curtains


around the whole home. One single touch is enough to raise or
lower all the shutters/curtains of your home.

LIGHT SCENARIOS

Scenarios make life in your home much more


simple and comfortable thanks to the simultaneous
activation of several controls used daily.

THE ADVANTAGES

of theSOLUTIONS
Thanks to our solutions it is possible to add new devices
to the existing electric system, to expand and enrich the
functions of the traditional system.
This can be done using a wired or radio solution.

Thanks to the scenario control, the user can prepare


the room for relaxation, reading, watching a film, etc.
by ordering with a single movement the switching on
or off of certain lights.

SOUND DIFFUSION

To follow your favourite music program in each room of your


home with a high sound quality, with perfect look integration.

THE SOLUTIONS 5
WWW.BTICINO.COM

WIRED
BUS

SELECTION of the

TECHNOLOGY

WIRED BUS
The transmission of all information among
the devices added to the traditional electric
system is performed through a twisted pair
called BUS. The BUS cable transmits the
information and the power supply to the
devices and can be installed together with
the existing energy cables.
This solution is particularly suited for
new constructions, or when important
refurbishments have taken place.
6

RADIO
ZIGBEE

RADIO ZIGBEE
Thanks to the radio transmission
and the battery powering of controls,
the devices easily integrate with the
traditional electric system, without
the need for any additional wiring.
In this way the existing system can
be integrated with the automation of
lights and shutters.

THE SOLUTIONS 7
WWW.BTICINO.COM

GUIDE
to the

SOLUTIONS

PLANIMETRY FOR THE


POSITIONING OF THE DEVICES

DEVICE OPERATION DESCRIPTION

LOADS WHICH CAN BE DRIVEN

CONFIGURATION OF THE DEVICES

This document was


created as a guide for the
users, and to provide them
with all the necessary
information to enable
them to enrich the
electric system.
FUNCTIONAL DIAGRAM

LIST OF DEVICES THAT MUST BE ORDERED

Below are all the steps to


follow for the best possible
installation of the ready-made
solutions that we offer.

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

WIRING AND ACTIVATION


OF THE DEVICES

THE SOLUTIONS 9
WWW.BTICINO.COM

Automation solution for 5 shutters


with SCS BUS technology
Management of 5 motorized shutters or curtains using
individual controls and the general control.
This solution is particularly suited for new constructions
or refurbishments.

In case control of several loads is required (shutters or


curtains), or if several control points are to be installed,
system expansion is also possible.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio

Bedroom

Kitchen

Bathroom

Living Room

Hallway

Second
bathroom

Child
bedroom
2

Legend of symbols:
2

Distribution
board

10

Load control
(general control)

Flush mounted
actuator (single
control)

BUS - SCS cable 230 Vac cable

Shutter motor

Junction box

DEVICE OPERATION DESCRIPTION

Actuator device for SINGLE control:

GENERAL control device:

for local control of each individual associated/connected


shutter. The type of control depends on the configurator
connected to the M1 socket:
MONOSTABLE, press and hold down the top section
(shutter UP) or the bottom section (shutter DOWN) of the
key cover of the actuator device, until the desired shutter
position is reached.
BISTABLE, press and release the top section (shutter UP) or
the bottom section (shutter DOWN) of the key cover of the
actuator device. This will send an UP-DOWN command to
the shutter motor. After the command has been sent, press
the lower or upper key cover again to stop the shutter in
the desired position.

to control the opening or the closing of all shutters at the


same time. Configure the control for use in BISTABLE mode.

LOADS WHICH CAN BE DRIVEN

Power supply
from BUS

Description

Absorption
from BUS

Dissipated power
at maximum load

Relay

Type of load

C
Flush mounted 2 relay
actuator

18 27 Vdc

13.5 mA

0.9 W
NO NO

2 A 500 W

NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

CONFIGURATION OF THE DEVICES

Configurator
socket
Configurator

The configuration of the devices is performed by fitting


special components called configurators in appropriate
sockets identified by a number, letter, colour, or graphic
symbols.
To configure the devices refer to the FUNCTIONAL
DIAGRAM.

WARNING: the devices must only be configured when the system is


not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces

Description of the
configurators
Pull-out
handle

THE SOLUTIONS 11
WWW.BTICINO.COM

FUNCTIONAL DIAGRAM

N
L1

L2

N
L1

L2

N
L1

L2

N
L1

L2

L1

L2

N
230Vac
Vac L

Mini Power
supply

230Vac
Vac N
L

General
control

Single
control

Single
control

Single
control

Single
control

Single
control

1
2

BUS SCS 4

A1 = 5
PL1 = 1
M1 = (*)

A1 = GEN
M1 =

A1 = 5
PL1 = 2
M1 = (*)

A1 = 5
PL1 = 3
M1 = (*)

A1 = 6
PL1 = 1
M1 = (*)

A1 = 6
PL1 = 2
M1 = (*)

NOTE (*):configure M1= 8 for BISTABLE operation


configure M1= M for MONOSTABLE operation
configure M1= for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s.
Up-down to the end of stroke if the control is pressed for more than 1.5 s.

LIST OF DEVICES THAT MUST BE ORDERED

List of DIN module devices


Description

q.ty

BTicino

Legrand

Size (DIN)

Mini Power supply 230 Vac

E49

03567

2 modules

Power supply 110/127 Vac

346031

2 modules

TOTAL SIZE

2 modules

List of flush mounted devices


Description

q.ty

Residential series items


Livinglight

Axolute

Arteor

Cliane

Control for single and double loads

L4652/2

H4652/2

573974

67241

Flush mounted actuator 2 relays

LN4671M2

H4671M2

573961

67249

N4911M2AHN

HD4911M2AH

Key cover UP/DOWN 2 modules

NT4911M2AHN

HC4911/2AH

574384

68108

L4911M2AHN

HS4911/2AH

574385

68408

SCS-BUS cable

L4669

L4669

49231

49231

Configurator GEN

3501/GEN

3501/GEN

49210

49210

Configurator 1

3501/1

3501/1

49201

49201

Configurator 2

3501/2

3501/2

49202

49202

Configurator 3

3501/3

3501/3

49203

49203

Configurator 5

3501/5

3501/5

49205

49205

Configurator 6

3501/6

3501/6

49206

49206

Configurator 8

3501/8

3501/8

49208

49208

Configurator

3501/T

3501/T

49220

49220

3501/TM

3501/TM

49221

49221

Pull-out handle

3502

3502

49265

49265

Ring

Configurator

68083
68383

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

12

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM AND TRACING


OF THE CONDUITS

N
L

Actuator

L1

110 1)

Junction box

Actuator with key


cover for local
control

M
L2

2 A max
500 W max

Rear view

BUS

Control
A1
PL1
M1
A2
PL2
M2

110 1)

Rear view
Control device for the general
control of 5 shutters.

BUS

Vac

Mini Power supply

PRI

035 67
PRI: 220 240 V~
185 175 mA
47/63 Hz
SCS: 27 Vdc
600 mA

160 1)

SCS

Power
supply

Apartment
switchboard

BUS
Front view
NOTE 1): recommended height

NOTE: The size of the mini power supply is equal to 2 DIN modules and can be
installed in the electric control panel of the house together with a dedicated
thermal magnetic protection circuit breaker.

THE SOLUTIONS 13
WWW.BTICINO.COM

Automation solution for 5 shutters


with ZigBee technology
Using the Zigbee technology it is possible to add a
control point (e.g. a general control) to manage shutters,
by simply replacing the traditional devices with radio
devices, without the need to modify the existing wiring.

The new general control consists of a surface mounted


radio control.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio

Bedroom

Kitchen

Bathroom

Living Room

Hallway

Second
bathroom

Child
bedroom
2

Legend of symbols:
2

Distribution
board

Radio control
(general control)

Flush mounted radio


actuator (single control)

230 Vac
cable

Shutter motor

Junction box

DEVICE OPERATION DESCRIPTION

Single control radio actuator:


for local control of each individual associated/connected
shutter. The control type can be:
BISTABLE, press and release the top section (shutter UP) or
the bottom section (shutter DOWN) of the key cover of the
actuator device. This will send an UP-DOWN command to
the shutter motor. After activating the control, press the
bottom left key to stop the shutter in the desired position.
By pressing and holding down for more that one second
the UP or the DOWN keys, it is possible to adjust the
position of the blades.

General control:
for radio control of the opening or closing of all the
shutters at the same time. This is a BISTABLE type
control, the same as described for the single actuator.
UP control

STOP control

14

DOWN control

LOADS WHICH CAN BE DRIVEN

Description

Power supply / Frequency

Shutter motor

230 Vac@50/60 Hz

MAX 500 VA
MIN 270 VA

110 Vac@50/60 Hz

Max 250 VA
Min 135 VA

Radio actuator for shutter automations

CONFIGURATION OF THE DEVICES

The Configuration of radio ZigBee devices is performed


in three stages:

1 - Selection of the coordinator device and


network creation

1. Selection of the coordinator device and network

This is the first operation that must be completed after


wiring the devices. After its definition, the coordinator will
store all information relating to all the devices making up
the network, and will manage the transfer of information
among the devices.

creation. The coordinator device MUST be connected


to the electric power line.
2. Adding the devices to the network
3. Association of the devices
To help the reader, below is a legend of the symbols used
in the next pages to indicate the status of the LEDs of the
devices.

PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4

LED STATUS

seconds.

OFF
ON STEADY
FLASHING SLOWLY (1s)

4s

FLASHING QUICKLY (0.25s)


FLASHING (60ms)
FLASHING 3 TIMES (3s)
Coordinator

LEDS AND PUSHBUTTONS REQUIRED FOR THE


CONFIGURATION

NETWORK
pushbutton

NETWORK
indicator
LED

LEARNING
pushbutton

LEARNING
indicator
LED

3. The NETWORK LED (yellow) will come on steady, and


after a few instants will start flashing quickly.

Coordinator
ON/OFF control key

4. Create the network by setting the devices that will be


included, as indicated in the following page.

THE SOLUTIONS 15
WWW.BTICINO.COM

2 - Adding the devices to the network


3. To complete the procedure press the NETWORK KEY of
the Coordinator device; The corresponding NETWORK
LED will FLASH THREE TIMES, while the NETWORK
LEDs of all other devices will switch off.

1. Press the NETWORK KEY of the first device to include.


The NETWORK LED (yellow) turns on steady during
the network search stage. Once the stage has been
completed, it will start flashing quickly.

Coordinator

3s

Device

2. Repeat the above procedure for all devices to include


in the network.

Device

CHECKING THE DEVICES BELONGING TO THE NETWORK


To check the devices belonging to a common network
press the NETWORK KEY of any actuator device, or the
NETWORK KEY of the Coordinator device: the NETWORK
LED (yellow) of the Coordinator device will flash slowly,

while the NETWORK LEDs (yellow) of the other


Actuator devices will flash quickly. The controls
must be checked individually.

Device

16

Coordinator

Device

Device

PL

General control
1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly. Wait at least
1 second.
A

PL

5. Press the UP KEY (top right) on the same ACTUATOR,


the connected load activates and the shutter goes
UP. The LEARNING LED (green) will go from flashing
slowly to flashing quickly.

L2

PL

Control

3. Press the KEY (top right). The LEARNING LED (green)


will start flashing quickly.

Actuator

6. Repeat the operations at points 4 and 5 for all actuators


to associate to the general control.
7. Press the LEARNING KEY on the RADIO CONTROL.
The LEARNING LEDS (green) of all associated devices
will go off.

PL

PL

Control

4. Press the LEARNING KEY of the 1st ACTUATOR


(shutters), the LEARNING LED (green) will flash
slowly.

Control

L2

L2

Actuator
Actuator

THE SOLUTIONS 17
WWW.BTICINO.COM

FUNCTIONAL DIAGRAM

Motorized shutter
2

Flush mounted radio


actuator

General control
NOTE: Repeat the connection for all 5 shutters.

LIST OF DEVICES THAT MUST BE ORDERED

Description
1
2

Radio actuator for shutter


automation
Radio control for shutter
automation
Module key cover for actuator
and UP/DOWN control
Module key cover for actuator
and NEUTRAL control

q.ty
5
3

Residential series items

Livinglight
LN4595

Axolute
H4595

Arteor
573840
573841

N4599N (round cover plate) HA4599 (rectangular cover plate) 573842


L4599N (square cover plate) HB4599 (round cover plate) 573843
N4911AHN

HD4911AH

NT4911AHN

HC4911AH

L4911AHN

HS4911AH

N4911AN

HD4915

NT4911AN

HC4915

L4911AN

HS4915

supplied

supplied

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

18

Cliane
67263
67264
68100
68400
68081
68381

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM AND TRACING


OF THE CONDUITS

L2

Junction box
110 1)

Radio actuator

110 1)

Radio control

NOTA 1): recommended height


TV/SAT

IPTV

Maximum distances
The maximum distance between 2 devices is:
150 metres on free field.

automazione

15 metres for closed areas (the presence of masonry or


metal walls greatly reduces the signal strength).
antifurto

termoregolazione

videocitofonia

controllo

lan

controllo carichi

energia

luci

automazione
tvcc

www

irrigazione
antifurto

Wall
150 metres
15 metres
Radio control

Shutter
actuator

Radio control

Shutter
actuator

THE SOLUTIONS 19
WWW.BTICINO.COM

term

Automation solution for 3 shutters and 2 curtains


with SCS BUS technology
Management of 3 motorized shutters and 2 motorized
curtains, with individual controls and 2 independent
general controls. This solution is particularly suited for
new constructions or refurbishments.

In case control of several users is required (shutters or


curtains), or if several control points are to be installed,
system expansion is also possible.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio

Kitchen

Bedroom

Living
Room

Hallway

Second
bathroom

Bathroom
2

Child
bedroom
2

Legend of symbols:
2

Distribution
board

Load control
(comandi generali)

Flush mounted
actuator (single
control)

SCS - BUS
cable

230 Vac
cable

Shutter
motor

Curtains
motor

Junction box

DEVICE OPERATION DESCRIPTION

20

Actuator device for SINGLE control:

GENERAL control device:

for local control of each individual associated/connected


shutter/curtain. The type of control depends on the
configurator connected to the M1 socket:
MONOSTABLE, press and hold down the top section
(shutter/curtain UP) or the bottom section (shutter/
curtain DOWN) of the key cover of the actuator device,
until the desired shutter/curtain position is reached.
BISTABLE, press and release the top section (shutter/
curtain UP) or the bottom section (shutter/curtain DOWN)
of the key cover of the actuator device. This will send an
UP-DOWN command to the shutter/curtain motor. After
the command has been sent, press the lower or upper
key cover again to stop the shutter/curtain in the desired
position.

to control the opening or the closing of all shutters/


curtain at the same time. Configure the control for use in
BISTABLE mode.

LOADS WHICH CAN BE DRIVEN

Power supply
from BUS

Description

Absorption
from BUS

Dissipated power
at maximum load

Relay

Type of load

C
Flush mounted 2 relay
actuator

18 27 Vdc

13.5 mA

0.9 W
NO NO

2 A 500 W

NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

CONFIGURATION OF THE DEVICES

The configuration of the devices is performed by fitting


special components called configurators in appropriate
sockets identified by a number, letter, colour, or graphic
symbols.
To configure the devices refer to the FUNCTIONAL
DIAGRAM.

Configurator
socket
Configurator

WARNING: the devices must only be configured when the system is


not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces.

Description of the
configurators
Pull-out
handle

FUNCTIONAL DIAGRAM

N
L1

Vac NL
Vac N

L2

N
L1

L2

N
L1

L2

N
L1

L2

L1

L2

Mini Power
supply

General
control

BUS SCS

Single
control

Single
control

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

AMB
5

A1 = 5
PL1 = 1
M1 = (*)

Single
control

Single
control

A1 = 5
PL1 = 2
M1 = (*)

Single
control

A1 = 5
PL1 = 3
M1 = (*)

A1 = 6
PL1 = 1
M1 = (*)

A1 = 6
PL1 = 2
M1 = (*)

AMB
6

NOTE (*):configure M1= 8 for BISTABLE operation


Configure M1= M for MONOSTABLE operation
Configure M1= for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s.
Up-down to the end of stroke if the control is pressed for more than 1.5 s.

THE SOLUTIONS 21
WWW.BTICINO.COM

LIST OF DEVICES THAT MUST BE ORDERED

List of DIN module devices


Description

q.ty

BTicino

Legrand

Size (DIN)

Mini Power supply 230 Vac

E49

03567

2 modules

Power supply 110/127 Vac

346031

2 modules

TOTAL SIZE

2 modules

List of flush mounted devices


Description

q.ty

Residential series items


Livinglight

Axolute

Arteor

Cliane

Control for single and double loads

L4652/2

H4652/2

573974

67241

Flush mounted actuator 2 relays

LN4671M2

H4671M2

573961

67249

N4911M2AHN

HD4911M2AH

Key cover UP/DOWN 2 modules

NT4911M2AHN

HC4911/2AH

574384

68108

L4911M2AHN

HS4911/2AH

574385

68408

N4911AHM

HD4911AH

NT4911AHM

HC4911AH

574362

68100

L4911AH

HS4911AH

574363

68400

1 module UP/DOWN key

SCS-BUS cable

L4669

L4669

49231

49231

Configurator GEN

3501/GEN

3501/GEN

49210

49210

Configurator 1

3501/1

3501/1

49201

49201

Configurator 2

3501/2

3501/2

49202

49202

Configurator 3

3501/3

3501/3

49203

49203

Configurator 5

3501/5

3501/5

49205

49205

Configurator 6

3501/6

3501/6

49206

49206

Configurator 8

3501/8

3501/8

49208

49208

Configurator

3501/T

3501/T

49220

49220

3501/TM

3501/TM

49221

49221

Configurator AMB

3501/AMB

3501/AMB

49221

49221

Pull-out handle

3502

3502

49265

49265

Ring

Configurator

68083
68383

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

22

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM AND TRACING


OF THE CONDUITS

N
L

Actuator
L1

110 1)

Junction
box

Actuator with key


cover for local
control

M
L2

Rear
view

2 A max
500 W max

BUS

Control

110 1)

A1
PL1
M1
A2
PL2
M2

Rear
view

Control device
for the general
control of three
shutters and the
general control of
two curtains.

Apartment
switchboard

BUS

Vac

Mini Power
supply

PRI

035 67
PRI: 220 240 V~
185 175 mA
47/63 Hz
SCS: 27 Vdc
600 mA

SCS

160 1)

Power
supply

BUS

Front view
NOTE 1): recommended height

NOTE: The size of the mini power supply is equal to 2 DIN modules and can be
installed in the electric control panel of the house together with a dedicated
thermal magnetic protection circuit breaker.

THE SOLUTIONS 23
WWW.BTICINO.COM

Automation solution for 3 shutters and 2 curtains


with ZigBee technology
Using the Zigbee technology it is possible to add a control
point (e.g. a general control) to manage shutters and
curtains, by simply replacing the traditional devices with
radio devices, without the need to modify the existing wiring.

The new general control consists of a surface mounted


radio control.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Bedroom

Kitchen

Studio

Living
Room

Hallway

Second
bathroom

Bathroom
2

Child
bedroom
2

Legend of symbols:
2

Distribution
board

Load control
(general radio)

Flush mounted radio


actuator
(single control)

230 Vac
cable

Shutter
motor

Curtains
motor

Junction box

DEVICE OPERATION DESCRIPTION

Single control radio actuator:


for local control of each individual associated/connected
shutter. The control type can be:
BISTABLE, press and release the top section (shutter
UP) or the bottom section (shutter DOWN) of the
key cover of the actuator device. This will send an
UP-DOWN command to the shutter motor. After
activating the control, press the bottom left key to stop
the shutter in the desired position.
By pressing and holding down for more that one second
the UP or the DOWN keys, it is possible to adjust the
position of the blades.

24

General control:
for radio control of the opening or closing of all the
shutters at the same time. This is a BISTABLE type
control, the same as described for the single actuator.
UP
control

STOP
control

DOWN
control

LOADS WHICH CAN BE DRIVEN

Description

Power supply / Frequency

Shutter/Curtain motor

230 Vac@50/60 Hz

MAX 500 VA
MIN 270 VA

110 Vac@50/60 Hz

Max 250 VA
Min 135 VA

Radio actuator for shutter/curtain automations

CONFIGURATION OF THE DEVICES

The Configuration of radio ZigBee devices is performed


in three stages:

1 - Selection of the coordinator device and


network creation

1. Selection of the coordinator device and network

This is the first operation that must be completed after


wiring the devices. After its definition, the coordinator will
store all information relating to all the devices making up
the network, and will manage the transfer of information
among the devices.

creation. The coordinator device MUST be connected


to the electric power line.
2. Adding the devices to the network
3. Association of the devices
To help the reader, below is a legend of the symbols used
in the next pages to indicate the status of the LEDs of the
devices.

PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4

LED STATUS

seconds.

OFF
ON STEADY
FLASHING SLOWLY (1s)

4s

FLASHING QUICKLY (0.25s)


FLASHING (60ms)
FLASHING 3 TIMES (3s)
Coordinator

LEDS AND PUSHBUTTONS REQUIRED FOR THE


CONFIGURATION

NETWORK
pushbutton

NETWORK
indicator
LED

LEARNING
pushbutton

LEARNING
indicator LED

3. The NETWORK LED (yellow) will come on steady, and


after a few instants will start flashing quickly.

Coordinator
ON/OFF control key

4. Create the network by setting the devices that will be


included, as indicated in the following page.

THE SOLUTIONS 25
WWW.BTICINO.COM

2 - Adding the devices to the network


3. To complete the procedure press the NETWORK KEY of
the Coordinator device; the corresponding NETWORK
LED will FLASH THREE TIMES, while the NETWORK
LEDs of all other devices will switch off.

1. Press the NETWORK KEY of the first device to include.


The NETWORK LED (yellow) turns on steady during
the network search stage. Once the stage has been
completed, it will start flashing quickly.

Coordinator

3s

Device

2. Repeat the above procedure for all devices to include


in the network.

Device

CHECKING THE DEVICES BELONGING TO THE NETWORK


To check the devices belonging to a common network
press the NETWORK KEY of any actuator device, or the
NETWORK KEY of the Coordinator device: the NETWORK
LED (yellow) of the Coordinator device will flash slowly,

while the NETWORK LEDs (yellow) of the other


Actuator devices will flash quickly. The controls
must be checked individually.

Device

26

Coordinator

Device

Device

PL

General control for 3 shutters


1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly. Wait at least
1 second.
A

PL

5. Press the UP KEY (top right) on the same ACTUATOR,


the connected load activates and the shutter goes
UP. The LEARNING LED (green) will go from flashing
slowly to flashing quickly.

L2

PL

Control

3. Press the KEY (top right). The LEARNING LED (green)


will start flashing quickly.

Actuator

6. Repeat the operations at points 4 and 5 for all actuators


to associate to the general control.
7. Press the LEARNING KEY on the RADIO CONTROL.
The LEARNING LEDS (green) of all associated devices
will go off.

PL

PL

Control

4. Press the LEARNING KEY of the 1st ACTUATOR


(shutters), the LEARNING LED (green) will flash
slowly.

Control

L2

L2

Actuator
Actuator

THE SOLUTIONS 27
WWW.BTICINO.COM

General control for 2 curtains


1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly. Wait at least
1 second.
A

PL

5. Press the UP KEY (top right) on the same ACTUATOR,


the connected load activates and the curtains goes
UP. The LEARNING LED (green) will go from flashing
slowly to flashing quickly.

L2

PL

Control

3. Press the KEY (top right). The LEARNING LED (green)


will start flashing quickly.

Actuator

6. Repeat the operations at points 4 and 5 for all actuators


to associate to the general control.

PL

7. Press the LEARNING KEY on the RADIO CONTROL.


The LEARNING LEDS (green) of all associated devices
will go off.

Control

4. Press the LEARNING KEY of the 1st ACTUATOR


(curtains), the LEARNING LED (green) will flash slowly.

L2

Actuator

28

Control

L2

Actuator

PL

FUNCTIONAL DIAGRAM

Motorized
shutter

Flush mounted
actuator

Motorized
curtain

NOTE: Repeat the connection for all shutters


and curtains.

General shutter
control

General curtain
control

LIST OF DEVICES THAT MUST BE ORDERED

Description
1
2

Radio actuator for shutter


automation
Radio control for shutter
automation
Module key cover for actuator
and UP/DOWN control
Module key cover for actuator
and NEUTRAL control

q.ty
5
3

11

11

Residential series items

Livinglight
LN4595

Axolute
H4595

Arteor

Cliane

573840

67263

573841

N4599N (round cover plate) HA4599 (rectangular cover plate) 573842


L4599N (square cover plate) HB4599 (round cover plate)
N4911AHN

HD4911AH

NT4911AHN

HC4911AH

L4911AHN

HS4911AH

N4911AN

HD4915

NT4911AN

HC4915

L4911AN

HS4915

67264

573843

68100

supplied

68400
68081

supplied

68381

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

THE SOLUTIONS 29
WWW.BTICINO.COM

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM AND TRACING


OF THE CONDUITS

L2

Junction box
110 1)

Radio actuator

110 1)

Radio control

NOTA 1): recommended height


TV/SAT

IPTV

Maximum distances
The maximum distance between 2 devices is:
150 metres on free field.

15 metres for closed areas (the presence of masonry


or metal walls greatly reduces the signal strength).

automazione

antifurto

termoregolazione

videocitofonia

controllo

lan

controllo carichi

energia

luci

15 metres

30

Shutter
actuator

Radio control

www

Wall

150 metres

Radio control

automazione
tvcc

Shutter
actuator

irrigazione
antifurto

Light scenario solution with star wiring


and SCS BUS technology
The light scenario management solution makes it
possible to recreate the desired atmosphere.
Simply save light scenarios in the scenario module based
on the desired ambience (e.g. relax, reading, TV Vision,

wake-up), so that they may be recalled with a simple


movement using the Scenario Control device. Solution
realised with star wiring. All the actuators are in DIN
module.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio

Kitchen

Bedroom

D
E

B
F
Bathroom

Living Room

Hallway

Second
bathroom

Child
bedroom

Legend of symbols:

Distribution
board

Load control

Scenario
control

Lamp

BUS - SCS cable

230 Vac cable

Junction box

DEVICE OPERATION DESCRIPTION

Scenario module:

Scenario control:

it can be used to manage the scenarios created, modified


and activated using the scenario control.
Up to a maximum of 16 scenarios may be saved inside.

Its a device that gives the possibility of recalling, changing, or


modifying the scenarios saved in the Scenario Module.
With the scenario control it is possible to save up to 4
scenarios.

THE SOLUTIONS 31
WWW.BTICINO.COM

LOADS WHICH CAN BE DRIVEN

Description

2 relay
actuator

2 x 400 W
Multi load
Dimmer
Actuator

Power supply
from BUS

Absorption
from BUS

Dissipated power
at maximum load

28 MA
(SINGLE LOADS)

18 27 Vdc

100 - 240 Vac @


50/60 Hz

5 mA

Type of load

1.7 W

6 A / 1400 W (incandescence lamps and


energy saving halogens)
10 a / 2300 w (resistive loads)
1 a / 250 w (linear fluorescent lamps)
250 w max 4 lampade (compact fluorescent
lamps)
1 a / 250 w (electronic transformers)
2 a cos 0.5 / 500 va (ferromagnetic
transformers)

8W

1.7 A / 400 W (incandescence lamps and


energy saving halogens)
1.7 A / 400 W (electronic transformers)
1.7 A / 400 W (ferromagnetic transformers)

WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker
CONFIGURATION OF THE DEVICES

Configurator
socket
Configurator

WARNING: the devices must only be configured when the system is


not powered.
NOTE:
the reference code for the configurators is sold in kits of 10
pieces

Description of the
configurators
Pull-out
handle

Configurator

Pull-out
handle

Configurator
socket

32

The configuration of the devices is performed by fitting


special components called configurators in appropriate
sockets identified by a number, letter, colour, or graphic
symbols.
To configure the devices refer to the FUNCTIONAL
DIAGRAM.

FUNCTIONAL DIAGRAM

Vac L

N
Vac L

Mini Power
supply
Scenario
1
module

Dimmer
actuator

2 relay
actuator

2 relay
actuator

M
G2
PL2
G1
PL1
A

2 relay
actuator

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

ART.F420
ART.F411/2

F417U2

ON/+

ON/+

OFF/-

OFF/-

2x400 VA

2
A1 = PL1 = 1

Control

Control
5

A1
PL1
M1
A2
PL2
M2

A
PL1
G1
PL2
G2
M

=
=
=
=
=
=

GEN

O/I
1
1
O/I

AF
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

1
1
O/I
1
2
O/I

=
=
=
=
=
=

ART.F411/2

1 2 3 4
1 2 3 4
ART.F411/2

RL/C

A
PL1
PL2
G

=
=
=
=

2
1
2

A
PL1
PL2
G

=
=
=
=

3
1
2

A
PL1
PL2
G

=
=
=
=

4
1
2

1
1
2
-

Scenario
control

Control
C

A
PL
M
N
DEL

=
=
=
=
=

1
1(*)

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

2
1
O/I

Control
D

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

2
2
O/I

Control

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

3
1
O/I

Scenario
control

Control

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

3
2
O/I

A
PL
M
N
DEL

=
=
=
=
=

1
2(*)

Control
G

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

4
1
O/I

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

4
2
O/I

NOTE(*): by inserting the same configurator in M, the scenario


controls will activate the same scenarios.

THE SOLUTIONS 33
WWW.BTICINO.COM

LIST OF DEVICES THAT MUST BE ORDERED

List of DIN module devices


Description

q.ty

BTicino

Legrand

Size(DIN)

Mini Power supply 230 Vac

E49

03567

2 modules

Power supply 110/127 Vac

346031

2 modules

Scenario module

F420

03551

2 modules

2 x 400 W Multi load Dimmer Actuator

F417U2

02622

6 modules

2 relay actuator

F411/2

03842

6 modules

TOTAL SIZE

16 modules

List of flush mounted devices


Description

q.ty

Residential series items


Arteor

Cliane

Control for single and double loads 8

L4652/2

H4652/2

573974

67241

Scenario control

N4680
NT4680
L4680

HD4680
HC4680
HS4680

573902
573903

67217
67218

N4911AFN
NT4911AFN
L4911AFN

HD4911AF
HC4911AF
HS4911AF

574373 (left)
574372 (left)

68105 (left)
68405 (left)

N4911AIN
NT4911AIN
L4911AIN

HD4911AI
HC4911AI
HS4911AI

573964
573960
573965
573961

68264
68265
68564
68565

Key cover ON-OFF 2 modules

N4911/2AGN
NT4911/2AGN
L4911/2AGN

HD4911M2AG
HC4911/2AG
HS4911/2AG

574382
574383

68085
68385

BUS - SCS cable

L4669

L4669

49231

49231

Configurator GEN

3501/GEN

3501/GEN

49210

49210

Configurator 1

3501/1

3501/1

49201

49201

Configurator 2

3501/2

3501/2

49202

49202

Configurator 3

3501/3

3501/3

49203

49203

Configurator 4

3501/4

3501/4

49204

49204

Configurator 0/1

3501/01

3501/01

49216

49216

Pull-out handle

3502

3502

49265

49265

Ring

68083
68383

Key cover ON-OFF-GEN


regulation 1 module
Key cover ON-OFF regulation
1 module

Livinglight

Axolute

(left)
(right)
(left)
(right)

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

34

(left)
(right)
(left)
(right)

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

Control
ON
ON

ON

OFF

OFF

OFF

110 1)

Control
device for the
management
of lights.

Scenario
Dimmer light
control device control device

A1
PL1
M1
A2
PL2
M2

Rear view

BUS

Apartment
switchboard

Power supply
and DIN actuator

PRI

035 67
PRI: 220 240 V~
185 175 mA
47/63 Hz
SCS: 27 Vdc
600 mA

230 Vac

SCS

Mini Power
supply

160 1)

Front
view
NOTE 1): recommended height

BUS

NOTE: The size of the mini power supply is equal to 2 DIN modules and can be
installed in the electric control panel of the house together with a dedicated
thermal magnetic protection circuit breaker.

THE SOLUTIONS 35
WWW.BTICINO.COM

Procedure for programming a scenario:


1. In the scenario module press
the programming enable
pushbutton.

ART.F420
ART.F420

DEL

DEL

Procedure for deleting one or more scenarios:


In the scenario module press
the progr amming enable
pushbutton.

ART.F420
ART.F420

DEL

DEL

The corresponding LED turns


green: the module is enabled.

The corresponding LED turns


green: the module is enabled.

ART.F420
ART.F420

DEL

2. Press the key to program for


more than 4 seconds.

t > 4 sec.

When the LED turns on release


the key. The LED will start
flashing, confirming that the
programming mode is active.

ART.F420

DEL

ON

ON

OFF

ART.F420

DEL

3. Set the sequence of the


commands making up
the scenario.
ON

ON

OFF

4. Press the key to complete


programming.

.TR

4F

02

LE

To add, modify, or remove a command from the


scenario repeat the sequence.
ART.F420

DEL

ON

To activate the scenario


press the corresponding key.

ON
At the end of programming it is recommended to
disable the possibility of modifying the scenarios, using
the enable/disable pushbutton of the scenario module
(F420). The corresponding LED turns red

36

DEL

t > 8 sec.

Press and hold down the key for


the scenario to remove, waiting
for the LED to come on and then
to start FLASHING QUICKLY.
To cancel all the scenarios
stored in the scenario module
press the reset pushbutton of
the module.

Light scenario solution with distributed wiring


and SCS BUS technology
The light scenario management solution makes it possible
to recreate the desired atmosphere. Simply save light
scenarios in the scenario module based on the desired
ambience (e.g. relax, reading, TV Vision, wake-up), so that

they may be recalled with a simple movement using the


Scenario Control device. Solution created with distributed
wiring. Flush mounted actuators are used when possible.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio
Studio

Kitchen
Kitchen

Bedroom
Bedroom

D
E

B
F
Living
LivingRoom
Room

Bathroom
Bathroom

Hallway

Second
Second
bathroom
bathroom

Child
Child
bedroom
bedroom

Legend of symbols:

Distribution
board

Load control

Scenario
control

Lamp

BUS - SCS
cable

230 Vac
cable

Junction box

DEVICE OPERATION DESCRIPTION

Scenario module:

Scenario control:

it can be used to manage the scenarios created, modified


and activated using the scenario control. Up to a maximum
of 16 scenarios may be saved inside.

Its a device that gives the possibility of recalling, changing, or


modifying the scenarios saved in the Scenario Module. With
the scenario control it is possible to save up to 4 scenarios.

THE SOLUTIONS 37
WWW.BTICINO.COM

LOADS WHICH CAN BE DRIVEN

Description

2X400 W
Multiload
Dimmer
Actuator

Control
actuator

Power supply
from BUS

Absorption
from BUS

Dissipated power
at maximum load

28 MA
(SINGLE LOADS)

18 27 Vdc

18-27 Vdc

14 mA

Type of load

8W

6 a / 1400 w (incandescence lamps and


energy saving halogens)
10 a / 2300 w (resistive loads)
1 a / 250 w (linear fluorescent lamps)
250 w max 4 lampade (compact fluorescent
lamps)
1 a / 250 w (electronic transformers)
2 a cos 0,5 / 500 va (ferromagnetic
transformers)

8W

1.7 A / 400 W (incandescence lamps and


energy saving halogens)
1.7 A / 400 W (electronic transformers)
1.7 A / 400 W (ferromagnetic transformers)

WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker
CONFIGURATION OF THE DEVICES

Configurator
socket
Configurator

WARNING: the devices must only be configured when the system is


not powered.
NOTE:
the reference code for the configurators is sold in kits of 10
pieces.

Description of the
configurators
Pull-out
handle

Configurator

Pull-out
handle

Configurator
socket

38

The configuration of the devices is performed by fitting


special components called configurators in appropriate
sockets identified by a number, letter, colour, or graphic
symbols.
To configure the devices refer to the FUNCTIONAL
DIAGRAM.

FUNCTIONAL DIAGRAM

Vac N
L
A

Vac N

Mini Power
supply
1

Scenario Dimmer
module actuator

M
G2
PL2
G1
PL1
A

ART.F420

F417U2

ON/+

ON/+

OFF/-

OFF/-

2x400 VA

RL/C

A
PL1
G1
PL2
G2
M

2
A1 =
PL1 = 1

Control
7

1
1

Actuator/
Control

Control

Scenario
control

5
A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

=
=
=
=
=
=

GEN

O/I
1
1
O/I

A
AF
PL1
M1
A2
PL2
M2

B
=
=
=
=
=
=

1
1
O/I
1
2
O/I

Scenario
control

A
PL
M
N
DEL

=
=
=
=
=

1
1(*)

A
PL
M
N
DEL

=
=
=
=
=

D
Actuator/
Control

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

2
1
O/I

A1
PL1
M1
A2
PL2
M2

Actuator/
Control

=
=
=
=
=
=

2
2
O/I

A1
PL1
M1
A2
PL2
M2

G
Actuator/
Control

=
=
=
=
=
=

3
1
O/I

A1
PL1
M1
A2
PL2
M2

=
=
=
=
=
=

3
2
O/I

A1
PL1
M1
A2
PL2
M2

H
Actuator/
Control

=
=
=
=
=
=

4
1
O/I

A1
PL1
M1
A2
PL2
M2

Actuator/
Control

=
=
=
=
=
=

4
2
O/I

1
2(*)

NOTE(*): by inserting the same configurator in M, the scenario


controls will activate the same scenarios.

THE SOLUTIONS 39
WWW.BTICINO.COM

LIST OF DEVICES THAT MUST BE ORDERED

List of DIN module devices


Description

q.ty

BTicino

Legrand

Size(DIN)

Mini Power supply 230 Vac

E49

03567

2 modules

Power supply 110/127 Vac

346031

2 modules

Scenario module

F420

03551

2 modules

2 x 400 W Multi load Dimmer Actuator

F417U2

02622

6 modules

TOTAL SIZE

10 modules

List of flush mounted devices


Description

q.ty

Residential series items


Livinglight

Axolute

Arteor

Cliane

Flush mounted actuator/control

LN4671M2

H4671M2

573961

67249

Single and double load control

L4652/2

H4652/2

573974

67241

Scenario control

N4680
NT4680
L4680

HD4680
HC4680
HS4680

573902
573903

67217
67218

N4911AFN
NT4911AFN
L4911AFN

HD4911AF
HC4911AF
HS4911AF

574373 (left)
574372 (left)

68105 (left)
68405 (left)

N4911AIN
NT4911AIN
L4911AIN

HD4911AI
HC4911AI
HS4911AI

573964
573960
573965
573961

68264
68265
68564
68565

Key cover ON-OFF 2 modules

N4911/2AGN
NT4911/2AGN
L4911/2AGN

HD4911M2AG
HC4911/2AG
HS4911/2AG

574382
574383

68085
68385

BUS - SCS cable

L4669

L4669

49231

49231

Configurator GEN

3501/GEN

3501/GEN

49210

49210

Configurator 1

3501/1

3501/1

49201

49201

Configurator 2

3501/2

3501/2

49202

49202

Configurator 3

3501/3

3501/3

49203

49203

Configurator 4

3501/4

3501/4

49204

49204

Configurator 0/1

3501/01

3501/01

49216

49216

Pull-out handle

3502

3502

49265

49265

Ring

68083
68383

Key cover ON-OFF-GEN


regulation 1 module
Key cover ON-OFF regulation
1 module

(left)
(right)
(left)
(right)

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

40

(left)
(right)
(left)
(right)

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

Control
A1
PL1
M1
A2
PL2
M2

110 1)

Rear view

BUS

Scenario
control device

Apartment
switchboard

ON

ON

OFF

OFF

Dimmer light
control device

Power supply
and DIN actuator

PRI

035 67
PRI: 220 240 V~
185 175 mA
47/63 Hz
SCS: 27 Vdc
600 mA

230 Vac

SCS

Mini Power
supply

160 1)

Front view

NOTE 1): recommended height

BUS

NOTE: The size of the mini power supply is equal to 2 DIN modules and can
be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

THE SOLUTIONS 41
WWW.BTICINO.COM

Procedure for programming a scenario:


1. In the scenario module press
the programming enable
pushbutton.

ART.F420
ART.F420

DEL

DEL

Procedure for deleting one or more scenarios:


In the scenario module press
the progr amming enable
pushbutton.

ART.F420
ART.F420

DEL

DEL

The corresponding LED turns


green: the module is enabled.

The corresponding LED turns


green: the module is enabled.

ART.F420
ART.F420

DEL

2. Press the key to program for


more than 4 seconds.

t > 4 sec.

When the LED turns on release


the key. The LED will start
flashing, confirming that the
programming mode is active.

ART.F420

DEL

ON

ON

OFF

ART.F420

DEL

3. Set the sequence of the


commands making up the
scenario.
ON

ON

OFF

4. Press the key to complete


programming.

.TR

4F

02

LE

To add, modify, or remove a command from the


scenario repeat the sequence.
ART.F420

DEL

ON

To activate the scenario


press the corresponding key.

ON
At the end of programming it is recommended to
disable the possibility of modifying the scenarios, using
the enable/disable pushbutton of the scenario module
(F420). The corresponding LED turns red.

42

DEL

t > 8 sec.

Press and hold down the key


for the scenario to remove,
waiting for the LED to come
on and then to start FLASHING
QUICKLY.
To cancel all the scenarios
stored in the scenario module
press the reset pushbutton of
the module.

Light scenario solution with ZigBee technology


Using radio dimmer and radio scenario control actuators,
with the Zigbee technology it is possible to set light
scenarios depending on the desired ambiance (e.g. relax,
reading, watching TV, night).

The radio scenario control is capable of saving up to 4


scenarios maximum. Scenarios can also be recalled
using a remote control.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio
Kitchen

Bedroom

Bathroom

Hallway

Living Room
Second
bathroom

Child
bedroom

Legend of symbols:

Distribution
board

Radio actuator

Scenario radio
control

Lamp

230 Vac cable

DEVICE OPERATION DESCRIPTION

DIMMER radio actuator for light control:

Scenario management radio control:

for the local control of lamps and loads.Press and


release the ON key to enable the load at 66% of its power.
To increase the power at the maximum level, hold down
the key. Press and release the OFF key to enable the load
at 33% of its power. To decrease the power down to the
minimum level, hold down the key.

for the management of 4 scenarios, which can be saved


and recalled using the control itself, or a remote control.
Radio remote control:
with 4 pushbuttons for scenario control.

Press the left key to switch the load on and off.


ON and adjustment
pushbutton

Scenario 1

Scenario 2
Scenario 1
Scenario 2

ON

Scenario 3
Scenario 4
OFF

OFF and
ON/OFF
pushbutton adjustment
pushbutton

Scenario 3

Scenario 4

THE SOLUTIONS 43
WWW.BTICINO.COM

LOADS WHICH CAN BE DRIVEN

Power supply/
frequency

Description

Radio actuator
DIMMER

Incandescence
lamps

Halogen
lamps

Ferromagnetic
lamps

Electronic
transformers

230 Vac@50/60 Hz

MAX 300 W
MIN 60 W

MAX 300 W
MIN 60 W

MAX 300 W
MIN 60 W

MAX 300 W
MIN 60 W

110 Vac@50/60 Hz

Max 150 W
Min 60 W

Max 150 W
Min 60 W

Max 150 W
Min 60 W

Max 150 W
Min 60 W

CONFIGURATION OF THE DEVICES

The Configuration of radio ZigBee devices is performed


in three stages:

1 - Selection of the coordinator device and


network creation.

1. Selection of the coordinator device and network

This is the first operation that must be completed after


wiring the devices. After its definition, the coordinator will
store all information relating to all the devices making up
the network, and will manage the transfer of information
among the devices.

creation. The coordinator device MUST be connected


to the electric power line.
2. Adding the devices to the network.
3. Association of the devices.
To help the reader, below is a legend of the symbols used
in the next pages to indicate the status of the LEDs of the
devices.

PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4

LED STATUS

seconds.

OFF
ON STEADY
FLASHING SLOWLY (1s)

4s

FLASHING QUICKLY (0.25s)


FLASHING (60ms)
FLASHING 3 TIMES (3s)
Coordinator

LEDS AND PUSHBUTTONS REQUIRED FOR THE


CONFIGURATION

NETWORK
pushbutton

NETWORK
indicator
LED

LEARNING
pushbutton

LEARNING
indicator LED

3. The NETWORK LED (yellow) will come on steady, and


after a few instants will start flashing quickly.

Coordinator
ON/OFF control key

44

4. Create the network by setting the devices that will be


included, as indicated in the following page.

2 - Adding the devices to the network


3. To complete the procedure press the NETWORK KEY of
the Coordinator device; The corresponding NETWORK
LED will FLASH THREE TIMES, while the NETWORK
LEDs of all other devices will switch off.

1. Press the NETWORK KEY of the first device to include.


The NETWORK LED (yellow) turns on steady during
the network search stage. Once the stage has been
completed, it will start flashing quickly.

Coordinator

3s

Device

2. Repeat the above procedure for all devices to include


in the network.

Device

CHECKING THE DEVICES BELONGING TO THE NETWORK


To check the devices belonging to a common network
press the NETWORK KEY of any actuator device, or the
NETWORK KEY of the Coordinator device: the NETWORK
LED (yellow) of the Coordinator device will flash slowly,

while the NETWORK LEDs (yellow) of the other


Actuator devices will flash quickly. The controls
must be checked individually.

Device

Coordinator

Device

PL

Device

THE SOLUTIONS 45
WWW.BTICINO.COM

Configuration of the scenario functions


The scenario consists of the simultaneous activation of
several loads, with the objective of creating a specific
comfort situation. As an example, below is a description of
the procedure for creating a scenario for switching ON two
dimmer light points, one at 50% and one at 100% of its power.

Procedure:
1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the SCENARIO CONTROL,
the lEARNING LED (green) will flash slowly.

5. Press the ON KEY (bottom left) of the first DIMMER


ACTUATOR. THE LEARNING LED (green) will start
flashing quickly.
100 %

Scenario control

3. Press KEY 1; the LEARNING LED (green) will start


flashing quickly.

6. Press the LEARNING KEY of the second Dimmer


actuator. The LEARNING LED (green) will flash slowly.

Scenario control

4. Press the LEARNING KEY of the first DIMMER


ACTUATOR. The LEARNING LED (green) will flash
slowly.

7. Press the ON KEY (bottom left) of the second Dimmer


actuator. The LEARNING LED (green) will start flashing
quickly.

100 %

Dimmer actuator

46

8. Press and hold down the KEY (bottom right) until the
desired brightness value has been reached (e.g. 50%).
The LEARNING LED (green) will start flashing quickly.

50 %

9. Press the LEARNING KEY of the SCENARIO CONTROL.


The LEARNING KEY (green) of the DIMMER ACTUATORS
and of the SCENARIO CONTROL will switch off.

Scenario control

Dimmer actuator 1

Dimmer actuator 2

10. Check that the scenario has been programmed


correctly by switching all the lights off and pressing
pushbutton no. 1 of the SCENARIO CONTROL.
If correctly set, the lights will switch on at the level
set during the configuration procedure.
WWW.BTICINO.COM

THE SOLUTIONS 47

FUNCTIONAL DIAGRAM

Flush mounted radio


actuator dimmer

Flush mounted radio


actuator dimmer

Flush mounted radio


actuator dimmer

"

Radio remote control

Radio scenario control

LIST OF DEVICES THAT MUST BE ORDERED

Description

q.ty

Radio actuator DIMMER

Radio scenario control

Radio remote control

1 module light actuator


key cover DIMMER symbol
1 module light actuator
key cover NEUTRAL
1 module scenario control
key cover

Livinglight

Residential series items


Axolute

Arteor
573816

LN4593

H4593

N4589N (round cover plate)

HA4589 (square cover plate) 573848

L4589N (square cover plate)

HB4589 (round cover plate) 573849

3528N

3528N

N4911AIN

HD4911AI

NT4911AIN

HC4911AI

L4911AIN

HS4911AI

N4915N

HD4915BA

NT4915N

HC4915BA

L4915N

HS4915BA

N4911N

HD4911

NT4911N

HC4911

L4911N

HS4911

573817

573870
supplied

supplied

supplied

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

48

Cliane
67237
67240
573870
68265
68565
68081
68381
68081
68381

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

ON

OFF

110 1)

Junction
box

Radio light
actuator

Radio scenario control

TV/SAT

TV/SAT

IPTV

IPTV

Maximum distances
The maximum distance between 2 devices is:
150 metres on free field.

automazione

antifurto

termoregolazione

videocitofonia

controllo

lan

controllo carichi

energia

luci

15 metres for closed areas (the presence of masonry or


metal walls greatly reduces the signal strength).

automazione
tvcc

www

antifurto
irrigazione

termoregolazione

videocitofonia

controllo

lan

controllo carichi

energia

luci

tvcc

Wall
150 metres
15 metres

Radio control

Radio light
actuator

Radio light
actuator

THE SOLUTIONS 49
WWW.BTICINO.COM

www

ir

Solution for the addition of a light point


with ZigBee technology
The Zigbee technology gives the possibility of adding
a light point to manage the lighting of the room.
The traditional switch is replaced by a radio actuator.

The new light point consists of a radio control surface


mounted on the wall.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Bedroom

Kitchen

Studio

Living Room

Hallway

Second
bathroom

Bathroom

Child
bedroom

Legend of symbols:

Distribution
board

Radio actuator

Radio control

Lamp

230 Vac cable

DEVICE OPERATION DESCRIPTION

ON/OFF radio actuator for light control:


for the local control of lamps and loads
Radio control:
for ON/OFF control of a group of radio actuators.

50

Blank
plate

ON/OFF
pushbutton

LOADS WHICH CAN BE DRIVEN

Power supply/
frequency

Description

Radio actuator for


light automation

Incandescence
lamps

Halogen lamps

Ferromagnetic
lamps

Electronic
transformers

230 Vac@50/60 Hz

MAX 400 W
MIN 60 W

MAX 400 W
MIN 60 W

MAX 400 W
MIN 60 W

MAX 400 W
MIN 60 W

110 Vac@50/60 Hz

Max 200 W
Min 60 W

Max 200 W
Min 60 W

Max 200 W
Min 60 W

Max 250 W
Min 135 W

CONFIGURATION OF THE DEVICES

The Configuration of radio ZigBee devices is performed


in three stages:

1 - Selection of the coordinator device and


network creation.

1. Selection of the coordinator device and network

This is the first operation that must be completed after


wiring the devices. After its definition, the coordinator will
store all information relating to all the devices making up
the network, and will manage the transfer of information
among the devices.

creation. The coordinator device MUST be connected


to the electric power line.
2. Adding the devices to the network
3. Association of the devices
To help the reader, below is a legend of the symbols
used in the next pages to indicate the status of the
LEDs of the devices.

PROCEDURE:
1. Remove any key covers present.
2. Select the actuator device that will act as a Coordinator,
and press the corresponding NETWORK KEY for 4

LED STATUS

seconds.

OFF
ON STEADY
FLASHING SLOWLY (1s)

4s

FLASHING QUICKLY (0,25s)


FLASHING (60ms)
FLASHING 3 TIMES (3s)
Coordinator

LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION

3. The NETWORK LED (yellow) will come on steady, and


after a few instants will start flashing quickly.

NETWORK
indicator
LED

NETWORK
pushbutton

LEARNING
indicator LED

LEARNING
pushbutton

Coordinator

ON/OFF control key

4. Create the network by setting the devices that will be


included, as indicated in the following page.

THE SOLUTIONS 51
WWW.BTICINO.COM

2 - Adding the devices to the network


3. To complete the procedure press the NETWORK KEY of
the Coordinator device; The corresponding NETWORK
LED will FLASH THREE TIMES, while the NETWORK
LEDs of all other devices will switch off.

1. Press the NETWORK KEY of the first device to include.


The NETWORK LED (yellow) turns on steady during
the network search stage. Once the stage has been
completed, it will start flashing quickly.

Coordinator

3s

Device

2. Repeat the above procedure for all devices to include


in the network.

Device

CHECKING THE DEVICES BELONGING TO THE NETWORK


To check the devices belonging to a common network
press the NETWORK KEY of any actuator device, or the
NETWORK KEY of the Coordinator device: the NETWORK
LED (yellow) of the Coordinator device will flash slowly,

while the NETWORK LEDs (yellow) of the other


Actuator devices will flash quickly. The controls
must be checked individually.

Device

52

Coordinator

Device

Device

PL

3 - Association of the devices


1. If fitted, remove the key covers of the involved devices.
2. Press the LEARNING KEY of the RADIO CONTROL, the
LEARNING LED (green) will flash slowly.
A

5. Press the ON KEY (bottom right) on the ACTUATOR. The


load connected turns on, the LEARNING LED (green)
changes FLASHING mode, from slow to quick.

PL

PL

Control

3. Press the ON KEY (bottom right). The LEARNING LED


(green) will start flashing quickly.
NOTE: repeat the procedure described at points 2 and 3 for each
command to be associated to the actuator.

Actuator

6. Press the LEARNING KEY on the RADIO CONTROL. The


LEARNING LEDS (green) of all associated devices will
go off.

PL

PL

Control

4. Press the ACTUATOR TO Associate to the LEARNING


KEY. The LEARNING LED (green) will start flashing
slowly.

Control

Actuator

Actuator

THE SOLUTIONS 53
WWW.BTICINO.COM

7. The devices are now associated: to check


that the configuration procedure has been
performed correctly press the OFF KEY
on the radio control; the load connected
to the actuator should go off.
Otherwise repeat the association procedure
described.

PL

FUNCTIONAL DIAGRAM

2
1

Radio light Control

Flush mounted ON/OFF radio actuator

LIST OF DEVICES THAT MUST BE ORDERED

Residential series items


Description

54

q.ty

Light control ON/OFF radio actuator

Light radio control

1 module key cover for actuator and light control

Livinglight

Axolute

LN4590

H45920

N4596N (round cover plate)

HA4596 (square cover plate)

L4596N (square cover plate) HB4596 (round cover plate)


N4915AN

HD4915BA

NT4915AN

HC4915BA

L4915AN

HS4915BA

Arteor
573812
573813
573834
573835

supplied

Cliane
67231

67235

68110 (right)
68410 (right)

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

Junction
box
110 1)

Radio actuator
L

Radio control

Maximum distances

TV/SAT

The maximum distance between 2 devices is:


150 metres on free field.

automazione

antifurto

termoregolazione

videocitofonia

controllo

TV/SAT

IPTV

lan

controllo carichi

IPTV

15 metres for closed areas (the presence of masonry or


metal walls greatly reduces the signal strength).

energia

luci

automazione
tvcc

www

antifurto
irrigazione

termoregolazione

videocitofonia

controllo

lan

controllo carichi

energia

luci

tvcc

Wall
150 metres
15 metres

Radio control

Radio light
actuator

Radio light
actuator

THE SOLUTIONS 55
WWW.BTICINO.COM

www

ir

1 Source sound system solution


with SCS BUS technology
The 1 source sound system solution gives the possibility
of installing a sound system in the room, with the option
of following the favourite music program in each room,

with high sound quality. The installation is simple,


flexible, and fast.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio

Kitchen

Living
Room

Bedroom

Hallway

Second
bathroom

Bathroom

Child
bedroom

Legend of symbols:

Distribution
board

Amplifier

BUS - SCS
cable

Audio cable

Loudspeaker

DEVICE OPERATION DESCRIPTION

Flush mounted stereo amplifier:


it amplifies the stereo signal on the BUS and drives up to
two loudspeakers with impedance between 8 and 16 OHMs.
The front of the amplifier includes two pushbuttons, used
to switch the loudspeakers on/off (short pressure);
adjust the output volume (extended pressure);
cycle through the saved radio stations.
Radio Tuner:
its capable of receiving FM radio stations. The front
pushbuttons and the backlit display give the possibility of
adjusting the device, store radio stations in the memory,
display RDS messages and the tuned frequency. The
radio is fitted with an internal wire antenna. In case of
insufficient signal inside the building, a coaxial type
connection may be used. For the programming procedure
see the CD supplied with the product.

56

False ceiling mounted loudspeakers:


20 W power, diam. 10 cm, springs for easy fastening.

ON

OFF
Flush mounted stereo amplifier

CONFIGURATION OF THE DEVICES

The configuration of the devices is performed by fitting


special components called configurators in appropriate
sockets identified by a number, letter, colour, or graphic
symbols.
To configure the devices refer to the FUNCTIONAL
DIAGRAM.

Configurator
socket
Configurator

WARNING: the devices must only be configured when the system is


not powered.
NOTE:
the reference code for the configurators is sold in kits of 10
pieces

Description of the
configurators
Pull-out
handle

FUNCTIONAL DIAGRAM

LIVING ROOM

BEDROOM

Loudspeaker

Loudspeaker

Amplifier

ON

A
PF

= 1
= 1

Amplifier

ON

OFF

= 1
= 2

A
PF

OFF

Line
terminator

BUS

In/out wiring

230
Vac
Mini Power supply

Radio Tuner

PRI

346030
PRI: 220 - 240V~
185-175mA
50/60Hz
SCS A-V
SCS

27Vdc
600mA

SCS A-V

SCS

S
MEM

= 1
= 2

THE SOLUTIONS 57
WWW.BTICINO.COM

LIST OF DEVICES THAT MUST BE ORDERED

List of DIN module devices


Description

q.ty

BTicino

Legrand

Size(DIN)

Mini Power supply 230 Vac

346030

2 modules

Mini Power supply 110/127 Vac

346031

2 modules

Radio Tuner

F500N

03582

4 modules

TOTAL SIZE

6 modules

List of flush mounted devices


Description

Flush mounting amplifier


1 module Diffusion functions
key cover

1 module ON-OFF & adjustment


key cover

q.ty

Residential series items


Livinglight

Axolute

Arteor

Cliane

L4562

H4562

573976

67302

N4911BNF

HD4911BF

NT4911BNF

HC4911BF

573966 (right)

68263 (right)

L4911BNF

HS4911BF

573967 (right)

68563 (right)

N4911AIN

HD4911AI

NT4911AIN

HC4911AI

L4911AIN

HS4911AI

573964 (left)

68264 (left)

573965 (left)

68564 (left)

False ceiling mounted loudspeakers

L4566/10

L4566/10

573982

573982

BUS - SCS cable

336904

336904

573999

573999

Line terminator

3499

3499

3589

3589

Configurator 1

3501/1

3501/1

49201

49201

Configurator 2

3501/2

3501/2

49202

49202

Pull-out handle

3502

3502

49265

49265

Ring

68083
68383

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

58

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

ON

Amplifier

110 1)

OFF

Flush mounted
amplifier for the
management of
the sound source.

Rear view

BUS
Apartment
switchboard

BUS
PRI

Power supply
and radio tuner

035 67
PRI: 220 240 V~
185 175 mA
47/63 Hz
SCS: 27 Vdc
600 mA

SCS

Vac

Mini Power
supply

160 1)
Radio Tuner
Front
view
NOTE 1): recommended height

NOTE: The size of the mini power supply is equal to 2 DIN modules and can be
installed in the electric control panel of the house together with a dedicated
thermal magnetic protection circuit breaker.

THE SOLUTIONS 59
WWW.BTICINO.COM

Procedure for storing radio stations


The device gives the possibility of storing up to 10 radio
stations. As a rule, when the tuner is supplied no radio
stations are stored.
Quickly press and release the M pushbutton for the
selection of the position number where the station will
be stored.
The display shows the position where the station will
be saved (A).
Press the forward/back pushbuttons to tune the radio
to the desired frequency.
A

When changing the frequency, the number displayed will


start flashing, to indicate that the frequency currently
displayed is different from the stored frequency.
Once the desired station has been found, press and hold
the M pushbutton until the two LEDs start flashing.
Release the pushbutton. The radio station has now
been saved.
To save other stations repeat the same procedure.

60

2 multichannel sources sound system solution


with SCS BUS technology
The 2 multichannel sources sound system solution gives
the possibility of installing a sound system in the room,
with the option of selecting the favourite sound source,

and have different music played in different rooms, with


high sound quality. The installation is simple, flexible,
and fast.

PLANIMETRY FOR THE POSITIONING OF THE DEVICES

Studio

Bedroom

Kitchen

Bathroom
Living
Room

Hallway

Second
bathroom

Child
bedroom

Legend of symbols:

Distribution
board

Amplifier

RCA input

Loudspeaker

BUS - SCS cable

Audio cable

DEVICE OPERATION DESCRIPTION

Flush mounted stereo amplifier:


it amplifies the stereo signal on the BUS and drives up to
two loudspeakers with impedance between 8 and 16 OHMs.
The front of the amplifier includes two pushbuttons, used
to switch the loudspeakers on/off (short pressure);
adjust the output volume (extended pressure);
switch audio source;
cycle through the saved radio stations.

RCA input:
provides interfacing, and the possibility of adapting the
level of signal of an external source. The connection
with the external source is by means of two female RCA
connectors (red = right channel; white = left channel).
The knob is used to adjust the sensitivity of the input
signal. For optimum adjustment the corresponding LED
must flash.

Radio Tuner:
its capable of receiving FM radio stations. The front
pushbuttons and the backlit display give the possibility of
adjusting the device, store radio stations in the memory,
display RDS messages and the tuned frequency. The
radio is fitted with an internal wire antenna. In case of
insufficient signal inside the building, a coaxial type
connection may be used. For the programming procedure
see the CD supplied.

False ceiling mounted loudspeakers:


20 W power, diam. 10 cm, springs for easy fastening.

ON

OFF

Flush mounted
stereo amplifier

Status
notification
LED

Sensitivity
LED

Flush mounting
RCA input

THE SOLUTIONS 61
WWW.BTICINO.COM

CONFIGURATION OF THE DEVICES

The configuration of the devices is performed by fitting


special components called configurators in appropriate
sockets identified by a number, letter, colour, or graphic
symbols.
To configure the devices refer to the FUNCTIONAL
DIAGRAM.

Configurator
socket
Configurator

WARNING: the devices must only be configured when the system is


not powered.
NOTE: the reference code for the configurators is sold in kits of 10 pieces

Description of the
configurators
Pull-out
handle

FUNCTIONAL DIAGRAM

LIVING ROOM/STUDIO
Loudspeaker

Loudspeaker

ON

BEDROOM
Loudspeaker

ON

A = 1
PF = 1

OFF

OFF

BUS

ON

A = 1
PF = 2

Line terminator

Radio Tuner

OUT1

A
PF

OFF

= 2
= 1

Line terminator

Multichannel
matrix

OUT2

In/out wiring

Power supply

3
RCA input (*)

= 2
A
MEM

= 1
= 2

S1

WARNING(*): If the sound source connected to the RCA input is not battery
powered, the source insulator must be used (item 3495 BTicino, item 573988
Legrand).

62

S2

BUS

1
Vac

LIST OF DEVICES THAT MUST BE ORDERED

List of DIN module devices


Description

q.ty

BTicino

Legrand

Size(DIN)

Power supply 230 Vac

346000

63435

8 modules

Power supply 127 Vac

346001

573990

8 modules

Multichannel matrix

F441M

03584

10 modules

Radio Tuner

F500N

03582

4 modules

TOTAL SIZE

22 modules

List of flush mounted devices


Description

Flush mounting amplifier


1 module Diffusion functions
key cover
Key cover ON-OFF regulation
1 module

RCA input

q.ty
3
3

Residential series items


Livinglight

Axolute

Arteor

Cliane

L4562

H4562

573976

67302

N4911BFN

HD4911BF

NT4911BFN

HC4911BF

L4911BFN
N4911AIN

HS4911BF
HD4911AI

NT4911AIN

HC4911AI

L4911AIN

HS4911AI

N4560

HD4560

NT4560

HC4560

L4560

HS4560

573966 (right)

68263 (right)

573967 (right)

68563 (right)

573964 (right)

68264 (right)

573965 (right)

68564 (right)

573926
573927

67301 (dispositivo)
68261 (cover)
68561 (cover)

False ceiling mounted loudspeakers

L4566/10

L4566/10

573982

573982

BUS - SCS cable

336904

336904

573999

573999

Line terminator

3499

3499

3589

3589

Configurator 1
Configurator 2
Pull-out handle

1
1
1

3501/1
3501/2
3502

3501/1
3501/2
3502

49201
49202
49265

Ring

49201
49202
49265
68083
68383

NOTE:
- LIVINGLIGHT: white device
Tech colour device
anthracite device
- AXOLUTE:
white device
Tech colour device
anthracite device
- ARTEOR:
white device
Magnesium colour device
- Cliane:
white device
Titanium colour device
WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

THE SOLUTIONS 63
WWW.BTICINO.COM

WIRING AND ACTIVATION


OF THE DEVICES

PRESETTING OF SYSTEM
AND TRACING OF THE CONDUITS

110 1)

Amplifier

Rear view

BUS

ON

BUS

OFF

Flush mounted amplifier for the


management of the sound source
and RCA input device.

Multichannel
matrix

Radio Tuner
FM

160 1)

NOTE 1): recommended height

Apartment
switchboard

PRI

035 67
PRI: 220 240 V~
185 175 mA
47/63 Hz
SCS: 27 Vdc
600 mA

SCS

Power supply,
multichannel matrix,
and radio FM tuner

64

S1

Power supply

Procedure for storing radio stations


The device gives the possibility of storing up to 10 radio
stations. As a rule, when the tuner is supplied no radio
stations are stored.
Quickly press and release the M pushbutton for the
selection of the position number where the station will
be stored.
The display shows the position where the station will
be saved (A).
Press the forward/back pushbuttons to tune the radio
to the desired frequency.
A

When changing the frequency, the number displayed will


start flashing, to indicate that the frequency currently
displayed is different from the stored frequency.
Once the desired station has been found, press and hold
the M pushbutton until the two LEDs start flashing.
Release the pushbutton. The radio station has now
been saved.
To save other stations repeat the same procedure.

THE SOLUTIONS 65
WWW.BTICINO.COM

Our services

Numero Verde

OM

IZ

XXX-XXXXXX
800-293000

CONTACT OUR CUSTOMER SUPPORT CENTRES

BTicino provides its customers with technical support


and quotation services. The objective is to offer to our
customers a competent and fast service, working with
alongside them as partners capable of providing answers
to their needs, and helping them to select the best
solutions for their systems.

BTicino offers technical after sales service through


authorised centres. For the conditions of the technical
assistance service during the warranty period,
the costs (for services not covered by the warranty),
and the details of the closest CAT call this toll free
number: XXX-XXXXXX or go to the Technical Service
section of the Professionals Portal.
www.bticino.com

CU
ST

TO TAKE ADVANTAGE OF OUR SERVICES CALL THE TOLL


FREE NUMBER

MYHOME AUTOMATION
VIDEO DOOR ENTRY SYSTEM

BTicino S.p.A. si riserva il diritto di variare in qualsiasi momento i contenuti del presente
stampato e di comunicare, in qualsiasi forma e modalit, i cambiamenti apportati.

TO

GUIDA TECNICA 2012

MY HOME

Guida alla progettazione e allinstallazione

B[JPt$BMBCSJBt
$BNQBOJB

FFICIO REGIONALE
0153 ROMA
iale della Piramide Cestia, 1
al. C - 4 piano - int. 15/16
el. Q 06/5783495
ax 06/5782117

FFICIO REGIONALE
0040 S. MARIA LA BRUNA
ORRE DEL GRECO (NA)
ia dellIndustria, 22
el. Q 081/ 8479500
ax 081/ 8479510

JDJMJB

FFICIO REGIONALE
5125 CATANIA
ia G. Battista Grassi, 17/A
el. Q 095/7178883
ax 095/7179242

BSEFHOB

ARTEOR

MH12GT - Edizione 01/2012

FFICIO REGIONALE
9100 CAGLIARI
/o centro Commerciale I MULINI
iano Primo int. 1
ia Piero della Francesca, 3
ocalit Su Planu
el. Q 070/541356
ax 070/541146

CLIANE

11_70 esaeleR

MH12GT

Release 07_11

Project and installation guide

Project and installation guide

ARTEOR

11_70 esaeleR

Release 07_11

For more information see our guides.

Project and installation guide

Project and installation guide

66
CET ADIUG

CLIANE

E
OM
IZ

TRAINING CENTRES

WEBSITE

Always keep up to date thanks to our Professionals


Portal: there you will find all the relevant product news,
technical sheets, videos, and activities of BTicino.

TO

CU

ST

Attend training courses on BTicino systems and solutions:


see the training section of the website.

SOFTWARE E SERVIZI 67
WWW.BTICINO.COM

E
AD - EXCM12SFB/UK - Edition 04/2012

IZ

OM

CU
ST

BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate,
in any form and modality, the changes brought to the same.

TO
BTicino SpA
Via Messina, 38
20154 Milano - Italia
www.bticino.com

Das könnte Ihnen auch gefallen