Experion PKS

R430.3 Software Change Notice

EPDOC-X175-en-4303E
February 2015

Release 430.3

Document

Release

Issue

Date

EPDOC-X175-en-4303E

430.3

February 2015

Disclaimer
This document contains Honeywell proprietary information. Information contained herein is to be used solely
for the purpose submitted, and no part of this document or its contents shall be reproduced, published, or
disclosed to a third party without the express permission of Honeywell International Srl.
While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied
warranties of merchantability and fitness for a purpose and makes no express warranties except as may be stated
in its written agreement with and for its customer.
In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The information
and specifications in this document are subject to change without notice.
Copyright 2015 - Honeywell International Srl

www.honeywell.com

Contents
1 Introduction ............................................................................................................................................ 5
1.1 About the document ............................................................................................................................................ 6
1.1.1 Revision history ................................................................................................................................... 6
1.2 About Experion R430.3 ...................................................................................................................................... 7
1.2.1 Controllers and Tools resolved PARs .................................................................................................. 7
1.2.2 Common Components resolved PARs ................................................................................................. 8
1.2.3 Servers and Stations resolved PARs .................................................................................................... 9
1.2.4 Issues .................................................................................................................................................. 14
1.2.5 Limitations ......................................................................................................................................... 15
1.3 Before you begin .............................................................................................................................................. 16
1.3.1 Prerequisites ....................................................................................................................................... 16
1.3.2 Experion PKS R430.3 installation or upgrade checklist ................................................................... 16
1.3.3 Applicable nodes ............................................................................................................................... 16
1.3.4 Applicable modules ........................................................................................................................... 17
1.3.5 Supported controller migration paths ................................................................................................ 17
1.3.6 Verifying the present version ............................................................................................................. 18
1.3.7 Copying the Experion PKS R430.3 ................................................................................................... 18
1.4 Change impact .................................................................................................................................................. 20
1.4.1 Control change impact ....................................................................................................................... 20
1.4.2 Operational change impact ................................................................................................................ 20
1.4.3 Infrastructural change impact ............................................................................................................ 21

2 Experion PKS R430.3 installation ....................................................................................................... 23


2.1 Installing the point release on non-redundant server node ............................................................................... 24
2.2 Installing the point release on redundant server ............................................................................................... 27
2.2.1 Installing the point release on Server B ............................................................................................. 27
2.2.2 Installing the point release on Server A ............................................................................................. 30
2.3 Installing the point release on Experion Application Server/ Console/Flex/Console Extension station/
eServer/Premium Access clients ....................................................................................................................... 35
2.4 Installing the point release on ACE or SCE ..................................................................................................... 39
2.5 Migrating controllers ........................................................................................................................................ 42
2.5.1 Updating the firmware ....................................................................................................................... 42
2.5.2 Firmware revision .............................................................................................................................. 42

3 Experion PKS R430.3 removal ............................................................................................................ 45


4 Notices .................................................................................................................................................. 47
4.1
4.2
4.3
4.4

Documentation feedback .................................................................................................................................. 48


How to report a security vulnerability .............................................................................................................. 49
Support .............................................................................................................................................................. 50
Training classes ................................................................................................................................................. 51

CONTENTS

www.honeywell.com

1 Introduction

Related topics
About the document on page 6
About Experion R430.3 on page 7
Before you begin on page 16
Change impact on page 20

1 INTRODUCTION

1.1 About the document


The Software Change Notice describes the prerequisites, resolved PARs, applicable nodes, and steps to install/
uninstall the point release. Additionally, the SCN contains information about the change impact and additional
information for this point release. The latest version of this SCN is always available on the Honeywell Process
Solutions website.

1.1.1 Revision history

Version

Date

Description

November 2014

Initial version.

December 2014

Updated section 1.3.1.

December 2014

Updated ML Server version in section 1.3.1.

January 2015

Updated section 1.3.5.

February 2015

Updated section 1.3.5.

www.honeywell.com

1 INTRODUCTION

1.2 About Experion R430.3


Experion R430.3 addresses problems and/offers improvements requested since the release of Experion R430.2.
Attention

Controller firmware upgrade or migration is only required if the system is experiencing one or more problems
resolved in Section 1.2.1 Controller and Tools.
If you intend to upgrade or migrate controllers, ensure to contact HPS Migration helpdesk (MHD) at least four
weeks before you install the Experion PKS R430.3 point release.
Experion R430.3 Software Change Notice includes a prioritized Product Anomaly Reports (PARs) summary.
Please contact the Honeywell TAC for assistance if you observe issues not covered in this SCN.

1.2.1 Controllers and Tools resolved PARs


PAR

Subsystem

Description

Patch Name

1-2C30VPX

Control Builder-HART

On assigning the ST800 DD to AI channel, ST800


Not Applicable
device channel does not get listed in Synchronize
maintenance mode. Functionality of Maintenance
mode is not as intended, even if you change the value
of PVSOURCE to MAN, device does not change
status to Available for Maintenance.

1-1WLAF8S

Control Builder-HART

The Maintenance Mode feature is supported for ST


800 device, same support is needed for new devices.

Not Applicable

1-2QMSC33

I/O-PMIO

On loading PMIO HART IOP with channels


configured, the IOP stops responding.

Not Applicable

1-2L9TNO2*

SCM-Sequential Control
Module

After migrating Experion R301 to Experion R410,


Sequential Control Module (SCM) stops responding
in the last block on passing through Interrupt
Handler.

Not Applicable

1-3216DAX

Control Builder-System
Repository

System Repository cache does not allow concurrent


access to multiple reader clients, resulting in
performance issues.

Not Applicable

1-1CJWAQU

Control Builder-Listview

The Listview grid is not populated if you enter wild


Not Applicable
card characters in BlockType combo box.
Additionally, you cannot enter characters manually in
one attempt in BlockType combo box.

1-32EKX13*

Turbine Control

In SVPM_PID block there is no method to detect


maximum Process Value (PV) between PV1 and
PV2.

1-32DTMMI*

ModBus TCP
Infrastructure

Not Applicable

Not Applicable
PCDI Channel may fail on device switchover.

1-2TMVGBP*

Network-FTE Bridge

FTE status Display for FTEB node displays


Not Applicable
erroneous failures. On FTE tab, the address count
and node count are different than expected for system
configuration.

1-387VNPT

OPM-Interoperability

The installation of Experion PKS R410.5 Controller Not Applicable


Patch Controlled Release 1 takes more than one hour
to complete and you see a message displayed as
follows,Gathering required information.

1-2Z18MCB*

CF-Control Function

The TypeConvert block uses the same input union


structure and is unable to perform successful
initialization.

Not Applicable

1 INTRODUCTION

PAR

Subsystem

Description

Patch Name

1-389EDDB*

SIM-FFD

For the process completeness need to merge the


SIMFFD changes already done for UNISIMSIMFFD Project Special (R410.2) in Experion
release R410.6.

Not Applicable

1-39L3HRS*

C300 Controller

On changing MODE to single step in control recipe,


C300 controller stops responding.

Not Applicable

1-2USKQFZ

Control BuilderConfiguration Form

Importing latest Device Description files in Control


Builder fails.

Not Applicable

1-3DO00CT

CDA-Control Data Access There is a delay in server switchover, on the removal


of CNET cables from primary server.

1-37KXN75

Enterprise Model Builder

You face problems with EMDB/ERDB backups from Not Applicable


DB admin.

1-3EBF4CF*

I/O-Series C

CC-PAOH51 and CC-PAIH051 fails with no


response.

Not Applicable

1-3E9XZ8B

Control Builder

An error message is displayed on certain SCM, on


switching to the table view.

Not Applicable

1-3F9FGIP

CDA-Control Data Access System Repository logs overflow with notifications


related to PMD points.

Not Applicable

1-3ELCVIH

CDA-Control Data Access Backup System Repository loses synchronization


with primary.

Not Applicable

1-3EBPQQD

OPM-Upgrade Tool

Some readiness checks are missing for server B, on


migrating the cluster from R400.2 to R431.1 TP2.0
release.

Not Applicable

1-3EFPCBB*

Simulation environments

You cannot change the SIMCOMMAND using


APPDEVELOPER access level for SIM-ACE.

Not Applicable

1-30J55WA

Simulation environments

USO stops responding on saving IC, OL and


backtrack snapshots.

Not Applicable

1-2SIJTKB

SIM-FFD

Issues are seen on saving USO snapshot w.r.t


SIMFFD.

Not Applicable

1-3IVYNZL

INS-Experion Installer

R430.3 installation fails and displays the following


error unable to read the status file for
Comms_Changer.

Not Applicable

Not Applicable

* Requires firmware to be updated.

1.2.2 Common Components resolved PARs


PAR

Subsystem

Description of the problem

Patch Name

1-1RY56DF

System Management

On the Port status tab for C2960 CISCO switches


CANE Display, port 1 status is not displayed.

Not applicable

1-U16Q4K

HMIWeb TPN Details

The BADPVPR parameter fails to appear in the


HMIWeb TPN Detail for NIM RegPV and analog
input points.

Not applicable

1-3EPVYK9

INS-Experion Installer

An error message is displayed while installing


R430.2 cumulative patch on domain controller node.

Not applicable

1-3GFVVVJ

Safeview

SafeView configures Experion multi-window


command window slightly too tall, leaving white
space at the bottom of the command window.

Not applicable

www.honeywell.com

1 INTRODUCTION

PAR

Subsystem

Description of the problem

1-US9Q99

Safeview

In SafeView when two windows are configured as


always-on-top, and then one of those is dragged on
top of the other and then closed, the underlying
Display does not automatically refresh to clean up
the overlapping area.

1-3J7WC2B

Experion Station-Faceplate Experion TPS DIGCOMP faceplate may enter


infinite loop and Station may stop responding.

Patch Name
Not applicable

Not applicable

1.2.3 Servers and Stations resolved PARs


Station
PAR

Subsystem

Description

Patch Name

1-2YA12Y3

Alarm Pager

Notifications from pre-R410 DSA publishers do not


get paged on R410 subscribers.

Not applicable

1-2ZWUKGV

Alarm Pager

Emails generated by Alarm pager do not contain the


server machine name as part of the email subject.

Not applicable

1-2KWQ47Z

Console Station

Server logs are flooded with message


"dsnotifsync_silence() .. can only be called on a
cluster server or console station" on a system
without a Console Station license.

Not applicable

1-3GB5B1J

Console Station

In rare circumstances, acknowledging an alarm on a


Console Station does not cause the alarm to be
acknowledged on another Console Station.

Not applicable

1-2VKUPAN

Displays

If a channel or controller is enabled or disabled, it


may take up to 60 seconds before this change is seen
on the SCADA controllers Display that is open on
another station.

Not applicable

1-2WT851D

Displays

Printing options in syscfgoperadvanced.htm file are


working in reverse.

Not applicable

1-3GEKLPH

Displays

Associated parameter name for auxiliary parameters


is truncated on analog point detail Display.

Not applicable

1-3G8V8JL

Distributed Server
Architecture

On DSA subscriber, alarm aggregation from SCADA Not applicable


points to equipment point stops after schematic view
is opened.

1-3G99397

Equipment Manager

Pipeline Flow Snapshot can occasionally not load on


DSA subscriber after initial Tag Synchronization.

1-3H86HAZ

Licence Management

Secure Comms embedded and Windows count do not Not applicable


need scaling factor and require limits of 1023 & 1270
respectively.

1-3F56LNN

Notifications

Configuration Studio logon and lockout system


alarms incorrectly appear on the process alarm
summary.

1-2EQR3T5

Notifications

Alarm help faceplate does not show alarm conditions Not applicable
for status points.

1-2MQ9CMD

Notifications

Alarm condition is not automatically pre-selected on


the alarm help faceplate if the type case for
condition/block text in Experion and ACM does not
match exactly.

Not applicable

Not applicable

Not applicable

1 INTRODUCTION

PAR

10

Subsystem

Description

Patch Name

1-2QSHAJ9

Notifications

Alarm Help faceplate may show incorrect list of


conditions if there are points in the system with
similar names.

Not applicable

1-2SLZFQT

Notifications

Alarm Help faceplate shows conditions/boundaries


that are not configured in ACM.

Not applicable

1-30G9RSN

Notifications

Events from Assets are not displayed in Event


Summary when View Without Alarm permission is
given.

Not applicable

1-3268BKV

Notifications

Alarm tracker does not show alarms in an alarm


group for points that have been directly added to an
alarm group.

Not applicable

1-HJIEOJ

OPC/ODBC

PHD logs can fill with thousands of error messages


during history recovery of an Experion server.

Not applicable

1-ZXQDVD

OPC/ODBC

Introduce throttling into the ODBC driver to prevent


overload from queries made against all points.

Not applicable

1-2IDCJZ7

OPC/ODBC

GdaMngr may restart unexpectedly if it disconnects


from an OPC server.

Not applicable

1-2L438J9

OPC/ODBC

Parameter discovery is being attempted via the OPC


Advanced Client connection associated with a
SCADA OPC client channel.

Not applicable

1-3FDF25D

OPC/ODBC

Group marginal alarms are raised with a 'FAILED'


condition.

Not applicable

1-3F91IIH

OPC/ODBC

During point download or server failover events can


be generated indicating OPC SCADA client point
parameter values are chattering.

Not applicable

1-2Q4LR5V

Operational Applications

Alarm aggregation does not work for some


equipment as the AlarmAggregation attribute is not
defined correctly.

Not applicable

1-2G5YGYJ

PHD Integration

Experion Tag Sync Server may terminate


unexpectedly when background monitors TPS tags.

Not applicable

1-2UCAWQ9

PHD Integration

Experion Tag Sync Server to provide CM


engineering units to PHD if no block engineering
units are defined.

Not applicable

1-1PQEDWF

SCADA Interfaces

HC900 Set point trend may not be drawn if segment


1 is a RAMP and ramp type is RATE.

Not applicable

1-20Y1IH9

SCADA Interfaces

Implement transaction IDs for Modbus TCP to


improve robustness to communication delays.

Not applicable

1-3F60F7F

SCADA Interfaces

Parameters configured with 0 scan period may appear Not applicable


as stale.

1-3GEEIS3

SCADA Interfaces

After entering a new SP or OP value to a slow OPC


controller, station shows old value followed by the
new value.

Not applicable

1-3GEEITR

SCADA Interfaces

Values with quality 0xD8


(OPC_QUALITY_GOOD_LOCAL_OVERRIDE)
are shown as bad in station.

Not applicable

1-3GYNZW3

SCADA Interfaces

Old and new values are not being output in Enron


Modbus events for EFM Exports to FLOWCAL.

Not applicable

1-3GYNTOH

SCADA Interfaces

There is a rare chance that some EFM records may


Not applicable
not get exported if the meter's laying down of records
coincide with EFM collection.

www.honeywell.com

1 INTRODUCTION

PAR

Subsystem

Description

Patch Name

1-3GYNTLF

SCADA Interfaces

History start and end date in CFX only covers history Not applicable
fields and does not include audit log events.

1-3GYLZ89

SCADA Interfaces

After a meter has been disabled for more than a


single scheduled collection, on enabling, the meter
extra collections can be performed every minute for
some period of time, based on number of collections
missed.

Not applicable

1-3GYNTTR

SCADA Interfaces

EFM export to CSV may show extra significant


digits for field values that were of type REAL in the
meter.

Not applicable

1-3H8A9FT

Server Database
Engineering

Databld clearall def dataformat command clears


default value of width 16 to 0 in all the records.

Not applicable

1-3HAEHG9

Server Database
Engineering

Equipment which have inherent controllers in them


throws warnings during downloads.

Not applicable

1-3H8B21T

Server Database
Engineering

Databld throws error on performing export for


dataformat, if Data type configured as REAL8.

Not applicable

1-23WRRT1

TPS Interface

If TPN server automatic restart is triggered, Experion Not applicable


server fails over to backup.

1-31L53A3

TPS Interface

With the option All TPS alarms are monitored by


Not applicable
at least one experion station disabled, TPS alarms
do not get acknowledged automatically on the ESVT.

1-31VJXYP

Station

Station may stop responding following a script error Not applicable


after right clicking on an MS Excel worksheet loaded
in an Active X document element.

1-3G513MV

Station

Station does not annunciate alarms via the alarm light Not applicable
on Orion Console.

1-VL3WCU

Station

Plantscape displays loaded in Experion Station may


not respect DSPZoomingAllowed setting and appear
to scale incorrectly.

Not applicable

1-QDQ4UR

Station

Faceplates/popups launch via script in


OnPageComplete may not load, or may not be
managed by SafeView in multi window station.

Not applicable

1-1I0D4J1

Station

The first tab of point detail Display gets loaded in


Not applicable
different window when using back-forward toolbar in
Multiwindow station with multiple command zones.

1-35VLWYF

Station

Station reports missing background shape in the logs


when navigating to any HMIWeb Display.

Not applicable

1-3H1EQ7D

Station

Pan and zoom displays that contain nested shapes


may not show data values.

Not applicable

1-3FKJ1I5

Station

Attempt to write a string containing invalid format


specifier to HMIWeb log file from within display
script may cause HSCStationWindow to stop
working.

Not applicable

1-1013ZU1

Station

OnShapeLoad event may not fire on a shape after


calling SetCustomProperty.

Not applicable

1-2YDKLRT

Station

Tabbed Displays may not be available when


multiwindow station connects using auxilary
connection file.

Not applicable

1-3AGY5VR

Station

Faceplates sometimes appear without any titlebar


when using Tabbed Displays in Multi-Window
Station.

Not applicable

11

1 INTRODUCTION

PAR

12

Subsystem

Description

Patch Name

1-2DJXPRR

Station

Station menus are disabled once you pass a certain


Not applicable
hard coded threshold for the number of commands in
the toolbar file.

1-2PTB9IH

Faceplates/Popups

Occasionally more than one faceplate may get


invoked for the same point.

Not applicable

1-2WI8XNP

Faceplates/Popups

On nodes running multiple instances of single


window station, new faceplates may fail to launch
after a while.

Not applicable

1-3GTOXLP

Faceplates/Popups

Occassionally IKB/OEP keys don't work sometimes


in Single Window Station Faceplates.

Not applicable

1-1VIZF5L

Chart/Trend

Tabular history grid displays wider columns when a


Trend configured on 1280x1024 resolution is loaded
on screen with 1900x1200 resolution.

Not applicable

1-Y3ESAR

Printing

Need to give focus to display after launching a


faceplate for Print actions to work in single window
station.

Not applicable

1-30B20GT

Printing

The default footer refers to PrintTemplate.html when


using metafile printing method in station.

Not applicable

1-YF3SXX

Printing

Station must try to read the display background color Not applicable
from HKCU registry location before reading from
HKLM to allow an operator to choose their own
preferred color.

1-VHDOXD

Printing

Entries added to the Station.ini file to disable the


Alarm Bar and Status Bar print options do not work.

Not applicable

1-1C14VOX

Notification Presentation

Occasionally station stops responding on double


clicking events and tooltips shown on screen for less
than 1 second.

Not applicable

1-2I1758P

Notification Presentation

Shelved, suppressed or disabled alarm icon may not


print on printer.

Not applicable

1-3ED3HVP

HMIWeb Display Builder

In some cases custom property references in scripts


for display elements and shapes may not migrate
correctly.

Not applicable

1-1G2BAQP

HMIWeb Display Builder

Migrated HMIWeb displays containing combined


elements having an embedded image fail to load the
image when uncombined.

Not applicable

1-3H1KPBJ

HMIWeb Display Builder

Pan and Zoom displays containing alarm icons with


script data attached may result in script errors in the
thumbnail.

Not applicable

1-1VBW7V3

HMIWeb Display Builder

HMIWeb Display builder may stop responding when


navigating to the script data tab on a system with a
large number of points.

Not applicable

1-3H3FTA9

HMIWeb Display Builder

Roundness attribute for HMIWeb rounded rectangle


elements should be configurable via stylesheet.

Not applicable

1-15CEP1N

Keyboard

Alphanumerics on a faceplate may become noneditable after performing select and drag operation.

Not applicable

1-2RW99OX

eServer Standard Access

Page callup via eServer Standard Access may fail


after some period of time.

Not applicable

1-11QM24P

eServer Standard Access

Value specified for eServer URL in eServer Standard


Access Configuration panel does not take effect on
the system.

Not applicable

www.honeywell.com

1 INTRODUCTION

PAR

Subsystem

Description

Patch Name

1-19AD7AU

eServer Premium Access

Internet Explorer may stop working when attempting Not applicable


to login after timeout.

1-3GEG0C5

Quick Builder

After importing special symbols in ASCII code table


(like Celsius degree symbol), Quick Builder displays
them differently that are not recognizable.

Not applicable

1-3H6M7DD

Quick Builder

Part of the text displays are truncated when


configuring a universal modbus channel with port
type Terminal server.

Not applicable

1-3H6M7GZ

Quick Builder

Provide configuration for Transaction ID option for


Modbus.

Not applicable

1-3H6MDJB

Quick Builder

Some units for a few parameters of Bristol Babcock


and Bristol Babcock open BSI Controller are not
displayed in the property panel.

Not applicable

1-2FRF63X

Quick Builder

Paste item back from Excel must ask user


confirmation if the item already exists in the Quick
Builder.

Not applicable

1-3H6MDKP

Quick Builder

Export All items relevant to file typedoes not export Not applicable
some of the controllers and points when you have
equipments in your project.

1-37OTH0B

Quick Builder

Quick Builder Modbus controller definition doesn't


support use of non-default port number.

Not applicable

1-3AHE8C7

Quick Builder

Quick Builder cannot be launched after changing the


cluster from day light saving time to normal time.

Not applicable

1-3H6KX3T

Quick Builder

Importing top of equipment template points does not


update all relationships with multiple entries.

Not applicable

1-NCGHC1

Configuration Studio

Cannot see block/condition dropdown and cannot


load DAS configuration to DSA servers in different
subnet where multicast cannot reach.

Not applicable

1-3JXDLUR

HMIWeb Station General

Audible annunciations stop even if there are still


outstanding active alarms on a station when any
alarm is acknowledged from a different station.

Not applicable

Server
PAR

Subsystem

Description

Patch Name

1-3GEHDTJ

Operational Applications

Current value of Compressor Map Display


occasionally drifts to the (0,0) point despite history
not being recorded as these values.

Not applicable

1-3GYMPQ5

Server History

Exception History Manager process can sometimes


fail to restart successfully upon a failover.

Not applicable

1-3GYNTVF

SCADA Interfaces

Gas Quality and Composition logs output in FlowCal Not applicable


GQSOURCE format are stored in the incorrect
location and hence they will not be processed by
FlowCal.

1-3HA2TI7

OPC/ODBC

Decimal deadband values are rounded off on


validating group.

Not applicable

1-3HCA923

SCADA Interfaces

ANA point alarm limit 7 is not preserved during


upgrade to Experion R430, from pre R410.

Not applicable

13

1 INTRODUCTION

1.2.4 Issues
PARs

Subsystem

Description

1-388NOFF

System Management

Description: The following error message is displayed 810 times, if the


location containing the contents of the Experion_PKS_R430_X.zip file
exceeds 14 characters.
MsiGetProperty(CustomActionData) failed
Recovery: None.
Workaround: Acknowledge the error message by clicking OK and proceed
with the installation.

1-3E2990A

Quick Builder

Description: Quick Builder upload fails when alarm limit value is NaN.
Recovery: None.
Workaround: Use numeric values for alarm limit values.

1-3FSWFYF

Quick Builder

Description: It is not possible to have SCADA RTU and EMDB asset with
same names.
Recovery: None.
Workaround: Do not use the same name for asset and controller.

1-3IMPGMP

Honeywell
Communications
Interface

Description: tpndss.exe leaks memory following repeated OPC client


connection attempts when LCN connection is down.
Recovery: Enable LCN connection.
Workaround: Stop OPC client connection attempts to TPN Server when
LCN connection is down. OPC client connections will fail when TPN Server
has no LCN connection thus there is no purpose in attempting connection.

1-3HDCDNZ

HMIWeb Display
Builder

Description: Use of Convert scripts for Message zone prompts into Callouts
option in Bulk Display Migrator may result in incorrect script on the migrated
Displays. This option has been disabled in R430.3.
Recovery: Refer to the Priority Notification 2014-31, https://
www.honeywellprocess.com/library/support/notifications/Customer/
pn2014-31_bulk_display_migrator_issue_callout_script.pdf for further
details.
Workaround: None.

1-3IM128N

System Management

Description: Analysis of the FTEProvider process shows memory leak in


Microsoft code, and Microsoft has been engaged to analyze and diagnose the
memory leak. The leak is visible by observing the memory usage for the
FTEProvider.exe process in Windows Task Manager.
Recovery: Reboot the node when the memory usage of FTEProvider
becomes high enough to impact other processes running on the system.
Workaround: Same as the recovery.

1-3IOLFFF

System Management

Description: Analysis of the syncrep process displays memory leak in


Microsoft code, and Microsoft has been engaged to analyze and diagnose the
memory leak. The leak is visible by observing the memory usage for the
SYNCREP process in Windows Task Manager.
Recovery: Reboot the node when the memory usage of syncrep gets high
enough to impact other processes running on the system.
Workaround: Same as the recovery.

14

www.honeywell.com

1 INTRODUCTION

PARs

Subsystem

Description

1-3L3DW3G

Network-FTE

Description: FTE issue is observed during R430.2 patch installation after


applying cumulative patch R430.2 from R430.1. The Honeywell FTE Mux
Adapter does not have any IP address and the subnet mask does not allow any
values except 255.255.255.255. This is caused when the initial IP address of
the Yellow adapter is set to DHCP by the Initialization Media and is then
changed after Experion PKS installation is completed.
Recovery:None.
Workaround: This situation requires the Yellow adapter settings to be fixed
before the cumulative patch is installed. To determine if this issue exists, you
need to answer the following two questions.
1. Did this computer upgrade from R430.1 to R430.2 without any problems?
If Yes, continue with the migration to R430.3 point release.
2. Was the Honeywell Adapter configured to a fixed IP address from DHCP
after the initial installation was completed?
OR
Was the computer initialized without configuring the IP Address? If yes,
then the computer may become unstable after upgrade.
If the answer to question 2 is Yes or unknown, contact the Migration Help
Desk (MHD) for further assistance before migrating to R430.3.

1-33Y4ZQL

CTools

Description: CTools does not prevent C300 bricking when migrating to


R430.1.
Recovery: Contact TAC for support.
Workaround: You can refer to PN 2014-21 https://
www.honeywellprocess.com/library/support/notifications/Customer/
pn-2014-21-r430.1-c300-controller-migration-firmware-update-issue.pdf for
recommendations and actions.

1.2.5 Limitations
Point release removal
[

] Automatic

[ ] Can be done manually during next upgrade

[ ] Must be done manually before next upgrade

Localization
[ ] Not impacted [ ] Point release may contain strings in English. A Localization
version to be included in the next release.

] Needs localization support

Point release distribution


[

] Not limited

[ ] Limited

15

1 INTRODUCTION

1.3 Before you begin


1.3.1 Prerequisites
Experion PKS R430.3 can be installed on a node on which the following Experion release is installed:

Experion PKS R430.2


Experion PKS R430.1
Attention
Before installing this point release, enable Windows Firewall.
If you are migrating from R4xx or prior, then you MUST download and install the R430.1 Server Database Migration
Utility from the link https://www.honeywellprocess.com/library/support/software-downloads/Experion/Experion
%20PKS%20R430.1%20Server%20DB%20Utility.zip.
Starting R430.x ML Server versions are not forward or backward compatible, hence if you are using the Honeywell
ML Server interface, ensure that you upgrade to the appropriate ML Server version. Refer the following table for more
details.
ML Server Version

R430.1

R430.2

1.5.0.3

Yes

No

1.5.0.5

No

Yes

R430.3
No compatible version available.

1.3.2 Experion PKS R430.3 installation or upgrade checklist


Upgrading to Experion PKS R430.3
Task

Reference

Check the applicable nodes.

Refer to the section Applicable nodes in this SCN.

Install Experion PKS R430.3 on the applicable nodes.

Refer to the section Experion PKS R430.3 installation on


page 23 in this SCN.

1.3.3 Applicable nodes


This Experion PKS R430.3 is applicable for the following nodes.

16

Sl.No.

Node

Is Experion PKS R430.3


applicable?

Application Server (EAS)

Yes

Application Control Environment (ACE)

Yes

Application Control Environment TPN Connected (ACET)

Yes

Console Station (ES-C)

Yes

Console Station TPN Connected (EST)

Yes

Console Extension Station (ES-CE)

Yes

Experion Server (ESV)

Yes

eServer

Yes

Experion Server TPN Connected (ESVT)

Yes

10

Experion HiWay Gateway (EHG)

Yes

www.honeywell.com

1 INTRODUCTION

Sl.No.

Node

Is Experion PKS R430.3


applicable?

11

Experion Application node. (E-APP)

Yes

12

Flex Station (ES-F)

Yes

13

Simulation Control Environment (SCE)

Yes

1.3.4 Applicable modules


The Experion PKS R430.3 is applicable for the following modules.
Sl.No.

Module

Is Experion PKS R430.3


applicable?

Enhanced High-Performance Process Manager (EHPM)

Yes

C200E controller

Yes

C300 controller

Yes

Fieldbus Interface Module (FIM)

Yes

Fieldbus Interface Module (FIM) 4

Yes

Fieldbus Interface Module (FIM) 8

Yes

Fault Tolerant Ethernet Bridge Module (FTEB)

Yes

Experion Hiway Bridge (EHB)

Yes

IO Link Interface Module (IOLIM)

Yes

10

PROFIBUS Gateway Module (PGM) 2

Yes

1.3.5 Supported controller migration paths


The following controller migration paths to Experion PKS R430.3 are supported.
Item No.

Controller path

Experion R310.2 Controller Patch 1

Experion R310.3 Controller Patch 3

Experion R310.3 Controller Patch 4

Experion R310.3 Controller Patch 5

Experion R310.3 Controller Patch 6

Experion R310.3 Controller Patch 7

Experion R311.2 Controller Patch 1

Experion R311.2 Controller Patch 2

Experion R311.2 Controller Patch 3

10

Experion R311.3

11

Experion R311.3 Controller Patch 1

12

Experion R311.3 Controller Patch 2

13

Experion R311.3 Controller Patch 3

14

Experion R311.3 Controller Patch 4

15

Experion R311.3 Controller Patch 5

16

Experion R311.3 Controller Patch 6

17

Experion R311.3 Controller Patch 7

17

1 INTRODUCTION

Item No.

Controller path

18

Experion R400.1

19

Experion R400.1 Controller Patch 1

20

Experion R400.1 Controller Patch 2

21

Experion R400.1 Controller Patch 3

22

Experion R400.2

23

Experion R400.2 Controller Patch 1

24

Experion R400.2 Controller Patch 2

25

Experion R400.2 Controller Patch 3

26

Experion R400.2 Controller Patch 4

27

Experion R400.2 Controller Patch 5

28

Experion R400.2 Controller Patch 6

29

Experion R400.2 Controller Patch 7

30

Experion R400.2 Controller Patch 8

31

Experion R400.3

32

Experion R400.4

33

Experion R400.5

34

Experion R400.6

35

Experion R410.1

36

Experion R410 Controller Patch 3

37

Experion R410 Controller Patch 4

38

Experion R410.2

39

Experion R410.3

40

Experion R410.2 Rev2

41

Experion R410.4

42

Experion R410.5

43

Experion R430.1

44

Experion R430.2

1.3.6 Verifying the present version


To verify the present version
1

Using Notepad, open the ProductVersion.txt file located in the following path.
<%User selected path%>\Honeywell\Experion PKS (for example, C:\Program Files(X86)\Honeywell
\Experion PKS)

Verify the ProductVersion.txt for the following:


Ensure that the following lines are present. If the following lines are present, the node has the appropriate
product version to install this patch.

+Experion PKS R430.1 Support Media Install completed on MM/DD/ YYYY HH:MM:SS AM/PM
+Experion PKS R430.2 Install completed on MM/DD/ YYYY HH:MM:SS AM/PM

1.3.7 Copying the Experion PKS R430.3


Perform the following steps.

18

www.honeywell.com

1 INTRODUCTION

1. Copy the Experion_PKS_R430_3.zip file to a temporary folder on your hard disk.


2. Extract the Experion_PKS_R430_3.zip file.
3. Copy the extracted files to a temporary folder on your hard disk.
Attention
The character count for the location containing the contents of the zip file must not exceed 14 characters.
For example, when you copy the files to C:\temp\update the character count is 14.
For more information, refer to PAR 1-388NOFF under section Issues on page 14.
Note
If you have installed the Whitelisting application, ensure that you follow the procedure mentioned in the
Whitelisting guide prior to the patch installation.

19

1 INTRODUCTION

1.4 Change impact


Related topics
Control change impact on page 20
Operational change impact on page 20
Infrastructural change impact on page 21

1.4.1 Control change impact


Not applicable.

1.4.2 Operational change impact


Tera Term to replace HyperTerm
Starting with R430.3, HyperTerm/HyperTerminal emulator is discontinued and Tera Term terminal emulator is
included with Experion. You must use Tera Term for all terminal emulator needs, including communication with
Cisco switches. If HyperTerm is installed, discontinue its use and remove it from your system. Note the
following:

Experion supports Tera Term version 4.82.


Tera Term can be installed on any node that is used for configuring the FTE switches.
Tera Term is available on the Experion media set and can be installed based on requirement. It is not
automatically installed as part of Experion installation.
Tera Term is also available on Honeywell Process Solutions website for installation and use with previous
releases of Experion.

PAR 1-YF3SXX
The resolution of this PAR allows the printing preferences to be set for each user through the HKCU registry
setting.
The following registry settings if present takes preference over the settings in HKLM.
[HKEY_CURRENT_USER\Software\Wow6432Node\Honeywell\Station] "PrintMethod"="Metafile"
"PrintBackgroundColor"="Transparent"
PAR 1-2ZWUKGV
Alarm pager e-mail subject now contains the server machine name. This brings Experion R430 release in line
with earlier Experion releases.
PAR 1-2UCAWQ9
The Experion Tag Synchronization server now provides the Control Module's engineering units to PHD if no
Function Block engineering units are applicable or configured.
Previously if the engineering units were not applicable to the Function Block type or if the Function Block
engineering units were left blank, then the Experion Tag Synchronization server would have sent an empty
string to PHD as the engineering units.
PAR 1-ZXQDVD
Currently ODBC Driver lists all the TPS, Point Server and Remote points while querying the Flexible point
table. Remote points can now be excluded from the Flexible Point table query if required.

20

www.honeywell.com

1 INTRODUCTION

1.4.3 Infrastructural change impact


Not applicable.

21

1 INTRODUCTION

22

www.honeywell.com

2 Experion PKS R430.3 installation

Note
If you are using Experion Support and Maintenance (ESM) to install the point release on the Experion cluster, add
the point release to the ESM Server. For more information, refer to the Installation Builder User's Guide.

Related topics
Installing the point release on non-redundant server node on page 24
Installing the point release on redundant server on page 27
Installing the point release on Experion Application Server/ Console/Flex/Console Extension station/eServer/
Premium Access clients on page 35
Installing the point release on ACE or SCE on page 39
Migrating controllers on page 42

23

2 EXPERION PKS R430.3 INSTALLATION

2.1 Installing the point release on non-redundant server node


Attention
Installing Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.
Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool from
Start > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKS
Start-Stop Services Control Panel tool to stop all services manually.

To stop the services


1

Log on to the server using an account that is part of both the Windows Administrators and Product
Administrators group.
Attention
Ensure that you log on with the mentioned required privileges.

For systems with licensed QVCS only: Open the QVCS Manager application and complete the required
QVCS operations (for example: Check in, Check out, revert, and so on). Close the QVCS Manager
application manually.

Perform the following Checkpoint tasks.


a

Disable all Checkpoint tasks; click Stop for all the scheduled Checkpoint tasks.
Attention
Any currently executing Checkpoint tasks must be complete before continuing. Ensure that all the automatic
or manual Checkpoint Save tasks are complete.

b
c

Ensure that the Checkpoint share has replicated correctly to all the Console stations.
To verify the replication of the Checkpoint shares, check the Event Summary Display page on the
Station after the manual/auto Checkpoint Saves are completed for all controllers. If the Event
Summary Display page does not display any replication failure event, the replication is successful.

Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.
Attention
You must enable the services after completing the procedure.

Close all the running applications.

If RSLinx is installed, perform the following steps to stop RSLinx for systems using ControlNet.
On the desktop, right-click My Computer and select Manage.
The Computer Management window appears.
b Expand Services and Applications in the left pane.
c Click Services.
The list of services appears in the right pane.
d Perform the following steps.
a

1. Right-click RSLinx Classic and select Stop.


2. Right-click Harmony and select Stop.
Close the Computer Management window.

To install the point Release

24

To install, perform the following steps.

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

If you are using Experion Support and Maintenance (ESM) to install the point release, install the point
release from the ESM client. For more information, refer to the Installation Builder User's guide. If you
are not using ESM to install the point release, go to step b.
b Ensure that you are logged on using an account that is part of both the Windows Administrators and
Product Administrators group.
c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKS
R430.3 > supportsoftware.exe. If the installation is from the network then map the location where the
installer folder is located to the network drive.
a

Attention
1. In the command prompt, as an Administrator, type the following command.
net use <drive>: \\computername\share\<folder> (for example, net use Z: \\199.63.5.151\temp\Experion
PKS R430.3 )
Ensure that the path mapped (for example, \\199.63.5.151\temp\<point release>) has both Read and
Write permissions.
2. Type the user name and password (must be in quotes if there is a blank).
3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.
d

Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Control
dialog box is displayed, click Yes to continue.
The Welcome to Experion PKS Update Manager dialog box appears.
Click Install to start the Experion PKS R430.3 installation.
Attention

During the installation, when the system restarts, manually log on to the system with the required
credentials to continue with the installation.
If the installation is being performed from the network, after each system restart, map the drive to continue
the installation. To map the drive, perform the steps as given in the Attention of Step b.
You may see the following error message related to service which cause the installation to abort. Stop the
service manually after acknowledging the message and restart the installation.
Failed to stop <service name>. Installation will be aborted now.

Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

To validate the installation

To verify if the Experion PKS R430.3 is installed, perform the following steps:
a Using Notepad, open the ProductVersion.txt file located in the following path.
C:\Program Files(X86)\Honeywell\Experion PKS OR <User selected path>\Honeywell\Experion PKS.
b Verify the ProductVersion.txt for the following:
+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PM
If the above line is present, it indicates that the installation is successful.
Note
After Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that the
system is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, you
may also see previous Experion release references in the product info.

Post-installation tasks
1

Log on as a member of Windows Administrators and Product Administrators group.

Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.

Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must be
enabled.

25

2 EXPERION PKS R430.3 INSTALLATION

Enable all the Checkpoint tasks.

To update Common Components packages (optional step)


1

Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.
Attention
Note that these steps must be performed ONLY if you install an optional common component package after
installing Experion PKS R430.3. The steps must be performed to update the installed optional common component
package version to Experion PKS R430.3 version.

Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installer
Experion PKS R430.3.

Browse to the respective sub folder containing the common component packages folder.

Choose Start > All Programs > Accessories > Command Prompt.

Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.

In the Command Prompt, enter the path of the common components update with the update name and click
ENTER.

The common component update is installed. Updates to following common components are available.

AppTPSBase
Cl Server
AppTPSClient
AppTPSSolution
Experion Remote Native Window
Honeywell FTE MUX Driver
Experion GUS Display Builder
Experion GUS Display Runtime
Experion GUS Remote displays
Honeywell HCI Runtime
Honeywell IKB Service
Honeywell Redirection Manager
Honeywell SafeView
Honeywell Signon Manager
Honeywell System Management Runtime
Honeywell TPS Domain Console Configuration
Honeywell File Transfer - Client
Honeywell File Transfer - Server
Attention
SUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It is
mandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fix
KB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install the
Microsoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://
support2.microsoft.com/kb/2925489.

26

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

2.2 Installing the point release on redundant server


For redundant servers, you must first install the point release on Server B and then on Server A.

2.2.1 Installing the point release on Server B


Attention
Installing Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.
Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool from
Start > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKS
Start-Stop Services Control Panel tool to stop all services manually.

To stop services
1

Log on to the server using an account that is part of both the Windows Administrators and Product
Administrators group.
Attention
Ensure that you log on with the mentioned required privileges.

Confirm that Server A is primary.

If the servers are not synchronized, click Synchronize. The servers are synchronized.

Continue with the following steps on Server B.

Perform the following Checkpoint tasks.


a

Disable all Checkpoint tasks; click Stop for all the scheduled Checkpoint tasks.
Attention
Any currently executing Checkpoint tasks must be complete before continuing. Ensure that all the automatic
or manual Checkpoint Save tasks are complete.

Ensure that the CPBASE and Checkpoint shares have replicated correctly between Server B and Server
A.
c Ensure that the Checkpoint share has replicated correctly to all the Console stations.
d To verify the CPBASE and the replication of the Checkpoint shares, check the Event Summary Display
page on the Station after the manual/auto Checkpoint Saves are completed for all controllers. If the
Event Summary Display page does not display any replication failure event, the replication is
successful.
b

For systems with licensed QVCS only: Open the QVCS Manager application and complete the required
QVCS operations (for example: Check in, Check out, revert, and so on). Close the QVCS Manager
application manually.

Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.
Attention
You must enable the services after completing the procedure.

Perform the following steps to disable ERDB replication.


Open Configuration Studio.
b Select Administer Control Strategy Database. Perform the required steps to disable ERDB replication.
a

Perform the following steps to disable EMDB replication.


a
b

Open Configuration Studio.


Select Administer the System Database. Perform the required steps to disable EMDB replication.

27

2 EXPERION PKS R430.3 INSTALLATION

10 Close all the running applications.

The installer automatically stops most of the required Experion services. However, certain services that are
not stopped by the installer must be stopped manually.
Perform the following steps to manually stop Experion services.
Click Start > Programs > Honeywell > Experion PKS > Server > Start-Stop Experion PKS Server
window.
b Select Database Unloaded in Full mode.
c Close the Start-Stop Experion PKS Server window.
a

Perform the following steps to stop RSLinx for systems using ControlNet.
On the desktop, right-click My Computer and select Manage.
The Computer Management window appears.
b Expand Services and Applications in the left pane.
c Click Services.
The list of services appears in the right pane.
d Perform the following steps.

1. Right-click RSLinx Classic and select Stop.


2. Right-click Harmony and select Stop.
Close the Computer Management window.

To install the point Release

To install, perform the following steps.


If you are using Experion Support and Maintenance (ESM) to install the point release, install the point
release from the ESM client. For more information, refer to the Installation Builder User's guide. If you
are not using ESM to install the point release, go to step b.
b Ensure that you are logged on using an account that is part of both the Windows Administrators and
Product Administrators group.
c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKS
R430.3 > supportsoftware.exe. If the installation is from the network then map the location where the
installer folder is located to the network drive.
a

Attention
1. In the command prompt, as an Administrator, type the following command.
net use <drive>: \\computername\share\<folder> (for example, net use Z: \\199.63.5.151\temp\Experion
PKS R430.3 )
Ensure that the path mapped (for example, \\199.63.5.151\temp\<point release>) has both Read and
Write permissions.
2. Type the user name and password (must be in quotes if there is a blank).
3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.
d

28

Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Control
dialog box is displayed, click Yes to continue.
The Welcome to Experion PKS Update Manager dialog box appears.
Click Install to start the Experion PKS R430.3 installation.

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

Attention

During the installation, when the system restarts, manually log on to the system with the required
credentials to continue with the installation.
If the installation is being performed from the network, after each system restart, map the drive to continue
the installation. To map the drive, perform the steps as given in the Attention of Step b.
You may see the following error message related to service which cause the installation to abort. Stop the
service manually after acknowledging the message and restart the installation.
Failed to stop <service name>. Installation will be aborted now.

Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

To validate the point release installation

To verify if the Experion PKS R430.3 is installed, perform the following steps:
Using Notepad, open the ProductVersion.txt file located in the following path.
C:\Program Files(X86)\Honeywell\Experion PKS OR <User selected path>\Honeywell\Experion PKS.
b Verify the ProductVersion.txt for the following:
+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PM

If the above line is present, it indicates that the installation is successful.


Note
After Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that the
system is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, you
may also see previous Experion release references in the product info.

Post-installation tasks
1

Log on as a member of Windows Administrators and Product Administrators group.

Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.

If the servers are not synchronized, click Synchronize. The servers are synchronized.

Click Manual Failover. The server failover takes place.


Attention
Server B becomes primary.

Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must be
enabled.

To update Common Components packages (optional step)


1

Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.
Attention
Note that these steps must be performed ONLY if you install an optional common component package after
installing Experion PKS R430.3. The steps must be performed to update the installed optional common component
package version to Experion PKS R430.3 version.

Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installer
Experion PKS R430.3.

Browse to the respective sub folder containing the common component packages folder.

Choose Start > All Programs > Accessories > Command Prompt.

Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.

In the Command Prompt, enter the path of the common components update with the update name and click
ENTER.

29

2 EXPERION PKS R430.3 INSTALLATION

The common component update is installed. Updates to following common components are available.

AppTPSBase
Cl Server
AppTPSClient
AppTPSSolution
Experion Remote Native Window
Honeywell FTE MUX Driver
Experion GUS Display Builder
Experion GUS Display Runtime
Experion GUS Remote displays
Honeywell HCI Runtime
Honeywell IKB Service
Honeywell Redirection Manager
Honeywell SafeView
Honeywell Signon Manager
Honeywell System Management Runtime
Honeywell TPS Domain Console Configuration
Honeywell File Transfer - Client
Honeywell File Transfer - Server
Attention
SUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It is
mandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fix
KB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install the
Microsoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://
support2.microsoft.com/kb/2925489.

2.2.2 Installing the point release on Server A


Attention
Installing Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.
Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool from
Start > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKS
Start-Stop Services Control Panel tool to stop all services manually.

To stop the services


1

Log on to the server using an account that is part of both the Windows Administrators and Product
Administrators group.
Attention
Ensure that you log on with the mentioned required privileges.

30

Confirm that Server B is primary.

If the servers are not synchronized, click Synchronize. The servers are synchronized.

Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

Attention
You must enable the services after completing the procedure.
5

Turn off file replication of the mapping files .


In Station, click Configure > File Replication. Do not change the Send check box in this display.
b Click mapping entry.
The configuration page for mapping file replication entry appears.
c Clear Replicate files from this path check box.
d Click Save.

Close all the running applications.


The installer automatically stops most of the required Experion services. However, certain services that are
not stopped by the installer must be stopped manually.
Perform the following steps to manually stop Experion services.
Click Start > Programs > Honeywell > Experion PKS > Server > Start-Stop Experion PKS Server
window.
b Select Database Unloaded in Full mode.
c Close the Start-Stop Experion PKS Server window.

Disable the Experion PKS Server System service. To disable the Experion PKS Server System service,
perform the following steps.
Choose Start > All Programs > Accessories > Command Prompt.
Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.
c In the Command Prompt, type the following command sc config HSCSERVER_System start= disabled
and click ENTER (the command must have a space after the equal sign).
d Ensure that you see the following message once the Experion PKS Server System service is disabled
successfully [SC] ChangeServiceConfig SUCCESS.

Perform the following steps to stop RSLinx for systems using ControlNet.
On the desktop, right-click My Computer and select Manage.
The Computer Management window appears.
b Expand Services and Applications in the left pane.
c Click Services.
The list of services appears in the right pane.
d Perform the following steps.
a

1. Right-click RSLinx Classic and select Stop.


2. Right-click Harmony and select Stop.
Close the Computer Management window.

To install the point Release

To install, perform the following steps.


If you are using Experion Support and Maintenance (ESM) to install the point release, install the point
release from the ESM client. For more information, refer to the Installation Builder User's guide. If you
are not using ESM to install the point release, go to step b.
b Ensure that you are logged on using an account that is part of both the Windows Administrators and
Product Administrators group.
c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKS
R430.3 > supportsoftware.exe. If the installation is from the network then map the location where the
installer folder is located to the network drive.
a

31

2 EXPERION PKS R430.3 INSTALLATION

Attention
1. In the command prompt, as an Administrator, type the following command.
net use <drive>: \\computername\share\<folder> (for example, net use Z: \\199.63.5.151\temp\Experion
PKS R430.3 )
Ensure that the path mapped (for example, \\199.63.5.151\temp\<point release>) has both Read and
Write permissions.
2. Type the user name and password (must be in quotes if there is a blank).
3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.
d

Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Control
dialog box is displayed, click Yes to continue.
The Welcome to Experion PKS Update Manager dialog box appears.
Click Install to start the Experion PKS R430.3 installation.
Attention

During the installation, when the system restarts, manually log on to the system with the required
credentials to continue with the installation.
If the installation is being performed from the network, after each system restart, map the drive to continue
the installation. To map the drive, perform the steps as given in the Attention of Step b.
You may see the following error message related to service which cause the installation to abort. Stop the
service manually after acknowledging the message and restart the installation.
Failed to stop <service name>. Installation will be aborted now.

Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.
g Start the Experion PKS Server System service. To start the Experion PKS Server System service,
perform the following steps.
f

1. Choose Start > All Programs > Accessories > Command Prompt.
2. Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to
continue.
3. In the Command Prompt, type the following command sc config HSCSERVER_System start= auto
and click ENTER (the command must have a space after the equal sign).
4. Ensure that you see the following message [SC] ChangeServiceConfig SUCCESS.
5. In the Command Prompt, type the following command hscserver /start /y and click ENTER.
6. Ensure that you see the following message once the Experion PKS Server System service is started
successfully Starting Server.hsc_Server_Control_s stateRequired=4 ...................hsc_Server_Control_s - Exiting, at end with returnval 4
Completed successfully.

To validate the point release installation

To verify if the Experion PKS R430.3 is installed, perform the following steps:
Using Notepad, open the ProductVersion.txt file located in the following path.
C:\Program Files(X86)\Honeywell\Experion PKS OR <User selected path>\Honeywell\Experion PKS.
b Verify the ProductVersion.txt for the following:
+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PM

If the above line is present, it indicates that the installation is successful.


Note
After Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that the
system is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, you
may also see previous Experion release references in the product info.

32

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

Post-installation tasks
1

Log on as a member of Windows Administrators and Product Administrators group.

Perform the following steps to enable ERDB replication.


Attention
This step must be performed from Server B.

Open Configuration Studio.


b Select Administer Control Strategy Database. Perform the required steps to enable ERDB replication.
a

Perform the following steps to enable EMDB replication.


Attention
This step must be performed from Server B.

Open Configuration Studio.


b Select Administer the System Database. Perform the required steps to enable EMDB replication.
a

Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.

If the servers are not synchronized, click Synchronize. The servers are synchronized.

Click Manual Failover. The server failover takes place.


Attention
Server A becomes primary.

If the servers are not synchronized, click Synchronize. The servers are synchronized.

Turn on file replication of the mapping files .


In Station, click Configure > File Replication. Do not change Send check box in this display.
Click mapping entry.
The configuration page for mapping file replication entry appears.
c Select Replicate files from this path check box.
d Click Save.
a

Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must be
enabled.

10 Enable all the Checkpoint tasks.

To update Common Components packages (optional step)


1

Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.
Attention
Note that these steps must be performed ONLY if you install an optional common component package after
installing Experion PKS R430.3. The steps must be performed to update the installed optional common component
package version to Experion PKS R430.3 version.

Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installer
Experion PKS R430.3.

Browse to the respective sub folder containing the common component packages folder.

Choose Start > All Programs > Accessories > Command Prompt.

Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.

In the Command Prompt, enter the path of the common components update with the update name and click
ENTER.

33

2 EXPERION PKS R430.3 INSTALLATION

The common component update is installed. Updates to following common components are available.

AppTPSBase
Cl Server
AppTPSClient
AppTPSSolution
Experion Remote Native Window
Honeywell FTE MUX Driver
Experion GUS Display Builder
Experion GUS Display Runtime
Experion GUS Remote displays
Honeywell HCI Runtime
Honeywell IKB Service
Honeywell Redirection Manager
Honeywell SafeView
Honeywell Signon Manager
Honeywell System Management Runtime
Honeywell TPS Domain Console Configuration
Honeywell File Transfer - Client
Honeywell File Transfer - Server
Attention
SUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It is
mandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fix
KB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install the
Microsoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://
support2.microsoft.com/kb/2925489.

34

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

2.3 Installing the point release on Experion Application Server/ Console/


Flex/Console Extension station/eServer/Premium Access clients
Attention
Installing Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.
Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool from
Start > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKS
Start-Stop Services Control Panel tool to stop all services manually.

To stop the services


1

Log on to the server using an account that is part of both the Windows Administrators and Product
Administrators group.
Attention
Ensure that you log on with the mentioned required privileges.

For systems with licensed QVCS only: Open the QVCS Manager application and complete the required
QVCS operations (for example: Check in, Check out, revert, and so on). Close the QVCS Manager
application manually.

Perform the following Checkpoint tasks.


a

Disable all Checkpoint tasks; click Stop for all the scheduled Checkpoint tasks.
Attention
Any currently executing Checkpoint tasks must be complete before continuing. Ensure that all the automatic
or manual Checkpoint Save tasks are complete.

b
c

Ensure that the Checkpoint share has replicated correctly to all the Console stations.
To verify the replication of the Checkpoint shares, check the Event Summary Display page on the
Station after the manual/auto Checkpoint Saves are completed for all controllers. If the Event
Summary Display page does not display any replication failure event, the replication is successful.

Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.
Attention
You must enable the services after completing the procedure.

Close all the running applications.

If RSLinx is installed, perform the following steps to stop RSLinx for systems using ControlNet.
On the desktop, right-click My Computer and select Manage.
The Computer Management window appears.
b Expand Services and Applications in the left pane.
c Click Services.
The list of services appears in the right pane.
d Perform the following steps.
a

1. Right-click RSLinx Classic and select Stop.


2. Right-click Harmony and select Stop.
Close the Computer Management window.

To install the point Release

To install, perform the following steps.

35

2 EXPERION PKS R430.3 INSTALLATION

If you are using Experion Support and Maintenance (ESM) to install the point release, install the point
release from the ESM client. For more information, refer to the Installation Builder User's guide. If you
are not using ESM to install the point release, go to step b.
b Ensure that you are logged on using an account that is part of both the Windows Administrators and
Product Administrators group.
c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKS
R430.3 > supportsoftware.exe. If the installation is from the network then map the location where the
installer folder is located to the network drive.
a

Attention
1. In the command prompt, as an Administrator, type the following command.
net use <drive>: \\computername\share\<folder> (for example, net use Z: \\199.63.5.151\temp\Experion
PKS R430.3 )
Ensure that the path mapped (for example, \\199.63.5.151\temp\<point release>) has both Read and
Write permissions.
2. Type the user name and password (must be in quotes if there is a blank).
3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.
d

Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Control
dialog box is displayed, click Yes to continue.
The Welcome to Experion PKS Update Manager dialog box appears.
Click Install to start the Experion PKS R430.3 installation.
Attention

During the installation, when the system restarts, manually log on to the system with the required
credentials to continue with the installation.
If the installation is being performed from the network, after each system restart, map the drive to continue
the installation. To map the drive, perform the steps as given in the Attention of Step b.
You may see the following error message related to service which cause the installation to abort. Stop the
service manually after acknowledging the message and restart the installation.
Failed to stop <service name>. Installation will be aborted now.

Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

To install the point release on Premium Access clients

Perform the following steps to install the point release on Premium Access clients.
Ensure that the eServer that is associated with the Premium Access client is already updated.
b Log on to the server using an account with membership in the Local Administrators group and the
Product Administrators group.
c From the Start > Control Panel > Add or Remove Programs, select and remove the following
programs.

HMIWeb Browser Runtime


Experion PKS Server Client Components
d Open eServer home page and click on the link - Click here to install Premium Access components.
e Click the appropriate link to install the Premium Access components.
f Click the appropriate link to install the server client components.
To validate the point release installation

To verify if the Experion PKS R430.3 is installed, perform the following steps:
a

36

Using Notepad, open the ProductVersion.txt file located in the following path.
C:\Program Files(X86)\Honeywell\Experion PKS OR <User selected path>\Honeywell\Experion PKS.

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

Verify the ProductVersion.txt for the following:


+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PM
If the above line is present, it indicates that the installation is successful.
Note
After Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that the
system is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, you
may also see previous Experion release references in the product info.

Post-installation tasks
1

Log on as a member of Windows Administrators and Product Administrators group.

Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.

Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery
service (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must be
enabled.

Enable all the Checkpoint tasks.

To update Common Components packages (optional step)


1

Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.
Attention
Note that these steps must be performed ONLY if you install an optional common component package after
installing Experion PKS R430.3. The steps must be performed to update the installed optional common component
package version to Experion PKS R430.3 version.

Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installer
Experion PKS R430.3.

Browse to the respective sub folder containing the common component packages folder.

Choose Start > All Programs > Accessories > Command Prompt.

Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.

In the Command Prompt, enter the path of the common components update with the update name and click
ENTER.

The common component update is installed. Updates to following common components are available.

AppTPSBase
Cl Server
AppTPSClient
AppTPSSolution
Experion Remote Native Window
Honeywell FTE MUX Driver
Experion GUS Display Builder
Experion GUS Display Runtime
Experion GUS Remote displays
Honeywell HCI Runtime
Honeywell IKB Service
Honeywell Redirection Manager
Honeywell SafeView
Honeywell Signon Manager
Honeywell System Management Runtime
Honeywell TPS Domain Console Configuration

37

2 EXPERION PKS R430.3 INSTALLATION

Honeywell File Transfer - Client


Honeywell File Transfer - Server
Attention
SUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It is
mandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fix
KB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install the
Microsoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://
support2.microsoft.com/kb/2925489.

38

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

2.4 Installing the point release on ACE or SCE


Attention
Installing Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.
Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool from
Start > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKS
Start-Stop Services Control Panel tool to stop all services manually.

To stop the services


1

Perform the following steps.


Attention
Perform step a through step d on Control Builder from Server B (redundant server) or Experion server (nonredundant).

From Control Builder Monitoring view, right-click the node FB and select Upload.
The Upload box is displayed.
b Clear Upload Server Configuration Information check box and click Continue.
The tuning constants are uploaded from the controller to the Monitoring view of ERDB.
c Right-click the node FB and select Update to Project.
The Update dialog box is displayed.
d Click Continue to ensure that the updated tuning constants on the Monitoring view are updated into the
Project view of the ERDB.
e Perform a manual Checkpoint Save of the controller.
f Ensure that the Checkpoint shares have replicated correctly between the server and all the Console
stations.
g To verify the replication of the Checkpoint shares, check the Event Summary Display page on the
Station once the manual Checkpoint Save is completed for this controller. If the Event Summary
Display page does not display any replication failure event, the replication is successful.
a

Modify the node FB CEESTATE to IDLE.

Change the node FB ACE / SIM command to SHUTDOWN. For more information, refer to the Control
Building Users Guide.

Shutdown the node FB from the Control Builder.

To install the point Release

To install, perform the following steps.


If you are using Experion Support and Maintenance (ESM) to install the point release, install the point
release from the ESM client. For more information, refer to the Installation Builder User's guide. If you
are not using ESM to install the point release, go to step b.
b Ensure that you are logged on using an account that is part of both the Windows Administrators and
Product Administrators group.
c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKS
R430.3 > supportsoftware.exe. If the installation is from the network then map the location where the
installer folder is located to the network drive.

39

2 EXPERION PKS R430.3 INSTALLATION

Attention
1. In the command prompt, as an Administrator, type the following command.
net use <drive>: \\computername\share\<folder> (for example, net use Z: \\199.63.5.151\temp\Experion
PKS R430.3 )
Ensure that the path mapped (for example, \\199.63.5.151\temp\<point release>) has both Read and
Write permissions.
2. Type the user name and password (must be in quotes if there is a blank).
3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.
d

Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Control
dialog box is displayed, click Yes to continue.
The Welcome to Experion PKS Update Manager dialog box appears.
Click Install to start the Experion PKS R430.3 installation.
Attention

During the installation, when the system restarts, manually log on to the system with the required
credentials to continue with the installation.
If the installation is being performed from the network, after each system restart, map the drive to continue
the installation. To map the drive, perform the steps as given in the Attention of Step b.
You may see the following error message related to service which cause the installation to abort. Stop the
service manually after acknowledging the message and restart the installation.
Failed to stop <service name>. Installation will be aborted now.

Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

To validate the point release installation

To verify if the Experion PKS R430.3 is installed, perform the following steps:
Using Notepad, open the ProductVersion.txt file located in the following path.
C:\Program Files(X86)\Honeywell\Experion PKS OR <User selected path>\Honeywell\Experion PKS.
b Verify the ProductVersion.txt for the following:
+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PM

If the above line is present, it indicates that the installation is successful.


Note
After Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that the
system is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, you
may also see previous Experion release references in the product info.

Post-installation tasks
1

Perform a Checkpoint Restore for the node and correct any errors that are observed during the Checkpoint
Restore.

From the Control Builder Monitoring view, perform a COLDSTART or WARMSTART of ACE-CEE and
SCE-CEE as follows:
Open the ACE-CEE Configuration form.
b Click WARMSTART/COLDSTART (as applicable) from the CEE Command. For more information
about COLDSTART and WARMSTART, refer to the Control Building Users Guide.

40

Perform a Checkpoint Save after the node is successfully started. The CMs/SCMs are made active (in case
of a COLDSTART only). This ensures that the necessary runtime information and the correct execution
states of the CMs/SCMs is available in the latest .cp file of ACE node.

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

To update Common Components packages (optional step)


1

Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.
Attention
Note that these steps must be performed ONLY if you install an optional common component package after
installing Experion PKS R430.3. The steps must be performed to update the installed optional common component
package version to Experion PKS R430.3 version.

Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installer
Experion PKS R430.3.

Browse to the respective sub folder containing the common component packages folder.

Choose Start > All Programs > Accessories > Command Prompt.

Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.

In the Command Prompt, enter the path of the common components update with the update name and click
ENTER.

The common component update is installed. Updates to following common components are available.

AppTPSBase
Cl Server
AppTPSClient
AppTPSSolution
Experion Remote Native Window
Honeywell FTE MUX Driver
Experion GUS Display Builder
Experion GUS Display Runtime
Experion GUS Remote displays
Honeywell HCI Runtime
Honeywell IKB Service
Honeywell Redirection Manager
Honeywell SafeView
Honeywell Signon Manager
Honeywell System Management Runtime
Honeywell TPS Domain Console Configuration
Honeywell File Transfer - Client
Honeywell File Transfer - Server
Attention
SUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It is
mandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fix
KB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install the
Microsoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://
support2.microsoft.com/kb/2925489.

41

2 EXPERION PKS R430.3 INSTALLATION

2.5 Migrating controllers


Related topics
Updating the firmware on page 42
Firmware revision on page 42

2.5.1 Updating the firmware


1. Perform the upgrade readiness checks using the Upgrade Tool (UT).
For more information about UT, refer to the Experion Migration Planning Guide and Upgrade Tool Users
Guide.
2. Migrate the controllers and modules using the Controller Migration wizard (CMW).
CMW can be used for both on-process and off-process migration in an automated way. NTools and CTools
can be used for manual firmware upgrade.
For more information about CMW, refer to Controller Migration in the respective Scenario-specific
migration guide.

2.5.2 Firmware revision


The following table provides details about the firmware versions.
Module

Module number

Firmware version

File

C200E

TC-PRS022

EXP430.1-92.120

cee50e.pcm
cpmboote.pcm

C300

Cx-PCNT01

EXP430.1-92.120

c300.lcf
c300app2.pcm
c300app2_20.pcm
c300boot2.pcm
c300boot2_20.pcm

EHPM

EC-THPM01

EXP430.1-92.120

ehpm.lcf
ehpmapp1.pcm
ehpmboot1.pcm

EHB

EC-EHB01

EXP430.1-92.120

ehb.lcf
ehbapp1.pcm
ehbboot1.pcm

FIM

TK-FFIF01

EXP430.1-92.120

fimboot.nvs
fimboot.pcm
fimrex.nvs
fimrex.pcm

FIM4

Cx-PFB401

EXP430.1-92.120

fim4.lcf
fim4app2.pcm
fim4boot2.pcm

42

www.honeywell.com

2 EXPERION PKS R430.3 INSTALLATION

Module

Module number

Firmware version

File

FIM8

Cx-PFB801

EXP430.1-92.120

fim8.lcf
fim8app2.pcm
fim8boot2.pcm

FTEB

TC-FTEB01

EXP430.1-92.120

ftebboot.nvs
ftebboot.pcm
ftebrex.nvs
ftebrex.pcm

PGM2

Cx-IP0101

EXP430.1-92.120

pgm2.lcf
pgm2app1.pcm
pgm2boot1.pcm

IOLIM

TC-IOLI01

EXP430.1-92.120

iolimapp.nvs
iolimapp.pcm
iolimboot.nvs
iolimboot.pcm

43

2 EXPERION PKS R430.3 INSTALLATION

44

www.honeywell.com

3 Experion PKS R430.3 removal

Attention
Uninstallation of Experion PKS R430.3 is not supported.
Contact Honeywell TAC to uninstall Experion PKS R430.3.

45

3 EXPERION PKS R430.3 REMOVAL

46

www.honeywell.com

4 Notices

Trademarks
Experion, PlantScape, SafeBrowse, TotalPlant, and TDC 3000 are registered trademarks of Honeywell
International, Inc.
OneWireless is a trademark of Honeywell International, Inc.
Other trademarks
Microsoft and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries.
Trademarks that appear in this document are used only to the benefit of the trademark owner, with no intention
of trademark infringement.
Third-party licenses
This product may contain or be derived from materials, including software, of third parties. The third party
materials may be subject to licenses, notices, restrictions and obligations imposed by the licensor. The licenses,
notices, restrictions and obligations, if any, may be found in the materials accompanying the product, in the
documents or files accompanying such third party materials, in a file named third_party_licenses on the media
containing the product, or at http://www.honeywell.com/ps/thirdpartylicenses.

47

4 NOTICES

4.1 Documentation feedback


You can find the most up-to-date documents on the Honeywell Process Solutions support website at:
http://www.honeywellprocess.com/support
If you have comments about Honeywell Process Solutions documentation, send your feedback to:
hpsdocs@honeywell.com
Use this email address to provide feedback, or to report errors and omissions in the documentation. For
immediate help with a technical problem, contact your local Honeywell Process Solutions Customer Contact
Center (CCC) or Honeywell Technical Assistance Center (TAC) listed in the Support and other contacts
section of this document.

48

www.honeywell.com

4 NOTICES

4.2 How to report a security vulnerability


For the purpose of submission, a security vulnerability is defined as a software defect or weakness that can be
exploited to reduce the operational or security capabilities of the software.
Honeywell investigates all reports of security vulnerabilities affecting Honeywell products and services.
To report a potential security vulnerability against any Honeywell product, please follow the instructions at:
https://honeywell.com/pages/vulnerabilityreporting.aspx
Submit the requested information to Honeywell using one of the following methods:

Send an email to security@honeywell.com.

or
Contact your local Honeywell Process Solutions Customer Contact Center (CCC) or Honeywell Technical
Assistance Center (TAC) listed in the Support and other contacts section of this document.

49

4 NOTICES

4.3 Support
For support, contact your local Honeywell Process Solutions Customer Contact Center (CCC). To find your
local CCC visit the website, https://www.honeywellprocess.com/en-US/contact-us/customer-support-contacts/
Pages/default.aspx.

50

www.honeywell.com

4 NOTICES

4.4 Training classes


Honeywell holds technical training classes on Experion PKS. These classes are taught by experts in the field of
process control systems. For more information about these classes, contact your Honeywell representative, or
see http://www.automationcollege.com.