Beruflich Dokumente
Kultur Dokumente
scope
Intended user
Overseas
N2000UMS V200R12C02
N2000BMS V200R11C02
Softx3000 V300R601C05
UMG8900 V100R007C01
UA5000 PVMV100R017C02
Product version
Document
version
Edited by
Application
products
N2000UMS/N2000BMS/
SoftX3000/UMG8900/UA5000
Product name
V1.0
N2000UMS/N2000BMS/SoftX3000/UMG8900/UA5000
Xie Changzheng
Date:
Reviewed by:
Date:
Reviewed by:
Date:
Approved by:
Date:
2009-03-02
Confidentiality Level:
Internal
Revision Records
Date
2009-03-02
Revised version
V1.0
Description
Formal version completed
Author
Xie Changzheng
Confidentiality Level:
Internal
Contents
Chapter 1 Document Description ................................................................................................... 1
1.1 Document Description .......................................................................................................... 1
1.2 Document Objective ............................................................................................................. 1
Chapter 2 Preparing for Configuration........................................................................................... 2
2.1 Verify connection between N2000UMS & Softx3000 ........................................................... 2
2.2 Using N2000BMS Client to manage AG............................................................................... 2
2.3 Using MML Client of Softx3000 in N2000UMS..................................................................... 3
Chapter 3 Configuration Service .................................................................................................... 5
3.1 Configuration of call gapping (Based on CPU rate).............................................................. 5
3.2 Configuration of call gapping (Barring A number) ................................................................ 8
3.3 Configuration of call gapping (Destination Code) ............................................................... 10
3.4 Configuration of Office number segment............................................................................ 10
3.5 Configuration of called prefix and route .............................................................................. 11
3.6 Re-routing of Called prefix to new route ............................................................................. 13
3.7 Re-routing of route to new sub-routes ................................................................................ 14
3.8 Configuration of ISUP trunk & E1 ....................................................................................... 16
3.9 Configuration of Centrex group........................................................................................... 20
3.10 Configuration of subscriber authority ................................................................................ 22
3.11 Configuration of voice subscriber ..................................................................................... 24
3.12 Configuration of BRI subscriber........................................................................................ 25
3.13 Configuration of PBX - PRI ............................................................................................... 29
3.14 Configuration of Number change by Prefix Processing.................................................... 36
3.15 Configuration of Number change by Caller Number Analysis .......................................... 38
3.16 Configuration of Number change by Outgoing Trunk Group Bearer ................................ 39
3.
Testing ..................................................................................................................................... 41
1.
Confidentiality Level:
Internal
Keyword:
Multi-Product Configuration Guide
Summary:
NGN Multi-Product Configuration Guide for Customer Operation is applicable to
Customer Service Manager configuration engineer. This guide help the engineer to do
configuration based on the work ticket from fulfillment engineer through IT system.
Abbreviation list:
None
Reference list:
None
Confidentiality Level:
Internal
Confidentiality Level:
Internal
If color is grey: the network connection is broken and needs to check the network.
If color blue: the authentication is wrong and needs to confirm the password of softx3000
node in EMS.
Step 3, Confirm the color of softx3000 icon must be green, see figure above.
Confidentiality Level:
Internal
Confidentiality Level:
Internal
Step 3, After selecting the Start Client, the MML Client will appear as follow:
Explanation:
1. On left menu under MML navigation tree, management classes are well defined . Commands
related to respective managements can be found under the navigation tree. Double click the
command to select for input-field; If the command is definite, you can directly input the command to
the input-field and then press enter.
2. Top right window: output window to show the input command.
3. Help information pad: show the meaning of every parameter and give an example of command.
4. Right middle window: directly input command.
5. Right bottom frame: user-friendly command typing.
6. Alongside command input field, there are three tool icons (left to right), respectively
showing-input-frame (Enter), executing (F9), listing-table (only for list command).
Notice:
Every time before modifying the configuration, list the current configuration and take note.
Confidentiality Level:
Internal
N
Cancel barring
Barring 25%
Reached L1 resume?
Reached L2 threshold?
Barring 25%
Y
Barring 50%
Y
N
Reached L2 resume?
Reached L3 threshold?
Y
Barring 75%
Barring 50%
Y
N
Reached L3 resume?
Reached L4 threshold?
Y
Barring 100%
Barring 75%
Y
N
Reached L4 resume?
Confidentiality Level:
Internal
Step 3, Input the command and then press enter to display the friendly input interface. see the
following command and figure.
SET CPUTHD: MN=22, LV1=75, LV2=80, LV3=85, LV4=90, LR1=70, LR2=75, LR3=80,
LR4=85;
Confidentiality Level:
Internal
Step 4, After inputting all needed parameters and check it again, then press F9 or
click
the
executing tool icon, wait a few seconds, it will return the result, it should be no fault returned.
Step 5, List the configuration again to confirm the operation.
LST CPUTHD;
Step 6, Test at heavy traffic time.
Notice:
Normally, the default setting is ok, the module will control the traffic in real-time. On heavy traffic
situation like holiday, you can modify the cpu threshold value and only need to modify the threshold
of FCCU module, other types of module does not need to modify.
For example on heavy traffic day:
SET CPUTHD: MN=22, LV1=60, LV2=70, LV3=80, LV4=90, LR1=55, LR2=65, LR3=75, LR4=85;
Confidentiality Level:
Internal
Softswitch1
SW
Voice Net
Work
switch
PSTN
Soft switch Tests the incoming
trunk and A number, reject
blacklist and permit whitelist
B-number
A-number
Confidentiality Level:
Internal
After inputting all needed parameters and check it again, then press F9 or click the executing
tool icon, wait a few seconds, it will return the result, it should be no fault returned. To list the
configuration again to confirm the operation.
LST TG: TG=1000;
Step 4, For both of schemes, Add the discrimination number to incoming trunk group. See the follow
command and figure.
ADD TGDSG: TG=1000, DSG=1000;
After inputting all needed parameters, check it again, then press F9 or click the executing tool
icon, waiting a few seconds, it will return the result, it should be no fault returned. To list the
configuration again to confirm the operation.
LST TGDSG: TG=1000;
Step 5, Add Caller Number Discrimination. For scheme one, modify the barring number of caller
attribute to 6002, For scheme two, directly reject the call. See the follow command and figure.
scheme one, modify the barring number of caller attribute to 6002
1. ADD CLRDSN: DSP=1000, CLI=K'33334445, DSTYPE=NORT, DAI=UDN, FUNC=ATT,
GRP=6002, CMN=NO;
Confidentiality Level:
Internal
Confidentiality Level:
Internal
Interior Caller
Caller-barring
Caller-authority
meanses relative
Analyze callee
Interior Callee
(hardware-AG/UMG/V5)
(terminal-Sub/BRI/DDI/ console)
Route
Dest Office
Sub-route1
Sub-route2
Trunks1
Trunks2
Trunk Circuits
(hardware-UMG)
(signal-TUP/ISUP/PRI)
Confidentiality Level:
Internal
Step 3, Set Sub-route Attribute (Set the attribute of all sub-routes), See the following command
and figure.
SET SRTATTR: R=10, SR=10, PSR=50;
Notice:
The total percentages of all sub-routes must be times of 100.
Step 4, Add Route Analysis , See the following command and figure.
ADD RTANA: RSC=10, RSSC=0, RUT=ALL, SAI=ALL, CLR=ALL, TP=ALL, TMX=0, R=10,
ISUP=NOCHG, NCAI=ALL, CST=ALL, CNPI=ALL;
Step 5, Add Called Number Analysis, See the following command and figure.
ADD CNACLD: PFX=K'0355, CSTP=BASE, CSA=LC, RSC=10, MINL=10, MAXL=10, CHSC=0,
SDESCRIPTION="other_PSTN", EA=NO;
Huawei Proprietary, All Rights Reserved.
Confidentiality Level:
Internal
Interior Caller
Caller-barring
Caller-authority
meanses relative
Analyze callee
Interior Callee
(hardware-AG/UMG/V5)
(terminal-Sub/BRI/DDI/ console)
Route
Dest Office
Sub-route1
Sub-route2
Trunks1
Trunks2
Trunk Circuits
(hardware-UMG)
(signal-TUP/ISUP/PRI)
Confidentiality Level:
Internal
Step 1, First, check which route selection code is used for the new route, Use List Route
Analysis, See the follow command and figure.
LST RTANA: R=10;
Step 2, Modify Called Number Analysis, See the following command and figure.
MOD CNACLD: LP=0, PFX=K'3355, RSC=10, EA=NO;
In-trunk
Interior Caller
Caller-barring
Caller-authority
Confidentiality Level:
Internal
meanses relative
Analyze callee
Interior Callee
(hardware-AG/UMG/V5)
(terminal-Sub/BRI/DDI/ console)
Route
Dest Office
Sub-route1
Sub-route2
Trunks1
Trunks2
Trunk Circuits
(hardware-UMG)
(signal-TUP/ISUP/PRI)
Step 3, Set Sub-route Attribute (Set the attribute of all sub-routes), See the follow command and
figure.
SET SRTATTR: R=10, SR=10, PSR=50;
SET SRTATTR: R=10, SR=11, PSR=50;
Confidentiality Level:
Internal
Notice:
The total percentages of all sub-routes must be times of 100.
Step 4, To list the configuration to confirm the operation.
LST RT: R=10, SSR=YES, SRA=YES;
LST SRTATTR: R=10;
Step 5, Test the call by dialing callee number according on the route such as 3355XXXX.
Interior Caller
Caller-barring
Caller-authority
Confidentiality Level:
Internal
meanses relative
Analyze callee
Interior Callee
(hardware-AG/UMG/V5)
(terminal-Sub/BRI/DDI/
console)
Route
Dest Office
Sub-route1
Sub-route2
Trunks1
Trunks2
Trunk Circuits
(hardware-UMG)
(signalTUP/ISUP/PRI)
Step 3, Add M3UA Route, See the follow command and figure.
ADD M3RT: RTNAME="PSTN_SW_1", DEX=10, LSX=99;
ADD M3RT: RTNAME="PSTN_SW_2", DEX=10, LSX=100;
Confidentiality Level:
Internal
Explanation:
Step 4, Add Office Direction , See the follow command and figure.
ADD OFC: O=10, ON="PSTN_SW", DOT=CMPX, DOL=LOW, DPC1="1DFF01";
Step 6, Add No7 Trunk Group, See the follow command and figure.
ADD N7TG: TG=10, EID="10.10.10.10:5000", G=INOUT, SRC=10, TGN="PSTN_SW",
PRTFLG=ITUT, NOAA=FALSE, ISM=FALSE, EA=FALSE;
Huawei Proprietary, All Rights Reserved.
Confidentiality Level:
Internal
Step 7, Before configure the circuit, It should check the TID and E1 Port configuration of
UMG8900, such as follow.
LST BRD: LM=BTBN, BT=E32;
LST TDMIU: BT=E32, BN=0, PORTNO=5;
Confidentiality Level:
Internal
Step 8, Add No7 Trunk Circuit, See the follow command and figure (parameter of Start circuit
termination ID must check with the UMG8900 configuration).
ADD N7TKC: MN=22, TG=10, SC=0, EC=95, SCIC=0, TID="1024";
Confidentiality Level:
Internal
Step 3, Add Centrex Intra-Group Prefix, See the follow command and figure.
ADD ICXPFX: CXG=10, CLRLP=0, PFX=K'8, CSA=CIG, MINL=4, MAXL=4;
Step 4, Add Centrex Out-Group Prefix, See the follow command and figure.
ADD OCXPFX: CXG=10, OGP=K'9;
Confidentiality Level:
Internal
Step 3, Modify Supplementary Service, See the following command and figure.
MOD SS: D=K'33334455, LP=0, NS=CLIP-1;
Step 4, Park Owing Subscriber, See the following command and figure.
PRK OWSBR: D=K'33334455, LP=0;
Confidentiality Level:
Internal
Step 5, Restore Owing Subscriber, See the following command and figure.
RES OWSBR: D=K'33334455, LP=0;
Step 7, Restore Parking Subscriber, See the following command and figure.
RES SBR: D=K'33334455, LP=0;
Confidentiality Level:
Internal
Step 1, Check the TID of the line port, See the follow command.
Enter esl-interface
huawei(config)#esl use
huawei(config-esl-user)#
32
33334455 Cat3
Confidentiality Level:
Internal
----------------------------------------------------------------------------
Step 2, Add Voice Subscriber (no centrex), See the follow command and figure.
ADD VSBR: D=K'33334455, LP=0, DID=ESL, MN=22, EID="10.1.1.1:2944", TID="32",
RCHS=0, CSC=0, UTP=NRM, CNTRX=NO, PBX=NO, CHG=NO, ENH=NO;
Step 3, Add Voice Subscriber (centrex), See the follow command and figure.
ADD VSBR: D=K'33334455, LP=0, DID=ESL, MN=22, EID="10.1.1.1:2944", TID="32",
RCHS=0, CSC=0, UTP=NRM, CNTRX=YES, CGF=YES, CXG=10, CXD=K'8055, PBX=NO,
CHG=NO, ENH=NO;
Confidentiality Level:
Internal
Step 3, Add IUA Linkset with the SG (if in existence, need not create), See the follow command
and figure.
ADD IUALKS: LSX=1, LSNAME="NO1_AG", DT=BRA, MN=22, SGID=1;
Confidentiality Level:
Internal
Step 4, ADD IUA Link to the linkset (if in existence, need not create), See the follow command
and figure.
ADD IUALNK: MN=136, LNKN=0, LSX=1, LOCPORT=9900, LOCIP1="10.10.10.100",
PEERPORT=9900, PEERIP1="10.1.1.1";
Step 5, Add a Media-Gateway-interface signaling (H248). (If in existence, need not create) The data
on the switch side (matching that to AG side) has to be configured correctly.
Add an MG interface.
huawei(config)#interface h248 0
Are you sure you want to add MG interface?(y/n)[n]:y
huawei(config-if-h248-0)#
Step 6, Add an IUA link set and an IUA link (if existence, no need to create), See the follow
command (the IP address and port must be according to the configuration of softx3000).
huawei(config)#sigtran
huawei(config-sigtran)#iua-linkset add 1 pendingtime 4
huawei(config-sigtran)#iua-link add 15 1 9900 10.1.1.1 9900 10.10.10.100
huawei(config-sigtran)#display iua-link attribute
Confidentiality Level:
Internal
---------------------------------------------------------------------LinkNo : 15
LinksetNo : 1
Local prot : 9900
Local IP address : 10.1.1.1
Remote port : 9900
Remote IP address 1 : 10.10.10.100
---------------------------------------------------------------------huawei(config-sigtran)#display iua-link state
Step 7, Check the UserIFID and TID of the port, it will be used for configuration of softx3000.
huawei(config)#esl user
huawei(config-esl-user)#display port state 0/15
-----------------------------------------------------------------------------F/ S/ P Type SubType PortState SvcState SvcType UserType MgID ProtocolID
-----------------------------------------------------------------------------0/15/0 BRA 2B+D
MG
A64
No
Cat3 A64
----------------------------------------------------------------------------huawei(config-esl-user)#quit
huawei(config)#save
Step 8, Add ISDN Data for ISDN subscriber (if in existence, need not create), See the follow
command and figure.
ADD ISDNDAT: ISDN=1, BCHN=2, CMT=5;
Confidentiality Level:
Internal
Step 9, Add BRA Subscriber, See the follow command and figure.
ADD BRA: LP=0, D=K'33334456, DID=BRA, EID="10.1.1.1:2944", TID="64", LKS=1, IID=0,
ISDN=1, CSC=0, RCHS=0, CUGU=NO;
Confidentiality Level:
Internal
Step 3, Add IUA Linkset to the SG for PRALink (if existence, neednt to create), See the follow
command and figure.
ADD IUALKS: LSX=10, LSNAME="NO1_AG_PRA", DT=PRA, SGID=1;
Confidentiality Level:
Internal
Step 4, Add IUA Link to the linkset (if existence, no need to create), See the follow command and
figure.
ADD IUALNK: MN=136, LNKN=10, LSX=10, LOCPORT=9910,
PEERPORT=9910, PEERIP1="10.1.1.1";
LOCIP1="10.10.10.100",
Step 5, Add L2UA Link Set and LINK (if existence, need not create), See following
and figure.
command
Confidentiality Level:
Internal
Step 6, Add Q921 Signaling Link, to connect the IFID and the time-slot.
ADD Q921LNK: LNKNO=0, LNKNAME="PBX-PRA0", LKS=1, BINIFID=0,
IFBN=0, E1T1N=0, TS=16, SPFBN=0, SUBBN=0, NETUSER=NET;
IFBT=E32,
Confidentiality Level:
Internal
Step 7, Add PRA Link for PRATrunk, See the follow command and figure.
ADD PRALNK: PLN=0, SCN=16, MN=22, LKS=10, BINIFID=0, MSWM=NO;
Step 8, Add ISDN Data for PRA Subscriber (if existence, no need to create), See the follow
command and figure.
ADD ISDNDAT: ISDN=10, BCHN=30, CMT=20;
Step 9, Add PRA Subscriber to control authority of PRI trunk group, See the follow command and
figure.
ADD PRA: LP=0, D=K'33339999, ISDN=10, LOCM=RSC, RSC=9999, MN=22,
RCHS=0, CUGU=NO;
CSC=0,
Confidentiality Level:
Internal
Step 10, Add Office Direction for all PRA (if existence, need not create), See following command
and figure.
ADD OFC: O=9999, ON="PRA", DOT=PBX, DOL=LOW;
Step 11, Add Sub-Route to office for PRA trunk, See following
Step 12, Add PRA Trunk Group, See following command and
figure.
Confidentiality Level:
Internal
Step 13, Add PRA Trunk Circuit to PRA Trunk, See following
Step 14, Add Route for callee number, See following command and figure.
ADD RT: R=9999, RN="PRA_NO1", IDTP=UNKNOWN, SR1=9999;
Step 15, Add Route Analysis for callee number, See following command and figure.
ADD RTANA: RSC=9999, RSSC=0, RUT=ALL, SAI=ALL, CLR=ALL, TP=ALL,
TMX=0, R=9999, ISUP=NOCHG, NCAI=ALL, CST=ALL, CNPI=ALL;
Confidentiality Level:
Internal
Step 16, Add Called Number Analysis, See following command and figure.
ADD CNACLD: PFX=K'333399, CSTP=BASE, RSC=9999, MINL=8, MAXL=8, CHSC=0,
SDESCRIPTION="PRA_NO1", EA=NO;
Confidentiality Level:
Internal
This example is modifying the first two digit to 04. It can be modifying, deleting, adding, replacing.
Step 3, Add Call Prefix Processing (based on callee condition), See following command and
figure.
ADD PFXPRO: CSC=65534, PFX=K'03, CPPN="change caller and called", CCF=YES,
SENDTONE=NST, PROCSTART=YES, DDCX=1, RDCX=2, ISREANA=NO;
This example is change caller number by index 2, change called number by index 1, and no
needing reanalysis. The change will affect the CDR
Step 4, Modify Called Number Analysis to permit the prefix analysis, See the follow command
and figure.
MOD CNACLD: LP=0, PFX=K'03, EA=YES, SPCDAF=YES;
Confidentiality Level:
Internal
Explanation:
This example is modifying the first two digit to 04. It can be modifying, deleting, adding, replacing.
Confidentiality Level:
Internal
Explanation:
This example is change caller number by index 1, change called number by index 2, and no
needing reanalysis. The change will affect the CDR.
Step 4, Modify Called Number Analysis to permit the caller analysis, See following command
and figure.
MOD CNACLD: LP=0, PFX=K'03, EA=YES, CLRAF=YES;
Confidentiality Level:
Internal
Explanation:
This example is modifying the first two digit to 04. It can be modifying, deleting, adding, replacing.
Step 3, Add Trunk Group Bearer, See the follow command and
figure.
Explanation:
This example is change caller number by index 1, change called number by index 2. The
change will not affect the CDR.
Step 4, Add Trunk Group Bearer Index, See the follow command and figure.
ADD TGLDIDX: TG=35, CSC=65534, LP=0, PFX=K'03, CLI=1;
Confidentiality Level:
Internal
3. Testing
Step 2, Set office information and Logon the LMT, See the
following figure.
Step 3, After logon the LMT, Click the maintenance navigator tree,
Select
Service->Trace
management->User Trace Task->Interface Signaling and double click, See the
following
figure.
Confidentiality Level:
Internal
Step 4, After double click, A interface is displayed. Input the caller number and the DN Set (if it is
incoming from trunk,
the DN Set should be 65534), then click the OK button to
trace
the
signaling.
Step 5, After creating the trace task, It will test by dialing the certain callee by the caller being traced.
Step 6, See into the detailed signaling trace by double clicking each signal, to verify whether the
configuration is correct or not.