Sie sind auf Seite 1von 6

RETAINING WALL DESIGN

KeyWall_2012 Version 3.7.2 Build 10


Project: San Juan Muro Policia
Project No: 1
Case: Case 1
Design Method: Rankine-w/Batter (modified soil interface)
Design Parameters
Soil Parameters:
Reinforced Fill
Retained Zone
Foundation Soil
Reinforced Fill Type:
Unit Fill:
Minimum Design Factors of Safety
sliding:
1.50
overturning:
2.00
bearing:
3.00

Date: 01/14/2015
Designer:

f deg
c kN/m2
27
0.00
27
0.00
27
0.00
Sand, Silt or Clay
Crushed Stone, 25mm minus

pullout:
shear:
bending:

1.50
1.50
1.50

g kN/m3
14.70
14.70
14.70

uncertainties:
connection:

1.50
1.50

Design Preferences

Reinforcing Parameters: Tensar-UXMSE Geogrids


Tult
RFcr
RFd
RFid
UX1400MSE
70.05
2.60
1.00
1.05
Analysis:

Case: Case 1
Keystone 1
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge:

LTDS
25.66

FS
1.50

Tal
17.11

CompacIII / 18.85 kN/m3


Crushed Stone
3.30 m
Offset: 0.00 m
LL: 2.39 kN/m2 uniform surcharge
Load Width: 30.48 m

Results:

Sliding
Overturning
Bearing
Factors of Safety:
1.94
4.01
4.20
Calculated Bearing Pressure: 70.21 / 68.86 kN/m2
Eccentricity at base: 0.32 m
Reinforcing: (m & kN/m)
Calc.
Allow Ten
Layer Height
Length Tension
Reinf. Type
Tal
5
2.84
2.80
2.28
UX1400MSE
17.11 ok
4
2.24
2.50
4.13
UX1400MSE
17.11 ok
3
1.63
2.50
6.18
UX1400MSE
17.11 ok
2
1.02
2.50
8.23
UX1400MSE
17.11 ok
1
0.41
2.50
12.20
UX1400MSE
17.11 ok
Reinforcing Quantities (no waste included):
UX1400MSE 12.80 m2/m

Ci
0.70

Cds
0.70

Wall Batter: 0.00 deg (Hinge Ht N/A)


embedment: 0.50 m
DL: 0.00 kN/m2 uniform surcharge
Load Width: 30.48 m
Shear
4.98

Bending
2.22

Pk Conn
Tcl
6.47 ok
9.57 ok
12.67 ok
14.08 ok
15.14 ok

Pullout
FS
1.58 ok
2.23 ok
3.41 ok
4.57 ok
4.84 ok

NOTE: THESE CALCULATIONS ARE FOR PRELIMINARY DESIGN ONLY AND SHOULD
NOT BE USED FOR CONSTRUCTION WITHOUT REVIEW BY A QUALIFIED ENGINEER

Date 01/15/2015

Case 1

Page 1

RETAINING WALL DESIGN


KeyWall_2012 Version 3.7.2 Build 10
Project: San Juan Muro Policia
Project No: 1
Case: Case 2
Design Method: Rankine-w/Batter (modified soil interface)
Design Parameters
Soil Parameters:
Reinforced Fill
Retained Zone
Foundation Soil
Reinforced Fill Type:
Unit Fill:

Date: 01/14/2015
Designer:

f deg
c kN/m2
27
0.00
27
0.00
27
0.00
Sand, Silt or Clay
Crushed Stone, 25mm minus

g kN/m3
14.70
14.70
14.70

Seismic Design A=0.21 g, Kh(Ext)=0.130 , Kh(Int)=0.260 , Kv=0.000


Minimum Design Factors of Safety (seismic are 75% of static)
sliding:
1.20/0.90
pullout:
1.50/1.13
overturning:
1.00/0.75
shear:
1.50/1.13
bearing:
2.00/1.50
bending:
1.50/1.13

uncertainties:
connection:

1.50/1.13
1.50/1.13

Design Preferences

Reinforcing Parameters: Tensar-UXMSE Geogrids


Tult
RFcr
RFd
RFid
UX1400MSE
70.05
2.60
1.00
1.05
Analysis:

Case: Case 2
Keystone 1
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge:

LTDS
25.66

FS
Tal
Ci
1.50 17.11/59.30 0.70

CompacIII / 18.85 kN/m3


Crushed Stone
3.30 m
Offset: 0.00 m
LL: 2.39 kN/m2 uniform surcharge
Load Width: 30.48 m

Results:

Cds
0.70

Wall Batter: 0.00 deg (Hinge Ht N/A)


embedment: 0.50 m
DL: 0.00 kN/m2 uniform surcharge
Load Width: 30.48 m

Sliding
Overturning
Bearing
Factors of Safety:
2.31/1.71
5.77/3.75
5.63/4.66
Calculated Bearing Pressure: 63.62 / 61.92 / 69.77 kN/m2
Eccentricity at base: 0.27 m/0.43 m
Reinforcing: (m & kN/m)
Calc.
Allow Ten
Layer Height
Length Tension
Reinf. Type
Tal
5
2.84
3.30 2.28 / 4.12
UX1400MSE
17.11/59.30 ok
4
2.24
3.00 4.13 / 6.25
UX1400MSE
17.11/59.30 ok
3
1.63
3.00 6.18 / 9.06
UX1400MSE
17.11/59.30 ok
2
1.02
3.00 8.23 / 11.86
UX1400MSE
17.11/59.30 ok
1
0.41
3.00 12.20 / 16.49
UX1400MSE
17.11/59.30 ok
Reinforcing Quantities (no waste included):
UX1400MSE 15.30 m2/m

Shear
4.98/3.63

Pk Conn
Tcl
6.47/8.62 ok
9.57/12.76 ok
12.67/16.89 ok
14.08/18.77 ok
15.14/20.19 ok

Bending
2.22/1.97

Pullout
FS
2.63/1.16 ok
3.58/1.89 ok
4.83/2.64 ok
6.03/3.35 ok
6.08/3.60 ok

NOTE: THESE CALCULATIONS ARE FOR PRELIMINARY DESIGN ONLY AND SHOULD
NOT BE USED FOR CONSTRUCTION WITHOUT REVIEW BY A QUALIFIED ENGINEER

Date 01/15/2015

Case 2

Page 2

RETAINING WALL DESIGN


KeyWall_2012 Version 3.7.2 Build 10
Project: San Juan Muro Policia
Project No: 1
Case: Case 3
Design Method: Rankine-w/Batter (modified soil interface)
Design Parameters
Soil Parameters:
Reinforced Fill
Retained Zone
Foundation Soil
Reinforced Fill Type:
Unit Fill:
Minimum Design Factors of Safety
sliding:
1.50
overturning:
2.00
bearing:
3.00

Date: 01/14/2015
Designer:

f deg
c kN/m2
27
0.00
27
0.00
27
0.00
Sand, Silt or Clay
Crushed Stone, 25mm minus

pullout:
shear:
bending:

1.50
1.50
1.50

g kN/m3
14.70
14.70
14.70

uncertainties:
connection:

1.50
1.50

Design Preferences

Reinforcing Parameters: Tensar-UXMSE Geogrids


Tult
RFcr
RFd
RFid
UX1400MSE
70.05
2.60
1.00
1.05
Analysis:

Case: Case 3
Keystone 1
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge:

LTDS
25.66

FS
1.50

Tal
17.11

CompacIII / 18.85 kN/m3


Crushed Stone
2.90 m
Offset: 0.00 m
LL: 2.39 kN/m2 uniform surcharge
Load Width: 30.48 m

Results:

Sliding
Overturning
Bearing
Factors of Safety:
2.18
5.10
5.32
Calculated Bearing Pressure: 58.03 / 56.49 kN/m2
Eccentricity at base: 0.25 m
Reinforcing: (m & kN/m)
Calc.
Allow Ten
Layer Height
Length Tension
Reinf. Type
Tal
5
2.64
2.70
1.38
UX1400MSE
17.11 ok
4
2.03
2.50
3.47
UX1400MSE
17.11 ok
3
1.42
2.50
5.52
UX1400MSE
17.11 ok
2
0.81
2.50
7.57
UX1400MSE
17.11 ok
1
0.20
2.50
7.88
UX1400MSE
17.11 ok
Reinforcing Quantities (no waste included):
UX1400MSE 12.70 m2/m

Ci
0.70

Cds
0.70

Wall Batter: 0.00 deg (Hinge Ht N/A)


embedment: 0.50 m
DL: 0.00 kN/m2 uniform surcharge
Load Width: 30.48 m
Shear
5.18

Bending
4.36

Pk Conn
Tcl
5.47 ok
8.57 ok
11.67 ok
13.73 ok
14.80 ok

Pullout
FS
1.52 ok
2.49 ok
3.72 ok
4.91 ok
7.43 ok

NOTE: THESE CALCULATIONS ARE FOR PRELIMINARY DESIGN ONLY AND SHOULD
NOT BE USED FOR CONSTRUCTION WITHOUT REVIEW BY A QUALIFIED ENGINEER

Date 01/15/2015

Case 3

Page 3

RETAINING WALL DESIGN


KeyWall_2012 Version 3.7.2 Build 10
Project: San Juan Muro Policia
Project No: 1
Case: Case 4
Design Method: Rankine-w/Batter (modified soil interface)
Design Parameters
Soil Parameters:
Reinforced Fill
Retained Zone
Foundation Soil
Reinforced Fill Type:
Unit Fill:

Date: 01/14/2015
Designer:

f deg
c kN/m2
27
0.00
27
0.00
27
0.00
Sand, Silt or Clay
Crushed Stone, 25mm minus

g kN/m3
14.70
14.70
14.70

Seismic Design A=0.21 g, Kh(Ext)=0.130 , Kh(Int)=0.260 , Kv=0.000


Minimum Design Factors of Safety (seismic are 75% of static)
sliding:
1.20/0.90
pullout:
1.50/1.13
overturning:
1.00/0.75
shear:
1.50/1.13
bearing:
2.00/1.50
bending:
1.50/1.13

uncertainties:
connection:

1.50/1.13
1.50/1.13

Design Preferences

Reinforcing Parameters: Tensar-UXMSE Geogrids


Tult
RFcr
RFd
RFid
UX1400MSE
70.05
2.60
1.00
1.05
Analysis:

Case: Case 4
Keystone 1
Unit Type:
Leveling Pad:
Wall Ht:
Level Backfill
Surcharge:

LTDS
25.66

FS
Tal
Ci
1.50 17.11/59.30 0.70

CompacIII / 18.85 kN/m3


Crushed Stone
2.90 m
Offset: 0.00 m
LL: 2.39 kN/m2 uniform surcharge
Load Width: 30.48 m

Results:

Cds
0.70

Wall Batter: 0.00 deg (Hinge Ht N/A)


embedment: 0.50 m
DL: 0.00 kN/m2 uniform surcharge
Load Width: 30.48 m

Sliding
Overturning
Bearing
Factors of Safety:
2.43/1.82
6.40/4.23
6.26/5.38
Calculated Bearing Pressure: 55.20 / 53.50 / 59.13 kN/m2
Eccentricity at base: 0.23 m/0.36 m
Reinforcing: (m & kN/m)
Calc.
Allow Ten
Layer Height
Length Tension
Reinf. Type
Tal
5
2.44
2.90 1.82 / 3.09
UX1400MSE
17.11/59.30 ok
4
2.03
2.80 3.03 / 4.70
UX1400MSE
17.11/59.30 ok
3
1.42
2.80 5.52 / 7.74
UX1400MSE
17.11/59.30 ok
2
0.81
2.80 7.57 / 10.42
UX1400MSE
17.11/59.30 ok
1
0.20
2.80 7.88 / 11.46
UX1400MSE
17.11/59.30 ok
Reinforcing Quantities (no waste included):
UX1400MSE 14.10 m2/m

Shear
5.18/3.59

Pk Conn
Tcl
6.50/8.67 ok
8.57/11.42 ok
11.67/15.55 ok
13.73/18.31 ok
14.80/19.73 ok

Bending
2.17/1.93

Pullout
FS
2.93/1.38 ok
3.75/1.93 ok
4.56/2.60 ok
5.77/3.35 ok
8.51/4.68 ok

NOTE: THESE CALCULATIONS ARE FOR PRELIMINARY DESIGN ONLY AND SHOULD
NOT BE USED FOR CONSTRUCTION WITHOUT REVIEW BY A QUALIFIED ENGINEER

Date 01/15/2015

Case 4

Page 4

RETAINING WALL DESIGN


KeyWall_2012 Version 3.7.2 Build 10
Project: San Juan Muro Policia
Project No: 1
Case: Case 5
Design Method: Rankine-w/Batter (modified soil interface)
Design Parameters
Soil Parameters:
Reinforced Fill
Retained Zone
Foundation Soil
Reinforced Fill Type:
Unit Fill:
Minimum Design Factors of Safety
sliding:
1.50
overturning:
2.00
bearing:
3.00

Date: 01/14/2015
Designer:

f deg
c kN/m2
27
0.00
27
0.00
27
0.00
Sand, Silt or Clay
Crushed Stone, 25mm minus

pullout:
shear:
bending:

1.50
1.50
1.50

g kN/m3
14.70
14.70
14.70

uncertainties:
connection:

1.50
1.50

Design Preferences

Reinforcing Parameters: Tensar-UXMSE Geogrids


Tult
RFcr
RFd
RFid
UX1400MSE
70.05
2.60
1.00
1.05
Analysis:

Case: Case 5
Keystone 1
Unit Type:
Leveling Pad:
Wall Ht:
BackSlope:
Surcharge:

LTDS
25.66

FS
1.50

Tal
17.11

CompacIII / 18.85 kN/m3


Crushed Stone
2.50 m
15.00 deg. slope,
LL: 2.39 kN/m2 uniform surcharge
Load Width: 30.48 m

Results:

Sliding
Overturning
Bearing
Factors of Safety:
1.72
3.69
4.64
Calculated Bearing Pressure: 56.95 / 56.95 kN/m2
Eccentricity at base: 0.21 m
Reinforcing: (m & kN/m)
Calc.
Allow Ten
Layer Height
Length Tension
Reinf. Type
Tal
4
2.03
2.00
1.81
UX1400MSE
17.11 ok
3
1.42
2.00
3.99
UX1400MSE
17.11 ok
2
0.81
2.00
6.25
UX1400MSE
17.11 ok
1
0.20
2.00
6.93
UX1400MSE
17.11 ok
Reinforcing Quantities (no waste included):
UX1400MSE 8.00 m2/m

Ci
0.70

Cds
0.70

Wall Batter: 0.00 deg (Hinge Ht N/A)


embedment: 0.50 m
10.00 m long
DL: 0.00 kN/m2 uniform surcharge
Load Width: 30.48 m
Shear
5.55

Bending
3.95

Pk Conn
Tcl
6.53 ok
9.63 ok
12.73 ok
14.10 ok

Pullout
FS
2.24 ok
3.08 ok
3.98 ok
6.04 ok

NOTE: THESE CALCULATIONS ARE FOR PRELIMINARY DESIGN ONLY AND SHOULD
NOT BE USED FOR CONSTRUCTION WITHOUT REVIEW BY A QUALIFIED ENGINEER

Date 01/15/2015

Case 5

Page 5

RETAINING WALL DESIGN


KeyWall_2012 Version 3.7.2 Build 10
Project: San Juan Muro Policia
Project No: 1
Case: Case 6
Design Method: Rankine-w/Batter (modified soil interface)
Design Parameters
Soil Parameters:
Reinforced Fill
Retained Zone
Foundation Soil
Reinforced Fill Type:
Unit Fill:

Date: 01/14/2015
Designer:

f deg
c kN/m2
27
0.00
27
0.00
27
0.00
Sand, Silt or Clay
Crushed Stone, 25mm minus

g kN/m3
14.70
14.70
14.70

Seismic Design A=0.21 g, Kh(Ext)=0.130 , Kh(Int)=0.260 , Kv=0.000


Minimum Design Factors of Safety (seismic are 75% of static)
sliding:
1.20/0.90
pullout:
1.50/1.13
overturning:
1.00/0.75
shear:
1.50/1.13
bearing:
2.00/1.50
bending:
1.50/1.13

uncertainties:
connection:

1.50/1.13
1.50/1.13

Design Preferences

Reinforcing Parameters: Tensar-UXMSE Geogrids


Tult
RFcr
RFd
RFid
UX1400MSE
70.05
2.60
1.00
1.05
Analysis:

Case: Case 6
Keystone 1
Unit Type:
Leveling Pad:
Wall Ht:
BackSlope:
Surcharge:

LTDS
25.66

FS
Tal
Ci
1.50 17.11/59.30 0.70

CompacIII / 18.85 kN/m3


Crushed Stone
2.50 m
15.00 deg. slope,
LL: 2.39 kN/m2 uniform surcharge
Load Width: 30.48 m

Results:

Cds
0.70

Wall Batter: 0.00 deg (Hinge Ht N/A)


embedment: 0.50 m
10.00 m long
DL: 0.00 kN/m2 uniform surcharge
Load Width: 30.48 m

Sliding
Overturning
Bearing
Factors of Safety:
1.72/1.18
3.69/2.19
4.64/2.87
Calculated Bearing Pressure: 56.95 / 56.95 / 77.30 kN/m2
Eccentricity at base: 0.21 m/0.41 m
Reinforcing: (m & kN/m)
Calc.
Allow Ten
Layer Height
Length Tension
Reinf. Type
Tal
4
2.03
2.10 1.81 / 3.48
UX1400MSE
17.11/59.30 ok
3
1.42
2.00 3.99 / 6.48
UX1400MSE
17.11/59.30 ok
2
0.81
2.00 6.25 / 9.86
UX1400MSE
17.11/59.30 ok
1
0.20
2.00 6.93 / 11.68
UX1400MSE
17.11/59.30 ok
Reinforcing Quantities (no waste included):
UX1400MSE 8.10 m2/m

Shear
5.55/3.32

Pk Conn
Tcl
6.53/8.71 ok
9.63/12.84 ok
12.73/16.97 ok
14.10/18.80 ok

Bending
3.95/1.47

Pullout
FS
2.78/1.16 ok
3.08/1.52 ok
3.98/2.02 ok
6.04/2.87 ok

NOTE: THESE CALCULATIONS ARE FOR PRELIMINARY DESIGN ONLY AND SHOULD
NOT BE USED FOR CONSTRUCTION WITHOUT REVIEW BY A QUALIFIED ENGINEER

Date 01/15/2015

Case 6

Page 6

Das könnte Ihnen auch gefallen