Standby Model:P220EB
110-480V 3P4W
QUALITY STANDARDS
The SUPERWATT generator set compliance with all main
standards, such as ISO8528 (GB/T2820-97), GB755,
BS5000, VDE0530, ISO3046, IEC34-1, CSA22-2, AS1359,
ISO14001.
Rating Range
Standby:
kW
kVA
1500RPM 50Hz
176
220
Prime:
kW
kVA
160
200
WARRANTY
ALTERNATOR RATINGS
Alternator Model
UCI274H(STAMFORD)
50Hz
SPG341H(SPARKS)
1500rpm
50Hz
1500rpm
Cont.H -125/40
Cont.H -125/40
380
400
415
440
380
400
415
440
190
200
208
220
190
200
208
220
220
230
240
254
220
230
240
254
Rating capacity(kVA)
200
200
200
N/A
200
200
200
N/A
Rating power(kW)
160
160
160
N/A
160
160
160
N/A
Power efficiency(%)
93.0
93.3
93.4
N/A
93.0
93.3
93.4
N/A
171.3
N/A
172.0 171.5
171.3
N/A
Input power(kW)
172.0 171.5
Standby.H -163/27
380
400
415
440
380
400
415
440
190
200
208
220
190
200
208
220
220
230
240
254
220
230
240
254
Rating capacity(kVA)
220
220
220
N/A
220
220
220
N/A
Rating power(kW)
176
176
176
N/A
176
176
176
N/A
Power efficiency(%)
92.7
93.0
93.2
N/A
92.7
93.0
93.2
N/A
188.8
N/A
188.8
N/A
Input power(kW)
189.9 189.2
RATINGS: All three-phase units are rated at 0.8 power factor. Standby ratings : Standby
ratings apply to installations served by a reliable utility source. The standby rating is for
this rating. Ratings are in according with ISO-3046/1,BS 5514 ,AS 2789 , and DIN 6271.
Prime Power Ratings: Prime power ratings apply to installations where utility power is
unavailable or unreliable. At varying load, the number of generator set operating hours
is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in
accordance with IS0-8528/1, overload capacity in accordance with ISO-3046/1,BS 5514,
AS 2789, and DIN 6271. For limited running time and base load ratings, consult the
factory. The generator set manufacturer reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever.
GENERAL GUIDELINES FOR DERATION: Altitude: Derate 2.0% per 300m(984 ft.)
elevation above 1000m(3279 ft.) up to a maximum elevation of 2450m(8000 ft.).More than
2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11
(20
) temperature above 40 (104
).
Standby.H -163/27
189.9 189.2
In line with our policy of continuous product development, we reserve the right to
change the specification without notice.
ALTERNATOR
Specification
1500RPM
Type
Exciter type
Voltage regulator(AS440)
Voltage regulation
Insulation
Protection
Rated power factor
50HZ
1.5%
Class H
IP23
0.8
Double layer concentric
Stator winding
Winding pitch
Two thirds
Winding leads
Maximum overspeed
12
2250 Rev/min
Self excited machines do not
sustain a short circuit current
No load < 1.5%
Non-distorting balanced
linear load < 5.0%
1000 m
Altitude
DIESEL ENGINE
Engine Electrical
Application Data
Engine Specifications
PERKINS
Manufacturer
Number of cylinders
6
Vertical in-line
Cylinder arrangement
Cycle
Induction system
Compression ratio
Bore
Stroke
Cubic capacity
Direction of rotation
1500RPM 50Hz
1500RPM 50Hz
Negative
12V
85A
12V
4KW
12V
Fuel
135mm
7.01 litres
Anti-clockwise viewed on flywheel
Fuel System
1500RPM 50Hz
Direct
DP210G
1500RPM 50Hz
Firing order
1, 5, 3, 6, 2, 4
191.3kW
788kg
0.5%
6.75m/s
180 litres/hr
17 kPa
Pressure
137.9 kPa
Exhaust
10kPa
Exhaust System
Governor type
Electronic governor
Fuel Consumption
1500RPM 50Hz
Standby power
46.3 litre/hr
Prime Power
45.0 litre/hr
34.7 litre/hr
24.0 litre/hr
1500RPM 50Hz
10.0 kPa
36.6 m 3/min
580
Lubrication
Lubrication System
Total lubrication capacity
1500RPM 50Hz
16.5 litres
Application Data
Cooling System
Coolant System
1500RPM 50Hz
Face area
0.60 m 2
68.9 kPa (9.90 lb/in2 )
103
(218 )
21 litres
375 m3 /min
79
5
35 kPa( 5.1 lbf/in2 )
82 - 95
NOTE:
All data is based on:
1. All data based on operation to BSAU141A 1971; BS5514; ISO3046/1 1982; DIN6271.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
Barometric Pressure : 101.3 kPa (29.53 in Hg)
Air Temperature : 25 (77 )
Altitude : 110 m (361 ft)
Relative Humidity : 30%
Air Intake Restriction : 254 mm H2O (10 in H2O)
Exhaust Restriction : 51 mm Hg (2 in Hg)
Protection:
Over Speed Shutdown.
Low Oil Pressure Shutdown.
High Engine Temp Shutdown.
Charger failure alarm.
Mains failure alarm.
Optional Under speed Protection.
TBA: To Be Determined
CONTROLLERS
Panel introduction:
Indicator or digital type frequency, voltmeter and ampere meter
to display unit's electrical parameter.
The big red button uses for the operator to stop the genset
emergently.
The controller.
Function:
Communication: RS232 connection, uses the industry rank
MODBUS protocol can easily communicate with others
intelligence control system.
Display function: LCD screen can display the generator's
parameter and the control system's running information.
Set up parameter: Engineer can set up the controller parameter
from the control panel or through the PC, 6 programmable
fan-out may satisfy the user each kind of demand.
Protection: The control system can protect the generator set ,
manage each kind of electrical failure.
Control Function of ATS.
DC Supply: 8 to 35 V Continuous.
Paralleling System
Controller System
Accessories
Enclosed Unit
Miscellaneous Accessories
Sound Enclosure
Weather Enclosure (with enclosed critical silencer)
Weather Housing (with roof-mounted critical silencer)
Trailer(Causes the genset easily to move)
Open Unit
Exhaust Silencer, Critical Kit
Open Style
Cooling System
Overall Size, L W H
Block Heater
(recommended for ambient temperatures below 0 )
mm
2645 730
Weight(radiator model),net,Kg
1630
1680
Fuel System
Auxiliary Fuel Pump
Soundproof Style
Overall Size, L W H
Weight(radiator model),net,Kg
mm
Electrical System
Battery Charger, Equalize/Float Type
NOTE :
This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
Anti-Condensation Heater
DISTRIBUTED BY: